SAW Bandpass Filter F1G12
Specifications
Fc = 1100.0MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Minimum
Typical
1100.0
4.0
Maximum
Center Frequency ( Fc )
MHz
dB
-
-
-
-
-
-
-
5.0
1.5
-
Insertion Loss (Fc +/- 10 MHz)
Amplitude Ripple (Fc +/- 10 MHz)
Absolute Group Delay at Fc
dB
0.8
nsec
40
Group Delay Variation (Fc +/- 10 MHz)
VSWR (Fc +/- 10 MHz)
nsec
20
-
1.5
2.0
Relative Attenuation
…
~ Fc - 50 MHz
dB
30
30
40
40
-
-
Fc + 50 MHz ~
…
Temperature Coefficient of Frequency
ppm/°C
-
-32
Notes :
1) All specifications are based on the matching schematic shown below, measured by Agilent Network analyzer and
full 2 port calibration.
2) Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing
tolerances
3) All attenuation measurements are measured relative to insertion loss
Part No.
Rev. Date
Rev.
F1G12
I T F Co., Ltd.
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2004-11-01
2/7
NR1008-AS02