K30ANPBGXDQ [BANNER]

EZ-LIGHT® K30 Series Pick-to-Light Sensors;
K30ANPBGXDQ
型号: K30ANPBGXDQ
厂家: Banner Engineering    Banner Engineering
描述:

EZ-LIGHT® K30 Series Pick-to-Light Sensors

文件: 总4页 (文件大小:219K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
EZ-LIGHT K30 Series Pick-to-Light  
Sensors  
Datasheet  
Compact, Single-Point Devices for Error Proofing of Bin-Picking Operations  
Rugged, cost-effective and easy-to-install multicolor indicator light with pushbutton  
Illuminated dome provides an easy-to-see green job light; some models also light  
red for alternate operation  
Waterproof IP65 construction for washdown environments  
Compact devices are self-contained — no controller needed  
Immune to EMI and RFI interference  
12 V dc to 30 V dc operation  
Cabled and quick disconnect models available  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to  
serious injury or death. This device does not include the self-checking redundant circuitry necessary  
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an  
energized or de-energized sensor output condition.  
Models  
1
Model  
Function  
Output  
PNP, NO  
NPN, NO  
Connection  
Job Light  
K30APPBGXDQ  
K30ANPBGXDQ  
K30APPBGRCQ  
Job light is ON at all times while job input is active.  
Pressing push button activates output.  
Green  
Job light is green while job input is active, until push PNP, NO  
button is pushed.  
Pressing push button activates output and overrides  
job light (it turns Red) for visual verification that  
action was sensed.  
Green (Red)  
Green (Red)  
Integral 4-pin M12/  
Euro-style quick  
disconnect  
K30ANPBGRCQ  
K30APPBGREQ  
K30ANPBGREQ  
NPN, NO  
PNP, NO  
NPN, NO  
Job light is ON at all times while job input is active.  
Pressing push button activates output.  
Pressing push button while job input is inactive  
causes unit to light Red, providing visual indication  
that sensor is functioning properly.  
Overview  
The solid-state output interfaces to a system controller, which is pre-programmed for a specific sequence of tasks.  
Mounted in or near each bin in an assembler’s work station, the sensor job light signals the assembler:  
Which bins contain items to be picked in a given operation; and  
In what order they should be picked.  
As the assembler takes a part in sequence and pushes the button, the sensor senses that the part was removed and sends  
an output signal to the controller. The controller verifies if the correct part was taken and may respond by turning that job  
light OFF, activating the job light of the next bin in the sequence.  
If multiple parts are to be removed from one bin, the job light may remain ON until the appropriate number of signals is  
returned to the controller. If an incorrect part is selected, the control system may be wired to signal an alarm for the  
assembler and/or a supervisor, or it may be programmed to interpret the action as a call for parts.  
1
Integral quick disconnect models are listed.  
To order the 2 m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K30APPBGXD.  
Models with a quick disconnect require a mating cordset.  
Original Document  
155796 Rev. D  
22 November 2016  
155796  
®
EZ-LIGHT K30 Series Pick-to-Light Sensors  
Installation  
Install the K30 sensor at such a height and in a location that will be easy for the user and/or supervisor to see the  
indicator and comfortable for the user to press the push-button.  
Wiring  
1 = brown  
2 = white  
3 = blue  
4 = black  
1
+
12-30V dc  
3
4
2
Load  
Job Light  
Enable 8V dc  
Specifications  
Supply Voltage and Current  
Job Light Enable  
12 V dc to 30 V dc (10% max. ripple) at 50 mA maximum  
Input Impedance: 10 KOhms  
Input high > 8.0 V  
Supply/Output Protection Circuitry  
Protected against reverse polarity and transient voltages  
Environmental Rating  
IEC IP65  
Output Rating  
Enclosure Type 13  
Max. load: 150 mA  
ON-state saturation voltage: < 0.5 V at 10 mA dc; < 1.0 V at 150 mA  
Construction  
dc  
Base: polycarbonate  
OFF-state leakage current: < 10 μA at 30 V dc  
Translucent dome: polycarbonate  
Push button: thermoplastic  
Output Protection  
Required Overcurrent Protection  
Protected against false pulse on power-up and continuous overload or  
short circuit of output.  
WARNING: Electrical connections must be  
made by qualified personnel in accordance  
with local and national electrical codes and  
regulations.  
Output Response Time  
1 millisecond On and Off  
Indicators  
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Overcurrent protection may be provided with external fusing or via  
Current Limiting, Class 2 Power Supply.  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to www.bannerengineering.com.  
Job ("Pick") Indicator: Green  
Pick Sensed Indicator: Red or OFF, depending on model  
Connections  
Integral 4-pin M12/Euro-style quick disconnect fitting, PVC-jacketed 2  
m (6.5 ft) or 9 m (30 ft) cable, depending on model.  
Operating Conditions  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
40 °C to +50 °C (40 °F to +122 °F)  
90% at +50 °C maximum relative humidity (non-condensing)  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
Storage Temperature  
40 °C to +70 °C (40 °F to +158 °F)  
Certifications  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 155796 Rev. D  
®
EZ-LIGHT K30 Series Pick-to-Light Sensors  
Dimensions  
All measurements are listed in millimeters [inches], unless noted otherwise.  
Accessories  
Cordsets  
4-Pin Threaded M12/Euro-Style Cordsets  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
MQDC-406  
MQDC-415  
MQDC-430  
1.83 m (6 ft)  
4.57 m (15 ft)  
9.14 m (30 ft)  
44 Typ.  
Straight  
M12 x 1  
MQDC-450  
15.2 m (50 ft)  
2
3
ø 14.5  
1
4
MQDC-406RA  
MQDC-415RA  
MQDC-430RA  
1.83 m (6 ft)  
4.57 m (15 ft)  
9.14 m (30 ft)  
32 Typ.  
[1.26"]  
1 = Brown  
2 = White  
3 = Blue  
30 Typ.  
[1.18"]  
Right-Angle  
4 = Black  
MQDC-450RA  
15.2 m (50 ft)  
M12 x 1  
ø 14.5 [0.57"]  
Brackets  
SMB22A  
32  
Right-angle bracket with curved slot  
for versatile orientation  
C
41  
12-ga. stainless steel  
Mounting hole for 22 mm sensor  
B
A
46  
Hole center spacing: A to B = 26.0  
Hole size: A = ø 4.6, B = 4.6 x 16.9, C = 22.2  
P/N 155796 Rev. D  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
®
EZ-LIGHT K30 Series Pick-to-Light Sensors  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.  
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty  
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,  
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE  
OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE  
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,  
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER  
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product  
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection  
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval  
by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product  
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most  
recent version of any documentation, refer to: www.bannerengineering.com.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

K30ANT2FGRCQP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light
BANNER

K30ANT2FGREQP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light
BANNER

K30ANT2FGRF2QP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Series Illuminated Multipurpose Buttons
BANNER

K30ANT2FGXDQP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light
BANNER

K30ANT2FRGF2QP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Series Illuminated Multipurpose Buttons
BANNER

K30ANT2FXGF2QP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Series Illuminated Multipurpose Buttons
BANNER

K30ANT2FXRF2QP

EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Series Illuminated Multipurpose Buttons
BANNER

K30ANTGRCQ

EZ- LIGHT® Touch K30 Series Pick-to-Light
BANNER

K30ANTGREQ

EZ- LIGHT® Touch K30 Series Pick-to-Light
BANNER

K30ANTGRF2Q

EZ-LIGHT® Touch K30 Series Illuminated Multipurpose Buttons
BANNER

K30ANTGXDQ

EZ- LIGHT® Touch K30 Series Pick-to-Light
BANNER

K30ANTRGF2Q

EZ-LIGHT® Touch K30 Series Illuminated Multipurpose Buttons
BANNER