Series AMER60-Z
up to 1600mA | AC-DC LED driver
FEATURES:
• Universal Input: 90~305 Vac
• High Efficiency: Up to 90%
• Active Power Factor Correction
•
•
•
•
IP65/67 Design for outdoor application
Long Life, High reliability
Meet UL, CE Safety Requirement
5-year limited warranty
• Short Circuit / Open Circuit Protection
Models
Single output
Max Output
Output Voltage
Range
(V)
Output Current
(A)
Input Voltage
(VAC/Hz)
Efficiency
(%)
Model
Power
(W)
AMER60-42130Z
AMER60-42140Z
AMER60-42150Z
AMER60-42160Z
54.6
58.8
63.0
67.2
24-42
24-42
24-42
24-42
1.3
1.4
1.5
1.6
90-305/47-63
90-305/47-63
90-305/47-63
90-305/47-63
89
89
90
90
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Conditions
Typical
Maximum
1.0
Units
Arms
90 VAC, full load
115 VAC, cold start
277 VAC, cold start
40
60
Inrush current <2ms
A
Leakage current
Input dissipation
0.75
1.0
mA
W
No Load
Output Short
4.5
W
115 VAC, full load
277 VAC, full load
0.98
0.92
Power Factor
Input Fuse
2A / 300VAC
115 VAC, full load
277 VAC, full load
1.5
1.0
Sec.
Sec.
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise
Conditions
Typical
Maximum
Units
%
%
%
V p-p
A p-p
±5
±3
±5
LL to HL
Full Output Voltage Range
Full load
Full load, 16.7-20ms duration
LL to HL, full load at cold start,
% of rated output current
3
1.8
Output Current Ripple
Current Overshoot
10
0
%
Hold-up time (min)
ms
Minimum Load Voltage
See Models Table Above
Isolation Specifications
Parameters
Conditions
I/P – O/P
I/P – FG
Typical
Rated
3750
2000
500
Units
Tested I/O voltage
VAC
O/P – FG
Isolation Resistance
Isolation Capacitance
I/P – O/P, 500Vdc
VAC
pF
>100MΩ
2500
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60-Z
up to 1600mA | AC-DC LED driver
General Specifications
Parameters
Switching frequency
Over voltage protection
Over current protection
Short circuit protection
Short circuit restart
Open circuit protection
Operating temperature
Storage temperature
Maximum case temperature
Temperature coefficient
Cooling
Conditions
Typical
150
Maximum
Units
KHz
VDC
50
Constant Current Mode
Hiccup Mode
Auto Recovery
Hiccup Mode
With Derating over oC
-40 to +60
-40 to +90
oC
oC
90
0.03
oC
% / oC
Free Air Convection
Humidity
Case material
Potting material
IP Rating
90
% RH
g
Metal (Aluminum)
polysiloxane
IP67
460
Weight
Dimensions (L X W+ X H)
MTBF
6.89 X 1.91 X 1.31 inches 175.0 X 48.6 X 33.3 mm
400000 hrs (MIL-HDBK-217F at +25°C)
Safety Specifications
Parameters
Electromagnetic Interference
Harmonic Current Emissions
Voltage fluctuations and flicker
EN55015 / FCC Part 15, Class B
EN61000-3-2, Class B
EN61000-3-3
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A
EN61000-4-3, Test-RS Level 3, Criteria A
EN61000-4-4, Burst EFT Level 3, Criteria A
EN61000-4-5, Line to Neutral 4kV, Line/Neutral to FG 6kV
EN61000-4-6. Test-CS Level 3, Criteria A
EN61000-4-8, Test 3A/m, Criteria A
Standards
EN61000-4-11, Criteria B
Electromagnetic Immunity Requirements Applies EN61547
to Lighting Equipment
Pin Definition
Application Block diagram
Wire
Brown
Connection
AC L
AC_L
FG
Blue
Yellow/Green
Red
AC N
FG
+V Output
-V OUtput
LED+
LED-
AC
Black
AC_N
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60-Z
up to 1600mA | AC-DC LED driver
Dimensions
Efficiency Vs. Input Voltage & Output Voltage
AMER60-42130Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
65.00%
115VAC
230VAC
277VAC
24
27
30
33
36
39
42
Output Voltage(V)
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60-Z
up to 1600mA | AC-DC LED driver
AMER60-42140Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
115VAC
230VAC
277VAC
65.00%
24
27
27
27
30
33
36
39
39
39
42
42
42
Output Voltage(V)
AMER60-42150Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
115VAC
230VAC
277VAC
65.00%
24
30
33
36
Output Voltage(V)
AMER60-42160Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
115VAC
230VAC
277VAC
65.00%
24
30
33
36
Output Voltage(V)
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60-Z
up to 1600mA | AC-DC LED driver
PF Vs. Input Voltage &Output Voltage
AMER60-42130Z
1.200
0.900
0.600
0.300
0.000
115VAC
230VAC
277VAC
24
27
30
33
36
39
42
Output Voltage(V)
AMER60-42140Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
AMER60-42150Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60-Z
up to 1600mA | AC-DC LED driver
AMER60-42160Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号: