LMBWLB72HK [BANNER]

WLB72B Industrial LED Light Bar (AC);
LMBWLB72HK
型号: LMBWLB72HK
厂家: Banner Engineering    Banner Engineering
描述:

WLB72B Industrial LED Light Bar (AC)

文件: 总6页 (文件大小:634K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
WLB72B Industrial LED Light Bar (AC)  
Datasheet  
Banner's WLB72 is a very bright LED luminaire that features an even light output for a no glare 'glow'. The WLB72 series is  
designed for a wide variety of environments and applications, including but not limited to work stations, machine lighting, and low  
bay lighting. The WLB72 uses advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting  
solution.  
Increase worker productivity and ergonomics with bright, high-quality, uniform light  
Exceptionally energy efficient for overall cost savings  
Durable light with a metal housing and shatter-resistant window  
Intensity can be controlled from 5% to 100% using a compatible dimmer  
Rated for use at 120 V ac to 277 V ac  
Fast installation with multiple integrated mounting options or accessory brackets  
The WLB72 Industrial LED Light Bars are continuous run models that come with 1/2-inch conduit knockouts on the side, back, and  
both end caps that allow for lights to be cascaded or "daisy-chained" for a continuous length of light. WLB72 models come with a  
five year, limited warranty. To view or download the latest technical information about this product, including specifications,  
dimensions, accessories, and wiring, see www.bannerengineering.com.  
Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde  
www.bannerengineering.com toda la documentación técnica de los WLB72B Industrial LED Light Bar,  
disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las  
instrucciones de instalación de estos dispositivos.  
Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation  
technique complète des WLB72B Industrial LED Light Bar sur notre site www.bannerengineering.com pour les  
détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage.  
Models  
Lighted  
Family  
Tier  
Voltage Cascadable  
Length (mm)  
Control  
Connector  
LED Color  
Window  
WLB72  
B
Z
C
W
1200  
D
A
CT  
1200  
C = Cascadable  
A = 0-10 V Analog  
Dimming  
B = Basic  
Z = AC  
W = Daylight white  
D = Diffused window  
CT = Conduit Entry  
Original Document  
210184 Rev. A  
22 August 2019  
210184  
WLB72B Industrial LED Light Bar (AC)  
Installation Instructions  
Install the Light  
To remove cover, press  
inward at points shown  
on both sides.  
4x  
Self-tapping screw holes (4x)  
Figure 1. Removing the cover  
WARNING:  
Risk of Electric Shock  
Failure to follow these instructions could result in serious injury or death.  
Installation and service of luminaries should be performed by a qualified licensed electrician.  
Disconnect or turn off power before installing, removing, or servicing luminaire. Luminaire must be  
installed and connected in accordance with the National Electrical Code (NEC) and any applicable local  
code requirements. Luminaire must be supplied with a 120–277 V ac 50/60 Hz fuse box or circuit  
breaker.  
To mount the WLB72 Industrial LED Light Bar, follow these steps.  
1. Remove luminaire from packaging and inspect for damage before installing.  
2. Determine the mounting method and location. The WLB72 is rated for wall, ceiling, or under cabinet mounting. Optional  
mounting brackets are available, see Accessories (p. 5).  
3. Remove the cover from the housing by pressing inward at the two snap features on the housing.  
4. Place the light in the mounting location and mark the positions of the light mounting holes.  
5. Drill the holes and use the appropriate screws to secure the luminaire to the mounting location.  
Wire the Light  
Follow these steps to wire your WLB72 Industrial LED Light Bar.  
Three-position connector  
Two-position connector  
First position to LED Driver  
Middle position supply  
Last position for cascade to  
another light  
white black  
(N) (L)  
ground  
Cable to LED board  
(board not shown)  
Black and red wires are DC  
output power to LED board.  
Installer must make connection  
using two-position connector, as  
shown.  
INPUT  
OUTPUT  
LED Driver  
Two dimming wires  
(purple and gray)  
1. Remove the cover from the housing by pressing inward at the two snap locations on the housing.  
2
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 210184 Rev. A  
WLB72B Industrial LED Light Bar (AC)  
2. Connect the power by removing the selected knockout and installing either 1/2-inch conduit or an AC power cord with  
supplied cord grip strain relief. If you are using rigid conduit, the conduit hub/connector must be approved for use in dry or  
damp locations and must be connected to the conduit before the hub/connector is connected to the luminaire. The  
supplied cord grip diameter range is 4.3 to 11.4 mm.  
3. Connect the incoming supply wires to the LED Driver input connectors according to the wiring diagram.  
4. Connect the ground wire to the three-position ground connector.  
5. If you are using 0–10 V analog dimming, connect to the LED Driver dimming connectors according to the wiring diagram.  
6. Attach the red and black wires from the cover LED board to the output connectors on the Driver.  
7. Re-attach the cover to the housing by snapping it into place. Secure the cover to the housing by using a minimum of one  
self tapping screw on each end of the housing (four screws are provided).  
8. Repeat these steps on other end of the luminaire if you are connecting to more than one luminaire in a continuous run.  
Wiring Diagram  
Diagram  
Wire  
Connection  
L - Black  
N - White  
Line/Hot  
Neutral  
L
L
N
N
Earth ground  
- Green/Yellow  
Dim (+) - Purple  
0–10 V dc analog dimming  
Dim (+)  
Dim (-)  
Dim (+)  
Dim (-)  
Dim (-) - Gray  
Return analog dimming  
Specifications  
Supply Voltage  
Construction  
Nominal voltage: 120 V ac to 277 V ac, 60 Hz in North America  
Nominal voltage: 120 V ac to 277 V ac, 50/60 Hz outside North America  
Power factor: > 0.95 at 120 V ac and > 0.90 at 277 V ac  
Total harmonic distortion (THD): < 20%  
Galvanized steel with corrosion resistant polyester powder coat,  
polycarbonate window and end caps.  
Weight: 2.8 kg (6.25 lbs)  
Mounting  
See electrical characteristics on product label  
Compatible with a variety of common mounting and hanging methods.  
Housing includes six mounting holes for surface mounting.  
Several optional mounting brackets are available (see Accessories)  
Supply Current  
Max.  
Current  
Typical Current Draw (A)  
Connections  
Lighted  
Length  
(mm)  
1/2-inch trade size conduit knockout in nine locations  
Draw (A) at  
90 V ac  
120 V ac  
0.43  
230 V ac  
0.22  
277 V ac  
0.18  
Weight  
2.8 kg (6.2 lbs)  
1200  
0.850  
Environmental Rating  
IEC IP20  
Supply Protection Circuitry  
Operating Temperature  
Protected against transient voltages  
Surface Mount Installation: –40 °C to +50 °C (–40 °F to +122 °F)  
85% at +50 °C maximum relative humidity (non-condensing)  
LED Lifetime  
When operating within specifications, output will decrease less than 30%  
after 50,000 hours.  
Light Characteristics  
Storage Temperature  
Daylight White Efficacy: 130 lumens/watt typical at 120 V ac at 25 °C (77 °F)  
CRI: 82, typical  
–40 °C to +70 °C (–40 °F to +158 °F)  
Vibration and Mechanical Shock  
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC  
60068-2-6 (5 minute sweep, 30 minute dwell)  
Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27  
Impact: IK07 (IEC 60068-2-75)  
Color  
Color Temperature (CCT)  
5000 K ( 300 K)  
Lumens (Typical at 25 °C)  
6800  
Daylight White  
P/N 210184 Rev. A  
www.bannerengineering.com - Tel: + 1 888 373 6767  
3
WLB72B Industrial LED Light Bar (AC)  
Dimming  
Compatible with 0–10 V analog LED dimming, dimmable to 5% intensity  
Shielded wiring required for dimming control.  
Required Overcurrent Protection  
WARNING: Electrical connections must be  
made by qualified personnel in accordance with  
local and national electrical codes and  
regulations.  
Application Notes  
When connecting continuous run/cascadable lights in series, it is important  
not to exceed maximum current limitations of 14 AWG, 75 °C wire, in  
accordance with the National Electrical Code (NEC) and any applicable local  
code requirements.  
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Two or more lights installed in parallel must maintain a 150 mm (6 inch)  
spacing to maintain a 50 °C operating temperature.  
Overcurrent protection may be provided with external fusing or via Current  
Limiting, Class 2 Power Supply.  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to www.bannerengineering.com.  
Certifications and Approvals  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
UL/cULus E470122  
Performance Curves  
Illuminance at a Distance  
Isolux Pattern  
Polar Candela Distribution  
2
1
1
2
0 m  
2
1
180°  
170°  
160°  
2000  
1667  
1333  
1000  
667  
Center Beam (lux)  
7935 lux  
1984 lux  
882 lux  
Beam Width (m)  
1.4 m 2.1 m  
2.8 m 4.3 m  
4.2 m 6.4 m  
5.6 m 8.6 m  
6.9 m 10.7 m  
8.3 m 12.8 m  
150°  
140°  
130°  
0.5 m  
1.0 m  
1.5 m  
2.0 m  
120°  
110°  
100°  
496 lux  
333  
317 lux  
0
90°  
80°  
0 m  
2.5 m  
3.0 m  
333  
220 lux  
667  
70°  
60°  
50°  
40°  
Vert.  
Horiz.  
1000  
1333  
1667  
2000  
Vertical Spread: 108.5°  
Horizontal Spread: 129.9°  
1
2
30°  
20°  
10°  
0°  
Vertical Angle:  
0° Vertical 90° Horizontal  
Mount height of 3 meters (3 m)  
200 lux  
175 lux  
150 lux  
125 lux  
100 lux  
75 lux  
50 lux  
25 lux  
Illuminance at a Distance  
Dimensions  
All measurements are listed in millimeters, unless noted otherwise.  
81.6  
[3.21]  
72.0  
[2.83]  
1221.7  
[48.10]  
9X Ø 22.23  
[0.88]  
KNOCKOUT  
Bracket Mounting Holes  
(SMBWLB72F)  
951.7  
[37.47]  
6X Ø 6.35 Hanging Bracket  
[0.25]  
Mounting Holes  
45.0  
[1.77]  
1021.7  
[40.22]  
4X M5 x 0.8  
PEM  
NUT  
4
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 210184 Rev. A  
WLB72B Industrial LED Light Bar (AC)  
Accessories  
Brackets  
All measurements are listed in millimeters, unless noted otherwise.  
LMBWLB72F  
LMBWLB72HK  
TILT RANGE 60º  
25.4  
Stainless steel  
Hanging bracket kit allows for suspended  
150  
LOOSEN  
TO ADJUST  
OR TO TILT  
LIGHT  
60º  
4 x Ø7  
installation  
Includes two surface mount brackets and  
four screws for mounting onto the  
housing  
124.6  
9.7  
Includes two hanging bracket assemblies  
Cables allow for 60 degrees of angle  
adjustment  
40  
LMBWLB72RAS  
Swivel brackets allow for 180° of  
79  
70  
movement in seven fixed positions  
Stainless steel  
Includes two swivel bracket assemblies  
and eight screws  
2 x Ø7  
60  
25  
Installing and Adjusting the WLB72 Hanging Bracket  
To install the hanging bracket, assemble the bracket components as shown.  
1. Hanging cable (2)  
2. Gripper  
2a. Plunger  
1
2b. Cross cable nut  
3. Cross cable (2)  
4. Bracket (2)  
LOOSEN  
TO ADJUST  
OR TO TILT  
LIGHT  
A
B
2a  
2
2b  
3
4
When feeding the cable through the gripper, allow at least one inch of cable beyond the gripper. Do not feed any excess cable into  
the light housing. To adjust the gripper position:  
1. Lift all weight off the gripper.  
2. Press the plunger to release the cable.  
3. Slide the gripper to a new position.  
4. Release the plunger.  
5. Tighten the cross cable nut manually.  
P/N 210184 Rev. A  
www.bannerengineering.com - Tel: + 1 888 373 6767  
5
WLB72B Industrial LED Light Bar (AC)  
Other Accessories  
EBATTWLB72 Emergency LED Driver (Battery) Kit  
When AC power fails, the emergency driver will provide 90 minutes of emergency light. When the AC power  
is restored, the emergency driver automatically returns to the charge mode.  
The kit includes everything needed to install battery inside the WLB72 housing  
Smart charger for low energy consumption  
Class 2 output, UL 1310 certified, CSA 22.2 No. 223-91 compliant  
Meets CEC Title 20 (California Energy Commission) standards  
Maintenance free Nickel-Cadmium battery, 7 to 10 year life expectancy  
Includes illuminated battery test switch  
ACC-WLB72-CSR-5 Cord Grip Accessory (5 pack with nuts)  
One strain relief is included with each WLB72 light  
Cable diameter: 4.3 mm to 11.4 mm (0.17 in to 0.45 in)  
For use in clearance holes 22.2 mm (0.875 in) or threaded holes ½ NPT  
Nylon 6/6 construction with TPE sealing gland resists common solvents  
IEC IP68 rated (70 psi, 5 Bar)  
Flammability Rating 94V-2  
Temperature: –40 °C to 115 °C (–40 °F to 239 °F)  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for five years on daylight white and warm white models and one year on all other  
models following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is  
found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner  
product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO  
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES  
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,  
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously  
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the  
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will  
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at  
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:  
www.bannerengineering.com.  
For patent information, see www.bannerengineering.com/patents.  
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)  
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:  
1.  
2.  
This device may not cause harmful interference, and  
This device must accept any interference received, including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are  
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the manufacturer.  
Mexican Importer  
Banner Engineering de Mèxico, S. de R.L. de C.V.  
David Alfaro Siqueiros 103 Piso 2 Valle oriente  
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269  
81 8363.2714  
©
Banner Engineering Corp. All rights reserved  

相关型号:

LMBWLB72RAS

WLB72B Industrial LED Light Bar (AC)
BANNER

LMBZ10VALT1G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ10VALT1G/T3G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ12VALT1G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ12VALT1G/T3G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ15VALT1G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ15VALT1G/T3G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ18VALT1G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ18VALT1G/T3G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ20VALT1G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ20VALT1G/T3G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC

LMBZ27VALT1G

24 and 40 Watt Peak Power Zener Transient Voltage Suppressors
LRC