Sync'n Go® -- Portable Precision Frequency Reference
SYNC-10.00MHz.
RoHS
Pb
Compliant
FEATURES:
APPLICATIONS:
• Stand Alone 10.00MHz Portable Precision Frequency Reference
• Ideally suited as an in-field Calibrated Precision 10.00MHz reference
- World Wide Capability
for trouble shooting or tuning hardware and Base Station related
• Built-in Stratum-III stability, 10.00MHz Signal tuned into 50Ω's • Synchronization equipment
circuitry providing dynamic sync capability, enabling Calibration to a known
source such as; a GPS Tracked 10.00MHz reference/10.00MHz Rubidium
Source/10.00MHz OCXO based reference
• Reference source for lab use
• Reference source to drive frequency counters and other timing related
hardware or instruments
• Integrated re-chargeable batteries to provide true stand-alone capability in the field • Precision Portable reference for inspection of in-field wireless
• Once sync'd; guaranteed ±300 ppb stability over 0ºC to 60ºC
• Pocket Size - 3.50" * 1.50" * 1.00"; machined aluminum durable enclosure
• Accompanied with a Universal AC-DC Charger
transmitters
• Continuously operable at full charge for 10-hours
STANDARD SPECIFICATIONS:
Parameter
Input Reference Frequency for Sync
Output Reference Frequency
Operable Operating Range
Synchronization accuracy
Frequency Drift post sync
(25ºC ± 10ºC)
Description
Value / Units
MHz
10.00
10.00
0ºC to +60ºC
±5.00
MHz
ppb
ppb Typical
±25.00
Frequency Drift post sync
(25ºC ± 20ºC)
±50.00
ppb Typical
Frequency Accuracy Over the
operating Temperature Range
Load Impedance
< ±100
±300
50
ppb Typical; Post Sync
ppb Maximum; Post Sync
Ω
Charging Time
Stand Alone operational time with
full charge
4.00
10.00
Hours maximum
Hours minimum
Phase Noise @ 10.00MHz Carrier
100
1,000
10,000
100,000
1,000,000
Hz offset
Hz offset
Hz offset
Hz offset
Hz offset
-120
-140
-150
-155
-155
dBc/Hz typical
dBc/Hz typical
dBc/Hz typical
dBc/Hz typical
dBc/Hz typical
Output amplitude
ALL Harmonics
rms jitter
6.0
-30
< 0.50 ps
dBm minimum
dBc maximum
12kHz to 20MHz BW from the carrier
PACKAGE OUTLINE
Visit www.abracon.com for Terms & Conditions of Sale Revised: 10.02.11
30332 Esperanza, Rancho Santa Margarita, California92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
ABRACON IS
ABRACON IS
ISO9001:2008
CERTIFIED
CERTIFIED
Sync'n Go® -- Portable Precision Frequency Reference
SYNC-10.00MHz.
RoHS
Pb
Compliant
OPERATIONAL MANUAL
Charge:
1) Plug 5V charger (or PC or any other USB power source) into a mini-USB port
2) "Bat" LED may turn yellow for a moment to signal that an internal battery is evaluated
3) "Bat" LED will flash green to signal that the battery is being charged
4) "Bat" LED will display solid green when the battery is fully charged
Synchronization:
1) Connect a 10MHz standard to the "Ref In" input
2) Press "Synchronize"
3) "Lock" LED will turn-on yellow to signal that "Sync N Go" is evaluating the standard
4) If the reference is stable, the "Lock" LED will turn green to signal that the signal is
locked and that the reference information is stored
5) If the reference is not found or it is outside a frequency range or it is not stable, the
"Lock" LED will flash red
6) If that occurs, the "Lock" LED turns-off and the "Sync N Go" goes into a sleep mode
Output ON (if battery charged):
1) Press "Power"
2) "ON" LED will turn green
3) "Sync N Go" will output a continuous RF signal on the "Out" connector
Output ON (if battery low):
1) Press "Power"
2) "ON" LED will turn green.
3) "Sync N Go" will output a continuous RF signal on the "Out" connector. At the same
time, "Bat" LED will slowly flash red.
Output ON (if battery is discharged):
1) Press "Power"
2) "Bat" LED will rapidly flash red for few seconds and "Sync N Go" will immediately go
back to sleep
Output OFF:
1) Press "Power"
2) "ON" LED turns off and the "Sync N Go" goes into a sleep mode
ATTENTION: Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component
failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization from
Abracon Corporation is required. Please contact Abracon Corporation for more information.
Designed & Manufactured in United States
For technical assistance, please contact: techsupport@abracon.com
Visit www.abracon.com for Terms & Conditions of Sale Revised: 10.02.11
30332 Esperanza, Rancho Santa Margarita, California92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
ABRACON IS
ABRACON IS
ISO9001:2008
CERTIFIED
CERTIFIED
相关型号:
SYNCMASTER170MP(ML17NS/ML17AS)
Monitor_ICs:AD9884AKS-140 ICS502M LM1881M ICS502M FST3125M NJM2248M STV6400D Z86129 NJM2509V SDA9400 VPC3230D-A0 PW364-S1675 AD5301B
ETC
©2020 ICPDF网 联系我们和版权申明