转到网站首页
转为中文步骤:
1、请用电脑端360浏览器打开本页地址,如您电脑未安装360浏览器,请点这里下载;
2、点击360浏览器右上角的翻译插件,如右图红圈中所示:
3、点击所弹出窗口里的右下角的按钮 “翻译当前网页”;
4、弹窗提示翻译完毕后关闭弹窗即可;
2003  
USB1.1 Interface Support  
3912-20 COMMUNICATION BASE  
Complete with LCD for Checking Data and Making Settings in the Field  
USB Interface for Connecting the Data Logger Series to a PC  
3632-20 TEMPERATURE  
LOGGER  
Waterproof with built-in sensor  
-20.0˚C to 70.0˚C  
3638-20 LEAK LOGGER  
For measuring leak current on two  
channels  
100.0 mA/1000 mA AC  
(clamp sensor sold separately)  
3633-20 TEMPERATURE  
LOGGER  
Separate external sensor  
-40.0˚C to 180.0˚C  
3639-20 PULSE LOGGER  
For cumulative pulse  
measurement for a precipitation  
gauges, flow gauge, etc.  
3634-20 INSTRUMENTATION  
LOGGER  
For measuring typical  
instrumentation signals  
DC 20.00 mA  
3640-20 LUX LOGGER  
For illumination measurement  
2000 lx to 200000 lx  
3635-24/-25/-26  
VOLTAGE LOGGER  
-24: DC ± 500.0 mV  
-25: DC ± 5.000 V  
-26: DC ± 50.00 V  
3641-20 HUMIDITY LOGGER  
Alternates recording of  
temperature and humidity on  
two channels  
-40˚C to 85.0˚C  
0.0%rh to 100.0%rh  
3636-20 CLAMP LOGGER  
For measuring alternating  
current on two channels  
50.00/500.0 A AC  
3645-20 VOLTAGE LOGGER  
With preheat function  
DC ± 50.00 mV to ± 50.00 V  
(clamp sensor sold separately)  
3637-20 AC VOLTAGE  
LOGGER  
AC 600.0 V  
3912-20  
Compatible with the USB 1.1 interface  
Equipped with an LCD display that makes it  
easy to check collected data and change  
settings in the field  
Clock backup when battery needs  
replacement (approximately 12 hours)  
Same easy-to-use interface, like the current  
3911-20  
Improved reliability in data retention  
Does not consume battery power while  
connected to a PC  
Integrates with PC software for the 3911-20  
(Operates with both the 3911-20 and the 3912-20  
)
http://www.hioki.co.jp/  
HIOKI company overview, new products, environmental considerations and  
other information are available on our website.  
Select Either USB or the RS-232C as the PC Communication Interface for the Data Logger Series  
The USB-compatible 3912-20 has been added as a  
communication base for the flexible Data Logger  
Series of compact loggers for measuring information  
such as temperature, humidity, instrument signals,  
load current, leak current, voltage, pulse signals, and  
illumination. There are now two types of  
Logger Series: the RS-232C-compatible 3911-20  
and the newly released USB 1.1-compatible 3912-  
20. The communication bases have proven popular  
for their ability to facilitate the collection of data in  
the field. Because the 3912-20 is equipped with an  
LCD, it also allows the user to easily check data and  
change settings.  
communication bases (which are used to download  
data recorded by a Data Logger to a PC) for the Data  
Function Specifications  
Specifications of Bundled PC Communication Software  
Display  
Dot matrix LCD (128 × 64 dots)  
: Windows 98/Me/2000/XP (for DOS/V)  
Supported OS  
Communication  
combinations  
PC 3912-20  
Clock, recording interval, start control, recording method,  
: Graph display (16 channels maximum, two  
Dis p la y  
comment  
3912-20 PC  
Collected data (16 channels maximum: 256,000 data  
elements maximum)  
cursors, enlarge/reduce/scroll possible), measurement data list  
display, data count, average value, maximum value, minimum  
3912-20 Logger Clock, recording interval, start control, recording method,  
comment  
value, recording date and time  
: Graph printing (16  
Printing  
Logger 3912-20 Collected data (16,000 data elements maximum)  
channels maximum, printing between cursors), measurement  
data list, data count, average value, maximum value, minimum  
Communication  
method  
3912-20 Logger Infrared optical communications (synchronous serial  
communications, three lines)  
value, recording date and time  
: Proprietary  
File formats  
3912-20 PC  
USB 1.1 (full speed: 12 Mbps)  
*
CSV format: A  
format (binary code), text save (CSV format)  
Communication  
speed  
3912-20 Logger Approximately 250 data elements/second (reference value)  
comma-delimited text format that can be directly read by Excel  
3912-20 PC  
Approximately 16,000 data elements/second (reference  
value)  
Cable  
USB cable (provided, approximately 1m)  
Recording  
capacity  
16 channels maximum (16,000 data elements maximum × 16 channels)  
Analysis and data processing data  
on computer  
General Specifications  
Use either the 3912-20 COMMUNICATION BASE  
(USB) or the 3911-20 COMMUNICATION BASE  
(RS-232C) for communication (transferring data and  
settings) between a Data Logger and a PC.  
The 3912-20 can collect up to 16,000 data elements for  
up to 16 channels; when installed in the field, the 3912-  
20 can collect data from multiple devices and then send  
all of the data to a PC for analysis and processing.  
: Yes (Prevents loss of stored data during battery replacement; clock is  
Backup  
backed up by a two-layer capacitor for approximately 12 hours) (reference value)  
: Approximately 3 months or more (when idle)  
Battery life  
: Approximately 50 times (sending 16,000 data elements × 16  
Communication  
-20  
channels from Data Logger 3912 PC)  
4 alkaline dry cells (LR03)  
: 1.5V batteries ×  
Power supply  
: 0.4 VA  
Maximum rated power  
: Approx. W68.5 mm (2.70 ") × H128 mm (5.04 ") × D36 mm  
Dimensions  
(1.42 ") (expluding protrusions)  
: 180g(6.35 oz.) (including batteries)  
Mass  
: Indoors, at altitudes of up to 2000 m (6562 -ft.)  
Locations for use  
: 0˚C(32˚F) to 40˚C(104˚F), up to 80%rh  
Operating temperature range  
(with no condensation)  
: -10˚C(14˚F) to  
Storage temperature range  
50˚C(122˚F), up to 80%rh (with no condensation)  
:
Applicable standards  
EMC EN61326-1:1997+A1:1998 Safety EN61010-1:2001 overvoltage category I  
(expected overvoltage of 30 V), pollution degree 2  
: Operation  
Accessories  
Guide, USB cable, PC communication software (CD-R), alkaline batteries  
(LR03) × 4  
Communication between the  
3912-20 and a Data Logger  
Data Logger  
Communication between the  
3912-20 and a PC  
3912-20  
3912-20  
PC communication software  
DISTRIBUTED BY  
USB cable  
Install in a fixed location when using  
infrared optical communication  
ASM GmbH  
Am Bleichbach 18 - 22  
HEAD OFFICE :  
85452 Moosinning  
81 Koizumi, Ueda, Nagano, 386-1192, Japan  
TEL +81-268-28-0562 / FAX +81-268-28-0568  
E-mail: os-com@hioki.co.jp  
HIOKI USA CORPORATION :  
6 Corporate Drive, Cranbury, NJ 08512 USA  
TEL +1-609-409-9109 / FAX +1-609-409-9108  
E-mail: hioki@hiokiusa.com  
All information correct as of Feb. 20, 2003. All specifications are subject to change without notice.  
I3912E1-32M-03P Printed in Japan