D10BFPQ [BANNER]

D10 Expert™ Series with Bar Graph Display and Discrete Output;
D10BFPQ
型号: D10BFPQ
厂家: Banner Engineering    Banner Engineering
描述:

D10 Expert™ Series with Bar Graph Display and Discrete Output

文件: 总14页 (文件大小:432K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
D10 Expert Series with Bar Graph Display  
and Discrete Output  
Datasheet  
Advanced sensor with dual displays for use with plastic fiber optics  
Easy-to-read 8-segment light bar indicator for teach and signal strength  
readout, plus indicators for continuous readout of operating status (user  
configuration)  
Easy-to-set automatic Expert-style configuration options include Static and  
Dynamic TEACH, and Window SET, plus manual adjustment for fine tuning  
Smart gain-control algorithm to maximize performance in low-contrast  
applications  
Fast 500-microsecond sensing response with improved crosstalk avoidance  
routine (for two sensors) in Normal mode  
Selectable high-speed (HS) mode option for 200-µs response  
Extreme configuration flexibility via push buttons or a remote input wire  
Easy selection of Light/Dark Operate (LO/DO), 30 ms pulse stretcher (OFF-  
delay), and response speed, via push buttons or a remote input wire  
Models available with visible red (680 nm) or visible green (525 nm) sensing  
beam  
Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail  
Models with bussable power provide simplified wiring of up to 16 sensors and  
feature improved temperature compensation for side-by-side mounting  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to  
serious injury or death. This device does not include the self-checking redundant circuitry necessary  
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an  
energized or de-energized sensor output condition.  
Models  
1
Red Beam Models  
D10BFP  
Green Beam Models  
D10BFPG  
Description  
Cable  
Outputs  
2 m (6.5 ft) Cable  
6-pin Pico-style QD  
Standard sensor  
Bipolar NPN/PNP  
D10BFPQ  
D10BFPGQ  
Models with Bussable Power  
D10B5FP  
-
-
-
Main unit  
Sub-unit  
2 m (6.5 ft) Cable  
2 m (6.5 ft) Cable  
2 m (6.5 ft) Cable  
Bipolar NPN/PNP  
Single PNP  
D10B2PFP  
D10B2NFP  
Single NPN  
Overview  
The D10 Expert is an easy-to-use, DIN-rail-mountable fiber optic sensor. It provides high-performance sensing in low-  
contrast applications. Configuration options include Setup mode plus Static and Dynamic TEACH, and Window Set options,  
in addition to manual fine adjustment, remote programming, and security push button lockout.  
1
To order the 9 m (30 ft) cable model, add the suffix "W/30" to the cabled model number. For example, D10xFP W/30. Models  
with a quick disconnect require a mating cordset. See Accessories.  
Original Document  
117830 Rev. G  
14 November 2016  
117830  
D10 Expert Series with Bar Graph Display and Discrete Output  
Power ON LED (green)  
Output LED (yellow)  
The sensor’s compact housing has a large, easy-to-see bar  
graph display plus bright LEDs for easy programming and status  
monitoring during operation.  
Bar graph display (red)  
Switching threshold  
Configuration status  
LEDs (green)  
Standard models have bipolar outputs, one each NPN and PNP.  
Main units with bussable power have the same bipolar outputs;  
sub-units feature a single discrete output, either NPN or PNP.  
Models with bussable power are designed for use in machines  
and other applications where multiple sensors will be grouped  
tightly. They feature increased temperature compensation  
compared with standard models and reduce the amount of  
wiring necessary for such applications. An accessory clamp is  
available to secure a bank of connected sensors together on a  
DIN rail (see Accessories on page 13).  
Configuration push buttons  
Bussable power input  
port (cap supplied for  
unused port)  
Bussable power output  
port (cap supplied for  
unused port)  
Figure 1. Features  
Sensor Configuration  
Sensor configuration is accomplished via TEACH, Set, and Setup modes. After the sensing parameters are defined (using  
either TEACH or Set mode), Setup mode may be used to enable the delay, to change the light/dark operate status, or to  
select the highspeed response option (HS). Manual Adjust may be used to fine-tune the thresholds. Two push buttons,  
Dynamic (+) and Static (), or the remote wire, may be used to access and set the sensing parameters.  
Sensor sensitivity may be configured using any of three methods. A single switching threshold may be achieved using  
either Dynamic (on-the-fly) or Static TEACH; or Window SET may be used to define a sensing window, centered on a  
single sensing condition.  
Remote Configuration  
The remote configuration function may be used to configure the sensor remotely or to disable the push buttons for  
security. Connect the gray wire of the sensor to ground (0V dc), with a remote programming switch connected between  
them. Pulse the remote line according to the diagrams in the configuration procedures. The duration of the individual  
pulses is equal to the value T: 0.04 seconds T 0.8 seconds  
Returning to RUN Mode  
Some TEACH, Set, and Setup modes may be exited either after the 60-second timeout, or by exiting the process:  
In Static TEACH or Window Set mode, press and hold the Static () button (or hold the remote line) for 2 seconds.  
The sensor returns to Run mode without saving any new settings.  
In Setup mode, press and hold both the Static () and Dynamic (+) buttons (or hold the remote line) for 2  
seconds. The sensor returns to Run mode and saves the current setting.  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 117830 Rev. G  
D10 Expert Series with Bar Graph Display and Discrete Output  
Two-Point Static TEACH (Threshold)  
2nd Taught  
Condition  
1st Taught  
Condition  
Establishes a single switching threshold  
Threshold position is adjustable using “+” and “-” buttons (see  
Manual Adjust)  
Sensor positions  
threshold midway  
between taught conditions  
Static TEACH is the traditional setup method, used when two  
conditions can be presented by the user. The sensor locates a single  
sensing threshold (the switchpoint) midway between the two taught  
conditions, with the Output ON condition on one side, and the Output  
OFF condition on the other.  
Output OFF  
Output ON  
The first condition taught is the ON condition. The Output ON and OFF  
conditions can be reversed by changing Light/Dark Operate status in  
Setup mode (see Setup Mode on page 8 ).  
Darkest  
(no signal)  
Position  
adjusted by  
Manual Adjust  
Most Light  
(saturated  
signal)  
Static TEACH and Manual Adjust. Using Manual Adjust with Static  
TEACH moves the switching threshold. The lighted LED on the bar  
graph will move to exhibit the received signal, relative to the  
switchpoint.  
Figure 2. Static TEACH (Light Operate shown)  
Bar Graph LED Following TEACH  
Relative Signal Difference / Recommendation  
Excellent: Very stable operation  
6 to 8  
4 to 5  
2 to 3  
1
Good: Minor sensing variables may affect sensing reliability  
Low: Minor sensing variables may affect sensing reliability  
Unreliable: Consider an alternate sensing scheme  
1. Access the TEACH Mode.  
Method  
Action  
Result  
Power LED: OFF  
Output LED: ON  
Status LEDs: LO & DO  
alternately flash  
Press and hold the Static button > 2  
seconds.  
2
Push Button  
3
Remote Input  
No action is required; the sensor is ready for 1st TEACH condition.  
Bar graph: OFF  
2. TEACH the Output ON condition.  
Method  
Action  
Result  
a. Present the Output ON condition.  
b. Click the Static button.  
Power LED: OFF  
Output LED: Flash, then OFF  
Status LEDs: LO & DO  
alternately flash  
Bar graph: OFF  
Push Button  
a. Present the Output ON condition.  
b. Single-pulse the remote line.  
T
Remote Input  
3. TEACH the Output OFF condition.  
Method  
Action  
Result  
TEACH Accepted  
a. Present the Output OFF condition.  
b. Click the Static button.  
Power LED: ON  
Push Button  
Bar graph: One LED flashes to  
show relative contrast (good  
signal difference shown; see  
table above)  
Sensor returns to Run mode.  
TEACH Unacceptable  
a. Present the Output OFF condition.  
b. Single-pulse the remote line.  
T
Remote Input  
Power LED: OFF  
Bar graph: #1, 3, 5, 7  
alternately flash to show failure  
Sensor returns to the "TEACH Output ON  
condition".  
2
3
0.04 seconds "Click" 0.8 seconds  
0.04 seconds T 0.8 seconds  
P/N 117830 Rev. G  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
D10 Expert Series with Bar Graph Display and Discrete Output  
Dynamic TEACH and Adaptive Thresholds  
Darkest Taught  
Condition  
Lightest Taught  
Condition  
Teach on-the-fly  
Establishes a single switching threshold  
Threshold position is adjustable using “+” and “-” buttons  
(Manual Adjust)  
Sensor positions  
threshold midway  
between taught conditions  
Dynamic TEACH is best used when a machine or process may not  
be stopped for teaching. It programs the sensor during actual  
sensing conditions, taking multiple samples of the light and dark  
conditions and automatically setting the threshold at the optimum  
level.  
Output OFF  
Output ON  
Dynamic TEACH activates the sensor’s adaptive threshold system,  
which continuously tracks minimum and maximum signal levels,  
and automatically maintains centering of the switchpoint between  
the light and dark conditions. The adaptive threshold system  
remains in effect during Run mode. The adaptive routine saves to  
non-volatile memory at least once per hour.  
Darkest  
(no signal)  
Position  
adjusted by  
Manual Adjust  
Most Light  
(saturated  
signal)  
Figure 3. Dynamic TEACH (Light Operate shown)  
When Dynamic TEACH mode is used, the output ON state (Light or Dark Operate) remains as it was last programmed. To  
change the output ON state, use Setup mode.  
Dynamic TEACH and Manual Adjust  
The switchpoint may be adjusted (fine-tuned) whenever the sensor is in Run mode by clicking the “+” and “-” buttons.  
However, when a manual adjustment is made, the adaptive threshold system is disabled (cancelled).  
Bar Graph LED Following TEACH  
Relative Signal Difference / Recommendation  
Excellent: Very stable operation  
6 to 8  
4 to 5  
2 to 3  
1
Good: Minor sensing variables may affect sensing reliability  
Low: Minor sensing variables may affect sensing reliability  
Unreliable: Consider an alternate sensing scheme  
1. Access the Dynamic TEACH Mode.  
Method  
Action  
Result  
Press and hold the Dynamic push button > 2  
seconds.  
4
Power LED: OFF  
Output LED: OFF  
Bar graph: LO & DO alternately  
flash  
Push Button  
5
Remote Input  
Hold the remote line low (to ground) > 2 seconds.  
2. TEACH the sensing condition.  
Method  
Action  
Result  
Continue to hold push button and present Output  
ON and OFF conditions.  
Power LED: OFF  
Output LED: OFF  
Bar graph: LO & DO alternately  
flash  
Push Button  
Continue to hold remote line low (to ground) and  
present Output ON and OFF conditions.  
Remote Input  
3. Return to RUN Mode.  
Method  
Action  
Result  
TEACH Accepted  
Push Button  
Release the push button.  
Power LED: ON  
Bar graph: One LED flashes to  
show relative contrast (good  
signal difference shown; see  
table above)  
Sensor returns to Run mode with new  
settings.  
TEACH Not Accepted  
Remote Input  
Release the remote line/switch  
Power LED: OFF  
Bar graph: #1, 3, 5, 7  
alternately flash to show failure  
Sensor returns to Run mode without  
changing settings  
4
5
0.04 seconds "Click" 0.8 seconds  
0.04 seconds T 0.8 seconds  
4
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 117830 Rev. G  
D10 Expert Series with Bar Graph Display and Discrete Output  
Single-Point Window Set  
Sets a single ON condition that extends 12.5% above and below the taught condition  
All other conditions (lighter or darker) result in OFF output  
Sensing window size (sensitivity) is adjustable using “+” and “-” buttons (see Manual Adjust on page 8)  
Window Set is most useful when a product may not always appear in  
the same place, or when other signals may appear. Window Set  
designates a sensing window, with the Output ON condition inside  
the window, and the Output OFF conditions outside the window. The  
sensor accepts a single sensing condition, and adds switching  
thresholds above and below that condition to create a sensing  
window. Output ON and OFF conditions can be reversed by changing  
Light/Dark Operate status in Setup mode.  
Sensing window size  
adjusted by  
Manual Adjust  
Sensor positions  
window thresholds  
12.5% from the  
presented condition  
Window Set and Manual Adjust  
Output OFF  
Output ON  
Output OFF  
Using Manual Adjust with Window Set expands or contracts the size  
of the window. The lighted LEDs on the light bar separate to a  
greater or lesser extent to exhibit the relative sensing window size.  
Darkest  
(no signal)  
Condition  
Presented  
Most Light  
(saturated  
signal)  
Figure 4. Single-Point Window SET (Light Operate  
shown)  
1. Access the SET Mode.  
Method  
Action  
Result  
Power LED: OFF  
Output LED: ON (Push Button)  
Output LED: OFF (Remote)  
Status LEDs: LO & DO flash  
alternately  
6
Push Button  
Press and hold the Static button > 2 seconds.  
T
7
Remote Input  
Single-pulse the remote line.  
2. SET the sensing condition.  
Method  
Action  
Result  
Window Accepted  
a. Present the sensing condition.  
b. Double-click the Static button.  
Power LED: ON  
Push Button  
Bar graph: 2 indicators flash  
together to show Window  
accepted  
Sensor returns to Run mode with the new  
settings.  
T
T
Window Not Accepted  
a. Present sensing the condition.  
b. Double-pulse the remote line.  
Remote Input  
Power LED: OFF  
Bar graph: #1, 3, 5, 7 flash to  
show failure  
T
Sensor returns to the "SET Sensing  
condition".  
6
7
0.04 seconds "Click" 0.8 seconds  
0.04 seconds T 0.8 seconds  
P/N 117830 Rev. G  
www.bannerengineering.com - Tel: +1-763-544-3164  
5
D10 Expert Series with Bar Graph Display and Discrete Output  
Single-Point Light Set  
Sets a threshold 6.25% below the taught condition.  
Any condition darker than the threshold condition causes the  
output to change state  
Threshold position is adjustable using the “+” and “-” buttons  
(see Manual Adjust on page 8)  
Recommended for applications where only one condition is  
known, for example a stable light background with varying  
darker targets  
Threshold position  
adjusted by  
Manual Adjust  
Sensor positions the  
threshold slightly below  
the presented condition  
Output OFF  
Output ON  
A single sensing condition is presented, and the sensor positions a  
threshold 6.25% below the presented condition. When a condition  
darker than the threshold is sensed, the output either turns ON or OFF,  
depending on the Light/Dark Operate setting (see Setup Mode on page  
8).  
Darkest  
(no signal)  
Condition  
Presented  
Most Light  
(saturated  
signal)  
Light SET and Light/Dark Operate Selection  
Figure 5. Single-Point Light Set (Light Operate shown)  
In Light Operate mode, Light Set teaches the Output ON condition. In  
Dark Operate mode, Light Set teaches the Output OFF condition.  
1. Access the SET Mode.  
Method  
Action  
Result  
Power LED: OFF  
Output LED: ON (push button)  
OFF (remote line)  
Static LEDs: LO & DO  
alternately flash  
8
Push Button  
Press and hold the Static button > 2 seconds.  
T
9
Remote Input  
Single-pulse the remote line.  
2. SET the sensing condition.  
Method  
Action  
Result  
Threshold condition accepted  
a. Present the sensing condition.  
Push Button  
Power LED: ON  
Output LED: ON (push button)  
OFF (remote line)  
Bar graph: 4 indicators flash  
together  
b. Four-click the Static push button.  
Sensor returns to Run mode with the new  
settings.  
Threshold condition not accepted  
T
T
T
T
a. Present the sensing condition.  
b. Four-pulse the remote line.  
Power LED: ON  
Output LED: ON (push button)  
OFF (remote line)  
Remote Input  
T
T
T
Bar graph: #1, 3, 5, 7  
alternately flash to show failure  
Sensor returns to the "SET Sensing  
Condition".  
8
9
0.04 seconds "Click" 0.8 seconds  
0.04 seconds T 0.8 seconds  
6
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 117830 Rev. G  
D10 Expert Series with Bar Graph Display and Discrete Output  
Single-Point Dark Set  
Threshold position  
adjusted by  
Manual Adjust  
Sets a threshold 6.25% above the taught condition  
Any condition lighter than the threshold condition causes the  
output to change state  
Threshold position is adjustable using the “+” and “-” buttons  
(see Manual Adjust on page 8)  
Recommended for applications where only one condition is  
known, for example a stable dark background with varying  
lighter targets  
Sensor positions  
threshold slightly above  
the presented condition  
Output OFF  
Output ON  
A single sensing condition is presented, and the sensor positions a  
threshold 6.25% above the taught condition. When a condition lighter  
than the threshold is sensed, the output either turns ON or OFF,  
depending on the Light/Dark Operate setting (see Setup Mode on page  
8).  
Condition  
Presented  
Darkest  
(no signal)  
Most Light  
(saturated  
signal)  
Dark Set and Light/Dark Operate Selection  
Figure 6. Single-Point Dark Set (Light Operate  
shown)  
In Light Operate mode, Dark Set teaches the Output OFF condition. In  
Dark Operate mode, Dark Set teaches the Output ON condition.  
1. Access Set Mode  
Method  
Action  
Result  
Power LED: OFF  
Output LED: ON (push button)  
OFF (remote line)  
Static LEDs: LO & DO  
alternately flash  
10  
Push Button  
Press and hold the Static button > 2 seconds.  
T
11  
Remote Input  
Single-pulse the remote line.  
2. Set the sensing condition.  
Method  
Action  
Result  
Threshold Condition Accepted  
a. Present the sensing condition.  
b. Five-click the Static button.  
Power LED: ON  
Output LED: ON (push button)  
OFF (remote line)  
Bar graph: 4 indicators flash  
together  
Push Button  
The sensor returns to Run mode with the  
new settings.  
Threshold Condition Not Accepted  
T
T
T
T
T
a. Present the sensing condition.  
b. Five-pulse the remote line.  
Power LED: ON  
Output LED: ON (push button)  
OFF (remote line)  
Bar graph: #1, 3, 5, 7 flash to  
show failure  
Remote Input  
T
T
T
T
The sensor returns to the "SET Sensing  
Condition".  
10  
11  
0.04 seconds "Click" 0.8 seconds  
0.04 seconds T 0.8 seconds  
P/N 117830 Rev. G  
www.bannerengineering.com - Tel: +1-763-544-3164  
7
D10 Expert Series with Bar Graph Display and Discrete Output  
Setup Mode  
Use Setup mode to change sensor output response for:  
Light or Dark operate  
30-millisecond pulse stretcher (OFF-delay), if required  
200 μs high-speed response  
Setup status  
indicators  
If Setup mode configuration is interrupted and remains inactive  
for 60 seconds, the sensor returns to Run mode with the most  
recent settings (i.e., exits and saves current selection).  
Setup mode operates in the background, while the outputs are  
active; changes are updated instantly.  
Press and hold both  
buttons for more than  
2 seconds to access  
Setup Mode  
1. Access the Setup Mode.  
Method  
Action  
Result  
12  
Power LED: OFF  
Output LED: remains active  
Icon continue to display current  
setup  
Static LEDs: OFF  
Push Button  
Press and hold both push buttons > 2 seconds.  
T
T
13  
Remote Input  
Double-pulse the remote line.  
T
2. Select the setting combination.  
Method  
Action  
Result  
The sensor toggles through eight setting  
combinations, in the following order:  
or  
Click either push button until the LEDs show  
desired settings.  
Push Button  
LO - Normal Speed - No Delay  
(default)  
DO - Normal Speed - No Delay  
LO - High Speed - No Delay  
DO - High Speed - No Delay  
LO - Normal Speed - Delay  
DO - Normal Speed - Delay  
LO - High Speed - Delay  
Pulse the remote line until the LEDs show desired  
settings.  
NOTE: Double-pulsing  
the remote line will  
cause the setting to  
back up one step.  
Remote Input  
DO - High Speed - Delay  
3. Return to Run Mode.  
Method  
Action  
Result  
Push Button  
Press and hold both push buttons > 2 seconds.  
Hold remote the line low > 2 seconds.  
Power LED: ON  
The sensor returns to RUN mode with the  
new settings.  
2 seconds  
Remote Input  
Manual Adjust  
Manual Adjust is used during Run mode and is accomplished using the push buttons only. Its behavior depends on whether  
a switching threshold or a sensing window is used.  
Switching Threshold:  
Fine-tunes sensing sensitivity  
Press “+” to increase; press “-” to decrease  
Sensing Window:  
12  
13  
0.04 seconds "Click" 0.8 seconds  
0.04 seconds T 0.8 seconds  
8
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 117830 Rev. G  
D10 Expert Series with Bar Graph Display and Discrete Output  
Adjusts sensing window size (tolerance) for the single-point target condition  
Press “+” to increase; press “-” to decrease  
The lighted bar graph LEDs move to reflect the increase or decrease.  
Enabling or Disabling the Push Button  
In addition to its programming function, the remote line may be used to disable the push buttons for security. Disabling  
the push buttons prevents undesired tampering with the sensor configuration settings.  
1. Connect the sensor’s gray wire.  
2. Four-pulse the remote line to enable or disable the push button.  
The sensor toggles between enable and disable settings and returns to RUN mode.  
Wiring Diagrams  
Standard Models and Main Unit  
Installing Fibers  
1 - Brown  
2 - White  
3 - Blue  
4 - Black  
5 - Gray  
1
+
10-30V dc Standard Models  
12-30V dc Bussable Power Models  
3
Slides up to  
release fibers  
2
150 mA max. load  
6 - Pink (not used)  
Load  
Load  
4
5
The QD hookup is functionally  
identical. The pink wire is not used.  
Plastic fiber  
emitter port  
Remote Teach  
Plastic fiber  
receiver port  
Sub-Units  
NPN  
PNP  
12-30V dc  
Connection  
From Main  
Unit Bus  
12-30V dc  
Connection  
From Main  
Unit Bus  
+
+
4
5
4
5
Load  
Load  
Remote Teach  
Remote Teach  
P/N 117830 Rev. G  
www.bannerengineering.com - Tel: +1-763-544-3164  
9
D10 Expert Series with Bar Graph Display and Discrete Output  
Specifications  
Sensing Beam  
Output Protection  
Standard sensors: 660 nm visible red or 525 nm visible green,  
depending on model  
Protected against output short-circuit, continuous overload, transient  
over-voltages, and false pulse on power-up  
Models with bussable power: 660 nm visible red  
Output Response Time  
Supply Voltage  
500 microseconds (normal mode) or 200 microseconds (high-speed  
mode)  
Standard sensors: 10 to 30 V dc (10% maximum ripple) at less than  
45 mA exclusive of load  
Models with bussable power: 12 to 30 V dc (10% maximum ripple) at  
less than 45 mA exclusive of load  
Repeatability  
100 microseconds (normal mode) or 66 microseconds (high-speed  
mode)  
Supply Protection Circuitry  
Adjustments  
Protected against reverse polarity, over voltage, and transient voltage  
2 push buttons and remote wire  
Delay at Power Up  
Expert-style configuration (Static and Dynamic TEACH, and  
Window Set)  
Manually adjust (+/–) sensitivity (from push buttons only)  
LO/DO, OFF-delay, and response speed configurable (from  
push buttons or remote wire)  
Standard Sensors: 200 milliseconds maximum; outputs do not conduct  
during this time  
Models with Bussable Power: 850 milliseconds maximum; outputs do  
not conduct during this time  
Output Rating (Standard Sensors)  
Push button lockout (from remote wire only)  
Standard Sensors: 150 mA maximum load at 25° C (derate 1 mA per  
°C increase)  
OFF-state leakage current: < 5 μA at 30 V dc  
ON-state saturation voltage: NPN: < 200 mV at 10 mA; 1 V at 150 mA  
load; PNP: < 1 V at 10 mA; 1.5 V at 150 mA load  
Factory Default Settings: Light Operate, Normal Speed, No Delay  
Push-button or remote programming of response time, OFF-delay,  
light/dark operate, and display  
Indicators  
8-segment red bar graph: Light-to-dark signal difference relative to  
taught condition (Window Set); Sensing contrast (Static or Dynamic  
TEACH)  
Green Status Indicators: LO, DO, High Speed (HS), and OFF-Delay  
Green LED: Power ON  
Output Rating (Models with Bussable Power)  
Models with Bussable Power: 100 mA maximum load (derate 1 mA per  
°C above 30 °C)  
OFF-state leakage current: < 5 μA at 30 V dc  
ON-state saturation voltage: NPN: < 1.5 V; PNP: < 2 V  
Supply 15 V or more: up to 16 units with 100 mA outputs  
Less than 15 V supply (9 m cable): up to 4 units with 100 mA outputs;  
up to 8 units with 50 mA outputs  
Yellow LED: Output conducting  
Construction  
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear  
polycarbonate cover  
Required Overcurrent Protection  
Environmental Rating  
IEC IP50, NEMA 1  
WARNING: Electrical connections must be  
made by qualified personnel in accordance  
with local and national electrical codes and  
regulations.  
Connections  
Standard Sensors: PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 6-wire  
integral cable or integral 6-pin Pico-style quick-disconnect  
Models with Bussable Power: Main units: PVC-jacketed 2 m or 9 m  
(6.5 ft or 30 ft) 5-wire integral cable; Sub-units: PVC-jacketed 2 m or  
9 m (6.5 ft or 30 ft) 2-wire integral cable  
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Overcurrent protection may be provided with external fusing or via  
Current Limiting, Class 2 Power Supply.  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to www.bannerengineering.com.  
Operating Conditions  
Temperature: 10 °C to +55 °C (+14 °F to +131 °F)  
Storage Temperature: 20 °C to +85 °C (4 °F to +185 °F)  
90% at +55 °C maximum relative humidity (non-condensing)  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
Certifications  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
10  
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 117830 Rev. G  
D10 Expert Series with Bar Graph Display and Discrete Output  
Dimensions  
10.5 ± 0.2 mm (typ.)  
(0.41")  
7.6 mm  
0.30"  
35.9 mm  
(1.41")  
9.8 mm  
(0.39")  
Mounting Bracket  
(included)  
61.3 mm  
(2.42")  
68.1 mm  
(2.68")  
All measurements are listed in millimeters [inches], unless noted otherwise.  
Included Bracket Dimensions  
8.6 mm  
(0.34")  
M3 Hardware included:  
Lock Washer (2)  
Flat Washer (2)  
Screws (2)  
10.0 mm  
(0.39")  
5.0 mm  
(0.20")  
5.0 mm (0.20")  
2.5 mm (0.10")  
2x 3.5 mm  
(0.14")  
Hex Nuts (2)  
35.1 mm  
(1.38")  
25.4 mm  
(1.00")  
16.0 mm  
(0.63")  
15.2 mm  
(0.60")  
2 x ø3.3 mm (0.13")  
2x ø3.2 mm (0.13")  
10.0 mm  
(0.39")  
2x C'sink  
ø8.0 mm (0.31")  
3.2 mm (0.13") deep  
ø4.4 mm (0.18") thru  
P/N 117830 Rev. G  
www.bannerengineering.com - Tel: +1-763-544-3164  
11  
D10 Expert Series with Bar Graph Display and Discrete Output  
Performance Curves  
Red Beam Models  
Opposed Mode  
Diffuse Mode (Performance based on 90%  
reflectance white test card)  
10000  
1000  
1000  
100  
10  
E
X
C
E
X
C
E
S
S
1000  
100  
1000  
100  
100  
E
E
X
C
E
S
S
E
X
C
E
S
S
S
S
PBT66U  
PBT26U  
10  
PIT26U  
G
PIT66U  
G
A
I
A
PIT46U  
I
PIT16U  
10  
1
10  
1
G
A
I
G
A
I
N
N
PBT46U  
1
1
PBT16U  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
1000 mm  
(40.0")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
1000 mm  
(40.0")  
N
N
DISTANCE  
DISTANCE  
0.1 mm  
(.004")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
0.1 mm  
(.004")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
1000 mm  
(40.0")  
DISTANCE  
DISTANCE  
3.93"  
2.95"  
100 mm  
30 mm  
1.18"  
300 mm  
11.81"  
PIT66U  
75 mm  
50 mm  
25 mm  
PIT26U  
PIT16U  
20 mm  
10 mm  
0.78"  
0.39"  
0
200 mm  
100 mm  
7.87"  
3.93"  
0
15 mm  
0.59"  
0.39"  
1.97"  
0.98"  
0
10 mm  
5 mm  
PBT66U  
PBT46U  
PBT26U  
0
0
PIT46U  
0.19"  
0
0
10 mm  
20 mm  
30 mm  
0.39"  
0.78"  
1.18"  
100 mm  
200 mm  
300 mm  
3.93"  
7.87"  
11.81"  
0
PBT16U  
25 mm  
50 mm  
75 mm  
100 mm  
0.98"  
1.97"  
2.95"  
5 mm  
0.19"  
0.39"  
0.59"  
10 mm  
100 mm  
0
12 mm  
(0.47")  
24 mm  
(0.94")  
36 mm  
(1.42")  
48 mm  
(1.90")  
60 mm  
(2.36")  
0
80 mm 160 mm 240 mm 320 mm 400 mm  
3.93"  
(3.15")  
(6.30")  
(9.45") (12.59") (15.74")  
0
4 mm  
(0.15")  
8 mm  
(0.31")  
12 mm  
(0.47")  
16 mm  
(0.63")  
20 mm  
(0.78")  
0
32 mm  
(1.26")  
64 mm  
(2.52")  
96 mm 128 mm 160 mm  
(3.78") (5.04") (6.30")  
DISTANCE  
DISTANCE  
DISTANCE  
DISTANCE  
Green Beam Models  
Opposed Mode  
Diffuse Mode (Performance based on 90%  
reflectance white test card)  
1000  
1000  
1000  
100  
10  
1000  
E
X
C
E
S
S
E
X
C
E
S
S
E
X
C
E
X
C
E
S
S
100  
10  
100  
10  
100  
E
S
S
PBT66U  
10  
G
G
A
I
G
A
I
G
A
I
PIT66U  
PBT26U  
A
I
N
PIT26U  
PIT46U  
PBT46U  
N
N
N
PIT16U  
1
1
1
1
0.1 mm  
(.004")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
0.1 mm  
(.004")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
1000 mm  
(40.0")  
1 mm  
(.04")  
10 mm  
(0.4")  
100 mm  
(4.0")  
1000 mm  
(40.0")  
DISTANCE  
DISTANCE  
DISTANCE  
DISTANCE  
0.31"  
0.23"  
2.36"  
1.77"  
8 mm  
60 mm  
1.5 mm  
0.06"  
30 mm  
1.18"  
PIT26U  
PIT66U  
6 mm  
4 mm  
2 mm  
45 mm  
30 mm  
15 mm  
0
PBT66U  
1.0 mm  
0.5 mm  
0.04"  
0.02"  
0
20 mm  
10 mm  
0.78"  
0.39"  
0
0.16"  
0.08"  
0
1.18"  
0.59"  
0
PBT46U  
0
0
PBT26U  
0
PIT16U  
PIT46U  
0.5 mm  
1.0 mm  
1.5 mm  
0.02"  
0.04"  
0.02"  
10 mm  
20 mm  
30 mm  
0.39"  
0.78"  
1.18"  
2 mm  
4 mm  
6 mm  
8 mm  
0.08"  
0.16"  
0.23"  
15 mm  
30 mm  
45 mm  
60 mm  
0.59"  
1.18"  
1.77"  
0
1 mm  
(0.04")  
2 mm  
(0.08")  
3 mm  
(0.12")  
4 mm  
(0.16")  
5 mm  
(0.19")  
6 mm  
(0.23")  
0
10 mm  
(0.39")  
20 mm  
(0.78")  
30 mm  
(1.18")  
40 mm  
(1.57")  
50 mm  
(1.97")  
0.31"  
2.36"  
0
4 mm  
(0.16")  
8 mm  
(0.31")  
12 mm  
(0.47")  
16 mm  
(0.63")  
20 mm  
(0.78")  
0
24 mm  
(0.71")  
48 mm  
(1.42")  
72 mm  
(2.12")  
96 mm 120 mm  
(2.83") (3.54")  
DISTANCE  
DISTANCE  
DISTANCE  
DISTANCE  
12  
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 117830 Rev. G  
D10 Expert Series with Bar Graph Display and Discrete Output  
Accessories  
Quick Disconnect Cordsets  
6-Pin Snap-on M8/Pico-Style Cordsets  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
PKG6Z-2  
2 m (6.5 ft)  
32 Typ.  
Straight  
4
5
3
PKG6Z-9  
PKW6Z-2  
9 m (30 ft)  
2 m (6.5 ft)  
ø 9.0  
1
6
2
29 Typ.  
1 - brown  
2 = White  
3 = Blue  
4 = Black  
5 = Gray  
6 = Pink  
Right-angle  
15 Typ.  
PKW6Z-9  
9 m (30 ft)  
ø 10.9  
DIN Rail Accessories  
SA-DIN-CLAMP  
Pair of metal DIN rail end stops; slide onto DIN rail at either side of the sensor stack  
Combination (#2 Phillips, #8 standard slotted) set screw  
9.1 mm  
(0.63")  
9.1 mm  
(0.36")  
45.0 mm  
(1.77")  
SA-D10B-CAP  
Package of 5 each replacement terminal caps and plugs to cover beginning and end of stack of connected sensors.  
P/N 117830 Rev. G  
www.bannerengineering.com - Tel: +1-763-544-3164  
13  
D10 Expert Series with Bar Graph Display and Discrete Output  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.  
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty  
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,  
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE  
OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE  
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,  
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER  
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product  
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection  
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval  
by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product  
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most  
recent version of any documentation, refer to: www.bannerengineering.com.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

D10CRCW0402

Standard Thick Film Chip Resistors
VISHAY

D10CRCW0402

Standard Thick Film Chip Resistors
BOURNS

D10DNCFP

D10 Expert Series - Small Object Counter
BANNER

D10DNCFPQ

D10 Expert Series - Small Object Counter
BANNER

D10DNFP

D10 Expert™– Dual Discrete Outputs
BANNER

D10DNFPG

D10 Expert™– Dual Discrete Outputs
BANNER

D10DNFPGQ

D10 Expert™– Dual Discrete Outputs
BANNER

D10DNFPQ

D10 Expert™– Dual Discrete Outputs
BANNER

D10DPCFP

D10 Expert Series - Small Object Counter
BANNER

D10DPCFPQ

D10 Expert Series - Small Object Counter
BANNER

D10DPFP

D10 Expert™– Dual Discrete Outputs
BANNER

D10DPFPG

D10 Expert™– Dual Discrete Outputs
BANNER