TR-11CX632.7A [ALTECH]
UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment; UL1077认可辅助保护器/断路器的设备型号: | TR-11CX632.7A |
厂家: | ALTECH CORPORATION |
描述: | UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment |
文件: | 总3页 (文件大小:479K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TR11 Series
E209569
up to 12 Amps
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Applications:
Protection of single phase Motors, Transformers,
UPS, Power strips, Solenoids etc., against
damage due to overcurrent conditions.
Current Rating
Rated Voltage
0.5 -16.0A
240V AC, 50/60Hz, 32V DC / 24V DC (VDE)
Operating
(As per EN 60934)
Initial insulation resistance
Dielectric strength
> 100 M ohms.
1.5 KV for One minute.
(As per EN 60934)
Characteristic
6 I ~ up to 9.0A
n
(As per EN 60934)
4 I - up to 12.0A
n
Overload Switching Capacity
Maximum Breaking Capacity
60A Max. ~ from 10.0A to 12.0A
60A Max. - from 10.0A to 12.0A
8x I for <6.0A
n
60A MAX. for > 6.0A
1 - 2 Watts
Maximum 60°C Ambient
1000 Cycles
1000 Amps PC 1
(min)
60
30
20
10
5
Power Loss
Operating Temperature
Operational Life at 2xIn
Limited short circuit current
1
0.25” Quick connect
Terminals
(S)
50
EN 60934, CSA 22.2 No. 235, UL-1077
Applicable Standards
Approvals
20
10
5
up to 16.0 A
upto 12.0A
Accessories
Dust Cover, DC-TR11 C (see page 14)
2
1
Time Current Characteristics:
The standard characteristic is valid for ambient temperatures of
+23°C. If the device is to be used in an ambient temperature other
than +23°C, allowances must be made when selecting the current
rating according to the following guidelines:
0.5
0.2
0.1
1.05 1.32
Ambient temp. °C
-20
-5
0
+10 +20
+30 +40 +50 +60
1.05 1.12 1.2 1.3
2
3
4 5
8 10
Correction Factor
0.8 0.88 0.9 0.96
1
Multiple of Rated Current
Example :
Normal Continuous Current
Ambient Temperature
:
:
:
:
:
1.8A
40°C
Rated current
Correction Factor
1.12
< 6 A
> 6 A
23°C
Recommended Current Rating
Select the nearest
1.8 x 1.12 = 2.016
Ambient
2.0A
Temperature
®
Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
16
TR-11 Characteristics
& Mounting Options
Application Examples:
Protection of single phase Motors,
Transformers, UPS, Power strips, Solenoids
etc., against damage due to overcurrent
E209569
up to 12 Amps
conditions.
Rated
Current
0.5A
0.9A
1.0A
1.2A
1.5A
1.8A
2.0A
2.2A
2.5A
2.7A
3A
Type/
Rated
Type/
Cat. No.
Current
Cat. No.
TR-11CX630.5A
TR-11CX630.9A
TR-11CX631A
TR-11CX631.2A
TR-11CX631.5A
TR-11CX631.8A
TR-11CX632A
TR-11CX632.2A
TR-11CX632.5A
TR-11CX632.7A
TR-11CX633A
TR-11CX633.3A
TR-11CX634A
TR-11CX635A
TR-11CX636A
TR-11CY636.5A
TR-11CY637A
TR-11CY638A
TR-11CY639A
TR-11CY6310A
TR-11CY6312A
TR-11CY6315A
TR-11CY6316A
3.3A
4A
Central
Wing
5A
6A
Mounting
Clips*
6.5A
7A
Standard Pack: 10
Standard Pack: 10
Weight:
Weight:
8A
0.27kg (0.6 lb.)
0.27kg (0.6 lb.)
9A
10A
12A
15A
16A
Rated
Type/
Rated
Type/
Current
Cat. No.
Current
Cat. No.
Snap
Integral
Fitting*
Mounting*
Standard Pack: 10
Standard Pack: 10
Weight:
Weight:
0.27kg (0.6 lb.)
0.27kg (0.6 lb.)
* SPECIAL ORDER ONLY. Contact Altech for more details.
PCB Mounting and additional Shunt Terminal available, please contact Altech.
®
Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
17
TR-11
Dimensions & Mounting Options
Central Mounting
DIA 4
10
9
MAXIMUM TORQUE 0.5 Nm
M10 X 1
A/F 13
PANEL CUTOUT
19
15
11
9.4
0.8
10.2
Alternate 1
Alternate 2
Wing Clips
DIA 4
DIA 12
5
.
5
1
Ø
PANEL CUTOUT
11
19
15
12.7
15.2
13.9+0.1
0.8
Snap Fitting
DIA 4
13
12
PANEL CUTOUT
X +0.1
14
21.7
11
0.8
15
Integral Mounting
DIA 4
10
9
19
15
11
0.8
Dust Cover
Cover is suitable for central mounting type
circuit breaker to provide dust & splash
protection (IP 54).
Type/Cat. No.: DC TR11 C
DIA 16
M10 X 1
Dimensions in mm (to convert to inches multiply by 0.03937)
®
Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com