Interlock Switches  
Guard Locking Switches  
Spartan  
Specifications  
Standards  
EN954-1, ISO13849-1, IEC/EN60204-1,  
NFPA79, EN1088, ISO14119, IEC/  
EN60947-5-1, ANSI B11.19, AS4024.1  
Category  
Approvals  
Cat. 1 Device per EN954-1  
Dual channel interlocks suitable for  
Cat. 3 or 4 systems  
CE marked for all applicable directives,  
cULus and TUV Nord  
Safety Contact  
Utilization Cat.  
2 N.C. or 3 N.C. direct opening action  
AC 15  
AC (Ue) 500V 250V 100V  
(le) 1A 2A 5A  
DC 250V/0.5A 24V/2A  
Maximum Switched Current/ 500V/500VA  
Volt/Load  
Description  
Thermal Current (lth)  
Min Current  
10A  
The Spartan is a positive mode, tongue operated guard locking  
interlock switch that locks a machine guard closed until power is  
isolated and ensures that it remains isolated while the guard is open.  
It is available in two contact configurations: two safety (N.C.)  
contacts and one auxiliary (N.O.) contact or three safety (N.C.)  
contacts. The Spartan head has two entry slots and it can be rotated  
to provide four actuator entry points. A blanking plug is provided to  
seal the unused slot.  
5V 5mA DC  
Safety Contact Gap  
Rtd. Insulation Voltage  
Rtd. Impulse withstand Volt  
Auxiliary Contacts  
Pollution Degree  
Max Actuation Speed  
Max Actuation Frequency  
Case Material  
>2mm  
500V  
2500V  
1 N.O.  
3
The guard may only be opened when a signal is applied to the  
Spartan’s internal solenoid which releases the lock mechanism.  
Therefore the Spartan is ideal for machines which do not stop  
immediately or where premature interruption of the machine could  
cause damage to tooling and components or cause an additional  
hazard.  
160mm/second (6.3 in/sec)  
1 cycle/second  
UL Approved glass filled polyester  
Stainless steel  
IP 67  
Actuator Material  
Protection  
Conduit Entry  
1 x M20 or quick disconnect style  
-20°C to 60°C (-4°F to +140°F)  
2 x M5  
The locking mechanism withstands forces up to of 1200N (270lbs.)  
and an LED provides visual indication of switch status.  
Operating Temperature  
Fixing  
A catch kit with actuator alignment is also supplied to relieve stress  
on the locking solenoid and to protect the unit from actuator  
damage due to poor guard alignment. Manual release points with  
security screws or special key allow the locked Spartan to be released  
in the event of total power failure on a machine.  
Mounting  
Any position  
Mechanical Life  
1,000,000 operations  
1,000,000 operations  
260g (0.57 lb)  
Red  
Electrical Life  
Weight  
Colour  
Features  
Max Holding Force  
Min Operating Radius  
LED Indication  
1200N (270lbs)  
175mm (6.9in)  
Solenoid monitor LED  
Power to release  
Lid mounted status indication  
High locking force—1200N (270lbs.)  
2 N.C. & 1 N.O. or 3 N.C.  
Power Supply  
24V AC/DC, 110V AC, 230V AC  
(solenoid)  
Rotatable head: 4 possible key entry slots  
Solenoid Power  
Typically 7W 100% ED  
Conductive pollution occurs, or dry, non conductive pollution occurs which  
becomes conductive due to condensation.  
Typical Applications  
Note: Lift-off guards require good alignment when using  
tongue actuated interlock switches.  
IMPORTANT: It must not be possible to lift the guard  
without actuating the interlock. An interlock on either side  
may be required.  
3-24  
Interlock Switches  
Guard Locking Switches  
Spartan  
Product Selection  
Contacts  
Catalogue Num ber  
M20 Conduit/  
Solenoid  
Actuator  
Voltage  
Safety  
2 N.C.  
3 N.C.  
2 N.C.  
3 N.C.  
2 N.C.  
3 N.C.  
Aux.  
1 N.O.  
M20 Conduit  
440G-S36001  
440G-S36007  
440G-S36003  
440G-S36009  
440G-S36005  
440G-S36011  
1/2in Adaptor  
440G-S36044  
440G-S36047  
440G-S36045  
440G-S36048  
440G-S36046  
440G-S36049  
Q uick Disconnect  
440G-S36058  
440G-S36059  
440G-S36060  
440G-S36061  
440G-S36062  
440G-S36063  
24 V AC/DC  
1 N.O.  
--  
Standard  
110 V AC/DC  
230V AC/DC  
1 N.O.  
Mating cable 2m (6.5ft). See page 15-13 for details and additional lengths.  
889M-F12X9AE-2  
Accessories  
Description  
For Dim ensions refer to page  
Catalogue Num ber  
440G-A36050  
Replacement Actuator with Catch  
14-4  
14-4  
Retainer and Guide  
Emergency Override  
440G-A36026  
3-25  
Interlock Switches  
Guard Locking Switches  
Spartan  
Approximate Dimensions—mm (inches)  
Dimensions are not intended to be used for installation purposes.  
14.5  
(0.57)  
12 (0.47)  
120 (4.72)  
Conduit Entry (M20)  
40 (1.57)  
8 (0.31)  
9 (0.35)  
Emergency  
Release Points  
7 (0.28)  
5 (0.2)  
5.5 (0.22)  
8
(0.3)  
34.5  
(1.36)  
Key  
Ø5.5  
(0.22)  
Typical Wiring Diagrams  
2 N.C. + 1 N.O.  
3 N.C.  
Auxiliary Circuit  
Safety Circuit 3  
Safety Circuit 2  
Safety Circuit 1  
Safety Circuit 2  
Safety Circuit 1  
22 34  
33 21  
22 32  
31 21  
12  
11  
12  
11  
AC/DC  
Solenoid Power  
AC/DC  
Solenoid Power  
A2  
A1  
A2  
A1  
Solenoid  
Solenoid  
AC/DC  
AC/DC  
100% ED.  
100% ED.  
2 N.C. + 1 N.O.  
3 N.C.  
Connector Pinout  
Term inal  
Contact  
Term inal  
Contact  
1
3
A1  
A2  
11  
12  
21  
22  
33  
34  
A1  
A2  
11  
12  
21  
22  
31  
32  
Solenoid  
Power  
Solenoid  
Power  
4
N.C.  
N.C.  
N.O.  
N.C.  
N.C.  
N.C.  
8
9
1
6
2
12 10  
11  
7
7
6
3
8
5
4
9
10  
12  
Ground  
Contact Action  
2 N.C. + 1 N.O.  
3 N.C.  
Contact Open  
Contact Closed  
12  
11/12  
21/22  
33/34  
6
0mm  
12  
11/12  
21/22  
33/34  
6
0mm  
Actuator withdrawal distance  
from full insertion  
2.5  
2.5  
3-26  
Interlock Switches  
Guard Locking Switches  
Spartan  
Application Details  
4 possible actuator entry positions  
1
2
Locking Force = 1200N  
3-27  

相关型号:

440GJ031M1303-KT

Connector Accessory,
GLENAIR

440GJ031NF1302-BT

Connector Accessory,
GLENAIR

440GP

Power PC 440GP Embedded Processor
AMCC

440GR

Power PC 440GR Embedded Processor
AMCC

440GRX

PowerPC 440GRx Embedded Processor
AMCC

440GS031B2912-4

Connector Accessory,
GLENAIR

440GS031B2912-4B

Connector Accessory,
GLENAIR

440GS031B3314-2

Connector Accessory,
GLENAIR

440GS031M1303-4KT

Connector Accessory,
GLENAIR

440GS031M1332-4KT

Connector Accessory
GLENAIR

440GS031M1337-4T

Connector Accessory
GLENAIR

440GS031NF1304-3

Connector Accessory,
GLENAIR