VN01 015 0052 1 [AMPHENOL]
CONTACT PIN 24-28AWG CRIMP SLVR;型号: | VN01 015 0052 1 |
厂家: | Amphenol |
描述: | CONTACT PIN 24-28AWG CRIMP SLVR |
文件: | 总32页 (文件大小:3595K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Amphenol
Amphenol-Tuchel Electronics GmbH
®
C 16-3
|
C 16-L
|
Circular Connectors
www.industrial-amphenol.com
Note from the CEO
Ladies and Gentlemen,
For over 75 years Amphenol has enjoyed success as the interconnection technology
provider of choice to industry-leading companies around the world. One of our key stra-
tegic areas of focus has been and is the Industrial market. Our organization works with
leading manufacturers across a wide range of applications - including Energy Generation
& Distribution, Transportation, Heavy Equipment, Factory Automation, Wireless Outdoor,
ChipCard Readers - enabling smarter, faster and better technologies to connect pro-
ducts to customer solutions.
The Industrial market footprint of Amphenol covers over facilities in more than 12
different European countries and more than 30 countries worldwide. Our successful
expansion into new regions as well as new industrial applications is a direct reflection of
our agile, entrepreneurial management team and our unwavering commitment to execu-
te Amphenol‘s strategies for the benefit of our customers, shareholders and employees.
Thank you for partnering with Amphenol. Our entire organization is at your service.
R. Adam Norwitt
President and CEO, Amphenol Corporation
2
Make use of the best
Use our global resources
“Think global, act local!” Independently from where you are in Europe, we offer
you our global expertise and great variety of products and technologies. And in
comfort with your personal contact. Our numerous European offices are your
access to our global resources.
OUR OFFICES IN EUROPE AND WORLDWIDE
FRANCE
CHINA
KOREA
TAIWAN
AUSTRALIA
MEXICO
USA
SOUTH AFRICA
INDIA
GERMANY
UNITED KINGDOM
ITALY
SECURITY, RELIABILITY AND COMFORTABLE SERVICE FROM ONE SOURCE.
More time for important things:
benefit from our service and diversity
Enjoy security, reliability and comfortable service from one source.
INDUSTRIAL@AMPHENOL offers one of the most individual and most diversified service
programmes in the market – exclusively for industrial customers. Access all possibilities of
the Amphenol group through your personal expert adviser.
WIDE PRODUCT RANGE
EXCLUSIVENESS AND FLEXIBILITY
Take advantage of a choice of Amphenol products. Our broad
product portfolio offers individual solutions from more than 85
member companies in the global Amphenol group.
One face to the customer: every inquiry is handled on an individual
service level by your personal key account service partner. This
ensures maximum transparency and best-in-class flexibility in the
whole process.
QUALITY
INDIVIDUAL SOLUTIONS
Interconnect systems need reliability, speed and flawless data
transmission. We continuously test and guarantee the required
standard in our products – and also in our personal services.
Your project requires an individual solution that is not available off-
the-shelf? As your think tank and discussion partner we provide
engineering support and solution-oriented development for your
tailor-made Amphenol product.
SPEED AND AVAILABILITY
GLOBAL KEY ACCOUNT SERVICE
Smart and intelligent processes are the secret behind our service
programme. Flexible planning and distribution, perfect logistics and
highest availability are our key factors for best customer service.
Our key account service is your individual entrance to global
know-how, products and services. More than 85 Amphenol
companies around the world offer an extensive range of
technologies and products. We offer access to our worldwide
resources through one individual contact person.
5
6
Content
Page
Serie C 16-3
Product description
Order information Approvals
Kodiersystem
8
9
10
11
13
14
Technical data
Derating curves
View of connector style
Shell size 1
Male cable connectors
15
16
Female receptacles
Female cable connectors
Male receptacles
Accessories
17
Shell size 2
Male cable connectors
Female receptacles
18
19
20
21
Female cable connectors
Male receptacles
Accessories
Serie C 16-3
Special type 2 + PE
(Shell size 1)
Serie C 16-L
Special type 4 + PE
(Shell size 2)
22
Crimp contacts pin
23
24
25
26
27
30
31
Crimp contacts socket
Part No. system for crimp contacts
Assembly instruction
Technical Information
Remarks / Safety classification
Summary of Part Numbers
7
C 16-3
Product description
More features and advantages of Serie C16-3
When there are rough environmental conditions the series C16-3 is
in. The program includes a variety of housing types and a wide range
of contact arrangements and contact technologies. Solutions up to
900V or 50A can be realized. The housing made of high performance
composite material is extremely robust and allows a low weight of
the connector. There are versions with the proven screw terminals for
easy field installation and crimp versions for cost-effective machine
processing. The bayonet quick release allows an easy and reliable
handling of the connectors.
• Up to 20 contacts in one connector
• Hybrid inserts for combined power and signal wires
• Protection degree IP65 in mated position
• Wire gauge up to max. 6mm² / AWG10
• Encoding without loss of contact position
(on angular position of the insert)
• High-quality molded materials acc. UL94-V0
• VDE, UL and CSA approvals
8
C 16-3
Product description
Order information
Approvals
Order information
Colour coding
Crimp version
Order numbers do not include crimp contacts. Please order
separately (page 23 / 24)
Upon request the coupling ring of the plugs and the housing of
the receptacles can be delivered in the colour red, green, blue,
yellow and grey.
Crimp tooling
Ask for our catalogue “Tools”.
Polarization
Depending on the contact arrangements the polarization of this
connector series can be varied. The contact inserts can be
mounted in alternate positions. The order number in the catalogue
refers always to postition 1. The postition of the contact inserts
can also be changed by the customer using a disassembly tool
(see page 17 and 20) to remove the insert and remount it in the
required position (see page 10)
Testhouse
Approvals
Approval No.
VDE
3964
UL 1)
CSA
E 63093
48932
In general approvals refer to representative versions of the connector series and the number of contacts 8, 14, 17 and 12 + 3 for shell size 1 and
5, 12, 14 and 19 for shell size 2. Test report upon request.
1) Please refer to the „Conditions of Acceptability“.
9
C 16-3
Coding system
Polarization
Depending on the contact arrangements the polarization of this connector series can be varied.
Please take care of the housing and contact insert characteristics.
Shell size 1
Shell size 2
No of contacts
3 + PE
No of coding possibil. Position
No of contacts
4 + PE
No of coding possibil. Position
4
4
7
6
4
1,3,5,7
-
-
8 + PE
1, 3, 5, 7
5 + PE
6
7
7
6
1, 2, 3, 4, 6, 7
1, 2, 3, 4, 5, 6, 7
1, 2, 3, 4, 5, 6, 7
1, 3, 4, 5, 6, 7
14 + PE
1, 2, 3, 4, 5, 6, 7
1, 2, 3, 4, 5, 7
1, 3, 5, 7
14 + PE
17 + PE
12 + PE
12 + 3 + PE
19 + PE
Coding point on the shell
Coding point on the contact insert
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pin contact insert termination side
Pos. 5
Pos. 1
Pos. 6
Pos. 2
Pos. 7
Pos. 3
Pos. 4
Socket contact insert termination side
Pos. 5
Pos. 6
Pos. 7
Disassembly of contact inserts with disassembly tool (see page 17 and 20)
Pin or socket contact insert
Lösewerkzeuge: shell size 1, see page 17
shell size 2, see page 20
10
C 16-3
Technical data
Shell size 1
General Characteristics
Standard
Technical data
Shell size 1
17 + PE
Number of contacts
2 + PE
3 + PE
8 + PE
14 + PE
12 + 3 + PE
5
6
2
1
9
11
5
12
2
7
View on termination side
of male contact insert
13
6
7
4
2
4
11
3
8
5
15
10
13
14
8
6
12
4
14
1
10
4
1
9
16
15
3
7
3
3
2
17
10
9
5
14
3
1
8
11
8
6
13
2
12
7
1
Electrical Characteristics
Rated voltage
DIN EN 60664-11)
UL 1977, CSA 22.2
DIN EN 60664-11)
DIN EN 60664-11)
750 V
900 V
400 V
400 V
6000 V
3
100 V
3x320V,12x24V
100 V
250 V
-
6000 V
3
-
3x250V,11x250V
3 x 250 V, 12 x 24 V
Rated impulse withstand voltage
Pollution degree
8000 V
3 x 4000 V, 12 x 800 V
3000 V
3
III
3
III
II
3
III
II
3
Installation (overvoltage) category DIN EN 60664-11)
Material group
DIN EN 60664-11)
III
III
III
II
III
II
II
Current carrying capacity at +55°C DINꢀEN 60512-5-2,
Test 5b
36 A
23 A
12 A
3x 16 A, 11x 6 A 3 x 12 A, 12 x 6 A
6 A
UL 1977, CSA 22.2
-
-
10 A
3x12A,11x4A 3 x 10 A, 12 x 5 A
5 A
Insulation resistance
Contact resistance
≥ 108 Ω
≤ 5 mΩ
DINꢀEN 60512-3-1,
Test 3a
DINꢀEN 60512-2-1,
Test 2a
Climatic Characteristics
Climatic category
DINꢀEN 60068-1
40 / 125 / 56
Operating temperature
Mechanical Characteristics
Degree of protection
-40°C ... +125°C
DINꢀEN 60529
IP 65
DINꢀEN 60512-13-2,
test 13b
≤ 25 N
≤ 30 N
≤ 25 N
≤ 30 N
≤ 25 N
≤ 22 N
Insertion and withdrawal force
IEC 60512,
test 9a
≥ 500 mating cycles
Mechanical operation
Materials
Housing material
Dielectric material
Gasket material
Polyamide 6.6
Polyamide 6.6
Neoprene
silver plated / gold plated
Contact plating
Other Characteristics
Termination technique
crimp
1.5-6.0 mm2 0.5-4.0 mm2 0.14-2.5 mm2 0.09-2.5 mm2 0.09-2.5 mm2 0.09-1.0 mm2
26 - 14
16 - 10 20 - 12 28 - 14 28 - 14
28 - 18
Wire gauge
AWG
Flammability
UL 94
VO
Bajonett
Locking system
The stated technical values refer to the use as connector.
If these components are used as plug and socket device a reduced current carrying capacity has to be considered.
1)
^
^
DINꢀEN 60664-1 = VDE 0110-1 = IEC 60664-1
11
C 16-3
Technical data
Shell size 2
General Characteristics
Standard
Technical data
Shell size 1
12 + PE
19 + PE
Number of contacts
4 + PE
5 + PE
14 + PE
6
15
5
7
View on termination side
of male contact insert
4
14
16
3
4
8
13
11
17
19
5
4
6
1
9
3
18
3
2
12
7
2
1
2
1
10
14
11
10
8
13
9
12
Electrical Characteristics
Rated impulse withstand voltage
DIN EN 60664-11)
UL 1977, CSA 22.2
600 V
400 V
400 V
6000 V
3
3 x 500 V, 9 x 300 V
400 V
250 V
250 V
-
3 x 400 V, 9 x 250 V 10 x 400 V, 4 x 250 V
DIN EN 60664-11)
DIN EN 60664-11)
6000 V
Rated impulse withstand voltage
Pollution degree
Installation (overvoltage) category DIN EN 60664-11)
Material group
DIN EN 60664-11)
6000 V
3 x 6000 V, 9 x 4000 V
4000 V
3
3
III
3
III
II
3
III
II
III
III
II
II
II
Current carrying capacity at +55°C DINꢀEN 60512-5-2,
Test 5b
36 A
21 A
3 x 21 A, 9 x 11 A 4 x 6 A, 10 x 12 A
6 A
10 x 10 A, 4 x 5 A
3 x 10 A, 9 x 5 A
≥ 108 Ω
5 A
UL 1977, CSA 22.2
-
16 A
DINꢀEN 60512-3-1,
Test 3a
Insulation resistance
Contact resistance
DINꢀEN 60512-2-1,
Test 2a
≤ 5 mΩ
Climatic Characteristics
Climatic category
DINꢀEN 60068-1
25/100/56
40/100/ 56
40 / 125 / 56
Operating temperature
Mechanical Characteristics
Degree of protection
-25°C...+100°C
-40°C ... +125°C (5 + PE: +100°C)
DINꢀEN 60529
IP 65
DINꢀEN 60512-13-2,
test 13b
≤ 50 N
≤ 15 N
≤ 25 N
≤ 30 N
≤ 25 N
Insertion and withdrawal force
DINꢀEN 60512-9-1,
test 9a
≥ 250 mating
cycles
≥ 500 mating cycles
Mechanical operation
Materials
Housing material
Dielectric material
Gasket material
Polyamide 6.6
Polyamide 6.6
Neoprene
versilbert/vergoldet
Contact plating
Other Characteristics
Termination technique
screw
2.5 - 6.0 mm2
14 -10
crimp
0.09 - 2.5 mm2 0.09 - 2.5 mm2 0.09 - 1.0 mm2
Wire gauge
AWG
4 mm2
12
28 - 14
28 - 14
28 - 18
Flammability
UL 94
VO
Locking system
bayonet
The stated technical values refer to the use as connector.
If these components are used as plug and socket device a reduced current carrying capacity has to be considered.
1)
^ ^
DINꢀEN 60664-1 = VDE 0110-1 = IEC 60664-1
12
C 16-3
Derating curves
Shell size 1
2 + PE
3 + PE
8 + PE
50
45
40
35
30
25
20
15
10
5
20
18
16
14
12
10
8
6
4
2
50
45
40
35
30
25
20
15
10
5
a)
a)
b)
c)
d)
0
0
0
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
Temperature (°C)
Temperature (°C)
Temperature (°C)
all contacts ø 1,6 mm
all contacts ø 2,5 mm
all contacts ø 2,5 mm
a) wire gauge 1,5 mm2
Pin 4mm2 - Socket 6mm2
a) wire 4,0 mm2
b) wire 2,5 mm2
c) wire 1,5 mm2
d) wire 0,5 mm2
14 + PE
12 + 3 + PE
17 + PE
50
45
40
35
30
25
20
15
10
5
20
18
16
14
12
10
8
6
4
2
20
18
16
14
12
10
8
6
4
2
a)
b)
a)
b)
a)
0
0
0
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
Temperature (°C)
Temperature (°C)
Temperature (°C)
a) 4 contacts Ø 2,5 mm, wire gauge 1,5 mm2
b) 11 contacts Ø 1,5 mm, wire gauge 0,5 mm2
a) 4 contacts Ø 1,6 mm, wire gauge 1,5 mm2
b) 12 contacts Ø 1,5mm, wire gauge 0,5 mm2
all contacts ø 1,5 mm
a) wire gauge 0,5 mm2
Shell size 2
4 + PE
5 + PE
12 + PE
70
60
50
40
30
20
10
0
50
50
45
40
35
30
25
20
15
10
5
45
40
35
30
25
20
15
10
5
a)
b)
a)
b)
a)
b)
c)
0
0
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
Temperature (°C)
Temperature (°C)
Temperature (°C)
a) 4 contacts Ø 2,5 mm, wire gauge 2,5 mm2
all contacts ø 2,5 mm
all contacts ø 2,5 mm
a) wire gauge 4,0 mm 2
b) wire gauge 2,5 mm 2
b) 4 contacts loaded 4mm2
b) 9 contacts Ø 1,6 mm, wire gauge 2,5 mm2
a) 4 contacts loaded 6mm2
c) 4 contacts loaded 2,5mm2
14 + PE
19 + PE
20
18
16
14
12
10
8
20
18
16
14
12
10
8
a)
b)
a)
6
6
4
4
2
2
0
0
25 35 45 55 65 75 85 95 105 115 125
25 35 45 55 65 75 85 95 105 115 125
Temperature (°C)
Temperature (°C)
a) 11 contacts Ø 1,6 mm, wire gauge 1,5 mm2
b) 4 contacts Ø 1,5mm, wire gauge 0,5 mm2
all contacts ø 1,5 mm
a) wire gauge 0,5 mm2
13
C 16-3
View of connector style,
Shell size 1 und 2
C 16-3 Special type, 2 + PE
see page 21
C 16-L Special type, 4 + PE
see page 22
Identification
Figure
Description
Conn. Style
Page
Size 1
Size 2
Male cable connector
Long version with internal
cable clamp
15
15
15
16
16
16
16
16
17
18
I
Short version,
with clamping ring
18
18
19
19
19
18
–
H
K
E
Right -angled,
with clamping ring
Female cable connector
Long version with internal
cable clamp
Short version,
with clamping ring
D
F
Right-angled,
with clamping ring
Female receptacle
Flange mounting,
with mounted gasket
G
Panel mounting with ring
nut, with gasket
N
C
Male receptacle
Flange mounting,
with mounted gasket
19
14
C 16-3
Shell size 1
Male cable connectors
I
H
K
No. of
cont.
Description
Drawing
Contacts2)
Part No.
Cable outlet
Ø 10-12
Ø 12-14
Male cable connector for crimp,
contacts, style I,
3 + PE .N 01 025 00... C016 10I003 002 1 C016 10I003 003 1
without contacts 1)
8 + PE .N 01 016 00... C016 10I008 002 1 C016 10I008 003 1
with internal cable clamp
14 + PE 11 x
C016 10I014 002 1 C016 10I014 003 1
C016 10I015 002 C016 10I015 003 1
.N 01 015 00...
4 x
.N 01 025 00...
12+3+PE 12 x
.N 01 015 00...
4 x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10I017 002 1 C016 10I017 003 1
Cable outlet
Ø 8-10
Ø 10-12
Male cable connector for crimp
contacts, style H,
3 + PE .N 01 025 00... C016 10H003 002 1C016 10H003 003 1
without contacts 1)
8 + PE .N 01 016 00... C016 10H008 002 1C016 10H008 003 1
with clamping ring
11 x
14 + PE
12+3+PE
C016 10H014 002 1C016 10H014 003 1
.N 01 015 00...
4 x
.N 01 025 00...
C016 10H015 002 1
12 x
C016 10H015 003 1
.N 01 015 00...
4 x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10H017 002 1C016 10H017 003 1
3 + PE .N 01 025 00... C016 10K003 002 1 C016 10K003 003 1
8 + PE .N 01 016 00... C016 10K008 002 1 C016 10K008 003 1
Male cable connector for crimp
contacts, style K,
without contacts 1)
with clamping ring
14 + PE 11 x
C016 10K014 002 1 C016 10K014 003 1
.N 01 015 00...
4 x
.N 01 025 00...
12+3+PE
12 x
C016 10K015 002 1 C016 10K015 003 1
.N 01 015 00...
4 x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10K017 002 1 C016 10K017 003 1
1) Please order crimp contacts separately, see page 23/24.
2) Part No system for crimp contacts, see page 25.
15
C 16-3
–0,1
28,6
(1.126)
Shell size 1
Female receptacles
+0,2
SW27,2
(1.071)
G
Panel cutout
N
Panel cutout
Mounting hole Ø 26.2 without conception. Suitable sealing for fixing screws must be provided.
No. of
cont.
Description
Drawing
Contacts 2)
3 + PE .N 02 025 00...
Part No.
C016 10G003 000 1
Female receptacle for crimp
contacts, style G,
.N 02 016 00…
11 x .N 02 015 00...
4 x .N 02 025 00...
8 + PE
14 + PE
C016 10G008 000 1
C016 10G014 000 1
without contacts 1)
12+3+PE12 x .N 02 015 00...
4 x .N 02 016 00...
C016 10G015 000 1
17 + PE .N 02 015 00...
3 + PE .N 02 025 00...
C016 10G017 000 1
C016 10N003 006 1
Female receptacle for crimp
contacts, style N,
8 + PE .N 02 016 00...
14 + PE 11 x .N 02 015 00...
4 x .N 02 025 00...
C016 10N008 006 1
C016 10N014 006 1
without contacts 1)
12+3+PE12 x .N 02 015 00...
4 x .N 02 016 00...
17 + PE .N 02 015 00...
C016 10N015 006 1
C016 10N017 006 1
C 16-3
Shell size 1
Female cable connectors
E
D
F
Description
Drawing
No. of Contacts 2)
cont.
Part No.
Cable outlet
Ø 10-12
Ø 12-14
3 + PE .N 02 025 00... C016 10E003 002 1 C016 10E 003 0031
8 + PE .N 02 016 00..C016 10E008 002 1 C016 10E008 003 1
Female cable connector for
crimp contacts, style E,
without contacts 1),
14 + PE 11 x .N 02 015 00... C016 10E014 002 1 C016 10E014 003 1
4 x .N 02 025 00..
with internal strain relief
12+3+PE
12 x .N 02 015 00... C016 10E015 002 1 C016 10E015 003 1
4 x .N 02 016 00...
17 + PE .N 02 015 00... C016 10E017 002 1 C016 10E017 003 1
Cable outlet
Ø 8-10
Ø 10-12
3 + PE .N 02 025 00... C016 10D003 002 1 C016 10D 003 003 1
8 + PE .N 02 016 00... C016 10D008 002 1 C016 10D008 003 1
Female cable connector for
crimp contacts, style D,
without contacts 1),
14 + PE 11 x .N 02 015 00... C016 10D014 002 1 C016 10D014 003 1
4 x .N 02 025 00...
with clamping ring
C016 10D015 003 1
12+3+PE 12 x .N 02 015 00... C016 10D015 002 1
4 x .N 02 016 00...
17 + PE .N 02 015 00... C016 10D017 002 1 C016 10D017 003 1
3 + PE .N 02 025 00... C016 10F003 002 1 C016 10F003 003 1
8 + PE .N 02 016 00... C016 10F008 002 1 C016 10F008 003 1
Female cable connector for crimp
contacts, style F,
11 x .N 02 015 00...
4 x .N 02 025 00...
14 + PE
C016 10F014 002 1 C016 10F014 003 1
without contacts 1),
with clamping ring
12+3+PE 12 x .N 02 015 00... C016 10F015 002 1 C016 10F015 003 1
4 x .N 02 016 00...
17 + PE .N 02 015 0005 C016 10F017 002 1 C016 10F017 003 1
1) Please order crimp contacts separately, see page 23/24.
2) Part No system for crimp contacts, see page 25.
16
C 16-3
–0,1
28,6
(1.126)
Shell size 1
Male receptacles
C
Panel cutout
Mounting hole Ø 26.2 without conception. Suitable sealing for fixing screws must be provided.
No. of
cont.
Description
Drawing
Contacts 2)
Part No.
Male receptacle for crimp
contacts, style C,
3 + PE .N 01 025 00...
C016 10C003 000 1
without contacts 1)
8 + PE .N 01 016 00...
C016 10C008 000 1
C016 10C014 000 1
C016 10C015 000 1
C016 10C017 000 1
14 + PE 11 x .N 01 015 00...
4 x .N 01 025 00...
12 + 3 + PE 12 x .N 01 015 00...
4 x .N 01 016 00...
.N 01 015 00...
17 + PE
C 16-3
Shell size 1
Accessories
for male
for male
cable connector
receptacle
Beschreibung
Maßzeichnung
Part No.
for male cable connector for male receptacle
Protective cap for male
cable connector and male
receptacle
C016 00U000 001 1
C016 00U000 021 1
Protective cap for female
cable connector and female
receptacle
for male cable connector for male receptacle
C016 00V000 001 1
C016 00V000 021 1
Disassembly tool for
FH 0000-016
pin- and socket inserts
1) Please order crimp contacts separately, see page 23/24.
2) Part No system for crimp contacts, see page 25.
17
C 16-3
Shell size 2
Male cable connectors
I
H
K
No. of
cont.
Description
Drawing
Contacts 2)
Part No.
Cable outlet
Ø 14-16
Ø 12-14
Ø 19-21
inkl.
5 + PE
Male cable connector, style I,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1),
with internal strain relief
C016 20I005 103 2 C016 20I005 104 2 C016 20I005 105 2
9 x .N 01 016 00...
4 x .N 01 025 00...
12 + PE
C016 10I012 003 2 C016 10I012 004 2 C016 10I012 005 2
4 x .N 01 015 00...
11 x .N 01 016 00...
14 + PE
19 + PE
C016 10I014 003 2 C016 10I014 004 2 C016 10I014 005 2
.N 01 015 000...
C016 10I019 003 2 C016 10I019 004 2 C016 10I019 005 2
Cable outlet
Ø 12-14
Ø 10-12
Ø 14-18
inkl.
5 + PE
–
Male cable connector, style H
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1),
with clamping ring,
C016 20H005 103 2 C016 20H005 104 2
9 x .N 01 016 00...
4 x .N 01 025 00...
12 + PE
–
C016 10H012 003 2 C016 10H012 004 2
4 x .N 01 015 00...
11 x .N 01 016 00...
14 + PE
C016 10H014 003 2 C016 10H014 004 2 C016 10H014 005 2
.N 01 015 00...
inkl.
19 + PE
5 + PE
–
–
C016 10H019 003 2 C016 10H019 004 2
–
Male cable connector, style K
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1),
with clamping ring
C016 20K005 104 2
C016 10K012 004 2
9 x .N 01 016 00...
4 x .N 01 025 00...
12 + PE
14 + PE
19 + PE
–
–
–
–
4 x .N 01 015 00...
11 x .N 01 016 00...
–
C016 10K014 004 2
C016 10K019 004 2
.N 01 015 00...
–
C 16-3
Ø
Shell size 2
Female receptacle
Ø
G
Panel cutout
Mounting hole Ø 43.2 without conception. Suitable sealing for fixing screws must be provided.
Description
Drawing
No. of cont.
Contacts 2)
Part No.
incl.
Female receptacle, style G,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE version without contacts 1)
5 + PE
C016 20G005 100 2
C016 10G012 000 2
9 x .N 02 016 00…
4 x .N 02 025 00…
12 + PE
14 + PE
19 + PE
4 x .N 02 015 00…
11 x .N 02 016 00…
C016 10G014 000 2
C016 10G019 000 2
.N 02 015 00...
1) Please order crimp contacts separately, see page 23/24.
2) Part No system for crimp contacts, see page 25.
18
C 16-3
Shell size 2
Female cable connectors
E
D
F
No. of
cont.
Description
Drawing
Contacts 2)
Part No.
Cable outlet
Ø 14-16
Ø 12-14
Ø 19-21
incl.
5 + PE
Female cable connector, style E,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1),
with internal strain relief
C016 20E005 103 2 C016 20E005 104 2 C016 20E005 105 2
9 x .N 02 016 00…
4 x .N 02 025 00…
12 + PE
C016 10E012 003 2 C016 10E012 004 2 C016 10E012 005 2
4 x .N 02 015 00…
11 x .N 02 016 00…
14 + PE
19 + PE
C016 10E014 003 2 C016 10E014 004 2 C016 10E014 005 2
.N 02 015 00...
C016 10E019 003 2 C016 10E019 004 2 C016 10E019 005 2
Cable outlet
Ø 10-12
Ø 12-14
incl.
5 + PE
–
–
Female cable connector, style D
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1),
with clamping ring
C016 20D005 103 2 C016 20D005 104 2
9 x .N 02 016 00…
4 x .N 02 025 00…
12 + PE
C016 10D012 003 2 C016 10D012 004 2
4 x .N 02 015 00…
11 x .N 02 016 00…
14 + PE
–
C016 10D014 003 2 C016 10D014 004 2
C016 10D019 003 2 C016 10D019 004 2
.N 02 015 00...
incl.
19 + PE
5 + PE
–
–
–
–
–
C016 20F005 104 2
C016 10F012 004 2
Female cable connector, style F
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1),
with clamping ring
9 x .N 02 016 00…
4 x .N 02 025 00…
12 + PE
4 x .N 02 015 00…
11 x .N 02 016 00…
14 + PE
19 + PE
–
–
–
–
C016 10F014 004 2
C016 10F019 004 2
.N 02 015 00...
C 16-3
Ø
Shell size 2
Male receptacle
Ø
C
Panel cutout
Mounting hole Ø 43.2 without conception. Suitable sealing for fixing screws must be provided.
Description
Drawing
No. of cont.
Contacts 2)
Part No.
inkl.
Male receptacle, style C,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 +
PE-version without contacts 1)
5 + PE
C016 20C005 100 2
9 x .N 01 016 00…
4 x .N 01 025 00...
12 + PE
14 + PE
19 + PE
C016 10C012 000 2
4 x .N 01 015 00…
11 x .N 01 016 00…
C016 10C014 000 2
C016 10C019 000 2
.N 01 015 00...
1) Please order crimp contacts separately, see page 23/24.
2) Part No system for crimp contacts, see page 25.
19
C 16-3
Shell size 2
Accessories
for male
for male
receptacle
cable connector
Description
Figure
Part No.
for male cable connector
C016 00U000 011 2
for male receptacle
C016 00U000 001 2
Protective cap for male cable
connector and male receptacle
Protective cap for female cable
connector and female
receptacle
for female cable connector
C016 00V000 011 2
for female receptacle
C016 00V000 001 2
Disassembly tool for pin-and
socket inserts
FH 0002-016
20
C 16-3 2+PE
Product description
Main features and advantages of Serie C16-3 2 + PE
The C16-3 2 + PE combines the advantages of two contact technologies:
screw terminals for quick and easy (field) assembly of the female
cable connector as well as economic crimp contacts for the male
receptacle, which can be processed automatically. Based on shell
size 1 the version with 3 contacts provides an optimized bayonet
lock for IP67 in mated position and is also UV-resistant. Because of
that the up to 35A and 750V connector is particularly for outside
applications e. g. solar.
• 2 + PE with screw termination for female cable connector and
crimp termination of the male receptacle
• Up to 40A (at 40° C) and 750V
• Bayonet quick lock
• Protection degree IP67 in mated position
• Wire gauge 2.5 mm² to 6 mm² (AWG 14 – 10) for female cable
connector and 1.5 mm ² to 4 mm ² (AWG 16 - 12) for male receptacle
• Cable diameter of 8 to 14mm²
• UV resistant
• Optional locking mechanism that prevents an easy opening of the
plug connection (Secured Locking)
• VDE approval
Part No.
Description
Drawing
Polzahl Contacts2)
2 + PE incl.
8-10mm 10-12mm
12-14mm
99
[3,898]
Female cable connector
C016 20E002 801 1 C016 20E002 800 1 C016 20E002 802 1
23
[,898]
Male receptable1)
2 + PE .N 01 025 00...
C016 10P002 800 1
20,2 +0,2
15,5
[,610]
[,795] +,008
1) Please order contacts separately, see page 23/24.
2) Part No. system for contacts see page 25.
21
C 16-L
Product description
Main Features
C16-L connectors are based on C16-3 housing size 2 with 5 poles
and were developped especially for 3-phase solar inverters. The
connectors are designed for up to 50A/600V and offer an optional
locking mechanism to avoid unintended release. The screw contacts
support a fast and easy assembly in the field. Wire gauge is up to
8,3mm² (AWG 8). Another advantage is the compact design with a
diameter of only 43mm that allows a comfortable handling of the
connector.
• 4 + PE for screw termination
• Up to 50A (at +40°C) and 600V
• Bayonet locking
• IP65 when locked
• Wire gauges 2.5mm² - 8.3mm² / AWG 14 – 8
For cable diameter of 11-20mm
•
• UV resistent
• Optional locking mechanism
• VDE approval
Description
Drawing
No of
Contacts2)
Part No.
contacts
ohne Verriegelung mit Verriegelung
108
[4,262]
Female cable connector
Connector Style L
4 + PE
incl.
C016 20E004 800 2 C016 20E004 801 2
24,3
[,957]
Male receptable
Connector Style L
4 + PE
incl.
C016 20P004 800 2 C016 20P004 801 2
29,2 +0,2
22,9
[,902]
[1,150] +,008
22
16-3
Stamped single contacts Stamped contacts on reel
for hand crimping tools
Stamped contacts on reel for crimp machines
Crimp contacts
Pin
2000 pcs.
(feeding left or
right hand side)
100 resp. 200 pcs
Contact Isulation No. of cont.
Shell size Wire gauge
in mm2 /
Supplied as
pcs.
Part No.
Contact plating
silver
Ø in mm
Ø in mm
AWG
gold
1.5
1.5
1.5
1.6
1.6
1.6
2.5
0.7 - 1.6 14 + PE
12 + 3 + PE
1
1
1
2
2
0.09 - 0.25 mm2
single contact
contacts on reel
right
100
VN 01 015 0052 (1) VN 01 015 0052 (2)
ZN 01 015 0052 (1) ZN 01 015 0052 (2)
HN 01 015 0052 (1) HN 01 015 0052 (2)
TN 01 015 0052 (1) TN 01 015 0052 (2)
VN 01 015 0046 (1) VN 01 015 0046 (2)
ZN 01 015 0046 (1) ZN 01 015 0046 (2)
HN 01 015 0046 (1) HN 01 015 0046 (2)
TN 01 015 0046 (1) TN 01 015 0046 (2)
VN 01 015 0047 (1) VN 01 015 0047 (2)
ZN 01 015 0047 (1) ZN 01 015 0047 (2)
HN 01 015 0047 (1) HN 01 015 0047 (2)
TN 01 015 0047 (1) TN 01 015 0047 (2)
VN 01 016 0003 (1) VN 01 016 0003 (2)
28 - 24
200
2000
2000
100
17 + PE
14 + PE
19 + PE
left
1.3 - 2.0 14 + PE
1
1
1
2
2
0.35 - 0.5 mm2
22 - 20
single contact
contacts on reel
right
12 + 3 + PE
200
17 + PE
14 + PE
19 + PE
2000
2000
100
left
1.6 - 2.1 14 + PE
1
1
1
2
2
0.75 - 1.0 mm2
18
single contact
contacts on reel
right
12 + 3 + PE
200
17 + PE
14 + PE
19 + PE
2000
2000
100
left
1.0 - 2.0 8 + PE
1
1
2
2
0.14 - 0.5 mm2
26 - 20
single contact
contacts on reel
right
12 + 3 + PE
12 + PE
14 + PE
200
ZN 01 016 0003 (1)
ZN 01 016 0003 (2)
2000
2000
100
HN 01 016 0003 (1) HN 01 016 0003 (2)
TN 01 016 0003 (1) TN 01 016 0003 (2)
VN 01 016 0002 (1) VN 01 016 0002 (2)
left
1.8 - 2.8 8 + PE
1
1
2
2
0.5 - 1.5 mm2
20 - 16
single contact
contacts on reel
right
12 + 3 + PE
12 + PE
14 + PE
100
ZN 01 016 0002 (1)
ZN 01 016 0002 (2)
2000
2000
100
HN 01 016 0002 (1) HN 01 016 0002 (2)
TN 01 016 0002 (1) TN 01 016 0002 (2)
VN 01 016 0005 (1) VN 01 016 0005 (2)
left
2.5 - 3.5 8 + PE
1
1
2
2
1.5 - 2.5 mm2
16 - 14
single contact
contacts on reel
right
12 + 3 + PE
12 + PE
14 + PE
200
ZN 01 016 0005 (1)
ZN 01 016 0005 (2)
2000
2000
HN 01 016 0005 (1) HN 01 016 0005 (2)
TN 01 016 0005 (1) TN 01 016 0005 (2)
left
1.8 - 2.8 3 + PE
14 + PE
1
1
2
0,5 - 1,5 mm2
20 - 16
single contact
contacts on reel
right
100 VN 01 025 0001 (101) VN 01 025 0001 (102)
100
2000
2000
ZN 01 025 0001 (1)
ZN 01 025 0001 (2)
12 + PE
HN 01 025 0001 (1) HN 01 025 0001 (2)
TN 01 025 0001 (1) TN 01 025 0001 (2)
left
2.5 - 3.5 2 + PE
3 + PE
1
1
1
2
1.5 - 2.5 mm2
16 - 14
single contact
contacts on reel
right
100 VN 01 025 0010 (101) VN 01 025 0010 (102)
200
2000
2000
100
ZN 01 025 0010 (1)
ZN 01 025 0010 (2)
14 + PE
12 + PE
HN 01 025 0010 (1) HN 01 025 0010 (2)
TN 01 025 0010 (1) TN 01 025 0010 (2)
VN 01 025 0043(1)
left
2.5
3.3 - 4.2 2 + PE
3 + PE
1
1
2.5 - 4.0mm²
14-12
single contact
contacts on reel
right
200
ZN 01 025 0043 (1)
2000
2000
HN 01 025 0043 (1)
left
TN 01 025 0043 (1)
Single contact in plastic bag; stamped contact on reel
HN = feeding right side / TN = feeding left side
23
16-3
Stamped single contacts Stamped contacts on reel
for hand crimping tools
Stamped contacts on reel for crimp machines
Crimp contacts
Socket
2000 pcs.
(feeding left or
right hand side)
100 resp. 200 pcs
Contact Isulation No. of cont.
Shell size Wire gauge
in mm2 /
Supplied as
pcs.
Part No.
Contact plating
silver
Ø in mm
Ø in mm
AWG
gold
1.5
1.5
1.5
1.6
1.6
1.6
2.5
0.7 - 1.6 14 + PE
12 + 3 + PE
1
1
1
2
2
0.09 - 0.25 mm2
single contact
contacts on reel
right
100
VN 02 015 0052 (1) VN 02 015 0052 (2)
ZN 02 015 0052 (1) ZN 02 015 0052 (2)
HN 02 015 0052 (1) HN 02 015 0052 (2)
TN 02 015 0052 (1) TN 02 015 0052 (2)
VN 02 015 0046 (1) VN 02 015 0046 (2)
ZN 02 015 0046 (1) ZN 02 015 0046 (2)
HN 02 015 0046 (1) HN 02 015 0046 (2)
TN 02 015 0046 (1) TN 02 015 0046 (2)
VN 02 015 0047 (1) VN 02 015 0047 (2)
ZN 02 015 0047 (1) ZN 02 015 0047 (2)
HN 02 015 0047 (1) HN 02 015 0047 (2)
TN 02 015 0047 (1) TN 02 015 0047 (2)
VN 02 016 0003 (1) VN 02 016 0003 (2)
28 - 24
200
2000
2000
100
17 + PE
14 + PE
19 + PE
left
1.3 - 2.0 14 + PE
1
1
1
2
2
0.35 - 0.5 mm2
22 - 20
single contact
contacts on reel
right
12 + 3 + PE
200
17 + PE
14 + PE
19 + PE
2000
2000
100
left
1.6 - 2.1 14 + PE
1
1
1
2
2
0.75 - 1.0 mm2
18
single contact
contacts on reel
right
12 + 3 + PE
200
17 + PE
14 + PE
19 + PE
2000
2000
100
left
1.0 - 2.0 8 + PE
1
1
2
2
0.14 - 0.5 mm2
26 - 20
single contact
contacts on reel
right
12 + 3 + PE
12 + PE
14 + PE
200
ZN 02 016 0003 (1)
ZN 02 016 0003 (2)
2000
2000
100
HN 02 016 0003 (1) HN 02 016 0003 (2)
TN 02 016 0003 (1) TN 02 016 0003 (2)
VN 02 016 0002 (1) VN 02 016 0002 (2)
left
1.8 - 2.8 8 + PE
1
1
2
2
0.5 - 1.5 mm2
20 - 16
single contact
contacts on reel
right
12 + 3 + PE
12 + PE
14 + PE
100
ZN 02 016 0002 (1)
ZN 02 016 0002 (2)
2000
2000
100
HN 02 016 0002 (1) HN 02 016 0002 (2)
TN 02 016 0002 (1) TN 02 016 0002 (2)
VN 02 016 0005 (1) VN 02 016 0005 (2)
left
2.5 - 3.5 8 + PE
1
1
2
2
1.5 - 2.5 mm2
16 - 14
single contact
contacts on reel
right
12 + 3 + PE
12 + PE
14 + PE
200
ZN 02 016 0005 (1)
ZN 02 016 0005 (2)
2000
2000
HN 02 016 0005 (1) HN 02 016 0005 (2)
TN 02 016 0005 (1) TN 02 016 0005 (2)
left
1.8 - 2.8 3 + PE
14 + PE
1
1
2
0.5 - 1.5 mm2
20 - 16
single contact
contacts on reel
right
100 VN 02 025 0001 (101) VN 02 025 0001 (102)
100
2000
2000
ZN 02 025 0001 (1)
ZN 02 025 0001 (2)
12 + PE
HN 02 025 0001 (1) HN 02 025 0001 (2)
TN 02 025 0001 (1) TN 02 025 0001 (2)
left
2.5 - 3.5 2 + PE
3 + PE
1
1
1
2
1.5 - 2.5 mm2
16 - 14
single contact
contacts on reel
right
100 VN 02 025 0010 (101) VN 02 025 0010 (102)
200
2000
2000
100
ZN 02 025 0010 (1)
ZN 02 025 0010 (2)
14 + PE
12 + PE
HN 02 025 0010 (1) HN 02 025 0010 (2)
TN 02 025 0010 (1) TN 02 025 0010 (2)
VN 02 025 0043 (1)
left
2.5
3.3 - 4.2 2 + PE
3 + PE
1
1
2.5-4.0 mm²
14 - 12
single contact
contacts on reel
right
200
ZN 02 025 0043 (1)
2000
2000
HN 02 025 0043(1)
left
TN 02 025 0043 (1)
Single contact in plastic bag; stamped contact on reel
HN = feeding right side / TN = feeding left side
24
Part No. systems
C16-3 Part No. syntax
C016
1 0
H
014
1 0 0
1
Special
8XX = Special version
Number of
Poles
002 = 2 + PE
003 = 3 + PE
etc.
Serie
Shell size
1 = Size 1
2 = Size 2
Contact Plating
1 = silver plated
2 = gold plated
0 = without
Termination
Technique
1 = Crimp
2 = Screw
Cable entry
0 = Without
1 = PG 9
2 = PG 11
3 = PG 13,5
4 = PG 16
5 = PG 21
6 = M30x1
7 = PG 7
Polarization
0 = Standard
1 = 45°
Style
I = Male cable connector internal strain relief
H = Male cable connector cable clamp
K = Male cable connector angled
E = Female cable connector internal strain relief
D = Female cable connector cable clamp
F = Female cable connector angled
C = Male receptacle, flange
2 = 90°
3 = 135°
4 = 180°
5 = 225°
6 = 270°
P = Male receptacle, through hole
G = Female receptacle, flange
N = Male receptacle, ring nut
V = Protective cover for connectors
with female contacts
U = Protective cover for connectors
with male contacts
Part No. syntax contacts
VN 01 016 0001 (1)
__
_
_
_
_
1) 2) 3)
4)
5)
1) supplied as:
VN = single contact 100 pcs.
ZN = contacts on reel 100 resp. 200 pcs.
HN = contacts on reel with 2000 contacts (contact feeding right hand side)
TN = contacts on reel with 2000 contacts (contact feeding left hand side)
2) Type of contact:
3) Contact Ø:
01 = male contact
02 = female contact
^
e. g. 016 = 1,6 mm
4) Connection and wire gauge, e.g
0052: 0.09 - 0.25 mm2
0046: 0.35 - 0.5 mm2
0047: 0.75 - 1.0 mm2
5) Plating:
(1) = silver plated
(2) = gold plated
(4) = gold plated for high performance
25
C 16-3
C 16-L
Assembly instructions
clamping
ring
C 16-3
Shell size 1 and 2
cable nut
short back shell
long back shell
Torque for back shell and cable screw 1)
min. 1 Nm
max. 2 Nm
sealing
gasket
internal strain
relief
metal washer
male insert with
locking ring
right-angled back
shell
Shinning lengths
Screw contacts
Crimp contacts
2)
7.0+1 mm
3+0,5 mm
3+0,5 mm
3.5+1 mm
tightening torque 0,5 Nm
0.09 - 0.25 mm2
0.35 - 0.50 mm2
0.50 - 2.50 mm2
female insert with
locking ring
See assembling remarks on page 30.
C 16-L
tightening torque 1-2 Nm
tightening torque 0,7 Nm
tightening torque 5 Nm 1)
(recommended value)
cable Ø16-20mm
e
pry out inlay
See assembling remarks on page 30.
1) The tightening torque are values that may vary depending on the cable.
End splice recommended
26
2)
Technical
Information
Termination methods
• Screw connection
This comparison chart allows a cross reference between American
Wire Gauge (AWG) and metric wire sizes (mm2).
Screw clamps are designed acc. to EN 60999-1 / VDE 609-1.
Chart 1 below shows the screw size depending
on wire size and the required clamping and testing
torque..
Chart 2
AWG Wire Composition Wire diameter
Wire size
30
28
26
1 x 0.25
7 x 0.10
1 x 0.32
7 x 0.13
1 x 0.40
7 x 0.16
19 x 0.10
1 x 0.51
7 x 0.20
19 x 0.13
1 x 0.64
7 x 0.25
19 x 0.16
1 x 0.81
7 x 0.32
19 x 0.20
1 x 1.02
19 x 0.25
19 x 0.29
0.25 mm
0.36 mm
0.32 mm
0.38 mm
0.40 mm
0.48 mm
0.51 mm
0.51 mm
0.61 mm
0.64 mm
0.64 mm
0.76 mm
0.81 mm
0.81 mm
0.97 mm
1.02 mm
1.02 mm
1.27 mm
1.44 mm
0.05 mm2
0.06 mm2
0.08 mm2
0.09 mm2
0.13 mm2
0.14 mm2
0.15 mm2
0.21 mm2
0.23 mm2
0.24 mm2
0.33 mm2
0.36 mm2
0.38 mm2
0.52 mm2
0.56 mm2
0.62 mm2
0.79 mm2
0.96 mm2
1.23 mm2
Chart 1
Wire size (mm2)
Screw size
max.4
M3
Test torque(Ncm)
50
Diagram 1 below shows the range of tensile strength for a screw
connection with a clamp screw M3, fastened with a torque of 50
Ncm, depending on the wire size.
24
22
20
18
Diagram 1
16
14
12
10
8
19 x 0.36
19 x 0.46
37 x 0.40
133 x 0.29
133 x 0.36
1.80 mm
2.29 mm
3.10 mm
4.0 mm
1.95 mm2
3.09 mm2
4.60 mm2
8.80 mm2
13.5 mm2
Wire gauge
6
5.5 mm
It has to be noted that wires of the same AWG number but with
different composition have slightly different mm2.
Chart 3
Composition and Dimensions of Copper Wires
Wire Size
0.09 mm2
0.14 mm2
0.25 mm2
0.34 mm2
0.5 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4.0 mm2
6.0 mm2
10 mm2
Wire Composition Wire diameter
12 x 0.10
18 x 0.10
14 x 0.15
7 x 0.25
0.48 mm
0.50 mm
0.70 mm
0.78 mm
1.0 mm
1.2 mm
1.4 mm
1.6 mm
2.2 mm
2.8 mm
3.4 mm
4.3 mm
16 x 0.20
24 x 0.20
32 x 0.20
30 x 0.25
35 x 0.30
56 x 0.30
19 x 0.64
19 x 0.80
27
Technical
Information
• Crimp connection
Assembly instructions
A crimp connection is a non-detachable electrical connection
between a wire and a crimp contact produced with the crimp
technology. Precise crimping dies which are matched to the
crimp barrel and the wire size and a defined deformation result
in a reliable electrical connection.
For crimp contacts use the released crimp tool.
The insertion and extraction of crimp contacts shall only be
approved with the corresponding insertion / extraction tool.
There are open crimp barrels (stamped contacts) and closed
crimp barrels (turned contacts).
A detailed description of the crimp technology can be
found in our crimp tooling catalogues.
Crimp contacts are in this catalogues on page 23/24.
• Efficient termination of contacts.
• Reproducible termination achieve consistent electrical
and mechanical results
The requirements for crimp connections are defined in
DIN EN 60352-2, IEC 60352-2.
An important point of the quality of a crimp connection is the
achieved tensile strength of the termination.
Easily measured, the tensile strength is a practible means for
quality control purposes.
Diagram 2 below shows the required minimum tensile strength for
open and closed barrels depending on the wire size.
N
lb
Diagram 2
1000
4000
3000
500
400
2000
300
200
1000
500
400
100
300
50
40
200
30
100
20
50
40
10
5
30
20
mm2 0,05
AWG
0,1
28
0,2
24
0,5
20
Wire gauge in mm2 / AWG
1,0 1,5
16
14
2,5
4,0 6,0 10,0
8
26
22
12
10
18
28
Technical
Information
Chart 5
Degree of protection
2nd charact. Brief description
numeral
Definition
Electrical devices to which connectors belong to have to be protected
for safety reasons from outside influences like dust, foreign objects,
direct contact, moisture and water. This protection is provided on
industrial connectors by its housings with their latching devices and
sealed cable entries. The degree of protection can be selected depen-
ding on the type of intended use. The standard IEC 60529 and/or
DIN EN 60529 has specified the degree of protection and divided
into several classes.
The degree of protection is indicated in the following way:
IP65
Code letters
(Internat. Protection)
0
1
Non-protected
–
Protected against
vertically falling water
drops
Vertically falling drops
shall have no harmful
effects.
Vertically falling drops
shall have no harmful
effects when the
enclosure is tilted at any
angel up to 15° on either
side of the vertical.
2
3
Protected against
vertically falling water
drops when enclosure
tilted up to 15°
1st charact. numeral (degree of protection against access
gto hazardous parts and against solid foreign objects)
2nd charact. numeral (degree of protection against ingress of water)
Protected against
spraying water
Water sprayed at an angle
up to 60° on either side of
the vertical shall have no
harmful effects.
The following charts 4 and 5 give an overview about all protection
degrees.
Chart 4
4
5
6
Protected against
splashing water
Water splashed against
the enclosure from any
direction shall have no
harmful effects.
Water projected in jets
against the enclosure from
any direction shall have no
harmful effects.
Water projected in
powerful jets against
the enclosure from any
direction shall have no
harmful effects.
Intrusion of water in quan-
tities causing harmful effects
shall not be possible when
the enclosure is tempo-
ralily immersed in water
for 30 min. in 1m depth.
1st charact. Brief description
numeral
Definition
Non-protected
–
Protected against water
jets
0
1
The probe, sphere of 50mm
Ø, shall not fully penetrate
and shall have adequate
clearance from hazardous
parts.
Protected against access
to hazardous parts with
the back of a hand. Protec-
ted against solid foreign
objects of ≥50mm Ø.
Protected against
powerful water jets
2
Protected against access
to hazardous parts with a
finger. Protected against
solid foreign objects of
≥12,5mm Ø.
The jointed test finger of
12mm Ø, 80mm length, shall
have adequate clearance
from hazardous parts. The
probe, sphere of 12,5mm
Ø, shall not fully penetrate.
7
8
Protected against the
effects of temporary
immersion in water
Protected against access
to hazardous parts with
a tool. Protected against
solid foreign objects of
≥2,5mm Ø.
The probe of 2,5mm Ø
shall not penetrate at all.
3
Protected against the
effects of continous
immersion in water
Intrusion of water in
quantities causing harmful
effects shall not be possible
when the enclosure is
continuously immersed
in water under conditions
which shall be agreed
4
5
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire. not penetrate at all.
Protected against solid
foreign objects of ≥1mm Ø.
Protected against access
The probe of 1mm Ø shall
to hazardous parts with a
not penetrate.
wire. Dust-protected.
Intrusion of dust is not
totally prevented, but dust
shall not penetrate in a
quantity to interfere with
satisfactory operation of
the device or to impair
safety.
between manufacturer and
user but which are more
severe than for numeral 7.
9K 1)
Protected against water Water projected in powerful
during high pressure/
steam jet cleaning
jets with high pressure
against the enclosure from
any direction shall have no
harmful effects.
Protected against access
to hazardous parts with a
wire Dust-tight.
The probe of 1mm Ø shall
not penetrate.
No intrussion of dust.
6
1) Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code
29
Remarks
Safety classification
1. General Remarks
These connectors are designed and produced in conformity with
the low voltage directive (73/23/EWG) respectively Geräte-
sicherheitsgesetz (German law) and are especially in according
with the standards DIN EN 61984 / IEC 61984 (VDE 0627);
IEC 60664-1 (VSE 0110-1) and IEC 60529. The connectors may
be used only within the technical ratings. These connectors with /
without breaking capacity are designed and produced according
to DIN EN 61984/VDE0627.
Connectors were completely mated according to their respective
safety locking mechanism. Selection and testing of connectors with
/ without breaking capacity to meet specific product or industrial
requirements such as rated voltage and the related clearances and
creepage distances are the responsibility of the user.
3. Assembling Remarks
Protection against electrical shock of the termination of the
connectors shall be secured by correct mounting. Connectors of
the same or different series being mounted side by side may be
protected against incorrect mating by the use of coding options.
Care must be taken to ensure the parts are correctly mated and
screws are tightened with the proper torque.
All technical data refers to mated connectors under live
conditions. The safety of the connector system depends on the
correct selection of products, proper assembly of the connector
device, and a precise fit of the connectors.
2. Application Remarks
Connectors with / without breaking capacity must be used
according to specified technical ratings.
4. Termination Remarks
Cable connectors are effectively secured when using the internal
cable clamp. When the connector contains a simple gland bushing for
retention without clamping ring the cable should have a strain relief
close behind the connector. All cable properties or specifications
must be compatible with the connector design and materials.
Designated wire conductors must be terminated to the correct poles
in the connector.
The technical data represents the initial value of mated parts
under predetermined conditions and length of time. These
values could change with different test parameters or product
requirements.
The 16-3 Series connectors are used in a wide variety of industries
and equipment. Some of these include industrial machines and
controls, data processing, instrumentation and test equipment,
medical devices, telecommunication’s network and equipment,
plus outdoor and marine applications.
Crimp contacts must be fully inserted into the plastic housing and
retention assured with a slight tug on the wire.
Wire should be stripped correctly according to printed specifications
to insure no electrical contact can be made between the conductors.
There should be no nicked or cut strains during the stripping action.
All rated data for the connectors listed in this catalogues are
based on over-voltage category III 1) and pollution degree 3 2) for
electronic applications.
1)
2)
Overvoltage category III: Equipment intended for the use in installations or parts of it in which lightning overvoltages do not need to be
considered, however switching overvoltages generated by the equipment, and for cases where the reliability and the availability of the equipment
or its dependent circuits are subject to special requirements. Examples are protecting means, switches and sockets.
Pollution degree 3: Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation
which is to be expected.
30
Summary of
Part Numbers
Part Number
Page
Part Number
Page
Part Number
Page
Part Number
Page
TN 02 025 0010 (2)
TN 02 025 0043 (1)
VN 01 015 0046 (1)
VN 01 015 0046 (2)
VN 01 015 0047 (1)
VN 01 015 0047 (2)
VN 01 015 0052 (1)
VN 01 015 0052 (2)
VN 01 016 0002 (1)
VN 01 016 0002 (2)
VN 01 016 0003 (1)
VN 01 016 0003 (2)
VN 01 016 0005 (1)
VN 01 016 0005 (2)
VN 01 025 0001 (101)
VN 01 025 0001 (102)
VN 01 025 0010 (101)
VN 01 025 0010 (102)
VN 01 025 0043(1)
VN 02 015 0046 (1)
VN 02 015 0046 (2)
VN 02 015 0047 (1)
VN 02 015 0047 (2)
VN 02 015 0052 (1)
VN 02 015 0052 (2)
VN 02 016 0002 (1)
VN 02 016 0002 (2)
VN 02 016 0003 (1)
VN 02 016 0003 (2)
VN 02 016 0005 (1)
VN 02 016 0005 (2)
VN 02 025 0001 (101)
VN 02 025 0001 (102)
VN 02 025 0010 (101)
VN 02 025 0010 (102)
VN 02 025 0043 (1)
ZN 01 015 0046 (1)
ZN 01 015 0046 (2)
ZN 01 015 0047 (1)
ZN 01 015 0047 (2)
ZN 01 015 0052 (1)
ZN 01 015 0052 (2)
ZN 01 016 0002 (1)
ZN 01 016 0002 (2)
ZN 01 016 0003 (1)
ZN 01 016 0003 (2)
ZN 01 016 0005 (1)
ZN 01 016 0005 (2)
ZN 01 025 0001 (1)
ZN 01 025 0001 (2)
ZN 01 025 0010 (1)
ZN 01 025 0010 (2)
ZN 01 025 0043 (1)
ZN 02 015 0046 (1)
ZN 02 015 0046 (2)
ZN 02 015 0047 (1)
ZN 02 015 0047 (2)
ZN 02 015 0052 (1)
ZN 02 015 0052 (2)
ZN 02 016 0002 (1)
ZN 02 016 0002 (2)
ZN 02 016 0003 (1)
ZN 02 016 0003 (2)
ZN 02 016 0005 (1)
ZN 02 016 0005 (2)
ZN 02 025 0001 (1)
ZN 02 025 0001 (2)
ZN 02 025 0010 (1)
ZN 02 025 0010 (2)
ZN 02 025 0043 (1)
24
24
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
C016 20I005 105 2
C016 20K005 104 2
C016 20P004 800 2
C016 20P004 801 2
FH 0000-016
18
18
22
22
17
20
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
C016 10H003 002 1
C016 10H003 003 1
C016 10H008 002 1
C016 10H008 003 1
C016 10H012 003 2
C016 10H012 004 2
C016 10H014 002 1
C016 10H014 003 1
C016 10H014 003 2
C016 10H014 004 2
C016 10H014 005 2
C016 10H015 002 1
C016 10H015 003 1
C016 10H017 002 1
C016 10H017 003 1
C016 10H019 003 2
C016 10H019 004 2
C016 10I003 002 1
C016 10I003 003 1
C016 10I008 002 1
C016 10I008 003 1
C016 10I012 003 2
C016 10I012 004 2
C016 10I012 005 2
C016 10I014 002 1
C016 10I014 003 1
C016 10I014 003 2
C016 10I014 004 2
C016 10I014 005 2
C016 10I015 002
C016 10I015 003 1
C016 10I017 002 1
C016 10I017 003 1
C016 10I019 003 2
C016 10I019 004 2
C016 10I019 005 2
C016 10K003 002 1
C016 10K003 003 1
C016 10K008 002 1
C016 10K008 003 1
C016 10K012 004 2
C016 10K014 002 1
C016 10K014 003 1
C016 10K014 004 2
C016 10K015 002 1
C016 10K015 003 1
C016 10K017 002 1
C016 10K017 003 1
C016 10K019 004 2
C016 10N003 006 1
C016 10N008 006 1
C016 10N014 006 1
C016 10N015 006 1
C016 10N017 006 1
C016 10P002 800 1
C016 20C005 100 2
C016 20D005 103 2
C016 20D005 104 2
C016 20E002 800 1
C016 20E002 801 1
C016 20E002 802 1
C016 20E004 800 2
C016 20E004 801 2
C016 20E005 103 2
C016 20E005 104 2
C016 20E005 105 2
C016 20F005 104 2
C016 20G005 100 2
C016 20H005 103 2
C016 20H005 104 2
C016 20I005 103 2
C016 20I005 104 2
15
15
15
15
18
18
15
15
18
18
18
15
15
15
15
18
18
15
15
15
15
18
18
18
15
15
18
18
18
15
15
15
15
18
18
18
15
15
15
15
18
15
15
18
15
15
15
15
18
16
16
16
16
16
21
19
19
19
21
21
21
22
22
19
19
19
19
18
18
18
18
18
C016 00U000 001 1
C016 00U000 001 2
C016 00U000 011 2
C016 00U000 021 1
C016 00V000 001 1
C016 00V000 001 2
C016 00V000 011 2
C016 00V000 021 1
C016 10C003 000 1
C016 10C008 000 1
C016 10C012 000 2
C016 10C014 000 1
C016 10C014 000 2
C016 10C015 000 1
C016 10C017 000 1
C016 10C019 000 2
C016 10D003 002 1
C016 10D 003 003 1
C016 10D008 002 1
C016 10D008 003 1
C016 10D012 003 2
C016 10D012 004 2
C016 10D014 002 1
C016 10D014 003 1
C016 10D014 003 2
C016 10D014 004 2
C016 10D015 002 1
C016 10D015 003 1
C016 10D017 002 1
C016 10D017 003 1
C016 10D019 003 2
C016 10D019 004 2
C016 10E003 002 1
C016 10E 003 003 1
C016 10E008 002 1
C016 10E008 003 1
C016 10E012 003 2
C016 10E012 004 2
C016 10E012 005 2
C016 10E014 002 1
C016 10E014 003 1
C016 10E014 003 2
C016 10E014 004 2
C016 10E014 005 2
C016 10E015 002 1
C016 10E015 003 1
C016 10E017 002 1
C016 10E017 003 1
C016 10E019 003 2
C016 10E019 004 2
C016 10E019 005 2
C016 10F003 002 1
C016 10F003 003 1
C016 10F008 002 1
C016 10F008 003 1
C016 10F012 004 2
C016 10F014 002 1
C016 10F014 003 1
C016 10F014 004 2
C016 10F015 002 1
C016 10F015 003 1
C016 10F017 002 1
C016 10F017 003 1
C016 10F019 004 2
C016 10G003 000 1
C016 10G008 000 1
C016 10G012 000 2
C016 10G014 000 1
C016 10G014 000 2
C016 10G015 000 1
C016 10G017 000 1
C016 10G019 000 2
17
20
20
17
17
20
20
17
17
17
19
17
19
17
17
19
16
16
16
16
19
19
16
16
19
19
16
16
16
16
19
19
16
16
16
16
19
19
19
16
16
19
19
19
16
16
16
16
19
19
19
16
16
16
16
19
16
16
19
16
16
16
16
19
16
16
18
16
18
16
16
18
FH 0002-016
HN 01 015 0046 (1)
HN 01 015 0046 (2)
HN 01 015 0047 (1)
HN 01 015 0047 (2)
HN 01 015 0052 (1)
HN 01 015 0052 (2)
HN 01 016 0002 (1)
HN 01 016 0002 (2)
HN 01 016 0003 (1)
HN 01 016 0003 (2)
HN 01 016 0005 (1)
HN 01 016 0005 (2)
HN 01 025 0001 (1)
HN 01 025 0001 (2)
HN 01 025 0010 (1)
HN 01 025 0010 (2)
HN 01 025 0043 (1)
HN 02 015 0046 (1)
HN 02 015 0046 (2)
HN 02 015 0047 (1)
HN 02 015 0047 (2)
HN 02 015 0052 (1)
HN 02 015 0052 (2)
HN 02 016 0002 (1)
HN 02 016 0002 (2)
HN 02 016 0003 (1)
HN 02 016 0003 (2)
HN 02 016 0005 (1)
HN 02 016 0005 (2)
HN 02 025 0001 (1)
HN 02 025 0001 (2)
HN 02 025 0010 (1)
HN 02 025 0010 (2)
HN 02 025 0043(1)
TN 01 015 0046 (1)
TN 01 015 0046 (2)
TN 01 015 0047 (1)
TN 01 015 0047 (2)
TN 01 015 0052 (1)
TN 01 015 0052 (2)
TN 01 016 0002 (1)
TN 01 016 0002 (2)
TN 01 016 0003 (1)
TN 01 016 0003 (2)
TN 01 016 0005 (1)
TN 01 016 0005 (2)
TN 01 025 0001 (1)
TN 01 025 0001 (2)
TN 01 025 0010 (1)
TN 01 025 0010 (2)
TN 01 025 0043 (1)
TN 02 015 0046 (1)
TN 02 015 0046 (2)
TN 02 015 0047 (1)
TN 02 015 0047 (2)
TN 02 015 0052 (1)
TN 02 015 0052 (2)
TN 02 016 0002 (1)
TN 02 016 0002 (2)
TN 02 016 0003 (1)
TN 02 016 0003 (2)
TN 02 016 0005 (1)
TN 02 016 0005 (2)
TN 02 025 0001 (1)
TN 02 025 0001 (2)
TN 02 025 0010 (1)
31
International
Amphenol Argentina
Av. Callao 930
2nd Floor Office B “Plaza“
C1023 AAP Buenos Aires
Phone +54 11 4815 68 86
www.amphenol.com.ar
Argentina
Germany
Singapore
Turkey
Amphenol-Tuchel Electronics GmbH
August-Haeusser-Str. 10
74080 Heilbronn
Asia Pacific Sales Operations
72 Bendemeer Rd, No.03-32/33
Hiap Huat House, Luzerne, 339941
Singapore
Amphenol Turkey
Sun Plaza Kat: 15
Maslak Mah. Bilim Sok.No:15
34398 Sisli - Istanbul
Phone: +90 2123 679 220
www.amphenol.com.tr
Phone +49 7131 929 0
www.amphenol.de
Phone +65 6294 2128
www.amphenol.com
Australia
India
South Africa
United Kingdom
Amphenol Australia Pty. Ltd.
2 Fiveways Blvd
Amphenol Interconnect India Pvt Ltd
105, Bhosari Industrial Area
Pune – 411 026
Amphenol International Ltd
Chislehurston
Amphenol Limited
Thanet Way, Whitstable
Kent, CT53JF
Keysborough
30 Impala Road
Victoria 31 73
Phone +61 3 8796 88 88
www.amphenol.com.au
Phone +91 20 2712 04 81
www.amphenol-in.com
2196 Chislehurston
Sandton, 2146
Phone +27 11 7839 517
www.amphenol.co.za
Phone +44 1227 773 200
www.amphenol.co.uk
Brazil
Italy
Spain
USA
Amphenol do Brasil Ltda.
Rua Diogo Moreira 132, 20th Floor
CEP 05423-101 Sao Paulo SP
Phone +55 11 3815 10 03
www.amphenol.com.br
Amphenol-Tuchel Italy
Via Barbaiana n. 5
20020 Lainate (MI)
Phone +39 02 9325 41
www.amphenol.info
Amphenol Espana
Amphenol-Tuchel Electronics /
Amphenol Sine Systems
44724 Morley Drive
48036 Clinton Township, MI
Phone +1 586 913 8630
www.amphenol.info
Edificio Burgosol, Oficina 55
C/Comunidad de Madrid, 35 bis
Las Rozas (Madrid), 28230
Phone +34 91 6407 302
www.amphenol.com
China
Korea
Taiwan
Amphenol Corporation
Corporate Headquarters
358 Hall Avenue
Wallingford, CT 06492
Phone +1 877 2674 366
Phone +1 203 2658 900
www.amphenol.com
Amphenol-Tuchel Electronics
China Branch
Amphenol DaeShin Elect and
Precision Co.,Ltd
Amphenol East Asia Limited-Taiwan
5F, No. 361, Fusing 1st Rd
Gueishan Township,
20 Tianshan Road
Changzhou 213022
Phone +86 519 85 11 03 01
www.amphenol.info
558 Songnae-Dong, Sosa-Gu
Bucheon-City, Kyunggi-Do
Korea 422-130
Phone +82 32 6103 800
www.amphenol.co.kr
Taoyuan County 333
Phone +886 3 2647 200
www.amphenol.com
France
Mexico
Amphenol LTW Technology Co., Ltd.
9F, No. 657-12, Zhongzheng Road
Xinzhuang Dist., New Taipei City
242 Taiwan
Phone +886 2 2908 5626
sales@ltw-tech.com
Amphenol Socapex S.A.S.
948, Promenade de l’Arve, BP 29
Thyez Cedex, 74311
Amphenol Mexico
Prolongacion Reforma 61 - 6 B2
Col. Paseo de las Lomas
C.P. 01330 Mexico D.F.
Phone +52 55 5258 99 84
www.amphenolmexico.com
Phone +33 4 5089 28 00
www.amphenol-socapex.com
www.amphenolltw.com
More Amphenol companies can be
found here: www.amphenol.com
Important Notice
All technical data have been measured in a laboratory environment and can be different during practical usage of the product. Any product information is for descriptive usage only and not legally
binding; particularly the information does not constitute or provide any legal guaranties (“Beschaffenheitsgarantie” or “Haltbarkeitsgarantie”).
We reserve the right to change the design due to improvement in quality, development or production requirements. This catalogue must not be used in any form or manner without our prior approval
in writing (Copyright Law, Fair Trading Law, Civil Code).
Your engineering sales representative:
Amphenol-Tuchel Electronics GmbH August-Haeusser Strasse 10 74080 Heilbronn, Germany
|
|
Telephone: +49 (0)7131 929-0 Fax: +49 (0)7131 929-486 www.amphenol.info
|
|