3
3273-50 to 3276 CLAMP ON PROBE
3273-50
3276
■ 3273-50 / 3276 Specifications (accuracy is guaranteed at 23±3˚C [73±5˚F] after the power has been on for 30 minutes)
3273-50
3276
Frequency bandwidth
Rise time
DC to 50 MHz (-3 dB) * See Fig. 1 on page 1.
DC to 100 MHz (-3 dB) * See Fig. 1 on page 1.
7 ns or less
3.5 ns or less
Continuous maximum
input range
30 Arms
30 Arms
* Frequency derating see Fig. 2 on page 1.
* Frequency derating see Fig. 2 on page 1.
Maximum peak current
value
Non-continuous 50 Apeak
0.1 V/A
Non-continuous 50 Apeak
Output voltage rate
Amplitude accuracy
0.1 V/A
±1.0% rdg. ±1 mV (0 to 30 Arms / DC, 45 to 66 Hz)
±2.0% rdg. (30 Arms to 50 Apeak / DC, 45 to 66 Hz)
±1.0% rdg. ±1 mV (0 to 30 Arms / DC, 45 to 66 Hz)
±2.0% rdg. (30 Arms to 50 Apeak / DC, 45 to 66 Hz)
2.5 mArms or less
(measured with 20 MHz bandwidth equipment)
2.5 mArms or less
(measured with 20 MHz bandwidth equipment)
Noise
Input impedance
* See Fig. 3 on page 1.
* See Fig. 3 on page 1.
Sensitivity temperature
characteristics
Within ±2%
Within ±2% (from 0 to 40 ˚C [32 to 104 ˚F] )
(At 50 Hz/30 Arms input, 0 to 40˚C [32 to 104˚F])
Maximum rated power
Power supply voltage
5.6 VA (Input within the maximum input range.)
±12 V ±0.5 V
5.3 VA (Input within the maximum input range.)
±12 V ±0.5 V
Operating temperature
and humidity
0 to 40˚C [32 to 104˚F] , 80% rh or less
(no condensation)
0 to 40˚C [32 to 104˚F] , 80% rh or less
(no condensation)
Storage temperature
and humidity
-10 to 50˚C [14 to 122˚F] , 80% rh or less
(no condensation)
-10 to 50˚C [14 to 122˚F] , 80% rh or less
(no condensation)
Effect of external
magnetic fields
Max. 20 mA (equivalent)
(DC and 60 Hz, Magnetic field of 400 A/m)
Max. 5 mA (equivalent)
(DC and 60 Hz, Magnetic field of 400 A/m)
Max. rated voltage to earth
Measurement conductor
300 V, CAT-I (insulated conductor)
Diameter max. 5 mm [0.20"]
300 V, CAT-I (insulated conductor)
Diameter max. 5 mm [0.20"]
Sensor: approx. 175(W)■18(H)■40(D) mm; 230 g
[6.89"(W)■0.71"(H)■1.57"(D), 8.1 oz.]
Termination unit: approx. 27(W)■55(H)■18(D) mm
[1.06"(W)■2.17"(H)■0.71"(D)]
Sensor: approx. 175(W)■18(H)■40(D) mm; 240 g
[6.89"(W)■0.71"(H)■1.57"(D), 8.5 oz.]
Termination unit: approx. 27(W)■55(H)■18(D) mm
[1.06"(W)■2.17"(H)■0.71"(D)]
Dimensions and mass
Sensor cable: approx. 1.5 m [59.06"] (BNC connector)
Power cable: approx. 1 m [39.37"]
Sensor cable: approx. 1.5 m [59.06"] (BNC connector)
Power cable: approx. 1 m [39.38"]
Cable length
Soft case ■1
Hard case■1
Supplied accessories
EN 61010-2-031: 1994, EN 61010-2-032: 1995
Measurement category I (anticipated transient overvoltage 1500 V), Measurement category I (anticipated transient overvoltage 1500 V),
EN 61010-2-032:2002
Safety
standards
Pollution Degree 2
Pollution Degree 2
Applicable
standards
EN 61326:1997+A1:1998+A2:2001
EN 61000-3-2: 2000
EN 61326:1997+A1:1998+A2:2001
EN 61000-3-2: 2000
EMC
EN 61000-3-3: 1995+A1:2001
EN 61000-3-3: 1995+A1:2001
■ Power supply plug
■ Sensor head
Connects to the FET probe power supply outlet of an oscilloscope
Composed of molded parts, ferrite and Hall
elements. The thin-film of the Hall element
especially improves detection sensitivity to realize
wider bands and high sensitivity monitoring.
or to the optional 3269 / 3272 power supply unit.
(Provided that connector type, pin assignment, voltage, and capacity rating
match, the 3273-50 to 3276 can be powered also from another source. For
operation safety, be sure to refer to the specifications to ensure an exact match.)
3273-50/3276 : approx. 175(W)■18(H)■40(D) mm, [6.89"(W)■0.71"(H)■1.57"(D)]
Power supply plug pin assignment (Plug as seen from the front)
1 : Not connected
2 : GND
3 : V- (-12V)
4 : V+ (+12V)
Maximum measurement conductor: dia. 5 mm [0.20"]
2
3
1
4
Power cable
(approx. 1 m [39.37"])
Sensor cable (approx. 1.5 m [59.06"])
* Connector type: LEMO inc./ FFA.0S.304.CLAC42Z
■
BNC output connector
Sensor cable (approx. 2 m [78.74"])
Can be connected directly to the BNC input of an
oscilloscope or level recorder or similar device.
3274/3275 : approx. 176(W)■69(H)■27(D) mm, [6.93"(W)■2.72"(H)■1.06"(D)]
Output voltage rate: 0.1 V/A (3273-50 / 3276)
0.01 V/A (3274 / 3275)
(Use only equipment with an input impedance of 1 MΩ or more.)
Maximum measurement conductor: dia. 20 mm [0.79"]