SAW Bandpass Filter 205101B
Electrical Specification
Fc = 70.0MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Minimum
Typical
70.0
5.0
Maximum
Center Frequency at room temp.
Insertion Loss
MHz
dB
69.955
70.044
-
6.0
3dB Bandwidth
MHz
MHz
usec
usec
0.030
0.035
0.170
15
-
40dB Bandwidth
-
-
-
0.200
Absolute Group Delay at Fc
Group Delay Variation at 3dB
Relative Attenuation
-
-
5
0.3 MHz
70.2 MHz
71.0 MHz
…
…
…
69.8 MHz
71.0 MHz
75.0 MHz
50
35
50
55
40
55
dB
-
-
Temperature Coefficient of Frequency
ppm/°C2
-
-0.03
Notes :
1) All specifications are based on the matching schematic shown below, measured by Agilent Network analyzer and
full 2 port calibration.
2) All attenuation measurements are measured relative to insertion loss
Part No.
Rev. Date
Rev.
205101B
I T F Co., Ltd.
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2004-07-14
2/7
NR3006-AS32