■ 3291, 3293 Specifications (accuracy at 23˚C±5˚C (73˚F±9˚F), 80% RH or less)
Pocket Size Clamp On Design
Fits perfectly into a shirt pocket.
3291
3293
Load
Leak and load
Measurable
conductor size
ø30mm (1.18")max.
ø24mm (0.94")max.
Compact design for superior
portability
❏
True RMS
Rectification
AC600Vrms
AC300Vrms
Max. rated voltage to earth
Measurement Range
•Auto Range switching
30mA/300mA/
60A/600A/1000A
6A/60A/600A/1000A
•Zero-suppress at 5 counts
±1.5%rdg. ±5dgt. (50Hz to 60Hz),
±5%rdg. ±5dgt. (1mA to 2.70mA)
filter OFF: ±2.0%rdg. ±5dgt. (45 to 66Hz),
Accuracy
filter ON: fc=180Hz
3291
±3.0%rdg. ±5dgt. (66 to 400Hz)
Actual Size
(Add±1%rdg. for when using 60A on the 3293)
1 Year (or opening and closing of the sensor 10,000 times)
Guaranteeed Accuracy Period
Accuracy Guaranteed
Measurements
Minimum 1.00mA
Minimum 5.40A
(Add±1%rdg. for readings of 0.270 to 0.540A )
2.8 max (1.6 max when current exceeds 600A)
Crest factor
Max. 1.5s
Response Time
(Refers to time required to achieve 90% of accuracy specifications)
Approx. 2 times/second (Bar graph: Approx. 4 times/second)
Add (0.05 x accuracy specifications)/°C (at 0°C to 40°C)
Display Refresh Rate
Temperature Coefficient
Effect of
Conductor Position
Effect of External
Magnetic Field
within ±0.1% (at or below 6A range)
within ±5.0%
within ±5.0% (at or below 60A range)
Max 7.5mA (within a 400A/m
not defined
magnetic field, at or below 6A range)
Display hold, maximum value hold (hold bar graph position),
reversible LCD display, backlight, auto power off, auto power
on when jaws are open, battery level indication
Other Functions
0°C to 40°C/32°F to 104°F, 80%rh max. (no condensation)
-10°C to 50°C/14°F to 122°F, 80%rh max. (no condensation)
Usage Environment
Storage Environment
EN61010-2-032
Type A current sensor,
CAT III 300V, EN61326
EN61010-2-032
Type A current sensor,
CAT III 600V, CAT IV 300V, EN61326
Standards
Rated Voltage and
DC3V, 25mVA
maximum rated power
Power Supply and
max. continuous use
Button type lithium battery (CR2032) x 1,
Approx. 10 hours (continuous, no load)
50W×136H×26Dmm, 90g
50W×130H×26Dmm, 120g
1.97"× 5.12" × 1.02", 4.2 oz.
Dimensions and mass
1.97"×
5.35" H
×
1.02" D, 3.2 oz.
Convenient portable case
Soft case protects the instrument inside toolboxes.
❏
Included soft case protects the
i n s t r u m e n t a n d a t t a c h e s
conveniently to your belt.
Carrying Case Model 9757
(included
Attaches to belt
Inside toolboxes
)
Bundled Accessories: Carrying Case 9757 x 1, Wrist strap x 1, Button type lithium battery (CR2032 - test use only) x 1, Instruction Manual x 1,
Basic Operation Sticker x 1
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
DISTRIBUTED BY
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: info-sh@hioki.cn
Beijing Office :
HEAD OFFICE :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: info-bj@hioki.cn
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
Guangzhou Office :
HIOKI USA CORPORATION :
Room 303, Profit Plaza, No.76, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: info-gz@hioki.cn
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
All information correct as of Jul. 12, 2007. All specifications are subject to change without notice.
3291sE1-77M-20P Printed in Japan