AMEL5-AZ_16 [AIMTEC]

5 Watt | AC-DC / DC-DC Converter;
AMEL5-AZ_16
型号: AMEL5-AZ_16
厂家: AIMTEC    AIMTEC
描述:

5 Watt | AC-DC / DC-DC Converter

文件: 总5页 (文件大小:561K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Click on Series name for product info on aimtec.com  
Series AMEL5-AZ  
5 Watt | AC-DC / DC-DC Converter  
FEATURES:  
I/O Isolation 3000VAC  
RoHS compliant  
Energy Star compliant  
Efficiency up to 76%  
Operating Temp: -40 oC to +95 oC  
Input: 90-305VAC, 47-440Hz, or 130-430VDC  
Over load, Over Voltage, Short Circuit Protection  
Soft start  
Models  
Single output  
Efficiency  
(%)  
Maximum  
Input  
Voltage  
(VAC/Hz)  
Input  
Voltage  
(VDC)  
Temperature  
range  
Output  
Voltage  
(V)  
Output  
Current  
max (A)  
capacitive  
Load  
(µF)  
Model  
115  
VAC  
230  
VAC  
277  
VAC  
(ºC)  
AMEL5-3.3SAZ  
AMEL5-5SAZ  
AMEL5-12SAZ  
AMEL5-15SAZ  
AMEL5-24SAZ  
90-305/47-440  
90-305/47-440  
90-305/47-440  
90-305/47-440  
90-305/47-440  
130-430  
130-430  
130-430  
130-430  
130-430  
-40 to +95  
-40 to +95  
-40 to +95  
-40 to +95  
-40 to +95  
3.3  
5
12  
15  
24  
1. 5  
1
0.42  
0.333  
0.21  
2200  
1100  
680  
330  
220  
71  
72  
75  
75  
75  
71  
73  
76  
75  
76  
69  
72  
76  
73  
75  
Note: 1. Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SAZ-ST);  
2. Optional version with incorporated filter for Earth to Ground connection can be ordered by adding “G” to the model suffix (ex.  
AMEL5-5SGAZ).  
Input Specifications  
Parameters  
Conditions  
115 VAC  
230 VAC  
277 VAC  
115 VAC  
230 VAC  
277 VAC  
Typical  
Maximum  
120  
Units  
mA  
mA  
mA  
A
80  
70  
15  
30  
Current (full load)  
A
A
Inrush current <2ms (cold start)  
40  
Leakage current  
External fuse  
Input dissipation  
0.2  
mA  
A
W
Recommended slow blow type  
(110/230/277 VAC)  
1.5  
0.2  
150  
Start-up time  
115 VAC/ Full Load  
ms  
Output Specifications  
Parameters  
Voltage accuracy  
Conditions  
Typical  
Maximum  
Units  
%
±2  
Line regulation  
±1  
%
Load regulation  
0-100% load  
±1  
%
Transient recovery time  
Transient response deviation  
200  
±2  
75  
100  
150  
5
µs  
25% load step  
3.3/5V models  
12/15V models  
24V models  
% of Vout  
mV p-p  
mV p-p  
mV p-p  
ms  
Ripple & Noise*  
Hold-up time  
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.  
Isolation Specifications  
Parameters  
Conditions  
Typical  
Rated  
3000  
Units  
VAC  
M  
Tested I/O voltage  
Isolation Resistance  
60 sec  
>1000  
www.aimtec.com  
F 052e R8.O  
Tel: +1 514 620 2722  
1 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEL5-AZ  
5 Watt | AC-DC / DC-DC Converter  
General Specifications  
Parameters  
Switching frequency  
Over load protection  
Over voltage protection  
Short circuit protection  
Operating temperature  
Storage temperature  
Maximum case temperature  
Temperature coefficient  
Cooling  
Conditions  
Typical  
66  
130  
Maximum  
Units  
KHz  
%
Foldback  
Zener Diode Clamp  
Auto recovery  
With derating over 60ºC, see chart  
Refer to model application  
oC  
oC  
-40 to +95  
100  
oC  
0.02  
% / oC  
Free air convection  
Humidity  
Case material  
Weight  
Non condensing  
20 ~ 95  
% RH  
g
Plastic (flammability to UL 94V-0)  
30  
Dimensions (L x W x H)  
51.50 x 28.00 x 17.80mm (2.03 x 1.10 x 0.70inches)  
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load  
MTBF  
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load  
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at  
rated output load unless otherwise specified.  
Environment Approval  
Test  
Parameters  
Conditions  
Wave form  
Acceleration amplitude  
Bump duration  
Half sine wave  
5gn  
30ms  
Shock  
Converter operation  
Number of bumps  
Test mode  
Before and after test, body mounted (on chassis)  
18 (3 in each direction for every axis)  
Sweep sine, 10-100Hz, speed 0.05Hz/s  
1mm  
Displacement  
Vibrations  
Acceleration  
Converter operation  
3g, 3 loops 30min one cycle, 3h total, every axis tested  
Before and after test, body mounted (on chassis)  
Safety Specifications  
Parameters  
Agency approvals  
cULus for all models CE, CB (not including suffix “GAZ” models)  
Information technology Equipment  
Information technology Equipment  
EMI - Conducted and radiated emission  
Harmonic Current Emissions  
IEC\EN\UL 60950-1  
EN 60950-1:2006+A11:2009  
EN55022, class B  
IEC/EN 61000-3-2, Class A  
IEC/EN 61000-3-3, (EN60555-3)  
IEC 61000-4-2 Air level 3, Contact level 2  
IEC 61000-4-3 Level 2  
IEC 61000-4-4 Level 2  
IEC 61000-4-5 Level 2  
IEC 61000-4-6 Level 2  
IEC 61000-4-8  
Voltage fluctuations and flicker  
Electrostatic Discharge Immunity  
RF, Electromagnetic Field Immunity  
Electrical Fast Transient/Burst Immunity  
Surge Immunity  
RF, Conducted Disturbance Immunity  
Power frequency Magnetic Field Immunity  
Voltage dips, Short Interruptions Immunity  
Standards  
IEC 61000-4-11  
www.aimtec.com  
F 052e R8.O  
Tel: +1 514 620 2722  
2 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEL5-AZ  
5 Watt | AC-DC / DC-DC Converter  
Additional Surge Protective Circuitry  
The AMEL5-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater  
protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide  
Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.  
Vrms  
V
Vdc  
V
Wmax (2ms)  
Pmax  
W
MOV PN  
J
S14K320E2  
320  
420  
136  
0.6  
Pin Out Specifications  
Pin  
1
2
3
4
5
Single  
AC Input (N)  
AC Input (L)  
+V Output  
-V Output  
No pin  
Dimensions  
2.03  
(51.50)  
1.80  
(45.72)  
1
2
3
4
5
1
2
3
4
5
0.40  
(10.16)  
1.10  
(28.00)  
0.80  
(20.32)  
TOP VIEW  
TOP VIEW  
0.40  
(10.16)  
0.11  
(2.89)  
17.80  
(0.70)  
5 Ø- 0.047 (Ø 1.2)  
DIV: 0.2 (5.08)  
Ø 0.04  
(1.00)  
Dimensions: inch (mm)  
Case Tolerance:± 0.012 (0.30)  
Pin Pitch Tolerance: ± 0.012 (0.30)  
0.2  
(5.08)  
(Min)  
www.aimtec.com  
F 052e R8.O  
Tel: +1 514 620 2722  
3 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEL5-AZ  
5 Watt | AC-DC / DC-DC Converter  
Derating  
Earth/Ground Connection for AMEL5-xxSGAZ models  
L
+Vout  
-Vout  
100-277VAC  
AMEL5xxSGAZ  
N
AMEL5xxSGAZ models meet the EN55022 class B compliance when connected to Earth/Ground. These models are  
incorporating an EMC compliant filter and when connected to Earth/GND, no external filtering will be needed to meet the  
specified limits.  
Models include: AMEL53.3SGAZ, AMEL55SGAZ, AMEL512SGAZ, AMEL515SGAZ, and AMEL524SGAZ  
www.aimtec.com  
F 052e R8.O  
Tel: +1 514 620 2722  
4 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEL5-AZ  
5 Watt | AC-DC / DC-DC Converter  
Dimensions of Optional ST Mounting Plate Version  
Pin Out Specification ST Version  
86.00  
70.00  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.  
www.aimtec.com  
F 052e R8.O  
Tel: +1 514 620 2722  
5 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  

相关型号:

AMEL5-CJZ

Over current, Over Voltage Protection
AIMTEC

AMEL5-JZ

Over current, Over Voltage Protection
AIMTEC

AMEL5-MAZ

5 Watt | AC-DC Converter
AIMTEC

AMEL5-MAZ-1_16

5 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL5-MAZ_12

5 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL5-MAZ_13

5 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL5-MAZ_16

5 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL5-VZ

AC-DC Converter
AIMTEC

AMEL60-12SJZ

AC-DC Regulated Power Supply Module
AIMTEC

AMEL60-15SJZ

AC-DC Regulated Power Supply Module
AIMTEC

AMEM5-12SY

AC-DC Converter
AIMTEC

AMEM5-15SY

AC-DC Converter
AIMTEC