SAW Bandpass Filter F1G56
Specifications
Minimum
Typical
1575.42
1.1
Maximum
Unit
MHz
dB
Center Frequency ( Fc )
-
-
-
-
-
Insertion Loss (Fo +/- 1 MHz)
Amplitude Ripple (Fo +/- 1 MHz)
VSWR (Fo +/- 1 MHz)
1.6
0.8
1.8
0.1
dBp-p
1.2
Relative Attenuation
D.C. ~ 1400 MHz
1400 ~ 1490 MHz
1490 ~ 1520 MHz
( 1500 MHz )
20.0
25.0
30.0
(35.0)
30.0
25.0
23.0
30.0
35.0
(44.0)
42.0
30.0
-
-
-
-
-
-
dB
1625 ~ 1635 MHz
1800 ~ 3000 MHz
℃
Temperature Range (Operational)
Input RF Power (Fo +/- 1 MHz)
Input/Output Impedance
-40
25
50
85
10
dBm
Ohms
Notes :
1) All specifications are based on the matching schematic shown below, measured by Agilent Network analyzer and
full 2 port calibration.
2) Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing
tolerances
3) All attenuation measurements are measured relative to insertion loss
Part No.
Rev. Date
Rev.
F1G56
I T F Co., Ltd.
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2007-07-13
NC7001-AS02
2/7