E-CV-S02A [ACCRETECH]

SURFCOM · CONTOURECORD Option;
E-CV-S02A
型号: E-CV-S02A
厂家: ACCRETECH    ACCRETECH
描述:

SURFCOM · CONTOURECORD Option

文件: 总20页 (文件大小:3633K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Nose Piece  
Applicable models S1500  
S1900  
S1910  
S2900  
S-NEX001  
Measuring application  
Model  
External view  
Applicable stylus  
Skid shape  
-
Remarks  
Skidless  
Front travel adjustment with  
adjustment screw  
DM44026  
All  
E-DT-SS01A pickup use only  
Applicable models  
FLEX-50  
S130  
S480  
S1400  
S1800  
S2800  
Measuring application  
Model  
External view  
Applicable stylus  
Skid shape  
Remarks  
General  
010 2501  
DM43801  
Tip skid  
Standard pickup built in  
010 2701  
32 mmR sapphire  
purpose  
Skidless  
9.1  
4
For protection  
For front travel adjustment  
010 2702*  
010 2703*  
All styluses  
-
Horizontal  
tracing of  
ordinary planes  
Double sided straddling skid  
Skid radius for horizontal  
tracking: 4.5 mm  
010 2501  
DM43801  
9.1  
8.4  
1
4.8  
Double sided straddling skid  
Position adjustment with stylus  
required  
010 2511  
DM43811  
Extra fine holes 010 2704  
8 mmR tool steel  
8 mmR tool steel  
8 mmR tool steel  
32 mmR sapphire  
32 mmR sapphire  
32 mmR sapphire  
0.8 mmR ruby  
1.8  
17.2  
010 2512  
DM43812  
Fine holes  
010 2705  
010 2706  
010 2707  
010 2708  
010 2709*  
010 2710*  
010 2711  
010 2722*  
010 2723  
010 2724  
010 2726  
Tip skid  
4.5  
5.2  
Thin groove  
tooth surfaces  
010 2512  
DM43812  
Double sided straddling skid  
Curved sur-  
faces  
010 2515  
DM43815  
20.3  
Sliding skid  
12  
010 2515  
DM43815  
Deep grooves  
20.3  
Double sided straddling skid  
Narrow  
deep grooves  
010 2515  
DM43815  
Tip skid  
20.3  
One sided straddling skid  
Magnification: 5,000 or more  
Position adjustment with stylus  
required  
010 2515  
DM43815  
R grooves  
2.5  
1.5  
Recording only  
Double sided straddling skid  
Skid position adjustment  
required  
Three types of skids provided  
for Φ 2 to 4,Φ 4 to 8, Φ 8 to 16  
Small round  
bars  
010 2501  
DM43801  
32 mmR sapphire  
32 mmR sapphire  
32 mmR sapphire  
32 mmR sapphire  
0.8 mmR ruby  
5.5  
4
010 2522  
DM43822  
Long holes  
Tip skid  
7.2  
Tip skid  
Position adjustment with stylus  
required  
Deep grooves  
in holes  
010 2525  
DM43825  
6
Double sided straddling skid  
Position adjustment with stylus  
required  
Extra  
deep grooves  
010 2526  
DM43826  
63.5  
Double sided straddling skid  
Magnification: 5,000 or more  
Position adjustment with stylus  
required  
Bottom surface  
of O-ring  
010 2525  
DM43825  
grooves  
* Indicates stylus/nose piece set DM43800 and 010 2640  
Standard Inventory Parts  
81  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Replaceable Roughness Profile Measuring Styli (Tip Radius 2 μm)  
Applicable models  
FLEX-50  
Model  
S130  
S1400  
S1500  
S1900  
S1910  
S480  
S1800  
S2800  
S2900  
S-NEX001  
Measuring application  
General purpose  
External view  
Specifications  
Remarks  
2 μmR,  
All orientations  
DM43801  
DM43802  
60° conical diamond,  
0.75 mN  
Horizontal tracing possible  
Standard accessory  
Fine wires,  
knife edges  
2 μmR,  
60° knife edge-shaped  
diamond,  
All orientations  
0.75 mN  
ø1.2  
ø2.7  
Medium fine holes  
2 μmR,  
60° conical diamond,  
0.75 mN  
2.6  
All orientations  
Horizontal tracing possible  
DM43809  
DM43811  
DM43812*  
15  
4.8)  
33.5  
5.7  
0.7)  
Extra fine holes,  
gear flank  
2 μmR,  
60° conical diamond,  
0.75 mN  
All orientations  
Horizontal tracing possible  
4.8  
Fine holes/  
thin grooves  
2 μmR,  
60° conical diamond,  
0.75 mN  
All orientations  
Horizontal tracing possible  
Hole bottom/conical  
surfaces  
2 μmR,  
60° conical diamond,  
0.75 mN  
All orientations  
Horizontal tracing possible  
DM43813  
DM43814*  
Corners/  
tooth surfaces  
2 μmR,  
60° conical diamond,  
0.75 mN  
All orientations  
Horizontal tracing possible  
Deep grooves/  
round grooves  
2 μmR,  
Downward measurement  
Large waveform distortion  
DM43815*  
60° conical diamond,  
0.8 mN  
Fine long holes  
Downward measurement  
Sensitivity: 1/2  
Magnification: x5000  
Large waveform distortion  
2 μmR,  
60° conical diamond,  
3 mN  
DM43821  
DM43822*  
DM43824  
Low magnification,  
long holes  
2 μmR,  
60° conical diamond,  
3 mN  
Downward measurement  
Sensitivity: 1/2  
Magnification: x20000  
Low magnification,  
corners  
2 μmR,  
60° conical diamond,  
4 mN  
Downward measurement  
Sensitivity: 1/2  
Magnification: x20000  
Deep groove  
corners  
2 μmR,  
60° conical diamond,  
4 mN  
Downward measurement  
Sensitivity: 1/2  
Magnification: x10000  
DM43827  
DM43825  
Deep hole grooves,  
O-ring groove bottom  
surfaces  
Downward measurement  
Sensitivity: 1/2  
Magnification: x20000  
Large waveform distortion  
2 μmR,  
60° conical diamond,  
3.4 mN  
Extra deep  
grooves  
Downward measurement  
Sensitivity: 1/2  
Magnification: x5000  
Large waveform distortion  
2 μmR,  
60° conical diamond,  
4 mN  
DM43826  
DM43800  
Nosepiece  
010 2702, 010 2703, 010 2709,  
010 2710, 010 2722  
Stylus  
DM43812, DM43814,  
DM43815, DM43822  
2 μmR  
2 μmR  
Stylus set  
E-DT-SS01A pickup use only  
Nosepiece DM44026  
Stylus  
DM43801, DM43811,  
DM43812, DM43814,  
DM43815, DM43822  
DM43900  
* Indicates stylus/nose piece set DM43800. The value of measuring force is when E-DT-S03A/E-DT-SE19A are mounted.  
Standard Inventory Parts  
82  
TOKYO SEIMITSU  
Replaceable Roughness Profile Measuring Styli (Tip Radius 5 μm)  
Applicable models  
FLEX-50  
Model  
S130  
S1400  
S1500  
S1900  
S1910  
S480  
S1800  
S2800  
S2900  
S-NEX001  
Measuring application  
General purpose  
External view  
Specifications  
Remarks  
5 μmR,  
90°conical diamond,  
All orientations  
010 2501  
Horizontal tracing possible  
All orientations  
4 mN  
Fine wires,  
knife edges  
5 μmR,  
90°knife edge-shaped  
diamond, 5 mN  
010 2502  
Medium fine  
holes  
5 μmR,  
All orientations  
Horizontal tracing possible  
010 2509  
010 2511  
010 2512*  
010 2513  
010 2514*  
90°conical diamond,  
4 mN  
15  
Extra fine holes,  
gear flank  
5 μmR,  
90°conical diamond,  
4 mN  
All orientations  
Horizontal tracing possible  
0.5  
Fine holes/  
thin grooves  
5 μmR,  
90°conical diamond,  
4 mN  
All orientations  
Horizontal tracing possible  
Hole bottom/  
conical surfaces  
75°  
5 μmR,  
90°conical diamond,  
4 mN  
All orientations  
Horizontal tracing possible  
6.1  
Corners/  
tooth surfaces  
5 μmR,  
60°conical diamond,  
4 mN  
All orientations  
Horizontal tracing possible  
Deep grooves/  
round grooves  
5 μmR,  
90°conical diamond,  
5 mN  
Downward measurement  
Large waveform distortion  
010 2515*  
Gear tooth  
profiles,  
thread flank  
5 μmR,  
90°conical diamond,  
4 mN  
7
010 2518  
Magnification: x10000  
Fine long holes  
Downward measurement  
Sensitivity: 1/2  
Magnification: x5000  
Large waveform distortion  
5 μmR,  
90°conical diamond,  
5 mN  
010 2521  
010 2522*  
010 2524  
010 2527  
40.7  
Low magnification,  
long holes  
5 μmR,  
90°conical diamond,  
5 mN  
Downward measurement  
Sensitivity: 1/2  
Magnification: x20000  
Low magnification,  
corners  
5 μmR,  
60°conical diamond,  
5 mN  
Downward measurement  
Sensitivity: 1/2  
Magnification: x20000  
Deep groove  
corners  
Downward measurement  
Sensitivity: 1/2  
Magnification: x10000  
Large waveform distortion  
5 μmR,  
60°conical diamond,  
8 mN  
Nosepiece  
010 2702, 010 2703, 010 2709,  
010 2710, 010 2722  
Stylus  
5 μmR  
Stylus set  
010 2640  
010 2512, 010 2514,  
010 2515, 010 2522  
* Indicates stylus/nose piece set 010 2640. The value of measuring force is when E-DT-S01A/E-DT-SE18A are mounted  
Standard Inventory Parts  
83  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Replaceable Roughness Profile Measuring Styli  
Applicable models  
FLEX-50  
Model  
S130  
S1400  
S1500  
S1900  
S1910  
S480  
S1800  
S2800  
S2900  
S-NEX001  
Measuring application  
External view  
Specifications  
Remarks  
Soft materials  
All orientations  
10 μmR,  
90° conical diamond,  
0.75 mN  
Horizontal tracing possible  
Specifications are for when  
E-DT-S02A is mounted  
010 2508  
Deep hole grooves,  
bottom surface of  
Oring groove  
Downward measurements  
Sensitivity: 1/2  
Magnification: x20000  
Large waveform distortion  
10 μmR,  
90° conical diamond,  
8 mN  
010 2525  
Extra deep grooves  
Downward measurements  
Sensitivity: 1/2  
Magnification: x5000  
Large waveform distortion  
10 μmR,  
90° conical diamond,  
8 mN  
010 2526  
Bottom surface  
of holes  
Magnification: x5000  
Large waveform distortion  
Dedicated connecting rod  
used  
5 μmR,  
90° conical diamond,  
8 mN  
010 2541  
High  
magnification  
measurement  
All orientations  
1 μmR,  
60° conical diamond,  
0.75 mN  
Horizontal tracing possible  
Specifications are for when  
E-DT-S04A is mounted.  
010 2506  
010 2528  
High  
magnification  
contour profiles  
Downward measurements  
Sensitivity: 1/2  
Magnification: x10000  
For E-DT-S01A, -S03A  
1 μmR,  
60° conical diamond,  
8 mN  
* The value of measuring force is when E-DT-S01A/E-DT-SE18A are mounted  
Standard Inventory Parts  
Replaceable Waviness Profile Measuring Styli  
Applicable models  
FLEX-50  
Model  
S130  
S1400  
S1500  
S1900  
S1910  
S480  
S1800  
S2800  
S2900  
S-NEX001  
Measuring application  
External view  
Specifications  
Remarks  
Steps  
250 μmR,  
60° conical saphire,  
7.2  
010 2504  
All orientations  
5 mN  
Waviness  
Φ 1.6, ruby,  
4 mN  
7.2  
010 2505  
010 2510  
010 2520  
010 2523  
All orientations  
All orientations  
Magnification: x5000  
Excluding E-DT-S03A/  
-SS01A/SE19A  
Extra fine hole  
profiles  
0.29  
Φ 0.5, tool steel,  
4 mN  
Fine long hole  
waviness  
Downward measuring  
Sensitivity: 1/2  
Magnification: x10000  
Φ 1.6, ruby,  
5 mN  
Large steps  
Downward measuring  
Sensitivity: 1/2  
Magnification: x25000  
250 μmR, sapphire,  
5 mN  
7.2  
* The value of measuring force is when E-DT-S01A/E-DT-SE18A are mounted  
Standard Inventory Parts  
84  
TOKYO SEIMITSU  
Pickups  
Applicable models  
FLEX-50  
S130  
S1400  
S1500  
S1900  
S1910  
S480  
S1800  
S2800  
S2900  
Measuring application  
Model  
External view  
Specifications  
Remarks  
All orientations  
Horizontal tracing possible  
2 μmR,  
60° conical diamond,  
0.75 mN  
Low measuring  
force  
Provided as standard S1500, S1900, S1910, S2900,  
E-DT-SS01A  
S-NEX001 (Specialized for Linear/NEX Series)  
With DM43801 stylus  
5 μmR,  
All orientations  
90° conical diamond,  
4 mN  
Horizontal tracing possible  
With 0102501 stylus  
General purpose E-DT-SS08A  
General purpose  
For S1500, S1900, and S2900 DX/SD types  
All orientations  
Horizontal tracing possible  
With 0102501 stylus  
5 μmR,  
90° conical diamond,  
4 mN  
E-DT-S01A  
E-DT-SE18A  
E-DT-SE18A: for S130A/S-FLEX50A  
Soft materials  
E-DT-S02A  
10 μmR,  
90° conical diamond,  
0.75 mN  
All orientations  
Horizontal tracing possible  
With 0102508 stylus  
Low measuring  
force  
All orientations  
2 μmR,  
60° conical diamond,  
0.75 mN  
Horizontal tracing possible  
Standard specifications  
With DM43801 stylus  
E-DT-S03A  
E-DT-SE19A  
9.1  
E-DT-SE19A: for S130A/S-FLEX50A  
High magnification  
1 μmR,  
All orientations  
60° conical diamond,  
0.75 mN  
Horizontal tracing possible  
With 0102506 stylus  
E-DT-S04A  
Non-continuous  
measurement  
All orientations  
5 μmR,  
90° conical diamond,  
4 mN  
Horizontal tracing possible  
Front travel: 110 to 120 μm  
Other specifications are same as for  
E-DT-S01A  
E-DT-S05A  
Grooves in holes  
Skidless measurement only  
Max. magnification: x10000  
Dedicated connecting rod required  
(010 2746)  
5 μmR,  
90° conical diamond,  
4 mN  
E-DT-S06A  
With 0102542 dedicated stylus  
Ultra deep  
5 μmR,  
grooves  
90° conical diamond,  
5 mN  
E-DT-S07A  
Stylus can not be replaced  
Max. magnification: x10000  
Sensitivity: 1/2  
2 μmR,  
60° conical diamond,  
4 mN  
Large waveform distortion  
E-DT-S122A  
Ultra long holes  
5 μmR,  
90° conical diamond,4 mN  
E-DT-S08A  
E-DT-S137A  
Stylus can not be replaced  
Max. magnification: x5000  
Sensitivity: 1/5  
2 μmR,  
60° conical diamond,4 mN  
High magnification  
Max. magnification: x500000  
Measuring force:0.2 mN  
With 016 2854 stylus  
E-DT-SH01A  
1 μmR, 90° conical diamond Included with E-DT-SA01A as standard  
1 μmR, 60° conical diamond  
0162854  
010 2567  
010 2210  
010 2211  
010 2212  
10 μmR, 60° conical diamond  
Stylus for  
E-DT-SH01A  
5 μmR, 60° conical diamond  
0.5 μmR, 60° conical diamond  
0.5 μmR, 90° 2.5 μm width  
knife edge, diamond  
010 2213  
23  
5 μmR,  
90° conical diamond  
10 mN,  
With 0102501 dedicated stylus  
DM42001: for S1400, S1800, S2800  
DM42011: for S480  
DM42001  
DM42011  
DM42012  
Thin pickup  
horizontal tracing possible  
Max. magnification: x5000 or less DM42020: for Linear Series/NEX Series  
DM42012: for models preceding S590A  
Used for horizontal tracing of  
crankshaft pins, journals,  
or other such parts.  
Pickup holder  
for thin pickup  
E-DH-S60A  
E-DT-SL12B  
123.6  
Measuring range: 300 μm  
Spot diameter: 2 μm  
Work distance: 4.5 mm  
Color confocal point type  
Light source: Halogen light bulb  
Life: 1000h  
Non-contact  
measurement  
Standard Inventory Parts  
85  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Replaceable Styli for S5000DX/S3000/SNEX  
Applicable models  
Name  
S5000DX/SD  
S3000A  
SNEX100  
Model  
External view  
Specifications  
Remarks  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
2 μmR,  
60° conical diamond,  
0.75 mN  
DM48505  
General purpose  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
S5000DX/SD standard  
accessory  
2 μmR,  
60° conical diamond,  
0.75 mN  
General purpose  
highly rigid  
stylus  
DM84071  
(Old model: DM48507)  
Stroke: 26 mm (S5000)  
24mm (S3000)  
10mm (S-NEX 100)  
For contour measurement  
only  
Highly rigid sty-  
lus for contours  
2X arm  
Φ 1 ruby ball,  
0.75 mN  
DM48508  
DM48509  
DM48511  
DM48742  
DM48513*1  
DM48514  
DM48515  
DM48588  
DM48774  
Stroke: 32.5 mm (S5000)  
30mm (S3000)  
12.5mm (S-NEX 100)  
For contour measurement  
only  
Highly rigid sty-  
lus for contours  
2.5X arm  
Φ 1 ruby ball,  
3.2 mN  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
2 μmR,  
60° conical diamond,  
0.75 mN  
Offset measure-  
ment stylus  
Stroke: 26 mm (S5000)  
24mm (S3000)  
10mm (S-NEX 100)  
For contour measurement  
only  
25 μmR,  
24° conical carbide,  
4 mN or less  
Offset measure-  
ment stylus  
2X arm  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
2 μmR,  
60° conical diamond,  
0.75 mN  
Small hole stylus  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
2 μmR,  
60° conical diamond,  
0.75 mN  
Extra small hole  
stylus  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
2 μmR,  
60° conical diamond,  
0.75 mN  
Deep hole stylus  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
5 μmR,  
30° conical diamond,  
0.75 mN  
Stylus for  
fine contours  
Stroke: 13 mm (S5000)  
12mm (S3000)  
5mm (S-NEX 100)  
For roughness and contour  
measurement  
2 μmR,  
60° knife edge-shaped  
diamond,  
Stylus for ridge/  
tooth tip mea-  
surement  
0.75 mN  
2 or less  
*1 Requires master ball calibration unit for small holes. *Special stylus will be studied and proposed in accordance with customer’s workpieces.  
Standard Inventory Parts  
86  
TOKYO SEIMITSU  
Replaceable Styli for S2000DX/SD  
Applicable models  
Name  
S2000DX/SD  
Model  
External view  
Specifications  
2 μmR,  
60° conical diamond,  
0.75 mN  
5 μmR,  
30° conical diamond,  
0.75 mN  
5 μmR,  
40° conical diamond,  
4 mN  
Remarks  
Standard accessory  
Stroke: 5 mm  
For roughness and contour measurement  
DM47501  
General purpose DM47508  
DM47548  
Stroke: 5 mm  
For roughness and contour  
measurement  
Stroke: 5 mm  
For roughness and contour  
measurement  
LH=65, LV=−14.35  
25 μmR,  
24° conical carbide,  
5 mN  
Standard accessory  
Stroke: 10 mm  
LH=130,  
LV=−21.5  
DM47513  
For contour measurement only  
138.5  
Contour stylus  
2X arm  
25 μmR,  
12° inclined carbide,  
7 mN or less  
Stroke: 10 mm  
For contour measurement only  
LH=130,  
LV=−21.5  
DM47525  
Stroke: 5 mm  
2 μmR,  
60° conical diamond,  
0.75 mN  
Offset measure-  
DM47504  
LH=65,  
LV=−14.5  
Offset: 13.5 mm  
For roughness and contour  
measurement  
ment stylus  
2 μmR,  
60° conical diamond,  
0.75 mN  
Stroke: 5 mm  
For roughness and contour  
measurement  
DM47505*1  
LH=65,  
LV=−5.025  
Small hole stylus  
2 μmR,  
Stroke: 5 mm  
DM47524  
60° conical diamond,  
0.75 mN  
For roughness measurement  
only  
LH=65,  
LV=−5.7  
2 μmR,  
60° conical diamond,  
3 mN or less  
Stroke: 10 mm  
For roughness and contour  
measurement  
Small hole stylus  
DM47546*1  
2X arm  
LH=65,  
LV=−5.025  
2 μmR,  
60° conical diamond,  
0.75 mN  
Stroke: 5 mm  
For roughness and contour  
measurement  
Extra small hole  
DM47506*1  
stylus  
LH=65,  
LV=−4.625  
2 μmR,  
Stroke: 5 mm  
DM47507  
60° conical diamond,  
0.75 mN  
For roughness and contour  
measurement  
LH=65,  
5 μmR,  
Stroke: 5 mm  
LV=−30.5  
DM47549  
90° conical diamond,  
4 mN  
For roughness and contour  
measurement  
Deep groove  
stylus  
2 μmR,  
60° conical diamond,  
2 mN or less  
Stroke: 5 mm  
For roughness and contour  
measurement  
LH=65,  
LV=−55.5  
DM47572  
General purpose  
stylus  
2X arm  
2 μmR,  
60° conical diamond,  
4 mN  
Stroke: 10 mm  
For roughness and contour  
measurement  
LH=130,  
LV=−15.5  
DM47547  
DM47523  
DM47595  
DM47551  
138.5  
2 μmR,  
60° conical diamond,  
0.75 mN  
Stroke: 5 mm  
For roughness measurement  
only  
LH=65,  
LV=−12.525  
Corner/tooth  
surface stylus  
Corner/tooth  
surface stylus  
2X arm  
2 μmR,  
60° conical diamond,  
4 mN or less  
Stroke: 10 mm  
For roughness measurement  
only  
130,  
−13.5  
2 μmR,  
60° knife edge-shaped  
diamond,  
Stylus for ridge/  
tooth tip mea-  
surement  
Stroke: 5 mm  
For roughness and contour  
measurement  
LH=65,  
LV=−8.35  
0.75 mN  
Stylus for wavi-  
ness measure- DM47540  
ment  
Stroke: 5 mm  
For contour (waviness)  
measurement  
Φ 2 ruby ball,  
0.75 mN  
LH=65,  
LV=−14.35  
*Requires master ball calibration unit for small holes. *Special stylus will be studied and proposed in accordance with customer’s workpieces.  
Standard Inventory Parts87  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Contour Styli  
*See page 90 to 91 for the details of stylus/arm for C1710/S1910.  
Stylus material: Cemented carbide  
Applicable models  
Measuring application  
General purpose  
C1600  
Model  
C1700  
S1800  
S1900  
External view  
d
3
L1  
60  
L2 Applicable arm  
Remarks  
DM45501*2  
DM45502  
DM45503  
DM45504 *2  
DM45505*  
DM45506  
DM45507 *2  
DM45508*  
DM45509  
DM45081  
DM45082  
DM45083*1  
DM45084*  
DM45085  
DM45086* *1  
DM45087  
DM45088  
DM45089*1  
DM45090  
DM45091  
DM45092*1  
52  
26  
13  
52  
26  
13  
52  
26  
13  
9
010 2804  
010 2800  
010 2801  
010 2804  
010 2800  
010 2801  
010 2804  
010 2800  
010 2801  
3
2
34  
21  
60  
34  
21  
60  
34  
21  
12  
7
General purpose  
3
ød  
Standard acces-  
sory  
3
L1  
L2  
24° conical, R0.025  
2
Edge line  
3
3
2
Small holes  
010 2802  
010 2802  
010 2802  
010 2802  
5
3.5  
12  
7
1.5  
9
Small hole twist  
Ordinary offset  
Helix surface offset  
High precision  
7
17  
5
L1  
L2  
65  
24°
conical, R0.025  
3.5  
12  
7
1.5  
9
25  
65  
5
Offset: 25 mm  
L1  
L2  
17  
12° angular, R0.025  
3.5  
12  
7
1.5  
9
25  
65  
5
Offset: 25 mm  
L1  
L2  
17  
24° conical, R0.025  
3.5  
1.5  
DM45522 *2  
DM45523  
DM45524  
DM45525 *2  
DM45526  
DM45527  
3
3
2
3
3
2
60  
34  
21  
60  
34  
21  
52  
26  
13  
52  
26  
13  
010 2804  
010 2800  
010 2801  
010 2804  
010 2800  
010 2801  
Φ 0.7 ruby ball  
Φ 1 ruby ball  
*Indicates stylus/arm set 010 2999  
*1:Requires master ball calibration unit for small holes. *2:Requires pickup holder joint  
Standard Inventory Parts  
88  
TOKYO SEIMITSU  
Contour Detectors and Arms  
*See page 90 to 91 for the details of stylus/arm for C1710/S1910.  
Applicable models  
Measuring application  
C1600  
Model  
C1700  
S1800  
S1900  
External view  
Applicable arm  
Remarks  
E-DT-CE02A  
E-DT-CE03  
C1600, S1800D/G  
Contour detector  
General purpose  
C1700DX/SD, S1900DX/SD  
DM45502  
DM45505  
DM45508  
DM45523  
DM45526  
010 2800  
Inner surface  
Small holes  
DM45503  
DM45506  
DM45509  
DM45524  
DM45527  
010 2801  
179  
DM45081  
to  
010 2802*  
DM45092  
Deep grooves  
DM45501  
DM45504  
DM45507  
DM45522  
DM45525  
Max. magnification: x50  
010 2744 pickup holder coupling  
required  
010 2804  
Provided with auxiliary weight  
Offset measurement  
DM45502  
DM45505  
DM45508  
DM45523  
DM45526  
Max. magnification: x100  
Offset: 50 mm  
Provided with auxiliary weight  
010 2805  
DM45502  
DM45505  
DM45508  
DM45523  
DM45526  
Max. magnification: x50  
Offset: 100 mm  
Provided with auxiliary weight  
010 2806  
DM45503  
DM45506  
DM45509  
DM45524  
DM45527  
179  
Max. magnification: x100  
Offset: 50 mm  
Provided with auxiliary weight  
010 2807  
Long items  
Max. magnification: x10  
Lever movement range: 100 mm  
Sensitivity: 1/2  
Provided with auxiliary weight  
010 2744 pickup holder coupling  
required  
DM45501  
DM45504  
DM45507  
DM45522  
DM45525  
010 2808  
Long holes  
DM45503  
DM45506  
DM45509  
DM45524  
DM45527  
Max. magnification: x25  
Lever movement range: 100 mm  
Sensitivity: 1/2  
010 2810  
010 2999  
Provided with auxiliary weight  
Stylus : DM45505, DM45508,  
DM45084, DM45086  
Arms : 010 2802, 010 2805  
Arm/stylus set  
Standard Inventory Parts89  
*Indicates stylus/arm set 010 2999  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Contour Styli  
Stylus material: Cemented carbide  
Applicable models  
Measuring application  
General purpose  
C1710  
Model  
C2600  
C2700  
S1910  
External view  
S2800  
S2900  
d
3
L1  
60  
L2 Applicable arm  
Remarks  
DM45501  
DM45502  
52 DM45531  
26 DM45528  
3
34  
DM45503  
DM45504  
DM45505*  
DM45506  
DM45507  
DM45508*  
DM45509  
2
3
3
2
3
3
2
21  
60  
34  
21  
60  
34  
21  
13 DM45529  
52 DM45531  
26 DM45528  
13 DM45529  
52 DM45531  
26 DM45528  
13 DM45529  
General purpose  
ød  
Standard accessory:  
DM45505  
L1  
L2  
24° conical, R0.025  
Edge line  
Small holes  
7
DM45510  
DM45511  
DM45512*1  
12  
8
9
Measuring force:  
10 mN or less  
DM45530 Deflection:  
5
Approx. 1.5 μm for  
10 mN  
4.5 1.5  
Small hole twist  
7  
DM45513*  
DM45514  
12  
8
9
5
Measuring force:  
10 mN or less  
DM45530 Deflection:  
17  
L1  
L2  
65  
Approx. 1.5 μm for  
10 mN  
DM45515* *1  
4.5 1.5  
24° conical, R0.025  
Ordinary offset  
Helix surface offset  
High precision  
DM45516  
DM45517  
DM45518*1  
DM45519  
DM45520  
DM45521*1  
12  
8
9
5
25  
Measuring force:  
10 mN or less  
DM45530 Deflection:  
65  
Approx. 3 μm for  
10 mN  
L1  
L2  
17  
4.5 1.5  
12° angular, R0.025  
12  
8
9
5
25  
Measuring force:  
10 mN or less  
DM45530 Deflection:  
65  
Approx. 3 μm for  
10 mN  
L1  
L2  
17  
4.5 1.5  
24° conical, R0.025  
ø3  
21  
DM45580  
DM45583  
3
21  
13 DM45733 Φ 0.5 ruby ball  
13  
ø0.5 ruby ball  
Φ 0.5 ruby ball  
Integrated with arm  
16.5 8.5  
DM45522  
DM45523  
DM45524  
DM45525  
DM45526  
DM45527  
3
3
2
3
3
2
60  
34  
21  
60  
34  
21  
52 DM45531  
26 DM45528 Φ 0.7 ruby ball  
13 DM45529  
52 DM45531  
26 DM45528 Φ 1 ruby ball  
13 DM45529  
*Indicates stylus/arm set DM45500  
Standard Inventory Parts  
*1:Requires master ball calibration unit for small holes.  
90  
TOKYO SEIMITSU  
Contour Detectors and Arms  
Applicable models  
Measuring application  
C1710  
C2600  
C2700  
S1910  
S2800  
S2900  
Model  
External view  
Applicable arm stylus  
Remarks  
E-DT-CH07A  
C2600, S2800E/G  
Contour detector  
E-DT-CH08A  
E-DT-CH10B  
C2700DX/SD, S2900DX/SD  
C1710DX/SD, S1910DX/SD  
General purpose  
DM45502  
DM45505  
DM45508  
DM45523  
DM45526  
Standard configuration  
Deflection: Approx. 1.2 μm for 10 mN  
Approx. 3.7 μm for 30 mN  
DM45528  
DM45529  
DM45530*  
DM45531  
DM45532*  
DM45533  
DM45500  
Inner surface  
DM45503  
DM45506  
DM45509  
DM45524  
DM45527  
Deflection: Approx. 1.2 μm for 10 mN  
Approx. 3.7 μm for 30 mN  
179  
Small holes  
DM45510  
to  
DM45521  
Stylus combination arm for  
measuring small holes  
Deep grooves  
DM45501  
DM45504  
DM45507  
DM45522  
DM45525  
Measuring force: 10 mN or less  
(Provided with auxiliary weight)  
Deflection: Approx. 1.2 μm for 10 mN  
Approx. 3.7 μm for 30 mN  
Offset measurement  
DM45502  
DM45505  
DM45508  
DM45523  
DM45526  
Measuring force: 10 mN or less  
(Provided with auxiliary weight)  
Deflection: Approx. 2.6 μm for 10 mN  
Approx. 7.8 μm for 30 mN  
DM45503  
DM45506  
DM45509  
DM45524  
DM45527  
179  
Measuring force: 10 mN or less  
(Provided with auxiliary weight)  
Deflection: Approx. 2.6 μm for 10 mN  
Approx. 7.8 μm for 30 mN  
Stylus : DM45505, DM45508,  
DM45513, DM45515  
Arm/stylus set  
Arms : DM45530, DM45532  
*Indicates stylus/arm set DM45500  
Standard Inventory Parts  
91  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Adjustment Devices  
Applicable models  
S480  
S1400  
S1500  
S2000  
S5000  
C1600  
S1800  
C1700/C1710  
S1900/S1910  
S2000  
C2600  
S2800  
C2700  
S2900  
S-NEX  
Orthogonal axis adjustment  
Swivel adjust-  
Tilt adjust-  
Table size Allowable load  
(mm)  
ment  
ment  
Name  
Model  
External view  
Remarks  
(mm)  
(net wt.) (kg)  
X
Y
Z
Fine Coarse Fine Coarse  
20  
(7)  
Min. reading  
increment 10 μm  
Adjustment stand  
E-AT-S01D  
E-AT-S02A  
E-AT-S03A  
E-AT-S04A  
E-AT-S05A  
E-AT-S36A  
E-AT-S08A  
E-AT-S10B  
E-AT-S11B  
E-AT-S12A  
E-AT-S13B  
E-AT-S64B  
E-WJ-S03A  
50  
50  
8°  
360°  
Φ 150  
Leveling  
adjustment stand  
15  
(3)  
±1.5°  
80 × 110  
80 × 58  
80 × 125  
120 × 58  
200 × 120  
150 × 150  
75 × 40  
125 × 150  
Φ 90  
3
(0.9)  
±2.5  
±8  
±2°  
±3°  
±1°  
±1°  
For E-RM-S75A  
15  
(8)  
Adjustment stand  
3
(1.4)  
±3  
For E-RM-S76A  
For E-RM-S77A  
5
(4.5)  
±3  
X-direction  
movement  
adjustment stand  
20  
(25)  
400  
55  
3D fine  
adjustment stand  
1
(3.4)  
55  
50  
28  
Straightness: 0.03 mm  
Straightness: 3 μm  
Min. reading value:  
10 μm  
1-axis precision  
fine adjustment stand  
20  
(4.9)  
Swivel fine  
rotation stand  
3
±5° 360°  
• Min. reading value: 5’  
(0.58)  
10  
Straightness: 3 μm  
Min. reading value:  
0.5 μm  
1-axis ultra precision  
fine adjustment stand  
10  
(0.7)  
Coarse  
movement:  
10 μm  
60 × 60  
60 × 120  
Φ 110  
0.m5oμvemme)nt:  
Fine  
10  
(1)  
Tilting stand  
±20°  
• Min. reading value: 5’  
3
(2.5)  
X/Y-direction  
adjustment  
Universal stand  
Column rotary spacer  
Column spacer  
360°  
360°  
±90°  
*1  
E-CS-S31A  
Inserted between  
table and column  
H:100  
H:200  
*3  
E-CS-S76A  
*1  
E-CS-S32A  
Inserted between  
table and column  
*3  
E-CS-S77A  
Inserted between  
column and tracing  
driver  
Tracing driver spacer E-CS-S33A*1  
L : 70  
For contour measurements  
E-CA-S85A:  
E-CA-S24A*2  
E-CA-S85A*3  
±15°  
±5°  
For tracing driver 100 mm  
E-CA-S92A:  
E-CA-S92A*3  
Tracing driver tilting  
device  
For tracing driver 200 mm  
E-CA-S32A*2  
For roughness  
measurements  
(5)  
E-CA-S101A*3  
*1: Cannot be used with S3000A Series and S5000 Series.  
*2: Cannot be used for Linear Series and S3000A and S5000 Series. For S1400D,S1800D,S2800E,C1600D,C2600E.  
*3: For Linear Series and S1400G, C1600G, S1800G, C2600G, S2800G and S2800G Series.  
Standard Inventory Parts  
92  
TOKYO SEIMITSU  
Holders  
Applicable models  
Name  
S480  
S1400  
S1500  
S2000  
S5000  
C1600  
S1800  
C1700/C1710  
Chucking  
(mm)  
S1900/S1910  
Vice  
(mm)  
S2000  
Clamp  
(mm)  
C2600  
S2800  
C2700  
S2900  
S-NEX  
V Holder  
Flat surface Allowable load  
(mm)  
Model  
External view  
Remarks  
(mm)  
(net wt.) (kg)  
Inside: 59  
outside:  
38 to 105  
Consult us when  
combining with the  
tilt stand.  
5
(0.8)  
Double-side open vice E-WJ-S01B  
Provided with  
workpiece clamper  
V-stand set  
E-WJ-S02A  
E-WJ-S04A  
E-WJ-S05A  
E-WJ-S06A  
E-WJ-R01C  
Φ 1 to Φ 150  
Φ 12 to Φ 150  
Φ 4 to Φ 10  
(1.5)  
(3)  
Two pieces used  
just for T-groove  
clamp  
V-stand holder set  
Compact stand  
Load plate  
(0.4)  
(1)  
150 × 150  
angle  
plate  
OD:  
Φ 2 to Φ 79  
ID:  
Scroll chuck  
Iris chuck  
(1)  
Φ 56 to Φ 90  
OD:  
Φ 5 to Φ 110  
OD:  
00  
( 3 )  
00  
E-WJ-R10A  
E-WJ-R378A  
Manufactured after  
receipt of order  
Φ 5 to Φ 150  
( 5 )  
Height  
40 to 60  
Clamp set  
JC-3  
-
300 × 300  
angle  
plate  
Manufactured after  
receipt of order  
E-WJ-S252A  
E-WJ-S234A  
(5.3)  
(15)  
Ceramic load plate  
500 × 500  
angle  
plate  
Manufactured after  
receipt of order  
Standard Inventory Parts  
Sample Adjustment Stand/Holder Configurations  
Scroll chuck  
E-WJ-R01C  
V-stand set  
V-stand set  
E-WJ-S02A  
E-WJ-S02A  
Universal stand  
E-WJ-S03A  
Tracing driver  
E-RM-S76A  
Leveling  
adjustment stand  
E-AT-S02A  
Adjustment  
stand  
E-AT-S05A  
Adjustment stand  
E-AT-S04A  
Adjustment stand  
E-AT-S04A  
V-stand set  
E-WJ-S02A  
V-holder set  
E-WJ-S04A  
Adjustment  
stand  
Double-side open vice  
E-WJ-S01B  
E-AT-S01D  
Universal stand  
E-WJ-S03A  
X-direction movement  
adjustment stand  
E-AT-S08A  
X-direction movement  
adjustment stand  
E-AT-S08A  
Adjustment stand  
E-AT-S01D  
93  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Peripherals  
Name  
Model  
External view  
Specifications  
Remarks  
E-RM-S72B:  
Drive distance: 100 mm  
Driving speed: 0.03 mm/s to 6.0 mm/s, 8  
speeds  
Straightness accuracy: (0.05 + 1.5L/1000) μm  
Weight: Approx. 9 kg  
excluding C2600, 2800  
E-RM-S138B:  
E-RM-S72B/  
S138B  
for C2600, 2800  
S480: E-RM-S71B  
Specifications same  
as shown to left  
E-RM-S178B:  
Drive distance: 200 mm  
excluding C2600, 2800  
E-RM-S182B:  
Pickup  
movement  
tracing driver  
(For standard series)  
E-RM-S178A/  
S182A  
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds  
Straightness accuracy: (0.05 + 1.5L/1000) μm  
Weight: Approx. 15 kg  
for C2600, 2800  
S480: E-RM-S73B  
Specifications same  
as shown to left  
Drive distance: 100 mm  
S480: E-RM-S78A  
Specifications same  
as shown to left  
Driving speed: 0.003 mm/s to 6.0 mm/s, 11 speeds  
Straightness accuracy: (0.05 + 1.5L/1000) μm  
Weight: Approx. 9 kg  
E-RM-S141A  
E-RM-S205A  
E-RM-S183E  
Drive distance: 100 mm  
Driving speed: 0.03 mm/s to 6.0 mm/s  
Straightness accuracy: (0.05 + L/1000) μm  
Weight: Approx. 9 kg  
Pickup  
movement  
tracing driver  
(For linear series)  
Drive distance: 200 mm  
Driving speed: 0.03 mm/s to 6.0 mm/s  
Straightness accuracy: (0.05 + L/1000) μm  
Weight: Approx. 15 kg  
Drive distance: 50 mm  
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds Cannot be used for  
Straightness accuracy: (0.05 + 1.5L/1000) μm  
Weight: Approx. 15 kg  
Load weight: 5 kg  
Linear Series.  
Requires pickup  
holder stand.  
E-RM-S75A  
E-RM-S76A  
E-RM-S77B  
Leveling range: ±1.5°  
Drive distance: 150 mm  
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds Cannot be used for  
Straightness accuracy: (0.05 + 1.5L/1000) μm  
Weight: Approx. 20 kg  
Load weight: 5 kg  
Workpiece  
movement  
tracing driver  
Linear Series.  
Requires pickup  
holder stand.  
Leveling range: ±1°  
Drive distance: 300 mm  
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds Cannot be used for  
Straightness accuracy: (0.05 + 1.5L/1000) μm  
Weight: Approx. 32 kg  
Load weight: 10 kg  
Linear Series.  
Requires pickup  
holder stand.  
Leveling range: ±0.8°  
Measuring OD: Φ 12 mm to 20 mm  
Length: 30 mm to 150 mm  
OD: Φ 20 to 150 mm  
Length: 30 mm to 250 mm  
Peripheral velocity: 0.3, 0.6, 1.5 mm/s  
Weight: Approx. 7 kg  
Outer periphery  
roughness  
tracing driver  
E-RM-S85B  
Load weight: 5 kg  
Measuring radius: 0.25 mm to 40 mm  
Rotation accuracy: ±0.25 μm (180° arbitrary)  
Peripheral velocity: 0.3 mm/s (stepless)  
Weight: Approx. 15 kg  
Round surface  
roughness  
tracing driver  
E-RM-S84A  
Y-axis direction  
stroke 200  
Range of movement :  
X : 660 mm  
Y : 200 mm  
For measurement of  
large and heavy parts  
(Manufactured upon  
receipt of order)  
Column cross  
feed device  
E-ST-S131A  
Weight: Approx. 370 kg  
Leveling range: ±2°  
Load weight: 5 kg  
Auto tilting table  
E-AT-S72A  
Standard Inventory Parts  
94  
TOKYO SEIMITSU  
Name  
Model  
E-DH-  
External view  
Specifications  
Remarks  
Maximum extrusion:  
90mm from left end of driver  
Column height:  
10mm less than normal height  
For S2000DX/SD  
Wide-Range (Hybrid)  
Detector Holder  
Magnification:x5000 or less  
Straightness:0.5 μm/100 mm  
S182A  
Pickup  
holder stand  
E-CA-  
S25A  
When workpiece movement tracing  
driver is used  
Weight: Approx. 1.5 kg  
M a g n ifi c a t io n :  
Skid measurement x5000  
Min. inner dia: Up to Φ 25 mm  
Max. depth: 650 mm  
Used with large measuring stand  
For S480B, S1400G, S1800G, S2800G  
010 2736  
Weight: Approx. 1.2 kg  
Rod diameter: Φ 21.7 mm  
Connecting rod  
for ultra-long hole  
measurement  
Magnification: Up to x5000  
Min. inner dia: Up to Φ 18 mm  
Max. depth: 630 mm  
Weight: Approx. 1.2 kg  
Rod diameter: Φ 14 mm  
For S1500, S1900G, S1910, S2900,  
S-NEX001, 031, 041, 131, 141  
DM57537  
010 2744  
010 2745  
010 2746  
Used with 010 2804 and  
010 2808 contour profile arms  
Applicable to all models  
Coupling length: 30 mm  
Weight: Approx. 0.25 kg  
Pickup holder  
coupling  
Measuring depth: Up to 131 mm  
beneath tracing driver  
Weight: Approx. 0.47 kg  
Applicable to all models  
Measuring depth: 142 mm  
beneath detector holder  
Weight: Approx. 0.2 kg  
Rod diameter: Φ 21.7 mm  
Pickup right  
angle coupling/  
connecting rod  
Pickup vertical measurement using  
hole bottom stylus  
Ordinary stand  
for desktop  
anti-vibration table  
Dimensions:  
510 mm × 430 mm × 643 mm  
Weight: 22 kg  
E-VS-  
S13A  
For E-VS-S57A/B, E-VS-S58A  
510  
430  
Anti-vibration: Pneumatic diaphragm spring  
Natural frequency: 2.5 Hz to 3.5 Hz  
Load weight: 130 kg  
Dimensions: 600 mm × 530 mm × 60 mm  
Air source: 350 kPa to 700 kPa  
Weight: 25 kg  
With regulator  
Air tube (external diameter Φ 6)  
attached.  
E-VS-  
S57B  
Desktop  
anti-vibration table  
Anti-vibration: Pneumatic diaphragm spring  
Natural frequency: 2.5 Hz to 3.5 Hz  
Load weight: 130 kg  
Dimensions: 600 mm × 530 mm × 60 mm  
Weight: 25 kg  
E-VS-  
S58B  
Air source: Pump  
1000  
Anti-vibration:  
Pneumatic diaphragm spring  
Natural frequency: 4 Hz  
Load weight: 300 kg  
Dimensions:  
Desktop large  
anti-vibration table  
E-VS-  
S45A  
Air source: Pump  
1000 mm × 750 mm × 143 mm  
Weight: 80 kg  
125  
750  
125  
Anti-vibration: Pneumatic diaphragm spring  
Natural frequency: V: 2 Hz; H: 2.2 Hz  
Load weight: 250 kg  
Dimensions: 980 mm × 780 mm × 700 mm  
Air source: 350 kPa to 700 kPa  
Weight: 170 kg  
E-VS-  
R16B  
With regulator  
Anti-vibration table  
Anti-vibration: Pneumatic diaphragm spring  
Natural frequency: V: 1.6 Hz; H: 2 Hz  
Load weight: 550 kg  
Dimensions: 1100 mm × 850 mm × 700 mm  
Air source: 350 kPa to 700 kPa  
Weight: 340 kg  
E-VS-  
S21B  
With regulator  
*3 If retrofitted to S2000 and SNE100, correction value needs to be obtained again.  
Standard Inventory Parts  
95  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Name  
Model  
External view  
Specifications  
Remarks  
Dimensions:  
E-DK-S24A  
800 mm × 800 mm × (1070 to 1370) mm  
Weight: 44.5 kg  
System rack  
Dimensions:  
1200 mm × 800 mm × (1070 to 1370) mm  
E-DK-S25A  
Dimensions:  
400 mm × 700 mm × 700 mm  
Side desk  
E-DK-S10A  
Used with desktop anti-vi-  
bration table/stand for  
roughness measuring  
For Standard/Linear  
series SD type (Excluding  
S5000, S3000)  
Transparent  
vinyl sheet  
Dimensions:  
750 mm × 614 mm × 810 mm  
Weight: 8 kg  
E-CV-S02A  
W
D
Transparent  
acrylic plate  
High magnifi-  
cation  
dust cover  
H
Used with desktop anti-vi-  
bration table/stand for  
contour profile measure-  
ment  
Dimensions:  
1000 mm × 629 mm × 810 mm  
Weight: 13 kg  
E-CV-S03A  
For Standard/Linear series  
SD type  
(Excluding S5000, S3000)  
Dimensions:  
1070 mm × 750 mm × 1050 mm  
Weight: 20 kg  
Used with E-VS-S21A an-  
ti-vibration table for large  
measuring table  
Dust cover  
E-CV-S25A  
Microscope  
X25  
Magnification: x20  
Focal distance: 60 mm  
E-MA-S81A  
DM59014  
E-MA-S84A  
DM59103  
Stand type  
Stand  
Microscope knob  
Measuring  
position  
verification unit  
Light guide (option)  
Can be used with work-  
piece movement tracing  
driver  
CCD camera  
Magnification: x20  
Focal distance: 60 mm  
(option)  
Microscope  
Flexible arm  
Fine  
movement  
knob  
Light guide  
Flexible arm  
Light  
Stand type  
Fixing knob  
115  
70  
Light guide (option)  
Configuration  
(1) Color camera  
(2) Color monitor  
(3) Power adapter  
(4) Microscope adapter  
(5) Connection cable  
(6) Instruction manual  
Image sensor:  
Color camera  
monitoring  
system  
Interline type CCD  
Effective pixels:  
768 mm × 494 mm  
CCD camera  
(option)  
Microscope  
(sold separately)  
Standard Inventory Parts  
96  
TOKYO SEIMITSU  
Name  
Model  
External view  
Specifications  
Remarks  
For pickup movement tracing  
driver  
Tape tension jig DM58526  
Calibration surface:  
Approx. 3.1 μm Ra  
Stylus check surface:  
Approx. 0.4 μm Ra  
Measured value described.  
For sensitivity calibration and for  
checking stylus  
Applicable to JCSS calibration  
and NIST calibration  
Reference  
E-MC-S24C  
specimen  
Standard accessory for linear  
series roughness system  
For detector sensitivity calibration  
and stylus check  
Level  
Large range: Approx. 20 μm  
Small range: Approx. 2 μm  
Measured value described.  
difference  
E-MC-S57A  
reference  
specimen  
Applicable to JCSS calibration  
Narrow range accuracy:  
0 to 10 μm ±0.1 μm  
Wide range accuracy:  
0 to 400 μm ±1.0 μm  
Magnification  
E-MC-S50C  
calibrator  
For magnification calibration  
181.5  
Block gage  
Master ball  
ø12.7mm(1/2)  
For measurements with stylus  
pointing downwards  
46  
25  
E-MC-S34A  
Standard accessory for  
C1600D/G, C2600E/G,  
C1700DX/SD, C2700DX/SD  
Y-direction adjustment  
table  
60  
85  
Block gage
マスターボール  
Master ball  
For measurements with stylus  
pointing downwards  
Standard accessory for  
S2000DX/SD, SNEX100  
Y-direction adjustment table  
E-MC-S65B  
60  
82  
Master ball  
calibration unit  
For measurements with stylus  
pointing downwards  
Standard accessory for  
S3000A, S5000DX/SD  
E-MC-S48A  
Master ball calibration unit  
For measurements with stylus  
pointing upwards  
For C2600E/G, S3000A,  
C2700DX/SD, S5000DX/SD  
E-MC-S51A  
For measurements with stylus  
pointing downwards and stylus  
for small bore measurement  
For C1600, C1700DX/SD,  
C2600, S3000A  
For C2700DX/SD, S2000DX/SD,  
S5000DX/SD, S2000, SNEX100  
Block gageꢀ1.5mm  
Calibration ball  
5 m m  
Small hole  
stylus master  
E-MC-S59D  
ball calibration  
φ
Block gage: 1.5 mm  
Reference sphere: Φ1.5 mm  
6
unit  
Standard  
plate  
63  
Pin diameter: 7.9 mm  
Pitch: 15 mm  
Dimensions:  
Pitch gage  
E-MG-S02A  
E-MG-S24A  
144 mm × 38 mm × 49 mm  
1
(Edge line length)  
90
°
 
Stylus check  
master  
Tip radius: 0.1 μm or less  
Material: Knife edge diamond  
ø64  
Input: 90 V to 240 V  
Output: 100 V  
Capacity: 2.1 kVA  
Dimensions:  
300 mm × 350 mm × 296 mm  
Weight: 45 kg  
Power  
transformer  
box  
E-TF-R25A  
Specify the input voltage  
Standard Inventory Parts  
97  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Accessories for SURFCOM 130A, FLEX-50A  
Name  
Model  
External view  
Specifications  
Table size:  
Remarks  
410 mm × 200 mm  
Max. measuring height:  
200 mm  
Weight: Approx. 18 kg  
Load weight: 20 kg  
Compact  
measuring  
stand  
Tracing driver height and tilt can be  
adjustable depending on a size  
and form of a workpiece  
0
10  
20  
30  
40  
50  
MILLIMETER  
INCH  
S
U
R
F
C
O
M
1
3
0
A
E-ST-S130A  
128 ~178  
68  
330  
60  
20  
135  
60  
5
410  
200  
All orientations  
5 μm R90°conical diamond, Horizontal tracing possible  
E-DT-SE18A  
4mN  
With 0102501 stylus  
For S130A, S-FLEX50A  
Pickup  
2 μm R60°conical diamond,  
0.7mN  
E-DT-SE19A  
E-MA-S54A  
Standard accessory  
Touch pen  
Battery set  
Specialized for S130A, S480A/B  
Battery charger for 130A  
Size: 80 mm × 85 mm × 45 mm  
Weight: Approx. 400 g  
Charging time: 4 hours  
Measurements and recording are available  
on-site where there is no power source  
E-MA-S65A  
Contents:  
AC adapter, battery charger, battery  
Battery for 130A  
Size: 203 mm × 58 mm × 67 mm  
Weight: Approx. 1.2 g  
Attachment for placing the tracing driver  
on a roll shaped object for measurement  
Roll outer diameter: Φ 60 mm or more  
E-MA-S62A  
Roll foot  
Photo shows unit of E-MA-63A  
Roll outer diameter: Φ 60 mm or more  
E-MA-S63A  
E-MA-S64A  
For Amplification indicator  
Specialized for S130A, S480A/B  
Dust proof cover  
For measuring surface roughness of  
slanted surfaces, vertical surfaces, ceiling  
surfaces and other non-flat surfaces  
Limited to the skid measurement  
All position pickup  
holder  
E-DH-S107A  
Attachment for horizontal tracing of items,  
such as crankshafts which have obstacles  
in the front and back in the measuring  
direction  
(using double-side stradding skid)  
Limited to the skid measurement  
Horizontal tracing  
pickup holder  
E-DH-S17A  
E-CA-S62A  
Attachment for  
tracing driver  
50 mm tracing driver attached to manual  
column (E-CL-S133A)  
Cable connected  
Specialized for S130A  
RS-232C cable  
E-SC-S288A  
E-MC-S24C  
Support 9pin Windows PC  
Calibration surface:  
Approx. 3.1 μmRa  
Stylus check surface:  
Approx. 0.4 μmRa  
Reference  
specimen  
For sensitivity calibration and stylus check  
Standard accessory  
Measured value described  
Standard Inventory Parts  
98  
TOKYO SEIMITSU  
Accessories for HANDYSURF E-35B, 40A, 45A and SURFCOM FLEX-35B, 40A, 45A  
Name  
Model  
External view  
Specifications  
Remarks  
For general  
measurement  
Standard accessory  
E-DT-SM10A  
E-DT-SM49A  
E-DT-SM39A  
5 μm, 90° conical diamond, 4 mN (For 35B · 40A)  
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A)  
5 μm, 90° conical diamond, 4 mN (For 45A)  
For fine hole  
Min. inner diameter:  
Φ 5 mm  
E-DT-SM11A  
E-DT-SM50A  
5 μm, 90° conical diamond, 4 mN (For 35B · 40A)  
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A)  
Pickup  
For extra fine hole  
E-DT-SM12A  
E-DT-SM51A  
5 μm, 90° conical diamond, 4 mN (For 35B · 40A)  
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A)  
Min. inner diameter:  
Φ 3 mm  
5 μm, 90° conical diamond, 4 mN (For 35B · 40A) For deep groove  
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A) Max. depth: 7 mm  
E-DT-SM13A  
E-DT-SM52A  
クラン解除レバー  
ワーク端面  
For HANDYSURF  
E-35B and SURFCOM  
FLEX-35B  
With attachment  
mechanism  
最大測定径  
Ø95  
Ø71.5  
クランプローラ  
最小測定径  
Specialized driver for  
the bore roughness E-RM-S224C  
measurement  
Measuring range 130 mm  
Max. measuring diameter Φ95 mm  
Min. measuring diameter Φ71.5 mm  
130  
120  
110  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
130 (測定範囲  
)
100  
340  
Standard accessory  
for 35B, 40A  
E-WJ-S64A  
Adjustment device  
(Rear)  
Standard accessory  
for 45A  
E-WJ-S559A  
For 35B, 40A  
E-WJ-S80A  
Adjustment device  
(Front)  
For 45A  
E-WJ-S560A  
Place a  
For 35B  
E-WJ-S85A  
V-shaped part  
at lower side on  
a workpiece for  
measurement  
Applicable up to  
Φ 50  
Nose piece (Cyl-  
inder)  
For 35B, 40A  
For 35B  
E-WJ-S562A  
Place a  
E-WJ-S88A  
Nose piece (Flat)  
protrusion and  
lower side of  
tracing driver on  
a workpiece for  
measurement  
For 35B, 40A  
E-WJ-S561A  
Standard accessory  
for 45A  
Nose piece  
E-WJ-S536A  
(V-shape)  
Nose piece  
For 45A  
E-WJ-S563A  
(contact type)  
長穴測定用アダプタ  
(DT57507)  
ピックアップ(E-DT-SM10A)  
駆動部(E-RM-S59A)  
Extension adapter  
DM57506  
For 35B, 40A  
for long hole  
67.5~ 80  
2 or more  
adaptors  
cannot be  
used.  
駆動部(E-RM-S59A)  
ピックアップ(E-DT-SM10A)  
横トレ-スホルダ  
(DT57507)  
Adapter for hori-  
zontal measure-  
ment  
For 35B, 40A  
DM57507  
4.5  
1.5  
68  
22  
Adapter for bore  
measurement  
For 35B, 40A  
E-WJ-S86A  
Place a central pin on a lower bore  
Standard Inventory Parts  
99  
TOKYO SEIMITSU  
Surface Texture – Contour  
Measuring Instruments  
SURFCOM · CONTOURECORD Option  
Accessories for HANDYSURF E-35B, 40A, 45A and SURFCOM FLEX-35B, 40A, 45A  
Name  
Model  
External view  
Specifications  
Remarks  
Holder for tracing  
driver  
E-MD-S200A  
Mounted on side of FLEX amplifier  
For FLEX-35B, 40A  
Magnetic stand  
Post mount holder  
Post mount  
E-ST-MAC  
010 2050  
E-CS-S26A  
E-WJ-S93A  
For Φ 6  
Cross-section surface on scriber of height  
gage:  
9 mm × 9 mm  
Adapter for height  
gage  
Used with post mount,  
E-SC-S26A  
With sample program for  
communication  
E-SC-S366A  
RS-232C cable  
Support 9 pin Windows PC  
Used with E-SC-S366A in  
case PC has no RS port  
USB-RS adapter  
Consumables  
Name  
Model  
External view  
Specifications  
Remarks  
128MB  
Remarks  
Provides registrations of approx. 500  
measurement conditions and storage of  
approx. 500 measurement data  
(200 text management items)  
CF card +  
adaptor  
E-MU-S50C  
130A, 480B  
130A, 480B  
10 rolls/box  
E-CH-S21A  
E-CH-S25A  
External diameter: Φ 47 mm,  
external width: 58 mm, roll length: 25 m  
High-speed printer for E35A , E35B,  
E40A, E45A  
E-RC-S24A  
Compact printer for E35A, E35B, E40A, E45A  
built-in printer for FLEX,  
compact printer II for E35A/B, E40A,  
E45A  
E-RC-S23A  
E-RC-S25A  
E-RC-S29A  
10 rolls/box  
External diameter: Φ 24 mm,  
external width: 58 mm, roll length: 7 m  
100B, 300B, 400B, 500B, 700B, 720B  
550A, 900A/B, 920A, 730A, 470A, 740A  
E-RC-S01A/B  
E-RA-S01A  
E-RA-S03A  
10 rolls/box  
External diameter: Φ 58 mm,  
external width: 80 mm, roll length: 40 m  
Grid width□50mm  
E-CH-50A  
200B  
Recording  
paper  
200C  
570A, 590A, 750A, 790A  
440A, 470A, 740A, 900B, 920B  
10 rolls/box  
External diameter: Φ 58 mm,  
external width: 60 mm, roll length: 40 m  
E-CH-S05B  
E-RC-S09A  
20 rolls/box  
External diameter: Φ 50 mm,  
external width: 68 mm, roll length: 25 m  
110A, 350A, 550A, 470A  
730A, 740A, 920  
E-CH-S02A  
JIS No.121  
E-CH-S26A  
E-IR-S01A  
100 sheets/leaflet  
A3 leaflet  
E-RC-XY16  
E-RC-S30A  
600B/C/D  
10 rolls/box  
External diameter: Φ 38 mm,  
external width: 58 mm, roll length: 19 m  
Compact printer III for E35B, E40A,  
E45A  
110A, 110B, 350A, 550A, 470A  
730A, 740A, 920A  
Ink ribbon  
Standard Inventory Parts  
100  
TOKYO SEIMITSU  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY