SAW Delay-Line 836D252
3. Specifications
Fo = 836.5 MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Minimum
Typical
836.5
32.0
45.0
89.5
0.8
Maximum
Center Frequency
MHz
dB
833.5
839.5
Insertion Loss
-
40.0
-
35.0
3dB Bandwidth
MHz
MHz
dB
-
-
30dB Bandwidth
Amplitude Ripple (Fo +/- 12.5 MHz)
-
1.0
100
10.1
-
Group Delay Variation (Fo +/- 12.5 MHz)
Absolute Delay
nsec
usec
-
20
9.9
30
-
10.02
35
Ultimate Rejection
dB
Temperature Coefficient of Frequency
ppm/°C
-94
-
Notes :
1) All specifications are based on the matching schematic shown below
2) All specifications are measured by Agilent Network analyzer and full 2 port calibration at room temperature
3) All attenuation measurements are measured relative to insertion loss
I T F Co., Ltd.
Part No.
Rev. Date
Rev.
836D252
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2004-07-08
ND1003-CS02