HMC600LP4 [ADI]
RF Detector 50MHz to 4000MHz 12dBm 24-Pin QFN EP T/R;型号: | HMC600LP4 |
厂家: | ADI |
描述: | RF Detector 50MHz to 4000MHz 12dBm 24-Pin QFN EP T/R 电信 电信集成电路 |
文件: | 总8页 (文件大小:503K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Typical Applications
Features
The HMC600LP4 / HMC600LP4E is ideal for IF and
RF applications in:
Wide Dynamic Range: up to 75 dB
Flexible Supply Voltage: +2.7V to +5.5V
Power-Down Mode
• Cellular/PCS/3G
• WiMAX, WiBro & Fixed Wireless
• Power Monitoring & Control Circuitry
• Receiver Signal Strength Indication (RSSI)
• Automatic Gain & Power Control
Excellent Stability over Temperature
Compact 4x4mm Leadless SMT Package
General Description
Functional Diagram
12
The HMC600LP4(E) Logarithmic Detector/Controller
converts RF signals at its input, to a proportional DC
voltage at its output. The HMC600LP4(E) employs
a successive compression topology which delivers
extremely high dynamic range and conversion accuracy
over a wide input frequency range. As the input power
is increased, successive amplifiers move into saturation
one by one creating an accurate approximation of the
logarithm function. The output of a series of square law
detectors is summed, converted into voltage domain
and buffered to drive the LOGOUT output. For detection
mode, the LOGOUT pin is shorted to the VSET input,
and will provide a nominal logarithmic slope of 19mV/dB
and an intercept of -95 dBm. The HMC600LP4(E) can
also be used in the controller mode where an external
voltage is applied to the VSET pin, to create an AGC or
APC feedback loop.
[1]
Electrical Specifications, TA = +25C, PWD = 0V, Vcc1, Vcc2 = +3.3V
Parameter
Typ.
Typ.
100
74
Typ.
500
74
Typ.
900
74
Typ.
1900
70
Typ.
2500
66
Typ.
3500
51
Typ.
4000
48
Units
MHz
dB
Input Frequency
50
3 dB Dynamic Range
3 dB Dynamic Range Center
1 dB Dynamic Range
74
-30
64
-30
64
-30
64
-30.5
65
-31.0
62
-31.0
59
-27
-23.5
41
dBm
dB
44
Output Slope
19.6
-96
-2.7
19.5
-96
-2.8
19.4
-96
-3.6
19.2
-96
19.1
-95
19.5
-93
21.0
-79
22.3
-72
mV/dB
dBm
mdB/°C
Output Intercept
Temperature Sensitivity @ -10 dBm Input [2]
-4.8
-6.9
-7.4
-8.3
-12.9
[1] Detector mode measurements; LOGOUT (Pin 17) is shorted to VSET (Pin 16).
[2] Measured from T = -40C to T = +85C
A
A
Parameter
Conditions
Min.
Typ.
10
Max.
Units
dB
RF Input (INP)
Return Loss
F = 50 - 4000 MHz, Zo = 50Ω, See plot
LOGOUT Interface
Open Loop Impedance
Current Drive (Source)
16
kΩ
0.4
mA
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 2
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Electrical Specifications, (continued)
Parameter
Conditions
Min.
0
Typ.
2.25
Max.
Units
mA
V
Current Drive (Sink)
For 1% change in the output voltage
Output Voltage Range
Vcc -0.13
Small Signal Response Time (10% to 90%)
Pin = -60 to -57 dBm
50
ns
Large Signal Response Time
( 0.5 dB Settling)
Pin = No Signal to 0 dBm
150
ns
Output Rise Time
From 0% to 90%
Fin = 100 MHz
90
<2
ns
Ripple
mVpp
VSET Interface
Input Impedance
30
0.6 to 1.9
78
kΩ
V
Input Voltage Range
Low Frequency Gain
VSET to LOGOUT
dB
kHz
12
Open Loop Corner Frequency
Power Down (PWD) Interface
Voltage Range for Normal Mode
Voltage Range for Shutdown Mode
Threshold Voltage
1.6
0
0.2 x Vcc
Vcc
V
V
0.8 x Vcc
Vcc/2
1
V
Power-up Response Time
Power-Down Response Time
Power Supply (Vcc1, Vcc2)
Operating Voltage Range
Supply Current in Normal Mode
Supply Current in Power Down Mode
50% PWD to 0.5 dB Settling of LOGOUT
50% PWD to 10% Icc
μs
μs
2.5
2.7
5.5
36
V
Vcc = +3.3V, PWD = 0V
Vcc = +3.3V, PWD = Vcc
29
1
mA
mA
Test Conditions
Parameter
Vcc1, Vcc2
Input Zo
TA
Condition
+3.3V
50Ω
+25C
Fin
900 MHz
INN Port connected to ground through a 1000pF capacitor
LOGOUT Voltage & Error
LOGOUT Voltage & Error
vs. Input Power, Fin = 100 MHz
vs. Input Power, Fin = 50 MHz
2
2
5
5
Ideal
Ideal
LOGOUT +25 C
1.6
LOGOUT +25 C
1.6
3
3
LOGOUT +85 C
LOGOUT -40 C
LOGOUT +85 C
LOGOUT -40 C
1.2
0.8
0.4
1.2
0.8
1
1
-1
-3
-1
-3
-5
ERR +25 C
ERR +85 C
0.4
ERR -40 C
ERR +25 C
ERR +85 C
ERR -40 C
0
-75
0
-75
-5
5
-65
-55
-45
-35
-25
-15
-5
-65
-55
-45
-35
-25
-15
-5
5
INPUT POWER (dBm)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
rights of third parties that may result from its use. Specifications subject to change without notice. No
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 3
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Voltage & Error
LOGOUT Voltage & Error
vs. Input Power, Fin = 500 MHz
vs. Input Power, Fin = 900 MHz
2
2
5
5
Ideal
Ideal
LOGOUT +25 C
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
LOGOUT +85 C
LOGOUT -40 C
1.6
1.2
0.8
0.4
0
1.6
1.2
0.8
0.4
0
3
3
1
1
-1
-3
-5
-1
-3
-5
ERR +25 C
ERR +85 C
ERR -40 C
ERR +25 C
ERR +85 C
ERR -40 C
12
-75
-65
-55
-45
-35
-25
-15
-5
5
5
5
-75
-65
-55
-45
-35
-25
-15
-5
5
5
5
INPUT POWER (dBm)
INPUT POWER (dBm)
LOGOUT Voltage & Error
vs. Input Power, Fin = 1900 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 2500 MHz
2
2
5
5
Ideal
Ideal
LOGOUT +25 C
1.6
LOGOUT +25 C
1.6
3
3
LOGOUT +85 C
LOGOUT -40 C
LOGOUT +85 C
LOGOUT -40 C
1.2
0.8
1.2
0.8
0.4
1
1
-1
-3
-5
-1
-3
-5
0.4
ERR +25 C
ERR +85 C
ERR -40 C
ERR +25 C
ERR +85 C
ERR -40 C
0
-75
0
-75
-65
-55
-45
-35
-25
-15
-5
-65
-55
-45
-35
-25
-15
-5
INPUT POWER (dBm)
INPUT POWER (dBm)
LOGOUT Voltage & Error
LOGOUT Voltage & Error
vs. Input Power, Fin = 4000 MHz
vs. Input Power, Fin = 3500 MHz
2
2
5
5
Ideal
Ideal
LOGOUT +25 C
LOGOUT +25 C
1.6
1.6
3
3
LOGOUT +85 C
LOGOUT +85 C
LOGOUT -40 C
LOGOUT -40 C
1.2
1.2
0.8
0.4
1
1
0.8
0.4
-1
-3
-5
-1
-3
-5
ERR +25 C
ERR +25 C
ERR +85 C
ERR -40 C
ERR +85 C
ERR -40 C
0
-65
0
-65
-55
-45
-35
-25
-15
-5
-55
-45
-35
-25
-15
-5
INPUT POWER (dBm)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
rights of third parties that may result from its use. Specifications subject to change without notice. No
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 4
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Slope vs. Frequency,
LOGOUT Slope vs. Supply Voltage,
Vcc = 3.3V
T = +25C
A
25
25
24
23
22
21
20
19
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
24
23
22
21
20
19
+25 C
+85 C
-40 C
18
0
18
12
1000
2000
FREQUENCY (MHz)
3000
4000
4000
5
2.5
3
3.5
4
4.5
5
5.5
5.5
5
Vcc (V)
LOGOUT Intercept vs. Frequency,
Vcc = +3.3V
LOGOUT Intercept vs. Bias Voltage
T = +25C
A
-50
-50
-60
-70
-80
-90
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
-60
+25 C
+85 C
-40 C
-70
-80
-90
-100
-100
2.5
0
1000
2000
FREQUENCY (MHz)
3000
3
3.5
4
4.5
5
Vcc (V)
LOGOUT Error vs. Input Power,
Normalized[2], Fin = 1900 MHz
Input Return Loss
2
0
-5
-10
-15
-20
-25
-30
-35
+85 C
-40 C
1
0
-1
-2
+25 C
+85 C
-40 C
-70
-55
-40
-25
-10
0
1
2
3
4
INPUT POWER (dBm)
FREQUENCY (GHz)
[1] Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
[2] This data is relative to the room temperature performance of the HMC600LP4
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 5
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Voltage vs. Input Power
Absolute Maximum Ratings
and Frequency, T = +25C
A
2
Vcc1, Vcc2
0V to +5.5V
0V to +5.5V
0V to +5.5V
3 mA
PWD
50 MHz
VSET Input Voltage
LOGOUT Output Current
RF Input Power
Junction Temperature
900 MHz
1900 MHz
3500 MHz
1.5
4000 MHz
+12 dBm
125 °C
Continuous Pdiss (T = 85°C)
(Derate 7.95 mW/°C above 85°C)
0.32 Watts
126 °C/W
1
Thermal Resistance (Rth)
(junction to lead)
Storage Temperature
Operating Temperature
ESD Sensitivity (HBM)
-65 to +150 °C
-40 to +85 °C
Class 1C
0.5
12
-75
-65
-55
-45
-35
-25
-15
-5
5
INPUT POWER (dBm)
ELECTROSTATIC SENSITIVE DEVICE
OBSERVE HANDLING PRECAUTIONS
Outline Drawing
NOTES:
1. LEADFRAME MATERIAL: COPPER ALLOY
2. DIMENSIONS ARE IN INCHES [MILLIMETERS].
3. LEAD SPACING TOLERANCE IS NON-CUMULATIVE
4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM.
PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM.
5. PACKAGE WARP SHALL NOT EXCEED 0.05mm.
6. ALL GROUND LEADS AND GROUND PADDLE MUST
BE SOLDERED TO PCB RF GROUND.
7. REFER TO HITTITE APPLICATION NOTE FOR SUGGESTED
PCB LAND PATTERN.
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, T = +25C
A
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 6
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Package Information
Part Number
Package Body Material
Lead Finish
MSL Rating
MSL1 [1]
Package Marking [3]
H600
XXXX
HMC600LP4
Low Stress Injection Molded Plastic
Sn/Pb Solder
H600
XXXX
MSL1 [2]
HMC600LP4E
RoHS-compliant Low Stress Injection Molded Plastic
100% matte Sn
[1] Max peak reflow temperature of 235 °C
[2] Max peak reflow temperature of 260 °C
[3] 4-Digit lot number XXXX
Pin Descriptions
12
Pin Number
Function
Description
Interface Schematic
These pins are not connected internally; however,
this product is specified with these pins connected
to RF/DC ground.
1, 6, 7-13,
15, 18-24
N/C
2, 6
Vcc1, Vcc2
Bias supply. Connect supply voltage to both pins.
RF Input pins. Connect RF to INP, and AC couple
INN to ground for single-ended operation.
3, 4
INP, INN
Connect to 0V for normal operation. Applying voltage
>0.8 x Vcc will initiate a power saving shutdown mode.
14
PWD
To ensure proper start-up apply the power-up sequence
shown in the “Power-Up Timing Diagram” attached to the
application circuit.
VSET input in controller mode. Short this
pin to LOGOUT for detector mode.
16
17
VSET
Logarithmic output that converts the input power
to a DC level in detector mode. Short this pin to
VSET for detector mode.
LOGOUT
Package
Base
GND
Exposed paddle must be connected to RF and DC ground.
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 7
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Evaluation PCB
12
List of Materials for Evaluation PCB 115242 [1]
The circuit board used in the final application should
use RF circuit design techniques. Signal lines
should have 50 ohm impedance while the package
ground leads and exposed paddle should be con-
nected directly to the ground plane similar to that
shown. A sufficient number of via holes should be
used to connect the top and bottom ground planes.
The evaluation circuit board shown is available from
Hittite upon request.
Item
Description
J1 - J4
J5 - J8
C1, C2
C3, C4
R1, R2
R3-R5
PC Mount SMA Connector
DC Pin
1000 pF Capacitor, 0402 Pkg.
0.1μF Capacitor, 0402 Pkg.
5.6Ω Resistor, 0603 Pkg.
0Ω Resistor, 0603 Pkg.
HMC600LP4 / HMC600LP4E
Logarithmic Detector / Controller
U1
[2]
PCB
115244 Evaluation PCB
[1] Reference this number when ordering complete evaluation PCB
[2] Circuit Board Material: Rogers 4350
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
rights of third parties that may result from its use. Specifications subject to change without notice. No
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 8
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Application & Evaluation PCB Schematic
12
Notes
Note 1: The HMC600LP4 & HMC600LP4E evaluation boards are pre-assembled for single-ended input, and detector/RSSI mode.
Note 2: For single-ended input operation, use the INP port and make no connection to INN. INN is AC coupled to ground by C2
Note 3: For differential input, remove C2, and install a 1000pF capacitor in series with INN at location shown.
Note 4: For detector mode, connect high impedence volt meter to the LOGOUT port, and make no connection to VSET. LOGOUT
is shorted to VSET by R3, as required for detector mode.
Note 5: For controller mode, remove R3 and make appropriate connection to LOGOUT and VSET. In controller mode, the
LOGOUT output can be used to drive a variable gain amplifier, or a variable attenuator, either directly or through a buffer
or microcontroller. VSET should be connected to an external supply, typically between +0.6 and +1.9V.
Power-Up Timing Diagram
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
For price, delivery, and to place orders: Analog Devices, Inc.,
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106
Phone: 781-329-4700 • Order online at www.analog.com
Application Support: Phone: 1-800-ANALOG-D
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
12 - 9
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明