ASD75-48S5Q [ASTRODYNE]
75 Watt ASD-Q Single Series DC/DC Converters;型号: | ASD75-48S5Q |
厂家: | ASTRODYNE CORPORATION |
描述: | 75 Watt ASD-Q Single Series DC/DC Converters |
文件: | 总4页 (文件大小:2217K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
75 Watt ASD-Q Single Series DC/DC Converters
Features
Small size 1.45”x2.28”x0.52”,
industry standard 1/4 brick
Excellent thermal performance with metal baseplate
Fast over voltage protection
Pulse-by-pulse current limiting, dead short
current limiting
Over-temperature protection
Auto-softstart
Very Low noise
Low
magnetics run cooler
Constant frequency for normal operation
Wide input voltage range
Description
Remote Sense with high regulation
Remote ON/OFF
The 75 Watt single ASD-Q series of DC/DC Converters provide
precisely regulated dc outputs. All outputs are fully isolated
from the inputs, allowing the output to be used with positive or
negative polarity and various grounding options. The ASD-Q
Series utilizes an insulated metal substrate design in an industry
standard 1/4 brick case size to meet the most rigorous require-
ments of COTS and thermally challenging industrial applications.
Super energy saving, 6 mA input idle current
Output trim with very low temperature
Water Washable, wide humidity applications
Good shock and vibration damping
Standard features include remote sensing, output trim, and
remote
Threaded-through holes are provided to allow
easy mounting or add a heat sink for extended temperature
use.
S election C hart
I in
Input R ange
ADC @
V out
VDC
I out
ADC
VDC
Model
nom
Min
Max
Typ
3.3
5
3.31
3.63
3.59
3.55
3.55
1.65
1.80
1.78
1.76
1.76
20
15
ASD75-24S3.3Q
ASD75-24S5Q
ASD75-24S12Q
ASD75-24S15Q
ASD75-24S24Q
ASD75-48S3.3Q
ASD75-48S5Q
ASD75-48S12Q
ASD75-48S15Q
ASD75-48S24Q
18
18
18
18
18
36
36
36
36
36
36
36
36
36
36
75
75
75
75
75
12
15
24
3.3
5
6.25
5
A
3.13
20
15
12
15
24
6.25
5
3.13
Default ON/OF F logic is positive.
Add -N to the model number to order negative ON/OF F logic.
375 Forbes Blvd. Mansfield, MA 02048
Ph: 800-823-8082
Fax: 508-339-0375
www.astrodyne.com
Email: sales@astrodyne.com
1
75 Watt ASD-Q Single Series DC/DC Converters
Unless otherwise stated, these
apply for ambient temperature TA=23 2°C, nominal input voltage, and rated full load. (1)
Input P arameters
ASD75-24S3.3Q
ASD75-24S5Q
ASD75-24S12Q
ASD75-24S15Q
ASD75-24S24Q
Model
Units
MIN
TYP
MAX
18
24
36
Voltage R ange
V DC
Input Overvoltage*
100 mS ec
Input R ipple R ejection
(120Hz)
MAX
TYP
50
60
V DC
dB
Undervoltage Lockout
Yes
Yes
50
3.6
Input R everse Voltage P rotection
Input C urrent No Load
100% Load
mA
A
A2 S
TYP
TYP
50
3.3
50
3.6
50
3.6
50
3.6
Inrush C urrent
MAX
0.2
R eflected R ipple, 12µH
S ource Impedance (3)
E fficiency
S witching F requency
R ecommended F use
TYP
10
mA P -P
TYP
TYP
82
84
86
360
87
87
%
kHz
(2)
AMP S
Input P arameters
Model
Units
ASD75-48S3.3Q
ASD75-48S5Q
ASD75-48S12Q
ASD75-48S15Q
ASD75-48S24Q
MIN
TYP
MAX
36
48
75
Voltage R ange
V DC
Input Overvoltage*
100 mS ec
Input R ipple R ejection
(120Hz)
MAX
TYP
85
60
V DC
dB
Undervoltage Lockout
Yes
Yes
80
1.8
Input R everse Voltage P rotection
Input C urrent No Load
100% Load
mA
A
A2 S
TYP
TYP
80
1.7
80
1.8
80
1.8
80
1.8
Inrush C urrent
MAX
0.2
R eflected R ipple, 12µH
S ource Impedance (3)
E fficiency
S witching F requency
R ecommended F use
TYP
10
mA P -P
TYP
TYP
82
84
86
360
87
87
%
kHz
(2)
AMP S
* Absolute Maximum Ratings. Caution: Stresses in excess of the Absolute Maximum Ratings can cause permanent damage to the device (see Note 1).
A
375 Forbes Blvd. Mansfield, MA 02048
Ph: 800-823-8082
Fax: 508-339-0375
www.astrodyne.com
Email: sales@astrodyne.com
75 Watt ASD-Q Single Series DC/DC Converters
Unless otherwise stated, these
apply for ambient temperature TA=23 2°C, nominal input voltage, and rated full load. (1)
Output Parameters
ASD75-24S3.3Q
ASD75-48S3.3Q
ASD75-24S5Q
ASD75-48S5Q
ASD75-24S12Q
ASD75-48S12Q
ASD75-24S15Q
ASD75-48S15Q
ASD75-24S24Q
ASD75-48S24Q
Model
Units
Output Voltage
3.3
5
12
15
24
VDC
Output Voltage
MAX
1
0
%
%
S etpoint Accuracy
Turn On Overshoot
TYP
TYP
MAX
0.005
0.01
0.003
0.005
Temperature Coefficient
%/°C
Noise (8)
R ipple
TYP
TYP
20
30
20
30
40
75
50
100
70
150
mV R MS
mV P-P
MIN
5
100
2
Load Current (4)
%
%
MAX
Load Transient Overshoot (7) TYP
Load Transient R ecovery
Time (6)
TYP
0.8
mS ec
Load R egulation (5)
Min-Max Load
Line R egulation
Vin = Min-Max
TYP
0.02
0.2
0.01
0.1
%
%
MAX
TYP
MAX
Overvoltage Protection (OVP)
Threshhold
OVP Type - Non-latching
Open Loop Overvoltage
Clamp
MIN
MAX
115
135
%
Output Current Limit
TYP
120
%
%
V out=90% of V out-nom
Output S hort Circuit Current
V out = 0.1 V
TYP
MAX
150
160
NOTES:
(9) When an external
switch is used, such as open collector
switch, logic high requires the switch to be high-impedance.
(1) Refer to the Astrodyne Application Notes for
terms, measurement circuits, and other information.
(2) Refer to the Astrodyne Application Notes for information on fusing.
For inrush current, refer to the above.
Switch leakage currents greater than 20 µA may be
trigger the to the logic-low state.
(10) Most switches would be suitable for logic
to
control, in case
there is a problem, you can make following estimation and then
leave some margin.
Whenopencollectorisusedforlogichigh,“OpenCircuitVoltage
(3) 33 µF capacitor connected to two “Input” pins. Then place
current sensor in series with 12 µH inductor between 33 µF and
the source. The
ripple current is measured over 5 Hz
A
at
Pin”, “Output Resistance” and “External Leakage
to 20 MHz bandwidth (current sensor is located between the
converter input pin and the 12 µH inductor).
Current Allowed for Logic High” are used to estimate the high
impedance requirement of open collector.
(4) Optimum performance is obtained when this power supply is
operated within the minimum to maximum load
No damage to module will occur when the output is operated at
less than minimum load, but the output voltage may contain a
low frequency component that may exceed output noise
.
When switch is used for logic low, “Open Circuit Voltage at On/
Pin”, “Output Resistance” and “LOW Logic Level” are used
to estimate the low impedance requirement of switch.
(11) Thermalimpedanceistestedwiththeconvertermountedvertically
and facing another printed circuit board 1/2 inch away. If
converter is mounted horizontally with no obstructions, thermal
impedance is approximately 10 °C/W.
(5) Load regulation is
as the output voltage change when
changing load current from maximum to minimum. The voltage
is measured at the output pin.
If heat sink is needed, apply a very thin layer of thermally
conductive grease on the metal base of converter, then properly
tighten the screws.
(6) Load Transient Recovery Time is
as the time for the
output to settle from a 50 to 75% or 25% step load change to a
1% error band of output voltage (rise time of step = 2µ Sec).
(12) Water Washability - TheseDC/DC converters are designed to
withstandmostsolder/washprocesses.Carefulattentionshould
(7) Load Transient Overshoot is
during a transient as
(8) Noise is measured per the Astrodyne Application Notes. Output
noise is measured with a 10 µF tantalum capacitor in parallel
with a 0.1 µF ceramic capacitor connected across the output to
CMN. Measurement bandwidth is 0-20 MHz.
as the peak overshoot
in the Note 6 above.
be used when assessing the applicability in your
manufacturing process. Converters are not hermetically sealed.
(13) Torque fasteners into threaded mounting inserts at 12 in. oz. or
less. Greater torque may result in damage to unit and void the
warranty.
c
375 Forbes Blvd. Mansfield, MA 02048
Ph: 800-823-8082
Fax: 508-339-0375
www.astrodyne.com
Email: sales@astrodyne.com
75 Watt ASD-Q Single Series DC/DC Converters
General S pecifications
All Models
Units
R emote ON/OFF Function
HIG H Logic Level
or Leave ON/OFF P in
Open
MIN
3.0
VDC
E xternal Leakage C urrent
Allowed for Logic High (9)
Input Diode P rotection
Voltage
LOW Logic Level
or Tie ON/OFF P in to -Input
MAX
MAX
MAX
MAX
20
50
1.0
1
µA
VDC
VDC
mA
Mechanical tolerances unless otherwise noted:
X.XX dimensions: 0.020 inches
S inking C urrent for Logic
Low
Open C ircuit Voltage at
P rimary ON/OFF P in (10)
Positive Logic
X.XXX dimensions: 0.005 inches
TYP
TYP
5.6
1.5
VDC
VDC
Negative Logic
Pin
1
Function
-INPUT
Idle C urrent
(Module is OFF)
Turn-on Time to 1% error
TYP
TYP
6
mADC
mS ec
2
ON/OFF
+INPUT
-OUTPUT
-S E NSE
TR IM
8
3
HIG H - Module ON
LOW - Module OFF
HIG H - Module OFF
LOW - Module ON
Positive Logic Option
4
5
6
Negative Logic Option
Output Voltage Trim
Trim R ange
7
8
+S E NS E
+OUTPUT
% of
Vout
MIN
MAX
10
Input R esistance
TYP
TYP
10
k Ohm
V
Open C ircuit Voltage
2.5
Output Voltage R emote S ens ing
Maximum Voltage Drops
MAX
0.5
V DC
%
on Lead
Line R egulation
under remote sensing
Load R egulation
under remote sensing
TYP
MAX
TYP
0.02
0.1
0.05
0.2
%
MAX
S ens e and Trim Limit
Maximum Output Voltage
Is olation
% of
Vout
MAX
110
Input to Output Isolation*
10µA Leakage
Vnom = 24 V models
Vnom = 48 V models
MAX
MAX
700
1544
VDC
VDC
E nvironmental
C alculated MTBF, Bellcore
Method 1, C ase 1
Baseplate Operating
Temperature R ange
>1,000,000
Hr
°C
MIN
MAX
MIN
MAX
TYP
-40
100
-40
120
9
S torage Temperature
°C
Thermal Impedance (11)
°C /W
Thermal S hutdown
Baseplate Temperature
(Auto R estart)
MIN
TYP
100
110
°C
General
C ase Dimension
Agency Approvals Pending
2.28" x 1.45" x 0.50"
UL/C UL 60950
MS 18
C hassis Mounting Kit
MAX
12 in. oz.
Torque on Mounting Inserts
* Absolute Maximum Ratings. Caution: Stresses in excess of the Absolute
Maximum Ratings can cause permanent damage to the device (see Note 1).
375 Forbes Blvd. Mansfield, MA 02048
Ph: 800-823-8082
Fax: 508-339-0375
www.astrodyne.com
Email: sales@astrodyne.com