IC PARALLEL, 8 BITS INPUT LOADING, 8-BIT DAC, CDIP18, 0.300 INCH, SIDE BRAZED, CERAMIC, DIP-18, Digital to Analog Converter;
AD7224TD
型号: AD7224TD
厂家: ADI    ADI
描述:

IC PARALLEL, 8 BITS INPUT LOADING, 8-BIT DAC, CDIP18, 0.300 INCH, SIDE BRAZED, CERAMIC, DIP-18, Digital to Analog Converter

CD 输入元件 转换器
文件: 总13页 (文件大小:67K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
REVISIONS  
LTR  
A
DESCRIPTION  
Drawing updated to reflect current requirements. - ro  
DATE (YR-MO-DA)  
03-01-28  
APPROVED  
R. MONNIN  
REV  
SHEET  
REV  
SHEET  
REV STATUS  
OF SHEETS  
PMIC N/A  
REV  
A
1
A
2
A
3
A
4
A
5
A
6
A
7
A
8
A
9
A
A
A
SHEET  
10  
11  
12  
PREPARED BY  
SANDRA ROONEY  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216  
CHECKED BY  
SANDRA ROONEY  
STANDARD  
MICROCIRCUIT  
DRAWING  
http://www.dscc.dla.mil  
APPROVED BY  
MICHAEL A. FRYE  
THIS DRAWING IS AVAILABLE  
FOR USE BY ALL  
MICROCIRCUIT, LINEAR, CMOS 8-BIT DAC WITH  
OUTPUT AMPLIFIER, MONOLITHIC SILICON  
DEPARTMENTS  
AND AGENCIES OF THE  
DEPARTMENT OF DEFENSE  
DRAWING APPROVAL DATE  
94-04-29  
AMSC N/A  
REVISION LEVEL  
A
SIZE  
A
CAGE CODE  
5962-90908  
67268  
SHEET  
1
OF  
12  
DSCC FORM 2233  
APR 97  
5962-E186-03  
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.  
1. SCOPE  
1.1 Scope. This drawing documents two product assurance class levels consisting of high reliability (device classes Q and  
M) and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the  
Part or Identifying Number (PIN). When available, a choice of Radiation Hardness Assurance (RHA) levels are reflected in the  
PIN.  
1.2 PIN. The PIN is as shown in the following example:  
5962  
-
90908  
01  
M
V
X
Federal  
stock class  
designator  
\
RHA  
designator  
(see 1.2.1)  
Device  
type  
(see 1.2.2)  
Device  
class  
designator  
(see 1.2.3)  
Case  
outline  
(see 1.2.4)  
Lead  
finish  
(see 1.2.5)  
/
\/  
Drawing number  
1.2.1 RHA designator. Device classes Q and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and  
are marked with the appropriate RHA designator. Device class M RHA marked devices meet the MIL-PRF-38535, appendix A  
specified RHA levels and are marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.  
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:  
Device type  
01  
Generic number  
AD7224U  
Circuit function  
8-bit DAC with output amplifier  
1.2.3 Device class designator. The device class designator is a single letter identifying the product assurance level as  
follows:  
Device class  
M
Device requirements documentation  
Vendor self-certification to the requirements for MIL-STD-883 compliant, non-  
JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A  
Q or V  
Certification and qualification to MIL-PRF-38535  
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:  
Outline letter  
Descriptive designator  
Terminals  
Package style  
V
2
GDIP1-T18 or CDIP2-T18  
CQCC1-N20  
18  
20  
Dual-in-line  
Square leadless chip carrier  
1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38535 for device classes Q and V or MIL-PRF-38535,  
appendix A for device class M.  
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
2
DSCC FORM 2234  
APR 97  
1.3 Absolute maximum ratings. 1/  
V
DD  
V
DD  
V
SS  
V
SS  
V
DD  
to AGND .................................................................................. -0.3 V dc, +17 V dc  
to DGND .................................................................................. -0.3 V dc, +17 V dc  
to AGND ................................................................................... -7 V dc, V  
to DGND ................................................................................... -7 V dc, V  
DD  
DD  
to V  
..................................................................................... -0.3 V dc, +24 V dc  
SS  
AGND to DGND ................................................................................ -0.3 V dc, V  
Digital input voltage to DGND .......................................................... -0.3 V dc, V  
DD  
DD  
DD  
V
V
to AGND ............................................................................... -0.3 V dc, V  
to AGND ............................................................................... V , V  
SS DD  
REF  
OUT  
Power dissipation (P ) .................................................................... 450 mW 2/  
D
Storage temperature range ............................................................... -65°C to +160°C  
Lead temperature (soldering, 10 seconds) ...................................... +300°C  
Thermal resistance, junction-to-case (θJC) ...................................... See MIL-STD-1835  
Thermal resistance, junction-to-ambient (θJA):  
Case outline V .............................................................................. 120°C/W  
Case outline 2 .............................................................................. 120°C/W  
1.4 Recommended operating conditions.  
Operating temperature range ........................................................... -55°C to +125°C  
2. APPLICABLE DOCUMENTS  
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a  
part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in  
the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the  
solicitation.  
SPECIFICATION  
DEPARTMENT OF DEFENSE  
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.  
STANDARDS  
DEPARTMENT OF DEFENSE  
MIL-STD-883  
-
Test Method Standard Microcircuits.  
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.  
HANDBOOKS  
DEPARTMENT OF DEFENSE  
MIL-HDBK-103 - List of Standard Microcircuit Drawings.  
MIL-HDBK-780 - Standard Microcircuit Drawings.  
(Unless otherwise indicated, copies of the specification, standards, and handbooks are available from the Standardization  
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)  
______  
1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the  
maximum levels may degrade performance and affect reliability.  
2/ Derate linearly above T = +75°C at 6 mW/°C.  
A
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
3
DSCC FORM 2234  
APR 97  
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text  
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a  
specific exemption has been obtained.  
3. REQUIREMENTS  
3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with  
MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The  
modification in the QM plan shall not affect the form, fit, or function as described herein. The individual item requirements for  
device class M shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified  
herein.  
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified  
in MIL-PRF-38535 and herein for device classes Q and V or MIL-PRF-38535, appendix A and herein for device class M.  
3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein.  
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1.  
3.2.3 Truth table. The truth table shall be as specified on figure 2.  
3.2.4 Timing waveforms. The timing waveforms shall be as specified on figure 3.  
3.3 Electrical performance characteristics and post irradiation parameter limits. Unless otherwise specified herein, the  
electrical performance characteristics and post irradiation parameter limits are as specified in table I and shall apply over the  
full ambient operating temperature range.  
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical  
tests for each subgroup are defined in table I.  
3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's PIN may also be  
marked as listed in MIL-HDBK-103. For packages where marking of the entire SMD PIN number is not feasible due to space  
limitations, the manufacturer has the option of not marking the "5962-" on the device. For RHA product using this option, the  
RHA designator shall still be marked. Marking for device classes Q and V shall be in accordance with MIL-PRF-38535.  
Marking for device class M shall be in accordance with MIL-PRF-38535, appendix A.  
3.5.1 Certification/compliance mark. The certification mark for device classes Q and V shall be a "QML" or "Q" as required in  
MIL-PRF-38535. The compliance mark for device class M shall be a "C" as required in MIL-PRF-38535, appendix A.  
3.6 Certificate of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML-38535  
listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). For device class M, a certificate of  
compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see  
6.6.2 herein). The certificate of compliance submitted to DSCC-VA prior to listing as an approved source of supply for this  
drawing shall affirm that the manufacturer's product meets, for device classes Q and V, the requirements of MIL-PRF-38535  
and herein or for device class M, the requirements of MIL-PRF-38535, appendix A and herein.  
3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 or for  
device class M in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing.  
3.8 Notification of change for device class M. For device class M, notification to DSCC-VA of change of product (see 6.2  
herein) involving devices acquired to this drawing is required for any change as defined in MIL-PRF-38535, appendix A.  
3.9 Verification and review for device class M. For device class M, DSCC, DSCC's agent, and the acquiring activity retain  
the option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made  
available onshore at the option of the reviewer.  
3.10 Microcircuit group assignment for device class M. Device class M devices covered by this drawing shall be in  
microcircuit group number 80 (see MIL-PRF-38535, appendix A).  
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
4
DSCC FORM 2234  
APR 97  
TABLE I. Electrical performance characteristics.  
Conditions 1/  
-55°C T +125°C  
Group A  
subgroups  
Device  
type  
Limits  
Max  
Unit  
A
Test  
Symbol  
unless otherwise specified  
Min  
Resolution  
RES  
RA  
1,2,3  
1
01  
01  
8
Bits  
Relative accuracy  
LSB  
1
V
V
V
V
= +14 V, V = -5 V,  
SS  
DD  
2,3  
1
0.5  
2
= +10 V  
REF  
Total unadjusted error  
01  
LSB  
E
T
= +14 V, V = -5 V,  
SS  
DD  
2,3  
1,2,3  
1
1
= +10 V  
REF  
Differential nonlinearity  
Full scale error  
DNL  
Guaranteed monotonic  
to 8 bits  
01  
01  
LSB  
LSB  
1
1.5  
1.0  
30  
A
E
V
V
V
= +14 V, V = -5 V,  
DD SS  
2,3  
1
= +10 V  
REF  
Zero code error  
01  
mV  
A
ZCE  
= +16.5 V,  
DD  
11.4 V and 14 V,  
2,3  
20  
20  
V
V
V
V
V
= -5 V,  
SS  
= V  
– 4 V  
REF  
DD  
Full scale temp  
coefficient  
2/  
1,2,3  
01  
ppm/°C  
dA /  
= 14 V to 16.5 V,  
E
DD  
d
= +10 V  
T
REF  
Reference input resistance  
Voltage output slew rate  
1,2,3  
4
01  
01  
01  
01  
8
kΩ  
R
= 14 V  
DD  
IN  
2.5  
100  
V/µs  
pF  
t
SR  
Reference input  
capacitance  
Occurs when DAC is  
loaded with all 1’s  
4
C
IN  
Digital input leakage  
current  
1,2,3  
1
µA  
V
I
V
V
V
V
V
V
= 0 V or V  
,
IN  
IN  
DD  
= 16.8 V  
= 11.4 V,  
DD  
DD  
REF  
Digital input high voltage  
7,8  
7,8  
01  
01  
2.4  
V
V
IH  
= V  
– 4 V  
DD  
Digital input low voltage  
0.8  
V
= 11.4 V,  
IL  
DD  
= V  
– 4 V  
REF  
DD  
See footnotes at end of table.  
SIZE  
STANDARD  
MICROCIRCUIT DRAWING  
5962-90908  
A
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
5
DSCC FORM 2234  
APR 97  
TABLE I. Electrical performance characteristics – Continued.  
Conditions 1/  
-55°C T +125°C  
Group A  
subgroups  
Device  
type  
Limits  
Max  
Unit  
A
Test  
Symbol  
unless otherwise specified  
Min  
Positive power supply  
current  
Output unloaded:  
1
01  
01  
4
6
3
5
5
mA  
I
DD  
SS  
V
IN  
= V or V ,  
IL IH  
2,3  
1
V
V
= 16.5 V, V = -5.5 V,  
SS  
DD  
= 12.5 V  
REF  
Negative power supply  
current  
Output unloaded:  
mA  
I
V
IN  
= V or V ,  
IL IH  
2,3  
V
V
= 16.5 V, V = -5.5 V,  
SS  
DD  
= 12.5 V  
REF  
Voltage output settling  
time  
2/ 3/  
9,10,11  
9,10,11  
9,10,11  
9,10,11  
9,10,11  
9,10,11  
9,10,11  
01  
01  
01  
01  
01  
01  
01  
µs  
ns  
ns  
ns  
ns  
ns  
ns  
t
t
t
t
t
t
t
SL  
positive full-scale change  
2/  
Chip select / load DAC  
pulse width  
200  
200  
0
LD  
Write / reset pulse width  
2/  
2/  
2/  
2/  
2/  
WR  
CS  
CH  
DS  
DH  
Chip select / load DAC  
to write setup time  
Chip select / load DAC  
to write hold time  
Data valid to write  
setup time  
0
100  
10  
Data valid to write  
hold time  
1/  
V
DD  
= +11.4 V to 16.5 V; V = -5 V 10%; A  
= D  
= 0 V; V  
= +2 V to (V  
– 4 V) unless otherwise  
DO  
SS  
GND  
GND  
REF  
specified.  
2/ Guaranteed, if not tested, to the limits specified in table I herein.  
3/  
V
REF  
= +10 V; settling time to 0.5 LSB.  
SIZE  
STANDARD  
MICROCIRCUIT DRAWING  
5962-90908  
A
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
6
DSCC FORM 2234  
APR 97  
Device type  
01  
Case outlines  
V
2
Terminal  
number  
1
Terminal symbol  
NC  
V
SS  
2
3
V
V
SS  
OUT  
V
V
OUT  
REF  
4
AGND  
DGND  
DB7 (MSB)  
DB6  
V
REF  
5
AGND  
DGND  
DB7 (MSB)  
DB6  
6
7
8
DB5  
9
DB4  
DB5  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
DB3  
DB4  
DB2  
NC  
DB1  
DB3  
DB0 (LSB)  
DB2  
DB1  
CS  
WR  
DB0 (LSB)  
LDAC  
RESET  
CS  
WR  
V
DD  
LDAC  
RESET  
---  
---  
V
DD  
NC = No connection  
FIGURE 1. Terminal connections.  
SIZE  
STANDARD  
MICROCIRCUIT DRAWING  
5962-90908  
A
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
7
DSCC FORM 2234  
APR 97  
Function  
RESET  
LDAC  
WR  
L
CS  
L
H
H
H
H
H
H
H
L
L
X
H
H
H
L
Both registers are transparent  
Both registers are latched  
Both registers are latched  
Input register transparent  
Input register latched  
H
X
L
X
H
L
L
L
H
H
X
H
L
DAC register transparent  
DAC register latched  
L
X
H
L
X
H
L
Both registers loaded with all zeros  
Both registers latched with all zeros  
and output remains at zero  
Both registers are transparent and  
output follows input data  
H = High state, L = Low state, X = Don’t care  
FIGURE 2. Truth table.  
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
8
DSCC FORM 2234  
APR 97  
NOTES:  
1. All input signal rise and fall times measured from 10 % to 90 % of V . t = t = 20 ns over V range.  
DD  
DD  
r
f
2. Timing measurement reference level is : ( V  
+ V  
) / 2.  
INH  
INL  
FIGURE 3. Timing waveforms.  
SIZE  
STANDARD  
MICROCIRCUIT DRAWING  
5962-90908  
A
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
9
DSCC FORM 2234  
APR 97  
4. QUALITY ASSURANCE PROVISIONS  
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with  
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan  
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be  
in accordance with MIL-PRF-38535, appendix A.  
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted  
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in  
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.  
4.2.1 Additional criteria for device class M.  
a. Burn-in test, method 1015 of MIL-STD-883.  
(1) Test condition B . The test circuit shall be maintained by the manufacturer under document revision level control  
and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the  
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test  
method 1015.  
(2) T = +125°C, minimum.  
A
b. Interim and final electrical test parameters shall be as specified in table II herein.  
4.2.2 Additional criteria for device classes Q and V.  
a. The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the  
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under  
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with  
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall  
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test  
method 1015 of MIL-STD-883.  
b. Interim and final electrical test parameters shall be as specified in table II herein.  
c. Additional screening for device class V beyond the requirements of device class Q shall be as specified in  
MIL-PRF-38535, appendix B.  
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in  
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for  
groups A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).  
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with  
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified herein. Quality conformance inspection for  
device class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed  
for device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections  
(see 4.4.1 through 4.4.4).  
4.4.1 Group A inspection.  
a. Tests shall be as specified in table II herein.  
b. Subgroups 5 and 6 in table I, method 5005 of MIL-STD-883 shall be omitted.  
c. Subgroup 4 (C and T measurements) shall be measured only for the initial test and after process or design  
IN  
SR  
changes which may affect them.  
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
10  
DSCC FORM 2234  
APR 97  
TABLE II. Electrical test requirements.  
Subgroups  
Test requirements  
Subgroups  
(in accordance with  
(in accordance with  
MIL-STD-883,  
MIL-PRF-38535, table III)  
method 5005, table I)  
Device  
class M  
1
Device  
class Q  
Device  
class V  
Interim electrical  
1
1
parameters (see 4.2)  
Final electrical  
parameters (see 4.2)  
Group A test  
requirements (see 4.4)  
Group C end-point electrical  
parameters (see 4.4)  
Group D end-point electrical  
parameters (see 4.4)  
Group E end-point electrical  
parameters (see 4.4)  
1,2,3, 1/ 2/  
7,8,9,10,11  
1,2,3,4, 2/  
7,8,9,10,11  
1
1,2,3, 1/ 2/  
7,8,9,10,11  
1,2,3,4, 2/  
7,8,9,10,11  
1
1,2,3, 1/ 2/  
7,8,9,10,11  
1,2,3,4, 2/  
7,8,9,10,11  
1
1
1
1
---  
---  
---  
1/ PDA applies to subgroup 1.  
2/ Subgroups 9, 10, and 11 guaranteed to the limits specified in table I if not tested.  
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table II herein.  
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:  
a. Test condition B. The test circuit shall be maintained by the manufacturer under document revision level control and  
shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs,  
outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1005 of  
MIL-STD-883.  
b. T = +125°C, minimum.  
A
c. Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.  
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature,  
or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The  
test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with  
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify  
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1005 of  
MIL-STD-883.  
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table II herein.  
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
11  
DSCC FORM 2234  
APR 97  
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness  
assured (see 3.5 herein).  
a. End-point electrical parameters shall be as specified in table II herein.  
b. For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as  
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to  
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All  
device classes must meet the post irradiation end-point electrical parameter limits as defined in table I at T = +25°C  
A
5°C, after exposure, to the subgroups specified in table II herein.  
c. When specified in the purchase order or contract, a copy of the RHA delta limits shall be supplied.  
5. PACKAGING  
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device  
classes Q and V or MIL-PRF-38535, appendix A for device class M.  
6. NOTES  
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications  
(original equipment), design applications, and logistics purposes.  
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor  
prepared specification or drawing.  
6.1.2 Substitutability. Device class Q devices will replace device class M devices.  
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for  
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.  
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus when a system  
application requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users  
and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering  
microelectronic devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544.  
6.4 Comments. Comments on this drawing should be directed to DSCC-VA , Columbus, Ohio 43216-5000, or telephone  
(614) 692-0547.  
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in  
MIL-PRF-38535 and MIL-HDBK-1331.  
6.6 Sources of supply.  
6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535.  
The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DSCC-VA and have agreed to  
this drawing.  
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103.  
The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been  
submitted to and accepted by DSCC-VA.  
SIZE  
STANDARD  
5962-90908  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43216-5000  
REVISION LEVEL  
SHEET  
A
12  
DSCC FORM 2234  
APR 97  
STANDARD MICROCIRCUIT DRAWING BULLETIN  
DATE: 03-01-28  
Approved sources of supply for SMD 5962-90908 are listed below for immediate acquisition information only and  
shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be  
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a  
certificate of compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next  
dated revision of MIL-HDBK-103 and QML-38535.  
Standard  
microcircuit drawing  
PIN 1/  
Vendor  
CAGE  
number  
24355  
Vendor  
similar  
PIN 2/  
5962-9090801MVA  
AD7224UQ/883B  
5962-9090801M2A  
24355  
AD7224UE/883B  
1/ The lead finish shown for each PIN representing  
a hermetic package is the most readily available  
from the manufacturer listed for that part. If the  
desired lead finish is not listed contact the vendor  
to determine its availability.  
2/ Caution. Do not use this number for item acquisition.  
Items acquired to this number may not satisfy the  
performance requirements of this drawing.  
Vendor CAGE  
number  
Vendor name  
and address  
24355  
Analog Devices  
Route 1 Industrial Park  
P.O. Box 9106  
Norwood, MA 02062  
Point of contact: Bay F-1  
Raheen Ind. Estate  
Limerick, Ireland  
The information contained herein is disseminated for convenience only and the  
Government assumes no liability whatsoever for any inaccuracies in the  
information bulletin.  

相关型号:

AD7224TD/883B

IC IC,D/A CONVERTER,SINGLE,8-BIT,BICMOS,DIP,18PIN, Digital to Analog Converter
ADI

AD7224TE

LC2MOS 8-Bit DAC with Output Amplifiers
ADI

AD7224TE/883B

PARALLEL, 8 BITS INPUT LOADING, 8-BIT DAC, CQCC20, CERAMIC, LCC-20
ADI

AD7224TQ

LC2MOS 8-Bit DAC with Output Amplifiers
ADI

AD7224TQ/883B

PARALLEL, 8 BITS INPUT LOADING, 8-BIT DAC, CDIP18, CERDIP-18
ADI

AD7224UD

IC PARALLEL, 8 BITS INPUT LOADING, 8-BIT DAC, CDIP18, 0.300 INCH, SIDE BRAZED, CERAMIC, DIP-18, Digital to Analog Converter
ADI

AD7224UD/883B

IC IC,D/A CONVERTER,SINGLE,8-BIT,BICMOS,DIP,18PIN, Digital to Analog Converter
ADI

AD7224UE

LC2MOS 8-Bit DAC with Output Amplifiers
ADI

AD7224UE/883B

IC PARALLEL, 8 BITS INPUT LOADING, 8-BIT DAC, CQCC20, CERAMIC, LCC-20, Digital to Analog Converter
ADI