SAW Bandpass Filter 201167B
3. Specifications
Fo = 70.0 MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Minimum
Typical
70.0
23.0
12.7
13.0
13.9
0.8
Maximum
70.04
25.0
-
Center Frequency
MHz
dB
69.97
Insertion Loss
-
1dB Bandwidth
MHz
MHz
MHz
dB
-
3dB Bandwidth
12.9
13.1
14.0
1.0
40dB Bandwidth
-
-
-
-
Amplitude Ripple (Fo +/- 6.2 MHz)
Group Delay Variation (Fo +/- 6.2 MHz)
Absolute Delay
nsec
usec
50
100
3.11
3.2
Relative Attenuation
at 30.0 ~ 62.9 MHz
dB
dB
45.0
27.0
27.0
45.0
-
50.0
30.0
30.0
50.0
-72
-
-
-
-
-
at 62.9 ~ 63.1 MHz
at 76.9 ~ 77.1 MHz
dB
at 77.1 ~ 100 MHz
dB
Temperature Coefficient of Frequency
ppm/°C
Notes :
1) All specifications are based on the matching schematic shown below
2) All specifications are measured by Agilent Network analyzer and full 2 port calibration at room temperature
3) All attenuation measurements are measured relative to insertion loss
I T F Co., Ltd.
Part No.
Rev. Date
Rev.
201167B
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2004-05-31
2/5
NM3004-CS03