D10DNCFPQ [BANNER]

D10 Expert Series - Small Object Counter;
D10DNCFPQ
型号: D10DNCFPQ
厂家: Banner Engineering    Banner Engineering
描述:

D10 Expert Series - Small Object Counter

文件: 总12页 (文件大小:653K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
D10 Expert Series - Small Object Counter  
Datasheet  
Advanced sensor for small object counting  
Easy-to-set selectable threshold with automatic compensation  
algorithm  
Automatic compensation algorithm compensates for dust or  
contamination on the fiber optic array and for ambient temperature  
changes  
16-bit microcontroller and 12-bit Analog-to-Digital converter (ADC) for  
high-performance, low-contrast sensing  
Easy-to-read 4-digit display for Health Mode, Percentage Blocked,  
Signal Level, or Counter Mode readout, plus indicators for a continuous  
readout of operating status (user configurable)  
Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail  
Single discrete output plus Health Mode output to indicate preventative  
maintenance is required  
Three-mode power and speed selection to optimize detection reliability  
Dynamic event stretcher to ensure one output per event — especially  
for gel-cap style pills  
Visible red (680 nm) sensing beam  
Models available with 2 m or 9 m (6.5 ft or 30 ft) cable or integral Pico-  
style quick-disconnect  
Sensors  
Models  
Cables  
Discrete Outputs  
D10DNCFP  
D10DNCFPQ  
D10DPCFP  
D10DPCFPQ  
2 m (6.5 ft) Cable  
6-pin Pico-style QD  
2 m (6.5 ft) Cable  
6-pin Pico-style QD  
NPN  
PNP  
Fiber Optic Arrays  
Detection Window  
Dimensions  
1
2
Models  
Fiber Exit  
Minimum Object Size  
PFCVA-10X25-S  
PFCVA-10X25-E  
PFCVA-25X25-S  
PFCVA-25X25-E  
PFCVA-34X25-S  
PFCVA-34X25-E  
Side exit  
End exit  
Side exit  
End exit  
Side exit  
End exit  
10 mm x 25 mm  
25 mm x 25 mm  
34 mm x 25 mm  
1.5 mm  
3 mm  
4 mm  
To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number. For example: D10DNCFP W/30.  
Models with a QD connector require a mating cable.  
1
Custom fiber arrays and mounting configurations are possible. Consult factory for assistance with your small object counting  
application.  
With 2% threshold offset percentage  
2
P/N 146132 Rev. D  
15 January 2014  
0
146132  
7
D10 Expert Series - Small Object Counter  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to  
serious injury or death. This device does not include the self-checking redundant circuitry necessary  
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an  
energized or de-energized sensor output condition.  
Overview  
The D10 Expert Small Object Counter sensor is a high-performance plastic  
fiber optic amplifier that has been optimized for small object counting  
using through-beam fiber optic arrays. Fiber optic arrays emit and receive  
light over an area instead of a narrow beam. Having an area of light  
makes alignment and positioning control of the object less critical than  
using single point emitter and receiver fiber optic assemblies. Because the  
object only breaks part of the fiber optic array, reliable detection requires  
very precise thresholds, an auto compensation tracking algorithm, and  
high speed electronics to make split-second decisions.  
1
2
3
The setup and configuration of the advanced D10D sensor has been  
reduced to the act of applying power to the device with the fiber optic  
assemblies rigidly mounted in position. The user also has access to a  
comprehensive collection of setup and configuration parameters through  
the sensor’s advanced setup menu, but for most applications the default  
options provide superb performance and reliability.  
Upon power-up, the clear-state light level is measured and appropriate  
switching thresholds are established, making the fiber optic sensor  
system a stable, fast, and reliable small object counter. The clear-state  
light level can be reset by performing a 2 second hold on the dynamic (+)  
push button or single-clicking the remote line.  
4
5
Continued reliable operation is ensured as the thresholds adapt to  
changing signal levels over time using Banner Engineering’s auto  
compensation tracking algorithm. The sensor continuously tracks the  
clear-state light level and makes fine adjustments to the switching  
thresholds as required because of dust or contamination building up on  
the fiber optic array and for ambient temperature changes.  
dynamic  
The sensor features either two NPN or two PNP outputs, depending on  
your model. Each output serves a different purpose. The discrete output 1  
(white wire) switches whenever an object breaks the fiber optic array and  
can be used for counting. The Health Mode output 2 (black wire) switches  
when the fiber optic array becomes contaminated to a point that the auto  
compensation tracking algorithm cannot sufficiently adjust the thresholds  
to ensure reliable detection (see Health Mode Alarm on page 3).  
6
The duration of the discrete output 1 (white wire) can be increased  
(stretched) to ensure accurate counting. The amount of increase is a user  
configurable percentage of the detection event duration; the default  
increase time is 50% more than the event duration. Banner calls this  
feature a Dynamic Event Stretcher (DES), and it prevents errant double  
counts of translucent gel-caps and other small objects of that type. The  
DES provides a “smart” OFF-delay that is independent of application  
speed and can be adjusted from 0% to 100% of the detection event  
duration.  
static  
Figure 1. D10D Features  
1. Counting output indicator  
2. Arrow icons  
3. Health mode output indicator  
4. 4-digit display  
5. Light/dark operate, clock, and lock  
icons  
6. Programming push buttons  
2
www.bannerengineering.com - tel: 763-544-3164  
P/N 146132 Rev. D  
D10 Expert Series - Small Object Counter  
Health Mode Alarm  
The Health Mode Alarm alerts you when preventative maintenance becomes necessary to ensure reliable sensing. The  
Health Mode output 2 is Active when the system is OK and operating normally. Health Mode output 2 becomes Inactive  
when the system is in a marginal state because of contamination. The system still operates normally and can detect small  
objects, but is nearing the alarm state. When the system is completely contaminated and unable to ensure reliable  
sensing, the system goes into the alarm state. In the alarm state, the discrete output 1 is forced to the blocked state and  
can no longer be used to detect small objects.  
The sensor may enter Health Mode Alarm for any of these reasons:  
1. When first powered up; the fiber optic array may already be contaminated  
2. If the Window SET procedure fails, indicating the fiber optic array is contaminated and the sensor could not set a  
valid clear-state light level for reliable detection  
3. If the fiber optic array is contaminated enough that the auto compensation tracking algorithm cannot sufficiently  
adjust the thresholds to ensure reliable detection  
4. If the fiber optic array is blocked for more than 2 seconds  
Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear-  
state light level (see Single-Point Window SET on page 7).  
Health Model Display 3  
Display Value Outputs and Indicators  
System Status  
Discrete output 1: Operational  
25 to 100  
OK: system operating normally  
Health Mode output 2: Active  
Indicators: Arrow Icons 1 & 2 GREEN  
Discrete output 1: Operational  
Marginal: System operating normally;  
preventative maintenance  
recommended  
1 to 20  
Health Mode output 2: Inactive  
Indicators: Arrow Icon 1 Green; Arrow Icon 2 Red  
Discrete output 1: Forced to Blocked State (i.e. in dark  
operate, the output is conducting)  
Alarm: System not operational; system  
maintenance required  
0
Health Mode output 2: Inactive  
Indicators: Arrow Icons 1 & 2 Red  
Programming Options  
Light/Dark Operate Selection. Toggle to select the condition for which the output will conduct: when the object is  
present or when the object is absent.  
Threshold Offset Percentage. 2%, 3%, 4%, 5%, 10%  
Dynamic Event Stretcher (DES) Selection. The output is held ON (OFF in Light Operate) for a percentage of time  
longer than the detection event duration.  
Options: 0%, 25%, 33%, 50%, 100%  
(e.g., If the Dynamic Event Stretcher was set at 50%, a 1 ms event would be stretched to 1.5 ms)  
Display Orientation. Normal or inverted  
Display Mode. Health Mode (100%–0%); Percentage Blocked (0%–100%); Signal Level (ADC value); or Counter Mode  
(0–9999)  
Power Level/Speed Selection. High-Speed (HS) (150 µs response, 50 µs repeatability); High-Power (HP) (225 µs  
response, 75 µs repeatability); or Super High-Power (SHP) (300 µs response, 100 µs repeatability)  
3
Sensor display must be in Health Mode (see Sensor Setup on page 4)  
P/N 146132 Rev. D  
www.bannerengineering.com - tel: 763-544-3164  
3
D10 Expert Series - Small Object Counter  
Factory Default Settings. The following settings are preset at the factory; revert sensor to factory defaults using  
Advanced Setup procedure (see Advanced Setup on page 6)  
Dark Operate (DO)  
50% DES  
Health Mode Display  
2% Threshold Offset Percentage  
Normal Display Orientation  
High Speed (HS)  
Sensor Programming  
Programming Procedures. Use the Dynamic (+) and Static (-) buttons to access and set programming parameters. For  
remote programming, connect a switch or digital input to the gray wire (remote line); the length of the individual pulses is  
equal to the value T when 0.04 seconds T 0.8 seconds.  
Returning to RUN mode. Exit Setup mode by stepping through the entire Setup process (see Sensor Setup on page  
4), by escaping out of the Setup process, or by exceeding the 60 second inactivity time-out. To escape out of the Setup  
process, press and hold both the Static (-) and Dynamic (+) buttons for 2 seconds. (For remote programming, press and  
hold the remote line for 2 seconds). The sensor always saves the selected settings and returns to Run mode.  
Sensor Setup  
Configures sensor display and operating parameters.  
Changes are updated instantly.  
Click Dynamic (+) or double-pulse remote line to select an option.  
Click Static (-) or single-pulse remote line to advance.  
Remote input pulse: 0.04 s T 0.8 s  
1. Access Setup mode.  
Method  
Action  
Result  
Press and hold both the Dynamic (+) and  
Static (-) buttons concurrently for more than 2  
seconds  
Arrow Icon 1 ON Red  
Arrow Icon 2 OFF  
Display shows “Threshold Offset  
Percentage” option.  
Push Button  
Remote Input  
Double-pulse the remote line  
2. Select the threshold offset percentage.  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections  
Push Button  
Click Static (-) to save selection and advance  
to “Light/Dark Operate”  
2% to 10% Threshold Offset Percentage:  
“t 2,” “t 3,” “t 4,” “t 5,” “t 10”  
Double-pulse remote line to toggle between  
selections  
Remote Input  
Single-pulse the remote line to save selection  
and advance to “Light/Dark Operate"  
4
www.bannerengineering.com - tel: 763-544-3164  
P/N 146132 Rev. D  
D10 Expert Series - Small Object Counter  
3. Select light operate or dark operate.  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections Light Operate:  
Display flashes “lo”  
L icon ON  
Push Button  
Click Static (-) to save selection and advance  
to “Dynamic Event Stretcher (DES)”  
Double-pulse remote line to toggle between  
selections  
Dark Operate:  
Display flashes “do”  
D icon ON  
Remote Input  
Single-pulse the remote line to save selection  
and advance to “Dynamic Event Stretcher  
(DES)”  
4. Select dynamic event stretcher (DES).  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections OFF (No DES):  
“d 0”  
Clock icon OFF  
Push Button  
Click Static (-) to save selection and advance  
to “Display Mode”  
Double-pulse remote line to toggle between  
selections  
25%, 33%, 50%, or 100% DES:  
“d 25,” “d 33,” “d 50,” “d 100,”  
Clock icon ON  
Remote Input  
Single-pulse the remote line to save selection  
and advance to “Display Mode”  
5. Select display mode.  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections  
Health Mode:  
Push Button  
Click Static (-) to save selection and advance  
to "Power/Speed"  
“HLth”  
Percentage Blocked: “Pctb”  
Double-pulse remote line to toggle between  
selections  
Signal Level:  
Remote Input  
Single-pulse the remote line to save selection  
and advance to “Power/Speed"  
“1234”  
Counter Mode:  
“Cntr”  
P/N 146132 Rev. D  
www.bannerengineering.com - tel: 763-544-3164  
5
D10 Expert Series - Small Object Counter  
6. Select the speed and power combination.  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections Arrow Icons 1 and 2 ON Red  
To return to Run mode, click the Static (-)  
button OR To proceed to Advanced Setup,  
quad-click Static (-) button  
High-speed (150-µs response): “HS”  
High-power (225-µs response): “HP”  
Super-high-power (300-µs response):  
Push Button  
Double-pulse the remote line to toggle  
between selections  
Remote Input  
Single-pulse the remote line to save selection  
and return to RUN mode OR Quad-click the  
remote line to proceed to Advanced Setup  
“SHP”  
See Advanced Setup on page 6.  
Advanced Setup  
Advanced adjustments to previously configured sensor display and operating parameters.  
Quad-click Static (-) or quad-pulse remote line before exiting “Speed and Power Combination” selection to enter  
this mode  
Click Dynamic (+) or double-pulse remote line to select an option.  
Click Static (-) or single-pulse remote line to advance.  
Changes are updated instantly.  
Remote input pulse: 0.04 s T 0.8 s  
1. Enter Advanced Setup mode.  
Method  
Action  
Result  
From “Power and Speed” mode, quad-click  
Static (-) button  
Arrow Icons 1 and 2 ON Red  
Display shows “Factory Default  
Settings” option.  
Push Button  
From “Power and Speed” mode, quad-pulse the  
remote line  
Remote Input  
2. Set to the factory default settings.  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections  
Returns to factory default settings  
Push Button  
Click Static (-) to advance to “Display  
Orientation”  
Factory Default Settings Not Selected:  
Display shows “Fd n”  
Double-pulse the remote line to toggle  
between selections  
Factory Default Settings Selected: Display  
Remote Input  
Single-pulse the remote line to advance to  
“Display Orientation”  
shows “Fd y”  
3. Set the display orientation.  
Method  
Action  
Result  
Click Dynamic (+) to toggle between selections Inverts display to read “upside-down”  
Push Button  
Click Static (-) to return to RUN mode  
Normal:  
Double-pulse the remote line to toggle  
between selections  
Remote Input  
Inverted:  
Single-pulse the remote line to return to RUN  
mode  
The icons do not invert.  
6
www.bannerengineering.com - tel: 763-544-3164  
P/N 146132 Rev. D  
D10 Expert Series - Small Object Counter  
Push Button Lockout  
Prevents unwanted adjustments or tampering of the push buttons.  
Push buttons can be enabled or disabled only from the remote line and only during normal RUN mode.  
Remote input pulse: 0.04 s T 0.8 s  
Method  
Action  
Result  
Not available with push-button  
programming  
Push Button  
Push Buttons Disabled  
Display flashes “loc”  
Padlock icon appears  
Sensor remains in RUN mode  
From RUN mode, quad-pulse the remote  
line to toggle between selections  
Push Buttons Enabled  
Remote Input  
Display flashes “uloc”  
Padlock icon disappears  
Sensor remains in RUN mode  
Gate Input  
The pink wire is configured as a gate input. When this wire is pulled low (e.g., to the sensor ground), it inhibits the outputs  
from switching while all other sensor functions continue to be enabled. This feature is useful for controlling when the  
outputs are allowed to change states. Gate input function response time is 1 millisecond.  
Single-Point Window SET  
A Window SET sets a single output condition that extends above  
and below the taught condition by a selectable offset percentage (2,  
3, 4, 5, or 10%).  
Taught  
Condition  
In Dark Operate, a Window SET sets a single OFF condition that  
extends above and below the taught condition. All other conditions  
Offset %  
Offset %  
(lighter or darker) result in ON output.  
In Light Operate, a Window SET sets a single ON condition that  
extends above and below the taught condition. All other conditions  
(lighter or darker) result in OFF output.  
Output ON  
Output OFF  
Sensor positions  
Output ON  
window thresholds  
from the taught  
condition  
Darkest  
(no signal)  
Most Light  
(saturated  
signal)  
Output ON and OFF conditions can be reversed by changing Light/  
Dark Operate status in SETUP mode.  
Figure 2. Single-point Window Set and Offset Percentage  
(Dark Operate Shown)  
Remote input pulse: 0.04 s T 0.8 s  
P/N 146132 Rev. D  
www.bannerengineering.com - tel: 763-544-3164  
7
D10 Expert Series - Small Object Counter  
Set Clear-State Light Level of Single-Point Window  
Result  
Method  
Action  
1. Verify the fiber optic array is clean  
and clear of any objects.  
Display turns OFF and Arrow Icons 1 and 2 toggle 3 times  
green while the sensor is optimizing system settings.  
Push Button  
2. Press and hold Dynamic (+) button  
for more than 2 seconds.  
TEACH conditions acceptable:  
Display flashes “PASS”  
Sensor returns to Run mode with new settings.  
Arrow Icons 1 and 2 turn ON Green  
Health Mode output 2 Active  
1. Make sure fiber optic array is clean  
and clear of any objects.  
Remote Input  
TEACH conditions unacceptable:  
2. Single-pulse the remote line.  
Display flashes “FAIL”  
Arrow Icons 1 and 2 turn ON Red  
Health Mode output 2 Inactive  
Wiring Diagrams  
Wiring for quick disconnect (QD) models are functionally identical.  
NPN Output Models  
PNP Output Models  
bn  
bu  
bu  
+
12–24V dc  
12–24V dc  
bn  
1
+
wh  
wh  
1
load  
load  
bk  
bk  
2
2
health  
health  
gy  
gy  
Teach  
Gate  
Teach  
pk  
pk  
Gate  
D10D...Port Locations  
Slides Up to  
Release Fibers  
Plastic Fiber Emitter Port  
Plastic Fiber Receiver Port  
8
www.bannerengineering.com - tel: 763-544-3164  
P/N 146132 Rev. D  
D10 Expert Series - Small Object Counter  
Specifications  
Required Fiber Optics  
Supply Voltage and Current  
PFCVA models (Custom fiber arrays and mounting  
configurations are possible. Consult factory for  
assistance with your small object counting  
application.)  
12 to 24 V dc (10% maximum ripple) at less than 65  
mA, exclusive of load  
Supply Protection Circuitry  
Protected against reverse polarity and transient  
voltage  
Sensing Beam  
Visible red, 680 nm  
Output Protection Circuitry  
Output Configuration  
Protected against false pulse on power-up and  
continuous short-circuit  
2 NPN or 2 PNP, depending on model  
Output Rating  
Construction  
150 mA maximum load  
Black ABS/polycarbonate alloy (UL94 V-0 rated)  
housing, clear polycarbonate cover  
OFF-state leakage current: < 10 µA at 24 V dc  
ON-state saturation voltage: NPN < 1.5 V at 150 mA  
load; PNP < 2.5 V at 150 mA load  
Environmental Rating  
NEMA 1, IEC IP50  
Output Response Time  
Operating Conditions  
Programmable, 150 µs, 225 µs, 300 µs  
NOTE: < 1 second delay on power-up; outputs do not  
conduct during this time.  
Temperature: –20 to 55 °C (–4 to 131 °F)  
Storage Temperature: –20 to 80 °C (–4 to +75 °F)  
Max. Rel. Humidity: 90% at 50 °C (non-condensing)  
Adjustments  
Push-button or remote programming of threshold  
offset percentage, light/dark operate, Dynamic Event  
Stretcher (DES), display, and power/speed  
Number of  
Devices,  
Stacked  
Ambient  
Temp Rating  
Load  
Specification  
3
7
55 °C  
50 °C  
45 °C  
150 mA  
50 mA  
50 mA  
Installation  
35 mm DIN rail or included mounting bracket  
Indicators  
10  
Four-digit digital display, 2 arrow icons, push-button  
lockout, Dynamic Event Stretcher, light/dark operate  
selection, and 2 amber output LEDs  
Connections  
Certifications  
PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 6-wire  
integral cable or integral 6-pin Pico-style quick-  
disconnect  
D10D...Sensor Dimensions  
10.5 ± 0.2 mm (typ.)  
(0.41")  
7.6 mm  
0.30"  
35.9 mm  
(1.41")  
9.8 mm  
(0.39")  
Mounting Bracket  
(included)  
61.3 mm  
(2.42")  
68.1 mm  
(2.68")  
P/N 146132 Rev. D  
www.bannerengineering.com - tel: 763-544-3164  
9
D10 Expert Series - Small Object Counter  
Included Bracket Dimensions  
M3 Hardware included:  
Lock Washer (2)  
Flat Washer (2)  
Screws (2)  
8.6 mm  
(0.34")  
10.0 mm  
(0.39")  
5.0 mm  
(0.20")  
5.0 mm (0.20")  
2.5 mm (0.10")  
2x 3.5 mm  
(0.14")  
Hex Nuts (2)  
35.1 mm  
(1.38")  
25.4 mm  
(1.00")  
16.0 mm  
15.2 mm  
(0.63")  
(0.60")  
2 x ø3.3 mm (0.13")  
2x ø3.2 mm (0.13")  
10.0 mm  
2x C’sink  
(0.39")  
ø8.0 mm (0.31")  
3.2 mm (0.13") deep  
ø4.4 mm (0.18") thru  
Fiber Optic Array Dimensions  
14.5 mm  
[0.57”]  
83 mm  
[3.27”]  
42 mm  
[1.65”]  
30 mm  
[1.18”]  
10 mm  
[0.39”]  
4x 3.2 mm dia [0.13”]  
25 mm  
[0.98”]  
75 mm  
[2.95”]  
Figure 3. PFCVA-10X25-S and PFCVA-10X25-E  
10  
www.bannerengineering.com - tel: 763-544-3164  
P/N 146132 Rev. D  
D10 Expert Series - Small Object Counter  
14.5 mm  
[0.57”]  
83 mm  
[3.27”]  
30 mm  
[1.18”]  
42 mm  
[1.65”]  
25 mm  
[0.98”]  
4x 3.2 mm dia [0.1260”]  
25 mm  
[0.98”]  
75 mm  
[2.95”]  
Figure 4. PFCVA-25X25-S and PFCVA-25X25-E  
14.5 mm  
[0.57”]  
83 mm  
[3.27”]  
25 mm  
[0.98”]  
34 mm  
[1.34”]  
30 mm  
[1.18”]  
42 mm  
[1.65”]  
4x 3.2mm dia [0.1260”]  
75 mm  
[2.95”]  
Figure 5. PFCVA-34X25-S and PFCVA-34X25-E  
P/N 146132 Rev. D  
www.bannerengineering.com - tel: 763-544-3164  
11  
D10 Expert Series - Small Object Counter  
Accessories  
6-Pin Snap-on M8/Pico-Style Cordsets  
Model  
Length  
Style  
Dimensions  
Pinout  
PKG6Z-2  
PKG6Z-9  
2 m (6.5 ft)  
9 m (30 ft)  
Straight  
ø10 mm max.  
(0.4")  
4
5
3
1
6
2
28 mm max.  
(1.1")  
PKW6Z-2  
PKW6Z-9  
2 m (6.5 ft)  
9 m (30 ft)  
Right-angle  
25 mm max.  
(1.0")  
1 - brown  
2 - white  
3 - blue  
4 - black  
5 - gray  
6 - pink  
20 mm  
(0.8")  
ø12 mm max.  
(0.5")  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.  
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty  
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,  
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE  
OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE  
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,  
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER  
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product  
previously manufactured by Banner Engineering Corp.  
www.bannerengineering.com - tel: 763-544-3164  

相关型号:

D10DNFP

D10 Expert™– Dual Discrete Outputs
BANNER

D10DNFPG

D10 Expert™– Dual Discrete Outputs
BANNER

D10DNFPGQ

D10 Expert™– Dual Discrete Outputs
BANNER

D10DNFPQ

D10 Expert™– Dual Discrete Outputs
BANNER

D10DPCFP

D10 Expert Series - Small Object Counter
BANNER

D10DPCFPQ

D10 Expert Series - Small Object Counter
BANNER

D10DPFP

D10 Expert™– Dual Discrete Outputs
BANNER

D10DPFPG

D10 Expert™– Dual Discrete Outputs
BANNER

D10DPFPGQ

D10 Expert™– Dual Discrete Outputs
BANNER

D10DPFPQ

D10 Expert™– Dual Discrete Outputs
BANNER

D10DS45

SCHOTTKY BARRIER RECTIFIERS
JINANJINGHENG

D10F

Fixed Inductors for Surface Mounting
TOKO