AMEPR30D-15200AZ-110 [AIMTEC]
up to 2A | AC-DC LED driver;型号: | AMEPR30D-15200AZ-110 |
厂家: | AIMTEC |
描述: | up to 2A | AC-DC LED driver |
文件: | 总5页 (文件大小:505K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
ATURES:
AC-DC Constant current LED Driver
Input range 90-264VAC/47-440Hz
Active PFC with TRIAC dimmable
Operating temperature -20 to 80°C
Total Harmonic Distortion < 20%
5 Year Limited Warranty
Leading or Trailing Edge Triac
IP67 Case
High Efficiency up to 87%
SCP, Over Load Protection
②
Single output
No Load
Output
Voltage
(V max.)
Max
Output
Voltage
Range
(V)
36-50
32-42
24-36
24-36
12-24
12-24
8-15
Efficiency
Output
Power
Output
Current (A)
Input Voltage
(VAC/Hz)
(%)
Model
115
230
①
VAC
VAC
(W)
②
AMEPR30D-5070AZ +Suffix
AMEPR30D-4270AZ+Suffix
AMEPR30D-3670AZ+Suffix
AMEPR30D-36100AZ+Suffix
AMEPR30D-24125AZ+Suffix
AMEPR30D-24140AZ+Suffix
AMEPR30D-15200AZ+Suffix
35
29.4
25.2
36
64
54
52
52
34
34
23
0.7
0.7
0.7
1
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
82
84
83
83
82
80
78
85
87
84
84
84
83
80
②
②
②
②
②
②
30
1.25
1.4
2
33.6
30
①
Exceeding the maximum output power will permanently damage the converter.
②
Model Nomenclature for Ordering:
Add Suffix “-U”
Add Suffix “-110”
Add Suffix “-220”
Universal AC input 90-264VAC, (no TRIAC dimming option)
AC input 90-135VAC, 115VAC typical value
AC input 180-264VAC, 230VAC typical value
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR30D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone
to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause
early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Leakage current
Conditions
115VAC
230VAC
Typical
15
30
0.25
500
350
Maximum
Units
A
mA
mA
115VAC
230VAC
AC current
115VAC
230VAC
Recommended slow blow
type
0.9
0.9
1
Power Factor
External fuse
A
Start up time
200
ms
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
±7
±10
±7
LL-HL
0-100% load
Load regulation
%
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
③
3
1
V p-p
ms
Ripple & Noise
Hold-up time
Minimum Load Voltage
See the models table
③ꢀRipple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Conditions
Typical
Maximum
Units
VAC
MΩ
Tested I/O voltage
Isolation Resistance
60sec
3000
>1000
General Specifications
Parameters
Switching frequency
Over load protection
Conditions
Typical
Maximum
Units
KHz
%
65
≧
110
Over voltage protection
%
≧
110
Short circuit protection
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Wires
Weight
Auto recovery
>105°C
With derating over 55°C
-20 to +80
oC
oC
100
95
-40 to +95
±0.02
Free air convection
oC
% / oC
% RH
g
Plastic
UL1015 Input 18AWG*10CM/ Output 20 AWG * 10CM
200
Dimensions (L X H X W)
MTBF
133x33x30mm (5.24 x 1.30 x 1.18 inch)
>400,000 hrs (MIL-HDBK-217F at +25°C)
Environment Approval
Test
Parameters
Conditions
Wave form
Half sine wave
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
5gn
30 ms
Shock
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Vibration
Safety Specifications
Parameters
Agency approvals
cULus, CE, FCC
EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024, FCC Part 15 Subpart B, Class
B, ANSI C63.4 :2003
Harmonic Current Emissions
Voltage fluctuations and flicker
IEC/EN 61000-3-2, Class C
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 2
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 2
IEC 61000-4-11
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
Dimensions
Temperature Graph
Free Air Convection
º C
55
100
80
60
40
20
0
Safe Operating Area
- 25 - 20
0
20
40
60
80
º C
100
Ambient Temperature
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
Triac Dimming Feature
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
Triac Dimming Performance
AMEPR30D-3670AZ
Triac dimming performance is typical as with other models, for specific details on other model
performance, please see the Aimtec Triac Dimming Application note at www.aimtec.com
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明