DEE2R-58D [BANNER]

Sure Cross® U-GAGE K50U Ultrasonic Sensor;
DEE2R-58D
型号: DEE2R-58D
厂家: Banner Engineering    Banner Engineering
描述:

Sure Cross® U-GAGE K50U Ultrasonic Sensor

文件: 总6页 (文件大小:806K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
Datasheet  
®
The Sure Cross K50U sensor works in a variety of environments to provide a measurement of the distance between the target  
and the sensor. It is designed for plug-and-play use with the Wireless Q45U Node (or any other Banner 1-wire serial node), creating  
a cost-effective and easy-to-use solution for monitoring remote or mobile tanks and totes.  
Benefits  
Monitor wirelessly to avoid long cable runs  
Threaded housing for easy installation  
Easily monitor remote and mobile tanks and totes  
Completely wireless solution with 2+ year battery life at default sample rates  
Provides a distance measurement from the target to the sensor  
Built-in temperature compensation  
Rugged design for demanding sensing environments; rated IEC IP67, NEMA 6P  
Connects using a 1-wire serial interface  
Designed to work with FlexPower 1-Wire Serial Interface Node models  
DX80N9X1S-P6 and DX80N2X1S-P6, the 10 to 30 V dc powered 1-Wire Serial  
Interface Node models DX80N9X6S-P6 and DX80N2X6S-P6, MultiHop M-H6 and  
M-H6L radios, and Wireless Q45 Sensor Nodes DX80N2Q45U and DX80N9Q45U  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or  
death. This device does not include the self-checking redundant circuitry necessary to allow its use in  
personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized  
sensor output condition.  
Models  
Model  
Range and Frequency  
Supply Voltage  
I/O  
Range: 100 mm to 1 m (3.94 in to 39.4 in)  
Freq: 224 kHz  
K50UX1ARA  
K50UX1CRA  
3.6 to 5.5 V dc or 10  
to 30 V dc  
Distance to target using  
a 1-wire serial interface  
Range: 300 mm to 3 m (11.8 in to 118 in)  
Freq: 114 kHz  
Overview  
The K50U is an easy-to-use ultrasonic sensor with extended range and built-in temperature compensation. This sensor is designed  
to interface with a Node with 1-Wire Serial Interface. To install the sensor to either the serial Node or a cable, follow these  
instructions:  
1. Align the notch in the Node’s or cable’s female connector with the key in the sensor’s male connector.  
2. Gently slide the sensor end into the Node’s or cable’s connector.  
3. Rotate the Node’s or cable’s threaded nut to tighten the sensor down. DO NOT attempt to rotate the sensor after it is  
connected to the Node’s serial port or the cable end, this will damage the sensor.  
Indicator LEDs communicate the status of the sensor. The flashing green Power LED indicates the sensor is in Run Mode (the  
sensor’s normal operating condition).  
®
Configure this sensor using the Sure Cross Sensor Configuration Tool (instruction manual 170002) and adapter cable BWA-  
USB1WIRE-001 (datasheet 170020).  
Principles of Operation  
Ultrasonic sensors emit one or multiple pulses of ultrasonic energy, which travel through the air at the speed of sound. A portion of  
this energy reflects off the target and travels back to the sensor. The sensor measures the total time required for the energy to  
reach the target and return to the sensor. The distance to the object is then calculated using the following formula: D = ct ÷ 2  
Original Document  
191599 Rev. F  
2 May 2018  
191599  
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
D = distance from the sensor to the target  
c = speed of sound in air  
t = transit time for the ultrasonic pulse  
To improve accuracy, an ultrasonic sensor may average the results of several pulses before outputting a new value.  
Temperature Effects  
The speed of sound is dependent upon the composition, pressure and temperature of the gas in which it is traveling. For most  
ultrasonic applications, the composition and pressure of the gas are relatively fixed, while the temperature may fluctuate.  
In air, the speed of sound varies with temperature according to the following approximation:  
In metric units:  
In English units:  
C
=
=
C
ft/s  
49 460 + T  
F
20 273 + T  
m/s  
C
Cm/s = speed of sound in meters per second  
TC = temperature in °C  
Cft/s = speed of sound in feet per second  
TF = temperature in °F  
Temperature Compensation  
Changes in air temperature affect the speed of sound, which in turn affects the total time for the echo measured by the sensor. An  
increase in air temperature shifts both sensing window limits closer to the sensor. Conversely, a decrease in air temperature shifts  
both limits farther away from the sensor. This shift is approximately 3.5% of the limit distance for a 20° C change in temperature.  
The K50U series ultrasonic sensors are temperature compensated, to reduce sensor errors from temperature by about 90%.  
Exposure to direct sunlight can affect the sensor’s ability to accurately compensate for changes in temperature.  
LED Indicators  
Signal LED (red)  
Power LED (green)  
Off  
Power is Off  
Sensor is operating normally (power is on, sensor is in Run mode)  
Flashing  
Serial Communications Transmit/Receive  
Intermittent Flashing  
Continuous Flashing  
Off  
Error  
Reserved  
Self-Diagnostic Error Mode—In the unlikely event of a microprocessor memory error, the Signal LED continuously flashes. If this  
occurs, the setup parameters have been lost and the sensor may be corrupt. Contact your Banner representative for further  
information.  
Sensor Configuration Tool  
The Sensor Configuration Tool offers an easy way to manage sensor parameters, retrieve data, and visually show sensor data from  
a number of different sensors. The Sensor Configuration Tool software runs on any Windows machine and uses an adapter cable  
to connect the sensor to your computer.  
Download the most recent version of the Sensor Configuration Tool from Banner Engineering's website:  
www.bannerengineering.com/wireless. The Sensor Configuration Tool currently supports the following sensors:  
Sensor Type  
Model  
USB Adapter Cable  
Temperature and Humidity M12FTH3Q and M12FT3Q  
Model BWA-HW-006: USB-to-RS-485 adapter cable OR  
Model BWA-UCT-900: USB to RS-485 adapter cable  
M12FTH4Q and M12FT4Q  
Vibration and Temperature QM42VT1  
QM42VT2  
Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable  
Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable  
Model BWA-HW-006: USB-to-RS-485 adapter cable OR  
Model BWA-UCT-900: USB to RS-485 adapter cable OR  
When updating the firmware, you must use one of the two USB to RS-485 adapter cables plus a  
splitter pigtail cable p/n 83265  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 191599 Rev. F  
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
Sensor Type  
GPS  
Model  
USB Adapter Cable  
GPS50M  
Model BWA-HW-006: USB-to-RS-485 adapter cable AND a field-wireable M12/Euro-style  
connector or connecter with pigtail OR  
Model BWA-UCT-900: USB to RS-485 adapter cable AND a field-wireable M12/Euro-style  
connector or connecter with pigtail  
U-GAGE K50U Ultrasonic  
K50UX1CRA  
K50UX2CRA  
Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable  
Model BWA-HW-006: USB-to-RS-485 adapter cable OR  
Model BWA-UCT-900: USB to RS-485 adapter cable  
K50UX1ARA  
K50UX2ARA  
Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable  
Model BWA-HW-006: USB-to-RS-485 adapter cable OR  
Model BWA-UCT-900: USB to RS-485 adapter cable  
Wiring  
This sensor is designed to be plugged directly into compatible Nodes. The Node powers the sensor and periodically requests data  
using the 1-wire serial interface. Refer to the Class I Division 2 control drawings (p/n 143086) for wiring specifications or limitations.  
5-pin M12/Euro-style Connector (Male)  
Pin  
1
Wire Color  
Brown  
White  
Blue  
Sensor Connection  
Power IN (+), 3.6 to 5.5 V dc  
1-Wire serial device select (sinking input to sensing device)  
Ground (-)  
2
1
2
3
4
5
3
4
Black  
Not used/reserved  
5
Gray  
1-Wire serial communications  
Holding Registers  
The temperature = (Modbus register value) ÷ 20. The distance (in) = (Modbus register value) ÷ 100.  
I/O Range  
Holding Register Representation  
Sensor Register  
Output Type  
Min  
0
Max  
Min (Dec)  
0
Max (Dec)  
65535  
1
2
3
4
Distance (mm)  
Temp °C  
65535  
1638.3  
1638.3  
655.35  
–1638.4  
–1638.4  
0
–32768  
–32768  
0
32767  
Temp °F  
32767  
Distance (in)  
65535  
Distance readings below 250 mm (9.84 in) for model K50UX1CRA and below 75 mm (2.95 in) for model K50UX1ARA result in a  
register value of 0. If no reflection is received because the target is too far away, the register value is an error value of 65535.  
Specifications  
Supply Voltage  
Construction  
Housing: PBT polyester  
Transducer: epoxy/ceramic composite  
Indicators  
3.6 to 5.5 V dc or 10 to 30 V dc  
Current  
Default sensing: 180 µA  
Disabled sensing: 40 µA  
Active comms: 3.3 mA  
Two LEDs  
Connection  
Integral 5-pin M12/Euro-style male quick disconnect  
P/N 191599 Rev. F  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
K50UX1CRA Performance  
Discrete Inputs  
One Sinking  
Sensing range: 300 mm to 3 m (11.8 in to 118 in)  
Ultrasonic frequency: 114 kHz  
Temperature effect: 0.02% of distance/°C  
Resolution: 0.1% of distance (1.5 mm minimum)  
Rating: 3 mA max current at 30 V dc  
ON Condition: Less than 0.7 V  
OFF Condition: Greater than 2 V or open  
K50UX1ARA Performance  
Discrete Outputs  
Sensing range: 100 mm to 1 m (3.94 in to 39.4 in)  
Ultrasonic frequency: 224 kHz  
Temperature effect: 0.02% of distance/°C  
Resolution: 0.1% of distance (1.5 mm minimum)  
Discrete Outputs. One NMOS Sinking (Not used)  
Discrete Output Rating: Less than 10 mA maximum current at 30 V; ON-  
State Saturation: Less than 0.7 V at 20 mA  
Discrete Output ON Condition. Less than 0.7 V  
Discrete Output OFF Condition. Open  
Communication Hardware  
1-wire serial interface  
Baud Rates: 9.6k, 19.2k (default), or 38.4k  
Data Format: 8 data bits, No parity (default), even parity, or odd parity  
1 stop bit  
Communication Protocol  
Compatible Nodes  
Sure Cross DX80 Sensor Node 1-Wire Serial Interface  
900 MHz Models  
DX80N9X1S-P6  
2.4 GHz Models  
DX80N2X1S-P6  
Communications Line  
Level Receive ON: Greater than 2 V  
Level Receive OFF: Less than 0.7 V  
Level Transmit ON: 2.7 to 3 V  
DX80N9X6S-P6  
DX80DR9M-H6 and -H6L  
DX80N9Q45U  
DX80N2X6S-P6  
DX80DR2M-H6 and -H6L  
DX80N2Q45U  
Level Transmit OFF: 0 V (pulldown resistor of 10 kOhm)  
Environmental Rating1  
Vibration and Mechanical Shock  
Leakproof design, rated IEC IP67 (NEMA 6)  
All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz  
maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum  
acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms  
duration, half sine wave) requirements.  
Operating Conditions  
–40 °C to +70 °C (–40 °F to +158 °F)  
95% at +50 °C maximum relative humidity (non-condensing)  
Certifications  
Dimensions  
59.5 mm  
[2.34”]  
19 mm  
[0.75”]  
20 mm  
[0.79]  
27.5 mm  
[1.08”]  
50 mm  
[1.97”]  
M30 x 1.5  
1 1/4-11.5 NPT  
All measurements are listed in millimeters [inches], unless noted otherwise.  
1
Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.  
www.bannerengineering.com - Tel: +1-763-544-3164  
4
P/N 191599 Rev. F  
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
Performance Curves  
1 Meter Models  
With Plate Target (Typical)  
With Rod Target (Typical)  
Maximum Target Rotation Angle  
30  
20  
200  
150  
100  
50  
8.0 in  
6.0 in  
4.0 in  
2.0 in  
0
200  
150  
100  
50  
8.0 in  
6.0 in  
4.0 in  
2.0 in  
0
10  
100 x 100 mm  
25 mm Rod  
Target Rotation  
(Degrees)  
0
0
0
10  
20  
30  
10 mm Rod  
10 x 10 mm  
50  
2.0 in  
4.0 in  
6.0 in  
8.0 in  
50  
2.0 in  
4.0 in  
6.0 in  
8.0 in  
100  
150  
200  
100  
150  
200  
0
500 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm  
(20.0")  
(40.0")  
(60.0")  
(80.0")  
(100.0")  
(120.0")  
Distance  
0
200 mm  
(8.0 in)  
400 mm  
(16.0 in)  
600 mm  
(24.0 in)  
800 mm  
(32.0 in)  
1000 mm  
(40.0 in)  
0
200 mm  
(8.0 in)  
400 mm  
(16.0 in)  
600 mm  
(24.0 in)  
800 mm  
(32.0 in)  
1000 mm  
(40.0 in)  
DISTANCE  
DISTANCE  
3 Meter Models  
With Plate Target (Typical)  
With Rod Target (Typical)  
Maximum Target Rotation Angle  
30  
400 mm  
16"  
16"  
12"  
8"  
400 mm  
300 mm  
200 mm  
100 mm  
0
300 mm  
200 mm  
100 mm  
0
12"  
8"  
20  
25 mm Rod  
100 x 100 mm  
10  
0
4"  
4"  
0
0
10 mm Rod  
100 mm  
200 mm  
300 mm  
400 mm  
4"  
100 mm  
200 mm  
300 mm  
400 mm  
4"  
10  
20  
30  
8"  
8"  
12"  
16"  
3000 mm  
(120")  
12"  
16"  
3000 mm  
(120")  
0
600 mm  
(24")  
1200 mm  
(48")  
1800 mm  
(72")  
2400 mm  
(96")  
0
500 mm  
(20")  
1000 mm  
(40")  
1500 mm  
(60")  
2000 mm  
(80")  
2500 mm  
(100")  
3000 mm  
(120")  
0
600 mm  
(24")  
1200 mm  
(48")  
1800 mm  
(72")  
2400 mm  
(96")  
DISTANCE  
DISTANCE  
DISTANCE  
Accessories  
Brackets  
BWA-BK-004  
BWA-BK-006  
Mounts both the K50U  
81  
64  
Mounts both the K50U  
Ultrasonic sensor and a  
Wireless Q45U Node or  
DX80 Node  
4X Ø6  
Ø33.5  
Ultrasonic sensor and a  
Wireless Q45U Node  
97  
181  
4X Ø5.2  
Ø30  
54  
54  
Euro-Style Cordsets - Double Ended  
When using the FlexPower Node with integrated battery, use a double ended cordset. When using a FlexPower Node with external  
power supply, use a single ended cordset. If using the communication lines, the cable length cannot exceed 3 meters (10 ft).  
P/N 191599 Rev. F  
www.bannerengineering.com - Tel: +1-763-544-3164  
5
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
5-Pin Threaded M12/Euro-Style Cordsets—Double Ended and Less Than 3 m Long  
Model  
Length  
Style  
Dimensions  
Pinout  
Male  
DEE2R-51D  
DEE2R-53D  
0.31 m (1 ft)  
0.91 m (3 ft)  
1
40 Typ.  
2
4
5
3
M12 x 1  
ø 14.5  
Female  
Female Straight/  
Male Straight  
2
44 Typ.  
1
4
DEE2R-58D  
2.44 m (8 ft)  
3
5
M12 x 1  
ø 14.5  
1 = Brown  
2 = White  
3 = Blue  
4 = Black  
5 = Green/Yellow  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or  
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not  
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO  
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES  
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,  
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously  
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the  
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will  
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at  
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:  
www.bannerengineering.com.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

DEE2R-8100D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-815D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-81D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-825D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-83D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-850D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-875D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE2R-88D

SSA-EB Series Lighted Emergency Stop Push Button
BANNER

DEE9P-0L2-A191-K87-146

D Subminiature Connector, 9 Contact(s), Male, Solder Terminal, #4-40, Plug,
ITT

DEE9P-0L2-K87-146

D Subminiature Connectors
ITT

DEE9P-OL2-A191-K87-146

D Subminiature Connector, 9 Contact(s), Male, Solder Terminal, Plug,
ITT

DEE9P-OL2-K87-146

D Subminiature Connector, 9 Contact(s), Male, Solder Terminal, Plug,