Select Either USB or the RS-232C as the PC Communication Interface for the Data Logger Series
The USB-compatible 3912-20 has been added as a
communication base for the flexible Data Logger
Series of compact loggers for measuring information
such as temperature, humidity, instrument signals,
load current, leak current, voltage, pulse signals, and
illumination. There are now two types of
Logger Series: the RS-232C-compatible 3911-20
and the newly released USB 1.1-compatible 3912-
20. The communication bases have proven popular
for their ability to facilitate the collection of data in
the field. Because the 3912-20 is equipped with an
LCD, it also allows the user to easily check data and
change settings.
communication bases (which are used to download
data recorded by a Data Logger to a PC) for the Data
Function Specifications
Specifications of Bundled PC Communication Software
Display
Dot matrix LCD (128 × 64 dots)
ꢁ
ꢁ
: Windows 98/Me/2000/XP (for DOS/V)
Supported OS
Communication
combinations
PC → 3912-20
Clock, recording interval, start control, recording method,
: Graph display (16 channels maximum, two
Dis p la y
comment
3912-20 → PC
Collected data (16 channels maximum: 256,000 data
elements maximum)
cursors, enlarge/reduce/scroll possible), measurement data list
display, data count, average value, maximum value, minimum
3912-20 → Logger Clock, recording interval, start control, recording method,
comment
ꢁ
value, recording date and time
: Graph printing (16
Printing
Logger → 3912-20 Collected data (16,000 data elements maximum)
channels maximum, printing between cursors), measurement
data list, data count, average value, maximum value, minimum
Communication
method
3912-20 ⇔ Logger Infrared optical communications (synchronous serial
communications, three lines)
ꢁ
value, recording date and time
: Proprietary
File formats
3912-20 ⇔ PC
USB 1.1 (full speed: 12 Mbps)
*
CSV format: A
format (binary code), text save (CSV format)
Communication
speed
3912-20 ⇔ Logger Approximately 250 data elements/second (reference value)
comma-delimited text format that can be directly read by Excel
3912-20 ⇔ PC
Approximately 16,000 data elements/second (reference
value)
Cable
USB cable (provided, approximately 1m)
Recording
capacity
16 channels maximum (16,000 data elements maximum × 16 channels)
ꢁ Analysis and data processing data
on computer
General Specifications
Use either the 3912-20 COMMUNICATION BASE
(USB) or the 3911-20 COMMUNICATION BASE
(RS-232C) for communication (transferring data and
settings) between a Data Logger and a PC.
The 3912-20 can collect up to 16,000 data elements for
up to 16 channels; when installed in the field, the 3912-
20 can collect data from multiple devices and then send
all of the data to a PC for analysis and processing.
ꢁ
: Yes (Prevents loss of stored data during battery replacement; clock is
Backup
backed up by a two-layer capacitor for approximately 12 hours) (reference value)
ꢁ
ꢁ
: Approximately 3 months or more (when idle)
Battery life
: Approximately 50 times (sending 16,000 data elements × 16
Communication
-20
ꢁ
channels from Data Logger → 3912 → PC)
4 alkaline dry cells (LR03)
ꢁ
: 1.5V batteries ×
Power supply
ꢁ
: 0.4 VA
Maximum rated power
: Approx. W68.5 mm (2.70 ") × H128 mm (5.04 ") × D36 mm
Dimensions
ꢁ
(1.42 ") (expluding protrusions)
ꢁ
: 180g(6.35 oz.) (including batteries)
Mass
: Indoors, at altitudes of up to 2000 m (6562 -ft.)
Locations for use
ꢁ
: 0˚C(32˚F) to 40˚C(104˚F), up to 80%rh
Operating temperature range
ꢁ
(with no condensation)
: -10˚C(14˚F) to
Storage temperature range
ꢁ
50˚C(122˚F), up to 80%rh (with no condensation)
:
Applicable standards
EMC EN61326-1:1997+A1:1998 Safety EN61010-1:2001 overvoltage category I
ꢁ
(expected overvoltage of 30 V), pollution degree 2
: Operation
Accessories
Guide, USB cable, PC communication software (CD-R), alkaline batteries
(LR03) × 4
ꢁ Communication between the
3912-20 and a Data Logger
Data Logger
ꢁ Communication between the
3912-20 and a PC
3912-20
3912-20
PC communication software
DISTRIBUTED BY
USB cable
Install in a fixed location when using
infrared optical communication
ASM GmbH
Am Bleichbach 18 - 22
HEAD OFFICE :
85452 Moosinning
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
All information correct as of Feb. 20, 2003. All specifications are subject to change without notice.
I3912E1-32M-03P Printed in Japan