AD641-EB [ADI]
250 MHz Demodulating Logarithmic Amplifier; 250 MHz的解调对数放大器型号: | AD641-EB |
厂家: | ADI |
描述: | 250 MHz Demodulating Logarithmic Amplifier |
文件: | 总16页 (文件大小:259K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
250 MHz Demodulating
Logarithmic Amplifier
a
AD641
FEATURES
PIN CONFIGURATIONS
Logarithmic Amplifier Performance
Usable to 250 MHz
44 dB Dynamic Range
20-Lead Plastic DIP (N)
20-Lead Cerdip (Q)
؎2.0 dB Log Conformance
37.5 mV/dB Voltage Output
Stable Slope and Intercepts
2.0 nV/√Hz Input Noise Voltage
50 V Input Offset Voltage
Low Power
؎5 V Supply Operation
9 mA (+VS), 35 mA (–VS) Quiescent Current
Onboard Resistors
1
2
20
19
18
17
16
15
14
13
12
11
–INPUT
ATN LO
ATN COM
ATN COM
ATN IN
+INPUT
ATN OUT
CKT COM
RG1
3
4
5
RG0
AD641
TOP VIEW
(Not to Scale)
6
BL1
RG2
7
–V
S
LOG OUT
LOG COM
8
ITC
BL2
Onboard 10
؋
Attenuator Dual Polarity Current Outputs
Direct Coupled Differential Signal Path
9
+V
S
10
–OUTPUT
+OUTPUT
APPLICATIONS
20-Lead PLCC (P)
IF/RF Signal Processing
Received Signal Strength Indicator (RSSI)
High Speed Signal Compression
High Speed Spectrum Analyzer
ECM/Radar
3
2
1
20 19
PIN 1
IDENTIFIER
ATN COM
ATN IN
BL1
4
5
6
7
8
18
17
16
15
14
CKT COM
RG1
PRODUCT DESCRIPTION
AD641
TOP VIEW
(Not to Scale)
The AD641 is a 250 MHz, demodulating logarithmic amplifier
with an accuracy of ±2.0 dB and 44 dB dynamic range. The
AD641 uses a successive detection architecture to provide an
output current that is logarithmically proportional to its input
voltage. The output current can be converted to a voltage using
one of several on-chip resistors to select the slope. A single
AD641 provides up to 44 dB of dynamic range at speeds up to
250 MHz, and two cascaded AD641s together can provide
58 dB of dynamic range at speeds up to 250 MHz. The AD641
is fully stable and well characterized over either the industrial or
military temperature ranges.
RG0
–V
S
RG2
ITC
LOG OUT
9
10 11 12 13
The 250 MHz bandwidth and temperature stability make this
product ideal for high speed signal power measurement in RF/
IF systems. ECM/Radar and Communication applications are
routinely in the 100 MHz–180 MHz range for power measure-
ment. The bandwidth and accuracy, as well as dynamic range,
make this part ideal for high speed, wide dynamic range signals.
The AD641 is not a logarithmic building block, but rather a
complete logarithmic solution for compressing and measuring
wide dynamic range signals. The AD641 is comprised of five
stages and each stage has a full wave rectifier, whose current
depends on the absolute value of its input voltage. The output
of these stages are summed together to provide the demodulated
output current scaled at 1 mA per decade (50 µA/dB).
The AD641 is offered in industrial (–40°C to +85°C) and mili-
tary (–55°C to +125°C) package temperature ranges. Industrial
versions are available in plastic DIP and PLCC; MIL versions
are packaged in cerdip.
Without utilizing the 10× input attenuator, log conformance of
2.0 dB is maintained over the input range –44 dBm to 0 dBm.
The attenuator offers the most flexibility without significantly
impacting performance.
REV. C
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
Fax: 781/326-8703
World Wide Web Site: http://www.analog.com
© Analog Devices, Inc., 1999
AD641–SPECIFICATIONS
(V = ؎5 V; T = +25؇C, unless otherwise noted)
ELECTRICAL CHARACTERISTICS
S
A
AD641A
Typ
AD641S
Typ
Parameter
Conditions
Min
Max
Min
Max
Units
TRANSFER FUNCTION1
(IOUT = IY LOG |VIN/VX|for VIN = 0.75 mV to ±200 mV dc)
LOG AMPLIFIER PERFORMANCE
3 dB Bandwidth
Voltage Compliance Range
Slope Current, IY
250
250
MHz
V
mA
–0.3
0.98
+VS – 1 –0.3
+VS – 1
1.02
1.00
1.02
0.98
1.00
Accuracy vs. Temperature
Over Temperature
Intercept dBm
0.002
0.002
%/°C
mA
dBm
dBm
mA
TMIN to TMAX
250 MHz
TMIN to TMAX, 250 MHz
0.98
1.02
–39.96
–39.47
–40.84 –40.43 –39.96
–40.84 –40.43
–40.59
Over Temperature
Zero Signal Output Current2
ITC Disabled
–0.2
–0.27
2.3
–0.2
–0.27
Pin 8 to COM
mA
mA
Maximum Output Current
2.3
DYNAMIC RANGE
Single Configuration
Over Temperature
Dual Configuration
Over Temperature
44
40
58
52
44
38
58
52
dB
dB
dB
dB
TMIN to TMAX
TMIN to TMAX
LOG CONFORMANCE
Single Configuration
Over Temperature
f = 250 MHz
–44 dBm to 0 dBm
–42 dBm to –4 dBm; TMIN to TMAX
–42 dBm to –2 dBm, TMIN to TMAX
S: –60 dBm to –2 dBm;
±0.5
±2.0
±0.5
±1.0
±2.0
±2.5
dB
dB
±1.0
±0.5
±1.0
±2.5
±2.0
±2.5
Dual Configuration
Over Temperature
±0.5
±1.0
±2.0
±2.5
dB
dB
A: –56 dBm to –4 dBm, TMIN to TMAX
LIMITER CHARACTERISTICS
Flatness
Phase Variation
–44 dBm to 0 dBm @ 10.7 MHz
–44 dBm to 0 dBm @ 10.7 MHz
±1.6
±2.0
±1.6
±2.0
dB
Degrees
INPUT CHARACTERISTICS
Input Resistance
Input Offset Voltage
vs. Temperature
Over Temperature
vs. Supply
Input Bias Current
Input Bias Offset
Differential
Differential
500
50
0.8
500
50
0.8
kΩ
µV
µV/°C
µV
µV/V
µA
200
200
300
25
TMIN to TMAX
2
7
1
2
7
1
25
µA
Common Mode Input Range
–2
+0.3
–2
+0.3
V
SIGNAL INPUT (Pins 1, 20)
Input Capacitance
Noise Spectral Density
Tangential Sensitivity
Either Pin to COM
1 kHz to 10 MHz
BW = 100 MHz
2
2
–72
2
2
–72
pF
nV/√Hz
dBm
INPUT ATTENUATOR
(Pins 2, 3, 4, 5 & 19)
Attenuation3
Pins 5 to Pin 19
Pins 5 to 3/4
20
300
20
300
dB
Ω
Input Resistance
APPLICATION RESISTORS
(Pins 15, 16, 17)
0.995 1.000 1.005
0.995 1.000
1.005
kΩ
OUTPUT CHARACTERISTICS
(Pins 10, 11)
Peak Differential Output4
Output Resistance
Quiescent Output Voltage
±180
75
–90
±180
75
–90
mV
Ω
mV
Either Pin to COM
Either Pin to COM
POWER SUPPLY
Voltage Supply Range
Quiescent Current
+VS (Pin 12)
±4.5
±7.5
±4.5
±7.5
V
TMIN to TMAX
TMIN to TMAX
9
35
15
60
9
35
15
60
mA
mA
–VS (Pin 7)
NOTES
1Logarithms to base 10 are used throughout. The response is independent of the sign of VIN
.
2The zero-signal current is a function of temperature unless internal temperature compensation (ITC) pin is grounded.
3Attenuation ratio trimmed to calibrate intercept to 10 mV when in use. It has a temperature coefficient of +0.3%/°C.
4The fully limited signal output will appear to be a square wave; its amplitude is proportional to absolute temperature.
Specifications subject to change without notice.
–2–
REV. C
AD641
ORDERING GUIDE
ABSOLUTE MAXIMUM RATINGS*
Supply Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±7.5 V
Input Voltage (Pin 1 or Pin 20 to COM) . . . –3 V to +300 mV
Attenuator Input Voltage (Pin 5 to Pin 3/4) . . . . . . . . . . . ±4 V
Storage Temperature Range, Q . . . . . . . . . . –65°C to +150°C
Storage Temperature Range, N, P . . . . . . . . –65°C to +125°C
Ambient Temperature Range, Rated Performance
Temperature
Range
Package
Description
Package
Option
Model
AD641AN
AD641AP
–40°C to +85°C Plastic DIP
–40°C to +85°C PLCC
5962-9559801MRA –55°C to +125°C Cerdip
N-20
P-20A
Q-20
Industrial, AD641A . . . . . . . . . . . . . . . . . . –40°C to +85°C
Military, AD641S . . . . . . . . . . . . . . . . . . –55°C to +125°C
Lead Temperature Range (Soldering 60 sec) . . . . . . . . +300°C
AD641-EB
Evaluation Board
THERMAL CHARACTERISTICS
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may adversely affect device reliability.
JC
JA
(؇C/W)
(؇C/W)
20-Lead Plastic DIP Package (N)
20-Lead Cerdip Package (Q)
20-Lead Plastic Leadless Chip Carrier (P) 28
24
25
61
85
75
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD641 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. C
–3–
AD641–Typical DC Performance Characteristics
1.015
1.010
1.005
1
1.20
1.15
1.10
1.05
1.00
0.95
1.006
1.004
1.002
1.000
0.998
0.996
0.994
0.995
0.990
0.985
0.980
0.90
0.85
4.5
5.0
5.5
6.0
6.5
7.0
7.5
–60 –40 –20
0
20 40 60 80 100 120 140
–60 –40 –20
0
20 40 60 80 100 120 140
POWER SUPPLY VOLTAGES – ؎ Volts
TEMPERATURE – ؇C
TEMPERATURE – ؇C
Figure 2. Intercept Voltage, VX, vs.
Temperature
Figure 3. Slope Current, IY, vs. Supply
Voltages
Figure 1. Slope Current, IY, vs.
Temperature
14
13
12
11
10
9
1.015
1.010
1.005
+0.4
+0.3
INPUT OFFSET VOLTAGE
DEVIATION WILL BE WITHIN
SHADED AREA.
+0.2
+0.1
0
1.000
0.995
0.990
0.985
–0.1
–0.2
–0.3
8
7
–60 –40 –20
0
20 40 60 80 100 120 140
–60 –40 –20
0
20 40 60 80 100 120 140
4.5
5.0
5.5
6.0
6.5
7.0
7.5
TEMPERATURE – ؇C
TEMPERATURE – ؇C
POWER SUPPLY VOLTAGES – ؎ Volts
Figure 6. Input Offset Voltage Devia-
tion vs. Temperature
Figure 5. Intercept Voltage (Using
Attenuator) vs. Temperature
Figure 4. Intercept Voltage, VX, vs.
Supply Voltages
2.5
2.0
1.5
1.0
0.5
0
2
1
0
2.5
2.0
1.5
1.0
0.5
0
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
–0.2
–0.4
0.1
1.0
10.0
100.0
1000.0
–60 –40 –20
0
20 40 60 80 100 120 140
–60 –40 –20
0
20 40 60 80 100 120 140
INPUT VOLTAGE – mV
(EITHER SIGN)
TEMPERATURE – ؇C
TEMPERATURE – ؇C
Figure 8. Absolute Error vs. Tempera-
ture, VIN = ±1 mV to ±100 mV
Figure 9. Absolute Error vs. Tempera-
ture, Using Attenuator. VIN = ±10 mV
to ±1 V, Pin 8 Grounded to Disable ITC
Bias
Figure 7. DC Logarithmic Transfer
Function and Error Curve for Single
AD641
–4–
REV. C
Typical AC Performance Characteristics–AD641
–2.00
–1.75
–1.50
–1.25
–1.00
–0.75
–0.50
–0.25
–0.00
0.25
5
–2.25
–2.00
–1.75
–1.50
–1.25
–1.00
–0.75
–0.50
50MHz
+125؇C
4
+125؇C
+25؇C
150MHz
190MHz
210MHz
250MHz
3
2
–55؇C
+25؇C
1
ERROR
–55؇C
0
+125؇C
–1
–2
–3
–4
–5
+25؇C
–55؇C
+125؇C
OUTPUT
–0.25
0.00
+25؇C
–55؇C
–52 –48 –44
0.50
0.25
–36 –32 –28 –24 –20 –16 –12 –8 –4 0 2
INPUT LEVEL – dBm
–40
–52 –48 –44
–36 –32 –28 –24 –20 –16 –12 –8 –4 0 2
INPUT LEVEL – dBm
–40
Figure 13. Logarithmic Response and Linearity at
200 MHz, TA for TA = –55°C, +25°C, +125°C
Figure 10. AC Response at 50 MHz, 150 MHz, 190 MHz,
210 MHz at 250 MHz, vs. dBm Input (Sinusoidal Input)
1.0
0.95
0.90
0.85
87.5
85.0
82.5
80.0
77.5
75.0
0.80
0.75
72.5
70.0
50
150
190
210
250
50
100
150
170
190
210
230
250
INPUT FREQUENCY – MHz
INPUT FREQUENCY – MHz
Figure 11. Intercept Level (dBm) vs. Frequency (Cascaded
AD641s—Sinusoidal Input)
Figure 14. Slope Current, IY, vs. Input Frequency
Figure 12. Baseband Pulse Response of Single AD641,
Inputs of 1 mV, 10 mV and 100 mV
Figure 15. Baseband Pulse Response of Cascaded AD641s
at Inputs of 0.2 mV, 2 mV, 20 mV and 200 mV
REV. C
–5–
AD641
LOG OUT
Q9
LOG COM
Q10
CIRCUIT DESCRIPTION
The AD641 uses five cascaded limiting amplifiers to approxi-
mate a logarithmic response to an input signal of wide dynamic
range and wide bandwidth. This type of logarithmic amplifier
has traditionally been assembled from several small scale ICs
and numerous external components. The performance of these
semidiscrete circuits is often unsatisfactory. In particular, the
logarithmic slope and intercept (see FUNDAMENTALS OF
LOGARITHMIC CONVERSION) are usually not very stable
in the presence of supply and temperature variations even after
laborious and expensive individual calibration. The AD641 em-
ploys high precision analog circuit techniques to ensure stability
of scaling over wide variations in supply voltage and tempera-
ture. Laser trimming, using ac stimuli and operating conditions
similar to those encountered in practice, provides fully cali-
brated logarithmic conversion.
COMMON
R3
75⍀
R4
75⍀
Q1
SIG
IN
SIG
OUT
Q2
R1
85⍀
R2
85⍀
Q5 Q6
Q8
Q7
Q4
Q3
–V
S
2.18mA
PTAT
1.09mA 1.09mA
PTAT PTAT
565A
565A
Figure 16. Simplified Schematic of a Single AD641 Stage
Each of the amplifier/limiter stages in the AD641 has a small
signal voltage gain of 10 dB (×3.162) and a –3 dB bandwidth of
350 MHz. Fully differential direct coupling is used throughout.
This eliminates the many interstage coupling capacitors usually
required in ac applications, and simplifies low frequency signal
processing, for example, in audio and sonar systems. The AD641
is intended for use in demodulating applications. Each stage
incorporates a detector (a full-wave transconductance rectifier)
whose output current depends on the absolute value of its input
voltage.
By summing the signals at the output of the detectors, a good
approximation to a logarithmic transfer function can be achieved.
The lower the stage gain, the more accurate the approximation,
but more stages are then needed to cover a given dynamic range.
The choice of 10 dB results in a theoretical periodic deviation or
ripple in the transfer function of ±0.15 dB from the ideal re-
sponse when the input is either a dc voltage or a square wave.
The slope of the transfer function is unaffected by the input
waveform; however, the intercept and ripple are waveform de-
pendent (see EFFECT OF WAVEFORM ON INTERCEPT).
The input will usually be an amplitude modulated sinusoidal
carrier. In these circumstances the output is a fluctuating cur-
rent at twice the carrier frequency (because of the full wave
detection) whose average value is extracted by an external low
pass filter, which recovers a logarithmic measure of the base-
band signal.
Figure 16 is a simplified schematic of one stage of the AD641.
All transistors in the basic cell operate at near zero collector to
base voltage and low bias currents, resulting in low levels of
thermally induced distortion. These arise when power shifts
from one set of transistors to another during large input signals.
Rapid recovery is essential when a small signal immediately
follows a large one. This low power operation also contributes
significantly to the excellent long term calibration stability of the
AD641.
Circuit Operation
With reference to Figure 16, the transconductance pair Q7, Q8
and load resistors R3 and R4 form a limiting amplifier having a
small signal gain of 10 dB, set by the tail current of nominally
2.18 mA at 27°C. This current is basically proportional to abso-
lute temperature (PTAT) but includes additional current to
compensate for finite beta and junction resistance. The limiting
output voltage is ±180 mV at +27°C and is PTAT. Emitter
followers Q1 and Q2 raise the input resistance of the stage,
provide level shifting to introduce collector bias for the gain
stage and detectors, reduce offset drift by forming a thermally
balanced quad with Q7 and Q8 and generate the detector bias-
ing across resistors R1 and R2.
The complete AD641, shown in Figure 17, includes two bias
regulators. One determines the small signal gain of the ampli-
fier stages; the other determines the logarithmic slope. These
bias regulators maintain a high degree of stability in the re-
sulting function by compensating for potentially large uncer-
tainties in transistor parameters, temperature and supply
voltages. A third biasing block is used to accurately control
the logarithmic intercept.
LOG COM
RG1
17
RG0
16
RG2
15
LOG OUT
14
1k⍀
1k⍀
COM
13
18
+V
S
INTERCEPT POSITIONING BIAS
12
FULL-WAVE
DETECTOR
FULL-WAVE
DETECTOR
FULL-WAVE
DETECTOR
FULL-WAVE
DETECTOR
FULL-WAVE
DETECTOR
ATN OUT 19
20
1
SIG +IN
SIG –IN
11 SIG +OUT
10dB
10dB
10dB
10dB
10dB
10
SIG –OUT
AMPLIFIER/LIMITER
AMPLIFIER/LIMITER
AMPLIFIER/LIMITER
AMPLIFIER/LIMITER
AMPLIFIER/LIMITER
2
ATN LO
27⍀
3
ATN COM
ATN COM
9
8
BL2
ITC
270⍀
30⍀
4
SLOPE BIAS REGULATOR
5
6
GAIN BIAS REGULATOR
7
–V
ATN IN
BL1
S
Figure 17. Block Diagram of the Complete AD641
–6–
REV. C
AD641
2.5
2.0
1.5
1.0
Transistors Q3 through Q6 form the full wave detector, whose
output is buffered by the cascodes Q9 and Q10. For zero input
Q3 and Q5 conduct only a small amount (a total of about 32 µA)
of the 565 µA tail currents supplied to pairs Q3–Q4 and Q5–Q6.
This “pedestal” current flows in output cascode Q9 to the LOG
OUT node (Pin 14). When driven to the peak output of the
preceding stage, Q3 or Q5 (depending on signal polarity) con-
ducts most of the tail current, and the output rises to 532 µA.
The LOG OUT current has thus changed by 500 µA as the
input has changed from zero to its maximum value. Since the
detectors are spaced at 10 dB intervals, the output increases by
50 µA/dB, or 1 mA per decade. This scaling parameter is trimmed
to absolute accuracy using a 2 kHz square wave. At frequencies
near the system bandwidth, the slope is reduced due to the
reduced output of the limiter stages, but it is still relatively in-
sensitive to temperature variations so that a simple external
slope adjustment can restore scaling accuracy.
1
0
+25؇C
–55؇C
–1
–2
+85؇C
+125؇C
0.5
0
–0.5
0.1
10
100
INPUT VOLTAGE – mV
1000
10000
Figure 19. Logarithmic Output and Absolute Error vs. DC
or Square Wave Input at TA = –55°C, +25°C, +85°C and
+125°C. Input via On-Chip Attenuator
The intercept position bias generator (Figure 17) removes the
pedestal current from the summed detector outputs. It is ad-
justed during manufacture such that the output (flowing into
Pin 14) is 1 mA when a 2 kHz square-wave input of exactly
±10 mV is applied to the AD641. This places the dc intercept at
precisely 1 mV. The LOG COM output (Pin 13) is the comple-
ment of LOG OUT. It also has a 1 mV intercept, but with an
inverted slope of –1 mA/decade. Because its pedestal is very
large (equivalent to about 100 dB), its intercept voltage is not
guaranteed. The intercept positioning currents include a special
internal temperature compensation (ITC) term which can be
disabled by connecting Pin 8 to ground.
showing the outputs at temperatures of –55°C, +25°C and
+125°C. While the slope and intercept are seen to be little af-
fected by temperature, there is a lateral shift in the end points of
the “linear” region of the transfer function, which reduces the
effective dynamic range.
The on chip attenuator can be used to handle input levels 20 dB
higher, that is, from ±7.5 mV to ±2 V for dc or square wave
inputs. It is specially designed to have a positive temperature
coefficient and is trimmed to position the intercept at 10 mV dc
(or –24 dBm for a sinusoidal input) over the full temperature
range. When using the attenuator the internal bias compensa-
tion should be disabled by grounding Pin 8. Figure 19 shows
the output at –55°C, +25°C, +85°C and +125°C for a single,
AD641 with the attenuator in use; the curves overlap almost
perfectly, and the lateral shift in the transfer function does not
occur. Therefore, the full dynamic range is available at all
temperatures.
The logarithmic function of the AD641 is absolutely calibrated
to within ±0.3 dB (or ±15 µA) for 2 kHz square-wave inputs of
±1 mV to ±100 mV, and to within ±1 dB between ±750 µV and
±200 mV. Figure 18 is a typical plot of the dc transfer function,
2.5
The output of the final limiter is available in differential form at
Pins 10 and 11. The output impedance is 75 Ω to ground from
either pin. For most input levels, this output will appear to have
roughly a square waveform. The signal path may be extended
using these outputs (see OPERATION OF CASCADED
AD641s). The logarithmic outputs from two or more AD641s
can be directly summed with full accuracy.
3
+125؇C
2
+25؇C
–55؇C
2.0
1.5
1.0
1
0
–1
–2
–55؇C
+25؇C
+125؇C
A pair of 1 kΩ applications resistors, RG1 and RG2 (Figure 17)
are accessed via Pins 15, 16 and 17. These can be used to con-
vert an output current to a voltage, with a slope of 1 V/decade
(using one resistor), 2 V/decade (both resistors in series) or
0.5 V/decade (both in parallel). Using all the resistors from two
AD641s (for example, in a cascaded configuration) ten slope
options from 0.25 V to 4 V/decade are available.
0.5
0
–0.5
0.1
1.0
10.0
INPUT VOLTAGE – mV
100.0
1000.0
Figure 18. Logarithmic Output and Absolute Error vs. DC
or Square Wave Input at TA = –55°C, +25°C, and +125°C,
Input Direct to Pins 1 and 20
REV. C
–7–
AD641
FUNDAMENTALS OF LOGARITHMIC CONVERSION
The conversion of a signal to its equivalent logarithmic value
involves a nonlinear operation, the consequences of which can be
very confusing if not fully understood. It is important to realize
from the outset that many of the familiar concepts of linear
circuits are of little relevance in this context. For example, the
incremental gain of an ideal logarithmic converter approaches
infinity as the input approaches zero. Further, an offset at the
output of a linear amplifier is simply equivalent to an offset at
the input, while in a logarithmic converter it is equivalent to a
change of amplitude at the input—a very different relationship.
IY, the Slope Current, is 1 mA. The current output can readily
be converted to a voltage with a slope of 1 V/decade, for ex-
ample, using one of the 1 kΩ resistors provided for this purpose,
in conjunction with an op amp, as shown in Figure 21.
1mA PER DECADE
R2
R1
48.7⍀
C1
330pF
AD846
OUTPUT VOLTAGE
1V PER DECADE
FOR R2 = 1k⍀
We assume a dc signal in the following discussion to simplify the
concepts; ac behavior and the effect of input waveform on cali-
bration are discussed later. A logarithmic converter having a
voltage input VIN and output VOUT must satisfy a transfer func-
tion of the form
100mV PER dB
FOR R2 = 2k⍀
12
15
14
13
11
LOG
OUT
LOG +V SIG
S
COM
+OUT
AD641
SIG
–V
ITC
8
BL2
9
S
–OUT
6
7
10
V
OUT = VY LOG (VIN/VX)
Equation (1)
Figure 21. Using an External Op Amp to Convert the
AD641 Output Current to a Buffered Voltage Output
where VY and VX are fixed voltages which determine the scaling
of the converter. The input is divided by a voltage because the
argument of a logarithm has to be a simple ratio. The logarithm
must be multiplied by a voltage to develop a voltage output.
These operations are not, of course, carried out by explicit com-
putational elements, but are inherent in the behavior of the
converter. For stable operation, VX and VY must be based on
sound design criteria and rendered stable over wide temperature
and supply voltage extremes. This aspect of RF logarithmic
amplifier design has traditionally received little attention.
Intercept Stabilization
Internally, the intercept voltage is a fraction of the thermal volt-
age kT/q, that is, VX = VXOT/TO, where VXO is the value of VX
at a reference temperature TO. So the uncorrected transfer
function has the form:
I
OUT = IY LOG (VIN TO/VXOT)
Equation (3)
Now, if the amplitude of the signal input VIN could somehow be
rendered PTAT, the intercept would be stable with tempera-
ture, since the temperature dependence in both the numerator
and denominator of the logarithmic argument would cancel.
This is what is actually achieved by interposing the on-chip
attenuator, which has the necessary temperature dependence to
cause the input to the first stage to vary in proportion to abso-
lute temperature. The end limits of the dynamic range are now
totally independent of temperature. Consequently, this is the pre-
ferred method of intercept stabilization for applications where
the input signal is sufficiently large.
When VIN = VX, the logarithm is zero. VX is, therefore, called
the Intercept Voltage, because a graph of VOUT versus LOG
(VIN)—ideally a straight line—crosses the horizontal axis at this
point (see Figure 20). For the AD641, VX is calibrated to ex-
actly 1 mV. The slope of the line is directly proportional to VY.
Base 10 logarithms are used in this context to simplify the rela-
tionship to decibel values. For VIN = 10 VX, the logarithm has a
value of 1, so the output voltage is VY. At VIN = 100 VX, the
output is 2 VY, and so on. VY can therefore be viewed either as
the Slope Voltage or as the Volts per Decade Factor.
When the attenuator is not used, the PTAT variation in VX will
result in the intercept being temperature dependent. Near 300K
(+27°C) it will vary by 20 LOG (301/300) dB/°C, about 0.03 dB/
°C. Unless corrected, the whole output function would drift up
or down by this amount with changes in temperature. In the
AD641 a temperature compensating current IYLOG(T/TO) is
added to the output. This effectively maintains a constant inter-
cept VXO. This correction is active in the default state (Pin 8
open circuited). When using the attenuator, Pin 8 should be
grounded, which disables the compensation current. The drift
term needs to be compensated only once; when the outputs of
two AD641s are summed, Pin 8 should be grounded on at least
one of the two devices (both if the attenuator is used).
The AD641 conforms to Equation (1) except that its two out-
puts are in the form of currents, rather than voltages:
IOUT = IY LOG (VIN/VX)
Equation (2)
V LOG (V /V )
Y
IN
X
IDEAL
ACTUAL
2V
Y
SLOPE = V
Y
Y
Y
Conversion Range
+
Practical logarithmic converters have an upper and lower limit
on the input, beyond which errors increase rapidly. The upper
limit occurs when the first stage in the chain is driven into limit-
ing. Above this, no further increase in the output can occur and
the transfer function flattens off. The lower limit arises because
a finite number of stages provide finite gain, and therefore at
low signal levels the system becomes a simple linear amplifier.
0
ACTUAL
INPUT ON
LOG SCALE
V
= V
X
V
= 10V
V
= 100V
IN
IN
X
IN X
–
IDEAL
Figure 20. Basic DC Transfer Function of the AD641
–8–
REV. C
AD641
2
0
Note that this lower limit is not determined by the intercept
voltage, VX; it can occur either above or below VX, depending
on the design. When using two AD641s in cascade, input offset
voltage and wideband noise are the major limitations to low
level accuracy. Offset can be eliminated in various ways. Noise
can only be reduced by lowering the system bandwidth, using a
filter between the two devices.
SQUARE
WAVE INPUT
–2
–4
–6
–8
–10
SINE WAVE
INPUT
EFFECT OF WAVEFORM ON INTERCEPT
The absolute value response of the AD641 allows inputs of
either polarity to be accepted. Thus, the logarithmic output in
response to an amplitude-symmetric square wave is a steady
value. For a sinusoidal input the fluctuating output current will
usually be low-pass filtered to extract the baseband signal. The
unfiltered output is at twice the carrier frequency, simplifying the
design of this filter when the video bandwidth must be maxi-
mized. The averaged output depends on waveform in a roughly
analogous way to waveform dependence of rms value. The effect
is to change the apparent intercept voltage. The intercept volt-
age appears to be doubled for a sinusoidal input, that is, the
averaged output in response to a sine wave of amplitude (not rms
value) of 20 mV would be the same as for a dc or square wave
input of 10 mV. Other waveforms will result in different inter-
cept factors. An amplitude-symmetric-rectangular waveform has
the same intercept as a dc input, while the average of a base-
band unipolar pulse can be determined by multiplying the
response to a dc input of the same amplitude by the duty cycle.
It is important to understand that in responding to pulsed RF
signals it is the waveform of the carrier (usually sinusoidal) not
the modulation envelope, that determines the effective intercept
voltage. Table I shows the effective intercept and resulting deci-
bel offset for commonly occurring waveforms. The input wave-
form does not affect the slope of the transfer function. Figure 22
shows the absolute deviation from the ideal response of cascaded
AD641s for three common waveforms at input levels from
–80 dBV to –10 dBV. The measured sine wave and triwave
responses are 6 dB and 8.7 dB, respectively, below the square
wave response—in agreement with theory.
TRIWAVE
INPUT
–80
–70
–60
–50
–40
–30
–20
–10
INPUT AMPLITUDE IN dB ABOVE 1V, AT 10kHz
Figure 22. Deviation from Exact Logarithmic Transfer
Function for Two Cascaded AD641s, Showing Effect of
Waveform on Calibration and Linearity
By contrast, a general time varying signal has a continuum of
values within each cycle of its waveform. The averaged output is
thereby “smoothed” because the periodic deviations away from
the ideal response, as the waveform “sweeps over” the transfer
function, tend to cancel. This smoothing effect is greatest for a
triwave input, as demonstrated in Figure 22.
The accuracy at low signal inputs is also waveform dependent.
The detectors are not perfect absolute value circuits, having a
sharp “corner” near zero; in fact they become parabolic at low
levels and behave as if there were a dead zone. Consequently,
the output tends to be higher than ideal. When there are enough
stages in the system, as when two AD641s are connected in
cascade, most detectors will be adequately loaded due to the
high overall gain, but a single AD641 does not have sufficient
gain to maintain high accuracy for low level sine wave or triwave
inputs. Figure 23 shows the absolute deviation from calibration
for the same three waveforms for a single AD641. For inputs
between –10 dBV and –40 dBV the vertical displacement of the
traces for the various waveforms remains in agreement with the
predicted dependence, but significant calibration errors arise at
low signal levels.
Table I.
Input
Waveform
Peak
or rms
Intercept
Factor
Error (Relative
to a DC Input)
4
2
SQUARE
WAVE INPUT
Square Wave
Sine Wave
Sine Wave
Triwave
Triwave
Gaussian Noise
Either
Peak
rms
Peak
rms
1
2
0.00 dB
–6.02 dB
–3.01 dB
–8.68 dB
–3.91 dB
–5.52 dB
0
1.414 (√2)
2.718 (e)
1.569 (e/√3)
1.887
–2
–4
–6
SINE WAVE
INPUT
rms
Logarithmic Conformance and Waveform
–8
–10
–12
The waveform also affects the ripple, or periodic deviation from
an ideal logarithmic response. The ripple is greatest for dc or
square wave inputs because every value of the input voltage
maps to a single location on the transfer function and thus traces
out the full nonlinearities in the logarithmic response.
TRIWAVE
INPUT
–70
–60
–50
–40
–30
–20
–10
INPUT AMPLITUDE IN dB ABOVE 1V, AT 10kHz
Figure 23. Deviation from Exact Logarithmic Transfer
Function for a Single AD641, Compare Low Level
Response with That of Figure 22
REV. C
–9–
AD641
SIGNAL MAGNITUDE
often referred to as the logarithmic offset. For dc or square wave
inputs, VX is 1 mV so the numerical value of XdBV is –60, and
Equation (4) becomes
The AD641 is a calibrated device. It is, therefore, important to
be clear in specifying the signal magnitude under all waveform
conditions. For dc or square wave inputs there is, of course, no
ambiguity. Bounded periodic signals, such as sinusoids and
triwaves, can be specified in terms of their simple amplitude
(peak value) or alternatively by their rms value (which is a mea-
sure of power when the impedance is specified). It is generally bet-
ter to define this type of signal in terms of its amplitude because
the AD641 response is a consequence of the input voltage, not
power. However, provided that the appropriate value of inter-
cept for a specific waveform is observed, rms measures may be
used. Random waveforms can only be specified in terms of rms
value because their peak value may be unbounded, as is the case
for Gaussian noise. These must be treated on a case-by-case
basis. The effective intercept given in Table I should be used for
Gaussian noise inputs.
IOUT = 50 µA (InputdBV + 60)
Equation (5)
Alternatively, for a sinusoidal input measured in dBm (power in
dB above 1 mW in a 50 Ω system) the output can be written
IOUT = 50 µA (InputdBm + 44)
Equation (6)
because the intercept for a sine wave expressed in volts rms is at
1.414 mV (from Table I) or –44 dBm.
OPERATION OF A SINGLE AD641
Figure 24 shows the basic connections for a single device, using
100 Ω load resistors. Output A is a negative going voltage with a
slope of –100 mV per decade; output B is positive going with a
slope of +100 mV per decade. For applications where absolute
calibration of the intercept is essential, the main output (from
LOG OUT, Pin 14) should be used; the LOG COM output can
then be grounded. To evaluate the demodulation response, a
simple low pass output filter having a time constant of roughly
500 µs (3 dB corner of 320 Hz) is provided by a 4.7 µF (–20%
+80%) ceramic capacitor (Erie type RPE117-Z5U-475-K50V)
placed across the load. A DVM may be used to measure the
averaged output in verification tests. The voltage compliance at
Pins 13 and 14 extends from 0.3 V below ground up to 1 V
below +VS. Since the current into Pin 14 is from –0.2 mA at
zero signal to +2.3 mA when fully limited (dc input of >300 mV)
the output never drops below –230 mV. On the other hand, the
current out of Pin 13 ranges from –0.2 mA to +2.3 mA, and if
desired, a load resistor of up to 2 kΩ can be used on this output;
the slope would then be 2 V per decade. Use of the LOG COM
output in this way provides a numerically correct decibel read-
ing on a DVM (+100 mV = +1.00 dB).
On the other hand, for bounded signals the amplitude can be
expressed either in volts or dBV (decibels relative to 1 V). For
example, a sine wave or triwave of 1 mV amplitude can also be
defined as an input of –60 dBV, one of 100 mV amplitude as
–20 dBV, and so on. RMS value is usually expressed in dBm
(decibels above 1 mW) for a specified impedance level. Through-
out this data sheet we assume a 50 Ω environment, the customary
impedance level for high speed systems, when referring to signal pow-
ers in dBm. Bearing in mind the above discussion of the effect of
waveform on the intercept calibration of the AD641, it will be
apparent that a sine wave at a power of, say, –10 dBm will not
produce the same output as a triwave or square wave of the
same power. Thus, a sine wave at a power level of –10 dBm has
an rms value of 70.7 mV or an amplitude of 100 mV (that is, √2
times as large, the ratio of amplitude to rms value for a sine
wave), while a triwave of the same power has an amplitude
which is √3 or 1.73 times its rms value, or 122.5 mV.
Board layout is very important. The AD641 has both high gain
and wide bandwidth; therefore every signal path must be very
carefully considered. A high quality ground plane is essential,
but it should not be assumed that it behaves as an equipotential
plane. Even though the application may only call for modest
bandwidth, each of the three differential signal interface pairs
(SIG IN, Pins l and 20, SIG OUT, Pins 10 and 11, and LOG,
Pins 13 and 14) must have their own “starred” ground points to
avoid oscillation at low signal levels (where the gain is highest).
“Intercept” and “Logarithmic Offset”
If the signals are expressed in dBV, we can write the output
current in a simpler form, as:
I
OUT = 50 µA (InputdBV – XdBV
)
Equation (4)
where InputdBV is the input voltage amplitude (not rms) in dBV
and XdBV is the appropriate value of the intercept (for a given wave-
form) in dBV. This form shows more clearly why the intercept is
DENOTES A SHORT, DIRECT CONNECTION
TO THE GROUND PLANE.
10⍀
+5V
ALL UNMARKED CAPACITORS ARE
0.1F CERAMIC (SEE TEXT).
OUTPUT A
OUTPUT B
NC
20
19
18
17
16
15
14
12
13
11
SIG ATN CKT RG1 RG0 RG2
+IN OUT COM
SIG
+OUT
LOG
OUT
+V
LOG
COM
R
S
R
LB
LA
1k⍀
1k⍀
100⍀
0.1%
100⍀
0.1%
4.7F
4.7F
SIGNAL
INPUT
AD641
SIG ATN ATN ATN ATN
SIG
–IN
LO COM COM IN
–OUT
BL2
9
BL1 –V
ITC
OPTIONAL
TERMINATION
RESISTOR
S
1
2
3
4
5
6
7
8
10
NC
NC
4.7⍀
OPTIONAL
OFFSET BALANCE
RESISTOR
–5V
Figure 24. Connections for a Single AD641 to Verify Basic Performance
–10–
REV. C
AD641
Unused pins (excluding Pins 8, 10 and 11) such as the attenua-
tor and applications resistors should be grounded close to the
package edge. BL1 (Pin 6) and BL2 (Pin 9) are internal bias
lines a volt or two above the –VS node; access is provided solely
for the addition of decoupling capacitors, which should be con-
nected exactly as shown (not all of them connect to the ground).
Use low impedance ceramic 0.1 µF capacitors (for example,
Erie RPE113-Z5U-105-K50V). Ferrite beads may be used
instead of supply decoupling resistors in cases where the supply
voltage is low.
Source Resistance and Input Offset
The bias currents at the signal inputs (Pins 1 and 20) are typi-
cally 7 µA. These flow in the source resistances and generate
input offset voltages which may limit the dynamic range because
the AD641 is direct coupled and an offset is indistinguishable
from a signal. It is good practice to keep the source resistances
as low as possible and to equalize the resistance seen at each
input. For example, if the source resistance to Pin 20 is 100 Ω, a
compensating resistor of 100 Ω should be placed in series with
Pin 1. The residual offset is then due to the bias current offset,
which is typically under 1 µA, causing an extra offset uncertainty
of 100 µV in this example. For a single AD641 this will rarely be
troublesome, but in some applications it may need to be nulled
out, along with the internal voltage offset component. This may
be achieved by adding an adjustable voltage of up to ±250 µV
at the unused input. (Pins 1 and 20 may be interchanged with
no change in function.)
Active Current-to-Voltage Conversion
The compliance at LOG OUT limits the available output volt-
age swing. The output of the AD641 may be converted to a
larger, buffered output voltage by the addition of an operational
amplifier connected as a current-to-voltage (transresistance)
stage, as shown in Figure 21. Using a 2 kΩ feedback resistor
(R2) the 50 µA/dB output at LOG OUT is converted to a volt-
age having a slope of +100 mV/dB, that is, 2 V per decade.
This output ranges from roughly –0.4 V for zero signal inputs
to the AD641, crosses zero at a dc input of precisely +1 mV
(or –1 mV) and is +4 V for a dc input of 100 mV. A passive
prefilter, formed by R1 and C1, minimizes the high frequency
energy conveyed to the op amp. The corner frequency is here
shown as 10 MHz. The AD846 is recommended for this appli-
cation because of its excellent performance in transresistance
modes. Its bandwidth of 35 MHz (with the 2 kΩ feedback resis-
tor) will exceed the baseband response of the system in most
applications. For lower bandwidth applications other op amps
and multipole active filters may be substituted.
In most applications there will be no need to use any offset
adjustment. However, a general offset trimming circuit is shown
in Figure 25. RS is the source resistance of the signal. Note: 50 Ω
rf sources may include a blocking capacitor and have no dc path to
ground, or may be transformer coupled and have a near zero resis-
tance to ground. Determine whether the source resistance is zero,
25 Ω or 50 Ω (with the generator terminated in 50 Ω) to find
the correct value of bias compensating resistor, RB, which
should optimally be equal to RS, unless RS = 0, in which case
use RB = 5 Ω. The value of ROS should be set to 20,000 RB to
provide a ±250 µV trim range. To null the offset, set the source
voltage to zero and use a DVM to observe the logarithmic out-
put voltage. Recall that the LOG OUT current of the AD641
exhibits an absolute value response to the input voltage, so the
offset potentiometer is adjusted to the point where the logarithmic
output “turns around” (reaches a local maximum or minimum).
Effect of Frequency on Calibration
The slope and intercept of the AD641 are calibrated during
manufacture using a 2 kHz square wave input. Calibration
depends on the gain of each stage being 10 dB. When the input
frequency is an appreciable fraction of the 350 MHz bandwidth
of the amplifier stages, their gain becomes less precise and the
logarithmic slope and intercept are no longer as calibrated.
Figure 10 shows the averaged output current versus input level
at 50 MHz, 150 MHz, 190 MHz, 210 MHz, and 250 MHz.
Figure 11 shows the absolute error in the response at 200 MHz
and at temperatures of –55°C, +25°C and +125°C. Figure 12
shows the variation in the slope current, and Figure 13 shows
the variation in the intercept level (sinusoidal input) versus
frequency.
At high frequencies it may be desirable to insert a coupling
capacitor and use a choke between Pin 20 and ground, when
Pin 1 should be taken directly to ground. Alternatively, trans-
former coupling may be used. In these cases, there is no added
offset due to bias currents. When using two dc-coupled AD641s
(overall gain 100,000), it is impractical to maintain a sufficiently
low offset voltage using a manual nulling scheme. The section
CASCADED OPERATION explains how the offset can be
automatically nulled to submicrovolt levels by the use of a nega-
tive feedback network.
If absolute calibration is essential, or some other value of slope
or intercept is required, there will usually be some point in the
user’s system at which an adjustment may be easily introduced.
For example, the 5% slope deficit at 50 MHz (see Figure 12)
may be restored by a 5% increase in the value of the load resis-
tor in the passive loading scheme shown in Figure 24, or by
inserting a trim potentiometer of 100 Ω in series with the feed-
back resistor in the scheme shown in Figure 21. The intercept
can be adjusted by adding or subtracting a small current to the
output. Since the slope current is 1 mA/decade, a 50 µA incre-
ment will move the intercept by 1 dB. Note that any error in
this current will invalidate the calibration of the AD641. For
example, if one of the 5 V supplies were used with a resistor to
generate the current to reposition the intercept by 20 dB, a
±10% variation in this supply will cause a ±2 dB error in the
absolute calibration. Of course, slope calibration is unaffected.
R
S
(SOURCE
RESISTANCE
OF
TERMINATED
GENERATOR)
20
19
AD641
1
2
R
B
+5V
20k⍀
–5V
R
OS
Figure 25. Optional Input Offset Voltage Nulling Circuit;
See Text for Component Values
REV. C
–11–
AD641
Using Higher Supply Voltages
resistor of nominally 270 Ω and low temperature coefficient
(TC). It is trimmed to calibrate the intercept to 10 mV dc (or
–24 dBm for sinusoidal inputs), that is, to an attenuation of
nominally 20 dBs at +27°C. R2 has a nominal value of 30 Ω and
has a high positive TC, such that the overall attenuation factor
is 0.33%/°C at +27°C. This results in a transmission factor that is
proportional to absolute temperature, or PTAT. (See Intercept
Stabilization for further explanation.) To improve the accuracy
of the attenuator, the ATN COM nodes are bonded to both Pin
3 and Pin 4. These should be connected directly to the “SlGNAL
LOW” of the source (for example, to the grounded side of the
signal connector, as shown in Figure 32) not to an arbitrary
point on the ground plane.
The AD641 is calibrated using ±5 V supplies. Scaling is very
insensitive to the supply voltages and higher supply voltages will
not directly cause significant errors. However, the AD641 power
dissipation must be kept below 500 mW in the interest of reli-
ability and long term stability. When using well regulated supply
voltages above ±6 V, the decoupling resistors shown in the
application schematics can be increased to maintain ±5 V at the
IC. The resistor values are calculated using the specified maxi-
mum of 15 mA current into the +VS terminal (Pin 12) and a
maximum of 60 mA into the –VS terminal (Pin 7). For example,
when using ±9 V supplies, a resistor of (9 V – 5 V)/15 mA, about
261 Ω, should be included in the +VS lead to each AD641 and
(9 V – 5 V)/60 mA, about 64.9 Ω in each –VS lead. Of course,
asymmetric supplies may be dealt with in a similar way.
R4 is identical to R2, and in shunt with R3 (270 Ω thin film)
forms a 27 Ω resistor with the same TC as the output resistance
of the attenuator. By connecting Pin 1 to ATN LOW (Pin 2)
this resistance minimizes the offset caused by bias currents. The
offset nulling scheme shown in Figure 25 may still be used, with
the external resistor RB omitted and ROS = 500 kΩ. Offset stabil-
ity is improved because the compensating voltage introduced at
Pin 20 is now PTAT. Drifts of under 1 µV/°C (referred to Pins
1 and 20) can be maintained using the attenuator.
Using the Attenuator
In applications where the signal amplitude is sufficient, the on-
chip attenuator should be used because it provides a tempera-
ture independent dynamic range (compare Figures 18 and 19).
Figure 26 shows this attenuator in more detail. R1 is a thin-film
SIG
+IN
ATN
OUT
It may occasionally be desirable to attenuate the signal even
further. For example, the source may have a full-scale value of
±10 V, and since the basic range of the AD641 extends only to
±200 mV dc, an attenuation factor of ×50 might be chosen.
This may be achieved either by using an independent external
attenuator or more simply by adding a resistor in series with
ATN IN (Pin 5). In the latter case the resistor must be trimmed
to calibrate the intercept, since the input resistance at Pin 5 is
not guaranteed. A fixed resistor of 1 kΩ in series with a 500 Ω
variable resistor calibrate to an intercept of 50 mV (or –26 dBV)
for dc or square wave inputs and provide a ±10 V input range.
The intercept stability will be degraded to about 0.003 dB/°C.
20
19
18
17
16
R1
R2
FIRST
AMPLIFIER
R3
R4
1
2
3
4
5
ATN
IN
SIG
–IN
ATN ATN
LO
ATN
COM COM
INPUT
Figure 26. Details of the Input Attenuator
DENOTES A CONNECTION TO THE
GROUND PLANE; OBSERVE COMMON
CONNECTIONS WHERE SHOWN.
ALL UNMARKED CAPACITORS ARE
0.1F CERAMIC. FOR VALUES OF
+5V
1mA/DECADE
OUTPUT
–50mV/DECADE
10⍀
10⍀
10⍀
10⍀
NUMBERED COMPONENTS SEE TEXT
SIGNAL
INPUT
C1
C2
R
= 50⍀
NC
11
C3
L
20
19
18
17
16
15
12
14
13
11
20
19
18
17
16
15
12
14
13
SIG ATN CKT RG1 RG0 RG2
+IN OUT COM
SIG
+OUT
LOG
OUT
LOG +V
COM
SIG ATN CKT RG1 RG0 RG2
+IN OUT COM
SIG
+OUT
LOG
OUT
LOG +V
COM
S
S
1k⍀
1k⍀
1k⍀
1k⍀
U2 AD641
U1 AD641
R1
SIG ATN ATN ATN ATN
SIG
SIG ATN ATN ATN ATN
SIG
–IN
LO COM COM IN
–OUT
BL2
9
–IN
LO COM COM IN
–OUT
BL2
9
BL1 –V
ITC
BL1 –V
ITC
8
S
S
1
2
3
4
5
6
7
8
10
1
2
3
4
5
6
7
10
NC
NC
R2
4.7⍀
4.7⍀
–5V
Figure 27. Basic Connections for Cascaded AD641s
–12–
REV. C
AD641
OPERATION OF CASCADED AD641S
Alternatively, the input offset can be nulled by a negative feed-
back network from the SIG OUT nodes of U2 to the SIG IN
nodes of U1, as shown in Figure 29. The low pass response of
the feedback path transforms to a closed-loop high pass response.
The high gain (×100,000) of the signal path results in a com-
mensurate reduction in the effective time constant of this net-
work. For example, to achieve a high pass corner of 100 kHz,
the low pass corner must be at 1 Hz.
Frequently, the dynamic range of the input will be 50 dB or
more. Two AD641s can be cascaded, as shown in Figure 27.
The balanced signal output from U1 becomes the input to U2.
Resistors are included in series with each LOG OUT pin and
capacitors C1 and C2 are placed directly between Pins 13 and 14
to provide a local path for the RF current at these output pairs.
C1 through C3 are chosen to provide the required low pass
corner in conjunction with the load RL. Board layout and
grounding disciplines are critically important at the high gain
(X100,000) and bandwidth (~ 150 MHz) of this system.
In fact, it is somewhat more complicated than this. When the ac
input sufficiently exceeds that of the offset, the feedback be-
comes ineffective and the response becomes essentially dc
coupled. Even for quite modest inputs the last stage will be
limiting and the output (Pins 10 and 11) of U2 will be a square
wave of about ±180 mV amplitude, dwelling approximately
equal times at its two limit values, and thus having a net average
value near zero. Only when the input is very small does the high
pass behavior of this nulling loop become apparent. Consequently,
the low pass time constant can usually be reduced considerably
without serious performance degradation.
The intercept voltage is calculated as follows. First, note that if
its LOG OUT is disconnected, U1 simply inserts 50 dB of gain
ahead of U2. This would lower the intercept by 50 dB, to
–110 dBV for square wave calibration. With the LOG OUT of
U1 added in, there is a finite zero signal current which slightly
shifts the intercept. With the intercept temperature compensa-
tion on U1 disabled this zero signal output is –270 µA equiva-
lent to a 5.4 dB upward shift in the intercept, since the slope is
50 µA/dB. Thus, the intercept is at –104.6 dBV (–88 dBm for
50 Ω sine calibration). ITC may be disabled by grounding Pin 8
of either U1 or U2.
The resistor values are chosen such that the dc feedback is
adequate to null the worst case input offset, say, 500 µV. There
must be some resistance at Pins 1 and 20 across which the offset
compensation voltage is developed. The values shown in the
figure assume that we wish to terminate a 50 Ω source at Pin 20.
The 50 Ω resistor at Pin 1 is essential, both to minimize offsets
due to bias current mismatch and because the outputs at Pins
10 and 11 can only swing negatively (from ground to –180 mV)
whereas we need to cater for input offsets of either polarity.
Cascaded AD641s can be used in dc applications, but input
offset voltage will limit the dynamic range. The dc intercept is
6 µV. The offset should not be confused with the intercept, which is
found by extrapolating the transfer function from its central “log
linear” region. This can be understood by referring to Equation
(1) and noting that an input offset is simply additive to the value
of VIN in the numerator of the logarithmic argument; it does not
affect the denominator (or intercept) VX. In dc coupled applica-
tions of wide dynamic range, special precautions must be taken
to null the input offset and minimize drift due to input bias
offset. It is recommended that the input attenuator be used,
providing a practical input range of –74 dBV (±200 µV dc) to
+6 dBV (±2 V dc) when nulled using the adjustment circuit
shown in Figure 25.
For a sine input of 1 µV amplitude (–120 dBV) and in the ab-
sence of offset, the differential voltage at Pins 10 and 11 of U2
would be almost sinusoidal but 100,000 times larger, or 100 mV.
The last limiter in U2 would be entering saturation. A 1 µV
input offset added to this signal would put the last limiter well
into saturation, and its output would then have a different aver-
age value, which is extracted by the low pass network and deliv-
ered back to the input. For larger signals, the output approaches a
square wave for zero input offset and becomes rectangular when
offset is present. The duty cycle modulation of this output now
produces the nonzero average value. Assume a maximum re-
quired differential output of 100 mV (after averaging in C1 and
C2) as shown in Figure 29. R3 through R6 can now be chosen
to provide ±500 µV of correction range, and with these values
the input offset is reduced by a factor of 500. Using 4.7 µF
capacitors, the time constant of the network is about 1.2 ms,
and its corner frequency is at 13.5 Hz. The closed loop high
pass corner (for small signals) is, therefore, at 1.35 MHz.
12
11
20 19
U1
U2
9
10
1
2
(a)
(b)
20 19
12
9
11
U1
U2
10
1
2
14A
R3
A
= –140mV
U2
INPUT
VE
–200V
4.99k⍀
R4
C1
C2
R1
50⍀
20
20
11
11
10
4.99k⍀
Figure 28. Two Methods for AC Coupling AD641s
U1
Eliminating the Effect of First Stage Offset
R2
50⍀
Usually, the input signal will be sinusoidal and U1 and U2 can
be ac coupled. Figure 28a shows a low resistance choke at the
input of U2 which shorts the dc output of U1 while preserving
the hf response. Coupling capacitors may be inserted (Figure
28b) in which case two chokes are used to provide bias paths for
U2. These chokes must exhibit high impedance over the operat-
ing frequency range.
R6
4.99k⍀
1
10
1
R5
4.99k⍀
–700V
A
= –140mV
VE
4A
Figure 29. Feedback Offset Correction Network
REV. C
–13–
AD641
PRACTICAL APPLICATIONS
RSSI APPLICATIONS
We show here two applications, using AD641s to achieve a wide
dynamic range. As already mentioned, the use of a differential
signal path and differential logarithmic outputs diminishes the
risk of instability due to poor grounding. Nevertheless, it must
be remembered that at high frequencies even very small lengths
of wire, including the leads to capacitors, have significant im-
pedance. The ground plane itself can also generate small but
troublesome voltages due to circulating currents in a poor lay-
out. A printed circuit evaluation board is available from Analog
Devices (Part Number AD641-EB) to facilitate the prototyping
of an application using one or two AD641s, plus various exter-
nal components.
The AD641 can be used to perform an RSSI (Received Signal
Strength Indicator) function. This is a commonly used function
in radio receivers, but can be used in other instrumentation such
as photomultiplier tubes. The signal strength indicator on FM
radios is one example of an RSSI application. It is this signal
that is monitored to determine where to stop during seek or
scan operations.
The AD641 is used to measure the strength of the incoming RF
signal and outputs a current that is proportional to the loga-
rithm of its ac amplitude. In this manner signal amplitudes with
a wide dynamic range and wide bandwidth can be measured.
250 MHz RSSI Converter with 44 dB Dynamic Range
At very low signal levels various effects can cause significant
deviation from the ideal response, apart from the inherent non-
linearities of the transfer function already discussed. Note that
any spurious signal presented to the AD641s is demodulated and
added to the output. Thus, in the absence of thorough shielding,
emissions from any radio transmitters or RFI from equipment
operating in the locality will cause the output to appear too
high. The only cure for this type of error is the use of very care-
ful grounding and shielding techniques.
Figure 30 shows the schematic for an RSSI circuit that uses a
single AD641. The dynamic range for this circuit using a single
AD641 is 44 dB. The AD641 amplifies and full wave rectifies
(detects) the input and outputs a current. The AD846 is used to
convert the current to a ground referenced voltage. With a 1 kΩ
feedback resistor, the output varies by 1 V/decade or 50 mV/dB.
1.0k⍀
4.7⍀
+6V
R3
100⍀
7
2
3
+6V
RSSI
OUTPUT
+50mV/dB
U3
AD846
6
68⍀
C1
47pF
4
SIGNAL
INPUT
4.7⍀
–6V
20
19
18
17
16
15
12
14
13
11
(LO)
SIG
+OUT
SIG ATN CKT RG1 RG0 RG2
+IN OUT COM
LOG
OUT
LOG +V
COM
S
1k⍀
1k⍀
U1 AD641
R1
SIG ATN ATN
ATN ATN
SIG
DENOTES A CONNECTION TO THE
GROUND PLANE; OBSERVE COMMON
CONNECTIONS WHERE SHOWN.
ALL UNMARKED CAPACITORS ARE
0.1F CERAMIC. FOR VALUES OF
NUMBERED COMPONENTS SEE TEXT
–IN
LO COM
COM IN
BL1
6
BL2
9
–OUT
–V
S
ITC
8
1
2
3
4
5
7
10
R2
NC
18⍀
–6V
Figure 30. RSSI Using Single AD641
–14–
REV. C
AD641
4.5
4
3
2.5
2
0dBm
3.5
3
0dBm
–20dBm
1.5
1
2.5
2
–20dBm
–50dBm
1.5
1
–35dBm
–50dBm
0.5
0
–80dBm
0.5
0
–0.5
1
10
100
1000
1
10
100
1000
FREQUENCY – MHz
FREQUENCY – MHz
Figure 33. Cascaded AD641s RSSI vs. Frequency
Figure 31. Single AD641 RSSI vs. Frequency
Filtering between the devices and input offset nulling techniques
described elsewhere are also useful for extending the dynamic
range of two cascaded devices.
Figure 31 shows a plot of RSSI vs. frequency for various input
signal amplitudes. It can be seen that at higher frequencies the
output drops off as explained in the section “Effect of Fre-
quency on Calibration.’’ If the RSSI circuit is to be operated at
a known frequency with limited bandwidth, the compensation
techniques described in that section can be used to enhance
accuracy.
Figure 33 shows a plot of this circuit vs. frequency for various
input amplitudes. The drop off at high frequency can be seen to
be greater than for the single device case due to the compound-
ing effects of the bandwidth limiting of the extra stages.
250 MHz RSSI Converter with 58 dB Dynamic Range
For a larger dynamic range two AD641s can be cascaded, as
shown in Figure 32. The low end usefulness of the circuit will
be set by the noise floor of the overall environment that the circuit
sees. This includes all sources of both radiated and conducted
noise. Proper layout to avoid conducted noise and good shield-
ing to minimize radiated noise are essential for good low signal
operation.
R 5
1.13k⍀
(SEE TEXT)
4.7⍀
+6V
7
2
3
LOG
OUTPUT
+50mV/dB
U3
AD846
6
4.7⍀
DENOTES A CONNECTION TO THE
GROUND PLANE; OBSERVE COMMON
CONNECTIONS WHERE SHOWN.
ALL UNMARKED CAPACITORS ARE
0.1F CERAMIC. FOR VALUES OF
NUMBERED COMPONENTS SEE TEXT
4
–6V
(LO)
+6V
R 4
100⍀
R 3
100⍀
68⍀
68⍀
C1
47pF
C 2
47pF
SIGNAL
INPUT
NC
20
19
18
17
16
15
12
14
13
11
20
19
18
17
16
15
12
14
13
11
SIG
+IN
ATN CKT RG1 RG0 RG2
OUT COM
LOG
COM
SIG ATN CKT RG1 RG0 RG2
+IN OUT COM
SIG
+OUT
LOG
OUT
+V
SIG
+OUT
LOG
OUT
LOG +V
COM
S
S
1k⍀
1k⍀
1k⍀
1k⍀
L1
(SEE
U2 AD641
U1 AD641
R1
TEXT)
SIG ATN ATN ATN ATN
SIG
SIG ATN ATN ATN ATN
SIG
–V
S
BL1
6
–IN
LO COM COM IN
ITC
BL2 –OUT
–V
S
BL2
9
–IN
LO COM COM IN
BL1
6
ITC
8
–OUT
1
2
3
4
5
9
7
8
10
1
2
3
4
5
7
10
NC
R2
NC
18⍀
18⍀
–6V
Figure 32. Complete 58 dB Dynamic Range Converter for 250 MHz Operation
REV. C
–15–
AD641
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
20-Lead Plastic DIP
(N-20)
20-Lead Cerdip
(Q-20)
0.098 (2.49) MAX
0.005 (0.13) MIN
1.060 (26.90)
0.925 (23.50)
20
11
0.310 (7.87)
0.220 (5.59)
20
11
10
PIN 1
0.280 (7.11)
0.240 (6.10)
0.320 (8.13)
0.290 (7.37)
1
10
1
0.325 (8.25)
0.300 (7.62)
0.060 (1.52)
0.015 (0.38)
PIN 1
1.060 (25.92) MAX
0.060 (1.52)
0.015 (0.38)
0.200 (5.08)
0.195 (4.95)
0.115 (2.93)
MAX
0.210 (5.33)
MAX
0.160 (4.06)
0.115 (2.93)
0.150
(3.81)
MIN
0.200 (5.08)
0.125 (3.18)
0.130
(3.30)
MIN
0.015 (0.38)
0.008 (0.20)
SEATING
0.023 (0.58) 0.100 0.070 (1.78)
PLANE
(2.54)
0.030 (0.76)
15°
0°
0.015 (0.381)
0.008 (0.204)
SEATING
PLANE
0.100
(2.54)
BSC
0.022 (0.558)
0.014 (0.356)
0.070 (1.77)
0.045 (1.15)
0.014 (0.36)
BSC
20-Lead PLCC
(P-20A)
0.180 (4.57)
0.165 (4.19)
0.048 (1.21)
0.042 (1.07)
0.056 (1.42)
0.042 (1.07)
0.025 (0.63)
0.015 (0.38)
0.048 (1.21)
0.042 (1.07)
3
19
0.021 (0.53)
0.013 (0.33)
PIN 1
IDENTIFIER
18
4
8
0.050
(1.27)
BSC
0.330 (8.38)
0.290 (7.37)
TOP VIEW
(PINS DOWN)
0.032 (0.81)
0.026 (0.66)
14
9
13
0.020
(0.50)
R
0.040 (1.01)
0.025 (0.64)
0.356 (9.04)
0.350 (8.89)
SQ
0.110 (2.79)
0.085 (2.16)
0.395 (10.02)
0.385 (9.78)
SQ
–16–
REV. C