AMEL5-AZ_16 [AIMTEC]
5 Watt | AC-DC / DC-DC Converter;![AMEL5-AZ_16](http://pdffile.icpdf.com/pdf2/p00339/img/icpdf/AMEL5-AZ-1-1_2085626_icpdf.jpg)
型号: | AMEL5-AZ_16 |
厂家: | ![]() |
描述: | 5 Watt | AC-DC / DC-DC Converter |
文件: | 总5页 (文件大小:561K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Click on Series name for product info on aimtec.com
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:
I/O Isolation 3000VAC
RoHS compliant
Energy Star compliant
Efficiency up to 76%
Operating Temp: -40 oC to +95 oC
Input: 90-305VAC, 47-440Hz, or 130-430VDC
Over load, Over Voltage, Short Circuit Protection
Soft start
Models
Single output
Efficiency
(%)
Maximum
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
Output
Voltage
(V)
Output
Current
max (A)
capacitive
Load
(µF)
Model
115
VAC
230
VAC
277
VAC
(ºC)
AMEL5-3.3SAZ
AMEL5-5SAZ
AMEL5-12SAZ
AMEL5-15SAZ
AMEL5-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +95
-40 to +95
-40 to +95
-40 to +95
-40 to +95
3.3
5
12
15
24
1. 5
1
0.42
0.333
0.21
2200
1100
680
330
220
71
72
75
75
75
71
73
76
75
76
69
72
76
73
75
Note: 1. Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SAZ-ST);
2. Optional version with incorporated filter for Earth to Ground connection can be ordered by adding “G” to the model suffix (ex.
AMEL5-5SGAZ).
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Typical
Maximum
120
Units
mA
mA
mA
A
80
70
15
30
Current (full load)
A
A
Inrush current <2ms (cold start)
40
Leakage current
External fuse
Input dissipation
0.2
mA
A
W
Recommended slow blow type
(110/230/277 VAC)
1.5
≦0.2
150
Start-up time
115 VAC/ Full Load
ms
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
Maximum
Units
%
±2
Line regulation
±1
%
Load regulation
0-100% load
±1
%
Transient recovery time
Transient response deviation
200
±2
75
100
150
5
µs
25% load step
3.3/5V models
12/15V models
24V models
% of Vout
mV p-p
mV p-p
mV p-p
ms
Ripple & Noise*
Hold-up time
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Conditions
Typical
Rated
3000
Units
VAC
MΩ
Tested I/O voltage
Isolation Resistance
60 sec
>1000
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum case temperature
Temperature coefficient
Cooling
Conditions
Typical
66
130
Maximum
Units
KHz
%
Foldback
Zener Diode Clamp
Auto recovery
With derating over 60ºC, see chart
Refer to model application
oC
oC
-40 to +95
100
oC
0.02
% / oC
Free air convection
Humidity
Case material
Weight
Non condensing
20 ~ 95
% RH
g
Plastic (flammability to UL 94V-0)
30
Dimensions (L x W x H)
51.50 x 28.00 x 17.80mm (2.03 x 1.10 x 0.70inches)
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Parameters
Conditions
Wave form
Acceleration amplitude
Bump duration
Half sine wave
5gn
30ms
Shock
Converter operation
Number of bumps
Test mode
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1mm
Displacement
Vibrations
Acceleration
Converter operation
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus for all models CE, CB (not including suffix “GAZ” models)
Information technology Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
IEC\EN\UL 60950-1
EN 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Air level 3, Contact level 2
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 2
IEC 61000-4-6 Level 2
IEC 61000-4-8
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC 61000-4-11
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
Additional Surge Protective Circuitry
The AMEL5-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater
protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide
Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.
Vrms
V
Vdc
V
Wmax (2ms)
Pmax
W
MOV PN
J
S14K320E2
320
420
136
0.6
Pin Out Specifications
Pin
1
2
3
4
5
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
Dimensions
2.03
(51.50)
1.80
(45.72)
1
2
3
4
5
1
2
3
4
5
0.40
(10.16)
1.10
(28.00)
0.80
(20.32)
TOP VIEW
TOP VIEW
0.40
(10.16)
0.11
(2.89)
17.80
(0.70)
5 Ø- 0.047 (Ø 1.2)
DIV: 0.2 (5.08)
Ø 0.04
(1.00)
Dimensions: inch (mm)
Case Tolerance:± 0.012 (0.30)
Pin Pitch Tolerance: ± 0.012 (0.30)
0.2
(5.08)
(Min)
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
Derating
Earth/Ground Connection for AMEL5-xxSGAZ models
L
+Vout
-Vout
100-277VAC
AMEL5‐xxSGAZ
N
AMEL5‐xxSGAZ models meet the EN55022 class B compliance when connected to Earth/Ground. These models are
incorporating an EMC compliant filter and when connected to Earth/GND, no external filtering will be needed to meet the
specified limits.
Models include: AMEL5‐3.3SGAZ, AMEL5‐5SGAZ, AMEL5‐12SGAZ, AMEL5‐15SGAZ, and AMEL5‐24SGAZ
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
Dimensions of Optional ST Mounting Plate Version
Pin Out Specification ST Version
86.00
70.00
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号: