AD7177-2BRUZ [ADI]
32-Bit, 10 kSPS, Sigma-Delta ADC with 100 µs Settling and True Rail-to-Rail Buffers;型号: | AD7177-2BRUZ |
厂家: | ADI |
描述: | 32-Bit, 10 kSPS, Sigma-Delta ADC with 100 µs Settling and True Rail-to-Rail Buffers 光电二极管 转换器 |
文件: | 总61页 (文件大小:977K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
32-Bit, 10 kSPS, Sigma-Delta ADC with 100 µs
Settling and True Rail-to-Rail Buffers
Data Sheet
AD7177-2
FEATURES
GENERAL DESCRIPTION
32-bit data output
Fast and flexible output rate: 5 SPS to 10 kSPS
Channel scan data rate of 10 kSPS/channel (100 µs settling)
Performance specifications
19.1 noise free bits at 10 kSPS
The AD7177-2 is a 32-bit low noise, fast settling, multiplexed,
2-/4-channel (fully/pseudo differential) Σ-Δ analog-to-digital
converter (ADC) for low bandwidth inputs. It has a maximum
channel scan rate of 10 kSPS (100 µs) for fully settled data. The
output data rates range from 5 SPS to 10 kSPS.
20.2 noise free bits at 2.5 kSPS
The AD7177-2 integrates key analog and digital signal condition-
ing blocks to allow users to configure an individual setup for
each analog input channel in use. Each feature can be user selected
on a per channel basis. Integrated true rail-to-rail buffers on the
analog inputs and external reference inputs provide easy to drive
high impedance inputs. The precision 2.5 V low drift (2 ppm/°C)
band gap internal reference (with output reference buffer) adds
embedded functionality to reduce external component count.
24.6 noise free bits at 5 SPS
INL: 1 ppm of FSR
85 dB filter rejection of 50 Hz and 60 Hz with 50 ms settling
User configurable input channels
2 fully differential channels or 4 single-ended channels
Crosspoint multiplexer
On-chip 2.5 V reference ( 2 ppm/°C drift)
True rail-to-rail analog and reference input buffers
Internal or external clock
Power supply: AVDD1 − AVSS = 5 V, AVDD2 = IOVDD = 2.5 V
to 5 V
Split supply with AVDD1/AVSS at 2.5 V
ADC current: 8.4 mA
The digital filter allows simultaneous 50 Hz and 60 Hz rejection
at a 27.27 SPS output data rate. The user can switch between
different filter options according to the demands of each
channel in the application. The ADC automatically switches
through each selected channel. Further digital processing
functions include offset and gain calibration registers,
configurable on a per channel basis.
Temperature range: −40°C to +105°C
3- or 4-wire serial digital interface (Schmitt trigger on SCLK)
Serial port interface (SPI), QSPI, MICROWIRE, and DSP
compatible
The device operates with a 5 V AVDD1 supply, or with 2.5 V
AVDD1/AVSS, and 2 V to 5 V AVDD2 and IOVDD supplies.
The specified operating temperature range is −40°C to +105°C.
The AD7177-2 is available in a 24-lead TSSOP package.
APPLICATIONS
Process control: PLC/DCS modules
Temperature and pressure measurement
Medical and scientific multichannel instrumentation
Chromatography
FUNCTIONAL BLOCK DIAGRAM
AVDD1 AVDD2 REGCAPA
REF– REF+ REFOUT
IOVDD REGCAPD
RAIL-TO-RAIL
BUFFERED
PRECISION
REFERENCE
1.8V
LDO
1.8V
LDO
REFERENCE
CROSSPOINT
MULTIPLEXER
INPUT BUFFERS
INT
REF
AIN0
AIN1
AIN2
AIN3
AIN4
AVDD
RAIL-TO-RAIL
ANALOG INPUT
BUFFERS
CS
SCLK
SERIAL
DIGITAL
FILTER
INTERFACE
AND CONTROL
Σ-Δ ADC
DIN
DOUT/RDY
SYNC/ERROR
GPIO AND
MUX
I/O CONTROL
XTAL AND INTERNAL
CLOCK OSCILLATOR
CIRCUITRY
AVSS
AD7177-2
TEMPERATURE
SENSOR
AVSS
GPIO0 GPIO1
XTAL1 XTAL2/CLKIO
DGND
Figure 1.
Rev. B
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rightsof third parties that may result fromits use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks andregisteredtrademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2015–2016 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
AD7177-2* PRODUCT PAGE QUICK LINKS
Last Content Update: 06/27/2017
COMPARABLE PARTS
View a parametric search of comparable parts.
REFERENCE MATERIALS
Technical Articles
• Fundamental Principles Behind the Sigma-Delta ADC
Topology: Part 1
EVALUATION KITS
• Fundamental Principles Behind the Sigma-Delta ADC
Topology: Part 2
• AD7177-2 Evaluation Board
Tutorials
DOCUMENTATION
• MT-022: ADC Architectures III: Sigma-Delta ADC Basics
Data Sheet
• MT-023: ADC Architectures IV: Sigma-Delta ADC
Advanced Concepts and Applications
• AD7177-2: 32-Bit, 10 kSPS, Sigma-Delta ADC with 100 μs
Settling and True Rail-to-Rail Buffers Data Sheet
Technical Books
DESIGN RESOURCES
• AD7177-2 Material Declaration
• PCN-PDN Information
• The Data Conversion Handbook, 2005
User Guides
• UG-849: Evaluating the AD7177-2 32-Bit, 10 kSPS, Sigma-
Delta ADC with 100 µs Settling and Integrated Analog
Input Buffers
• Quality And Reliability
• Symbols and Footprints
SOFTWARE AND SYSTEMS REQUIREMENTS
• AD717x Microcontroller No-OS
DISCUSSIONS
View all AD7177-2 EngineerZone Discussions.
• AD717x Eval+ Software
SAMPLE AND BUY
TOOLS AND SIMULATIONS
• AD7177-2 Digital Filter Frequency Response Model
• AD7177-2 IBIS Model
Visit the product page to see pricing options.
TECHNICAL SUPPORT
Submit a technical question or find your regional support
number.
REFERENCE DESIGNS
• CN0292
DOCUMENT FEEDBACK
Submit feedback for this data sheet.
• CN0364
This page is dynamically generated by Analog Devices, Inc., and inserted into this data sheet. A dynamic change to the content on this page will not
trigger a change to either the revision number or the content of the product data sheet. This dynamic page may be frequently modified.
AD7177-2
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
CRC Calculation......................................................................... 42
Integrated Functions ...................................................................... 44
General-Purpose I/O ................................................................. 44
External Multiplexer Control ................................................... 44
Delay ............................................................................................ 44
24-Bit/32-Bit Conversions......................................................... 44
DOUT_RESET ........................................................................... 44
Synchronization.......................................................................... 44
Error Flags................................................................................... 45
DATA_STAT ............................................................................... 45
IOSTRENGTH ........................................................................... 46
Internal Temperature Sensor .................................................... 46
Grounding and Layout .................................................................. 47
Register Summary .......................................................................... 48
Register Details ............................................................................... 49
Communications Register......................................................... 49
Status Register............................................................................. 50
ADC Mode Register................................................................... 51
Interface Mode Register ............................................................ 52
Register Check............................................................................ 53
Data Register............................................................................... 53
GPIO Configuration Register................................................... 54
ID Register................................................................................... 55
Channel Register 0 ..................................................................... 55
Channel Register 1 to Channel Register 3 .............................. 56
Setup Configuration Register 0 ................................................ 57
Applications....................................................................................... 1
General Description......................................................................... 1
Functional Block Diagram .............................................................. 1
Revision History ............................................................................... 3
Specifications..................................................................................... 4
Timing Characteristics ................................................................ 7
Absolute Maximum Ratings............................................................ 9
Thermal Resistance ...................................................................... 9
ESD Caution.................................................................................. 9
Pin Configuration and Function Descriptions........................... 10
Typical Performance Characteristics ........................................... 12
Noise Performance and Resolution.............................................. 18
Getting Started................................................................................ 19
Power Supplies ............................................................................ 20
Digital Communication............................................................. 20
AD7177-2 Reset.......................................................................... 21
Configuration Overview ........................................................... 21
Circuit Description......................................................................... 27
Buffered Analog Input ............................................................... 27
Crosspoint Multiplexer.............................................................. 27
AD7177-2 Reference.................................................................. 28
Buffered Reference Input........................................................... 29
Clock Source ............................................................................... 29
Digital Filters................................................................................... 30
Sinc5 + Sinc1 Filter..................................................................... 30
Sinc3 Filter................................................................................... 30
Single Cycle Settling................................................................... 31
Enhanced 50 Hz and 60 Hz Rejection Filters ......................... 34
Operating Modes............................................................................ 37
Continuous Conversion Mode ................................................. 37
Continuous Read Mode............................................................. 38
Single Conversion Mode ........................................................... 39
Standby and Power-Down Modes............................................ 40
Calibration................................................................................... 40
Digital Interface .............................................................................. 41
Checksum Protection................................................................. 41
Setup Configuration Register 1 to Setup Configuration
Register 3 ..................................................................................... 57
Filter Configuration Register 0................................................. 58
Filter Configuration Register 1 to Filter Configuration
Register 3 ..................................................................................... 59
Offset Register 0 ......................................................................... 59
Offset Register 1 to Offset Register 3....................................... 59
Gain Register 0............................................................................ 59
Gain Register 1 to Gain Register 3........................................... 59
Outline Dimensions....................................................................... 60
Ordering Guide .......................................................................... 60
Rev. B | Page 2 of 60
Data Sheet
AD7177-2
REVISION HISTORY
3/16—Rev. A to Rev. B
Changes to Power Supplies Section ..............................................20
9/15—Rev. 0 to Rev. A
Changes to Figure 12 and Figure 13 .............................................13
Changes to Table 37 ........................................................................57
Change to Table 40 and Table 42...................................................58
3/15—Revision 0: Initial Version
Rev. B | Page 3 of 60
AD7177-2
Data Sheet
SPECIFICATIONS
AVDD1 = 4.5 V to 5.5 V, AVDD2 = 2 V to 5.5 V, IOVDD = 2 V to 5.5 V, AVSS = DGND = 0 V, REF+ = 2.5 V, REF− = AVSS,
internal master clock (MCLK) = 16 MHz, TA = TMIN to TMAX (−40°C to +105°C), unless otherwise noted.
Table 1.
Parameter
Test Conditions/Comments
Min
Typ
Max
Unit
ADC SPEED AND PERFORMANCE
Output Data Rate (ODR)
No Missing Codes1
Resolution
Noise
FIR Filter Rejection
ACCURACY
5
32
10,000
SPS
Bits
See Table 19 to Table 23
See Table 19 to Table 23
See Table 23
Integral Nonlinearity (INL)
All input buffers disabled
All input buffers enabled
Internal short
Internal short
All input buffers disabled
All input buffers enabled
1
3.5
7.8
ppm of FSR
ppm of FSR
µV
3.5
40
80
45
2.5
0.4
Offset Error2
Offset Drift
Gain Error2
nV/°C
100
40
0.75
ppm of FSR
ppm of FSR
ppm/°C
Gain Drift
REJECTION
Power Supply Rejection
Common-Mode Rejection
At DC
AVDD1, AVDD2, VIN = 1 V
VIN = 0.1 V
95
dB
95
120
dB
dB
At 50 Hz, 60 Hz1
20 Hz output data rate (post filter),
50 Hz 1 Hz and 60 Hz 1 Hz
50 Hz 1 Hz and 60 Hz 1 Hz
Normal Mode Rejection1
Internal clock, 20 SPS ODR (postfilter)
External clock, 20 SPS ODR (postfilter)
71
85
90
90
dB
dB
ANALOG INPUTS
Differential Input Range
Absolute Voltage Limits1
Input Buffers Disabled
Input Buffers Enabled
Analog Input Current
Input Buffers Disabled
Input Current
VREF = (REF+) − (REF−)
VREF
V
AVSS − 0.05
AVSS
AVDD1 + 0.05
AVDD1
V
V
48
0.75
4
µA/V
nA/V/°C
nA/V/°C
Input Current Drift
External clock
Internal clock ( 2.5% clock)
Input Buffers Enabled
Input Current
Input Current Drift
30
75
1
nA
AVDD1 − 0.2 V to AVSS + 0.2 V
AVDD1 to AVSS
1 kHz input
pA/°C
nA/°C
dB
Crosstalk
−120
INTERNAL REFERENCE
Output Voltage
100 nF external capacitor to AVSS
REFOUT, with respect to AVSS
REFOUT, TA = 25°C
2.5
V
Initial Accuracy3
−0.12
−10
+0.12
% of V
Temperature Coefficient1
0°C to 105°C
−40°C to +105°C
Reference Load Current, ILOAD
Power Supply Rejection
Load Regulation
2
3
5
10
+10
ppm/°C
ppm/°C
mA
dB
ppm/mA
AVDD1, AVDD2 (line regulation)
∆VOUT/∆ILOAD
90
32
Rev. B | Page 4 of 60
Data Sheet
AD7177-2
Parameter
Test Conditions/Comments
eN, 0.1 Hz to 10 Hz, 2.5 V reference
eN, 1 kHz, 2.5 V reference
Min
Typ
4.5
215
200
25
Max
Unit
µV rms
nV/√Hz
µs
Voltage Noise
Voltage Noise Density
Turn-On Settling Time
Short-Circuit Current, ISC
EXTERNAL REFERENCE INPUTS
Differential Input Range
Absolute Voltage Limits1
Input Buffers Disabled
Input Buffers Enabled
REF+/REF− Input Current
Input Buffers Disabled
Input Current
100 nF REFOUT capacitor
mA
VREF = (REF+) − (REF−)
1
2.5
AVDD1
V
AVSS − 0.05
AVSS
AVDD1 + 0.05
AVDD1
V
V
72
1.2
6
µA/V
nA/V/°C
nA/V/°C
Input Current Drift
External clock
Internal clock
Input Buffers Enabled
Input Current
800
nA
Input Current Drift
Normal Mode Rejection1
Common-Mode Rejection
TEMPERATURE SENSOR
Accuracy
1.25
nA/°C
See the Rejection parameter
After user calibration at 25°C
95
dB
2
°C
Sensitivity
470
µV/K
BURNOUT CURRENTS
Source/Sink Current
Analog input buffers must be enabled
With respect to AVSS
10
µA
GENERAL-PURPOSE I/O
(GPIO0, GPIO1)
Input Mode Leakage Current1
Floating State Output
Capacitance
Output High Voltage, VOH
Output Low Voltage, VOL
Input High Voltage, VIH
Input Low Voltage, VIL
−10
+10
µA
pF
5
1
ISOURCE = 200 µA
ISINK = 800 µA
AVSS + 4
AVSS + 3
V
V
V
V
1
AVSS + 0.4
AVSS + 0.7
1
1
CLOCK
Internal Clock
Frequency
Accuracy
16
50
MHz
%
%
V
V
−2.5%
+2.5%
0.4
Duty Cycle
Output Low Voltage, VOL
Output High Voltage, VOH
Crystal
0.8 × IOVDD
14
Frequency
16
10
16
50
16.384
MHz
µs
MHz
%
Start-Up Time
External Clock (CLKIO)
Duty Cycle1
16.384
70
30
Rev. B | Page 5 of 60
AD7177-2
Data Sheet
Parameter
Test Conditions/Comments
Min
Typ
Max
Unit
LOGIC INPUTS
Input High Voltage, VINH
1
2 V ≤ IOVDD < 2.3 V
2.3 V ≤ IOVDD ≤ 5.5 V
2 V ≤ IOVDD < 2.3 V
2.3 V ≤ IOVDD ≤ 5.5 V
IOVDD ≥ 2.7 V
0.65 × IOVDD
0.7 × IOVDD
V
V
V
V
V
1
Input Low Voltage, VINL
0.35 × IOVDD
0.7
0.25
0.2
+10
Hysteresis1
0.08
0.04
−10
IOVDD < 2.7 V
V
µA
Leakage Current
LOGIC OUTPUT (DOUT/RDY)
1
Output High Voltage, VOH
IOVDD ≥ 4.5 V, ISOURCE = 1 mA
2.7 V ≤ IOVDD < 4.5 V, ISOURCE = 500 µA
IOVDD < 2.7 V, ISOURCE = 200 µA
IOVDD ≥ 4.5 V, ISINK = 2 mA
2.7 V ≤ IOVDD < 4.5 V, ISINK = 1 mA
IOVDD < 2.7 V, ISINK = 400 µA
Floating state
0.8 × IOVDD
0.8 × IOVDD
0.8 × IOVDD
V
V
V
V
V
V
µA
pF
1
Output Low Voltage, VOL
0.4
0.4
0.4
+10
Leakage Current
Output Capacitance
SYSTEM CALIBRATION1
Full-Scale (FS) Calibration Limit
Zero-Scale Calibration Limit
Input Span
−10
Floating state
10
1.05 × FS
2.1 × FS
V
V
V
−1.05 × FS
0.8 × FS
POWER REQUIREMENTS
Power Supply Voltage
AVDD1 to AVSS
4.5
2
−2.75
2
5
5.5
5.5
0
5.5
6.35
V
V
V
V
V
AVDD2 to AVSS
AVSS to DGND
IOVDD to DGND
IOVDD to AVSS
2.5 to 5
2.5 to 5
For AVSS < DGND
POWER SUPPLY CURRENTS4
All outputs unloaded, digital inputs
connected to IOVDD or DGND
Full Operating Mode
AVDD1 Current
Analog input and reference input
buffers disabled, external reference
Analog input and reference input
buffers disabled, internal reference
Analog input and reference input
buffers enabled, external reference
1.4
1.75
13
1.65
2
mA
mA
mA
16
Each buffer: AIN+, AIN−, REF+, REF−
External reference
Internal reference
External clock
Internal clock
External crystal
Internal reference off, total current
consumption
Internal reference on, total current
consumption
Full power-down (including LDO and
internal reference)
2.9
4.5
4.75
2.5
2.75
3
mA
mA
mA
mA
mA
mA
µA
AVDD2 Current
IOVDD Current
5
5.2
2.8
3.1
Standby Mode (LDO On)
Power-Down Mode
25
425
5
µA
µA
10
Rev. B | Page 6 of 60
Data Sheet
AD7177-2
Parameter
Test Conditions/Comments
Min
Typ
Max
Unit
POWER DISSIPATION4
Full Operating Mode
All buffers disabled, external clock and
reference, AVDD2 = 2 V, IOVDD = 2 V
All buffers disabled, external clock and
reference, all supplies = 5 V
All buffers disabled, external clock and
reference, all supplies = 5.5 V
All buffers enabled, internal clock and
reference, AVDD2 = 2 V, IOVDD = 2 V
All buffers enabled, internal clock and
reference, all supplies = 5 V
All buffers enabled, internal clock and
reference, all supplies = 5.5 V
Internal reference off, all supplies = 5 V
Internal reference on, all supplies = 5 V
Full power-down, all supplies = 5 V
21
42
mW
mW
mW
mW
mW
mW
52
82
105
136
50
Standby Mode
125
2.2
25
µW
mW
µW
Power-Down Mode
1 This specification is not production tested but is supported by characterization data at initial product release.
2 Following a system or internal zero-scale calibration, the offset error is in the order of the noise for the programmed output data rate selected. A system full-scale
calibration reduces the gain error to the order of the noise for the programmed output data rate.
3 This specification includes moisture sensitivity level (MSL) preconditioning effects.
4 This specification is with no load on the REFOUT and digital output pins.
TIMING CHARACTERISTICS
IOVDD = 2 V to 5.5 V, DGND = 0 V, Input Logic 0 = 0 V, Input Logic 1 = IOVDD, CLOAD = 20 pF, unless otherwise noted.
Table 2.
Parameter
Limit at TMIN, TMAX
Unit
Description1, 2
SCLK
t3
t4
25
25
ns min
ns min
SCLK high pulse width
SCLK low pulse width
READ OPERATION
t1
0
ns min
ns max
ns max
ns min
ns max
ns max
ns min
ns max
ns min
ns min
CS falling edge to DOUT/RDY active time
IOVDD = 4.75 V to 5.5 V
IOVDD = 2 V to 3.6 V
SCLK active edge to data valid delay4
IOVDD = 4.75 V to 5.5 V
IOVDD = 2 V to 3.6 V
Bus relinquish time after CS inactive edge
15
40
0
12.5
25
2.5
20
0
3
t2
5
t5
t6
t7
SCLK inactive edge to CS inactive edge
10
SCLK inactive edge to DOUT/RDY high/low
WRITE OPERATION
t8
0
8
8
5
ns min
ns min
ns min
ns min
CS falling edge to SCLK active edge setup time4
Data valid to SCLK edge setup time
Data valid to SCLK edge hold time
CS rising edge to SCLK edge hold time
t9
t10
t11
1 Sample tested during initial release to ensure compliance.
2 See Figure 2 and Figure 3.
3 This parameter is defined as the time required for the output to cross the VOL or VOH limits.
4 The SCLK active edge is the falling edge of SCLK.
5
RDY
while DOUT/
DOUT/
returns high after a read of the data register. In single conversion mode and continuous conversion mode, the same data can be read again, if required,
RDY
is high, although care must be taken to ensure that subsequent reads do not occur close to the next output update. If the continuous read feature is
enabled, the digital word can be read only once.
Rev. B | Page 7 of 60
AD7177-2
Data Sheet
Timing Diagrams
CS (I)
t6
t1
t5
MSB
LSB
DOUT/RDY (O)
t7
t2
t3
SCLK (I)
t4
I = INPUT, O = OUTPUT
Figure 2. Read Cycle Timing Diagram
CS (I)
t11
t8
SCLK (I)
DIN (I)
t9
t10
MSB
LSB
I = INPUT, O = OUTPUT
Figure 3. Write Cycle Timing Diagram
Rev. B | Page 8 of 60
Data Sheet
AD7177-2
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
THERMAL RESISTANCE
θJA is specified for a device soldered on a JEDEC test board for
surface-mount packages.
Table 3.
Parameter
Rating
AVDD1, AVDD2 to AVSS
AVDD1 to DGND
IOVDD to DGND
IOVDD to AVSS
−0.3 V to +6.5 V
−0.3 V to +6.5 V
−0.3 V to +6.5 V
−0.3 V to +7.5 V
−3.25 V to +0.3 V
−0.3 V to AVDD1 + 0.3 V
−0.3 V to AVDD1 + 0.3 V
−0.3 V to IOVDD + 0.3 V
−0.3 V to IOVDD + 0.3 V
10 mA
−40°C to +105°C
−65°C to +150°C
150°C
260°C
4 kV
Table 4. Thermal Resistance
Package Type
θJA
Unit
24-Lead TSSOP
JEDEC 1-Layer Board
JEDEC 2-Layer Board
149
81
°C/W
°C/W
AVSS to DGND
Analog Input Voltage to AVSS
Reference Input Voltage to AVSS
Digital Input Voltage to DGND
Digital Output Voltage to DGND
Analog Input/Digital Input Current
Operating Temperature Range
Storage Temperature Range
Maximum Junction Temperature
Lead Soldering, Reflow Temperature
ESD Rating (Human Body Model)
ESD CAUTION
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Rev. B | Page 9 of 60
AD7177-2
Data Sheet
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
24
23
22
21
20
19
18
17
16
15
14
13
1
2
3
4
5
6
7
8
AIN4
REF–
AIN3
AIN2
REF+
AIN1
REFOUT
REGCAPA
AVSS
AIN0
GPIO1
GPIO0
REGCAPD
DGND
IOVDD
SYNC/ERROR
CS
AD7177-2
TOP VIEW
(Not to Scale)
AVDD1
AVDD2
9
XTAL1
10
11
12
XTAL2/CLKIO
DOUT/RDY
DIN
SCLK
Figure 4. Pin Configuration
Table 5. Pin Function Descriptions1
Pin No.
Mnemonic
Type 2
AI
AI
AI
Description
1
2
3
AIN4
REF−
REF+
Analog Input 4. This pin is electable through the crosspoint multiplexer.
Reference Input Negative Terminal. REF− can span from AVSS to AVDD1 − 1 V.
Reference Input Positive Terminal. An external reference can be applied between REF+ and REF−. REF+
can span from AVSS + 1 V to AVDD1. The device functions with a reference magnitude from 1 V to AVDD1.
4
5
REFOUT
REGCAPA
AO
AO
Buffered Output of Internal Reference. The output is 2.5 V with respect to AVSS.
Analog Low Dropout (LDO) Regulator Output. Decouple this pin to AVSS using a 1 µF and a 0.1 µF
capacitor.
6
7
AVSS
AVDD1
P
P
Negative Analog Supply. This supply ranges from −2.75 V to 0 V and is nominally set to 0 V.
Analog Supply Voltage 1. This voltage is 5 V 10% with respect to AVSS. AVDD1 − AVSS can be a single
5 V supply or a 2.5 V split supply.
8
9
AVDD2
XTAL1
P
AI
Analog Supply Voltage 2. This voltage ranges from 2 V to 5 V with respect to AVSS.
Input 1 for Crystal.
10
XTAL2/CLKIO
AI/DI
Input 2 for Crystal/Clock Input or Output. The functionality of this pin is based on the CLOCKSEL bits in
the ADCMODE register. There are four options available for selecting the MCLK source:
Internal oscillator: no output.
Internal oscillator: output to XTAL2/CLKIO. Operates at IOVDD logic level.
External clock: input to XTAL2/CLKIO. Input must be at IOVDD logic level.
External crystal: connected between XTAL1 and XTAL2/CLKIO.
11
DOUT/RDY
DO
Serial Data Output/Data Ready Output. DOUT/RDY is a dual purpose pin. It functions as a serial data
output pin to access the output shift register of the ADC. The output shift register can contain data
from any of the on-chip data or control registers. The data-word/control word information is placed on
the DOUT/RDY pin on the SCLK falling edge and is valid on the SCLK rising edge. When CS is high, the
DOUT/RDY output is three-stated. When CS is low, DOUT/RDY operates as a data ready pin, going low
to indicate the completion of a conversion. If the data is not read after the conversion, the pin goes
high before the next update occurs. The DOUT/RDY falling edge can be used as an interrupt to a
processor, indicating that valid data is available.
12
DIN
DI
Serial Data Input to the Input Shift Register on the ADC. Data in this shift register is transferred to the
control registers in the ADC, with the register address (RA) bits of the communications register
identifying the appropriate register. Data is clocked in on the rising edge of SCLK.
13
14
SCLK
CS
DI
DI
Serial Clock Input. This serial clock input is for data transfers to and from the ADC. The SCLK pin has a
Schmitt triggered input, making the interface suitable for opto-isolated applications.
Chip Select Input. This pin is an active low logic input used to select the ADC. CS can be used to select
the ADC in systems with more than one device on the serial bus. CS can be hardwired low, allowing the
ADC to operate in 3-wire mode with SCLK, DIN, and DOUT used to interface with the device. When CS
is high, the DOUT/RDY output is three-stated.
Rev. B | Page 10 of 60
Data Sheet
AD7177-2
Pin No.
Mnemonic
SYNC/ERROR
Type 2
Description
15
DI/O
Synchronization Input/Error Input or Output. This pin can be switched between a logic input and a
logic output in the GPIOCON register. When the synchronization input (SYNC) is enabled, this pin
allows synchronization of the digital filters and analog modulators when using multiple AD7177-2
devices. For more information, see the Synchronization section. When the synchronization input is
disabled, this pin can be used in one of three modes:
Active low error input mode: this mode sets the ADC_ERROR bit in the status register.
Active low, open-drain error output mode: the status register error bits are mapped to the ERROR
output. The SYNC/ERROR pins of multiple devices can be wired together to a common pull-up resistor
so that an error on any device can be observed.
General-purpose output mode: the status of the pin is controlled by the ERR_DAT bit in the GPIOCON
register. The pin is referenced between IOVDD and DGND, as opposed to the AVDD1 and AVSS levels
used by the GPIOx pins. The pin has an active pull-up circuit in this case.
16
IOVDD
P
Digital I/O Supply Voltage. The IOVDD voltage ranges from 2 V to 5.5 V. IOVDD is independent of
AVDD2. For example, IOVDD can be operated at 3 V when AVDD2 equals 5 V, or vice versa. If AVSS is
set to −2.5 V, the voltage on IOVDD must not exceed 3.6 V.
17
18
DGND
REGCAPD
P
AO
Digital Ground.
Digital LDO Regulator Output. This pin is for decoupling purposes only. Decouple this pin to DGND
using a 1 µF and a 0.1 µF capacitor.
19
20
21
22
23
24
GPIO0
GPIO1
AIN0
AIN1
AIN2
AIN3
DI/O
DI/O
AI
AI
AI
General-Purpose Input/Output 0. The pin is referenced between AVDD1 and AVSS levels.
General-Purpose Input/Output 1. The pin is referenced between AVDD1 and AVSS levels.
Analog Input 0. This pin is selectable through the crosspoint multiplexer.
Analog Input 1. This pin is selectable through the crosspoint multiplexer.
Analog Input 2. This pin is selectable through the crosspoint multiplexer.
Analog Input 3. This pin is selectable through the crosspoint multiplexer.
AI
1 Note that, throughout this data sheet, the dual function pin names are referenced by the relevant function only.
2 AI is analog input, AO is analog output, P is power supply, DI is digital input, DO is digital output, and DI/O is bidirectional digital input/output.
Rev. B | Page 11 of 60
AD7177-2
Data Sheet
TYPICAL PERFORMANCE CHARACTERISTICS
AVDD1 = 5 V, AVDD2 = 5 V, IOVDD = 3.3 V, TA = 25°C, unless otherwise noted.
2147454000
2147453950
2147453900
2147453850
2147453800
2147453750
2147453700
160
140
120
100
80
60
40
20
0
SAMPLE NUMBER
ADC CODE
Figure 8. Histogram (Analog Input Buffers Disabled, VREF = 5 V,
Output Data Rate = 5 SPS, 32-Bit Data Output)
Figure 5. Noise (Analog Input Buffers Disabled, VREF = 5 V,
Output Data Rate = 5 SPS, 32-Bit Data Output)
140
120
100
80
2147458000
2147457000
2147456000
2147455000
2147454000
2147453000
2147452000
2147451000
2147450000
2147449000
2147448000
2147447000
60
40
20
0
SAMPLE NUMBER
ADC CODE
Figure 6. Noise (Analog Input Buffers Disabled, VREF = 5 V,
Output Data Rate = 10 kSPS, 32-Bit Data Output)
Figure 9. Histogram (Analog Input Buffers Disabled, VREF = 5 V,
Output Data Rate = 10 kSPS, 32-Bit Data Output)
160
140
120
100
80
2147456250
2147456200
2147456150
2147456100
2147456050
2147456000
2147455950
2147455900
2147455850
60
40
20
0
SAMPLE NUMBER
ADC CODE
Figure 10. Histogram (Analog Input Buffers Enabled, VREF = 5 V,
Output Data Rate = 5 SPS)
Figure 7. Noise (Analog Input Buffers Enabled, VREF = 5 V,
Output Data Rate = 5 SPS)
Rev. B | Page 12 of 60
Data Sheet
AD7177-2
2147462000
2147460000
2147458000
2147456000
2147454000
2147452000
2147450000
2147448000
160
140
120
100
80
60
40
20
0
SAMPLE NUMBER
ADC CODE
Figure 11. Noise (Analog Input Buffers Enabled, VREF = 5 V,
Output Data Rate = 10 kSPS)
Figure 14. Histogram (Analog Input Buffers Enabled, VREF = 5 V,
Output Data Rate = 10 kSPS)
16800000
10
CONTINUOUS CONVERSION—REFERENCE DISABLED
STANDBY—REFERENCE DISABLED
9
8
7
6
5
4
3
2
1
0
STANDBY—REFERENCE ENABLED
16780000
16760000
16740000
16720000
16700000
16680000
16660000
ANALOG INPUT BUFFERS ON
ANALOG INPUT BUFFERS OFF
0
1
2
3
4
5
1
10
100
1k
10k
INPUT COMMON-MODE VOLTAGE (V)
SAMPLE NUMBER
Figure 12. Noise vs. Input Common-Mode Voltage, Analog Input Buffers On
and Off
Figure 15. Internal Reference Settling Time
0
–20
10
9
8
7
–40
6
5
–60
4
ANALOG INPUT BUFFERS ON
3
–80
ANALOG INPUT BUFFERS OFF
2
1
0
–100
–120
1
0
2
4
6
8
10
12
14
16
10
100
1k
10k
100k
1M
FREQUENCY (MHz)
V
FREQUENCY (Hz)
IN
Figure 13. Noise vs. External Master Clock Frequency,
Analog Input Buffers On and Off
Figure 16. Common-Mode Rejection Ratio (CMRR) vs. VIN Frequency
(VIN = 0.1 V)
Rev. B | Page 13 of 60
AD7177-2
Data Sheet
30
25
20
15
10
5
–80
–90
–100
–110
–120
–130
–140
–150
–160
–170
0
–180
10
2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
INL ERROR (ppm)
20
30
V
40
50
60
70
FREQUENCY (Hz)
IN
Figure 17. Common-Mode Rejection Ratio (CMRR) vs. VIN Frequency
(VIN = 0.1 V, 10 Hz to 70 Hz, Output Data Rate = 20 SPS, Enhanced Filter)
Figure 20. Integral Nonlinearity (INL) Distribution Histogram (Differential
Input, All Input Buffers Enabled, VREF = 2.5 V External, 100 Units)
–60
30
25
20
15
10
5
AVDD1—EXTERNAL 2.5V REFERENCE
AVDD1—INTERNAL 2.5V REFERENCE
–70
–80
–90
–100
–110
–120
–130
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
1
10
100
1k
10k
100k
1M
10M
100M
INL ERROR (ppm)
V
FREQUENCY (Hz)
IN
Figure 21. Integral Nonlinearity (INL) Distribution Histogram (Differential
Input, All Input Buffers Disabled, VREF = 2.5 V External, 100 Units)
Figure 18. Power Supply Rejection Ratio (PSRR) vs. VIN Frequency
30
25
20
15
10
5
20
INTERNAL 2.5V REF,
ANALOG INPUT BUFFERS OFF
INTERNAL 2.5V REF,
ANALOG INPUT BUFFERS ON
EXTERNAL 2.5V REF,
ANALOG INPUT BUFFERS OFF
EXTERNAL 2.5V REF,
ANALOG INPUT BUFFERS ON
EXTERNAL 5V REF,
ANALOG INPUT BUFFERS OFF
EXTERNAL 5V REF,
ANALOG INPUT BUFFERS ON
15
10
5
0
–5
–10
–15
–20
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
–5
–4
–3
–2
–1
0
1
2
3
4
5
INL ERROR (ppm)
V
(V)
IN
Figure 22. Integral Nonlinearity (INL) Distribution Histogram (All Input
Buffers Enabled, Differential Input, VREF = 5 V External, 100 Units)
Figure 19. Integral Nonlinearity (INL) vs. VIN
(Differential Input)
Rev. B | Page 14 of 60
Data Sheet
AD7177-2
16400000
16300000
16200000
16100000
16000000
15900000
15800000
15700000
15600000
30
25
20
15
10
5
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
–40
–20
0
20
40
60
80
100
INL ERROR (ppm)
TEMPERATURE (°C)
Figure 23. Integral Nonlinearity (INL) Distribution Histogram (All Input
Buffers Disabled, Differential Input, VREF = 5 V External, 100 Units)
Figure 26. Internal Oscillator Frequency vs. Temperature
0.0010
5.0
BUFFER DISABLED
BUFFER ENABLED
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
0.0005
0
–0.0005
–0.0010
–40
–20
0
20
40
60
80
100
–40
–20
0
20
40
60
80
100
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 24. Integral Nonlinearity (INL) vs. Temperature
(Differential Input, VREF = 2.5 V External)
Figure 27. Absolute Reference Error vs. Temperature
50
45
40
35
30
25
20
15
10
5
50
45
40
35
30
25
20
15
10
5
0
0
15.98 15.99 16.00 16.01 16.02 16.03 16.04 16.05
FREQUENCY (MHz)
–40 –30 –20 –10
0
10 20 30 40 50 60 70 80 90
OFFSET ERROR (µV)
Figure 25. Internal Oscillator Frequency/Accuracy Distribution Histogram
(100 Units)
Figure 28. Offset Error Distribution Histogram (Internal Short, 248 Units)
Rev. B | Page 15 of 60
AD7177-2
Data Sheet
35
30
25
20
15
10
5
25
20
15
10
5
0
0
OFFSET DRIFT ERROR (nV/°C)
GAIN ERROR DRIFT (ppm/FSR)
Figure 29. Offset Error Drift Distribution Histogram (Internal Short, 248 Units)
Figure 32. Gain Error Drift Distribution Histogram
(All Input Buffers Enabled, 100 Units)
40
35
30
25
20
15
10
5
40
35
30
25
20
15
10
5
0
0
–4
–3
–2
–1
0
1
2
3
4
0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55
GAIN ERROR DRIFT (ppm/FSR)
GAIN ERROR (ppm/FSR)
Figure 30. Gain Error Distribution Histogram (All Input Buffers Enabled, 100 Units)
Figure 33. Gain Error Drift Distribution Histogram
(All Input Buffers Disabled, 100 Units)
0.025
0.020
0.015
0.010
0.005
0
30
25
20
15
10
5
BUFFERS DISABLED
BUFFERS ENABLED
0
–40
–20
0
20
40
60
80
100
34
35
36
37
38
39
40
41
42
43
GAIN ERROR (ppm/FSR)
TEMPERATURE (°C)
Figure 34. Supply Current vs. Temperature
(Continuous Conversion Mode)
Figure 31. Gain Error Distribution Histogram
(All Input Buffers Disabled, 100 Units)
Rev. B | Page 16 of 60
Data Sheet
AD7177-2
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
100
80
–40°C, AIN+
–40°C, AIN–
+25°C, AIN+
+25°C, AIN–
+105°C, AIN+
+105°C, AIN–
60
40
20
0
–20
–40
–60
–80
–100
–40
–20
0
20
40
60
80
100
–5
–4
–3
–2
–1
0
1
2
3
4
5
TEMPERATURE (°C)
INPUT VOLTAGE (V)
Figure 35. Supply Current vs. Temperature (Power-Down Mode)
Figure 38. Analog Input Current vs. Input Voltage
(VCM = 2.5 V, All Input Buffers Enabled)
18
16
14
12
10
8
100
AIN+ = AVDD1 – 0.2V
AIN– = AVSS + 0.2V
AIN+ = AVDD1
80
60
AIN– = AVSS
40
20
0
–20
–40
–60
–80
–100
6
4
2
0
–40
–20
0
20
40
60
80
100
–1.2 –1.0 –0.8 –0.6 –0.4 –0.2
0
0.2 0.4 0.6 0.8 1.0
TEMPERATURE DELTA (°C)
TEMPERATURE (°C)
Figure 36. Temperature Sensor Distribution Histogram
(Uncalibrated, 100 Units)
Figure 39. Analog Input Current vs. Temperature
(All Input Buffers Enabled)
35
30
25
20
15
10
5
0
9.60 9.65 9.70 9.75 9.80 9.85 9.90 9.95 10.00 10.05 10.10
CURRENT (µA)
Figure 37. Burnout Current Distribution Histogram
(100 Units)
Rev. B | Page 17 of 60
AD7177-2
Data Sheet
NOISE PERFORMANCE AND RESOLUTION
Table 6 and Table 7 show the rms noise, peak-to-peak noise,
effective resolution, and the noise free (peak-to-peak)
resolution of the AD7177-2 for various output data rates and
filters. The numbers given are for the bipolar input range with
an external 5 V reference. These numbers are typical and are
generated with a differential input voltage of 0 V when the ADC
is continuously converting on a single channel. It is important
to note that the peak-to-peak resolution is calculated based on
the peak-to-peak noise. The peak-to-peak resolution represents
the resolution for which there is no code flicker.
Table 6. RMS Noise and Peak-to-Peak Resolution vs. Output Data Rate Using a Sinc5 + Sinc1 Filter (Default)1
Output Data Rate (SPS)
RMS Noise (µV rms)
Effective Resolution (Bits)
Peak-to-Peak Noise (µV p-p) Peak-to-Peak Resolution (Bits)
Input Buffers Disabled
10,000
1000
59.92
49.96
16.66
5
2.5
21.9
23.6
25.8
26
26.7
27.3
18.3
5.2
1.1
0.95
0.45
0.34
19.1
20.9
23.1
23.3
24.1
24.6
0.77
0.19
0.18
0.1
0.07
Input Buffers Enabled
10,000
1000
59.98
49.96
16.66
5
3
21.7
23.4
25.7
26
26.6
26.7
23
18.7
20.7
23.0
23.3
23.9
24.6
0.92
0.23
0.2
0.13
0.07
5.7
1.2
1
0.66
0.32
1 Selected rates only, 1000 samples.
Table 7. RMS Noise and Peak-to-Peak Resolution vs. Output Data Rate Using a Sinc3 Filter1
Output Data Rate (SPS)
RMS Noise (µV rms)
Effective Resolution (Bits)
Peak-to-Peak Noise (µV p-p) Peak-to-Peak Resolution (Bits)
Input Buffers Disabled
10,000
1000
60
50
16.66
5
1.8
22.4
24
26.3
26.5
27
14
3.9
0.8
0.7
0.37
0.21
19.4
21.3
23.6
23.8
24.3
24.8
0.56
0.13
0.13
0.07
0.05
27.5
Input Buffers Enabled
10,000
1000
60
50
16.66
5
2.1
22.2
23.7
25.8
26.2
26.8
27.2
24
16
4.5
1.1
0.83
0.6
19.3
21.1
23.1
23.5
24.1
24.5
24
0.71
0.17
0.15
0.12
0.08
0.08
0.35
0.35
5
1 Selected rates only, 1000 samples.
Rev. B | Page 18 of 60
Data Sheet
AD7177-2
GETTING STARTED
The AD7177-2 offers the user a fast settling, high resolution,
multiplexed ADC with high levels of configurability. The
AD7177-2 includes the following features:
The AD7177-2 includes a precision 2.5 V low drift ( 2 ppm/°C)
band gap internal reference. This reference can be used for the
ADC conversions, reducing the external component count.
Alternatively, the reference can be output to the REFOUT pin to
be used as a low noise biasing voltage for external circuitry. An
example of this is using the REFOUT signal to set the input
common mode for an external amplifier.
•
•
Two fully differential or four single-ended analog inputs.
A crosspoint multiplexer selects any analog input combina-
tion as the input signals to be converted, routing them to
the modulator positive or negative input.
The AD7177-2 includes two separate linear regulator blocks for
both the analog and digital circuitry. The analog LDO regulates
the AVDD2 supply to 1.8 V, supplying the ADC core. The user
can tie the AVDD1 and AVDD2 supplies together for an easy
connection. If there is already a clean analog supply rail in the
system in the range of 2 V (minimum) to 5.5 V (maximum), the
user can also choose to connect this to the AVDD2 input,
allowing lower power dissipation.
•
•
True rail-to-rail buffered analog and reference inputs.
Fully differential input or single-ended input relative to any
analog input.
Per channel configurability—up to four different setups
can be defined. A separate setup can be mapped to each of
the channels. Each setup allows the user to configure
whether the buffers are enabled or disabled, gain and offset
correction, filter type, output data rate, and reference
source selection (internal/external).
•
GENERAL-PURPOSE I/O 0 AND
GENERAL-PURPOSE I/O 1
OUTPUT HIGH = AVDDx
OUTPUT LOW = AVSS
GPIO0
GPIO1
16MHz
20
19
CX2
CX1
GPIO0
GPIO1
OPTIONAL EXTERNAL
CRYSTAL CIRCUITRY
CAPACITORS
9
XTAL1
21
AIN0
10
XTAL2/CLKIO
CLKIN
OPTIONAL
EXTERNAL
CLOCK
INPUT
DOUT/RDY 11
DOUT/RDY
DIN
22
23
AIN1
AIN2
12
DIN
13
SCLK
CS
SCLK
14
15
CS
SYNC/ERROR
SYNC/ERROR
IOVDD
24
1
AIN3
AIN4
AD7177-2
16
17
IOVDD
DGND
0.1µF
1
3
V
IN
TP
NC
REGCAPD 18
2
4
7
6
V
NC
IN
0.1µF
1µF
AVDD1
4.7µF
0.1µF
ADR445
AVDD1
AVDD2
7
8
5
0.1µF
3
GND
V
REF+
REF–
OUT
AVDD2
0.1µF
4.7µF
0.1µF
0.1µF
TRIM
5
TP
8
2
4
0.1µF
REFOUT
REGCAPA
2.5V REFERENCE
OUTPUT
0.1µF
1µF
AVSS
6
0.1µF
Figure 40. Typical Connection Diagram
Rev. B | Page 19 of 60
AD7177-2
Data Sheet
The linear regulator for the digital IOVDD supply performs a
similar function, regulating the input voltage applied at the
IOVDD pin to 1.8 V for the internal digital filtering. The serial
interface signals always operate from the IOVDD supply seen at
the pin. This means that if 3.3 V is applied to the IOVDD pin,
the interface logic inputs and outputs operate at this level.
DRIVE EDGE
SAMPLE EDGE
Figure 41. SPI Mode 3 SCLK Edges
The AD7177-2 can be used across a wide variety of applications,
providing high resolution and accuracy. A sample of these
scenarios is as follows:
Accessing the ADC Register Map
The communications register controls access to the full register
map of the ADC. This register is an 8-bit write only register. On
power-up or after a reset, the digital interface defaults to a state
where it is expecting a write to the communications register;
therefore, all communication begins by writing to the
communications register.
•
•
•
•
Fast scanning of analog input channels using the internal
multiplexer
Fast scanning of analog input channels using an external
multiplexer with automatic control from the GPIOs.
High resolution at lower speeds in either channel scanning
or ADC per channel applications
Single ADC per channel. The fast low latency output allows
further application specific filtering in an external micro-
controller, DSP, or FPGA
The data written to the communications register determines
which register is being accessed and if the next operation is a
read or write. The register address bits (RA[5:0]) determine the
specific register to which the read or write operation applies.
When the read or write operation to the selected register is
complete, the interface returns to its default state, where it
expects a write operation to the communications register.
POWER SUPPLIES
The AD7177-2 has three independent power supplies: AVDD1,
AVDD2, and IOVDD.
Figure 42 and Figure 43 illustrate writing to and reading from a
register by first writing the 8-bit command to the communications
register, followed by the data for that register.
AVDD1 powers the crosspoint multiplexer and integrated analog
and reference input buffers. AVDD1 is referenced to AVSS, and
AVDD1 − AVSS = 5 V only. AVDD1 − AVSS can be a single 5 V
supply or a 2.5 V split supply. The split supply operation allows
true bipolar inputs. When using split supplies, consider the absolute
maximum ratings (see the Absolute Maximum Ratings section).
8 BITS, 16 BITS,
OR 24 BITS OF DATA
8-BIT COMMAND
CS
AVDD2 powers the internal 1.8 V analog LDO regulator. This
regulator powers the ADC core. AVDD2 is referenced to AVSS,
and AVDD2 − AVSS can range from to 2 V (minimum) to 5.5 V
(maximum).
CMD
DATA
DIN
SCLK
IOVDD powers the internal 1.8 V digital LDO regulator. This
regulator powers the digital logic of the ADC. IOVDD sets the
voltage levels for the SPI interface of the ADC. IOVDD is refer-
enced to DGND, and IOVDD − DGND can vary from 2 V
(minimum) to 5.5 V (maximum).
Figure 42. Writing to a Register
(8-Bit Command with Register Address Followed by Data of 8 Bits, 16 Bits, or
24 Bits; Data Length on DIN Is Dependent on the Register Selected)
8 BITS, 16 BITS,
24 BITS, OR
32 BITS OUTPUT
There is no specific requirement for a power supply sequence on
the AD7177-2. When all power supplies are stable, a device reset is
required; see the AD7177-2 Reset section for details on how to
reset the device.
8-BIT COMMAND
CS
DIGITAL COMMUNICATION
CMD
DIN
The AD7177-2 has a 3- or 4-wire SPI interface that is compatible
with QSPI™, MICROWIRE®, and DSPs. The interface operates
CS
in SPI Mode 3 and can be operated with
tied low. In SPI
DOUT/RDY
DATA
Mode 3, SCLK idles high, the falling edge of SCLK is the drive
edge, and the rising edge of SCLK is the sample edge. This
means that data is clocked out on the falling/drive edge and data
is clocked in on the rising/sample edge.
SCLK
Figure 43. Reading from a Register
(8-Bit Command with Register Address Followed by Data of 8 Bits, 16 Bits, or
24 Bits; Data Length on DOUT Is Dependent on the Register Selected)
Rev. B | Page 20 of 60
Data Sheet
AD7177-2
Reading the ID register is the recommended method for verifying
correct communication with the device. The ID register is a
read only register and contains the value 0x4FDX for the
AD7177-2. The communications register and the ID register
details are described in Table 8 and Table 9, respectively.
Figure 44 shows an overview of the suggested flow for changing
the ADC configuration, divided into the following three blocks:
•
•
•
Channel configuration (see Box A in Figure 44)
Setup configuration (see Box B in Figure 44)
ADC mode and interface mode configuration (see Box C
in Figure 44)
AD7177-2 RESET
In situations where interface synchronization is lost, a write
operation of at least 64 serial clock cycles with DIN high returns the
ADC to its default state by resetting the entire device, including
Channel Configuration
The AD7177-2 has four independent channels and four independ-
ent setups. The user can select any of the analog input pairs on
any channel, as well as any of the four setups for any channel,
giving the user full flexibility in the channel configuration. This
also allows per channel configuration when using differential
inputs and single-ended inputs because each channel can have
its own dedicated setup.
CS
the register contents. Alternatively, if
is being used with the
CS
digital interface, returning
high sets the digital interface to its
default state and halts any serial interface operation.
CONFIGURATION OVERVIEW
After power-on or reset, the AD7177-2 default configurations
are as follows. Note that only a few of the register setting
options are shown; this list is just an example. For full register
information, see the Register Details section.
Channel Registers
The channel registers are used to select which of the five analog
input pins (AIN0 to AIN4) are used as either the positive analog
input (AIN+) or the negative analog input (AIN−) for that
channel. This register also contains a channel enable/disable bit
and the setup selection bits, which are used to select from the
four available setups for this channel.
•
Channel configuration. CH0 is enabled, AIN0 is selected
as the positive input, and AIN1 is selected as the negative
input. Setup 0 is selected.
•
Setup configuration. The internal reference and the analog
input buffers are enabled. The reference input buffers are
disabled.
When the AD7177-2 is operating with more than one channel
enabled, the channel sequencer cycles through the enabled
channels in sequential order, from Channel 0 to Channel 3. If a
channel is disabled, it is skipped by the sequencer. Details of the
channel register for Channel 0 are shown in Table 10.
•
•
•
Filter configuration. The sinc5 + sinc 1 filter is selected and
the maximum output data rate of 10 kSPS is selected.
ADC mode. Continuous conversion mode and the internal
oscillator are enabled.
Interface mode. CRC and the data + status output are disabled.
A
B
C
CHANNEL CONFIGURATION
SELECT POSITIVE AND NEGATIVE INPUT FOR EACH ADC CHANNEL
SELECT ONE OF 4 SETUPS FOR ADC CHANNEL
SETUP CONFIGURATION
4 POSSIBLE ADC SETUPS
SELECT FILTER ORDER, OUTPUT DATA RATE, AND MORE
ADC MODE AND INTERFACE MODE CONFIGURATION
SELECT ADC OPERATING MODE, CLOCK SOURCE,
ENABLE CRC, DATA + STATUS, AND MORE
Figure 44. Suggested ADC Configuration Flow
Rev. B | Page 21 of 60
AD7177-2
Data Sheet
Table 8. Communications Register
Reg.
Name
Bits
Bit 7
Bit 6
Bit 5
Bit 5
Bit 4
Bit 4
Bit 3
Bit 3
Bit 2
Bit 2
Bit 1
Bit 1
Bit 0
Bit 0
Reset
RW
0x00
COMMS [7:0]
RA
0x00
W
WEN
R/W
Table 9. ID Register
Reg.
Name
Bits
Bit 7
Bit 6
Reset
RW
0x07
ID
[15:8]
[7:0]
ID[15:8]
ID[7:0]
0x4FDX
R
Table 10. Channel 0 Register
Reg.
Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reset
RW
0x10
CH0
[15:8] CH_EN0
[7:0]
Reserved
AINPOS0[2:0]
SETUP_SEL[2:0]
Reserved
AINNEG0
AINPOS0[4:3]
0x8001
RW
Rev. B | Page 22 of 60
Data Sheet
AD7177-2
Setup Configuration Registers
ADC Setups
The setup configuration registers allow the user to select the output
coding of the ADC by selecting between bipolar and unipolar. In
bipolar mode, the ADC accepts negative differential input voltages,
and the output coding is offset binary. In unipolar mode, the ADC
accepts only positive differential voltages, and the coding is straight
binary. In either case, the input voltage must be within the AVDD1/
AVSS supply voltages. The user can select the reference source
using these registers. Three options are available: an internal
2.5 V reference, an external reference connected between the
REF+ and REF− pins, or AVDD1 − AVSS. The analog input and
reference input buffers can also be enabled or disabled using
this register.
The AD7177-2 has four independent setups. Each setup consists
of the following four registers:
•
•
•
•
Setup configuration register
Filter configuration register
Gain register
Offset register
For example, Setup 0 consists of Setup Configuration Register 0,
Filter Configuration Register 0, Gain Register 0, and Offset
Register 0. Figure 45 shows the grouping of these registers. The
setup is selectable from the channel registers (see the Channel
Configuration section), which allows each channel to be
assigned to one of four separate setups. Table 11 through Table 14
show the four registers associated with Setup 0. This structure is
repeated for Setup 1 to Setup 3.
Filter Configuration Registers
The filter configuration registers select which digital filter is
used at the output of the ADC modulator. The order of the filter
and the output data rate is selected by setting the bits in this
register. For more information, see the Digital Filters section.
SETUP CONFIG
REGISTERS
FILTER CONFIG
REGISTERS
GAIN REGISTERS*
OFFSET REGISTERS
SETUPCON0
SETUPCON1
SETUPCON2
SETUPCON3
FILTCON0
FILTCON1
FILTCON2
FILTCON3
GAIN0
GAIN1
GAIN2
GAIN3
OFFSET0
0x30
0x20
0x21
0x22
0x23
0x28
0x29
0x2A
0x2B
0x38
0x39
0x3A
0x3B
OFFSET1
0x31
OFFSET2
0x32
OFFSET3
0x33
SELECT PERIPHERAL
FUNCTIONS FOR
ADC CHANNEL
SELECT DIGITAL
FILTER TYPE
GAIN CORRECTION
OPTIONALLY
OFFSET CORRECTION
OPTIONALLY PROGRAMMED
PER SETUP AS REQUIRED
AND OUTPUT DATA RATE
PROGRAMMED
PER SETUP AS REQUIRED
(*FACTORY CALIBRATED)
DATA OUTPUT CODING
REFERENCE SOURCE
INPUT BUFFERS
SINC5 + SINC1
SINC3
SINC3 MAP
ENHANCED 50Hz AND 60Hz
Figure 45. ADC Setup Register Grouping
Table 11. Setup Configuration 0 Register
Reg. Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reset
RW
0x20 SETUPCON0 [15:8]
Reserved
BI_UNIPOLAR0 REFBUF0+ REFBUF0− AINBUF0+ AINBUF0− 0x1320
RW
[7:0] BURNOUT_EN0 Reserved
REF_SEL0
Reserved
Table 12. Filter Configuration 0 Register
Reg. Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reset
RW
0x28 FILTCON0 [15:8] SINC3_MAP0
[7:0] Reserved
Reserved
ORDER0
ENHFILTEN0
ENHFILT0
0x0507
RW
ODR0
Table 13. Gain Configuration 0 Register
Reg. Name
Bits
Bits[23:0]
Reset
RW
0x38 GAIN0
[23:0]
GAIN0[23:0]
0x5XXXX0 RW
Table 14. Offset Configuration 0 Register
Reg. Name
Bits
Bits[23:0]
Reset
RW
0x30 OFFSET0
[23:0]
OFFSET0[23:0]
0x800000 RW
Rev. B | Page 23 of 60
AD7177-2
Data Sheet
ADC Mode and Interface Mode Configuration
Gain Registers
The ADC mode register and the interface mode register configure
the core peripherals for use by the AD7177-2 and the mode for
the digital interface.
The gain registers are 24-bit registers that hold the gain
calibration coefficient for the ADC. The gain registers are
read/write registers. These registers are configured at power-on
with factory calibrated coefficients. Therefore, every device has
different default coefficients. The default value is automatically
overwritten if a system full-scale calibration is initiated by the
user or if the gain register is written to by the user. For more
information on calibration, see the Operating Modes section.
ADC Mode Register
The ADC mode register primarily sets the conversion mode of
the ADC to either continuous or single conversion. The user
can also select the standby and power-down modes, as well as
any of the calibration modes. In addition, this register contains
the clock source select bits and the internal reference enable bits.
The reference select bits are contained in the setup configuration
registers (see the ADC Setups section for more information).
Offset Registers
The offset registers hold the offset calibration coefficient for the
ADC. The power-on reset value of the offset registers is 0x800000.
The offset registers are 24-bit read/write registers. The power-
on reset value is automatically overwritten if an internal or
system zero-scale calibration is initiated by the user or if the offset
registers are written to by the user.
Interface Mode Register
The interface mode register configures the digital interface
operation. This register allows the user to control data-word
length, CRC enable, data + status read, and continuous read mode.
The details of the ADC mode and interface mode registers are
shown in Table 15 and Table 16, respectively. For more information,
see the Digital Interface section.
Table 15. ADC Mode Register
Reg. Name
0x01 ADCMODE [15:8] REF_EN
[7:0] Reserved
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Reserved
Bit 2
CLOCKSEL
Bit 1
Delay
Reserved
Bit 0
Reset
RW
HIDE_DELAY SING_CYC
Mode
0x8000 RW
Table 16. Interface Mode Register
Reg. Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Reserved
CRC_EN WL32
Bit 1
Bit 0
Reset
0x0000
RW
0x02 IFMODE [15:8]
[7:0]
Reserved
ALT_SYNC
Reserved
IOSTRENGTH
DOUT_RESET
Reserved
RW
CONTREAD
DATA_STAT
REG_CHECK
Rev. B | Page 24 of 60
Data Sheet
AD7177-2
Understanding Configuration Flexibility
Programming the gain and offset registers is optional for any
use case, as indicated by the dashed lines between the register
blocks.
The most straightforward implementation of the AD7177-2 is
to use two differential inputs with adjacent analog inputs and
run both of them with the same setup, gain correction, and
offset correction register. In this case, the user selects the
following differential inputs: AIN0/AIN1 and AIN2/AIN3. In
Figure 46, the registers shown in black font must be pro-
grammed for such a configuration. The registers shown in gray
font are redundant in this configuration.
An alternative way to implement these two fully differential
inputs is by taking advantage of the four available setups.
Motivation for doing this includes having a different speed/noise
requirement on each of the differential inputs, or there may be a
specific offset or gain correction for each channel. Figure 47
shows how each of the differential inputs can use a separate
setup, allowing full flexibility in the configuration of each channel.
CHANNEL
REGISTERS
SETUP CONFIG
REGISTERS
FILTER CONFIG
REGISTERS
GAIN REGISTERS*
OFFSET REGISTERS
AIN0
AIN1
AIN2
AIN3
AIN4
CH0
SETUPCON0
FILTCON0
GAIN0
0x38
OFFSET0
0x30
0x10
0x20
0x28
0x29
0x2A
0x2B
CH1
CH2
CH3
SETUPCON1
SETUPCON2
SETUPCON3
FILTCON1
FILTCON2
FILTCON3
GAIN1
GAIN2
GAIN3
OFFSET1
0x31
0x21
0x22
0x23
0x39
0x3A
0x3B
0x11
0x12
0x13
OFFSET2
0x32
OFFSET3
0x33
SELECT ANALOG INPUT PAIRS
ENABLE THE CHANNEL
SELECT SETUP 0
SELECT PERIPHERAL
FUNCTIONS FOR
ADC CHANNEL
SELECT DIGITAL
FILTER TYPE
AND OUTPUT DATA RATE
GAIN CORRECTION
OPTIONALLY
PROGRAMMED
OFFSET CORRECTION
OPTIONALLY PROGRAMMED
PER SETUP AS REQUIRED
PER SETUP AS REQUIRED
(*FACTORY CALIBRATED)
DATA OUTPUT CODING
REFERENCE SOURCE
INPUT BUFFERS
SINC5 + SINC1
SINC3
SINC3 MAP
ENHANCED 50Hz AND 60Hz
Figure 46. Two Fully Differential Inputs, Both Using a Single Setup (SETUPCON0; FILTCON0; GAIN0; OFFSET0)
CHANNEL
REGISTERS
SETUP CONFIG
REGISTERS
FILTER CONFIG
REGISTERS
GAIN REGISTERS*
OFFSET REGISTERS
AIN0
AIN1
AIN2
AIN3
AIN4
CH0
SETUPCON0
FILTCON0
0x28
GAIN0
0x38
OFFSET0
0x30
0x10
0x20
CH1
CH2
CH3
SETUPCON1
SETUPCON2
SETUPCON3
FILTCON1
FILTCON2
FILTCON3
GAIN1
GAIN2
GAIN3
OFFSET1
0x31
0x21
0x22
0x23
0x29
0x2A
0x2B
0x39
0x3A
0x3B
0x11
0x12
0x13
OFFSET2
0x32
OFFSET3
0x33
SELECT PERIPHERAL
FUNCTIONS FOR
ADC CHANNEL
SELECT DIGITAL
FILTER TYPE
AND OUTPUT DATA RATE
GAIN CORRECTION
OPTIONALLY
PROGRAMMED
OFFSET CORRECTION
OPTIONALLY PROGRAMMED
PER SETUP AS REQUIRED
PER SETUP AS REQUIRED
(*FACTORY CALIBRATED)
DATA OUTPUT CODING
REFERENCE SOURCE
INPUT BUFFERS
SINC5 + SINC1
SINC3
SINC3 MAP
ENHANCED 50Hz AND 60Hz
Figure 47. Two Fully Differential Inputs with a Setup per Channel
Rev. B | Page 25 of 60
AD7177-2
Data Sheet
Figure 48 shows an example of how the channel registers span
between the analog input pins and the setup configurations
downstream. In this example, one differential input and two single-
ended inputs are required. The single-ended inputs are the
AIN2/AIN4 and AIN3/AIN4 combinations. The differential input
pair is AIN0/AIN1and uses Setup 0. The two single-ended input
pairs are set up as diagnostics; therefore, use a separate setup
from the differential input but share a setup between them,
Setup 1. Given that two setups are selected for use, the
programmed as required. Optional gain and offset correction
can be employed on a per setup basis by programming the
GAIN0 and GAIN1 registers and the OFFSET0 and OFFSET1
registers.
In the example shown in Figure 48, the CH0 to CH2 registers
are used. Setting the MSB in each of these registers, the CH_EN0
to CH_EN2 bits, enables the three combinations via the crosspoint
mux. When the AD7177-2 converts, the sequencer transitions
in ascending sequential order from CH0 to CH1 to CH2 before
looping back to CH0 to repeat the sequence.
SETUPCON0 and SETUPCON1 registers are programmed as
required, and the FILTCON0 and FILTCON1 registers are also
CHANNEL
REGISTERS
SETUP CONFIG
REGISTERS
FILTER CONFIG
REGISTERS
GAIN REGISTERS*
OFFSET REGISTERS
AIN0
AIN1
AIN2
AIN3
AIN4
CH0
SETUPCON0
FILTCON0
GAIN0
0x38
OFFSET0
0x30
0x10
0x20
0x28
0x29
0x2A
0x2B
CH1
CH2
CH3
SETUPCON1
SETUPCON2
SETUPCON3
FILTCON1
FILTCON2
FILTCON3
GAIN1
GAIN2
GAIN3
OFFSET1
0x31
0x21
0x22
0x23
0x39
0x3A
0x3B
0x11
0x12
0x13
OFFSET2
0x32
OFFSET3
0x33
SELECT ANALOG INPUT PARTS
ENABLE THE CHANNEL
SELECT SETUP
SELECT PERIPHERAL
FUNCTIONS FOR
ADC CHANNEL
SELECT DIGITAL
FILTER TYPE
AND OUTPUT DATA RATE
GAIN CORRECTION
OPTIONALLY
PROGRAMMED
OFFSET CORRECTION
OPTIONALLY PROGRAMMED
PER SETUP AS REQUIRED
PER SETUP AS REQUIRED
(*FACTORY CALIBRATED)
DATA OUTPUT CODING
REFERENCE SOURCE
INPUT BUFFERS
SINC5 + SINC1
SINC3
SINC3 MAP
ENHANCED 50Hz AND 60Hz
Figure 48. Mixed Differential and Single-Ended Configuration Using Multiple Shared Setups
Rev. B | Page 26 of 60
Data Sheet
AD7177-2
CIRCUIT DESCRIPTION
AVDD1
BUFFERED ANALOG INPUT
AIN0
AIN1
The AD7177-2 has true rail-to-rail, integrated, precision unity-
gain buffers on both ADC analog inputs. The buffers provide
the benefit of giving the user high input impedance with only
30 nA typical input current, allowing high impedance sources
to be connected directly to the analog inputs. The buffers fully
drive the internal ADC switch capacitor sampling network,
simplifying the analog front-end circuit requirements while
consuming a very efficient 2.9 mA typical per buffer. Each analog
input buffer amplifier is fully chopped, meaning that it minimizes
the offset error drift and 1/f noise of the buffer. The 1/f noise
profile of the ADC and buffer combined is shown in Figure 49.
0
AVSS
AVDD1
Ø1
+IN
CS1
CS2
AVSS
Ø2
Ø2
AVDD1
AIN2
AVSS
–IN
AVDD1
Ø1
AIN3
AIN4
–20
–40
AVSS
AVDD1
–60
–80
AVSS
–100
–120
–140
–160
–180
–200
Figure 50. Simplified Analog Input Circuit
The CS1 and CS2 capacitors each have a magnitude in the order
of a number of picofarads. This capacitance is the combination
of both the sampling capacitance and the parasitic capacitance.
Fully Differential Inputs
Because the AIN0 to AIN4 analog inputs are connected to a
crosspoint multiplexer, any combination of signals can be used
to create an analog input pair. The crosspoint multiplexer allows
the user to select two fully differential inputs or four single-
ended inputs.
1
10
100
1000
FREQUENCY (Hz)
Figure 49. Shorted Input FFT (Analog Input Buffers Enabled)
The analog input buffers do not suffer from linearity
degradation when operating at the rails, unlike many discrete
amplifiers. When operating at or close to the AVDD1 and AVSS
supply rails, there is an increase in input current. This increase
is most notable at higher temperatures. Figure 38 and Figure 39
show the analog input current for various conditions. With the
analog input buffers disabled, the average input current to the
AD7177-2 changes linearly with the differential input voltage at
a rate of 48 µA /V.
If two fully differential input paths are connected to the AD7177-2,
using AIN0/AIN1 as one differential input pair and AIN2/AIN3
as the second differential input pair is recommended. This is
due to the relative locations of these pins to each other. Decouple all
analog inputs to AVSS.
Single-Ended Inputs
The user can also choose to measure four different single-ended
analog inputs. In this case, each of the analog inputs is converted
as the difference between the single-ended input to be meas-
ured and a set analog input common pin. Because there is a
crosspoint multiplexer, the user can set any of the analog inputs
as the common pin. An example of such a scenario is to connect
the AIN4 pin to AVSS or to the REFOUT voltage (that is, AVSS
+ 2.5 V) and select this input when configuring the crosspoint
multiplexer. When using the AD7177-2 with single-ended
inputs, the INL specification is degraded.
CROSSPOINT MULTIPLEXER
There are five analog input pins: AIN0, AIN1, AIN2, AIN3, and
AIN4. Each of these pins connects to the internal crosspoint
multiplexer. The crosspoint multiplexer enables any of these inputs
to be configured as an input pair, either single-ended or fully
differential. The AD7177-2 can have up to four active channels.
When more than one channel is enabled, the channels are
automatically sequenced in order from the lowest enabled channel
number to the highest enabled channel number. The output of
the multiplexer is connected to the input of the integrated true
rail-to-rail buffers. These can be bypassed and the multiplexer
output can be directly connected to the switched-capacitor input
of the ADC. The simplified analog input circuit is shown in
Figure 50.
Rev. B | Page 27 of 60
AD7177-2
Data Sheet
AD7177-2, the internal reference is enabled by default and is
output on the REFOUT pin. When an external reference is used
instead of the internal reference to supply the AD7177-2,
attention must be paid to the output of the REFOUT pin. If the
internal reference is not being used elsewhere in the application,
ensure that the REFOUT pin is not hardwired to AVSS because
this draws a large current on power-up. On power-up, if the
internal reference is not being used, write to the ADC mode
register, disabling the internal reference. This is controlled by
the REF_EN bit (Bit 15) in the ADC mode register, which is
shown in Table 18.
AD7177-2 REFERENCE
The AD7177-2 offers the user the option of either supplying an
external reference to the REF+ and REF− pins of the device or
allowing the use of the internal 2.5 V, low noise, low drift reference.
Select the reference source to be used by the analog input by setting
the REF_SELx bits (Bits[5:4]) in the setup configuration registers
appropriately. The structure of the Setup Configuration 0 register
is shown in Table 17. The AD7177-2 defaults on power-up to
use the internal 2.5 V reference.
External Reference
The AD7177-2 has a fully differential reference input applied
through the REF+ and REF− pins. Standard low noise, low driꢀ
voltage references, such as the ADR445, ADR444, and ADR441,
are recommended for use. Apply the external reference to the
AD7177-2 reference pins as shown in Figure 51. Decouple the
output of any external reference to AVSS. As shown in Figure 51,
the ADR445 output is decoupled with a 0.1 μF capacitor at its
output for stability purposes. The output is then connected to a
4.7 μF capacitor, which acts as a reservoir for any dynamic
charge required by the ADC, and followed by a 0.1 μF
Internal Reference
The AD7177-2 includes its own low noise, low drift voltage
reference. The internal reference has a 2.5 V output. The internal
reference is output on the REFOUT pin after the REF_EN bit in
the ADC mode register is set and is decoupled to AVSS with a
0.1 μF capacitor. The AD7177-2 internal reference is enabled by
default on power-up and is selected as the reference source for
the ADC. When using the internal reference, the INL performance
is degraded as shown in Figure 19.
The REFOUT signal is buffered before being output to the pin.
The signal can be used externally in the circuit as a common-mode
source for external amplifier configurations.
decoupling capacitor at the REF+ input. This capacitor is placed
as close as possible to the REF+ and REF− pins. e REF− pin
is connected directly to the AVSS potential. On power-up of the
AD7177-2
5.5V TO 18V
ADR4452
3
2
REF+
REF–
0.1µF
1
5V VREF
1
0.1µF
4.7µF
0.1µF
1
1
1
1
2
ALL DECOUPLING IS TO AVSS.
ANY OF THE ADR440/ADR441/ADR443/ADR444/ADR445 FAMILY OF REFERENCES
CAN BE USED. THE ADR444 AND ADR441 BOTH ENABLE REUSE OF THE
5V ANALOG SUPPLY NEEDED FOR AVDD1 TO POWER THE REFERENCE V
.
IN
Figure 51. External Reference ADR445 Connected to the AD7177-2 Reference Pins
Table 17. Setup Configuration 0 Register
Reg. Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
BI_UNIPOLAR0 REFBUF0+ REFBUF0− AINBUF0+
REF_SEL0 Reserved
Bit 3
Bit 2
Bit 1
Bit 0
Reset RW
0x20 SETUPCON0 [15:8]
[7:0]
Reserved
AINBUF0−
0x1320 RW
BURNOUT_EN0 Reserved
Table 18. ADC Mode Register
Reg.
Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
CLOCKSEL
Bit 1
Delay
Reserved
Bit 0
Reset
0x8000
RW
0x01
ADCMODE [15:8]
[7:0]
REF_EN
Reserved
HIDE_DELAY
SING_CYC
Mode
Reserved
RW
Rev. B | Page 28 of 60
Data Sheet
AD7177-2
further exaggerated if the IOSTRENGTH bit is set at higher
IOVDD levels (see Table 28 for more information).
BUFFERED REFERENCE INPUT
The AD7177-2 has true rail-to-rail, integrated, precision unity-
gain buffers on both ADC reference inputs. The buffers provide
the benefit of giving the user high input impedance and allow
high impedance external sources to be directly connected to the
reference inputs. The integrated reference buffers can fully drive
the internal reference switch capacitor sampling network,
simplifying the reference circuit requirements while consuming
a very efficient 2.9 mA typical per buffer. Each reference input
buffer amplifier is fully chopped, meaning that it minimizes the
offset error drift and 1/f noise of the buffer. When using an
external reference, such as the ADR445, ADR444, and ADR441,
these buffers are not required because these references, with
proper decoupling, can drive the reference inputs directly.
External Crystal
If higher precision, lower jitter clock sources are required, the
AD7177-2 can use an external crystal to generate the master
clock. The crystal is connected to the XTAL1 and XTAL2/CLKIO
pins. A recommended crystal for use is the FA-20H, a 16 MHz,
10 ppm, 9 pF crystal from Epson-Toyocom, that is available in a
surface-mount package. As shown in Figure 52, insert two
capacitors from the traces connecting the crystal to the XTAL1
and XTAL2/CLKIO pins. These capacitors allow circuit tuning.
Connect these capacitors to the DGND pin. The value for these
capacitors depends on the length and capacitance of the trace
connections between the crystal and the XTAL1 and XTAL2/
CLKIO pins. Therefore, the values of these capacitors differ
depending on the printed circuit board (PCB) layout and the
crystal employed.
CLOCK SOURCE
The AD7177-2 uses a nominal master clock of 16 MHz. The
AD7177-2 can source its sampling clock from one of three
sources:
AD7177-2
Cx1
*
•
•
•
Internal oscillator
External crystal
External clock source
9
XTAL1
XTAL2/CLKIO 10
Cx2
All output data rates listed in this data sheet relate to a master
clock rate of 16 MHz. Using a lower clock frequency from, for
instance, an external source scales any listed data rate proportion-
ally. To achieve the specified data rates, particularly rates for the
rejection of 50 Hz and 60 Hz, use a 16 MHz clock. The source
of the master clock is selected by setting the CLOCKSEL bits
(Bits[3:2]) in the ADC mode register as shown in Table 18. The
default operation on power-up and reset of the AD7177-2 is to
operate with the internal oscillator. It is possible to fine tune the
output data rate and filter notch at low output data rates using
the SINC3_MAPx bit. See the Sinc3 Filter section for more
information.
*
*DECOUPLE TO DGND.
Figure 52. External Crystal Connections
The external crystal circuitry can be sensitive to the SCLK
edges, depending on SCLK frequency, IOVDD voltage, crystal
circuitry layout, and the crystal used. During crystal startup, any
disturbances caused by the SLCK edges may cause double edges
on the crystal input, resulting in invalid conversions until the
crystal voltage has reached a high enough level such that any
interference from the SCLK edges is insufficient to cause double
clocking. This double clocking can be avoided by ensuring that
the crystal circuitry has reached a sufficient voltage level after
startup before applying any SCLK signal.
Internal Oscillator
The internal oscillator runs at 16 MHz and can be used as the
ADC master clock. It is the default clock source for the AD7177-2
and is specified with an accuracy of 2.5%.
Due to the nature of the crystal circuitry, it is recommended
that empirical testing of the circuit be performed under the
required conditions, with the final PCB layout and crystal, to
ensure correct operation.
There is an option to allow the internal clock oscillator to be
output on the XTAL2/CLKIO pin. The clock output is driven to
the IOVDD logic level. Use of this option can affect the dc
performance of the AD7177-2 due to the disturbance intro-
duced by the output driver. The extent to which the performance
is affected depends on the IOVDD voltage supply. Higher
IOVDD voltages create a wider logic output swing from the
driver and affect performance to a greater extent. This effect is
External Clock
The AD7177-2 can also use an externally supplied clock. In
systems where this is desirable, the external clock is routed to
the XTAL2/CLKIO pin. In this configuration, the XTAL2/CLKIO
pin accepts the externally sourced clock and routes it to the
modulator. The logic level of this clock input is defined by the
voltage applied to the IOVDD pin.
Rev. B | Page 29 of 60
AD7177-2
Data Sheet
DIGITAL FILTERS
The AD7177-2 has three flexible filter options to allow optimiza-
tion of noise, settling time, and rejection, as follows:
SINC3 FILTER
The sinc3 filter achieves the best single-channel noise performance
at lower rates and is, therefore, most suitable for single-channel
applications. The sinc3 filter always has a settling time, tSETTLE
•
•
•
Sinc5 + sinc1 filter
Sinc3 filter
Enhanced 50 Hz and 60 Hz rejection filters
,
equal to
tSETTLE = 3/Output Data Rate
50Hz AND 60Hz
POSTFILTER
Figure 55 shows the frequency domain filter response for the
sinc3 filter. The sinc3 filter has good roll-off over frequency and
has wide notches for good notch frequency rejection.
SINC1
SINC5
SINC3
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
Figure 53. Digital Filter Block Diagram
The filter and output data rate are configured by setting the
appropriate bits in the filter configuration register for the
selected setup. Each channel can use a different setup and,
therefore, a different filter and output data rate. See the Register
Details section for more information.
SINC5 + SINC1 FILTER
The sinc5 + sinc1 filter is targeted at multiplexed applications
and achieves single cycle settling at output data rates of 10 kSPS and
lower. The sinc5 block output is fixed at the maximum rate of
10 kSPS, and the sinc1 block output data rate can be varied to
control the final ADC output data rate. Figure 54 shows the
frequency domain response of the sinc5 + sinc1 filter at a 50 SPS
ODR. The sinc5 + sinc1 filter has a slow roll-off over frequency and
narrow notches.
–120
0
50
100
FREQUENCY (Hz)
150
Figure 55. Sinc3 Filter Response
The ODR with the accompanying settling time and rms noise
for the sinc3 filter are shown in Table 21 and Table 22. It is possible
to finely tune the output data rate for the sinc3 filter by setting the
SINC3_MAPx bits in the filter configuration registers. If this bit is
set, the mapping of the filter register changes to directly program
the decimation rate of the sinc3 filter. All other options are
eliminated. The data rate when on a single channel can be
calculated using the following equation:
0
–20
–40
–60
fMOD
Output Data Rate =
32 × FILTCONx[14:0]
–80
where:
–100
–120
fMOD is the modulator rate (MCLK/2) and is 8 MHz for a
16 MHz MCLK.
FILTCONx[14:0] are the contents on the filter configuration
registers excluding the MSB.
0
50
100
FREQUENCY (Hz)
150
Figure 54. Sinc5 + Sinc1 Filter Response at 50 SPS ODR
For example, an output data rate of 50 SPS can be achieved with
SINC3_MAPx enabled by setting the FILTCONx[14:0] bits to a
value of 5000.
The ODR with the accompanying settling time and rms noise
for the sinc5 + sinc1 filter are shown in Table 19 and Table 20.
Rev. B | Page 30 of 60
Data Sheet
AD7177-2
Figure 57 shows the same step on the analog input but with
single cycle settling enabled. The analog input requires at least a
single cycle for the output to be fully settled. The output data
SINGLE CYCLE SETTLING
The AD7177-2 can be configured by setting the SING_CYC bit
in the ADC mode register so that only fully settled data is output,
effectively putting the ADC into a single cycle settling mode. This
mode achieves single cycle settling by reducing the output data
rate to be equal to the settling time of the ADC for the selected
output data rate. This bit has no effect with the sinc5 + sinc1
filter at output data rates of 10 kSPS and lower.
RDY
rate, as indicated by the
signal, is reduced to equal the
settling time of the filter at the selected output data rate.
ANALOG
INPUT
FULLY
SETTLED
ADC
OUTPUT
Figure 56 shows a step on the analog input with this mode
disabled and the sinc3 filter selected. The analog input requires
at least three cycles after the step change for the output to reach
the final settled value.
tSETTLE
Figure 57. Step Input with Single Cycle Settling
ANALOG
INPUT
FULLY
SETTLED
ADC
OUTPUT
1/ODR
Figure 56. Step Input Without Single Cycle Settling
Table 19. Output Data Rate, Settling Time, and Noise Using the Sinc5 + Sinc1 Filter with Input Buffers Disabled
Output Data Rate
(SPS/Channel);
SING_CYC = 1 or
with Multiple
Channels
Default Output
Data Rate (SPS);
SING_CYC = 0
and Single
Effective
Resolution
with 5 V
Reference
(Bits)
Dynamic
Range with
5 V
Reference
(dB)
Peak-to-Peak
Resolution
with 5 V
Reference
(Bits)
Notch
Frequency
(Hz)
Settling
Time1
Channel
Noise
(µV rms)
Noise
Enabled1
Enabled1
(µV p-p)2
10,000
5000
2500
1000
500
397.5
200
100
59.92
49.96
20
16.66
10
10,000
5000
2500
1000
500.0
397.5
200.0
100
59.92
49.96
20.00
16.66
10.00
5.00
100 µs
200 µs
400 µs
1.0 ms
2.0 ms
2.516 ms
5.0 ms
11,905
5435
2604
1016
504
400.00
200.64
100.16
59.98
50.00
20.01
16.66
10.00
5.00
2.5
1.7
1.2
21.9
22.5
23
23.6
24.3
24.4
25
25.6
25.8
26
26.7
26.7
26.8
27.3
123
18.3
12
8.2
5.2
3.2
3
19.1
19.7
20.2
20.9
21.6
21.7
22.3
22.9
23.1
23.3
24
126.4
129.4
133.2
135.9
137
139.8
143
145.4
145.9
150.1
151
0.77
0.57
0.5
0.36
0.25
0.19
0.18
0.11
0.1
2
10 ms
1.3
1.1
0.95
0.6
0.45
0.4
0.34
16.67 ms
20.016 ms
50.0 ms
60.02 ms
100 ms
200 ms
24.1
24.2
24.6
0.08
0.07
152.9
154.1
5
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.
2 Measurement taken using 1000 samples.
Rev. B | Page 31 of 60
AD7177-2
Data Sheet
Table 20. Output Data Rate, Settling Time, and Noise Using the Sinc5 + Sinc1 Filter with Input Buffers Enabled
Default
Output Data
Output Data Rate
(SPS/Channel);
SING_CYC = 1 or
with Multiple
Rate (SPS);
SING_CYC = 0
and Single
Channel
Effective
Resolution
Noise with 5 V
Dynamic
Range
with 5 V
Reference
(dB)
Peak-to-Peak
Resolution with
5 V Reference
Notch
Frequency
(Hz)
Settling
Time1
(µV
rms)
Reference
(Bits)
Noise
Enabled1
Channels Enabled1
(µV p-p)2 (Bits)
10,000
5000
2500
1000
500
10,000
5000
2500
1000
500.0
397.5
100 µs
200 µs
400 µs
1.0 ms
2.0 ms
2.516
ms
5.0 ms
10 ms
11,905
5435
2604
1016
504
3
21.7
22.2
22.7
23.4
23.8
121.4
124.5
127.4
131.7
134.3
23
16
10
5.7
3.9
3.7
18.7
19.3
19.9
20.7
21.3
2.1
1.5
0.92
0.68
0.6
397.5
400.00
24.1
135.4
21.4
22.1
22.5
200
100
59.92
200.0
100
59.92
200.64
100.16
59.98
0.43
0.32
0.23
24.8
25.2
138.3
140.9
2.2
1.7
1.2
16.67
ms
25.7
143.7
23
49.96
49.96
20.016
ms
50.0 ms
60.02
ms
100 ms
200 ms
50.00
0.2
1
26
144.9
148
23.3
23.7
20
16.66
20.00
16.66
20.01
16.66
0.14
0.13
26.4
26.6
0.75
0.66
148.7
23.9
24.1
24.6
10
5
10.00
5.00
10.00
5.00
0.1
0.07
26.7
26.7
151
154.1
0.47
0.32
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.
2 Measurement taken using 1000 samples.
Table 21. Output Data Rate, Settling Time, and Noise Using the Sinc3 Filter with Input Buffers Disabled
Output Data Rate
(SPS/Channel);
SING_CYC = 1 or
with Multiple
Default Output
Data Rate (SPS);
SING_CYC = 0 and
Single Channel
Enabled1
Dynamic
Range
Peak-to-Peak
Resolution
with 5 V
Reference
(Bits)
Notch
Fre-
quency
(Hz)
Effective
Noise Resolution with with 5 V
Settling
Time1
(µV
rms)
5 V Reference
(Bits)
Reference Noise
(dB)
Channels Enabled1
(µV p--p)2
10,000
5000
2500
1000
500
400
200
100
60
50
20
16.67
10
5
3333
1667
833
333.3
166.7
133.3
66.7
33.33
19.99
16.67
6.67
300 µs
6 µs
1.2 ms
3 ms
10,000
5000
2500
1000
500
400
200
100
59.98
50
1.8
1.3
22.4
22.9
23.4
24
24.6
24.8
25.5
26
26.3
26.5
26.9
27
27.1
27.5
125.9
128.7
131.8
136
138.1
138.9
143
144.9
148.7
148.7
152.9
154.1
155.4
157
14
9.5
6
19.4
20
0.91
0.56
0.44
0.4
0.25
0.2
0.13
0.13
0.08
0.07
0.06
0.05
20.7
21.3
21.9
22.1
22.8
23.3
23.6
23.8
24.2
24.3
24.4
24.8
3.9
2.5
2.3
1.4
1
0.8
0.7
0.42
0.37
0.28
0.21
6 ms
7.5 ms
15 ms
30 ms
50.02 ms
60 ms
150 ms
180 ms
300 ms
600 ms
20
16.67
10
5.56
3.33
1.67
5
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.
2 Measurement taken using 1000 samples.
Rev. B | Page 32 of 60
Data Sheet
AD7177-2
Table 22. Output Data Rate, Settling Time, and Noise Using the Sinc3 Filter with Input Buffers Enabled
Output Data Rate
(SPS/Channel);
SING_CYC = 1 or
with Multiple
Default Output
Data Rate (SPS);
SING_CYC = 0 and
Single Channel
Enabled1
Effective
Resolution
with 5 V
Reference
(Bits)
Dynamic
Range
with 5 V
Reference
(dB)
Peak-to-Peak
Resolution
with 5 V
Reference
(Bits)
Notch
Frequency
(Hz)
Settling
Time1
Noise
(µV rms)
Noise
Channels Enabled1
(µV p-p)2
10,000
5000
2500
1000
500
400
200
100
60
50
20
16.67
10
5
3333
1667
833
333.3
166.7
133.3
66.7
33.33
19.99
16.67
6.67
300 µs
6 µs
1.2 ms
3 ms
10,000
5000
2500
1000
500
400
200
100
59.98
50
2.1
1.5
1.1
22.2
22.7
23.1
23.7
24.4
24.5
25.1
25.7
25.8
26.2
26.7
26.8
26.9
27.2
124.5
127.4
130.1
133.9
136.6
138.7
140.9
144.9
146.4
147.4
148.7
149.4
151
16
11
7
4.5
3
2.7
1.8
1.2
1.1
0.83
0.61
0.6
0.55
0.35
19.3
19.8
20.4
21.1
21.7
21.8
22.4
23
23.1
23.5
24
24.1
24.2
24.5
0.71
0.52
0.41
0.32
0.2
0.17
0.15
0.13
0.12
0.1
6 ms
7.5 ms
15 ms
30 ms
50.02 ms
60 ms
150 ms
180 ms
300 ms
600 ms
20
16.67
10
5.56
3.33
1.67
5
0.08
152.9
1 The settling time is rounded to the nearest microsecond. This is reflected in the output data rate and channel switching rate. Channel switching rate = 1 ÷ settling time.
2 Measurement taken using 1000 samples.
Rev. B | Page 33 of 60
AD7177-2
Data Sheet
sinc1 filter must be selected when using the enhanced filters to
achieve the specified settling time and noise performance. Table 23
shows the output data rates with the accompanying settling
time, rejection, and rms noise. Figure 58 to Figure 65 show the
frequency domain plots of the responses from the enhanced filters.
ENHANCED 50 HZ AND 60 HZ REJECTION FILTERS
The enhanced filters are designed to provide rejection of 50 Hz
and 60 Hz simultaneously and to allow the user to trade off
settling time and rejection. These filters can operate up to
27.27 SPS or can reject up to 90 dB of 50 Hz 1 Hz and 60 Hz
1 Hz interference. These filters are realized by postfiltering
the output of the sinc5 + sinc1 filter. For this reason, the sinc5 +
Table 23. Enhanced Filters Output Data Rate, Noise, Settling Time, and Rejection Using the Enhanced Filters
Settling
Time
Output Data Rate (SPS) (ms)
Simultaneous Rejection of 50 Hz
1 Hz and 60 Hz 1 Hz (dB)1
Noise Peak-to-Peak
(µV rms) Resolution (Bits)
Comments
Input Buffers Disabled
27.27
25
20
16.667
36.67
40.0
50.0
60.0
47
62
85
90
0.22
0.2
0.2
22.7
22.9
22.9
23
See Figure 58 and Figure 61
See Figure 59 and Figure 62
See Figure 60 and Figure 63
See Figure 64 and Figure 65
0.17
Input Buffers Enabled
27.27
25
20
36.67
40.0
50.0
60.0
47
62
85
90
0.22
0.22
0.21
0.21
22.7
22.7
22.8
22.8
See Figure 58 and Figure 61
See Figure 59 and Figure 62
See Figure 60 and Figure 63
See Figure 64 and Figure 65
16.667
1 Master clock = 16.00 MHz.
Rev. B | Page 34 of 60
Data Sheet
AD7177-2
0
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–100
0
0
0
100
200
300
400
500
600
600
600
40
45
50
55
60
65
70
FREQUENCY (Hz)
FREQUENCY (Hz)
Figure 58. 27.27 SPS ODR, 36.67 ms Settling Time
Figure 61. 27.27 SPS ODR, 36.67 ms Settling Time at 50 Hz/60 Hz
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–100
100
200
300
400
500
40
45
50
55
60
65
70
FREQUENCY (Hz)
FREQUENCY (Hz)
Figure 59. 25 SPS ODR, 40 ms Settling Time
Figure 62. 25 SPS ODR, 40 ms Settling Time at 50 Hz/60 Hz
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
100
200
300
400
500
40
45
50
55
60
65
70
FREQUENCY (Hz)
FREQUENCY (Hz)
Figure 60. 20 SPS ODR, 50 ms Settling Time
Figure 63. 20 SPS ODR, 50 ms Settling Time at 50 Hz/60 Hz
Rev. B | Page 35 of 60
AD7177-2
Data Sheet
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–100
0
100
200
300
400
500
600
40
45
50
55
60
65
70
FREQUENCY (Hz)
FREQUENCY (Hz)
Figure 64. 16.667 SPS ODR, 60 ms Settling Time
Figure 65. 16.667 SPS ODR, 60 ms Settling Time at 50 Hz/60 Hz
Rev. B | Page 36 of 60
Data Sheet
AD7177-2
OPERATING MODES
The AD7177-2 has a number of operating modes that can be set
from the ADC mode register and interface mode register (see
Table 27 and Table 28). These modes are as follows and are
described in the following sections:
register. When the data-word has been read from the data register,
RDY
the DOUT/
pin goes high. The user can read this register
additional times, if required. However, the user must ensure that
the data register is not being accessed at the completion of the
next conversion; otherwise, the new conversion word is lost.
•
•
•
•
•
•
Continuous conversion mode
Continuous read mode
Single conversion mode
Standby mode
Power-down mode
Calibration modes (three modes)
When several channels are enabled, the ADC automatically
sequences through the enabled channels, performing one
conversion on each channel. When all channels have been
converted, the sequence starts again with the first channel. The
channels are converted in order from lowest enabled channel to
highest enabled channel. The data register is updated as soon as
CONTINUOUS CONVERSION MODE
RDY
each conversion is available. The
output pulses low each
time a conversion is available. The user can then read the
conversion while the ADC converts the next enabled channel.
Continuous conversion is the default power-up mode. The
RDY
AD7177-2 converts continuously, and the
register goes low each time a conversion is complete. If
RDY
bit in the status
CS
is low,
output also goes low when a conversion is complete. To
If the DATA_STAT bit in the interface mode register is set to 1,
the contents of the status register, along with the conversion data,
are output each time the data register is read. The status register
indicates the channel to which the conversion corresponds.
the
read a conversion, the user writes to the communications
register, indicating that the next operation is a read of the data
CS
0x44
0x44
DIN
DATA
DATA
DOUT/RDY
SCLK
Figure 66. Continuous Conversion Mode
Rev. B | Page 37 of 60
AD7177-2
Data Sheet
To enable continuous read mode, set the CONTREAD bit in the
interface mode register. When this bit is set, the only serial interface
operations possible are reads from the data register. To exit con-
tinuous read mode, issue a dummy read of the ADC data register
CONTINUOUS READ MODE
In continuous read mode, it is not required to write to the
communications register before reading ADC data; apply only
RDY
the required number of SCLK pulses after
indicate the end of a conversion. When the conversion is read,
RDY
goes low to
RDY
command (0x44) while the
output is low. Alternatively, apply
CS
a software reset, that is, 64 SCLK pulses with
= 0 and DIN =
returns high until the next conversion is available. In this
1. This resets the ADC and all register contents. These are the
only commands that the interface recognizes after it is placed in
continuous read mode. Hold DIN low in continuous read mode
until an instruction is to be written to the device.
mode, the data can be read only once. The user must also ensure
that the data-word is read before the next conversion is
complete. If the user has not read the conversion before the
completion of the next conversion or if insufficient serial clocks
are applied to the AD7177-2 to read the data-word, the serial
output register is reset shortly before the next conversion is
complete, and the new conversion is placed in the output serial
register. The ADC must be configured for continuous
conversion mode to use continuous read mode.
If multiple ADC channels are enabled, each channel is output
in turn, with the status bits being appended to the data if
DATA_STAT is set in the interface mode register. The status
register indicates the channel to which the conversion corresponds.
CS
0x02
0x0080
DIN
DATA
DATA
DATA
DOUT/RDY
SCLK
Figure 67. Continuous Read Mode
Rev. B | Page 38 of 60
Data Sheet
AD7177-2
output goes low. The ADC then selects the next channel and
SINGLE CONVERSION MODE
begins a conversion. The user can read the present conversion
while the next conversion is being performed. As soon as the next
conversion is complete, the data register is updated; therefore,
the user has a limited period in which to read the conversion.
When the ADC has performed a single conversion on each of
the selected channels, it returns to standby mode.
In single conversion mode, the AD7177-2 performs a single
conversion and is placed in standby mode after the conversion
RDY
is complete. The
of a conversion. When the data-word has been read from the
RDY
output goes low to indicate the completion
data register, the DOUT/
pin goes high. The data register
RDY
can be read several times, if required, even when the DOUT/
pin has gone high.
If the DATA_STAT bit in the interface mode register is set to 1,
the contents of the status register, along with the conversion, are
output each time the data register is read. The two LSBs of the
status register indicate the channel to which the conversion
corresponds.
If several channels are enabled, the ADC automatically sequences
through the enabled channels and performs a conversion on
RDY
each channel. When a conversion is started, the DOUT/ pin
goes high and remains high until a valid conversion is available
CS
RDY
and is low. As soon as the conversion is available, the
CS
0x01
0x8010
0x44
DIN
DATA
DOUT/RDY
SCLK
Figure 68. Single Conversion Mode
Rev. B | Page 39 of 60
AD7177-2
Data Sheet
STANDBY AND POWER-DOWN MODES
0.75×VIN
VREF
Data =
×223
−
(
Offset − 0x800000
)
×
In standby mode, most blocks are powered down. The LDOs
remain active so that registers maintain their contents. The
internal reference remains active if enabled, and the crystal
oscillator remains active if selected. To power down the
reference in standby mode, set the REF_EN bit in the ADC
mode register to 0. To power down the clock in standby mode,
set the CLOCKSEL bits in the ADC mode register to 00
(internal oscillator).
Gain
+ 0x800000
0x400000
To start a calibration, write the relevant value to the mode bits
RDY RDY
in the ADC mode register. The DOUT/
pin and the
bit in the status register go high when the calibration initiates.
When the calibration is complete, the contents of the correspond-
ing offset or gain register are updated, the
register is reset and the
low), and the AD7177-2 reverts to standby mode.
RDY
bit in the status
output pin returns low (if
In power-down mode, all blocks are powered down, including
the LDOs. All registers lose their contents, and the GPIOx
outputs are placed in three-state. To prevent accidental entry to
power-down mode, the ADC must first be placed in standby
mode. Exiting power-down mode requires 64 SCLK pulses with
RDY
CS
is
During an internal offset calibration, the selected positive
analog input pin is disconnected, and both modulator inputs
are connected internally to the selected negative analog input
pin. For this reason, it is necessary to ensure that the voltage on
the selected negative analog input pin does not exceed the
allowed limits and is free from excessive noise and interference.
CS
= 0 and DIN = 1, that is, a serial interface reset. A delay of
500 µs is recommended before issuing a subsequent serial
interface command to allow the LDO to power up.
Figure 15 shows the internal reference settling time after
returning from standby mode (setting REF_EN = 0 and then 1)
and returning from power-down.
System calibrations, however, expect the system zero-scale
(offset) and system full-scale (gain) voltages to be applied to the
ADC pins before initiating the calibration modes. As a result,
errors external to the ADC are removed.
CALIBRATION
The AD7177-2 allows a two-point calibration to be performed
to eliminate any offset and gain errors. Three calibration modes
eliminate these offset and gain errors on a per setup basis, as
follows:
From an operational point of view, treat a calibration like
another ADC conversion. An offset calibration, if required,
must always be performed before a full-scale calibration. Set the
RDY
system software to monitor the
bit in the status register or
output to determine the end of a calibration via a
•
•
•
Internal zero-scale calibration mode
System zero-scale calibration mode
System full-scale calibration mode
RDY
the
polling sequence or an interrupt-driven routine. All calibrations
require a time equal to the settling time of the selected filter and
output data rate to be completed.
There is no internal full-scale calibration mode because this is
calibrated in the factory at the time of production.
An internal offset calibration, system zero-scale calibration, and
system full-scale calibration can be performed at any output data
rate. Using lower output data rates results in better calibration
accuracy and is accurate for all output data rates. A new offset
calibration is required for a given channel if the reference source
for that channel is changed.
Only one channel can be active during calibration. After each
conversion, the ADC conversion result is scaled using the ADC
calibration registers before being written to the data register.
The default value of the offset register is 0x800000, and the
nominal value of the gain register is 0x555555. The calibration
range of the ADC gain is from 0.4 × VREF to 1.05 × VREF. The
following equations show the calculations that are used for
24-bit data output. In unipolar mode, the ideal relationship—
that is, not taking into account the ADC gain error and offset
error—is as follows:
The offset error is typically 40 µV and an offset calibration
reduces the offset error to the order of the noise. The gain error
is factory calibrated at ambient temperature. Following this
calibration, the gain error is typically 2.5 ppm of FSR.
The AD7177-2 provides the user with access to the on-chip
calibration registers, allowing the microprocessor to read the
calibration coefficients of the device and to write its own
calibration coefficients. A read or write of the offset and gain
registers can be performed at any time except during an internal
or self calibration.
0.75×VIN
VREF
Gain
0x400000
Data =
×223
−
(
Offset − 0x800000
)
×
×2
In bipolar mode, the ideal relationship—that is, not taking into
account the ADC gain error and offset error—is as follows:
Rev. B | Page 40 of 60
Data Sheet
AD7177-2
DIGITAL INTERFACE
The programmable functions of the AD7177-2 are controlled via
the SPI serial interface. The serial interface of the AD7177-2
For CRC checksum calculations during a write operation, the
following polynomial is always used:
CS
RDY
x8 + x2 + x + 1
consists of four signals: , DIN, SCLK, and DOUT/
. The
DIN input is used to transfer data into the on-chip registers, and
the DOUT output is used to access data from the on-chip
registers. SCLK is the serial clock input for the device, and all data
transfers (either on the DIN input or on the DOUT output) occur
with respect to the SCLK signal.
During read operations, the user can select between this
polynomial and a simpler exclusive OR (XOR) function. The
XOR function requires less time to process on the host
microcontroller than the polynomial-based checksum. The
CRC_EN bits in the interface mode register enable and disable
the checksum and allow the user to select between the
polynomial check and the simple XOR check.
RDY
The DOUT/
the output going low if
available in the data register. The
a read operation from the data register is complete. The
pin also functions as a data ready signal, with
CS
is low when a new data-word is
RDY
output is reset high when
RDY
The checksum is appended to the end of each read and write
transaction. The checksum calculation for the write transaction
is calculated using the 8-bit command word and the 8-bit to
24-bit data. For a read transaction, the checksum is calculated
using the command word and the 8-bit to 32-bit data output.
Figure 69 and Figure 70 show SPI write and read transactions,
respectively.
output also goes high before updating the data register to
indicate when not to read from the device to ensure that a data
read is not attempted while the register is being updated. Take
RDY
care to avoid reading from the data register when the
output is about to go low. The best method to ensure that no data
RDY
read occurs is to always monitor the
output; start reading
output goes low; and
ensure a sufficient SCLK rate, such that the read is complete
CS
8-BIT COMMAND
UP TO 24-BIT INPUT
8-BIT CRC
RDY
the data register as soon as the
CS
before the next conversion result.
is used to select a device. It
CS
DATA
CRC
DIN
can be used to decode the AD7177-2 in systems where several
components are connected to the serial bus.
SCLK
Figure 2 and Figure 3 show timing diagrams for interfacing to
CS
the AD7177-2 using
to decode the device. Figure 2 shows
Figure 69. SPI Write Transaction with CRC
the timing for a read operation from the AD7177-2, and Figure 3
shows the timing for a write operation to the AD7177-2. It is
possible to read from the data register several times even though
UP TO
8-BIT COMMAND
40-BIT OUTPUT
8-BIT CRC
CS
RDY
the
output returns high after the first read operation.
However, care must be taken to ensure that the read operations are
completed before the next output update occurs. In continuous
read mode, the data register can be read only once.
CMD
DIN
DOUT/
RDY
DATA
CRC
CS
The serial interface can operate in 3-wire mode by tying
low.
pins are used to
communicate with the AD7177-2. The end of the conversion
RDY
RDY
In this case, the SCLK, DIN, and DOUT/
SCLK
can also be monitored using the
bit in the status register.
CS
The AD7177-2 can be reset by writing 64 SCLKs with
= 0
Figure 70. SPI Read Transaction with CRC
and DIN = 1. A reset returns the interface to the state in which it
expects a write to the communications register. This operation
resets the contents of all registers to their power-on values.
Following a reset, allow a period of 500 µs before addressing the
serial interface.
If checksum protection is enabled when continuous read mode
is active, an implied read data command of 0x44 before every
data transmission must be accounted for when calculating the
checksum value. This implied read data command ensures a
nonzero checksum value even if the ADC data equals 0x000000.
CHECKSUM PROTECTION
The AD7177-2 has a checksum mode that can be used to
improve interface robustness. Using the checksum ensures that
only valid data is written to a register and allows data read from
a register to be validated. If an error occurs during a register
write, the CRC_ERROR bit is set in the status register. However,
to ensure that the register write is successful, read back the
register and verify the checksum.
Rev. B | Page 41 of 60
AD7177-2
Data Sheet
To generate the checksum, the data is left shifted by eight bits to
create a number ending in eight Logic 0s. The polynomial is
aligned so that its MSB is adjacent to the leftmost Logic 1 of the
data. An XOR function is applied to the data to produce a new,
shorter number. The polynomial is again aligned so that its MSB is
adjacent to the leftmost Logic 1 of the new result, and the proce-
dure is repeated. This process repeats until the original data is
reduced to a value less than the polynomial. This is the 8-bit
checksum.
CRC CALCULATION
Polynomial
The checksum, which is eight bits wide, is generated using the
polynomial
x8 + x2 + x + 1
Example of a Polynomial CRC Calculation—24-Bit Word: 0x654321 (Eight Command Bits and 16-Bit Data)
An example of generating the 8-bit checksum using the polynomial-based checksum is as follows:
Initial value
011001010100001100100001
01100101010000110010000100000000
left shifted eight bits
polynomial
x8 + x2 + x + 1
=
100000111
100100100000110010000100000000
100000111
XOR result
polynomial
XOR result
polynomial
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
XOR result
polynomial value
checksum = 0x86
100011000110010000100000000
100000111
11111110010000100000000
100000111
1111101110000100000000
100000111
111100000000100000000
100000111
11100111000100000000
100000111
1100100100100000000
100000111
100101010100000000
100000111
101101100000000
100000111
1101011000000
100000111
101010110000
100000111
1010001000
100000111
10000110
Rev. B | Page 42 of 60
Data Sheet
AD7177-2
XOR Calculation
The checksum, which is 8 bits wide, is generated by splitting the data into bytes and then performing an XOR of the bytes.
Example of an XOR Calculation—24-Bit Word: 0x654321 (Eight Command Bits and 16-Bit Data)
Using the previous example of a polynomial CRC calculation, divide the data into three bytes: 0x65, 0x43, and 0x21.
01100101
01000011
00100110
00100001
00000111
0x65
0x43
XOR result
0x21
CRC
Rev. B | Page 43 of 60
AD7177-2
Data Sheet
INTEGRATED FUNCTIONS
The AD7177-2 has integrated functions that improve the
usefulness of a number of applications as well as serve
diagnostic purposes in safety conscious applications.
The effect on the noise performance depends on the delay time
compared to the conversion time. It is possible to absorb the
delay only for output data rates less than 10 kSPS with the
exception of the following four rates, which cannot absorb any
delay: 397.5 SPS, 59.92 SPS, 49.96 SPS, and 16.66 SPS.
GENERAL-PURPOSE I/O
The AD7177-2 has two general-purpose digital input/output pins:
GPIO0 and GPIO1. They are enabled using the IP_EN0/IP_EN1
bits or the OP_EN0/OP_EN1 bits in the GPIOCON register. When
the GPIO0 or GPIO1 pin is enabled as an input, the logic level at
the pin is contained in the GP_DATA0 or GP_DATA1 bit, respec-
tively. When the GPIO0 or GPIO1 pin is enabled as an output, the
GP_DATA0 or GP_DATA1 bits, respectively, determine the logic
level output at the pin. The logic levels for these pins are
referenced to AVDD1 and AVSS; therefore, outputs have an
amplitude of 5 V.
24-BIT/32-BIT CONVERSIONS
By default, the AD7177-2 generates 24-bit conversions.
However, the width of the conversions can be increased to 32 bits.
Setting the WL32 bit in the interface mode register to 1 sets all
data conversions to 32 bits. Clearing this bit sets the width of
the data conversions to 24 bits. The WL32 bit affects the size of
the data register but does not affect the size of the offset or gain
registers.
If 32-bit data conversions are enabled at the same time that the
DATA_STAT bit is set, the ADC outputs 28 data bits and the
four channel bits of the status register for each data read.
SYNC ERROR
pin can also be used as a general-purpose
The
output. When the ERR_EN bits in the GPIOCON register are
SYNC ERROR
pin operates as a general-purpose
/
set to 11, the
/
DOUT_RESET
output. In this configuration, the ERR_DAT bit in the GPIOCON
register determines the logic level output at the pin. The logic level
for the pin is referenced to IOVDD and DGND.
RDY
The serial interface uses a shared DOUT/
pin. By default,
signal. During a data read, this pin
outputs the data from the register being read. After the read is
RDY
RDY
this pin outputs the
SYNC ERROR
pin, when set as general-
Both GPIOs and the
/
complete, the pin reverts to outputting the
signal after a
purpose outputs, have an active pull-up circuit.
short fixed period of time (t7). However, this time may be too
short for some microcontrollers and can be extended until the
EXTERNAL MULTIPLEXER CONTROL
CS
pin is brought high by setting the DOUT_RESET bit in the
If an external multiplexer is used to increase the channel count,
the multiplexer logic pins can be controlled via the AD7177-2
GPIOx pins. With the MUX_IO bit, the GPIOx timing is
controlled by the ADC; therefore, the channel change is
synchronized with the ADC, eliminating any need for external
synchronization.
CS
interface mode register to 1. This means that
to frame each read operation and compete the serial interface
transaction.
must be used
SYNCHRONIZATION
Normal Synchronization
DELAY
When the SYNC_EN bit in the GPIOCON register is set to 1,
It is possible to insert a programmable delay before the AD7177-2
begins to take samples. This delay allows an external amplifier
or multiplexer to settle and can alleviate the specification
requirements for the external amplifier or multiplexer. Eight
programmable settings, ranging from 0 µs to 1 ms, can be set
using the delay bits in the ADC mode register (Register 0x01,
Bits[10:8]).
SYNC ERROR
the
/
pin functions as a synchronization input.
SYNC
The
input lets the user reset the modulator and the
digital filter without affecting any of the setup conditions on the
device. This feature lets the user start to gather samples of the
SYNC
analog input from a known point, the rising edge of the
SYNC
input. The
input must be low for at least one master
clock cycle to ensure that synchronization occurs.
If a delay greater than 0 µs is selected and the HIDE_DELAY bit
in the ADC mode register is set to 0, this delay is added to the
conversion time, regardless of the selected output data rate.
If multiple AD7177-2 devices are operated from a common
master clock, they can be synchronized so that their analog
inputs are sampled simultaneously. This synchronization is
normally done after each AD7177-2 device has performed its
own calibration or has calibration coefficients loaded into its
When using the sinc5 + sinc1 filter, it is possible to hide this
delay such that the output data rate remains the same as the output
data rate without the delay enabled. If the HIDE_DELAY bit is
set to 1 and the selected delay is less than half of the conversion
time, the delay can be absorbed by reducing the number of
averages the digital filter performs, which keeps the conversion
time the same but can affect the noise performance.
SYNC
calibration registers. A falling edge on the
digital filter and the analog modulator and places the AD7177-2
SYNC
input resets the
into a consistent known state. While the
input is low, the
SYNC
AD7177-2 is maintained in this known state. On the
input rising edge, the modulator and filter are taken out of this
reset state, and on the next master clock edge, the device starts to
gather input samples again.
Rev. B | Page 44 of 60
Data Sheet
AD7177-2
The device is taken out of reset on the master clock falling edge
CRC_ERROR
SYNC
following the
input low to high transition. Therefore,
SYNC
If the CRC value that accompanies a write operation does not
correspond with the information sent, the CRC_ERROR flag is
set. The flag is reset as soon as the status register is explicitly read.
when multiple devices are being synchronized, take the
input high on the master clock rising edge to ensure that all
devices are released on the master clock falling edge. If the
REG_ERROR
SYNC
input is not taken high in sufficient time, a difference of
The REG_ERROR flag is used in conjunction with the
REG_CHECK bit in the interface mode register. When the
REG_CHECK bit is set, the AD7177-2 monitors the values in
the on-chip registers. If a bit changes, the REG_ERROR bit is
set. Therefore, for writes to the on-chip registers, set REG_
CHECK to 0. When the registers have been updated, the
REG_CHECK bit can be set to 1. The AD7177-2 calculates a
checksum of the on-chip registers. If one of the register values
has changed, the REG_ERROR bit is set. If an error is flagged,
the REG_CHECK bit must be set to 0 to clear the REG_ERROR
bit in the status register. The register check function does not
monitor the data register, status register, or interface mode
register.
one master clock cycle between the devices is possible; that is,
the instant at which conversions are available differs from
device to device by a maximum of one master clock cycle.
SYNC
The
mand for a single channel when in normal synchronization
SYNC
input can also be used as a start conversion com-
mode. In this mode, the rising edge of the
RDY
input starts a
output indicates
conversion, and the falling edge of the
when the conversion is complete. The settling time of the filter is
required for each data register update. After the conversion is
SYNC
complete, bring the
input low in preparation for the next
conversion start signal.
Alternate Synchronization
ERROR
Input/Output
When the SYNC_EN bit in the GPIOCON register is set to 0,
SYNC ERROR
pin functions as an error input/output pin or
a general-purpose output pin. The ERR_EN bits in the GPIOCON
register determine the function of the pin.
SYNC
In alternate synchronization mode, the
input operates as
a start conversion command when several channels of the
AD7177-2 are enabled. Setting the ALT_SYNC bit in the interface
mode register to 1 enables an alternate synchronization scheme.
the
/
SYNC
When the
conversion on the current channel, selects the next channel in
SYNC
input is taken low, the ADC completes the
SYNC ERROR
With ERR_EN is set to 10, the
ERROR
/
pin functions as
the sequence, and then waits until the
RDY
input is taken high
output goes low when
an open-drain error output,
. The three error bits in the
to commence the conversion. The
status register (ADC_ERROR, CRC_ERROR, and
REG_ERROR) are OR’ed, inverted, and mapped to the
the conversion is complete on the current channel, and the data
register is updated with the corresponding conversion. Therefore,
ERROR
ERROR
output. Therefore, the
output indicates that an error
SYNC
the
input does not interfere with the sampling on the
has occurred. The status register must be read to identify the
error source.
currently selected channel but allows the user to control the
instant at which the conversion begins on the next channel in
the sequence.
SYNC ERROR
When ERR_EN is set to 01, the
/
pin functions as
. The error output of another component
ERROR
ERROR
an error input,
can be connected to the AD7177-2
AD7177-2 indicates when an error occurs on either itself or the
ERROR
Alternate synchronization mode can be used only when several
channels are enabled. It is not recommended to use this mode
when a single channel is enabled.
input so that the
external component. The value on the
input is inverted
ERROR FLAGS
and OR’e d with the errors from the ADC conversion, and the
result is indicated via the ADC_ERROR bit in the status register.
The status register contains three error bits—ADC_ERROR,
CRC_ERROR, and REG_ERROR—that flag errors with the
ADC conversion, errors with the CRC check, and errors caused
ERROR
The value of the
in the status register.
input is reflected in the ERR_DAT bit
ERROR
by changes in the registers, respectively. In addition, the
output can indicate that an error has occurred.
ERROR
The
input/output is disabled when ERR_EN is set to 00.
SYNC ERROR
pin
When the ERR_EN bits are set to 11, the
operates as a general-purpose output.
/
ADC_ERROR
The ADC_ERROR bit in the status register flags any errors that
occur during the conversion process. The flag is set when an over-
range or underrange result is output from the ADC. The ADC
also outputs all 0s or all 1s when an undervoltage or overvoltage
occurs. This flag is reset only when the overvoltage or undervoltage
is removed. It is not reset by a read of the data register.
DATA_STAT
The contents of the status register can be appended to each con-
version on the AD7177-2. This function is useful if several
channels are enabled. Each time a conversion is output, the
contents of the status register are appended. The two LSBs of
the status register indicate to which channel the conversion
corresponds. In addition, the user can determine if any errors
are being flagged by the error bits. If 32-bit data conversions are
Rev. B | Page 45 of 60
AD7177-2
Data Sheet
enabled at the same time that the DATA_STAT bit is set, the
ADC outputs 28 data bits and the four channel bits of the status
register for each data read.
selected in the same way as an analog input channel. The
temperature sensor requires that the analog input buffers be
enabled on both analog inputs. If the buffers are not enabled,
selecting the temperature sensor as an input forces the buffers
to be enabled during the conversion.
IOSTRENGTH
The serial interface can operate with a power supply as low as
To use the temperature sensor, the first step is to calibrate the
device in a known temperature (25°C) and take a conversion as
a reference point. The temperature sensor has a nominal sensitivity
of 470 µV/K; the difference in this ideal slope and the slope
measured can be used to calibrate the temperature sensor. The
temperature sensor is specified with a 2°C typical accuracy
after calibration at 25°C. Calibrate the temperature as follows:
RDY
2 V. However, at this low voltage, the DOUT/
pin may not
have sufficient drive strength if there is moderate parasitic
capacitance on the board or the SCLK frequency is high. The
IOSTRENGTH bit in the interface mode register increases the
RDY
drive strength of the DOUT/
pin.
INTERNAL TEMPERATURE SENSOR
The AD7177-2 has an integrated temperature sensor. The
temperature sensor can be used as a guide for the ambient
temperature at which the device is operating. This can be used
for diagnostic purposes or as an indicator of when the applica-
tion circuit needs to rerun a calibration routine to take into
account a shift in operating temperature. The temperature
sensor is selected using the crosspoint multiplexer and is
Conversion Result
Temperature (°C) =
– 273.15
470 μV
Rev. B | Page 46 of 60
Data Sheet
AD7177-2
GROUNDING AND LAYOUT
The analog inputs and reference inputs are differential and,
therefore, most of the voltages in the analog modulator are
common-mode voltages. The high common-mode rejection of
the device removes common-mode noise on these inputs. The
analog and digital supplies to the AD7177-2 are independent
and connected to separate pins to minimize coupling between the
analog and digital sections of the device. The digital filter
provides rejection of broadband noise on the power supplies,
except at integer multiples of the master clock frequency.
possible to provide low impedance paths and reduce glitches on
the power supply line. Shield fast switching signals like clocks
with digital ground to prevent radiating noise to other sections
of the board and never run clock signals near the analog inputs.
Avoid crossover of digital and analog signals. Run traces on
opposite sides of the board at right angles to each other. This
technique reduces the effects of feedthrough on the board. A
microstrip technique is by far the best method but is not always
possible with a double sided board.
The digital filter also removes noise from the analog and
reference inputs, provided that these noise sources do not
saturate the analog modulator. As a result, the AD7177-2 is
more immune to noise interference than a conventional high
resolution converter. However, because the resolution of the
AD7177-2 is high and the noise levels from the converter are so
low, take care with regard to grounding and layout.
Good decoupling is important when using high resolution ADCs.
The AD7177-2 has three power supply pins—AVDD1, AVDD2,
and IOVDD. The AVDD1 and AVDD2 pins are referenced to
AVSS, and the IOVDD pin is referenced to DGND. Decouple
AVDD1 and AVDD2 with a 10 µF capacitor in parallel with a
0.1 µF capacitor to AVSS on each pin. Place the 0.1 µF capacitor
as close as possible to the device on each supply, ideally right up
against the device. Decouple IOVDD with a 10 µF capacitor in
parallel with a 0.1 µF capacitor to DGND. Decouple all analog
inputs to AVSS. If an external reference is used, decouple the
REF+ and REF− pins to AVSS.
The PCB that houses the ADC must be designed such that the
analog and digital sections are separated and confined to
certain areas of the board. A minimum etch technique is
generally best for ground planes because it results in the best
shielding.
The AD7177-2 also has two on-board LDO regulators—one
that regulates the AVDD2 supply and one that regulates the
IOVDD supply. For the REGCAPA pin, it is recommended that
1 µF and 0.1 µF capacitors to AVSS be used. Similarly, for the
REGCAPD pin, it is recommended that 1 µF and 0.1 µF capaci-
tors to DGND be used.
In any layout, the user must consider the flow of currents in the
system, ensuring that the paths for all return currents are as close as
possible to the paths the currents took to reach their destinations.
Avoid running digital lines under the device because this
couples noise onto the die and allows the analog ground plane
to run under the AD7177-2 to prevent noise coupling. The
power supply lines to the AD7177-2 must use as wide a trace as
If using the AD7177-2 for split supply operation, a separate
plane must be used for AVSS.
Rev. B | Page 47 of 60
AD7177-2
Data Sheet
REGISTER SUMMARY
Table 24. Register Summary
Reg. Name
0x00 COMMS
0x00 STATUS
Bits
[7:0]
[7:0]
Bit 7
WEN
RDY
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
RA
Bit 1
Bit 0
Reset
0x00
0x80
RW
W
W
R/
HIDE_DELAY
CHANNEL
R
0x01 ADCMODE
[15:8]
[7:0]
REF_EN
SING_CYC
MODE
RESERVED
DELAY
RESERVED
0x8000
RW
RW
R
RESERVED
CLOCKSEL
0x02 IFMODE
[15:8]
[7:0]
RESERVED
ALT_SYNC
REGISTER_CHECK[23:16]
IOSTRENGTH
RESERVED
DOUT_RESET 0x0000
RESERVED
CONTREAD
0x03 REGCHECK
[23:16]
[15:8]
[7:0]
0x000000
REGISTER_CHECK[15:8]
REGISTER_CHECK[7:0]
DATA[31:17]
0x04 DATA
[31:17]
[23:16]
[15:8]
[7:0]
0x000000
R
DATA[23:16]
DATA[15:8]
DATA[7:0]
0x06 GPIOCON
0x07 ID
[15:8]
[7:0]
RESERVED
MUX_IO
SYNC_EN
ERR_EN
ERR_DAT
0x0800
0x4FDX
0x8001
0x0001
0x0001
0x0001
RW
R
RESERVED
GP_DATA0
[15:8]
[7:0]
ID[15:8]
ID[7:0]
0x10 CH0
[15:8]
[7:0]
CH_EN0
CH_EN1
CH_EN2
CH_EN3
RESERVED
AINPOS0[2:0]
RESERVED
AINPOS1[2:0]
RESERVED
AINPOS2[2:0]
RESERVED
AINPOS3[2:0]
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
SETUP_SEL0
SETUP_SEL1
SETUP_SEL2
SETUP_SEL3
RESERVED
AINNEG0
RESERVED
AINNEG1
RESERVED
AINNEG2
RESERVED
AINNEG3
REFBUF0-
AINPOS0[4:3]
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
0x11 CH1
[15:8]
[7:0]
AINPOS1[4:3]
AINPOS2[4:3]
AINPOS3[4:3]
0x12 CH2
[15:8]
[7:0]
0x13 CH3
[15:8]
[7:0]
0x20 SETUPCON0
0x21 SETUPCON1
0x22 SETUPCON2
0x23 SETUPCON3
0x28 FILTCON0
0x29 FILTCON1
0x2A FILTCON2
0x2B FILTCON3
[15:8]
[7:0]
BI_UNIPOLAR0
REF_SEL0
BI_UNIPOLAR1
REF_SEL1
BI_UNIPOLAR2
REF_SEL2
BI_UNIPOLAR3
REF_SEL3
RESERVED
ORDER0
REFBUF0+
REFBUF1+
REFBUF2+
REFBUF3+
AINBUF0+
AINBUF1+
AINBUF0− 0x1320
AINBUF1− 0x1320
AINBUF2− 0x1320
AINBUF3− 0x1320
0x0507
BURNOUT_EN0
BURNOUT_EN1
BURNOUT_EN2
RESERVED
[15:8]
[7:0]
REFBUF1−
RESERVED
[15:8]
[7:0]
REFBUF2−
AINBUF2+
RESERVED
[15:8]
[7:0]
REFBUF3−
AINBUF3+
BURNOUT_EN3
SINC3_MAP0
RESERVED
RESERVED
[15:8]
[7:0]
ENHFILTEN0
ENHFILTEN1
ENHFILTEN2
ENHFILTEN3
ENHFILT0
ENHFILT1
ENHFILT2
ENHFILT3
ODR0
ODR1
ODR2
ODR3
[15:8]
[7:0]
SINC3_MAP1
RESERVED
RESERVED
RESERVED
RESERVED
0x0507
ORDER1
ORDER2
ORDER3
[15:8]
[7:0]
SINC3_MAP2
RESERVED
0x0507
[15:8]
[7:0]
SINC3_MAP3
RESERVED
0x0507
0x30 OFFSET0
0x31 OFFSET1
0x32 OFFSET2
0x33 OFFSET3
0x38 GAIN0
0x39 GAIN1
0x3A GAIN2
0x3B GAIN3
[23:0]
[23:0]
[23:0]
[23:0]
[23:0]
[23:0]
[23:0]
[23:0]
OFFSET0[23:0]
0x800000 RW
0x800000 RW
0x800000 RW
0x800000 RW
0x5XXXX0 RW
0x5XXXX0 RW
0x5XXXX0 RW
0x5XXXX0 RW
OFFSET1[23:0]
OFFSET2[23:0]
OFFSET3[23:0]
GAIN0[23:0]
GAIN1[23:0]
GAIN2[23:0]
GAIN3[23:0]
Rev. B | Page 48 of 60
Data Sheet
AD7177-2
REGISTER DETAILS
COMMUNICATIONS REGISTER
Address: 0x00, Reset: 0x00, Name: COMMS
All access to the on-chip registers must start with a write to the communications register. This write determines what register is accessed
next and whether that operation is a write or a read.
Table 25. Bit Descriptions for COMMS
Bits
Bit Name
Settings
Description
Reset
0x0
Access
W
7
WEN
This bit must be low to begin communications with the ADC.
6
R/W
This bit determines if the command is a read or write operation.
0x0
W
0
1
Write command
Read command
[5:0]
RA
The register address bits determine which register is to be read from or
written to as part of the current communication.
0x00
W
000000 Status register
000001 ADC mode register
000010 Interface mode register
000011 Register checksum register
000100 Data register
000110 GPIO configuration register
000111 ID register
010000 Channel 0 register
010001 Channel 1 register
010010 Channel 2 register
010011 Channel 3 register
100000 Setup Configuration 0 register
100001 Setup Configuration 1 register
100010 Setup Configuration 2 register
100011 Setup Configuration 3 register
101000 Filter Configuration 0 register
101001 Filter Configuration 1 register
101010 Filter Configuration 2 register
101011 Filter Configuration 3 register
110000 Offset 0 register
110001 Offset 1 register
110010 Offset 2 register
110011 Offset 3 register
111000 Gain 0 register
111001 Gain 1 register
111010 Gain 2 register
111011 Gain 3 register
Rev. B | Page 49 of 60
AD7177-2
Data Sheet
STATUS REGISTER
Address: 0x00, Reset: 0x80, Name: STATUS
The status register is an 8-bit register that contains ADC and serial interface status information. It can optionally be appended to the data
register by setting the DATA_STAT bit in the interface mode register.
Table 26. Bit Descriptions for STATUS
Bits
Bit Name
Settings
Description
Reset
Access
7
RDY
The status of RDY is output to the DOUT/RDYpin whenever CS is low and a 0x1
register is not being read. This bit goes low when the ADC has written a
new result to the data register. In ADC calibration modes, this bit goes low
when the ADC has written the calibration result. RDY is brought high
automatically by a read of the data register.
R
0
1
New data result available
Awaiting new data result
6
ADC_ERROR
This bit by default indicates if an ADC overrange or underrange has
occurred. The ADC result is clamped to 0xFFFFFF for overrange errors and
0x000000 for underrange errors. This bit is updated when the ADC result is
written and is cleared at the next update after removing the overrange or
underrange condition.
0x0
R
0
1
No error
Error
5
4
CRC_ERROR
REG_ERROR
This bit indicates if a CRC error has taken place during a register write. For
register reads, the host microcontroller determines if a CRC error has
occurred. This bit is cleared by a read of this register.
No error
CRC error
0x0
0x0
R
R
0
1
This bit indicates if the content of one of the internal registers has
changed from the value calculated when the register integrity check was
activated. The check is activated by setting the REG_CHECK bit in the
interface mode register. This bit is cleared by clearing the REG_CHECK bit.
0
1
No error
Error
[3:2]
[1:0]
RESERVED
CHANNEL
These bits are reserved.
0x0
0x0
R
R
These bits indicate which channel was active for the ADC conversion
whose result is currently in the data register. This may be different from
the channel currently being converted. The mapping is a direct map from
the channel register; therefore, Channel 0 results in 0x0 and Channel 3
results in 0x3.
00 Channel 0
01 Channel 1
10 Channel 2
11 Channel 3
Rev. B | Page 50 of 60
Data Sheet
AD7177-2
ADC MODE REGISTER
Address: 0x01, Reset: 0x8000, Name: ADCMODE
The ADC mode register controls the operating mode of the ADC and the master clock selection. A write to the ADC mode register resets
the filter and the bits and starts a new conversion or calibration.
RDY
Table 27. Bit Descriptions for ADCMODE
Bits
Bit Name
Settings
Description
Reset
Access
15
REF_EN
Enables internal reference and outputs a buffered 2.5 V to the REFOUT pin. 0x1
RW
0
1
Disabled
Enabled
14
13
HIDE_DELAY
SING_CYC
If a programmable delay is set using the delay bits, this bit allows the
delay to be hidden by absorbing the delay into the conversion time for
selected data rates with the sinc5 + sinc1 filter. See the Delay section for
more information.
Enabled
Disabled
0x0
RW
RW
0
1
This bit can be used when only a single channel is active to set the ADC to 0x0
only output at the settled filter data rate.
0
1
Disabled
Enabled
[12:11] RESERVED
These bits are reserved; set these bits to 0.
0x0
R
[10:8]
DELAY
These bits allow a programmable delay to be added after a channel switch 0x0
to allow the settling of external circuitry before the ADC starts processing
its input.
RW
000 0 μs
001 4 μs
010 16 μs
011 40 μs
100 100 μs
101 200 μs
110 500 μs
111 1 ms
7
RESERVED
MODE
This bit is reserved; set this bit to 0.
0x0
0x0
R
[6:4]
These bits control the operating mode of the ADC. See the Operating
Modes section for more information.
RW
000 Continuous conversion mode
001 Single conversion mode
010 Standby mode
011 Power-down mode
100 Internal offset calibration
110 System offset calibration
111 System gain calibration
[3:2]
[1:0]
CLOCKSEL
RESERVED
These bits are used to select the ADC clock source. Selecting the internal
oscillator also enables the internal oscillator.
00 Internal oscillator
01 Internal oscillator output on the XTAL2/CLKIO pin
10 External clock input on the XTAL2/CLKIO pin
11 External crystal on the XTAL1 and XTAL2/CLKIO pins
These bits are reserved; set these bits to 0.
0x0
0x0
RW
R
Rev. B | Page 51 of 60
AD7177-2
Data Sheet
INTERFACE MODE REGISTER
Address: 0x02, Reset: 0x0000, Name: IFMODE
The interface mode register configures various serial interface options.
Table 28. Bit Descriptions for IFMODE
Bits
Bit Name
Settings
Description
Reset
0x0
Access
R
[15:13] RESERVED
These bits are reserved; set these bits to 0.
12
11
ALT_SYNC
This bit enables a different behavior of the SYNC/ERROR pin to allow the
use of SYNC/ERROR as a control for conversions when cycling channels
(see the description of the SYNC_EN bit in the GPIO Configuration Register
section for details).
Disabled
Enabled
0x0
RW
0
1
IOSTRENGTH
This bit controls the drive strength of the DOUT/RDY pin. Set this bit
when reading from the serial interface at high speed with a low IOVDD
supply and moderate capacitance.
0x0
RW
0
1
Disabled (default)
Enabled
[10:9]
8
RESERVED
These bits are reserved; set these bits to 0.
0x0
0x0
R
DOUT_RESET
See the DOUT_RESET section for more information.
RW
0
1
Disabled
Enabled
7
6
CONTREAD
DATA_STAT
This bit enables continuous read mode of the ADC data register. The ADC 0x0
must be configured in continuous conversion mode to use continuous
read mode. For more details, see the Operating Modes section.
Disabled
Enabled
RW
RW
0
1
This bit enables the status register to be appended to the data register
when read so that channel and status information are transmitted with
the data. This is the only way to be sure that the channel bits read from
the status register correspond to the data in the data register.
0x0
0
1
Disabled
Enabled
5
REG_CHECK
This bit enables a register integrity checker, which can be used to
monitor any change in the value of the user registers. To use this feature,
configure all other registers as desired with this bit cleared. Then write to this
register to set the REG_CHECK bit to 1. If the contents of any of the
registers change, the REG_ERROR bit is set in the status register. To clear
the error, set the REG_CHECK bit to 0. Neither the interface mode register
nor the ADC data or status registers are included in the registers that are
checked. If a register must have a new value written, this bit must first be
cleared; otherwise, an error is flagged when the new register contents
are written.
0x0
RW
0
1
Disabled
Enabled
4
RESERVED
CRC_EN
This bit is reserved; set this bit to 0.
0x0
R
[3:2]
These bits enable CRC protection of register reads/writes. CRC increases
the number of bytes in a serial interface transfer by one. See the CRC
Calculation section for more details.
0x00
RW
00 Disabled
01 XOR checksum enabled for register read transactions; register writes still
use CRC with these bits set
10 CRC checksum enabled for read and write transactions
Rev. B | Page 52 of 60
Data Sheet
AD7177-2
Bits
Bit Name
Settings
Description
Reset
Access
1
WL32
This bit changes the ADC data register length. The ADC is not reset by a
write to the interface mode register; therefore, the ADC result is not
changed to the correct word length immediately after writing to these
bits. The first new ADC result is correct.
0x0
RW
0
1
24-bit data
32-bit data
0
RESERVED
This bit is reserved; set this bit to 0.
0x0
R
REGISTER CHECK
Address: 0x03, Reset: 0x000000, Name: REGCHECK
The register check register is a 24-bit checksum calculated by exclusively OR'ing the contents of the user registers. The REG_CHECK bit
in the interface mode register must be set for this to operate; otherwise, the register reads 0.
Table 29. Bit Descriptions for REGCHECK
Bits
Bit Name
Settings
Description
Reset
Access
[23:0]
REGISTER_CHECK
This register contains the 24-bit checksum of user registers when the
REG_CHECK bit is set in the interface mode register.
0x000000
R
DATA REGISTER
Address: 0x04, Reset: 0x000000, Name: DATA
The data register contains the ADC conversion result. The encoding is offset binary, or it can be changed to unipolar by the
RDY RDY
output high if it is
BI_UNIPOLARx bits in the setup configuration registers. Reading the data register brings the
bit and the
output is brought high, it is not possible to know if another
RDY
low. The ADC result can be read multiple times; however, because the
ADC result is imminent. After the command to read the ADC register is received, the ADC does not write a new result into the data
register.
Table 30. Bit Descriptions for DATA
Bits
Bit Name
Settings
Description
Reset
Access
[31:0]
DATA
This register contains the ADC conversion result. The size of this register
is determined by the WL32 bits in the interface mode register.
0x000000
R
Rev. B | Page 53 of 60
AD7177-2
Data Sheet
GPIO CONFIGURATION REGISTER
Address: 0x06, Reset: 0x0800, Name: GPIOCON
The GPIO configuration register controls the general-purpose I/O pins of the ADC.
Table 31. Bit Descriptions for GPIOCON
Bits
Bit Name
Settings Description
Reset
0x0
Access
R
[15:13] RESERVED
These bits are reserved; set these bits to 0.
12
11
MUX_IO
This bit allows the ADC to control an external multiplexer, using GPIO0/GPIO1 in sync
with the internal channel sequencing. The analog input pins used for a channel
can still be selected on a per channel basis. Therefore, it is possible to have a
4-channel multiplexer in front of AIN0/AIN1 and another in front of AIN2/AIN3, giving a
total of eight differential channels with the AD7177-2. However, only four channels at
a time can be automatically sequenced. A delay can be inserted after switching an
external multiplexer (see the DELAY bits in the ADC Mode Register section).
0x0
RW
SYNC_EN
This bit enables the SYNC/ERROR pin as a sync input. When the pin is low, this
holds the ADC and filter in reset until the SYNC/ERROR pin goes high. An
alternative operation of the SYNC/ERROR pin is available when the ALT_SYNC bit
in the interface mode register is set. This mode only works when multiple channels
are enabled. In this case, a low on the SYNC/ERROR pin does not immediately reset
the filter/modulator. Instead, if the SYNC/ERROR pin is low when the channel is
due to be switched, the modulator and filter are prevented from starting a new
conversion. Bringing SYNC/ERROR high begins the next conversion. This alterna-
tive sync mode allows SYNC/ERROR to be used while cycling through channels.
0x1
RW
0
1
Disabled.
Enabled.
[10:9]
ERR_EN
These bits enable the SYNC/ERROR pin as an error input/output.
0x0
RW
00 Disabled.
01 SYNC/ERROR is an error input. The (inverted) readback state is OR'ed with other
error sources and is available in the ADC_ERROR bit in the status register. The SYNC/
ERROR pin state can also be read from the ERR_DAT bit in this register.
10 SYNC/ERROR is an open-drain error output. The status register error bits are OR'ed,
inverted, and mapped to the SYNC/ERROR pin. The SYNC/ERROR pins of multiple
devices can be wired together to a common pull-up resistor so that an error on
any device can be observed.
11 SYNC/ERROR is a general-purpose output. The status of the pin is controlled by the
ERR_DAT bit in this register. This output is referenced between IOVDD and DGND,
as opposed to the AVDD1 and AVSS levels used by the general-purpose I/O pins.
The SYNC/ERROR pin has an active pull-up in this case.
8
ERR_DAT
This bit determines the logic level at the SYNC/ERROR pin if the pin is enabled as a
general-purpose output. This bit reflects the readback status of the pin if the pin is
enabled as an input.
0x0
RW
[7:6]
5
RESERVED
IP_EN1
These bits are reserved; set these bits to 0.
0x0
0x0
R
This bit turns GPIO1 into an input. Inputs are referenced to AVDD1 or AVSS.
RW
0
1
Disabled.
Enabled.
4
3
2
IP_EN0
This bit turns GPIO0 into an input. Inputs are referenced to AVDD1 or AVSS.
Disabled.
Enabled.
0x0
RW
RW
RW
0
1
OP_EN1
OP_EN0
This bit turns GPIO1 into an output. Outputs are referenced between AVDD1 and AVSS. 0x0
Disabled.
Enabled.
0
1
This bit turns GPIO0 into an output. Outputs are referenced between AVDD1 and AVSS. 0x0
0
1
Disabled.
Enabled.
1
0
GP_DATA1
GP_DATA0
This bit is the readback or write data for GPIO1.
This bit is the readback or write data for GPIO0.
0x0
0x0
RW
RW
Rev. B | Page 54 of 60
Data Sheet
AD7177-2
ID REGISTER
Address: 0x07, Reset: 0x4FDX, Name: ID
The ID register returns a 16-bit ID. For the AD7177-2, this ID is 0x4FDX.
Table 32. Bit Descriptions for ID
Bits
Bit Name
Settings
Description
Reset
0x4FDX
Access
[15:0]
ID
The ID register returns a 16-bit ID code that is specific to the ADC.
R
0x4FDX AD7177-2
CHANNEL REGISTER 0
Address: 0x10, Reset: 0x8001, Name: CH0
The channel registers are 16-bit registers used to select which channels are currently active, which inputs are selected for each channel,
and which setup is used to configure the ADC for that channel.
Table 33. Bit Descriptions for CH0
Bits
Bit Name
Settings
Description
Reset
Access
15
CH_EN0
This bit enables Channel 0. If more than one channel is enabled, the ADC
automatically sequences between them.
0x1
RW
0
1
Disabled
Enabled (default)
14
RESERVED
This bit is reserved; set this bit to 0.
0x0
0x0
R
[13:12] SETUP_SEL0
These bits identify which of the four setups is used to configure the ADC
for this channel. A setup comprises a set of four registers: setup configuration
register, filter configuration register, offset register, and gain register. All
channels can use the same setup, in which case the same 2-bit value must be
written to these bits on all active channels, or up to four channels can be
configured differently.
RW
00 Setup 0
01 Setup 1
10 Setup 2
11 Setup 3
[11:10] RESERVED
[9:5] AINPOS0
These bits are reserved; set these bits to 0.
0x0
0x0
R
These bits select which input is connected to the positive input of the
ADC for this channel.
RW
00000 AIN0 (default)
00001 AIN1
00010 AIN2
00011 AIN3
00100 AIN4
10001 Temperature sensor+
10010 Temperature sensor−
10011 ((AVDD1 − AVSS)/5)+ (analog input buffers must be enabled)
10100 ((AVDD1 − AVSS)/5)− (analog input buffers must be enabled)
10101 REF+
10110 REF−
Rev. B | Page 55 of 60
AD7177-2
Data Sheet
Bits
Bit Name
AINNEG0
Settings
Description
Reset
Access
[4:0]
These bits select which input is connected to the negative input of the
ADC for this channel.
0x1
RW
00000 AIN0
00001 AIN1 (default)
00010 AIN2
00011 AIN3
00100 AIN4
10001 Temperature sensor+
10010 Temperature sensor−
10011 ((AVDD1 − AVSS)/5)+
10100 ((AVDD1 − AVSS)/5)−
10101 REF+
10110 REF−
CHANNEL REGISTER 1 TO CHANNEL REGISTER 3
Address: 0x11 to 0x13, Reset: 0x0001, Name: CH1 to CH3
The remaining three channel registers share the same layout as Channel Register 0.
Table 34. CH1 to CH3 Register Map
Reg.
Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reset
RW
0x11
CH1
[15:8]
[7:0]
CH_EN1
RESERVED
AINPOS1[2:0]
SETUP_SEL1
RESERVED
AINPOS1[4:3]
0x0001
0x0001
0x0001
RW
AINNEG1
RESERVED
AINNEG2
RESERVED
AINNEG3
0x12
0x13
CH2
CH3
[15:8]
[7:0]
CH_EN2
CH_EN3
RESERVED
SETUP_SEL2
SETUP_SEL3
AINPOS2[4:3]
AINPOS3[4:3]
RW
RW
AINPOS2[2:0]
[15:8]
[7:0]
RESERVED
AINPOS3[2:0]
Rev. B | Page 56 of 60
Data Sheet
AD7177-2
SETUP CONFIGURATION REGISTER 0
Address: 0x20, Reset: 0x1320, Name: SETUPCON0
The setup configuration registers are 16-bit registers that configure the reference selection, input buffers, and output coding of the ADC.
Table 35. Bit Descriptions for SETUPCON0
Bits
Bit Name
Settings
Description
Reset
0x0
Access
R
[15:13] RESERVED
These bits are reserved; set these bits to 0.
This bit sets the output coding of the ADC for Setup 0.
Unipolar coded output
Bipolar coded output (offset binary)
This bit enables or disables the REF+ input buffer.
REF+ buffer disabled
12
11
10
9
BI_UNIPOLAR0
0x1
RW
0
1
REFBUF0+
REFBUF0−
AINBUF0+
AINBUF0−
BURNOUT_EN0
0x0
0x0
0x1
0x1
0x00
RW
RW
RW
RW
R
0
1
REF+ buffer enabled
This bit enables or disables the REF− input buffer.
REF− buffer disabled
REF− buffer enabled
0
1
This bit enables or disables the AIN+ input buffer.
AIN+ buffer disabled
AIN+ buffer enabled
0
1
8
This bit enables or disables the AIN− input buffer.
AIN− buffer disabled
AIN− buffer enabled
0
1
7
This bit enables a 10 μA current source on the positive analog input
selected and a 10 μA current sink on the negative analog input selected.
The burnout currents are useful in diagnosis of an open wire, whereby the
ADC result goes to full scale. Enabling the burnout currents during
measurement results in an offset voltage on the ADC. This means the
strategy for diagnosing an open wire operates best by turning on the
burnout currents at intervals, before or after precision measurements.
6
RESERVED
REF_SEL0
These bits are reserved; set these bits to 0.
0x00
0x2
R
[5:4]
These bits allow the user to select the reference source for ADC
conversion on Setup 0.
RW
00 External reference.
10 Internal 2.5 V reference. This must also be enabled in the ADC mode register.
11 AVDD1 − AVSS. This can be used to as a diagnostic to validate other
reference values.
[3:0]
RESERVED
These bits are reserved; set these bits to 0.
0x0
R
SETUP CONFIGURATION REGISTER 1 TO SETUP CONFIGURATION REGISTER 3
Address: 0x21 to 0x23, Reset: 0x1320, Name: SETUPCON1 to SETUPCON3
The remaining three setup configuration registers share the same layout as Setup Configuration Register 0.
Table 36. SETUPCON1 to SETUPCON3 Register Map
Reg.
Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reset
RW
0x21
SETUPCON1
[15:8]
[7:0]
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
BI_UNIPOLAR1
REFBUF1+
REFBUF1−
AINBUF1+
AINBUF1−
AINBUF2−
AINBUF3−
0x1320
0x1320
0x1320
RW
BURNOUT_EN1
BURNOUT_EN2
BURNOUT_EN3
REF_SEL1
BI_UNIPOLAR2
REF_SEL2
BI_UNIPOLAR3
REF_SEL3
RESERVED
0x22
0x23
SETUPCON2
SETUPCON3
[15:8]
[7:0]
REFBUF2+
REFBUF3+
REFBUF2−
AINBUF2+
RW
RW
RESERVED
[15:8]
[7:0]
REFBUF3−
AINBUF3+
RESERVED
Rev. B | Page 57 of 60
AD7177-2
Data Sheet
FILTER CONFIGURATION REGISTER 0
Address: 0x28, Reset: 0x0507, Name: FILTCON0
The filter configuration registers are 16-bit registers that configure the ADC data rate and filter options. Writing to any of these registers
resets any active ADC conversion and restarts converting at the first channel in the sequence.
Table 37. Bit Descriptions for FILTCON0
Bits
Bit Name
Settings
Description
Reset
Access
15
SINC3_MAP0
If this bit is set, the mapping of the filter register changes to directly
program the decimation rate of the sinc3 filter for Setup 0. All other
options are eliminated. This allows fine tuning of the output data rate
and filter notch for rejection of specific frequencies. The data rate when
on a single channel equals fMOD/(32 × FILTCON0[14:0]).
0x0
RW
[14:12] RESERVED
These bits are reserved; set these bits to 0.
0x0
0x0
R
11
ENHFILTEN0
This bit enables various postfilters for enhanced 50 Hz/60 Hz rejection
for Setup 0. The ORDER0 bits must be set to 00 to select the sinc5 +
sinc1 filter for this to work.
RW
0
1
Disabled
Enabled
[10:8]
ENHFILT0
These bits select between various postfilters for enhanced 50 Hz/60 Hz
rejection for Setup 0.
0x5
RW
010 27 SPS, 47 dB rejection, 36.7 ms settling
011 25 SPS, 62 dB rejection, 40 ms settling
101 20 SPS, 85 dB rejection, 50 ms settling
110 16.67 SPS, 92 dB rejection, 60 ms settling
This bit is reserved; set this bit to 0.
7
RESERVED
ORDER0
0x0
0x0
R
[6:5]
These bits control the order of the digital filter that processes the
modulator data for Setup 0.
RW
00 Sinc5 + sinc1 (default)
11 Sinc3
[4:0]
ODR0
These bits control the output data rate of the ADC and, therefore, the
settling time and noise for Setup 0. Rates shown are for the sinc5 + sinc
1 filter. See Table 19 to Table 22.
0x07
RW
00000 to Reserved
00110
00111 10,000 SPS
01000 5000 SPS
01001 2500 SPS
01010 1000 SPS
01011 500 SPS
01100 397.5 SPS
01101 200 SPS
01110 100 SPS
01111 59.92 SPS
10000 49.96 SPS
10001 20 SPS
10010 16.66 SPS
10011 10 SPS
10100 5 SPS
Rev. B | Page 58 of 60
Data Sheet
AD7177-2
FILTER CONFIGURATION REGISTER 1 TO FILTER CONFIGURATION REGISTER 3
Address: 0x29 to 0x2B, Reset: 0x0507, Name: FILTCON1 to FILTCON3
The remaining three filter configuration registers share the same layout as Filter Configuration Register 0.
Table 38. FILTCON1 to FILTCON3 Register Map
Reg.
Name
Bits
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
ODR1
Bit 1
ENHFILT1
Bit 0
Reset
RW
0x29
FILTCON1
[15:8]
[7:0]
SINC3_MAP1
RESERVED
RESERVED
ENHFILTEN1
0x0507
RW
ORDER1
RESERVED
ORDER2
RESERVED
ORDER3
0x2A
0x2B
FILTCON2
FILTCON3
[15:8]
[7:0]
SINC3_MAP2
RESERVED
ENHFILTEN2
ENHFILTEN3
ENHFILT2
ENHFILT3
0x0507
0x0507
RW
RW
ODR2
ODR3
[15:8]
[7:0]
SINC3_MAP3
RESERVED
OFFSET REGISTER 0
Address: 0x30, Reset: 0x800000, Name: OFFSET0
The offset (zero-scale) registers are 24-bit registers that can be used to compensate for any offset error in the ADC or in the system.
Table 39. Bit Descriptions for OFFSET0
Bits
Bit Name
Settings
Description
Reset
Access
[23:0]
OFFSET0
Offset calibration coefficient for Setup 0.
0x800000 RW
OFFSET REGISTER 1 TO OFFSET REGISTER 3
Address: 0x31 to 0x33, Reset: 0x800000, Name: OFFSET1 to OFFSET3
The remaining three offset registers share the same layout as Offset Register 0.
Table 40. OFFSET1 to OFFSET3 Register Map
Reg. Name
Bits
Reset
RW
0x31 OFFSET1
0x32 OFFSET2
0x33 OFFSET3
OFFSET1[23:0]
OFFSET2[23:0]
OFFSET3[23:0]
0x800000 RW
0x800000 RW
0x800000 RW
GAIN REGISTER 0
Address: 0x38, Reset: 0x5XXXX0, Name: GAIN0
The gain (full-scale) registers are 24-bit registers that can be used to compensate for any gain error in the ADC or in the system.
Table 41. Bit Descriptions for GAIN0
Bits
Bit Name
Settings
Description
Reset
Access
[23:0]
GAIN0
Gain calibration coefficient for Setup 0.
0x5XXXX0 RW
GAIN REGISTER 1 TO GAIN REGISTER 3
Address: 0x39 to 0x3B, Reset: 0x5XXXX0, Name: GAIN1 to GAIN3
The remaining three gain registers share the same layout as Gain Register 0.
Table 42. GAIN1 to GAIN3 Register Map
Reg. Name
0x39 GAIN1
0x3A GAIN2
0x3B GAIN3
Bits
Reset
RW
GAIN1[23:0]
GAIN2[23:0]
GAIN3[23:0]
0x5XXXX0 RW
0x5XXXX0 RW
0x5XXXX0 RW
Rev. B | Page 59 of 60
AD7177-2
Data Sheet
OUTLINE DIMENSIONS
7.90
7.80
7.70
24
13
12
4.50
4.40
4.30
6.40 BSC
1
PIN 1
0.65
BSC
1.20
MAX
0.15
0.05
0.75
0.60
0.45
8°
0°
0.30
0.19
0.20
0.09
SEATING
PLANE
0.10 COPLANARITY
COMPLIANT TO JEDEC STANDARDS MO-153-AD
Figure 71. 24-Lead Thin Shrink Small Outline Package [TSSOP]
(RU-24)
Dimensions shown in millimeters
ORDERING GUIDE
Model1
Temperature Range
Package Description
Package Option
AD7177-2BRUZ
AD7177-2BRUZ-RL7
−40°C to +105°C
−40°C to +105°C
24-Lead Thin Shrink Small Outline Package [TSSOP]
24-Lead Thin Shrink Small Outline Package [TSSOP]
RU-24
RU-24
1 Z = RoHS Compliant Part.
©2015–2016 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D12912-0-3/16(B)
Rev. B | Page 60 of 60
相关型号:
AD7177-2BRUZ-RL7
32-Bit, 10 kSPS, Sigma-Delta ADC with 100 µs Settling and True Rail-to-Rail Buffers
ADI
AD7191BRUZ
1-CH 24-BIT DELTA-SIGMA ADC, SERIAL ACCESS, PDSO24, ROHS COMPLIANT, PLASTIC, MO-153AD, TSSOP-24
ROCHESTER
©2020 ICPDF网 联系我们和版权申明