SAW Bandpass Filter 201168B
3. Specifications
Fo = 70.0 MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Minimum
Typical
70.0
30.0
24.4
24.6
25.5
0.8
Maximum
70.05
32.0
-
Center Frequency
MHz
dB
69.95
Insertion Loss
-
1dB Bandwidth
MHz
MHz
MHz
dB
24.0
3dB Bandwidth
24.5
24.7
26.0
1.0
40dB Bandwidth
-
-
-
-
Amplitude Ripple (Fo +/- 12.0 MHz)
Group Delay Variation (Fo +/- 12.0 MHz)
Absolute Delay
nsec
usec
50
100
3.18
3.2
Relative Attenuation
at 30.0 ~ 57.1 MHz
dB
dB
40
27
27
40
-
45
30
30
45
-72
-
-
-
-
-
at 57.1 ~ 57.3 MHz
at 82.7 ~ 82.9 MHz
dB
at 82.9 ~ 100.0 MHz
dB
Temperature Coefficient of Frequency
ppm/°C
Notes :
1) All specifications are based on the matching schematic shown below
2) All specifications are measured by Agilent Network analyzer and full 2 port calibration at room temperature
3) All attenuation measurements are measured relative to insertion loss
I T F Co., Ltd.
Part No.
Rev. Date
Rev.
201168B
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2004-06-18
2/5
NI2051-CS04