AMER120-36340CAZ [AIMTEC]
up to 5A | AC-DC / DC-DC | LED Driver / Converter; 高达5A | AC -DC / DC - DC | LED驱动器/转换器型号: | AMER120-36340CAZ |
厂家: | AIMTEC |
描述: | up to 5A | AC-DC / DC-DC | LED Driver / Converter |
文件: | 总10页 (文件大小:689K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Constant Current or Constant Voltage LED
Driver or Converter
Input range 90-305VAC/47-440Hz
High Efficiency up to 91%
Over Temperature Protection
Over Current Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
115VAC Operating temperature -50 to 85°C
230VAC Operating temperature -55 to 85°C
Models
②
Dimming via analog / 0-10V dimming
Single output
Max
Output
Voltage
Range (V)
36-50
Output
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Output
Power
(W)
Mode of
Operation
Efficiency
(%)
Current
Model
③
③
(A)
①
Constant Current
91
90
90
89
89
87
AMER120-50250CAZ
AMER120-36340CAZ
AMER120-24500CAZ
125
122.4
120
0-2.5
0-3.4
0-5
90-305/47-440
90-305/47-440
90-305/47-440
120-430
120-430
120-430
②
②
②
Constant Voltage
Constant Current
24-36
Constant Voltage
Constant Current
12-24
Constant Voltage
Add Suffix “-F”
No dimming option
①
Exceeding the maximum output power will permanently damage the converter
The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
②
option in this case.
③
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
240VAC
Typical
45
Maximum
Units
Inrush current <2ms
A
60
0.5
0.75
1.8
0.7
Leakage current
AC current
mA
A
0.98
0.94
Power Factor
External fuse
Start up time
Surge voltage
250V/3A
900
ms
V
2sec
440
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
±3
±1
LL-HL
Load regulation
0-100% load
20MHz Bandwidth
±3
100
%
mV p-p
④
Ripple & Noise
Hold-up time
Current adjustment range
80
100-0
ms
%
Minimum Load Voltage
See the models table
④
Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
1 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Isolation Specifications
Parameters
Tested I/P-O/P voltage
Tested I/P-FG voltage
Tested O/P-FG voltage
Isolation Resistance
Conditions
3sec
3sec
3sec
500VDC
Typical
Rated
3750
1880
500
Units
VAC
VAC
VAC
MΩ
>1000
Isolation Capacitance
1000
pF
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
(See Derating Table)
Cold Start-up Time
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Conditions
Typical
100
110% of Iout
110% of Vout
Maximum
Units
KHz
Continuous
Auto recovery
>105°C
(115VAC)
(230VAC)
-55°C
-50 to +85
-55 to +85
oC
oC
30
100
Sec
oC
-55 to +95
±0.02
Free air convection
oC
% / oC
Humidity
Case material
Potting
Wires
95
% RH
g
Aluminum
Epoxy (IP68 rated)
UL1015 18AWG Input & 14AWG Output *20CM
750
Weight
Dimensions (L X H X W)
MTBF
7.13 x 2.32 x 1.85 inches
181.00 x 59.00 x 47.00 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
Safety Specifications
Parameters
Agency approvals
CE
EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
NOTE : also designed to meet cULus, UL8750, UL60950-1
Standards
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
2 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
Analog (resistive) Dimming Application Circuit
Maximum Pot
Model Number
Value (kΩ)
AMER120-50250CAZ
AMER120-36340CAZ
AMER120-24500CAZ
18.22
22.10
34.31
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
3 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
0-10V Dimming Application Circuit
Derating
Free Air Convection
230 VAC
CV mode
CC Mode
50°C 50°C
100
80
60
Safe Operating Area
40
20
0
85°C
80°C
80
º C
100
- 55 - 30
0
20
40
60
Ambient Temperature
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
4 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Efficiency vs. Input Voltage and Output Current (CC Load)
AMER120-50250CAZ
AMER120-36340CAZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
5 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Efficiency vs. Input Voltage and Output Current (CC Load)
Continued
AMER120-24500CAZ
PFC Value vs. Output Load Current (CC Load)
AMER120-50250CAZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
6 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
PFC Value vs. Output Load Current (CC Load)
AMER120-36340CAZ
AMER120-24500CAZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
7 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Constant Current Mode vs. Constant Voltage Mode
AMER120-50250CAZ
AMER120-36340CAZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
8 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Constant Current Mode vs. Constant Voltage Mode
AMER120-24500CAZ
Output Current vs. Radj
AMER120-50250CAZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
9 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Output Current vs. Radj
AMER120-36340CAZ
AMER120-24500CAZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
10 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明