AME3-5SBJZ [AIMTEC]
AC-DC / DC-DC Converter;Click on Series name for product info on aimtec.com
Series AME3-BJZ
3 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 3000VAC
• Class II Power supply
• Low no load consumption ≤ 0.5W
• Continuous Short Circuit Protection
• Operating Temp: -40°C to +70°C
• Input 90-528VAC, 47-63Hz, or 100-745 VDC
• Over current Protection
Models
Single output
Maximum
capacitive
Load
(µF)
Efficiency
(%)
Input
Voltage
(VDC)
Temperature
range
Output
Voltage
(V)
Output
Current max
(mA)
Input Voltage
(VAC/Hz)
Model
230
(ºC)
VAC
AME3-3.3SBJZ
AME3-5SBJZ
AME3-9SBJZ
AME3-12SBJZ
AME3-15SBJZ
AME3-24SBJZ
90-528/47-63
90-528/47-63
90-528/47-63
90-528/47-63
90-528/47-63
90-528/47-63
100-745
100-745
100-745
100-745
100-745
100-745
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
3.3
5
9
12
15
24
500
500
333
250
200
125
2200
1100
680
680
560
470
63
70
73
76
76
76
Input Specifications
Parameters
Conditions
Typical
Maximum
Units
115 VAC
230 VAC
480 VAC
115 VAC
230 VAC
480 VAC
120
60
40
Current (full load)
mA
9
15
27
0.25
2
Inrush current <2ms (cold start)
A
Leakage current
External fuse
230VAC/50Hz, rms
Recommended slow blow type
mA
A
Output Specifications
Parameters
Conditions
3.3V output
Typical
±6
Maximum
Units
Voltage accuracy
%
Others
±5
LL-HL, Full Load, 3.3V output
LL-HL, Full Load, Others
10% - 100% load, nominal input
20MHz bandwidth, 115/230VAC, Full Load
230VAC
±2.5
±1.5
±2.5
Line regulation
%
Load regulation
Ripple & Noise*
Hold up time
%
mV p-p
ms
180
40
*With output filter capacitors referenced in the application circuit.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
Typical
Rated
3000
Units
VAC
MΩ
60 sec
>1000
General Specifications
Parameters
Switching frequency
Conditions
Typical
Maximum
Units
KHz
65
Over Current protection
Auto recovery
230VAC
150-300
% of Iout
0.3
0.5
No load consumption
W
528VAC
Short circuit protection
Operating temperature
Storage temperature
Temperature coefficient
Maximum Case temperature
Humidity
Auto recovery, Continuous
-40 to +70
See derating curve
°C
°C
%/°C
°C
-40 to +105
±0.15
95
85
Non-condensing
% RH
www.aimtec.com
F 052e R1
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME3-BJZ
3 Watt | AC-DC / DC-DC Converter
Case material
Weight
Plastic resin (flammability to UL 94V-0)
30
g
Cooling
Free air convection
Dimensions (L x W x H)
2.0 x 1.0 x 0.6 inches 50.80 x 25.40 x 15.16mm
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25°C) at Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Safety Specifications
Parameters
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Meets IEC/EN/UL 60950-1
EN55022, class A; class B with the recommended EMC circuit
IEC 61000-4-2, Contact: ±6KV/Air: ±8KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A with the recommended EMC circuit
IEC 61000-4-4, ±2KV; ±4KV with the recommended EMC circuit, Criteria B
IEC 61000-4-5, ±1KV; ±2KV with the recommended EMC circuit, Criteria B
IEC 61000-4-6, 3Vrms, Criteria A with the recommended EMC circuit
IEC 61000-4-11, 0-70%, Criteria B with the recommended EMC circuit
Standards
RF, Conducted Disturbance Immunity
Voltage dips, Short Interruptions Immunity
Dimensions
50.80
(2.00)
Case Temperature
Measurement point
45.72
(1.80)
1
3
4
1
2
3
TOP VIEW
+
10.16
(0.40)
25.40
(1.00)
20.32
(0.80)
TOP VIEW
4
5
2
15.16
(0.60)
DIV: 5.08 (0.2)
Ø 1.5 (Ø 0.06)
Ø 1.00
(0.04)
Dimensions: inch (mm)
Case Tolerance:± 0.50 (0.02)
Pin Pitch Tolerance: ± 0.10 (0.004)
Pin Out Specifications
Pin
1*
2*
3
Single
AC Input (N) or (L1)
AC Input (L) or (L2)
+V Output
* Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line
voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
4
-V Output
www.aimtec.com
F 052e R1
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME3-BJZ
3 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection
Free Air Convection
100
100
80
Safe Operating Area
80
70
60
Safe Operating Area
100% load 90-165VAC
Or 100-230VDC
165-528VAC
230-745VDC
70
60
40
40
20
0
20
0
55
55
60
70
70
80
100
80
100
- 40 -20
0
20
40
60
- 40 -20
0
20
40
º C
º C
Ambient Temperature
Ambient Temperature
Free Air Convection at 25°C
100
80
Safe Operating Area
60
40
20
0
90
110
480
528
(100) (155)
(675)
(745)
Input Voltage VAC (VDC)
Application circuit
Single Output
FUSE
2A
4
3
+ Vout
- Vout
AC L
AC L
TVS
+
C2
MOV
S14K550
AC
DC
C1
100nF/50V
AC N
AC N
*GND connection not allowed
www.aimtec.com
F 052e R1
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME3-BJZ
3 Watt | AC-DC / DC-DC Converter
Class B compliance recommended circuit
Single Output
FUSE
2A
MOV 2
S07K300
R1
12 /2W
+Vout
+Vout
AC L
AC L
CY1
470pF/
500VAC
MOV 1
S14K550
TVS
CX
220nF/
530VAC
C2
+
LCM
10mH
AC
DC
C1
100nF/
50V
CY2
R2
12 /2W
470pF/
500VAC
- Vout
- Vout
AC N
AC N
GND
MOV 3
S07K300
Model
3.3 Vout
5 Vout
9 Vout
12 & 15 Vout
24 Vout
C2
TVS
7V
7V
12V
20V
30V
100 µF / 16V
47 µF / 16V
47 µF / 35V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R1
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only