32-Bit, 10 kSPS, Sigma-Delta ADC with 100 µs  
Settling and True Rail-to-Rail Buffers  
Data Sheet  
AD7177-2  
FEATURES  
GENERAL DESCRIPTION  
32-bit data output  
Fast and flexible output rate: 5 SPS to 10 kSPS  
Channel scan data rate of 10 kSPS/channel (100 µs settling)  
Performance specifications  
19.1 noise free bits at 10 kSPS  
The AD7177-2 is a 32-bit low noise, fast settling, multiplexed,  
2-/4-channel (fully/pseudo differential) Σ-Δ analog-to-digital  
converter (ADC) for low bandwidth inputs. It has a maximum  
channel scan rate of 10 kSPS (100 µs) for fully settled data. The  
output data rates range from 5 SPS to 10 kSPS.  
20.2 noise free bits at 2.5 kSPS  
The AD7177-2 integrates key analog and digital signal condition-  
ing blocks to allow users to configure an individual setup for  
each analog input channel in use. Each feature can be user selected  
on a per channel basis. Integrated true rail-to-rail buffers on the  
analog inputs and external reference inputs provide easy to drive  
high impedance inputs. The precision 2.5 V low drift (2 ppm/°C)  
band gap internal reference (with output reference buffer) adds  
embedded functionality to reduce external component count.  
24.6 noise free bits at 5 SPS  
INL: 1 ppm of FSR  
85 dB filter rejection of 50 Hz and 60 Hz with 50 ms settling  
User configurable input channels  
2 fully differential channels or 4 single-ended channels  
Crosspoint multiplexer  
On-chip 2.5 V reference ( 2 ppm/°C drift)  
True rail-to-rail analog and reference input buffers  
Internal or external clock  
Power supply: AVDD1 − AVSS = 5 V, AVDD2 = IOVDD = 2.5 V  
to 5 V  
Split supply with AVDD1/AVSS at 2.5 V  
ADC current: 8.4 mA  
The digital filter allows simultaneous 50 Hz and 60 Hz rejection  
at a 27.27 SPS output data rate. The user can switch between  
different filter options according to the demands of each  
channel in the application. The ADC automatically switches  
through each selected channel. Further digital processing  
functions include offset and gain calibration registers,  
configurable on a per channel basis.  
Temperature range: −40°C to +105°C  
3- or 4-wire serial digital interface (Schmitt trigger on SCLK)  
Serial port interface (SPI), QSPI, MICROWIRE, and DSP  
compatible  
The device operates with a 5 V AVDD1 supply, or with 2.5 V  
AVDD1/AVSS, and 2 V to 5 V AVDD2 and IOVDD supplies.  
The specified operating temperature range is −40°C to +105°C.  
The AD7177-2 is available in a 24-lead TSSOP package.  
APPLICATIONS  
Process control: PLC/DCS modules  
Temperature and pressure measurement  
Medical and scientific multichannel instrumentation  
Chromatography  
FUNCTIONAL BLOCK DIAGRAM  
AVDD1 AVDD2 REGCAPA  
REF– REF+ REFOUT  
IOVDD REGCAPD  
RAIL-TO-RAIL  
BUFFERED  
PRECISION  
REFERENCE  
1.8V  
LDO  
1.8V  
LDO  
REFERENCE  
CROSSPOINT  
MULTIPLEXER  
INPUT BUFFERS  
INT  
REF  
AIN0  
AIN1  
AIN2  
AIN3  
AIN4  
AVDD  
RAIL-TO-RAIL  
ANALOG INPUT  
BUFFERS  
CS  
SCLK  
SERIAL  
DIGITAL  
FILTER  
INTERFACE  
AND CONTROL  
Σ-Δ ADC  
DIN  
DOUT/RDY  
SYNC/ERROR  
GPIO AND  
MUX  
I/O CONTROL  
XTAL AND INTERNAL  
CLOCK OSCILLATOR  
CIRCUITRY  
AVSS  
AD7177-2  
TEMPERATURE  
SENSOR  
AVSS  
GPIO0 GPIO1  
XTAL1 XTAL2/CLKIO  
DGND  
Figure 1.  
Rev. B  
Document Feedback  
Information furnished by Analog Devices is believed to be accurate and reliable. However, no  
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other  
rightsof third parties that may result fromits use. Specifications subject to change without notice. No  
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.  
Trademarks andregisteredtrademarks are the property of their respective owners.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700 ©2015–2016 Analog Devices, Inc. All rights reserved.  
Technical Support  
www.analog.com  
 
 
 
 
AD7177-2* PRODUCT PAGE QUICK LINKS  
Last Content Update: 06/27/2017  
COMPARABLE PARTS  
View a parametric search of comparable parts.  
REFERENCE MATERIALS  
Technical Articles  
Fundamental Principles Behind the Sigma-Delta ADC  
Topology: Part 1  
EVALUATION KITS  
Fundamental Principles Behind the Sigma-Delta ADC  
Topology: Part 2  
AD7177-2 Evaluation Board  
Tutorials  
DOCUMENTATION  
MT-022: ADC Architectures III: Sigma-Delta ADC Basics  
Data Sheet  
MT-023: ADC Architectures IV: Sigma-Delta ADC  
Advanced Concepts and Applications  
• AD7177-2: 32-Bit, 10 kSPS, Sigma-Delta ADC with 100 μs  
Settling and True Rail-to-Rail Buffers Data Sheet  
Technical Books  
DESIGN RESOURCES  
AD7177-2 Material Declaration  
PCN-PDN Information  
The Data Conversion Handbook, 2005  
User Guides  
UG-849: Evaluating the AD7177-2 32-Bit, 10 kSPS, Sigma-  
Delta ADC with 100 µs Settling and Integrated Analog  
Input Buffers  
Quality And Reliability  
Symbols and Footprints  
SOFTWARE AND SYSTEMS REQUIREMENTS  
AD717x Microcontroller No-OS  
DISCUSSIONS  
View all AD7177-2 EngineerZone Discussions.  
AD717x Eval+ Software  
SAMPLE AND BUY  
TOOLS AND SIMULATIONS  
AD7177-2 Digital Filter Frequency Response Model  
AD7177-2 IBIS Model  
Visit the product page to see pricing options.  
TECHNICAL SUPPORT  
Submit a technical question or find your regional support  
number.  
REFERENCE DESIGNS  
CN0292  
DOCUMENT FEEDBACK  
Submit feedback for this data sheet.  
CN0364  
This page is dynamically generated by Analog Devices, Inc., and inserted into this data sheet. A dynamic change to the content on this page will not  
trigger a change to either the revision number or the content of the product data sheet. This dynamic page may be frequently modified.  
AD7177-2  
Data Sheet  
TABLE OF CONTENTS  
Features .............................................................................................. 1  
CRC Calculation......................................................................... 42  
Integrated Functions ...................................................................... 44  
General-Purpose I/O ................................................................. 44  
External Multiplexer Control ................................................... 44  
Delay ............................................................................................ 44  
24-Bit/32-Bit Conversions......................................................... 44  
DOUT_RESET ........................................................................... 44  
Synchronization.......................................................................... 44  
Error Flags................................................................................... 45  
DATA_STAT ............................................................................... 45  
IOSTRENGTH ........................................................................... 46  
Internal Temperature Sensor .................................................... 46  
Grounding and Layout .................................................................. 47  
Register Summary .......................................................................... 48  
Register Details ............................................................................... 49  
Communications Register......................................................... 49  
Status Register............................................................................. 50  
ADC Mode Register................................................................... 51  
Interface Mode Register ............................................................ 52  
Register Check............................................................................ 53  
Data Register............................................................................... 53  
GPIO Configuration Register................................................... 54  
ID Register................................................................................... 55  
Channel Register 0 ..................................................................... 55  
Channel Register 1 to Channel Register 3 .............................. 56  
Setup Configuration Register 0 ................................................ 57  
Applications....................................................................................... 1  
General Description......................................................................... 1  
Functional Block Diagram .............................................................. 1  
Revision History ............................................................................... 3  
Specifications..................................................................................... 4  
Timing Characteristics ................................................................ 7  
Absolute Maximum Ratings............................................................ 9  
Thermal Resistance ...................................................................... 9  
ESD Caution.................................................................................. 9  
Pin Configuration and Function Descriptions........................... 10  
Typical Performance Characteristics ........................................... 12  
Noise Performance and Resolution.............................................. 18  
Getting Started................................................................................ 19  
Power Supplies ............................................................................ 20  
Digital Communication............................................................. 20  
AD7177-2 Reset.......................................................................... 21  
Configuration Overview ........................................................... 21  
Circuit Description......................................................................... 27  
Buffered Analog Input ............................................................... 27  
Crosspoint Multiplexer.............................................................. 27  
AD7177-2 Reference.................................................................. 28  
Buffered Reference Input........................................................... 29  
Clock Source ............................................................................... 29  
Digital Filters................................................................................... 30  
Sinc5 + Sinc1 Filter..................................................................... 30  
Sinc3 Filter................................................................................... 30  
Single Cycle Settling................................................................... 31  
Enhanced 50 Hz and 60 Hz Rejection Filters ......................... 34  
Operating Modes............................................................................ 37  
Continuous Conversion Mode ................................................. 37  
Continuous Read Mode............................................................. 38  
Single Conversion Mode ........................................................... 39  
Standby and Power-Down Modes............................................ 40  
Calibration................................................................................... 40  
Digital Interface .............................................................................. 41  
Checksum Protection................................................................. 41  
Setup Configuration Register 1 to Setup Configuration  
Register 3 ..................................................................................... 57  
Filter Configuration Register 0................................................. 58  
Filter Configuration Register 1 to Filter Configuration  
Register 3 ..................................................................................... 59  
Offset Register 0 ......................................................................... 59  
Offset Register 1 to Offset Register 3....................................... 59  
Gain Register 0............................................................................ 59  
Gain Register 1 to Gain Register 3........................................... 59  
Outline Dimensions....................................................................... 60  
Ordering Guide .......................................................................... 60  
Rev. B | Page 2 of 60  
Data Sheet  
AD7177-2  
REVISION HISTORY  
3/16—Rev. A to Rev. B  
Changes to Power Supplies Section ..............................................20  
9/15—Rev. 0 to Rev. A  
Changes to Figure 12 and Figure 13 .............................................13  
Changes to Table 37 ........................................................................57  
Change to Table 40 and Table 42...................................................58  
3/15—Revision 0: Initial Version  
Rev. B | Page 3 of 60  
 
AD7177-2  
Data Sheet  
SPECIFICATIONS  
AVDD1 = 4.5 V to 5.5 V, AVDD2 = 2 V to 5.5 V, IOVDD = 2 V to 5.5 V, AVSS = DGND = 0 V, REF+ = 2.5 V, REF− = AVSS,  
internal master clock (MCLK) = 16 MHz, TA = TMIN to TMAX (−40°C to +105°C), unless otherwise noted.  
Table 1.  
Parameter  
Test Conditions/Comments  
Min  
Typ  
Max  
Unit  
ADC SPEED AND PERFORMANCE  
Output Data Rate (ODR)  
No Missing Codes1  
Resolution  
Noise  
FIR Filter Rejection  
ACCURACY  
5
32  
10,000  
SPS  
Bits  
See Table 19 to Table 23  
See Table 19 to Table 23  
See Table 23  
Integral Nonlinearity (INL)  
All input buffers disabled  
All input buffers enabled  
Internal short  
Internal short  
All input buffers disabled  
All input buffers enabled  
1
3.5  
7.8  
ppm of FSR  
ppm of FSR  
µV  
3.5  
40  
80  
45  
2.5  
0.4  
Offset Error2  
Offset Drift  
Gain Error2  
nV/°C  
100  
40  
0.75  
ppm of FSR  
ppm of FSR  
ppm/°C  
Gain Drift  
REJECTION  
Power Supply Rejection  
Common-Mode Rejection  
At DC  
AVDD1, AVDD2, VIN = 1 V  
VIN = 0.1 V  
95  
dB  
95  
120  
dB  
dB  
At 50 Hz, 60 Hz1  
20 Hz output data rate (post filter),  
50 Hz 1 Hz and 60 Hz 1 Hz  
50 Hz 1 Hz and 60 Hz 1 Hz  
Normal Mode Rejection1  
Internal clock, 20 SPS ODR (postfilter)  
External clock, 20 SPS ODR (postfilter)  
71  
85  
90  
90  
dB  
dB  
ANALOG INPUTS  
Differential Input Range  
Absolute Voltage Limits1  
Input Buffers Disabled  
Input Buffers Enabled  
Analog Input Current  
Input Buffers Disabled  
Input Current  
VREF = (REF+) − (REF−)  
VREF  
V
AVSS − 0.05  
AVSS  
AVDD1 + 0.05  
AVDD1  
V
V
48  
0.75  
4
µA/V  
nA/V/°C  
nA/V/°C  
Input Current Drift  
External clock  
Internal clock ( 2.5% clock)  
Input Buffers Enabled  
Input Current  
Input Current Drift  
30  
75  
1
nA  
AVDD1 − 0.2 V to AVSS + 0.2 V  
AVDD1 to AVSS  
1 kHz input  
pA/°C  
nA/°C  
dB  
Crosstalk  
−120  
INTERNAL REFERENCE  
Output Voltage  
100 nF external capacitor to AVSS  
REFOUT, with respect to AVSS  
REFOUT, TA = 25°C  
2.5  
V
Initial Accuracy3  
−0.12  
−10  
+0.12  
% of V  
Temperature Coefficient1  
0°C to 105°C  
−40°C to +105°C  
Reference Load Current, ILOAD  
Power Supply Rejection  
Load Regulation  
2
3
5
10  
+10  
ppm/°C  
ppm/°C  
mA  
dB  
ppm/mA  
AVDD1, AVDD2 (line regulation)  
∆VOUT/∆ILOAD  
90  
32  
Rev. B | Page 4 of 60  
 
Data Sheet  
AD7177-2  
Parameter  
Test Conditions/Comments  
eN, 0.1 Hz to 10 Hz, 2.5 V reference  
eN, 1 kHz, 2.5 V reference  
Min  
Typ  
4.5  
215  
200  
25  
Max  
Unit  
µV rms  
nV/√Hz  
µs  
Voltage Noise  
Voltage Noise Density  
Turn-On Settling Time  
Short-Circuit Current, ISC  
EXTERNAL REFERENCE INPUTS  
Differential Input Range  
Absolute Voltage Limits1  
Input Buffers Disabled  
Input Buffers Enabled  
REF+/REF− Input Current  
Input Buffers Disabled  
Input Current  
100 nF REFOUT capacitor  
mA  
VREF = (REF+) − (REF−)  
1
2.5  
AVDD1  
V
AVSS − 0.05  
AVSS  
AVDD1 + 0.05  
AVDD1  
V
V
72  
1.2  
6
µA/V  
nA/V/°C  
nA/V/°C  
Input Current Drift  
External clock  
Internal clock  
Input Buffers Enabled  
Input Current  
800  
nA  
Input Current Drift  
Normal Mode Rejection1  
Common-Mode Rejection  
TEMPERATURE SENSOR  
Accuracy  
1.25  
nA/°C  
See the Rejection parameter  
After user calibration at 25°C  
95  
dB  
2
°C  
Sensitivity  
470  
µV/K  
BURNOUT CURRENTS  
Source/Sink Current  
Analog input buffers must be enabled  
With respect to AVSS  
10  
µA  
GENERAL-PURPOSE I/O  
(GPIO0, GPIO1)  
Input Mode Leakage Current1  
Floating State Output  
Capacitance  
Output High Voltage, VOH  
Output Low Voltage, VOL  
Input High Voltage, VIH  
Input Low Voltage, VIL  
−10  
+10  
µA  
pF  
5
1
ISOURCE = 200 µA  
ISINK = 800 µA  
AVSS + 4  
AVSS + 3  
V
V
V
V
1
AVSS + 0.4  
AVSS + 0.7  
1
1
CLOCK  
Internal Clock  
Frequency  
Accuracy  
16  
50  
MHz  
%
%
V
V
−2.5%  
+2.5%  
0.4  
Duty Cycle  
Output Low Voltage, VOL  
Output High Voltage, VOH  
Crystal  
0.8 × IOVDD  
14  
Frequency  
16  
10  
16  
50  
16.384  
MHz  
µs  
MHz  
%
Start-Up Time  
External Clock (CLKIO)  
Duty Cycle1  
16.384  
70  
30  
Rev. B | Page 5 of 60  
AD7177-2  
Data Sheet  
Parameter  
Test Conditions/Comments  
Min  
Typ  
Max  
Unit  
LOGIC INPUTS  
Input High Voltage, VINH  
1
2 V ≤ IOVDD < 2.3 V  
2.3 V ≤ IOVDD ≤ 5.5 V  
2 V ≤ IOVDD < 2.3 V  
2.3 V ≤ IOVDD ≤ 5.5 V  
IOVDD ≥ 2.7 V  
0.65 × IOVDD  
0.7 × IOVDD  
V
V
V
V
V
1
Input Low Voltage, VINL  
0.35 × IOVDD  
0.7  
0.25  
0.2  
+10  
Hysteresis1  
0.08  
0.04  
−10  
IOVDD < 2.7 V  
V
µA  
Leakage Current  
LOGIC OUTPUT (DOUT/RDY)  
1
Output High Voltage, VOH  
IOVDD ≥ 4.5 V, ISOURCE = 1 mA  
2.7 V ≤ IOVDD < 4.5 V, ISOURCE = 500 µA  
IOVDD < 2.7 V, ISOURCE = 200 µA  
IOVDD ≥ 4.5 V, ISINK = 2 mA  
2.7 V ≤ IOVDD < 4.5 V, ISINK = 1 mA  
IOVDD < 2.7 V, ISINK = 400 µA  
Floating state  
0.8 × IOVDD  
0.8 × IOVDD  
0.8 × IOVDD  
V
V
V
V
V
V
µA  
pF  
1
Output Low Voltage, VOL  
0.4  
0.4  
0.4  
+10  
Leakage Current  
Output Capacitance  
SYSTEM CALIBRATION1  
Full-Scale (FS) Calibration Limit  
Zero-Scale Calibration Limit  
Input Span  
−10  
Floating state  
10  
1.05 × FS  
2.1 × FS  
V
V
V
−1.05 × FS  
0.8 × FS  
POWER REQUIREMENTS  
Power Supply Voltage  
AVDD1 to AVSS  
4.5  
2
−2.75  
2
5
5.5  
5.5  
0
5.5  
6.35  
V
V
V
V
V
AVDD2 to AVSS  
AVSS to DGND  
IOVDD to DGND  
IOVDD to AVSS  
2.5 to 5  
2.5 to 5  
For AVSS < DGND  
POWER SUPPLY CURRENTS4  
All outputs unloaded, digital inputs  
connected to IOVDD or DGND  
Full Operating Mode  
AVDD1 Current  
Analog input and reference input  
buffers disabled, external reference  
Analog input and reference input  
buffers disabled, internal reference  
Analog input and reference input  
buffers enabled, external reference  
1.4  
1.75  
13  
1.65  
2
mA  
mA  
mA  
16  
Each buffer: AIN+, AIN−, REF+, REF−  
External reference  
Internal reference  
External clock  
Internal clock  
External crystal  
Internal reference off, total current  
consumption  
Internal reference on, total current  
consumption  
Full power-down (including LDO and  
internal reference)  
2.9  
4.5  
4.75  
2.5  
2.75  
3
mA  
mA  
mA  
mA  
mA  
mA  
µA  
AVDD2 Current  
IOVDD Current  
5
5.2  
2.8  
3.1  
Standby Mode (LDO On)  
Power-Down Mode  
25  
425  
5
µA  
µA  
10  
Rev. B | Page 6 of 60  
Data Sheet  
AD7177-2  
Parameter  
Test Conditions/Comments  
Min  
Typ  
Max  
Unit  
POWER DISSIPATION4  
Full Operating Mode  
All buffers disabled, external clock and  
reference, AVDD2 = 2 V, IOVDD = 2 V  
All buffers disabled, external clock and  
reference, all supplies = 5 V  
All buffers disabled, external clock and  
reference, all supplies = 5.5 V  
All buffers enabled, internal clock and  
reference, AVDD2 = 2 V, IOVDD = 2 V  
All buffers enabled, internal clock and  
reference, all supplies = 5 V  
All buffers enabled, internal clock and  
reference, all supplies = 5.5 V  
Internal reference off, all supplies = 5 V  
Internal reference on, all supplies = 5 V  
Full power-down, all supplies = 5 V  
21  
42  
mW  
mW  
mW  
mW  
mW  
mW  
52  
82  
105  
136  
50  
Standby Mode  
125  
2.2  
25  
µW  
mW  
µW  
Power-Down Mode  
1 This specification is not production tested but is supported by characterization data at initial product release.  
2 Following a system or internal zero-scale calibration, the offset error is in the order of the noise for the programmed output data rate selected. A system full-scale  
calibration reduces the gain error to the order of the noise for the programmed output data rate.  
3 This specification includes moisture sensitivity level (MSL) preconditioning effects.  
4 This specification is with no load on the REFOUT and digital output pins.  
TIMING CHARACTERISTICS  
IOVDD = 2 V to 5.5 V, DGND = 0 V, Input Logic 0 = 0 V, Input Logic 1 = IOVDD, CLOAD = 20 pF, unless otherwise noted.  
Table 2.  
Parameter  
Limit at TMIN, TMAX  
Unit  
Description1, 2  
SCLK  
t3  
t4  
25  
25  
ns min  
ns min  
SCLK high pulse width  
SCLK low pulse width  
READ OPERATION  
t1  
0
ns min  
ns max  
ns max  
ns min  
ns max  
ns max  
ns min  
ns max  
ns min  
ns min  
CS falling edge to DOUT/RDY active time  
IOVDD = 4.75 V to 5.5 V  
IOVDD = 2 V to 3.6 V  
SCLK active edge to data valid delay4  
IOVDD = 4.75 V to 5.5 V  
IOVDD = 2 V to 3.6 V  
Bus relinquish time after CS inactive edge  
15  
40  
0
12.5  
25  
2.5  
20  
0
3
t2  
5
t5  
t6  
t7  
SCLK inactive edge to CS inactive edge  
10  
SCLK inactive edge to DOUT/RDY high/low  
WRITE OPERATION  
t8  
0
8
8
5
ns min  
ns min  
ns min  
ns min  
CS falling edge to SCLK active edge setup time4  
Data valid to SCLK edge setup time  
Data valid to SCLK edge hold time  
CS rising edge to SCLK edge hold time  
t9  
t10  
t11  
1 Sample tested during initial release to ensure compliance.  
2 See Figure 2 and Figure 3.  
3 This parameter is defined as the time required for the output to cross the VOL or VOH limits.  
4 The SCLK active edge is the falling edge of SCLK.  
5
RDY  
while DOUT/  
DOUT/  
returns high after a read of the data register. In single conversion mode and continuous conversion mode, the same data can be read again, if required,  
RDY  
is high, although care must be taken to ensure that subsequent reads do not occur close to the next output update. If the continuous read feature is  
enabled, the digital word can be read only once.  
Rev. B | Page 7 of 60  
 
 
AD7177-2  
Data Sheet  
Timing Diagrams  
CS (I)  
t6  
t1  
t5  
MSB  
LSB  
DOUT/RDY (O)  
t7  
t2  
t3  
SCLK (I)  
t4  
I = INPUT, O = OUTPUT  
Figure 2. Read Cycle Timing Diagram  
CS (I)  
t11  
t8  
SCLK (I)  
DIN (I)  
t9  
t10  
MSB  
LSB  
I = INPUT, O = OUTPUT  
Figure 3. Write Cycle Timing Diagram  
Rev. B | Page 8 of 60  
 
 
Data Sheet  
AD7177-2  
ABSOLUTE MAXIMUM RATINGS  
TA = 25°C, unless otherwise noted.  
THERMAL RESISTANCE  
θJA is specified for a device soldered on a JEDEC test board for  
surface-mount packages.  
Table 3.  
Parameter  
Rating  
AVDD1, AVDD2 to AVSS  
AVDD1 to DGND  
IOVDD to DGND  
IOVDD to AVSS  
−0.3 V to +6.5 V  
−0.3 V to +6.5 V  
−0.3 V to +6.5 V  
−0.3 V to +7.5 V  
−3.25 V to +0.3 V  
−0.3 V to AVDD1 + 0.3 V  
−0.3 V to AVDD1 + 0.3 V  
−0.3 V to IOVDD + 0.3 V  
−0.3 V to IOVDD + 0.3 V  
10 mA  
−40°C to +105°C  
−65°C to +150°C  
150°C  
260°C  
4 kV  
Table 4. Thermal Resistance  
Package Type  
θJA  
Unit  
24-Lead TSSOP  
JEDEC 1-Layer Board  
JEDEC 2-Layer Board  
149  
81  
°C/W  
°C/W  
AVSS to DGND  
Analog Input Voltage to AVSS  
Reference Input Voltage to AVSS  
Digital Input Voltage to DGND  
Digital Output Voltage to DGND  
Analog Input/Digital Input Current  
Operating Temperature Range  
Storage Temperature Range  
Maximum Junction Temperature  
Lead Soldering, Reflow Temperature  
ESD Rating (Human Body Model)  
ESD CAUTION  
Stresses at or above those listed under Absolute Maximum  
Ratings may cause permanent damage to the product. This is a  
stress rating only; functional operation of the product at these  
or any other conditions above those indicated in the operational  
section of this specification is not implied. Operation beyond  
the maximum operating conditions for extended periods may  
affect product reliability.  
Rev. B | Page 9 of 60  
 
 
 
AD7177-2  
Data Sheet  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
1
2
3
4
5
6
7
8
AIN4  
REF–  
AIN3  
AIN2  
REF+  
AIN1  
REFOUT  
REGCAPA  
AVSS  
AIN0  
GPIO1  
GPIO0  
REGCAPD  
DGND  
IOVDD  
SYNC/ERROR  
CS  
AD7177-2  
TOP VIEW  
(Not to Scale)  
AVDD1  
AVDD2  
9
XTAL1  
10  
11  
12  
XTAL2/CLKIO  
DOUT/RDY  
DIN  
SCLK  
Figure 4. Pin Configuration  
Table 5. Pin Function Descriptions1  
Pin No.  
Mnemonic  
Type 2  
AI  
AI  
AI  
Description  
1
2
3
AIN4  
REF−  
REF+  
Analog Input 4. This pin is electable through the crosspoint multiplexer.  
Reference Input Negative Terminal. REF− can span from AVSS to AVDD1 − 1 V.  
Reference Input Positive Terminal. An external reference can be applied between REF+ and REF−. REF+  
can span from AVSS + 1 V to AVDD1. The device functions with a reference magnitude from 1 V to AVDD1.  
4
5
REFOUT  
REGCAPA  
AO  
AO  
Buffered Output of Internal Reference. The output is 2.5 V with respect to AVSS.  
Analog Low Dropout (LDO) Regulator Output. Decouple this pin to AVSS using a 1 µF and a 0.1 µF  
capacitor.  
6
7
AVSS  
AVDD1  
P
P
Negative Analog Supply. This supply ranges from −2.75 V to 0 V and is nominally set to 0 V.  
Analog Supply Voltage 1. This voltage is 5 V 10% with respect to AVSS. AVDD1 − AVSS can be a single  
5 V supply or a 2.5 V split supply.  
8
9
AVDD2  
XTAL1  
P
AI  
Analog Supply Voltage 2. This voltage ranges from 2 V to 5 V with respect to AVSS.  
Input 1 for Crystal.  
10  
XTAL2/CLKIO  
AI/DI  
Input 2 for Crystal/Clock Input or Output. The functionality of this pin is based on the CLOCKSEL bits in  
the ADCMODE register. There are four options available for selecting the MCLK source:  
Internal oscillator: no output.  
Internal oscillator: output to XTAL2/CLKIO. Operates at IOVDD logic level.  
External clock: input to XTAL2/CLKIO. Input must be at IOVDD logic level.  
External crystal: connected between XTAL1 and XTAL2/CLKIO.  
11  
DOUT/RDY  
DO  
Serial Data Output/Data Ready Output. DOUT/RDY is a dual purpose pin. It functions as a serial data  
output pin to access the output shift register of the ADC. The output shift register can contain data  
from any of the on-chip data or control registers. The data-word/control word information is placed on  
the DOUT/RDY pin on the SCLK falling edge and is valid on the SCLK rising edge. When CS is high, the  
DOUT/RDY output is three-stated. When CS is low, DOUT/RDY operates as a data ready pin, going low  
to indicate the completion of a conversion. If the data is not read after the conversion, the pin goes  
high before the next update occurs. The DOUT/RDY falling edge can be used as an interrupt to a  
processor, indicating that valid data is available.  
12  
DIN  
DI  
Serial Data Input to the Input Shift Register on the ADC. Data in this shift register is transferred to the  
control registers in the ADC, with the register address (RA) bits of the communications register  
identifying the appropriate register. Data is clocked in on the rising edge of SCLK.  
13  
14  
SCLK  
CS  
DI  
DI  
Serial Clock Input. This serial clock input is for data transfers to and from the ADC. The SCLK pin has a  
Schmitt triggered input, making the interface suitable for opto-isolated applications.  
Chip Select Input. This pin is an active low logic input used to select the ADC. CS can be used to select  
the ADC in systems with more than one device on the serial bus. CS can be hardwired low, allowing the  
ADC to operate in 3-wire mode with SCLK, DIN, and DOUT used to interface with the device. When CS  
is high, the DOUT/RDY output is three-stated.  
Rev. B | Page 10 of 60  
 
Data Sheet  
AD7177-2  
Pin No.  
Mnemonic  
SYNC/ERROR  
Type 2  
Description  
15  
DI/O  
Synchronization Input/Error Input or Output. This pin can be switched between a logic input and a  
logic output in the GPIOCON register. When the synchronization input (SYNC) is enabled, this pin  
allows synchronization of the digital filters and analog modulators when using multiple AD7177-2  
devices. For more information, see the Synchronization section. When the synchronization input is  
disabled, this pin can be used in one of three modes:  
Active low error input mode: this mode sets the ADC_ERROR bit in the status register.  
Active low, open-drain error output mode: the status register error bits are mapped to the ERROR  
output. The SYNC/ERROR pins of multiple devices can be wired together to a common pull-up resistor  
so that an error on any device can be observed.  
General-purpose output mode: the status of the pin is controlled by the ERR_DAT bit in the GPIOCON  
register. The pin is referenced between IOVDD and DGND, as opposed to the AVDD1 and AVSS levels  
used by the GPIOx pins. The pin has an active pull-up circuit in this case.  
16  
IOVDD  
P
Digital I/O Supply Voltage. The IOVDD voltage ranges from 2 V to 5.5 V. IOVDD is independent of  
AVDD2. For example, IOVDD can be operated at 3 V when AVDD2 equals 5 V, or vice versa. If AVSS is  
set to −2.5 V, the voltage on IOVDD must not exceed 3.6 V.  
17  
18  
DGND  
REGCAPD  
P
AO  
Digital Ground.  
Digital LDO Regulator Output. This pin is for decoupling purposes only. Decouple this pin to DGND  
using a 1 µF and a 0.1 µF capacitor.  
19  
20  
21  
22  
23  
24  
GPIO0  
GPIO1  
AIN0  
AIN1  
AIN2  
AIN3  
DI/O  
DI/O  
AI  
AI  
AI  
General-Purpose Input/Output 0. The pin is referenced between AVDD1 and AVSS levels.  
General-Purpose Input/Output 1. The pin is referenced between AVDD1 and AVSS levels.  
Analog Input 0. This pin is selectable through the crosspoint multiplexer.  
Analog Input 1. This pin is selectable through the crosspoint multiplexer.  
Analog Input 2. This pin is selectable through the crosspoint multiplexer.  
Analog Input 3. This pin is selectable through the crosspoint multiplexer.  
AI  
1 Note that, throughout this data sheet, the dual function pin names are referenced by the relevant function only.  
2 AI is analog input, AO is analog output, P is power supply, DI is digital input, DO is digital output, and DI/O is bidirectional digital input/output.  
Rev. B | Page 11 of 60  
 
AD7177-2  
Data Sheet  
TYPICAL PERFORMANCE CHARACTERISTICS  
AVDD1 = 5 V, AVDD2 = 5 V, IOVDD = 3.3 V, TA = 25°C, unless otherwise noted.  
2147454000  
2147453950  
2147453900  
2147453850  
2147453800  
2147453750  
2147453700  
160  
140  
120  
100  
80  
60  
40  
20  
0
SAMPLE NUMBER  
ADC CODE  
Figure 8. Histogram (Analog Input Buffers Disabled, VREF = 5 V,  
Output Data Rate = 5 SPS, 32-Bit Data Output)  
Figure 5. Noise (Analog Input Buffers Disabled, VREF = 5 V,  
Output Data Rate = 5 SPS, 32-Bit Data Output)  
140  
120  
100  
80  
2147458000  
2147457000  
2147456000  
2147455000  
2147454000  
2147453000  
2147452000  
2147451000  
2147450000  
2147449000  
2147448000  
2147447000  
60  
40  
20  
0
SAMPLE NUMBER  
ADC CODE  
Figure 6. Noise (Analog Input Buffers Disabled, VREF = 5 V,  
Output Data Rate = 10 kSPS, 32-Bit Data Output)  
Figure 9. Histogram (Analog Input Buffers Disabled, VREF = 5 V,  
Output Data Rate = 10 kSPS, 32-Bit Data Output)  
160  
140  
120  
100  
80  
2147456250  
2147456200  
2147456150  
2147456100  
2147456050  
2147456000  
2147455950  
2147455900  
2147455850  
60  
40  
20  
0
SAMPLE NUMBER  
ADC CODE  
Figure 10. Histogram (Analog Input Buffers Enabled, VREF = 5 V,  
Output Data Rate = 5 SPS)  
Figure 7. Noise (Analog Input Buffers Enabled, VREF = 5 V,  
Output Data Rate = 5 SPS)  
Rev. B | Page 12 of 60  
 
Data Sheet  
AD7177-2  
2147462000  
2147460000  
2147458000  
2147456000  
2147454000  
2147452000  
2147450000  
2147448000  
160  
140  
120  
100  
80  
60  
40  
20  
0
SAMPLE NUMBER  
ADC CODE  
Figure 11. Noise (Analog Input Buffers Enabled, VREF = 5 V,  
Output Data Rate = 10 kSPS)  
Figure 14. Histogram (Analog Input Buffers Enabled, VREF = 5 V,  
Output Data Rate = 10 kSPS)  
16800000  
10  
CONTINUOUS CONVERSION—REFERENCE DISABLED  
STANDBY—REFERENCE DISABLED  
9
8
7
6
5
4
3
2
1
0
STANDBY—REFERENCE ENABLED  
16780000  
16760000  
16740000  
16720000  
16700000  
16680000  
16660000  
ANALOG INPUT BUFFERS ON  
ANALOG INPUT BUFFERS OFF  
0
1
2
3
4
5
1
10  
100  
1k  
10k  
INPUT COMMON-MODE VOLTAGE (V)  
SAMPLE NUMBER  
Figure 12. Noise vs. Input Common-Mode Voltage, Analog Input Buffers On  
and Off  
Figure 15. Internal Reference Settling Time  
0
–20  
10  
9
8
7
–40  
6
5
–60  
4
ANALOG INPUT BUFFERS ON  
3
–80  
ANALOG INPUT BUFFERS OFF  
2
1
0
–100  
–120  
1
0
2
4
6
8
10  
12  
14  
16  
10  
100  
1k  
10k  
100k  
1M  
FREQUENCY (MHz)  
V
FREQUENCY (Hz)  
IN  
Figure 13. Noise vs. External Master Clock Frequency,  
Analog Input Buffers On and Off  
Figure 16. Common-Mode Rejection Ratio (CMRR) vs. VIN Frequency  
(VIN = 0.1 V)  
Rev. B | Page 13 of 60  
 
AD7177-2  
Data Sheet  
30  
25  
20  
15  
10  
5
–80  
–90  
–100  
–110  
–120  
–130  
–140  
–150  
–160  
–170  
0
–180  
10  
2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00  
INL ERROR (ppm)  
20  
30  
V
40  
50  
60  
70  
FREQUENCY (Hz)  
IN  
Figure 17. Common-Mode Rejection Ratio (CMRR) vs. VIN Frequency  
(VIN = 0.1 V, 10 Hz to 70 Hz, Output Data Rate = 20 SPS, Enhanced Filter)  
Figure 20. Integral Nonlinearity (INL) Distribution Histogram (Differential  
Input, All Input Buffers Enabled, VREF = 2.5 V External, 100 Units)  
–60  
30  
25  
20  
15  
10  
5
AVDD1—EXTERNAL 2.5V REFERENCE  
AVDD1—INTERNAL 2.5V REFERENCE  
–70  
–80  
–90  
–100  
–110  
–120  
–130  
0
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
1
10  
100  
1k  
10k  
100k  
1M  
10M  
100M  
INL ERROR (ppm)  
V
FREQUENCY (Hz)  
IN  
Figure 21. Integral Nonlinearity (INL) Distribution Histogram (Differential  
Input, All Input Buffers Disabled, VREF = 2.5 V External, 100 Units)  
Figure 18. Power Supply Rejection Ratio (PSRR) vs. VIN Frequency  
30  
25  
20  
15  
10  
5
20  
INTERNAL 2.5V REF,  
ANALOG INPUT BUFFERS OFF  
INTERNAL 2.5V REF,  
ANALOG INPUT BUFFERS ON  
EXTERNAL 2.5V REF,  
ANALOG INPUT BUFFERS OFF  
EXTERNAL 2.5V REF,  
ANALOG INPUT BUFFERS ON  
EXTERNAL 5V REF,  
ANALOG INPUT BUFFERS OFF  
EXTERNAL 5V REF,  
ANALOG INPUT BUFFERS ON  
15  
10  
5
0
–5  
–10  
–15  
–20  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
4.5  
5.0  
–5  
–4  
–3  
–2  
–1  
0
1
2
3
4
5
INL ERROR (ppm)  
V
(V)  
IN  
Figure 22. Integral Nonlinearity (INL) Distribution Histogram (All Input  
Buffers Enabled, Differential Input, VREF = 5 V External, 100 Units)  
Figure 19. Integral Nonlinearity (INL) vs. VIN  
(Differential Input)  
Rev. B | Page 14 of 60  
 
Data Sheet  
AD7177-2  
16400000  
16300000  
16200000  
16100000  
16000000  
15900000  
15800000  
15700000  
15600000  
30  
25  
20  
15  
10  
5
0
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
–40  
–20  
0
20  
40  
60  
80  
100  
INL ERROR (ppm)  
TEMPERATURE (°C)  
Figure 23. Integral Nonlinearity (INL) Distribution Histogram (All Input  
Buffers Disabled, Differential Input, VREF = 5 V External, 100 Units)  
Figure 26. Internal Oscillator Frequency vs. Temperature  
0.0010  
5.0  
BUFFER DISABLED  
BUFFER ENABLED  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0
0.0005  
0
–0.0005  
–0.0010  
–40  
–20  
0
20  
40  
60  
80  
100  
–40  
–20  
0
20  
40  
60  
80  
100  
TEMPERATURE (°C)  
TEMPERATURE (°C)  
Figure 24. Integral Nonlinearity (INL) vs. Temperature  
(Differential Input, VREF = 2.5 V External)  
Figure 27. Absolute Reference Error vs. Temperature  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
0
0
15.98 15.99 16.00 16.01 16.02 16.03 16.04 16.05  
FREQUENCY (MHz)  
–40 –30 –20 –10  
0
10 20 30 40 50 60 70 80 90  
OFFSET ERROR (µV)  
Figure 25. Internal Oscillator Frequency/Accuracy Distribution Histogram  
(100 Units)  
Figure 28. Offset Error Distribution Histogram (Internal Short, 248 Units)  
Rev. B | Page 15 of 60  
AD7177-2  
Data Sheet  
35  
30  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
0
0
OFFSET DRIFT ERROR (nV/°C)  
GAIN ERROR DRIFT (ppm/FSR)  
Figure 29. Offset Error Drift Distribution Histogram (Internal Short, 248 Units)  
Figure 32. Gain Error Drift Distribution Histogram  
(All Input Buffers Enabled, 100 Units)  
40  
35  
30  
25  
20  
15  
10  
5
40  
35  
30  
25  
20  
15  
10  
5
0
0
–4  
–3  
–2  
–1  
0
1
2
3
4
0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55  
GAIN ERROR DRIFT (ppm/FSR)  
GAIN ERROR (ppm/FSR)  
Figure 30. Gain Error Distribution Histogram (All Input Buffers Enabled, 100 Units)  
Figure 33. Gain Error Drift Distribution Histogram  
(All Input Buffers Disabled, 100 Units)  
0.025  
0.020  
0.015  
0.010  
0.005  
0
30  
25  
20  
15  
10  
5
BUFFERS DISABLED  
BUFFERS ENABLED  
0
–40  
–20  
0
20  
40  
60  
80  
100  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
GAIN ERROR (ppm/FSR)  
TEMPERATURE (°C)  
Figure 34. Supply Current vs. Temperature  
(Continuous Conversion Mode)  
Figure 31. Gain Error Distribution Histogram  
(All Input Buffers Disabled, 100 Units)  
Rev. B | Page 16 of 60  
Data Sheet  
AD7177-2  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
100  
80  
–40°C, AIN+  
–40°C, AIN–  
+25°C, AIN+  
+25°C, AIN–  
+105°C, AIN+  
+105°C, AIN–  
60  
40  
20  
0
–20  
–40  
–60  
–80  
–100  
–40  
–20  
0
20  
40  
60  
80  
100  
–5  
–4  
–3  
–2  
–1  
0
1
2
3
4
5
TEMPERATURE (°C)  
INPUT VOLTAGE (V)  
Figure 35. Supply Current vs. Temperature (Power-Down Mode)  
Figure 38. Analog Input Current vs. Input Voltage  
(VCM = 2.5 V, All Input Buffers Enabled)  
18  
16  
14  
12  
10  
8
100  
AIN+ = AVDD1 – 0.2V  
AIN– = AVSS + 0.2V  
AIN+ = AVDD1  
80  
60  
AIN– = AVSS  
40  
20  
0
–20  
–40  
–60  
–80  
–100  
6
4
2
0
–40  
–20  
0
20  
40  
60  
80  
100  
–1.2 –1.0 –0.8 –0.6 –0.4 –0.2  
0
0.2 0.4 0.6 0.8 1.0  
TEMPERATURE DELTA (°C)  
TEMPERATURE (°C)  
Figure 36. Temperature Sensor Distribution Histogram  
(Uncalibrated, 100 Units)  
Figure 39. Analog Input Current vs. Temperature  
(All Input Buffers Enabled)  
35  
30  
25  
20  
15  
10  
5
0
9.60 9.65 9.70 9.75 9.80 9.85 9.90 9.95 10.00 10.05 10.10  
CURRENT (µA)  
Figure 37. Burnout Current Distribution Histogram  
(100 Units)  
Rev. B | Page 17 of 60  
 
 
AD7177-2  
Data Sheet  
NOISE PERFORMANCE AND RESOLUTION  
Table 6 and Table 7 show the rms noise, peak-to-peak noise,  
effective resolution, and the noise free (peak-to-peak)  
resolution of the AD7177-2 for various output data rates and  
filters. The numbers given are for the bipolar input range with  
an external 5 V reference. These numbers are typical and are  
generated with a differential input voltage of 0 V when the ADC  
is continuously converting on a single channel. It is important  
to note that the peak-to-peak resolution is calculated based on  
the peak-to-peak noise. The peak-to-peak resolution represents  
the resolution for which there is no code flicker.  
Table 6. RMS Noise and Peak-to-Peak Resolution vs. Output Data Rate Using a Sinc5 + Sinc1 Filter (Default)1  
Output Data Rate (SPS)  
RMS Noise (µV rms)  
Effective Resolution (Bits)  
Peak-to-Peak Noise (µV p-p) Peak-to-Peak Resolution (Bits)  
Input Buffers Disabled  
10,000  
1000  
59.92  
49.96  
16.66  
5
2.5  
21.9  
23.6  
25.8  
26  
26.7  
27.3  
18.3  
5.2  
1.1  
0.95  
0.45  
0.34  
19.1  
20.9  
23.1  
23.3  
24.1  
24.6  
0.77  
0.19  
0.18  
0.1  
0.07  
Input Buffers Enabled  
10,000  
1000  
59.98  
49.96  
16.66  
5
3
21.7  
23.4  
25.7  
26  
26.6  
26.7  
23  
18.7  
20.7  
23.0  
23.3  
23.9  
24.6  
0.92  
0.23  
0.2  
0.13  
0.07  
5.7  
1.2  
1
0.66  
0.32  
1 Selected rates only, 1000 samples.  
Table 7. RMS Noise and Peak-to-Peak Resolution vs. Output Data Rate Using a Sinc3 Filter1  
Output Data Rate (SPS)  
RMS Noise (µV rms)  
Effective Resolution (Bits)  
Peak-to-Peak Noise (µV p-p) Peak-to-Peak Resolution (Bits)  
Input Buffers Disabled  
10,000  
1000  
60  
50  
16.66  
5
1.8  
22.4  
24  
26.3  
26.5  
27  
14  
3.9  
0.8  
0.7  
0.37  
0.21  
19.4  
21.3  
23.6  
23.8  
24.3  
24.8  
0.56  
0.13  
0.13  
0.07  
0.05  
27.5  
Input Buffers Enabled  
10,000  
1000  
60  
50  
16.66  
5
2.1  
22.2  
23.7  
25.8  
26.2  
26.8  
27.2  
24  
16  
4.5  
1.1  
0.83  
0.6  
19.3  
21.1  
23.1  
23.5  
24.1  
24.5  
24  
0.71  
0.17  
0.15  
0.12  
0.08  
0.08  
0.35  
0.35  
5
1 Selected rates only, 1000 samples.  
Rev. B | Page 18 of 60  
 
 
 
Data Sheet  
AD7177-2  
GETTING STARTED  
The AD7177-2 offers the user a fast settling, high resolution,  
multiplexed ADC with high levels of configurability. The  
AD7177-2 includes the following features:  
The AD7177-2 includes a precision 2.5 V low drift ( 2 ppm/°C)  
band gap internal reference. This reference can be used for the  
ADC conversions, reducing the external component count.  
Alternatively, the reference can be output to the REFOUT pin to  
be used as a low noise biasing voltage for external circuitry. An  
example of this is using the REFOUT signal to set the input  
common mode for an external amplifier.  
Two fully differential or four single-ended analog inputs.  
A crosspoint multiplexer selects any analog input combina-  
tion as the input signals to be converted, routing them to  
the modulator positive or negative input.  
The AD7177-2 includes two separate linear regulator blocks for  
both the analog and digital circuitry. The analog LDO regulates  
the AVDD2 supply to 1.8 V, supplying the ADC core. The user  
can tie the AVDD1 and AVDD2 supplies together for an easy  
connection. If there is already a clean analog supply rail in the  
system in the range of 2 V (minimum) to 5.5 V (maximum), the  
user can also choose to connect this to the AVDD2 input,  
allowing lower power dissipation.  
True rail-to-rail buffered analog and reference inputs.  
Fully differential input or single-ended input relative to any  
analog input.  
Per channel configurability—up to four different setups  
can be defined. A separate setup can be mapped to each of  
the channels. Each setup allows the user to configure  
whether the buffers are enabled or disabled, gain and offset  
correction, filter type, output data rate, and reference  
source selection (internal/external).  
GENERAL-PURPOSE I/O 0 AND  
GENERAL-PURPOSE I/O 1  
OUTPUT HIGH = AVDDx  
OUTPUT LOW = AVSS  
GPIO0  
GPIO1  
16MHz  
20  
19  
CX2  
CX1  
GPIO0  
GPIO1  
OPTIONAL EXTERNAL  
CRYSTAL CIRCUITRY  
CAPACITORS  
9
XTAL1  
21  
AIN0  
10  
XTAL2/CLKIO  
CLKIN  
OPTIONAL  
EXTERNAL  
CLOCK  
INPUT  
DOUT/RDY 11  
DOUT/RDY  
DIN  
22  
23  
AIN1  
AIN2  
12  
DIN  
13  
SCLK  
CS  
SCLK  
14  
15  
CS  
SYNC/ERROR  
SYNC/ERROR  
IOVDD  
24  
1
AIN3  
AIN4  
AD7177-2  
16  
17  
IOVDD  
DGND  
0.1µF  
1
3
V
IN  
TP  
NC  
REGCAPD 18  
2
4
7
6
V
NC  
IN  
0.1µF  
1µF  
AVDD1  
4.7µF  
0.1µF  
ADR445  
AVDD1  
AVDD2  
7
8
5
0.1µF  
3
GND  
V
REF+  
REF–  
OUT  
AVDD2  
0.1µF  
4.7µF  
0.1µF  
0.1µF  
TRIM  
5
TP  
8
2
4
0.1µF  
REFOUT  
REGCAPA  
2.5V REFERENCE  
OUTPUT  
0.1µF  
1µF  
AVSS  
6
0.1µF  
Figure 40. Typical Connection Diagram  
Rev. B | Page 19 of 60  
 
AD7177-2  
Data Sheet  
The linear regulator for the digital IOVDD supply performs a  
similar function, regulating the input voltage applied at the  
IOVDD pin to 1.8 V for the internal digital filtering. The serial  
interface signals always operate from the IOVDD supply seen at  
the pin. This means that if 3.3 V is applied to the IOVDD pin,  
the interface logic inputs and outputs operate at this level.  
DRIVE EDGE  
SAMPLE EDGE  
Figure 41. SPI Mode 3 SCLK Edges  
The AD7177-2 can be used across a wide variety of applications,  
providing high resolution and accuracy. A sample of these  
scenarios is as follows:  
Accessing the ADC Register Map  
The communications register controls access to the full register  
map of the ADC. This register is an 8-bit write only register. On  
power-up or after a reset, the digital interface defaults to a state  
where it is expecting a write to the communications register;  
therefore, all communication begins by writing to the  
communications register.  
Fast scanning of analog input channels using the internal  
multiplexer  
Fast scanning of analog input channels using an external  
multiplexer with automatic control from the GPIOs.  
High resolution at lower speeds in either channel scanning  
or ADC per channel applications  
Single ADC per channel. The fast low latency output allows  
further application specific filtering in an external micro-  
controller, DSP, or FPGA  
The data written to the communications register determines  
which register is being accessed and if the next operation is a  
read or write. The register address bits (RA[5:0]) determine the  
specific register to which the read or write operation applies.  
When the read or write operation to the selected register is  
complete, the interface returns to its default state, where it  
expects a write operation to the communications register.  
POWER SUPPLIES  
The AD7177-2 has three independent power supplies: AVDD1,  
AVDD2, and IOVDD.  
Figure 42 and Figure 43 illustrate writing to and reading from a  
register by first writing the 8-bit command to the communications  
register, followed by the data for that register.  
AVDD1 powers the crosspoint multiplexer and integrated analog  
and reference input buffers. AVDD1 is referenced to AVSS, and  
AVDD1 − AVSS = 5 V only. AVDD1 − AVSS can be a single 5 V  
supply or a 2.5 V split supply. The split supply operation allows  
true bipolar inputs. When using split supplies, consider the absolute  
maximum ratings (see the Absolute Maximum Ratings section).  
8 BITS, 16 BITS,  
OR 24 BITS OF DATA  
8-BIT COMMAND  
CS  
AVDD2 powers the internal 1.8 V analog LDO regulator. This  
regulator powers the ADC core. AVDD2 is referenced to AVSS,  
and AVDD2 − AVSS can range from to 2 V (minimum) to 5.5 V  
(maximum).  
CMD  
DATA  
DIN  
SCLK  
IOVDD powers the internal 1.8 V digital LDO regulator. This  
regulator powers the digital logic of the ADC. IOVDD sets the  
voltage levels for the SPI interface of the ADC. IOVDD is refer-  
enced to DGND, and IOVDD − DGND can vary from 2 V  
(minimum) to 5.5 V (maximum).  
Figure 42. Writing to a Register  
(8-Bit Command with Register Address Followed by Data of 8 Bits, 16 Bits, or  
24 Bits; Data Length on DIN Is Dependent on the Register Selected)  
8 BITS, 16 BITS,  
24 BITS, OR  
32 BITS OUTPUT  
There is no specific requirement for a power supply sequence on  
the AD7177-2. When all power supplies are stable, a device reset is  
required; see the AD7177-2 Reset section for details on how to  
reset the device.  
8-BIT COMMAND  
CS  
DIGITAL COMMUNICATION  
CMD  
DIN  
The AD7177-2 has a 3- or 4-wire SPI interface that is compatible  
with QSPI™, MICROWIRE®, and DSPs. The interface operates  
CS  
in SPI Mode 3 and can be operated with  
tied low. In SPI  
DOUT/RDY  
DATA  
Mode 3, SCLK idles high, the falling edge of SCLK is the drive  
edge, and the rising edge of SCLK is the sample edge. This  
means that data is clocked out on the falling/drive edge and data  
is clocked in on the rising/sample edge.  
SCLK  
Figure 43. Reading from a Register  
(8-Bit Command with Register Address Followed by Data of 8 Bits, 16 Bits, or  
24 Bits; Data Length on DOUT Is Dependent on the Register Selected)  
Rev. B | Page 20 of 60  
 
 
 
 
Data Sheet  
AD7177-2  
Reading the ID register is the recommended method for verifying  
correct communication with the device. The ID register is a  
read only register and contains the value 0x4FDX for the  
AD7177-2. The communications register and the ID register  
details are described in Table 8 and Table 9, respectively.  
Figure 44 shows an overview of the suggested flow for changing  
the ADC configuration, divided into the following three blocks:  
Channel configuration (see Box A in Figure 44)  
Setup configuration (see Box B in Figure 44)  
ADC mode and interface mode configuration (see Box C  
in Figure 44)  
AD7177-2 RESET  
In situations where interface synchronization is lost, a write  
operation of at least 64 serial clock cycles with DIN high returns the  
ADC to its default state by resetting the entire device, including  
Channel Configuration  
The AD7177-2 has four independent channels and four independ-  
ent setups. The user can select any of the analog input pairs on  
any channel, as well as any of the four setups for any channel,  
giving the user full flexibility in the channel configuration. This  
also allows per channel configuration when using differential  
inputs and single-ended inputs because each channel can have  
its own dedicated setup.  
CS  
the register contents. Alternatively, if  
is being used with the  
CS  
digital interface, returning  
high sets the digital interface to its  
default state and halts any serial interface operation.  
CONFIGURATION OVERVIEW  
After power-on or reset, the AD7177-2 default configurations  
are as follows. Note that only a few of the register setting  
options are shown; this list is just an example. For full register  
information, see the Register Details section.  
Channel Registers  
The channel registers are used to select which of the five analog  
input pins (AIN0 to AIN4) are used as either the positive analog  
input (AIN+) or the negative analog input (AIN−) for that  
channel. This register also contains a channel enable/disable bit  
and the setup selection bits, which are used to select from the  
four available setups for this channel.  
Channel configuration. CH0 is enabled, AIN0 is selected  
as the positive input, and AIN1 is selected as the negative  
input. Setup 0 is selected.  
Setup configuration. The internal reference and the analog  
input buffers are enabled. The reference input buffers are  
disabled.  
When the AD7177-2 is operating with more than one channel  
enabled, the channel sequencer cycles through the enabled  
channels in sequential order, from Channel 0 to Channel 3. If a  
channel is disabled, it is skipped by the sequencer. Details of the  
channel register for Channel 0 are shown in Table 10.  
Filter configuration. The sinc5 + sinc 1 filter is selected and  
the maximum output data rate of 10 kSPS is selected.  
ADC mode. Continuous conversion mode and the internal  
oscillator are enabled.  
Interface mode. CRC and the data + status output are disabled.  
A
B
C
CHANNEL CONFIGURATION  
SELECT POSITIVE AND NEGATIVE INPUT FOR EACH ADC CHANNEL  
SELECT ONE OF 4 SETUPS FOR ADC CHANNEL  
SETUP CONFIGURATION  
4 POSSIBLE ADC SETUPS  
SELECT FILTER ORDER, OUTPUT DATA RATE, AND MORE  
ADC MODE AND INTERFACE MODE CONFIGURATION  
SELECT ADC OPERATING MODE, CLOCK SOURCE,  
ENABLE CRC, DATA + STATUS, AND MORE  
Figure 44. Suggested ADC Configuration Flow  
Rev. B | Page 21 of 60  
 
 
 
 
AD7177-2  
Data Sheet  
Table 8. Communications Register  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 5  
Bit 4  
Bit 4  
Bit 3  
Bit 3  
Bit 2  
Bit 2  
Bit 1  
Bit 1  
Bit 0  
Bit 0  
Reset  
RW  
0x00  
COMMS [7:0]  
RA  
0x00  
W
WEN  
R/W  
Table 9. ID Register  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Reset  
RW  
0x07  
ID  
[15:8]  
[7:0]  
ID[15:8]  
ID[7:0]  
0x4FDX  
R
Table 10. Channel 0 Register  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reset  
RW  
0x10  
CH0  
[15:8] CH_EN0  
[7:0]  
Reserved  
AINPOS0[2:0]  
SETUP_SEL[2:0]  
Reserved  
AINNEG0  
AINPOS0[4:3]  
0x8001  
RW  
Rev. B | Page 22 of 60  
 
 
 
Data Sheet  
AD7177-2  
Setup Configuration Registers  
ADC Setups  
The setup configuration registers allow the user to select the output  
coding of the ADC by selecting between bipolar and unipolar. In  
bipolar mode, the ADC accepts negative differential input voltages,  
and the output coding is offset binary. In unipolar mode, the ADC  
accepts only positive differential voltages, and the coding is straight  
binary. In either case, the input voltage must be within the AVDD1/  
AVSS supply voltages. The user can select the reference source  
using these registers. Three options are available: an internal  
2.5 V reference, an external reference connected between the  
REF+ and REF− pins, or AVDD1 − AVSS. The analog input and  
reference input buffers can also be enabled or disabled using  
this register.  
The AD7177-2 has four independent setups. Each setup consists  
of the following four registers:  
Setup configuration register  
Filter configuration register  
Gain register  
Offset register  
For example, Setup 0 consists of Setup Configuration Register 0,  
Filter Configuration Register 0, Gain Register 0, and Offset  
Register 0. Figure 45 shows the grouping of these registers. The  
setup is selectable from the channel registers (see the Channel  
Configuration section), which allows each channel to be  
assigned to one of four separate setups. Table 11 through Table 14  
show the four registers associated with Setup 0. This structure is  
repeated for Setup 1 to Setup 3.  
Filter Configuration Registers  
The filter configuration registers select which digital filter is  
used at the output of the ADC modulator. The order of the filter  
and the output data rate is selected by setting the bits in this  
register. For more information, see the Digital Filters section.  
SETUP CONFIG  
REGISTERS  
FILTER CONFIG  
REGISTERS  
GAIN REGISTERS*  
OFFSET REGISTERS  
SETUPCON0  
SETUPCON1  
SETUPCON2  
SETUPCON3  
FILTCON0  
FILTCON1  
FILTCON2  
FILTCON3  
GAIN0  
GAIN1  
GAIN2  
GAIN3  
OFFSET0  
0x30  
0x20  
0x21  
0x22  
0x23  
0x28  
0x29  
0x2A  
0x2B  
0x38  
0x39  
0x3A  
0x3B  
OFFSET1  
0x31  
OFFSET2  
0x32  
OFFSET3  
0x33  
SELECT PERIPHERAL  
FUNCTIONS FOR  
ADC CHANNEL  
SELECT DIGITAL  
FILTER TYPE  
GAIN CORRECTION  
OPTIONALLY  
OFFSET CORRECTION  
OPTIONALLY PROGRAMMED  
PER SETUP AS REQUIRED  
AND OUTPUT DATA RATE  
PROGRAMMED  
PER SETUP AS REQUIRED  
(*FACTORY CALIBRATED)  
DATA OUTPUT CODING  
REFERENCE SOURCE  
INPUT BUFFERS  
SINC5 + SINC1  
SINC3  
SINC3 MAP  
ENHANCED 50Hz AND 60Hz  
Figure 45. ADC Setup Register Grouping  
Table 11. Setup Configuration 0 Register  
Reg. Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reset  
RW  
0x20 SETUPCON0 [15:8]  
Reserved  
BI_UNIPOLAR0 REFBUF0+ REFBUF0− AINBUF0+ AINBUF0− 0x1320  
RW  
[7:0] BURNOUT_EN0 Reserved  
REF_SEL0  
Reserved  
Table 12. Filter Configuration 0 Register  
Reg. Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reset  
RW  
0x28 FILTCON0 [15:8] SINC3_MAP0  
[7:0] Reserved  
Reserved  
ORDER0  
ENHFILTEN0  
ENHFILT0  
0x0507  
RW  
ODR0  
Table 13. Gain Configuration 0 Register  
Reg. Name  
Bits  
Bits[23:0]  
Reset  
RW  
0x38 GAIN0  
[23:0]  
GAIN0[23:0]  
0x5XXXX0 RW  
Table 14. Offset Configuration 0 Register  
Reg. Name  
Bits  
Bits[23:0]  
Reset  
RW  
0x30 OFFSET0  
[23:0]  
OFFSET0[23:0]  
0x800000 RW  
Rev. B | Page 23 of 60  
 
 
 
 
AD7177-2  
Data Sheet  
ADC Mode and Interface Mode Configuration  
Gain Registers  
The ADC mode register and the interface mode register configure  
the core peripherals for use by the AD7177-2 and the mode for  
the digital interface.  
The gain registers are 24-bit registers that hold the gain  
calibration coefficient for the ADC. The gain registers are  
read/write registers. These registers are configured at power-on  
with factory calibrated coefficients. Therefore, every device has  
different default coefficients. The default value is automatically  
overwritten if a system full-scale calibration is initiated by the  
user or if the gain register is written to by the user. For more  
information on calibration, see the Operating Modes section.  
ADC Mode Register  
The ADC mode register primarily sets the conversion mode of  
the ADC to either continuous or single conversion. The user  
can also select the standby and power-down modes, as well as  
any of the calibration modes. In addition, this register contains  
the clock source select bits and the internal reference enable bits.  
The reference select bits are contained in the setup configuration  
registers (see the ADC Setups section for more information).  
Offset Registers  
The offset registers hold the offset calibration coefficient for the  
ADC. The power-on reset value of the offset registers is 0x800000.  
The offset registers are 24-bit read/write registers. The power-  
on reset value is automatically overwritten if an internal or  
system zero-scale calibration is initiated by the user or if the offset  
registers are written to by the user.  
Interface Mode Register  
The interface mode register configures the digital interface  
operation. This register allows the user to control data-word  
length, CRC enable, data + status read, and continuous read mode.  
The details of the ADC mode and interface mode registers are  
shown in Table 15 and Table 16, respectively. For more information,  
see the Digital Interface section.  
Table 15. ADC Mode Register  
Reg. Name  
0x01 ADCMODE [15:8] REF_EN  
[7:0] Reserved  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Reserved  
Bit 2  
CLOCKSEL  
Bit 1  
Delay  
Reserved  
Bit 0  
Reset  
RW  
HIDE_DELAY SING_CYC  
Mode  
0x8000 RW  
Table 16. Interface Mode Register  
Reg. Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Reserved  
CRC_EN WL32  
Bit 1  
Bit 0  
Reset  
0x0000  
RW  
0x02 IFMODE [15:8]  
[7:0]  
Reserved  
ALT_SYNC  
Reserved  
IOSTRENGTH  
DOUT_RESET  
Reserved  
RW  
CONTREAD  
DATA_STAT  
REG_CHECK  
Rev. B | Page 24 of 60  
 
 
Data Sheet  
AD7177-2  
Understanding Configuration Flexibility  
Programming the gain and offset registers is optional for any  
use case, as indicated by the dashed lines between the register  
blocks.  
The most straightforward implementation of the AD7177-2 is  
to use two differential inputs with adjacent analog inputs and  
run both of them with the same setup, gain correction, and  
offset correction register. In this case, the user selects the  
following differential inputs: AIN0/AIN1 and AIN2/AIN3. In  
Figure 46, the registers shown in black font must be pro-  
grammed for such a configuration. The registers shown in gray  
font are redundant in this configuration.  
An alternative way to implement these two fully differential  
inputs is by taking advantage of the four available setups.  
Motivation for doing this includes having a different speed/noise  
requirement on each of the differential inputs, or there may be a  
specific offset or gain correction for each channel. Figure 47  
shows how each of the differential inputs can use a separate  
setup, allowing full flexibility in the configuration of each channel.  
CHANNEL  
REGISTERS  
SETUP CONFIG  
REGISTERS  
FILTER CONFIG  
REGISTERS  
GAIN REGISTERS*  
OFFSET REGISTERS  
AIN0  
AIN1  
AIN2  
AIN3  
AIN4  
CH0  
SETUPCON0  
FILTCON0  
GAIN0  
0x38  
OFFSET0  
0x30  
0x10  
0x20  
0x28  
0x29  
0x2A  
0x2B  
CH1  
CH2  
CH3  
SETUPCON1  
SETUPCON2  
SETUPCON3  
FILTCON1  
FILTCON2  
FILTCON3  
GAIN1  
GAIN2  
GAIN3  
OFFSET1  
0x31  
0x21  
0x22  
0x23  
0x39  
0x3A  
0x3B  
0x11  
0x12  
0x13  
OFFSET2  
0x32  
OFFSET3  
0x33  
SELECT ANALOG INPUT PAIRS  
ENABLE THE CHANNEL  
SELECT SETUP 0  
SELECT PERIPHERAL  
FUNCTIONS FOR  
ADC CHANNEL  
SELECT DIGITAL  
FILTER TYPE  
AND OUTPUT DATA RATE  
GAIN CORRECTION  
OPTIONALLY  
PROGRAMMED  
OFFSET CORRECTION  
OPTIONALLY PROGRAMMED  
PER SETUP AS REQUIRED  
PER SETUP AS REQUIRED  
(*FACTORY CALIBRATED)  
DATA OUTPUT CODING  
REFERENCE SOURCE  
INPUT BUFFERS  
SINC5 + SINC1  
SINC3  
SINC3 MAP  
ENHANCED 50Hz AND 60Hz  
Figure 46. Two Fully Differential Inputs, Both Using a Single Setup (SETUPCON0; FILTCON0; GAIN0; OFFSET0)  
CHANNEL  
REGISTERS  
SETUP CONFIG  
REGISTERS  
FILTER CONFIG  
REGISTERS  
GAIN REGISTERS*  
OFFSET REGISTERS  
AIN0  
AIN1  
AIN2  
AIN3  
AIN4  
CH0  
SETUPCON0  
FILTCON0  
0x28  
GAIN0  
0x38  
OFFSET0  
0x30  
0x10  
0x20  
CH1  
CH2  
CH3  
SETUPCON1  
SETUPCON2  
SETUPCON3  
FILTCON1  
FILTCON2  
FILTCON3  
GAIN1  
GAIN2  
GAIN3  
OFFSET1  
0x31  
0x21  
0x22  
0x23  
0x29  
0x2A  
0x2B  
0x39  
0x3A  
0x3B  
0x11  
0x12  
0x13  
OFFSET2  
0x32  
OFFSET3  
0x33  
SELECT PERIPHERAL  
FUNCTIONS FOR  
ADC CHANNEL  
SELECT DIGITAL  
FILTER TYPE  
AND OUTPUT DATA RATE  
GAIN CORRECTION  
OPTIONALLY  
PROGRAMMED  
OFFSET CORRECTION  
OPTIONALLY PROGRAMMED  
PER SETUP AS REQUIRED  
PER SETUP AS REQUIRED  
(*FACTORY CALIBRATED)  
DATA OUTPUT CODING  
REFERENCE SOURCE  
INPUT BUFFERS  
SINC5 + SINC1  
SINC3  
SINC3 MAP  
ENHANCED 50Hz AND 60Hz  
Figure 47. Two Fully Differential Inputs with a Setup per Channel  
Rev. B | Page 25 of 60  
 
 
AD7177-2  
Data Sheet  
Figure 48 shows an example of how the channel registers span  
between the analog input pins and the setup configurations  
downstream. In this example, one differential input and two single-  
ended inputs are required. The single-ended inputs are the  
AIN2/AIN4 and AIN3/AIN4 combinations. The differential input  
pair is AIN0/AIN1and uses Setup 0. The two single-ended input  
pairs are set up as diagnostics; therefore, use a separate setup  
from the differential input but share a setup between them,  
Setup 1. Given that two setups are selected for use, the  
programmed as required. Optional gain and offset correction  
can be employed on a per setup basis by programming the  
GAIN0 and GAIN1 registers and the OFFSET0 and OFFSET1  
registers.  
In the example shown in Figure 48, the CH0 to CH2 registers  
are used. Setting the MSB in each of these registers, the CH_EN0  
to CH_EN2 bits, enables the three combinations via the crosspoint  
mux. When the AD7177-2 converts, the sequencer transitions  
in ascending sequential order from CH0 to CH1 to CH2 before  
looping back to CH0 to repeat the sequence.  
SETUPCON0 and SETUPCON1 registers are programmed as  
required, and the FILTCON0 and FILTCON1 registers are also  
CHANNEL  
REGISTERS  
SETUP CONFIG  
REGISTERS  
FILTER CONFIG  
REGISTERS  
GAIN REGISTERS*  
OFFSET REGISTERS  
AIN0  
AIN1  
AIN2  
AIN3  
AIN4  
CH0  
SETUPCON0  
FILTCON0  
GAIN0  
0x38  
OFFSET0  
0x30  
0x10  
0x20  
0x28  
0x29  
0x2A  
0x2B  
CH1  
CH2  
CH3  
SETUPCON1  
SETUPCON2  
SETUPCON3  
FILTCON1  
FILTCON2  
FILTCON3  
GAIN1  
GAIN2  
GAIN3  
OFFSET1  
0x31  
0x21  
0x22  
0x23  
0x39  
0x3A  
0x3B  
0x11  
0x12  
0x13  
OFFSET2  
0x32  
OFFSET3  
0x33  
SELECT ANALOG INPUT PARTS  
ENABLE THE CHANNEL  
SELECT SETUP  
SELECT PERIPHERAL  
FUNCTIONS FOR  
ADC CHANNEL  
SELECT DIGITAL  
FILTER TYPE  
AND OUTPUT DATA RATE  
GAIN CORRECTION  
OPTIONALLY  
PROGRAMMED  
OFFSET CORRECTION  
OPTIONALLY PROGRAMMED  
PER SETUP AS REQUIRED  
PER SETUP AS REQUIRED  
(*FACTORY CALIBRATED)  
DATA OUTPUT CODING  
REFERENCE SOURCE  
INPUT BUFFERS  
SINC5 + SINC1  
SINC3  
SINC3 MAP  
ENHANCED 50Hz AND 60Hz  
Figure 48. Mixed Differential and Single-Ended Configuration Using Multiple Shared Setups  
Rev. B | Page 26 of 60  
 
Data Sheet  
AD7177-2  
CIRCUIT DESCRIPTION  
AVDD1  
BUFFERED ANALOG INPUT  
AIN0  
AIN1  
The AD7177-2 has true rail-to-rail, integrated, precision unity-  
gain buffers on both ADC analog inputs. The buffers provide  
the benefit of giving the user high input impedance with only  
30 nA typical input current, allowing high impedance sources  
to be connected directly to the analog inputs. The buffers fully  
drive the internal ADC switch capacitor sampling network,  
simplifying the analog front-end circuit requirements while  
consuming a very efficient 2.9 mA typical per buffer. Each analog  
input buffer amplifier is fully chopped, meaning that it minimizes  
the offset error drift and 1/f noise of the buffer. The 1/f noise  
profile of the ADC and buffer combined is shown in Figure 49.  
0
AVSS  
AVDD1  
Ø1  
+IN  
CS1  
CS2  
AVSS  
Ø2  
Ø2  
AVDD1  
AIN2  
AVSS  
–IN  
AVDD1  
Ø1  
AIN3  
AIN4  
–20  
–40  
AVSS  
AVDD1  
–60  
–80  
AVSS  
–100  
–120  
–140  
–160  
–180  
–200  
Figure 50. Simplified Analog Input Circuit  
The CS1 and CS2 capacitors each have a magnitude in the order  
of a number of picofarads. This capacitance is the combination  
of both the sampling capacitance and the parasitic capacitance.  
Fully Differential Inputs  
Because the AIN0 to AIN4 analog inputs are connected to a  
crosspoint multiplexer, any combination of signals can be used  
to create an analog input pair. The crosspoint multiplexer allows  
the user to select two fully differential inputs or four single-  
ended inputs.  
1
10  
100  
1000  
FREQUENCY (Hz)  
Figure 49. Shorted Input FFT (Analog Input Buffers Enabled)  
The analog input buffers do not suffer from linearity  
degradation when operating at the rails, unlike many discrete  
amplifiers. When operating at or close to the AVDD1 and AVSS  
supply rails, there is an increase in input current. This increase  
is most notable at higher temperatures. Figure 38 and Figure 39  
show the analog input current for various conditions. With the  
analog input buffers disabled, the average input current to the  
AD7177-2 changes linearly with the differential input voltage at  
a rate of 48 µA /V.  
If two fully differential input paths are connected to the AD7177-2,  
using AIN0/AIN1 as one differential input pair and AIN2/AIN3  
as the second differential input pair is recommended. This is  
due to the relative locations of these pins to each other. Decouple all  
analog inputs to AVSS.  
Single-Ended Inputs  
The user can also choose to measure four different single-ended  
analog inputs. In this case, each of the analog inputs is converted  
as the difference between the single-ended input to be meas-  
ured and a set analog input common pin. Because there is a  
crosspoint multiplexer, the user can set any of the analog inputs  
as the common pin. An example of such a scenario is to connect  
the AIN4 pin to AVSS or to the REFOUT voltage (that is, AVSS  
+ 2.5 V) and select this input when configuring the crosspoint  
multiplexer. When using the AD7177-2 with single-ended  
inputs, the INL specification is degraded.  
CROSSPOINT MULTIPLEXER  
There are five analog input pins: AIN0, AIN1, AIN2, AIN3, and  
AIN4. Each of these pins connects to the internal crosspoint  
multiplexer. The crosspoint multiplexer enables any of these inputs  
to be configured as an input pair, either single-ended or fully  
differential. The AD7177-2 can have up to four active channels.  
When more than one channel is enabled, the channels are  
automatically sequenced in order from the lowest enabled channel  
number to the highest enabled channel number. The output of  
the multiplexer is connected to the input of the integrated true  
rail-to-rail buffers. These can be bypassed and the multiplexer  
output can be directly connected to the switched-capacitor input  
of the ADC. The simplified analog input circuit is shown in  
Figure 50.  
Rev. B | Page 27 of 60  
 
 
 
 
 
AD7177-2  
Data Sheet  
AD7177-2, the internal reference is enabled by default and is  
output on the REFOUT pin. When an external reference is used  
instead of the internal reference to supply the AD7177-2,  
attention must be paid to the output of the REFOUT pin. If the  
internal reference is not being used elsewhere in the application,  
ensure that the REFOUT pin is not hardwired to AVSS because  
this draws a large current on power-up. On power-up, if the  
internal reference is not being used, write to the ADC mode  
register, disabling the internal reference. This is controlled by  
the REF_EN bit (Bit 15) in the ADC mode register, which is  
shown in Table 18.  
AD7177-2 REFERENCE  
The AD7177-2 offers the user the option of either supplying an  
external reference to the REF+ and REF− pins of the device or  
allowing the use of the internal 2.5 V, low noise, low drift reference.  
Select the reference source to be used by the analog input by setting  
the REF_SELx bits (Bits[5:4]) in the setup configuration registers  
appropriately. The structure of the Setup Configuration 0 register  
is shown in Table 17. The AD7177-2 defaults on power-up to  
use the internal 2.5 V reference.  
External Reference  
The AD7177-2 has a fully differential reference input applied  
through the REF+ and REF− pins. Standard low noise, low driꢀ  
voltage references, such as the ADR445, ADR444, and ADR441,  
are recommended for use. Apply the external reference to the  
AD7177-2 reference pins as shown in Figure 51. Decouple the  
output of any external reference to AVSS. As shown in Figure 51,  
the ADR445 output is decoupled with a 0.1 μF capacitor at its  
output for stability purposes. The output is then connected to a  
4.7 μF capacitor, which acts as a reservoir for any dynamic  
charge required by the ADC, and followed by a 0.1 μF  
Internal Reference  
The AD7177-2 includes its own low noise, low drift voltage  
reference. The internal reference has a 2.5 V output. The internal  
reference is output on the REFOUT pin after the REF_EN bit in  
the ADC mode register is set and is decoupled to AVSS with a  
0.1 μF capacitor. The AD7177-2 internal reference is enabled by  
default on power-up and is selected as the reference source for  
the ADC. When using the internal reference, the INL performance  
is degraded as shown in Figure 19.  
The REFOUT signal is buffered before being output to the pin.  
The signal can be used externally in the circuit as a common-mode  
source for external amplifier configurations.  
decoupling capacitor at the REF+ input. This capacitor is placed  
as close as possible to the REF+ and REF− pins. e REF− pin  
is connected directly to the AVSS potential. On power-up of the  
AD7177-2  
5.5V TO 18V  
ADR4452  
3
2
REF+  
REF–  
0.1µF  
1
5V VREF  
1
0.1µF  
4.7µF  
0.1µF  
1
1
1
1
2
ALL DECOUPLING IS TO AVSS.  
ANY OF THE ADR440/ADR441/ADR443/ADR444/ADR445 FAMILY OF REFERENCES  
CAN BE USED. THE ADR444 AND ADR441 BOTH ENABLE REUSE OF THE  
5V ANALOG SUPPLY NEEDED FOR AVDD1 TO POWER THE REFERENCE V  
.
IN  
Figure 51. External Reference ADR445 Connected to the AD7177-2 Reference Pins  
Table 17. Setup Configuration 0 Register  
Reg. Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
BI_UNIPOLAR0 REFBUF0+ REFBUF0− AINBUF0+  
REF_SEL0 Reserved  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reset RW  
0x20 SETUPCON0 [15:8]  
[7:0]  
Reserved  
AINBUF0−  
0x1320 RW  
BURNOUT_EN0 Reserved  
Table 18. ADC Mode Register  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
CLOCKSEL  
Bit 1  
Delay  
Reserved  
Bit 0  
Reset  
0x8000  
RW  
0x01  
ADCMODE [15:8]  
[7:0]  
REF_EN  
Reserved  
HIDE_DELAY  
SING_CYC  
Mode  
Reserved  
RW  
Rev. B | Page 28 of 60  
 
 
 
 
Data Sheet  
AD7177-2  
further exaggerated if the IOSTRENGTH bit is set at higher  
IOVDD levels (see Table 28 for more information).  
BUFFERED REFERENCE INPUT  
The AD7177-2 has true rail-to-rail, integrated, precision unity-  
gain buffers on both ADC reference inputs. The buffers provide  
the benefit of giving the user high input impedance and allow  
high impedance external sources to be directly connected to the  
reference inputs. The integrated reference buffers can fully drive  
the internal reference switch capacitor sampling network,  
simplifying the reference circuit requirements while consuming  
a very efficient 2.9 mA typical per buffer. Each reference input  
buffer amplifier is fully chopped, meaning that it minimizes the  
offset error drift and 1/f noise of the buffer. When using an  
external reference, such as the ADR445, ADR444, and ADR441,  
these buffers are not required because these references, with  
proper decoupling, can drive the reference inputs directly.  
External Crystal  
If higher precision, lower jitter clock sources are required, the  
AD7177-2 can use an external crystal to generate the master  
clock. The crystal is connected to the XTAL1 and XTAL2/CLKIO  
pins. A recommended crystal for use is the FA-20H, a 16 MHz,  
10 ppm, 9 pF crystal from Epson-Toyocom, that is available in a  
surface-mount package. As shown in Figure 52, insert two  
capacitors from the traces connecting the crystal to the XTAL1  
and XTAL2/CLKIO pins. These capacitors allow circuit tuning.  
Connect these capacitors to the DGND pin. The value for these  
capacitors depends on the length and capacitance of the trace  
connections between the crystal and the XTAL1 and XTAL2/  
CLKIO pins. Therefore, the values of these capacitors differ  
depending on the printed circuit board (PCB) layout and the  
crystal employed.  
CLOCK SOURCE  
The AD7177-2 uses a nominal master clock of 16 MHz. The  
AD7177-2 can source its sampling clock from one of three  
sources:  
AD7177-2  
Cx1  
*
Internal oscillator  
External crystal  
External clock source  
9
XTAL1  
XTAL2/CLKIO 10  
Cx2  
All output data rates listed in this data sheet relate to a master  
clock rate of 16 MHz. Using a lower clock frequency from, for  
instance, an external source scales any listed data rate proportion-  
ally. To achieve the specified data rates, particularly rates for the  
rejection of 50 Hz and 60 Hz, use a 16 MHz clock. The source  
of the master clock is selected by setting the CLOCKSEL bits  
(Bits[3:2]) in the ADC mode register as shown in Table 18. The  
default operation on power-up and reset of the AD7177-2 is to  
operate with the internal oscillator. It is possible to fine tune the  
output data rate and filter notch at low output data rates using  
the SINC3_MAPx bit. See the Sinc3 Filter section for more  
information.  
*
*DECOUPLE TO DGND.  
Figure 52. External Crystal Connections  
The external crystal circuitry can be sensitive to the SCLK  
edges, depending on SCLK frequency, IOVDD voltage, crystal  
circuitry layout, and the crystal used. During crystal startup, any  
disturbances caused by the SLCK edges may cause double edges  
on the crystal input, resulting in invalid conversions until the  
crystal voltage has reached a high enough level such that any  
interference from the SCLK edges is insufficient to cause double  
clocking. This double clocking can be avoided by ensuring that  
the crystal circuitry has reached a sufficient voltage level after  
startup before applying any SCLK signal.  
Internal Oscillator  
The internal oscillator runs at 16 MHz and can be used as the  
ADC master clock. It is the default clock source for the AD7177-2  
and is specified with an accuracy of 2.5%.  
Due to the nature of the crystal circuitry, it is recommended  
that empirical testing of the circuit be performed under the  
required conditions, with the final PCB layout and crystal, to  
ensure correct operation.  
There is an option to allow the internal clock oscillator to be  
output on the XTAL2/CLKIO pin. The clock output is driven to  
the IOVDD logic level. Use of this option can affect the dc  
performance of the AD7177-2 due to the disturbance intro-  
duced by the output driver. The extent to which the performance  
is affected depends on the IOVDD voltage supply. Higher  
IOVDD voltages create a wider logic output swing from the  
driver and affect performance to a greater extent. This effect is  
External Clock  
The AD7177-2 can also use an externally supplied clock. In  
systems where this is desirable, the external clock is routed to  
the XTAL2/CLKIO pin. In this configuration, the XTAL2/CLKIO  
pin accepts the externally sourced clock and routes it to the  
modulator. The logic level of this clock input is defined by the  
voltage applied to the IOVDD pin.  
Rev. B | Page 29 of 60  
 
 
 
AD7177-2  
Data Sheet  
DIGITAL FILTERS  
The AD7177-2 has three flexible filter options to allow optimiza-  
tion of noise, settling time, and rejection, as follows:  
SINC3 FILTER  
The sinc3 filter achieves the best single-channel noise performance  
at lower rates and is, therefore, most suitable for single-channel  
applications. The sinc3 filter always has a settling time, tSETTLE  
Sinc5 + sinc1 filter  
Sinc3 filter  
Enhanced 50 Hz and 60 Hz rejection filters  
,
equal to  
tSETTLE = 3/Output Data Rate  
50Hz AND 60Hz  
POSTFILTER  
Figure 55 shows the frequency domain filter response for the  
sinc3 filter. The sinc3 filter has good roll-off over frequency and  
has wide notches for good notch frequency rejection.  
SINC1  
SINC5  
SINC3  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
Figure 53. Digital Filter Block Diagram  
The filter and output data rate are configured by setting the  
appropriate bits in the filter configuration register for the  
selected setup. Each channel can use a different setup and,  
therefore, a different filter and output data rate. See the Register  
Details section for more information.  
SINC5 + SINC1 FILTER  
The sinc5 + sinc1 filter is targeted at multiplexed applications  
and achieves single cycle settling at output data rates of 10 kSPS and  
lower. The sinc5 block output is fixed at the maximum rate of  
10 kSPS, and the sinc1 block output data rate can be varied to  
control the final ADC output data rate. Figure 54 shows the  
frequency domain response of the sinc5 + sinc1 filter at a 50 SPS  
ODR. The sinc5 + sinc1 filter has a slow roll-off over frequency and  
narrow notches.  
–120  
0
50  
100  
FREQUENCY (Hz)  
150  
Figure 55. Sinc3 Filter Response  
The ODR with the accompanying settling time and rms noise  
for the sinc3 filter are shown in Table 21 and Table 22. It is possible  
to finely tune the output data rate for the sinc3 filter by setting the  
SINC3_MAPx bits in the filter configuration registers. If this bit is  
set, the mapping of the filter register changes to directly program  
the decimation rate of the sinc3 filter. All other options are  
eliminated. The data rate when on a single channel can be  
calculated using the following equation:  
0
–20  
–40  
–60  
fMOD  
Output Data Rate =  
32 × FILTCONx[14:0]  
–80  
where:  
–100  
–120  
fMOD is the modulator rate (MCLK/2) and is 8 MHz for a  
16 MHz MCLK.  
FILTCONx[14:0] are the contents on the filter configuration  
registers excluding the MSB.  
0
50  
100  
FREQUENCY (Hz)  
150  
Figure 54. Sinc5 + Sinc1 Filter Response at 50 SPS ODR  
For example, an output data rate of 50 SPS can be achieved with  
SINC3_MAPx enabled by setting the FILTCONx[14:0] bits to a  
value of 5000.  
The ODR with the accompanying settling time and rms noise  
for the sinc5 + sinc1 filter are shown in Table 19 and Table 20.  
Rev. B | Page 30 of 60  
 
 
 
 
 
Data Sheet  
AD7177-2  
Figure 57 shows the same step on the analog input but with  
single cycle settling enabled. The analog input requires at least a  
single cycle for the output to be fully settled. The output data  
SINGLE CYCLE SETTLING  
The AD7177-2 can be configured by setting the SING_CYC bit  
in the ADC mode register so that only fully settled data is output,  
effectively putting the ADC into a single cycle settling mode. This  
mode achieves single cycle settling by reducing the output data  
rate to be equal to the settling time of the ADC for the selected  
output data rate. This bit has no effect with the sinc5 + sinc1  
filter at output data rates of 10 kSPS and lower.  
RDY  
rate, as indicated by the  
signal, is reduced to equal the  
settling time of the filter at the selected output data rate.  
ANALOG  
INPUT  
FULLY  
SETTLED  
ADC  
OUTPUT  
Figure 56 shows a step on the analog input with this mode  
disabled and the sinc3 filter selected. The analog input requires  
at least three cycles after the step change for the output to reach  
the final settled value.  
tSETTLE  
Figure 57. Step Input with Single Cycle Settling  
ANALOG  
INPUT  
FULLY  
SETTLED  
ADC  
OUTPUT  
1/ODR  
Figure 56. Step Input Without Single Cycle Settling  
Table 19. Output Data Rate, Settling Time, and Noise Using the Sinc5 + Sinc1 Filter with Input Buffers Disabled  
Output Data Rate  
(SPS/Channel);  
SING_CYC = 1 or  
with Multiple  
Channels  
Default Output  
Data Rate (SPS);  
SING_CYC = 0  
and Single  
Effective  
Resolution  
with 5 V  
Reference  
(Bits)  
Dynamic  
Range with  
5 V  
Reference  
(dB)  
Peak-to-Peak  
Resolution  
with 5 V  
Reference  
(Bits)  
Notch  
Frequency  
(Hz)  
Settling  
Time1  
Channel  
Noise  
(µV rms)  
Noise  
Enabled1  
Enabled1  
(µV p-p)2  
10,000  
5000  
2500  
1000  
500  
397.5  
200  
100  
59.92  
49.96  
20  
16.66  
10  
10,000  
5000  
2500  
1000  
500.0  
397.5  
200.0  
100  
59.92  
49.96  
20.00  
16.66  
10.00  
5.00  
100 µs  
200 µs  
400 µs  
1.0 ms  
2.0 ms  
2.516 ms  
5.0 ms  
11,905  
5435  
2604  
1016  
504  
400.00  
200.64  
100.16  
59.98  
50.00  
20.01  
16.66  
10.00  
5.00  
2.5  
1.7  
1.2  
21.9  
22.5  
23  
23.6  
24.3  
24.4  
25  
25.6  
25.8  
26  
26.7  
26.7  
26.8  
27.3  
123  
18.3  
12  
8.2  
5.2  
3.2  
3
19.1  
19.7  
20.2  
20.9  
21.6  
21.7  
22.3  
22.9  
23.1  
23.3  
24  
126.4  
129.4  
133.2  
135.9  
137  
139.8  
143  
145.4  
145.9  
150.1  
151  
0.77  
0.57  
0.5  
0.36  
0.25  
0.19  
0.18  
0.11  
0.1  
2
10 ms  
1.3  
1.1  
0.95  
0.6  
0.45  
0.4  
0.34  
16.67 ms  
20.016 ms  
50.0 ms  
60.02 ms  
100 ms  
200 ms  
24.1  
24.2  
24.6  
0.08  
0.07  
152.9  
154.1  
5
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.  
2 Measurement taken using 1000 samples.  
Rev. B | Page 31 of 60  
 
 
 
 
AD7177-2  
Data Sheet  
Table 20. Output Data Rate, Settling Time, and Noise Using the Sinc5 + Sinc1 Filter with Input Buffers Enabled  
Default  
Output Data  
Output Data Rate  
(SPS/Channel);  
SING_CYC = 1 or  
with Multiple  
Rate (SPS);  
SING_CYC = 0  
and Single  
Channel  
Effective  
Resolution  
Noise with 5 V  
Dynamic  
Range  
with 5 V  
Reference  
(dB)  
Peak-to-Peak  
Resolution with  
5 V Reference  
Notch  
Frequency  
(Hz)  
Settling  
Time1  
(µV  
rms)  
Reference  
(Bits)  
Noise  
Enabled1  
Channels Enabled1  
(µV p-p)2 (Bits)  
10,000  
5000  
2500  
1000  
500  
10,000  
5000  
2500  
1000  
500.0  
397.5  
100 µs  
200 µs  
400 µs  
1.0 ms  
2.0 ms  
2.516  
ms  
5.0 ms  
10 ms  
11,905  
5435  
2604  
1016  
504  
3
21.7  
22.2  
22.7  
23.4  
23.8  
121.4  
124.5  
127.4  
131.7  
134.3  
23  
16  
10  
5.7  
3.9  
3.7  
18.7  
19.3  
19.9  
20.7  
21.3  
2.1  
1.5  
0.92  
0.68  
0.6  
397.5  
400.00  
24.1  
135.4  
21.4  
22.1  
22.5  
200  
100  
59.92  
200.0  
100  
59.92  
200.64  
100.16  
59.98  
0.43  
0.32  
0.23  
24.8  
25.2  
138.3  
140.9  
2.2  
1.7  
1.2  
16.67  
ms  
25.7  
143.7  
23  
49.96  
49.96  
20.016  
ms  
50.0 ms  
60.02  
ms  
100 ms  
200 ms  
50.00  
0.2  
1
26  
144.9  
148  
23.3  
23.7  
20  
16.66  
20.00  
16.66  
20.01  
16.66  
0.14  
0.13  
26.4  
26.6  
0.75  
0.66  
148.7  
23.9  
24.1  
24.6  
10  
5
10.00  
5.00  
10.00  
5.00  
0.1  
0.07  
26.7  
26.7  
151  
154.1  
0.47  
0.32  
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.  
2 Measurement taken using 1000 samples.  
Table 21. Output Data Rate, Settling Time, and Noise Using the Sinc3 Filter with Input Buffers Disabled  
Output Data Rate  
(SPS/Channel);  
SING_CYC = 1 or  
with Multiple  
Default Output  
Data Rate (SPS);  
SING_CYC = 0 and  
Single Channel  
Enabled1  
Dynamic  
Range  
Peak-to-Peak  
Resolution  
with 5 V  
Reference  
(Bits)  
Notch  
Fre-  
quency  
(Hz)  
Effective  
Noise Resolution with with 5 V  
Settling  
Time1  
(µV  
rms)  
5 V Reference  
(Bits)  
Reference Noise  
(dB)  
Channels Enabled1  
(µV p--p)2  
10,000  
5000  
2500  
1000  
500  
400  
200  
100  
60  
50  
20  
16.67  
10  
5
3333  
1667  
833  
333.3  
166.7  
133.3  
66.7  
33.33  
19.99  
16.67  
6.67  
300 µs  
6 µs  
1.2 ms  
3 ms  
10,000  
5000  
2500  
1000  
500  
400  
200  
100  
59.98  
50  
1.8  
1.3  
22.4  
22.9  
23.4  
24  
24.6  
24.8  
25.5  
26  
26.3  
26.5  
26.9  
27  
27.1  
27.5  
125.9  
128.7  
131.8  
136  
138.1  
138.9  
143  
144.9  
148.7  
148.7  
152.9  
154.1  
155.4  
157  
14  
9.5  
6
19.4  
20  
0.91  
0.56  
0.44  
0.4  
0.25  
0.2  
0.13  
0.13  
0.08  
0.07  
0.06  
0.05  
20.7  
21.3  
21.9  
22.1  
22.8  
23.3  
23.6  
23.8  
24.2  
24.3  
24.4  
24.8  
3.9  
2.5  
2.3  
1.4  
1
0.8  
0.7  
0.42  
0.37  
0.28  
0.21  
6 ms  
7.5 ms  
15 ms  
30 ms  
50.02 ms  
60 ms  
150 ms  
180 ms  
300 ms  
600 ms  
20  
16.67  
10  
5.56  
3.33  
1.67  
5
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.  
2 Measurement taken using 1000 samples.  
Rev. B | Page 32 of 60  
 
 
 
Data Sheet  
AD7177-2  
Table 22. Output Data Rate, Settling Time, and Noise Using the Sinc3 Filter with Input Buffers Enabled  
Output Data Rate  
(SPS/Channel);  
SING_CYC = 1 or  
with Multiple  
Default Output  
Data Rate (SPS);  
SING_CYC = 0 and  
Single Channel  
Enabled1  
Effective  
Resolution  
with 5 V  
Reference  
(Bits)  
Dynamic  
Range  
with 5 V  
Reference  
(dB)  
Peak-to-Peak  
Resolution  
with 5 V  
Reference  
(Bits)  
Notch  
Frequency  
(Hz)  
Settling  
Time1  
Noise  
(µV rms)  
Noise  
Channels Enabled1  
(µV p-p)2  
10,000  
5000  
2500  
1000  
500  
400  
200  
100  
60  
50  
20  
16.67  
10  
5
3333  
1667  
833  
333.3  
166.7  
133.3  
66.7  
33.33  
19.99  
16.67  
6.67  
300 µs  
6 µs  
1.2 ms  
3 ms  
10,000  
5000  
2500  
1000  
500  
400  
200  
100  
59.98  
50  
2.1  
1.5  
1.1  
22.2  
22.7  
23.1  
23.7  
24.4  
24.5  
25.1  
25.7  
25.8  
26.2  
26.7  
26.8  
26.9  
27.2  
124.5  
127.4  
130.1  
133.9  
136.6  
138.7  
140.9  
144.9  
146.4  
147.4  
148.7  
149.4  
151  
16  
11  
7
4.5  
3
2.7  
1.8  
1.2  
1.1  
0.83  
0.61  
0.6  
0.55  
0.35  
19.3  
19.8  
20.4  
21.1  
21.7  
21.8  
22.4  
23  
23.1  
23.5  
24  
24.1  
24.2  
24.5  
0.71  
0.52  
0.41  
0.32  
0.2  
0.17  
0.15  
0.13  
0.12  
0.1  
6 ms  
7.5 ms  
15 ms  
30 ms  
50.02 ms  
60 ms  
150 ms  
180 ms  
300 ms  
600 ms  
20  
16.67  
10  
5.56  
3.33  
1.67  
5
0.08  
152.9  
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.  
2 Measurement taken using 1000 samples.  
Rev. B | Page 33 of 60  
 
 
AD7177-2  
Data Sheet  
sinc1 filter must be selected when using the enhanced filters to  
achieve the specified settling time and noise performance. Table 23  
shows the output data rates with the accompanying settling  
time, rejection, and rms noise. Figure 58 to Figure 65 show the  
frequency domain plots of the responses from the enhanced filters.  
ENHANCED 50 HZ AND 60 HZ REJECTION FILTERS  
The enhanced filters are designed to provide rejection of 50 Hz  
and 60 Hz simultaneously and to allow the user to trade off  
settling time and rejection. These filters can operate up to  
27.27 SPS or can reject up to 90 dB of 50 Hz 1 Hz and 60 Hz  
1 Hz interference. These filters are realized by postfiltering  
the output of the sinc5 + sinc1 filter. For this reason, the sinc5 +  
Table 23. Enhanced Filters Output Data Rate, Noise, Settling Time, and Rejection Using the Enhanced Filters  
Settling  
Time  
Output Data Rate (SPS) (ms)  
Simultaneous Rejection of 50 Hz  
1 Hz and 60 Hz 1 Hz (dB)1  
Noise Peak-to-Peak  
(µV rms) Resolution (Bits)  
Comments  
Input Buffers Disabled  
27.27  
25  
20  
16.667  
36.67  
40.0  
50.0  
60.0  
47  
62  
85  
90  
0.22  
0.2  
0.2  
22.7  
22.9  
22.9  
23  
See Figure 58 and Figure 61  
See Figure 59 and Figure 62  
See Figure 60 and Figure 63  
See Figure 64 and Figure 65  
0.17  
Input Buffers Enabled  
27.27  
25  
20  
36.67  
40.0  
50.0  
60.0  
47  
62  
85  
90  
0.22  
0.22  
0.21  
0.21  
22.7  
22.7  
22.8  
22.8  
See Figure 58 and Figure 61  
See Figure 59 and Figure 62  
See Figure 60 and Figure 63  
See Figure 64 and Figure 65  
16.667  
1 Master clock = 16.00 MHz.  
Rev. B | Page 34 of 60  
 
 
Data Sheet  
AD7177-2  
0
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–100  
0
0
0
100  
200  
300  
400  
500  
600  
600  
600  
40  
45  
50  
55  
60  
65  
70  
FREQUENCY (Hz)  
FREQUENCY (Hz)  
Figure 58. 27.27 SPS ODR, 36.67 ms Settling Time  
Figure 61. 27.27 SPS ODR, 36.67 ms Settling Time at 50 Hz/60 Hz  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–100  
100  
200  
300  
400  
500  
40  
45  
50  
55  
60  
65  
70  
FREQUENCY (Hz)  
FREQUENCY (Hz)  
Figure 59. 25 SPS ODR, 40 ms Settling Time  
Figure 62. 25 SPS ODR, 40 ms Settling Time at 50 Hz/60 Hz  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
100  
200  
300  
400  
500  
40  
45  
50  
55  
60  
65  
70  
FREQUENCY (Hz)  
FREQUENCY (Hz)  
Figure 60. 20 SPS ODR, 50 ms Settling Time  
Figure 63. 20 SPS ODR, 50 ms Settling Time at 50 Hz/60 Hz  
Rev. B | Page 35 of 60  
 
 
 
 
 
 
AD7177-2  
Data Sheet  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–100  
0
100  
200  
300  
400  
500  
600  
40  
45  
50  
55  
60  
65  
70  
FREQUENCY (Hz)  
FREQUENCY (Hz)  
Figure 64. 16.667 SPS ODR, 60 ms Settling Time  
Figure 65. 16.667 SPS ODR, 60 ms Settling Time at 50 Hz/60 Hz  
Rev. B | Page 36 of 60  
 
 
 
Data Sheet  
AD7177-2  
OPERATING MODES  
The AD7177-2 has a number of operating modes that can be set  
from the ADC mode register and interface mode register (see  
Table 27 and Table 28). These modes are as follows and are  
described in the following sections:  
register. When the data-word has been read from the data register,  
RDY  
the DOUT/  
pin goes high. The user can read this register  
additional times, if required. However, the user must ensure that  
the data register is not being accessed at the completion of the  
next conversion; otherwise, the new conversion word is lost.  
Continuous conversion mode  
Continuous read mode  
Single conversion mode  
Standby mode  
Power-down mode  
Calibration modes (three modes)  
When several channels are enabled, the ADC automatically  
sequences through the enabled channels, performing one  
conversion on each channel. When all channels have been  
converted, the sequence starts again with the first channel. The  
channels are converted in order from lowest enabled channel to  
highest enabled channel. The data register is updated as soon as  
CONTINUOUS CONVERSION MODE  
RDY  
each conversion is available. The  
output pulses low each  
time a conversion is available. The user can then read the  
conversion while the ADC converts the next enabled channel.  
Continuous conversion is the default power-up mode. The  
RDY  
AD7177-2 converts continuously, and the  
register goes low each time a conversion is complete. If  
RDY  
bit in the status  
CS  
is low,  
output also goes low when a conversion is complete. To  
If the DATA_STAT bit in the interface mode register is set to 1,  
the contents of the status register, along with the conversion data,  
are output each time the data register is read. The status register  
indicates the channel to which the conversion corresponds.  
the  
read a conversion, the user writes to the communications  
register, indicating that the next operation is a read of the data  
CS  
0x44  
0x44  
DIN  
DATA  
DATA  
DOUT/RDY  
SCLK  
Figure 66. Continuous Conversion Mode  
Rev. B | Page 37 of 60  
 
 
AD7177-2  
Data Sheet  
To enable continuous read mode, set the CONTREAD bit in the  
interface mode register. When this bit is set, the only serial interface  
operations possible are reads from the data register. To exit con-  
tinuous read mode, issue a dummy read of the ADC data register  
CONTINUOUS READ MODE  
In continuous read mode, it is not required to write to the  
communications register before reading ADC data; apply only  
RDY  
the required number of SCLK pulses after  
indicate the end of a conversion. When the conversion is read,  
RDY  
goes low to  
RDY  
command (0x44) while the  
output is low. Alternatively, apply  
CS  
a software reset, that is, 64 SCLK pulses with  
= 0 and DIN =  
returns high until the next conversion is available. In this  
1. This resets the ADC and all register contents. These are the  
only commands that the interface recognizes after it is placed in  
continuous read mode. Hold DIN low in continuous read mode  
until an instruction is to be written to the device.  
mode, the data can be read only once. The user must also ensure  
that the data-word is read before the next conversion is  
complete. If the user has not read the conversion before the  
completion of the next conversion or if insufficient serial clocks  
are applied to the AD7177-2 to read the data-word, the serial  
output register is reset shortly before the next conversion is  
complete, and the new conversion is placed in the output serial  
register. The ADC must be configured for continuous  
conversion mode to use continuous read mode.  
If multiple ADC channels are enabled, each channel is output  
in turn, with the status bits being appended to the data if  
DATA_STAT is set in the interface mode register. The status  
register indicates the channel to which the conversion corresponds.  
CS  
0x02  
0x0080  
DIN  
DATA  
DATA  
DATA  
DOUT/RDY  
SCLK  
Figure 67. Continuous Read Mode  
Rev. B | Page 38 of 60  
 
 
Data Sheet  
AD7177-2  
output goes low. The ADC then selects the next channel and  
SINGLE CONVERSION MODE  
begins a conversion. The user can read the present conversion  
while the next conversion is being performed. As soon as the next  
conversion is complete, the data register is updated; therefore,  
the user has a limited period in which to read the conversion.  
When the ADC has performed a single conversion on each of  
the selected channels, it returns to standby mode.  
In single conversion mode, the AD7177-2 performs a single  
conversion and is placed in standby mode after the conversion  
RDY  
is complete. The  
of a conversion. When the data-word has been read from the  
RDY  
output goes low to indicate the completion  
data register, the DOUT/  
pin goes high. The data register  
RDY  
can be read several times, if required, even when the DOUT/  
pin has gone high.  
If the DATA_STAT bit in the interface mode register is set to 1,  
the contents of the status register, along with the conversion, are  
output each time the data register is read. The two LSBs of the  
status register indicate the channel to which the conversion  
corresponds.  
If several channels are enabled, the ADC automatically sequences  
through the enabled channels and performs a conversion on  
RDY  
each channel. When a conversion is started, the DOUT/ pin  
goes high and remains high until a valid conversion is available  
CS  
RDY  
and is low. As soon as the conversion is available, the  
CS  
0x01  
0x8010  
0x44  
DIN  
DATA  
DOUT/RDY  
SCLK  
Figure 68. Single Conversion Mode  
Rev. B | Page 39 of 60  
 
AD7177-2  
Data Sheet  
STANDBY AND POWER-DOWN MODES  
0.75×VIN  
VREF  
Data =  
×223  
(
Offset 0x800000  
)
×
In standby mode, most blocks are powered down. The LDOs  
remain active so that registers maintain their contents. The  
internal reference remains active if enabled, and the crystal  
oscillator remains active if selected. To power down the  
reference in standby mode, set the REF_EN bit in the ADC  
mode register to 0. To power down the clock in standby mode,  
set the CLOCKSEL bits in the ADC mode register to 00  
(internal oscillator).  
Gain  
+ 0x800000  
0x400000  
To start a calibration, write the relevant value to the mode bits  
RDY RDY  
in the ADC mode register. The DOUT/  
pin and the  
bit in the status register go high when the calibration initiates.  
When the calibration is complete, the contents of the correspond-  
ing offset or gain register are updated, the  
register is reset and the  
low), and the AD7177-2 reverts to standby mode.  
RDY  
bit in the status  
output pin returns low (if  
In power-down mode, all blocks are powered down, including  
the LDOs. All registers lose their contents, and the GPIOx  
outputs are placed in three-state. To prevent accidental entry to  
power-down mode, the ADC must first be placed in standby  
mode. Exiting power-down mode requires 64 SCLK pulses with  
RDY  
CS  
is  
During an internal offset calibration, the selected positive  
analog input pin is disconnected, and both modulator inputs  
are connected internally to the selected negative analog input  
pin. For this reason, it is necessary to ensure that the voltage on  
the selected negative analog input pin does not exceed the  
allowed limits and is free from excessive noise and interference.  
CS  
= 0 and DIN = 1, that is, a serial interface reset. A delay of  
500 µs is recommended before issuing a subsequent serial  
interface command to allow the LDO to power up.  
Figure 15 shows the internal reference settling time after  
returning from standby mode (setting REF_EN = 0 and then 1)  
and returning from power-down.  
System calibrations, however, expect the system zero-scale  
(offset) and system full-scale (gain) voltages to be applied to the  
ADC pins before initiating the calibration modes. As a result,  
errors external to the ADC are removed.  
CALIBRATION  
The AD7177-2 allows a two-point calibration to be performed  
to eliminate any offset and gain errors. Three calibration modes  
eliminate these offset and gain errors on a per setup basis, as  
follows:  
From an operational point of view, treat a calibration like  
another ADC conversion. An offset calibration, if required,  
must always be performed before a full-scale calibration. Set the  
RDY  
system software to monitor the  
bit in the status register or  
output to determine the end of a calibration via a  
Internal zero-scale calibration mode  
System zero-scale calibration mode  
System full-scale calibration mode  
RDY  
the  
polling sequence or an interrupt-driven routine. All calibrations  
require a time equal to the settling time of the selected filter and  
output data rate to be completed.  
There is no internal full-scale calibration mode because this is  
calibrated in the factory at the time of production.  
An internal offset calibration, system zero-scale calibration, and  
system full-scale calibration can be performed at any output data  
rate. Using lower output data rates results in better calibration  
accuracy and is accurate for all output data rates. A new offset  
calibration is required for a given channel if the reference source  
for that channel is changed.  
Only one channel can be active during calibration. After each  
conversion, the ADC conversion result is scaled using the ADC  
calibration registers before being written to the data register.  
The default value of the offset register is 0x800000, and the  
nominal value of the gain register is 0x555555. The calibration  
range of the ADC gain is from 0.4 × VREF to 1.05 × VREF. The  
following equations show the calculations that are used for  
24-bit data output. In unipolar mode, the ideal relationship—  
that is, not taking into account the ADC gain error and offset  
error—is as follows:  
The offset error is typically 40 µV and an offset calibration  
reduces the offset error to the order of the noise. The gain error  
is factory calibrated at ambient temperature. Following this  
calibration, the gain error is typically 2.5 ppm of FSR.  
The AD7177-2 provides the user with access to the on-chip  
calibration registers, allowing the microprocessor to read the  
calibration coefficients of the device and to write its own  
calibration coefficients. A read or write of the offset and gain  
registers can be performed at any time except during an internal  
or self calibration.  
0.75×VIN  
VREF  
Gain  
0x400000  
Data =  
×223  
(
Offset 0x800000  
)
×
×2  
In bipolar mode, the ideal relationship—that is, not taking into  
account the ADC gain error and offset error—is as follows:  
Rev. B | Page 40 of 60  
 
 
Data Sheet  
AD7177-2  
DIGITAL INTERFACE  
The programmable functions of the AD7177-2 are controlled via  
the SPI serial interface. The serial interface of the AD7177-2  
For CRC checksum calculations during a write operation, the  
following polynomial is always used:  
CS  
RDY  
x8 + x2 + x + 1  
consists of four signals: , DIN, SCLK, and DOUT/  
. The  
DIN input is used to transfer data into the on-chip registers, and  
the DOUT output is used to access data from the on-chip  
registers. SCLK is the serial clock input for the device, and all data  
transfers (either on the DIN input or on the DOUT output) occur  
with respect to the SCLK signal.  
During read operations, the user can select between this  
polynomial and a simpler exclusive OR (XOR) function. The  
XOR function requires less time to process on the host  
microcontroller than the polynomial-based checksum. The  
CRC_EN bits in the interface mode register enable and disable  
the checksum and allow the user to select between the  
polynomial check and the simple XOR check.  
RDY  
The DOUT/  
the output going low if  
available in the data register. The  
a read operation from the data register is complete. The  
pin also functions as a data ready signal, with  
CS  
is low when a new data-word is  
RDY  
output is reset high when  
RDY  
The checksum is appended to the end of each read and write  
transaction. The checksum calculation for the write transaction  
is calculated using the 8-bit command word and the 8-bit to  
24-bit data. For a read transaction, the checksum is calculated  
using the command word and the 8-bit to 32-bit data output.  
Figure 69 and Figure 70 show SPI write and read transactions,  
respectively.  
output also goes high before updating the data register to  
indicate when not to read from the device to ensure that a data  
read is not attempted while the register is being updated. Take  
RDY  
care to avoid reading from the data register when the  
output is about to go low. The best method to ensure that no data  
RDY  
read occurs is to always monitor the  
output; start reading  
output goes low; and  
ensure a sufficient SCLK rate, such that the read is complete  
CS  
8-BIT COMMAND  
UP TO 24-BIT INPUT  
8-BIT CRC  
RDY  
the data register as soon as the  
CS  
before the next conversion result.  
is used to select a device. It  
CS  
DATA  
CRC  
DIN  
can be used to decode the AD7177-2 in systems where several  
components are connected to the serial bus.  
SCLK  
Figure 2 and Figure 3 show timing diagrams for interfacing to  
CS  
the AD7177-2 using  
to decode the device. Figure 2 shows  
Figure 69. SPI Write Transaction with CRC  
the timing for a read operation from the AD7177-2, and Figure 3  
shows the timing for a write operation to the AD7177-2. It is  
possible to read from the data register several times even though  
UP TO  
8-BIT COMMAND  
40-BIT OUTPUT  
8-BIT CRC  
CS  
RDY  
the  
output returns high after the first read operation.  
However, care must be taken to ensure that the read operations are  
completed before the next output update occurs. In continuous  
read mode, the data register can be read only once.  
CMD  
DIN  
DOUT/  
RDY  
DATA  
CRC  
CS  
The serial interface can operate in 3-wire mode by tying  
low.  
pins are used to  
communicate with the AD7177-2. The end of the conversion  
RDY  
RDY  
In this case, the SCLK, DIN, and DOUT/  
SCLK  
can also be monitored using the  
bit in the status register.  
CS  
The AD7177-2 can be reset by writing 64 SCLKs with  
= 0  
Figure 70. SPI Read Transaction with CRC  
and DIN = 1. A reset returns the interface to the state in which it  
expects a write to the communications register. This operation  
resets the contents of all registers to their power-on values.  
Following a reset, allow a period of 500 µs before addressing the  
serial interface.  
If checksum protection is enabled when continuous read mode  
is active, an implied read data command of 0x44 before every  
data transmission must be accounted for when calculating the  
checksum value. This implied read data command ensures a  
nonzero checksum value even if the ADC data equals 0x000000.  
CHECKSUM PROTECTION  
The AD7177-2 has a checksum mode that can be used to  
improve interface robustness. Using the checksum ensures that  
only valid data is written to a register and allows data read from  
a register to be validated. If an error occurs during a register  
write, the CRC_ERROR bit is set in the status register. However,  
to ensure that the register write is successful, read back the  
register and verify the checksum.  
Rev. B | Page 41 of 60  
 
 
 
 
AD7177-2  
Data Sheet  
To generate the checksum, the data is left shifted by eight bits to  
create a number ending in eight Logic 0s. The polynomial is  
aligned so that its MSB is adjacent to the leftmost Logic 1 of the  
data. An XOR function is applied to the data to produce a new,  
shorter number. The polynomial is again aligned so that its MSB is  
adjacent to the leftmost Logic 1 of the new result, and the proce-  
dure is repeated. This process repeats until the original data is  
reduced to a value less than the polynomial. This is the 8-bit  
checksum.  
CRC CALCULATION  
Polynomial  
The checksum, which is eight bits wide, is generated using the  
polynomial  
x8 + x2 + x + 1  
Example of a Polynomial CRC Calculation—24-Bit Word: 0x654321 (Eight Command Bits and 16-Bit Data)  
An example of generating the 8-bit checksum using the polynomial-based checksum is as follows:  
Initial value  
011001010100001100100001  
01100101010000110010000100000000  
left shifted eight bits  
polynomial  
x8 + x2 + x + 1  
=
100000111  
100100100000110010000100000000  
100000111  
XOR result  
polynomial  
XOR result  
polynomial  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
XOR result  
polynomial value  
checksum = 0x86  
100011000110010000100000000  
100000111  
11111110010000100000000  
100000111  
1111101110000100000000  
100000111  
111100000000100000000  
100000111  
11100111000100000000  
100000111  
1100100100100000000  
100000111  
100101010100000000  
100000111  
101101100000000  
100000111  
1101011000000  
100000111  
101010110000  
100000111  
1010001000  
100000111  
10000110  
Rev. B | Page 42 of 60  
 
 
Data Sheet  
AD7177-2  
XOR Calculation  
The checksum, which is 8 bits wide, is generated by splitting the data into bytes and then performing an XOR of the bytes.  
Example of an XOR Calculation—24-Bit Word: 0x654321 (Eight Command Bits and 16-Bit Data)  
Using the previous example of a polynomial CRC calculation, divide the data into three bytes: 0x65, 0x43, and 0x21.  
01100101  
01000011  
00100110  
00100001  
00000111  
0x65  
0x43  
XOR result  
0x21  
CRC  
Rev. B | Page 43 of 60  
AD7177-2  
Data Sheet  
INTEGRATED FUNCTIONS  
The AD7177-2 has integrated functions that improve the  
usefulness of a number of applications as well as serve  
diagnostic purposes in safety conscious applications.  
The effect on the noise performance depends on the delay time  
compared to the conversion time. It is possible to absorb the  
delay only for output data rates less than 10 kSPS with the  
exception of the following four rates, which cannot absorb any  
delay: 397.5 SPS, 59.92 SPS, 49.96 SPS, and 16.66 SPS.  
GENERAL-PURPOSE I/O  
The AD7177-2 has two general-purpose digital input/output pins:  
GPIO0 and GPIO1. They are enabled using the IP_EN0/IP_EN1  
bits or the OP_EN0/OP_EN1 bits in the GPIOCON register. When  
the GPIO0 or GPIO1 pin is enabled as an input, the logic level at  
the pin is contained in the GP_DATA0 or GP_DATA1 bit, respec-  
tively. When the GPIO0 or GPIO1 pin is enabled as an output, the  
GP_DATA0 or GP_DATA1 bits, respectively, determine the logic  
level output at the pin. The logic levels for these pins are  
referenced to AVDD1 and AVSS; therefore, outputs have an  
amplitude of 5 V.  
24-BIT/32-BIT CONVERSIONS  
By default, the AD7177-2 generates 24-bit conversions.  
However, the width of the conversions can be increased to 32 bits.  
Setting the WL32 bit in the interface mode register to 1 sets all  
data conversions to 32 bits. Clearing this bit sets the width of  
the data conversions to 24 bits. The WL32 bit affects the size of  
the data register but does not affect the size of the offset or gain  
registers.  
If 32-bit data conversions are enabled at the same time that the  
DATA_STAT bit is set, the ADC outputs 28 data bits and the  
four channel bits of the status register for each data read.  
SYNC ERROR  
pin can also be used as a general-purpose  
The  
output. When the ERR_EN bits in the GPIOCON register are  
SYNC ERROR  
pin operates as a general-purpose  
/
set to 11, the  
/
DOUT_RESET  
output. In this configuration, the ERR_DAT bit in the GPIOCON  
register determines the logic level output at the pin. The logic level  
for the pin is referenced to IOVDD and DGND.  
RDY  
The serial interface uses a shared DOUT/  
pin. By default,  
signal. During a data read, this pin  
outputs the data from the register being read. After the read is  
RDY  
RDY  
this pin outputs the  
SYNC ERROR  
pin, when set as general-  
Both GPIOs and the  
/
complete, the pin reverts to outputting the  
signal after a  
purpose outputs, have an active pull-up circuit.  
short fixed period of time (t7). However, this time may be too  
short for some microcontrollers and can be extended until the  
EXTERNAL MULTIPLEXER CONTROL  
CS  
pin is brought high by setting the DOUT_RESET bit in the  
If an external multiplexer is used to increase the channel count,  
the multiplexer logic pins can be controlled via the AD7177-2  
GPIOx pins. With the MUX_IO bit, the GPIOx timing is  
controlled by the ADC; therefore, the channel change is  
synchronized with the ADC, eliminating any need for external  
synchronization.  
CS  
interface mode register to 1. This means that  
to frame each read operation and compete the serial interface  
transaction.  
must be used  
SYNCHRONIZATION  
Normal Synchronization  
DELAY  
When the SYNC_EN bit in the GPIOCON register is set to 1,  
It is possible to insert a programmable delay before the AD7177-2  
begins to take samples. This delay allows an external amplifier  
or multiplexer to settle and can alleviate the specification  
requirements for the external amplifier or multiplexer. Eight  
programmable settings, ranging from 0 µs to 1 ms, can be set  
using the delay bits in the ADC mode register (Register 0x01,  
Bits[10:8]).  
SYNC ERROR  
the  
/
pin functions as a synchronization input.  
SYNC  
The  
input lets the user reset the modulator and the  
digital filter without affecting any of the setup conditions on the  
device. This feature lets the user start to gather samples of the  
SYNC  
analog input from a known point, the rising edge of the  
SYNC  
input. The  
input must be low for at least one master  
clock cycle to ensure that synchronization occurs.  
If a delay greater than 0 µs is selected and the HIDE_DELAY bit  
in the ADC mode register is set to 0, this delay is added to the  
conversion time, regardless of the selected output data rate.  
If multiple AD7177-2 devices are operated from a common  
master clock, they can be synchronized so that their analog  
inputs are sampled simultaneously. This synchronization is  
normally done after each AD7177-2 device has performed its  
own calibration or has calibration coefficients loaded into its  
When using the sinc5 + sinc1 filter, it is possible to hide this  
delay such that the output data rate remains the same as the output  
data rate without the delay enabled. If the HIDE_DELAY bit is  
set to 1 and the selected delay is less than half of the conversion  
time, the delay can be absorbed by reducing the number of  
averages the digital filter performs, which keeps the conversion  
time the same but can affect the noise performance.  
SYNC  
calibration registers. A falling edge on the  
digital filter and the analog modulator and places the AD7177-2  
SYNC  
input resets the  
into a consistent known state. While the  
input is low, the  
SYNC  
AD7177-2 is maintained in this known state. On the  
input rising edge, the modulator and filter are taken out of this  
reset state, and on the next master clock edge, the device starts to  
gather input samples again.  
Rev. B | Page 44 of 60  
 
 
 
 
 
 
 
Data Sheet  
AD7177-2  
The device is taken out of reset on the master clock falling edge  
CRC_ERROR  
SYNC  
following the  
input low to high transition. Therefore,  
SYNC  
If the CRC value that accompanies a write operation does not  
correspond with the information sent, the CRC_ERROR flag is  
set. The flag is reset as soon as the status register is explicitly read.  
when multiple devices are being synchronized, take the  
input high on the master clock rising edge to ensure that all  
devices are released on the master clock falling edge. If the  
REG_ERROR  
SYNC  
input is not taken high in sufficient time, a difference of  
The REG_ERROR flag is used in conjunction with the  
REG_CHECK bit in the interface mode register. When the  
REG_CHECK bit is set, the AD7177-2 monitors the values in  
the on-chip registers. If a bit changes, the REG_ERROR bit is  
set. Therefore, for writes to the on-chip registers, set REG_  
CHECK to 0. When the registers have been updated, the  
REG_CHECK bit can be set to 1. The AD7177-2 calculates a  
checksum of the on-chip registers. If one of the register values  
has changed, the REG_ERROR bit is set. If an error is flagged,  
the REG_CHECK bit must be set to 0 to clear the REG_ERROR  
bit in the status register. The register check function does not  
monitor the data register, status register, or interface mode  
register.  
one master clock cycle between the devices is possible; that is,  
the instant at which conversions are available differs from  
device to device by a maximum of one master clock cycle.  
SYNC  
The  
mand for a single channel when in normal synchronization  
SYNC  
input can also be used as a start conversion com-  
mode. In this mode, the rising edge of the  
RDY  
input starts a  
output indicates  
conversion, and the falling edge of the  
when the conversion is complete. The settling time of the filter is  
required for each data register update. After the conversion is  
SYNC  
complete, bring the  
input low in preparation for the next  
conversion start signal.  
Alternate Synchronization  
ERROR  
Input/Output  
When the SYNC_EN bit in the GPIOCON register is set to 0,  
SYNC ERROR  
pin functions as an error input/output pin or  
a general-purpose output pin. The ERR_EN bits in the GPIOCON  
register determine the function of the pin.  
SYNC  
In alternate synchronization mode, the  
input operates as  
a start conversion command when several channels of the  
AD7177-2 are enabled. Setting the ALT_SYNC bit in the interface  
mode register to 1 enables an alternate synchronization scheme.  
the  
/
SYNC  
When the  
conversion on the current channel, selects the next channel in  
SYNC  
input is taken low, the ADC completes the  
SYNC ERROR  
With ERR_EN is set to 10, the  
ERROR  
/
pin functions as  
the sequence, and then waits until the  
RDY  
input is taken high  
output goes low when  
an open-drain error output,  
. The three error bits in the  
to commence the conversion. The  
status register (ADC_ERROR, CRC_ERROR, and  
REG_ERROR) are ORed, inverted, and mapped to the  
the conversion is complete on the current channel, and the data  
register is updated with the corresponding conversion. Therefore,  
ERROR  
ERROR  
output. Therefore, the  
output indicates that an error  
SYNC  
the  
input does not interfere with the sampling on the  
has occurred. The status register must be read to identify the  
error source.  
currently selected channel but allows the user to control the  
instant at which the conversion begins on the next channel in  
the sequence.  
SYNC ERROR  
When ERR_EN is set to 01, the  
/
pin functions as  
. The error output of another component  
ERROR  
ERROR  
an error input,  
can be connected to the AD7177-2  
AD7177-2 indicates when an error occurs on either itself or the  
ERROR  
Alternate synchronization mode can be used only when several  
channels are enabled. It is not recommended to use this mode  
when a single channel is enabled.  
input so that the  
external component. The value on the  
input is inverted  
ERROR FLAGS  
and ORe d with the errors from the ADC conversion, and the  
result is indicated via the ADC_ERROR bit in the status register.  
The status register contains three error bits—ADC_ERROR,  
CRC_ERROR, and REG_ERROR—that flag errors with the  
ADC conversion, errors with the CRC check, and errors caused  
ERROR  
The value of the  
in the status register.  
input is reflected in the ERR_DAT bit  
ERROR  
by changes in the registers, respectively. In addition, the  
output can indicate that an error has occurred.  
ERROR  
The  
input/output is disabled when ERR_EN is set to 00.  
SYNC ERROR  
pin  
When the ERR_EN bits are set to 11, the  
operates as a general-purpose output.  
/
ADC_ERROR  
The ADC_ERROR bit in the status register flags any errors that  
occur during the conversion process. The flag is set when an over-  
range or underrange result is output from the ADC. The ADC  
also outputs all 0s or all 1s when an undervoltage or overvoltage  
occurs. This flag is reset only when the overvoltage or undervoltage  
is removed. It is not reset by a read of the data register.  
DATA_STAT  
The contents of the status register can be appended to each con-  
version on the AD7177-2. This function is useful if several  
channels are enabled. Each time a conversion is output, the  
contents of the status register are appended. The two LSBs of  
the status register indicate to which channel the conversion  
corresponds. In addition, the user can determine if any errors  
are being flagged by the error bits. If 32-bit data conversions are  
Rev. B | Page 45 of 60  
 
 
AD7177-2  
Data Sheet  
enabled at the same time that the DATA_STAT bit is set, the  
ADC outputs 28 data bits and the four channel bits of the status  
register for each data read.  
selected in the same way as an analog input channel. The  
temperature sensor requires that the analog input buffers be  
enabled on both analog inputs. If the buffers are not enabled,  
selecting the temperature sensor as an input forces the buffers  
to be enabled during the conversion.  
IOSTRENGTH  
The serial interface can operate with a power supply as low as  
To use the temperature sensor, the first step is to calibrate the  
device in a known temperature (25°C) and take a conversion as  
a reference point. The temperature sensor has a nominal sensitivity  
of 470 µV/K; the difference in this ideal slope and the slope  
measured can be used to calibrate the temperature sensor. The  
temperature sensor is specified with a 2°C typical accuracy  
after calibration at 25°C. Calibrate the temperature as follows:  
RDY  
2 V. However, at this low voltage, the DOUT/  
pin may not  
have sufficient drive strength if there is moderate parasitic  
capacitance on the board or the SCLK frequency is high. The  
IOSTRENGTH bit in the interface mode register increases the  
RDY  
drive strength of the DOUT/  
pin.  
INTERNAL TEMPERATURE SENSOR  
The AD7177-2 has an integrated temperature sensor. The  
temperature sensor can be used as a guide for the ambient  
temperature at which the device is operating. This can be used  
for diagnostic purposes or as an indicator of when the applica-  
tion circuit needs to rerun a calibration routine to take into  
account a shift in operating temperature. The temperature  
sensor is selected using the crosspoint multiplexer and is  
Conversion Result  
Temperature (°C) =  
– 273.15  
470 μV  
Rev. B | Page 46 of 60  
 
 
Data Sheet  
AD7177-2  
GROUNDING AND LAYOUT  
The analog inputs and reference inputs are differential and,  
therefore, most of the voltages in the analog modulator are  
common-mode voltages. The high common-mode rejection of  
the device removes common-mode noise on these inputs. The  
analog and digital supplies to the AD7177-2 are independent  
and connected to separate pins to minimize coupling between the  
analog and digital sections of the device. The digital filter  
provides rejection of broadband noise on the power supplies,  
except at integer multiples of the master clock frequency.  
possible to provide low impedance paths and reduce glitches on  
the power supply line. Shield fast switching signals like clocks  
with digital ground to prevent radiating noise to other sections  
of the board and never run clock signals near the analog inputs.  
Avoid crossover of digital and analog signals. Run traces on  
opposite sides of the board at right angles to each other. This  
technique reduces the effects of feedthrough on the board. A  
microstrip technique is by far the best method but is not always  
possible with a double sided board.  
The digital filter also removes noise from the analog and  
reference inputs, provided that these noise sources do not  
saturate the analog modulator. As a result, the AD7177-2 is  
more immune to noise interference than a conventional high  
resolution converter. However, because the resolution of the  
AD7177-2 is high and the noise levels from the converter are so  
low, take care with regard to grounding and layout.  
Good decoupling is important when using high resolution ADCs.  
The AD7177-2 has three power supply pins—AVDD1, AVDD2,  
and IOVDD. The AVDD1 and AVDD2 pins are referenced to  
AVSS, and the IOVDD pin is referenced to DGND. Decouple  
AVDD1 and AVDD2 with a 10 µF capacitor in parallel with a  
0.1 µF capacitor to AVSS on each pin. Place the 0.1 µF capacitor  
as close as possible to the device on each supply, ideally right up  
against the device. Decouple IOVDD with a 10 µF capacitor in  
parallel with a 0.1 µF capacitor to DGND. Decouple all analog  
inputs to AVSS. If an external reference is used, decouple the  
REF+ and REF− pins to AVSS.  
The PCB that houses the ADC must be designed such that the  
analog and digital sections are separated and confined to  
certain areas of the board. A minimum etch technique is  
generally best for ground planes because it results in the best  
shielding.  
The AD7177-2 also has two on-board LDO regulators—one  
that regulates the AVDD2 supply and one that regulates the  
IOVDD supply. For the REGCAPA pin, it is recommended that  
1 µF and 0.1 µF capacitors to AVSS be used. Similarly, for the  
REGCAPD pin, it is recommended that 1 µF and 0.1 µF capaci-  
tors to DGND be used.  
In any layout, the user must consider the flow of currents in the  
system, ensuring that the paths for all return currents are as close as  
possible to the paths the currents took to reach their destinations.  
Avoid running digital lines under the device because this  
couples noise onto the die and allows the analog ground plane  
to run under the AD7177-2 to prevent noise coupling. The  
power supply lines to the AD7177-2 must use as wide a trace as  
If using the AD7177-2 for split supply operation, a separate  
plane must be used for AVSS.  
Rev. B | Page 47 of 60  
 
AD7177-2  
Data Sheet  
REGISTER SUMMARY  
Table 24. Register Summary  
Reg. Name  
0x00 COMMS  
0x00 STATUS  
Bits  
[7:0]  
[7:0]  
Bit 7  
WEN  
RDY  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
RA  
Bit 1  
Bit 0  
Reset  
0x00  
0x80  
RW  
W
W
R/  
HIDE_DELAY  
CHANNEL  
R
0x01 ADCMODE  
[15:8]  
[7:0]  
REF_EN  
SING_CYC  
MODE  
RESERVED  
DELAY  
RESERVED  
0x8000  
RW  
RW  
R
RESERVED  
CLOCKSEL  
0x02 IFMODE  
[15:8]  
[7:0]  
RESERVED  
ALT_SYNC  
REGISTER_CHECK[23:16]  
IOSTRENGTH  
RESERVED  
DOUT_RESET 0x0000  
RESERVED  
CONTREAD  
0x03 REGCHECK  
[23:16]  
[15:8]  
[7:0]  
0x000000  
REGISTER_CHECK[15:8]  
REGISTER_CHECK[7:0]  
DATA[31:17]  
0x04 DATA  
[31:17]  
[23:16]  
[15:8]  
[7:0]  
0x000000  
R
DATA[23:16]  
DATA[15:8]  
DATA[7:0]  
0x06 GPIOCON  
0x07 ID  
[15:8]  
[7:0]  
RESERVED  
MUX_IO  
SYNC_EN  
ERR_EN  
ERR_DAT  
0x0800  
0x4FDX  
0x8001  
0x0001  
0x0001  
0x0001  
RW  
R
RESERVED  
GP_DATA0  
[15:8]  
[7:0]  
ID[15:8]  
ID[7:0]  
0x10 CH0  
[15:8]  
[7:0]  
CH_EN0  
CH_EN1  
CH_EN2  
CH_EN3  
RESERVED  
AINPOS0[2:0]  
RESERVED  
AINPOS1[2:0]  
RESERVED  
AINPOS2[2:0]  
RESERVED  
AINPOS3[2:0]  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
SETUP_SEL0  
SETUP_SEL1  
SETUP_SEL2  
SETUP_SEL3  
RESERVED  
AINNEG0  
RESERVED  
AINNEG1  
RESERVED  
AINNEG2  
RESERVED  
AINNEG3  
REFBUF0-  
AINPOS0[4:3]  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
0x11 CH1  
[15:8]  
[7:0]  
AINPOS1[4:3]  
AINPOS2[4:3]  
AINPOS3[4:3]  
0x12 CH2  
[15:8]  
[7:0]  
0x13 CH3  
[15:8]  
[7:0]  
0x20 SETUPCON0  
0x21 SETUPCON1  
0x22 SETUPCON2  
0x23 SETUPCON3  
0x28 FILTCON0  
0x29 FILTCON1  
0x2A FILTCON2  
0x2B FILTCON3  
[15:8]  
[7:0]  
BI_UNIPOLAR0  
REF_SEL0  
BI_UNIPOLAR1  
REF_SEL1  
BI_UNIPOLAR2  
REF_SEL2  
BI_UNIPOLAR3  
REF_SEL3  
RESERVED  
ORDER0  
REFBUF0+  
REFBUF1+  
REFBUF2+  
REFBUF3+  
AINBUF0+  
AINBUF1+  
AINBUF0− 0x1320  
AINBUF1− 0x1320  
AINBUF2− 0x1320  
AINBUF3− 0x1320  
0x0507  
BURNOUT_EN0  
BURNOUT_EN1  
BURNOUT_EN2  
RESERVED  
[15:8]  
[7:0]  
REFBUF1−  
RESERVED  
[15:8]  
[7:0]  
REFBUF2−  
AINBUF2+  
RESERVED  
[15:8]  
[7:0]  
REFBUF3−  
AINBUF3+  
BURNOUT_EN3  
SINC3_MAP0  
RESERVED  
RESERVED  
[15:8]  
[7:0]  
ENHFILTEN0  
ENHFILTEN1  
ENHFILTEN2  
ENHFILTEN3  
ENHFILT0  
ENHFILT1  
ENHFILT2  
ENHFILT3  
ODR0  
ODR1  
ODR2  
ODR3  
[15:8]  
[7:0]  
SINC3_MAP1  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
0x0507  
ORDER1  
ORDER2  
ORDER3  
[15:8]  
[7:0]  
SINC3_MAP2  
RESERVED  
0x0507  
[15:8]  
[7:0]  
SINC3_MAP3  
RESERVED  
0x0507  
0x30 OFFSET0  
0x31 OFFSET1  
0x32 OFFSET2  
0x33 OFFSET3  
0x38 GAIN0  
0x39 GAIN1  
0x3A GAIN2  
0x3B GAIN3  
[23:0]  
[23:0]  
[23:0]  
[23:0]  
[23:0]  
[23:0]  
[23:0]  
[23:0]  
OFFSET0[23:0]  
0x800000 RW  
0x800000 RW  
0x800000 RW  
0x800000 RW  
0x5XXXX0 RW  
0x5XXXX0 RW  
0x5XXXX0 RW  
0x5XXXX0 RW  
OFFSET1[23:0]  
OFFSET2[23:0]  
OFFSET3[23:0]  
GAIN0[23:0]  
GAIN1[23:0]  
GAIN2[23:0]  
GAIN3[23:0]  
Rev. B | Page 48 of 60  
 
Data Sheet  
AD7177-2  
REGISTER DETAILS  
COMMUNICATIONS REGISTER  
Address: 0x00, Reset: 0x00, Name: COMMS  
All access to the on-chip registers must start with a write to the communications register. This write determines what register is accessed  
next and whether that operation is a write or a read.  
Table 25. Bit Descriptions for COMMS  
Bits  
Bit Name  
Settings  
Description  
Reset  
0x0  
Access  
W
7
WEN  
This bit must be low to begin communications with the ADC.  
6
R/W  
This bit determines if the command is a read or write operation.  
0x0  
W
0
1
Write command  
Read command  
[5:0]  
RA  
The register address bits determine which register is to be read from or  
written to as part of the current communication.  
0x00  
W
000000 Status register  
000001 ADC mode register  
000010 Interface mode register  
000011 Register checksum register  
000100 Data register  
000110 GPIO configuration register  
000111 ID register  
010000 Channel 0 register  
010001 Channel 1 register  
010010 Channel 2 register  
010011 Channel 3 register  
100000 Setup Configuration 0 register  
100001 Setup Configuration 1 register  
100010 Setup Configuration 2 register  
100011 Setup Configuration 3 register  
101000 Filter Configuration 0 register  
101001 Filter Configuration 1 register  
101010 Filter Configuration 2 register  
101011 Filter Configuration 3 register  
110000 Offset 0 register  
110001 Offset 1 register  
110010 Offset 2 register  
110011 Offset 3 register  
111000 Gain 0 register  
111001 Gain 1 register  
111010 Gain 2 register  
111011 Gain 3 register  
Rev. B | Page 49 of 60  
 
 
AD7177-2  
Data Sheet  
STATUS REGISTER  
Address: 0x00, Reset: 0x80, Name: STATUS  
The status register is an 8-bit register that contains ADC and serial interface status information. It can optionally be appended to the data  
register by setting the DATA_STAT bit in the interface mode register.  
Table 26. Bit Descriptions for STATUS  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
7
RDY  
The status of RDY is output to the DOUT/RDYpin whenever CS is low and a 0x1  
register is not being read. This bit goes low when the ADC has written a  
new result to the data register. In ADC calibration modes, this bit goes low  
when the ADC has written the calibration result. RDY is brought high  
automatically by a read of the data register.  
R
0
1
New data result available  
Awaiting new data result  
6
ADC_ERROR  
This bit by default indicates if an ADC overrange or underrange has  
occurred. The ADC result is clamped to 0xFFFFFF for overrange errors and  
0x000000 for underrange errors. This bit is updated when the ADC result is  
written and is cleared at the next update after removing the overrange or  
underrange condition.  
0x0  
R
0
1
No error  
Error  
5
4
CRC_ERROR  
REG_ERROR  
This bit indicates if a CRC error has taken place during a register write. For  
register reads, the host microcontroller determines if a CRC error has  
occurred. This bit is cleared by a read of this register.  
No error  
CRC error  
0x0  
0x0  
R
R
0
1
This bit indicates if the content of one of the internal registers has  
changed from the value calculated when the register integrity check was  
activated. The check is activated by setting the REG_CHECK bit in the  
interface mode register. This bit is cleared by clearing the REG_CHECK bit.  
0
1
No error  
Error  
[3:2]  
[1:0]  
RESERVED  
CHANNEL  
These bits are reserved.  
0x0  
0x0  
R
R
These bits indicate which channel was active for the ADC conversion  
whose result is currently in the data register. This may be different from  
the channel currently being converted. The mapping is a direct map from  
the channel register; therefore, Channel 0 results in 0x0 and Channel 3  
results in 0x3.  
00 Channel 0  
01 Channel 1  
10 Channel 2  
11 Channel 3  
Rev. B | Page 50 of 60  
 
Data Sheet  
AD7177-2  
ADC MODE REGISTER  
Address: 0x01, Reset: 0x8000, Name: ADCMODE  
The ADC mode register controls the operating mode of the ADC and the master clock selection. A write to the ADC mode register resets  
the filter and the bits and starts a new conversion or calibration.  
RDY  
Table 27. Bit Descriptions for ADCMODE  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
15  
REF_EN  
Enables internal reference and outputs a buffered 2.5 V to the REFOUT pin. 0x1  
RW  
0
1
Disabled  
Enabled  
14  
13  
HIDE_DELAY  
SING_CYC  
If a programmable delay is set using the delay bits, this bit allows the  
delay to be hidden by absorbing the delay into the conversion time for  
selected data rates with the sinc5 + sinc1 filter. See the Delay section for  
more information.  
Enabled  
Disabled  
0x0  
RW  
RW  
0
1
This bit can be used when only a single channel is active to set the ADC to 0x0  
only output at the settled filter data rate.  
0
1
Disabled  
Enabled  
[12:11] RESERVED  
These bits are reserved; set these bits to 0.  
0x0  
R
[10:8]  
DELAY  
These bits allow a programmable delay to be added after a channel switch 0x0  
to allow the settling of external circuitry before the ADC starts processing  
its input.  
RW  
000 0 μs  
001 4 μs  
010 16 μs  
011 40 μs  
100 100 μs  
101 200 μs  
110 500 μs  
111 1 ms  
7
RESERVED  
MODE  
This bit is reserved; set this bit to 0.  
0x0  
0x0  
R
[6:4]  
These bits control the operating mode of the ADC. See the Operating  
Modes section for more information.  
RW  
000 Continuous conversion mode  
001 Single conversion mode  
010 Standby mode  
011 Power-down mode  
100 Internal offset calibration  
110 System offset calibration  
111 System gain calibration  
[3:2]  
[1:0]  
CLOCKSEL  
RESERVED  
These bits are used to select the ADC clock source. Selecting the internal  
oscillator also enables the internal oscillator.  
00 Internal oscillator  
01 Internal oscillator output on the XTAL2/CLKIO pin  
10 External clock input on the XTAL2/CLKIO pin  
11 External crystal on the XTAL1 and XTAL2/CLKIO pins  
These bits are reserved; set these bits to 0.  
0x0  
0x0  
RW  
R
Rev. B | Page 51 of 60  
 
 
AD7177-2  
Data Sheet  
INTERFACE MODE REGISTER  
Address: 0x02, Reset: 0x0000, Name: IFMODE  
The interface mode register configures various serial interface options.  
Table 28. Bit Descriptions for IFMODE  
Bits  
Bit Name  
Settings  
Description  
Reset  
0x0  
Access  
R
[15:13] RESERVED  
These bits are reserved; set these bits to 0.  
12  
11  
ALT_SYNC  
This bit enables a different behavior of the SYNC/ERROR pin to allow the  
use of SYNC/ERROR as a control for conversions when cycling channels  
(see the description of the SYNC_EN bit in the GPIO Configuration Register  
section for details).  
Disabled  
Enabled  
0x0  
RW  
0
1
IOSTRENGTH  
This bit controls the drive strength of the DOUT/RDY pin. Set this bit  
when reading from the serial interface at high speed with a low IOVDD  
supply and moderate capacitance.  
0x0  
RW  
0
1
Disabled (default)  
Enabled  
[10:9]  
8
RESERVED  
These bits are reserved; set these bits to 0.  
0x0  
0x0  
R
DOUT_RESET  
See the DOUT_RESET section for more information.  
RW  
0
1
Disabled  
Enabled  
7
6
CONTREAD  
DATA_STAT  
This bit enables continuous read mode of the ADC data register. The ADC 0x0  
must be configured in continuous conversion mode to use continuous  
read mode. For more details, see the Operating Modes section.  
Disabled  
Enabled  
RW  
RW  
0
1
This bit enables the status register to be appended to the data register  
when read so that channel and status information are transmitted with  
the data. This is the only way to be sure that the channel bits read from  
the status register correspond to the data in the data register.  
0x0  
0
1
Disabled  
Enabled  
5
REG_CHECK  
This bit enables a register integrity checker, which can be used to  
monitor any change in the value of the user registers. To use this feature,  
configure all other registers as desired with this bit cleared. Then write to this  
register to set the REG_CHECK bit to 1. If the contents of any of the  
registers change, the REG_ERROR bit is set in the status register. To clear  
the error, set the REG_CHECK bit to 0. Neither the interface mode register  
nor the ADC data or status registers are included in the registers that are  
checked. If a register must have a new value written, this bit must first be  
cleared; otherwise, an error is flagged when the new register contents  
are written.  
0x0  
RW  
0
1
Disabled  
Enabled  
4
RESERVED  
CRC_EN  
This bit is reserved; set this bit to 0.  
0x0  
R
[3:2]  
These bits enable CRC protection of register reads/writes. CRC increases  
the number of bytes in a serial interface transfer by one. See the CRC  
Calculation section for more details.  
0x00  
RW  
00 Disabled  
01 XOR checksum enabled for register read transactions; register writes still  
use CRC with these bits set  
10 CRC checksum enabled for read and write transactions  
Rev. B | Page 52 of 60  
 
 
Data Sheet  
AD7177-2  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
1
WL32  
This bit changes the ADC data register length. The ADC is not reset by a  
write to the interface mode register; therefore, the ADC result is not  
changed to the correct word length immediately after writing to these  
bits. The first new ADC result is correct.  
0x0  
RW  
0
1
24-bit data  
32-bit data  
0
RESERVED  
This bit is reserved; set this bit to 0.  
0x0  
R
REGISTER CHECK  
Address: 0x03, Reset: 0x000000, Name: REGCHECK  
The register check register is a 24-bit checksum calculated by exclusively OR'ing the contents of the user registers. The REG_CHECK bit  
in the interface mode register must be set for this to operate; otherwise, the register reads 0.  
Table 29. Bit Descriptions for REGCHECK  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
[23:0]  
REGISTER_CHECK  
This register contains the 24-bit checksum of user registers when the  
REG_CHECK bit is set in the interface mode register.  
0x000000  
R
DATA REGISTER  
Address: 0x04, Reset: 0x000000, Name: DATA  
The data register contains the ADC conversion result. The encoding is offset binary, or it can be changed to unipolar by the  
RDY RDY  
output high if it is  
BI_UNIPOLARx bits in the setup configuration registers. Reading the data register brings the  
bit and the  
output is brought high, it is not possible to know if another  
RDY  
low. The ADC result can be read multiple times; however, because the  
ADC result is imminent. After the command to read the ADC register is received, the ADC does not write a new result into the data  
register.  
Table 30. Bit Descriptions for DATA  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
[31:0]  
DATA  
This register contains the ADC conversion result. The size of this register  
is determined by the WL32 bits in the interface mode register.  
0x000000  
R
Rev. B | Page 53 of 60  
 
 
AD7177-2  
Data Sheet  
GPIO CONFIGURATION REGISTER  
Address: 0x06, Reset: 0x0800, Name: GPIOCON  
The GPIO configuration register controls the general-purpose I/O pins of the ADC.  
Table 31. Bit Descriptions for GPIOCON  
Bits  
Bit Name  
Settings Description  
Reset  
0x0  
Access  
R
[15:13] RESERVED  
These bits are reserved; set these bits to 0.  
12  
11  
MUX_IO  
This bit allows the ADC to control an external multiplexer, using GPIO0/GPIO1 in sync  
with the internal channel sequencing. The analog input pins used for a channel  
can still be selected on a per channel basis. Therefore, it is possible to have a  
4-channel multiplexer in front of AIN0/AIN1 and another in front of AIN2/AIN3, giving a  
total of eight differential channels with the AD7177-2. However, only four channels at  
a time can be automatically sequenced. A delay can be inserted after switching an  
external multiplexer (see the DELAY bits in the ADC Mode Register section).  
0x0  
RW  
SYNC_EN  
This bit enables the SYNC/ERROR pin as a sync input. When the pin is low, this  
holds the ADC and filter in reset until the SYNC/ERROR pin goes high. An  
alternative operation of the SYNC/ERROR pin is available when the ALT_SYNC bit  
in the interface mode register is set. This mode only works when multiple channels  
are enabled. In this case, a low on the SYNC/ERROR pin does not immediately reset  
the filter/modulator. Instead, if the SYNC/ERROR pin is low when the channel is  
due to be switched, the modulator and filter are prevented from starting a new  
conversion. Bringing SYNC/ERROR high begins the next conversion. This alterna-  
tive sync mode allows SYNC/ERROR to be used while cycling through channels.  
0x1  
RW  
0
1
Disabled.  
Enabled.  
[10:9]  
ERR_EN  
These bits enable the SYNC/ERROR pin as an error input/output.  
0x0  
RW  
00 Disabled.  
01 SYNC/ERROR is an error input. The (inverted) readback state is OR'ed with other  
error sources and is available in the ADC_ERROR bit in the status register. The SYNC/  
ERROR pin state can also be read from the ERR_DAT bit in this register.  
10 SYNC/ERROR is an open-drain error output. The status register error bits are OR'ed,  
inverted, and mapped to the SYNC/ERROR pin. The SYNC/ERROR pins of multiple  
devices can be wired together to a common pull-up resistor so that an error on  
any device can be observed.  
11 SYNC/ERROR is a general-purpose output. The status of the pin is controlled by the  
ERR_DAT bit in this register. This output is referenced between IOVDD and DGND,  
as opposed to the AVDD1 and AVSS levels used by the general-purpose I/O pins.  
The SYNC/ERROR pin has an active pull-up in this case.  
8
ERR_DAT  
This bit determines the logic level at the SYNC/ERROR pin if the pin is enabled as a  
general-purpose output. This bit reflects the readback status of the pin if the pin is  
enabled as an input.  
0x0  
RW  
[7:6]  
5
RESERVED  
IP_EN1  
These bits are reserved; set these bits to 0.  
0x0  
0x0  
R
This bit turns GPIO1 into an input. Inputs are referenced to AVDD1 or AVSS.  
RW  
0
1
Disabled.  
Enabled.  
4
3
2
IP_EN0  
This bit turns GPIO0 into an input. Inputs are referenced to AVDD1 or AVSS.  
Disabled.  
Enabled.  
0x0  
RW  
RW  
RW  
0
1
OP_EN1  
OP_EN0  
This bit turns GPIO1 into an output. Outputs are referenced between AVDD1 and AVSS. 0x0  
Disabled.  
Enabled.  
0
1
This bit turns GPIO0 into an output. Outputs are referenced between AVDD1 and AVSS. 0x0  
0
1
Disabled.  
Enabled.  
1
0
GP_DATA1  
GP_DATA0  
This bit is the readback or write data for GPIO1.  
This bit is the readback or write data for GPIO0.  
0x0  
0x0  
RW  
RW  
Rev. B | Page 54 of 60  
 
Data Sheet  
AD7177-2  
ID REGISTER  
Address: 0x07, Reset: 0x4FDX, Name: ID  
The ID register returns a 16-bit ID. For the AD7177-2, this ID is 0x4FDX.  
Table 32. Bit Descriptions for ID  
Bits  
Bit Name  
Settings  
Description  
Reset  
0x4FDX  
Access  
[15:0]  
ID  
The ID register returns a 16-bit ID code that is specific to the ADC.  
R
0x4FDX AD7177-2  
CHANNEL REGISTER 0  
Address: 0x10, Reset: 0x8001, Name: CH0  
The channel registers are 16-bit registers used to select which channels are currently active, which inputs are selected for each channel,  
and which setup is used to configure the ADC for that channel.  
Table 33. Bit Descriptions for CH0  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
15  
CH_EN0  
This bit enables Channel 0. If more than one channel is enabled, the ADC  
automatically sequences between them.  
0x1  
RW  
0
1
Disabled  
Enabled (default)  
14  
RESERVED  
This bit is reserved; set this bit to 0.  
0x0  
0x0  
R
[13:12] SETUP_SEL0  
These bits identify which of the four setups is used to configure the ADC  
for this channel. A setup comprises a set of four registers: setup configuration  
register, filter configuration register, offset register, and gain register. All  
channels can use the same setup, in which case the same 2-bit value must be  
written to these bits on all active channels, or up to four channels can be  
configured differently.  
RW  
00 Setup 0  
01 Setup 1  
10 Setup 2  
11 Setup 3  
[11:10] RESERVED  
[9:5] AINPOS0  
These bits are reserved; set these bits to 0.  
0x0  
0x0  
R
These bits select which input is connected to the positive input of the  
ADC for this channel.  
RW  
00000 AIN0 (default)  
00001 AIN1  
00010 AIN2  
00011 AIN3  
00100 AIN4  
10001 Temperature sensor+  
10010 Temperature sensor−  
10011 ((AVDD1 − AVSS)/5)+ (analog input buffers must be enabled)  
10100 ((AVDD1 − AVSS)/5)− (analog input buffers must be enabled)  
10101 REF+  
10110 REF−  
Rev. B | Page 55 of 60  
 
 
AD7177-2  
Data Sheet  
Bits  
Bit Name  
AINNEG0  
Settings  
Description  
Reset  
Access  
[4:0]  
These bits select which input is connected to the negative input of the  
ADC for this channel.  
0x1  
RW  
00000 AIN0  
00001 AIN1 (default)  
00010 AIN2  
00011 AIN3  
00100 AIN4  
10001 Temperature sensor+  
10010 Temperature sensor−  
10011 ((AVDD1 − AVSS)/5)+  
10100 ((AVDD1 − AVSS)/5)−  
10101 REF+  
10110 REF−  
CHANNEL REGISTER 1 TO CHANNEL REGISTER 3  
Address: 0x11 to 0x13, Reset: 0x0001, Name: CH1 to CH3  
The remaining three channel registers share the same layout as Channel Register 0.  
Table 34. CH1 to CH3 Register Map  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reset  
RW  
0x11  
CH1  
[15:8]  
[7:0]  
CH_EN1  
RESERVED  
AINPOS1[2:0]  
SETUP_SEL1  
RESERVED  
AINPOS1[4:3]  
0x0001  
0x0001  
0x0001  
RW  
AINNEG1  
RESERVED  
AINNEG2  
RESERVED  
AINNEG3  
0x12  
0x13  
CH2  
CH3  
[15:8]  
[7:0]  
CH_EN2  
CH_EN3  
RESERVED  
SETUP_SEL2  
SETUP_SEL3  
AINPOS2[4:3]  
AINPOS3[4:3]  
RW  
RW  
AINPOS2[2:0]  
[15:8]  
[7:0]  
RESERVED  
AINPOS3[2:0]  
Rev. B | Page 56 of 60  
 
Data Sheet  
AD7177-2  
SETUP CONFIGURATION REGISTER 0  
Address: 0x20, Reset: 0x1320, Name: SETUPCON0  
The setup configuration registers are 16-bit registers that configure the reference selection, input buffers, and output coding of the ADC.  
Table 35. Bit Descriptions for SETUPCON0  
Bits  
Bit Name  
Settings  
Description  
Reset  
0x0  
Access  
R
[15:13] RESERVED  
These bits are reserved; set these bits to 0.  
This bit sets the output coding of the ADC for Setup 0.  
Unipolar coded output  
Bipolar coded output (offset binary)  
This bit enables or disables the REF+ input buffer.  
REF+ buffer disabled  
12  
11  
10  
9
BI_UNIPOLAR0  
0x1  
RW  
0
1
REFBUF0+  
REFBUF0−  
AINBUF0+  
AINBUF0−  
BURNOUT_EN0  
0x0  
0x0  
0x1  
0x1  
0x00  
RW  
RW  
RW  
RW  
R
0
1
REF+ buffer enabled  
This bit enables or disables the REF− input buffer.  
REF− buffer disabled  
REF− buffer enabled  
0
1
This bit enables or disables the AIN+ input buffer.  
AIN+ buffer disabled  
AIN+ buffer enabled  
0
1
8
This bit enables or disables the AIN− input buffer.  
AIN− buffer disabled  
AIN− buffer enabled  
0
1
7
This bit enables a 10 μA current source on the positive analog input  
selected and a 10 μA current sink on the negative analog input selected.  
The burnout currents are useful in diagnosis of an open wire, whereby the  
ADC result goes to full scale. Enabling the burnout currents during  
measurement results in an offset voltage on the ADC. This means the  
strategy for diagnosing an open wire operates best by turning on the  
burnout currents at intervals, before or after precision measurements.  
6
RESERVED  
REF_SEL0  
These bits are reserved; set these bits to 0.  
0x00  
0x2  
R
[5:4]  
These bits allow the user to select the reference source for ADC  
conversion on Setup 0.  
RW  
00 External reference.  
10 Internal 2.5 V reference. This must also be enabled in the ADC mode register.  
11 AVDD1 − AVSS. This can be used to as a diagnostic to validate other  
reference values.  
[3:0]  
RESERVED  
These bits are reserved; set these bits to 0.  
0x0  
R
SETUP CONFIGURATION REGISTER 1 TO SETUP CONFIGURATION REGISTER 3  
Address: 0x21 to 0x23, Reset: 0x1320, Name: SETUPCON1 to SETUPCON3  
The remaining three setup configuration registers share the same layout as Setup Configuration Register 0.  
Table 36. SETUPCON1 to SETUPCON3 Register Map  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reset  
RW  
0x21  
SETUPCON1  
[15:8]  
[7:0]  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
RESERVED  
BI_UNIPOLAR1  
REFBUF1+  
REFBUF1−  
AINBUF1+  
AINBUF1−  
AINBUF2−  
AINBUF3−  
0x1320  
0x1320  
0x1320  
RW  
BURNOUT_EN1  
BURNOUT_EN2  
BURNOUT_EN3  
REF_SEL1  
BI_UNIPOLAR2  
REF_SEL2  
BI_UNIPOLAR3  
REF_SEL3  
RESERVED  
0x22  
0x23  
SETUPCON2  
SETUPCON3  
[15:8]  
[7:0]  
REFBUF2+  
REFBUF3+  
REFBUF2−  
AINBUF2+  
RW  
RW  
RESERVED  
[15:8]  
[7:0]  
REFBUF3−  
AINBUF3+  
RESERVED  
Rev. B | Page 57 of 60  
 
 
AD7177-2  
Data Sheet  
FILTER CONFIGURATION REGISTER 0  
Address: 0x28, Reset: 0x0507, Name: FILTCON0  
The filter configuration registers are 16-bit registers that configure the ADC data rate and filter options. Writing to any of these registers  
resets any active ADC conversion and restarts converting at the first channel in the sequence.  
Table 37. Bit Descriptions for FILTCON0  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
15  
SINC3_MAP0  
If this bit is set, the mapping of the filter register changes to directly  
program the decimation rate of the sinc3 filter for Setup 0. All other  
options are eliminated. This allows fine tuning of the output data rate  
and filter notch for rejection of specific frequencies. The data rate when  
on a single channel equals fMOD/(32 × FILTCON0[14:0]).  
0x0  
RW  
[14:12] RESERVED  
These bits are reserved; set these bits to 0.  
0x0  
0x0  
R
11  
ENHFILTEN0  
This bit enables various postfilters for enhanced 50 Hz/60 Hz rejection  
for Setup 0. The ORDER0 bits must be set to 00 to select the sinc5 +  
sinc1 filter for this to work.  
RW  
0
1
Disabled  
Enabled  
[10:8]  
ENHFILT0  
These bits select between various postfilters for enhanced 50 Hz/60 Hz  
rejection for Setup 0.  
0x5  
RW  
010 27 SPS, 47 dB rejection, 36.7 ms settling  
011 25 SPS, 62 dB rejection, 40 ms settling  
101 20 SPS, 85 dB rejection, 50 ms settling  
110 16.67 SPS, 92 dB rejection, 60 ms settling  
This bit is reserved; set this bit to 0.  
7
RESERVED  
ORDER0  
0x0  
0x0  
R
[6:5]  
These bits control the order of the digital filter that processes the  
modulator data for Setup 0.  
RW  
00 Sinc5 + sinc1 (default)  
11 Sinc3  
[4:0]  
ODR0  
These bits control the output data rate of the ADC and, therefore, the  
settling time and noise for Setup 0. Rates shown are for the sinc5 + sinc  
1 filter. See Table 19 to Table 22.  
0x07  
RW  
00000 to Reserved  
00110  
00111 10,000 SPS  
01000 5000 SPS  
01001 2500 SPS  
01010 1000 SPS  
01011 500 SPS  
01100 397.5 SPS  
01101 200 SPS  
01110 100 SPS  
01111 59.92 SPS  
10000 49.96 SPS  
10001 20 SPS  
10010 16.66 SPS  
10011 10 SPS  
10100 5 SPS  
Rev. B | Page 58 of 60  
 
Data Sheet  
AD7177-2  
FILTER CONFIGURATION REGISTER 1 TO FILTER CONFIGURATION REGISTER 3  
Address: 0x29 to 0x2B, Reset: 0x0507, Name: FILTCON1 to FILTCON3  
The remaining three filter configuration registers share the same layout as Filter Configuration Register 0.  
Table 38. FILTCON1 to FILTCON3 Register Map  
Reg.  
Name  
Bits  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
ODR1  
Bit 1  
ENHFILT1  
Bit 0  
Reset  
RW  
0x29  
FILTCON1  
[15:8]  
[7:0]  
SINC3_MAP1  
RESERVED  
RESERVED  
ENHFILTEN1  
0x0507  
RW  
ORDER1  
RESERVED  
ORDER2  
RESERVED  
ORDER3  
0x2A  
0x2B  
FILTCON2  
FILTCON3  
[15:8]  
[7:0]  
SINC3_MAP2  
RESERVED  
ENHFILTEN2  
ENHFILTEN3  
ENHFILT2  
ENHFILT3  
0x0507  
0x0507  
RW  
RW  
ODR2  
ODR3  
[15:8]  
[7:0]  
SINC3_MAP3  
RESERVED  
OFFSET REGISTER 0  
Address: 0x30, Reset: 0x800000, Name: OFFSET0  
The offset (zero-scale) registers are 24-bit registers that can be used to compensate for any offset error in the ADC or in the system.  
Table 39. Bit Descriptions for OFFSET0  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
[23:0]  
OFFSET0  
Offset calibration coefficient for Setup 0.  
0x800000 RW  
OFFSET REGISTER 1 TO OFFSET REGISTER 3  
Address: 0x31 to 0x33, Reset: 0x800000, Name: OFFSET1 to OFFSET3  
The remaining three offset registers share the same layout as Offset Register 0.  
Table 40. OFFSET1 to OFFSET3 Register Map  
Reg. Name  
Bits  
Reset  
RW  
0x31 OFFSET1  
0x32 OFFSET2  
0x33 OFFSET3  
OFFSET1[23:0]  
OFFSET2[23:0]  
OFFSET3[23:0]  
0x800000 RW  
0x800000 RW  
0x800000 RW  
GAIN REGISTER 0  
Address: 0x38, Reset: 0x5XXXX0, Name: GAIN0  
The gain (full-scale) registers are 24-bit registers that can be used to compensate for any gain error in the ADC or in the system.  
Table 41. Bit Descriptions for GAIN0  
Bits  
Bit Name  
Settings  
Description  
Reset  
Access  
[23:0]  
GAIN0  
Gain calibration coefficient for Setup 0.  
0x5XXXX0 RW  
GAIN REGISTER 1 TO GAIN REGISTER 3  
Address: 0x39 to 0x3B, Reset: 0x5XXXX0, Name: GAIN1 to GAIN3  
The remaining three gain registers share the same layout as Gain Register 0.  
Table 42. GAIN1 to GAIN3 Register Map  
Reg. Name  
0x39 GAIN1  
0x3A GAIN2  
0x3B GAIN3  
Bits  
Reset  
RW  
GAIN1[23:0]  
GAIN2[23:0]  
GAIN3[23:0]  
0x5XXXX0 RW  
0x5XXXX0 RW  
0x5XXXX0 RW  
Rev. B | Page 59 of 60  
 
 
 
 
 
AD7177-2  
Data Sheet  
OUTLINE DIMENSIONS  
7.90  
7.80  
7.70  
24  
13  
12  
4.50  
4.40  
4.30  
6.40 BSC  
1
PIN 1  
0.65  
BSC  
1.20  
MAX  
0.15  
0.05  
0.75  
0.60  
0.45  
8°  
0°  
0.30  
0.19  
0.20  
0.09  
SEATING  
PLANE  
0.10 COPLANARITY  
COMPLIANT TO JEDEC STANDARDS MO-153-AD  
Figure 71. 24-Lead Thin Shrink Small Outline Package [TSSOP]  
(RU-24)  
Dimensions shown in millimeters  
ORDERING GUIDE  
Model1  
Temperature Range  
Package Description  
Package Option  
AD7177-2BRUZ  
AD7177-2BRUZ-RL7  
−40°C to +105°C  
−40°C to +105°C  
24-Lead Thin Shrink Small Outline Package [TSSOP]  
24-Lead Thin Shrink Small Outline Package [TSSOP]  
RU-24  
RU-24  
1 Z = RoHS Compliant Part.  
©2015–2016 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective owners.  
D12912-0-3/16(B)  
Rev. B | Page 60 of 60  
 
 
 

相关型号:

AD7177-2BRUZ-RL7

32-Bit, 10 kSPS, Sigma-Delta ADC with 100 &#181;s Settling and True Rail-to-Rail Buffers
ADI

AD7177-2_17

32-Bit, 10 kSPS, Sigma-Delta ADC with Settling and True Rail-to-Rail Buffers
ADI

AD7183

Advanced Video Decoder with 10-Bit ADC and Component Input Support
ADI

AD7190

4.8 kHz Ultra-Low Noise 24-Bit Sigma-Delta ADC with PGA
ADI

AD7190BRUZ

4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA
ADI

AD7190BRUZ-REEL

4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA
ADI

AD7190WBRUZ

4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA
ADI

AD7190WBRUZ-RL

1-CH 24-BIT DELTA-SIGMA ADC, SERIAL ACCESS, PDSO24, ROHS COMPLIANT, TSSOP-24
ADI

AD7190_08

4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA
ADI

AD7191

Pin-Programmable, Ultralow Noise, 24-Bit, Sigma-Delta ADC for Bridge Sensors
ADI

AD7191BRUZ

Pin-Programmable, Ultralow Noise, 24-Bit, Sigma-Delta ADC for Bridge Sensors
ADI

AD7191BRUZ

1-CH 24-BIT DELTA-SIGMA ADC, SERIAL ACCESS, PDSO24, ROHS COMPLIANT, PLASTIC, MO-153AD, TSSOP-24