WORLD-BEAM Q12 Series Sensor  
Datasheet  
Miniature self-contained photoelectric sensors in universal housing  
Bright, visible red (640 nm) light source  
Standard models available with 4-wire 2 m (6.5 ft) or 9 m (30 ft) cable or 3 or 4-  
wire 150 mm (6 in) pigtail with Pico-style M8 threaded connector  
Solid-state, bipolar outputs: one current sourcing (PNP) and one current  
sinking (NPN) standard on 4-wire models  
Single output solid-state PNP or NPN standard on Q3 models  
Light Operate (L.O.) or Dark Operate (D.O.), depending on model  
Models available with PFA chemical-resistant jacket (1200 psi washdown  
rated) for use in harsh environments  
Compact 8 mm (0.31 in) housing mounts almost anywhere  
Crosstalk avoidance circuitry for applications with multiple sensors  
LED status indicators for Power ON, Output Overload, Signal Received, and  
Marginal Signal  
Models with black housing are available  
Standard Model  
Chemical-Resistant  
Model  
WARNING:  
Do not use this device for personnel protection  
Using this device for personnel protection could result in serious injury or death.  
This device does not include the self-checking redundant circuitry necessary to allow its use in  
personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-  
energized (off) output condition.  
Chemical-Resistant Models  
1 2  
Model  
Sensing Mode  
Range  
Output  
640 nm Visible Red  
Q126ECR  
N/A  
Q12AB6RCR  
Bipolar LO  
1.5 m (4.9 ft)  
Q12RB6RCR  
Bipolar DO  
OPPOSED  
Effective Beam: 5.7 mm (0.22 in)  
Performance based on use of 90% reflectance white test card.  
Q12AB6FF15CR  
Q12RB6FF15CR  
13 mm (0.5 in) cutoff;  
Bipolar LO  
Bipolar DO  
8 mm (0.3 in)  
focus  
Q12AB6FF30CR  
Q12RB6FF30CR  
Q12AB6FF50CR  
Q12RB6FF50CR  
Bipolar LO  
Bipolar DO  
Bipolar LO  
Bipolar DO  
28 mm (1.1 in) cutoff;  
14 mm (0.6 in) focus  
FIXED-FIELD  
VISIBLE RED  
640 nm Visible Red  
48 mm (1.9 in) cutoff;  
14 mm (0.6 in) focus  
1
2
Only standard 2 m (6.5 ft) cables are available for chemical-resistant models.  
To order the black housing model, add the prefix D to the model number, for example, DQ12AB6FF15CR.  
Original Document  
119223 Rev. K  
31 July 2019  
119223  
®
WORLD-BEAM Q12 Series Sensor  
Standard Models  
3
Sensing Mode  
Model  
Range  
Connection  
Output  
640 nm Visible Red  
Q126E (emitter)  
Q12AB6R  
2 m (6.5 ft) cable  
2 m (6.5 ft) cable  
N/A  
Bipolar LO  
Bipolar DO  
1 PNP LO  
1 PNP DO  
1 NPN LO  
1 NPN DO  
Bipolar LO  
Bipolar DO  
1 PNP LO  
1 PNP DO  
1 NPN LO  
1 NPN DO  
Bipolar LO  
Bipolar DO  
1 PNP LO  
1 PNP DO  
1 NPN LO  
1 NPN DO  
Q12RB6R  
2 m  
(6.5 ft)  
Q12AP6RQ3  
Q12RP6RQ3  
Q12AN6RQ3  
Q12RN6RQ3  
Q12AB6LP  
150 mm (6 in) cable with a 3-pin  
M8/Pico-style QD  
OPPOSED  
Effective Beam: 5.7 mm (0.22 in)  
2 m (6.5 ft) cable  
Q12RB6LP  
P
Q12AP6LPQ3  
Q12RP6LPQ3  
Q12AN6LPQ3  
Q12RN6LPQ3  
Q12AB6LV  
4
1 m (40 in)  
150 mm (6 in) cable with a 3-pin  
M8/Pico-style QD  
POLAR RETRO  
640 nm Visible Red  
2 m (6.5 ft) cable  
Q12RB6LV  
Q12AP6LVQ3  
Q12RP6LVQ3  
Q12AN6LVQ3  
Q12RN6LVQ3  
1.5 m  
(59 in)  
4
150 mm (6 in) cable with a 3-pin  
M8/Pico-style QD  
RETRO  
640 nm Visible Red  
Performance based on use of 90% reflectance white test card.  
Q12AB6FF15  
Q12RB6FF15  
Bipolar LO  
Bipolar DO  
1 PNP LO  
1 PNP DO  
1 NPN LO  
1 NPN DO  
Bipolar LO  
Bipolar DO  
1 PNP LO  
1 PNP DO  
1 NPN LO  
1 NPN DO  
Bipolar LO  
Bipolar DO  
1 PNP LO  
1 PNP DO  
1 NPN LO  
1 NPN DO  
2 m (6.5 ft) cable  
15 mm (0.6 in)  
Q12AP6FF15Q3  
Q12RP6FF15Q3  
Q12AN6FF15Q3  
Q12RN6FF15Q3  
Q12AB6FF30  
cutoff;  
10 mm (0.4 in)  
focus  
150 mm (6 in) cable with a 3-pin  
M8/Pico-style QD  
2 m (6.5 ft) cable  
Q12RB6FF30  
30 mm (1.2 in)  
cutoff;  
16 mm (0.63 in) focus  
Q12AP6FF30Q3  
Q12RP6FF30Q3  
Q12AN6FF30Q3  
Q12RN6FF30Q3  
Q12AB6FF50  
FIXED-FIELD  
VISIBLE RED  
150 mm (6 in) cable with a 3-pin  
M8/Pico-style QD  
640 nm Visible Red  
2 m (6.5 ft) cable  
Q12RB6FF50  
Q12AP6FF50Q3  
Q12RP6FF50Q3  
Q12AN6FF50Q3  
Q12RN6FF50Q3  
50 mm (2 in)  
cutoff; 16 mm (0.63 in) focus  
150 mm (6 in) cable with a 3-pin  
M8/Pico-style QD  
3
To order the black housing model, add the prefix D to the model number, for example DQ12AB6FF15.  
To order the 9 m (30 ft) cable model, add the suffix W/30 to the model number. For example, Q126E W/30.  
To order the 150 mm (6 in) cable with a 4-pin M8/Pico-style (M8 threaded) QD model, add the suffix Q to the model number. For example,  
Q126EQ.  
To order the 150 mm (6 in) cable with a 4-pin M12/Euro-style QD model, add the suffix Q5 to the model number. For example Q126EQ5.  
4
Retroreflective range is specified using one model BRT-60X40C retroreflector. Actual sensing range may be more or less than specified, depending upon  
efficiency and reflective area of the retroreflector(s) used.  
2
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 119223 Rev. K  
®
WORLD-BEAM Q12 Series Sensor  
Indicator Features  
1 - Amber and green LEDs  
1
Green on: power to sensor is on  
Green flashing: output is overloaded  
Amber on: received signal  
Amber flashing: marginal signal  
Chemical-Resistant models: LEDs are visible through translucent PFA jacket. Rated to  
1200 psi washdown.  
Wiring  
Cabled wiring diagrams are shown. Connections for QD models are functionally identical. (Emitters have no connection to black  
and white.)  
CAUTION: Observe proper ESD precautions (grounding) when connecting QD models.  
Emitters  
Bipolar Models  
PNP Models  
Key  
1 = Brown  
2 = White  
3 = Blue  
1
+
1
3
+
10-30V dc  
3
3
2
4 = Black  
10-30 V dc  
10-30V dc  
+
Load  
Load  
4
1
Load  
4
NPN Models  
3-pin M8/Pico-style Male QD  
4-pin M8/Pico-style Male QD  
4-pin M12/Euro-style Male QD  
1
4
2
1
4
3
4
3
1
2
3
10-30 V dc  
+
3
1
4
Load  
Specifications  
Supply Voltage and Current  
Output Configuration  
10 to 30 V dc (10% maximum ripple) at 20 mA maximum current  
Bipolar (1 NPN and 1 PNP) solid-state output or Single output (PNP or  
NPN), LO or DO, depending on model  
Sensing Beam  
640 nm visible red  
Repeatability  
175 microseconds  
Supply Protection Circuitry  
Protected against reverse polarity and transient voltages  
Switching Frequency  
Opposed Mode: 385 Hz  
All Other Modes: 715 Hz  
P/N 119223 Rev. K  
www.bannerengineering.com - Tel: + 1 888 373 6767  
3
®
WORLD-BEAM Q12 Series Sensor  
Output Protection Circuitry  
Output Ratings  
Protected against false pulse on power-up, short-circuit protected  
OFF-state leakage current:  
NPN: 200 µA  
PNP: 10 µA  
ON-state saturation voltage:  
Output Response Time  
Opposed Mode: 1.3 ms ON; 900 µs OFF  
All Other Modes: 700 µs ON/OFF  
NOTE: 120 ms delay on power-up; outputs do not conduct during this time.  
NPN: 1.25 V at 50 mA  
PNP: 1.45 V at 50 mA  
Indicators  
One Yellow and one Green LED (see Figure 1)  
Vibration and Mechanical Shock  
All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz  
maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum  
acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms  
duration, half sine wave) requirements.  
Construction  
Polarized Retro Models: Thermoplastic elastomer housing with glass lens  
All Other Standard Models: Thermoplastic elastomer housing with  
polycarbonate lens  
Chemical-Resistant Models: Housing encased in PFA jacket; cable encased  
in 3/16 in O.D. PFA tubing  
Connections  
Required Overcurrent Protection  
Standard Models: 2 m (6.5 ft) or 9 m (30 ft) attached PVC cable, or 150 mm  
(6 in) pigtail with M8 or M12 threaded connection, depending on the model  
WARNING: Electrical connections must be  
made by qualified personnel in accordance with  
local and national electrical codes and  
regulations.  
ordered  
Chemical-Resistant Models: 2 m (6.5 ft) cable encased in 3/16 in O.D. PFA  
tubing  
Environmental Rating  
Standard Models: IEC IP67  
Chemical-Resistant Models: IEC IP67 (NEMA6) and PW12 1200 psi  
washdown per NEMA ICS5, Annex F-2002  
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Overcurrent protection may be provided with external fusing or via Current  
Limiting, Class 2 Power Supply.  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to www.bannerengineering.com.  
Conditions  
Operating Temperature: –20 °C to +55 °C (–4 °F to +131°F)  
Storage Temperature: –30 °C to +75 °C (–22 °F to +167 °F)  
95% at +50 °C maximum relative humidity (non-condensing)  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
Certifications  
(Chemical-resistant models are  
not UR/UL approved.)  
Dimensions  
12.4 mm  
(0.49")  
M3 mounting  
screws included  
8.0 mm  
(0.31")  
Polarized Retro  
Models  
15.0 mm  
(0.59")  
4.7 mm  
(0.19")  
5.1 mm  
(0.20")  
Emitter (opposed mode models)  
Emitter (all other models)  
23.1 mm  
(0.91")  
22 mm  
(0.86")  
3.4 mm  
(0.13")  
3.5 mm  
(0.14")  
Ø 3 mm (0.12")  
max. torque  
0.9 Nm (8 in-lbf)  
Figure 1. Standard Models  
4
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 119223 Rev. K  
®
WORLD-BEAM Q12 Series Sensor  
22.6 mm  
(0.89")  
8.1 mm (0.32")  
12.5 mm (0.49")  
Mounting hardware  
not included  
5.9 mm (0.23")  
* When mounting by running a screw through  
both flanges without support between the flanges,  
the max. torque applied should be 0.1 Nm (1 in-lbf).  
6.2 mm  
(0.25")  
3.2 mm (0.13")  
Ø 3.4 mm (0.13")  
max. torque*  
0.9 Nm (8 in-lbf)  
Emitter (opposed mode models)  
28.8 mm (1.13")  
15.0 mm (0.59")  
10.7 mm (0.42")  
4.7 mm  
(0.18")  
8.6 mm (0.34")  
5.5 mm (0.22")  
Emitter (all other models)  
4.8 mm (0.19") O.D.  
PFA Tube  
2 m (6.5')  
Ø12.5 mm (0.49")  
Figure 2. Chemical-Resistant Models  
Performance Curves - Opposed Mode  
Excess Gain  
Beam Pattern  
1000  
Q12..  
Opposed Mode  
Q12..  
Opposed Mode  
3 mm  
0.12"  
2 mm  
1 mm  
0
0.08"  
0.04"  
0
100  
Chemical-Resistant  
Standard  
1 mm  
2 mm  
3 mm  
0.04"  
0.08"  
0.12"  
10  
Standard  
Chemical-Resistant  
1
0
0.5 m  
20"  
1 m  
40"  
1.5 m  
60"  
2 m  
80"  
2.5 m  
100"  
0.01 m  
0.033'  
0.1 m  
0.33'  
1 m  
3.3'  
10 m  
33'  
DISTANCE  
DISTANCE  
Performance Curves - Retroreflective Mode  
Performance is based on the use of a model BRT-60X40C retroreflector.  
Polarized Retroreflective  
Retroreflective  
Excess Gain  
Beam Pattern  
Excess Gain  
Beam Pattern  
1000  
100  
10  
1000  
100  
10  
Q12..  
Polarized Retro  
Q12..  
Retroreflective  
Q12..  
Polarized Retro  
Q12..  
Retroreflective  
9 mm  
0.3"  
30 mm  
1.2"  
6 mm  
3 mm  
0
0.2"  
0.1"  
0
20 mm  
10 mm  
0
0.8"  
0.4"  
0
3 mm  
6 mm  
9 mm  
0.1"  
0.2"  
0.3"  
10 mm  
20 mm  
30 mm  
0.4"  
0.8"  
1.2"  
0
0
0.3 m  
12"  
0.6 m 0.9 m  
24"  
0.3 m  
12"  
0.6 m 0.9 m  
24" 35"  
1.5 m  
59"  
1.2 m  
47"  
1.2 m 1.5 m  
47" 59"  
1
1
35"  
DISTANCE  
0.01 m  
0.03'  
0.1 m  
0.33'  
1 m  
3.3'  
10 m  
33'  
0.01 m  
0.03'  
0.1 m  
0.33'  
1 m  
3.3'  
10 m  
33'  
DISTANCE  
DISTANCE  
DISTANCE  
P/N 119223 Rev. K  
www.bannerengineering.com - Tel: + 1 888 373 6767  
5
®
WORLD-BEAM Q12 Series Sensor  
Performance Curves - Fixed-Field  
Focus and spot sizes are typical. Performance based on use of 90% reflectance white test card.*  
Fixed Field -- 15 mm  
Fixed Field -- 30 mm  
Fixed Field -- 50 mm  
1000  
100  
10  
1000  
1000  
Q12..FF50  
Q12..FF30  
Fixed-Field  
Q12..FF15  
Fixed-Field  
Fixed-Field Mode  
100  
10  
100  
10  
Standard  
Standard  
Standard  
Chemical-Resistant  
Chemical-Resistant  
Chemical-Resistant  
1
1
1 mm  
0.04"  
10 mm  
0.4"  
100 mm  
4.0"  
1000 mm  
40.0"  
1
1 mm  
0.04"  
10 mm  
0.4"  
100 mm  
4.0"  
1000 mm  
40.0"  
1 mm  
0.04"  
10 mm  
0.4"  
100 mm  
4.0"  
1000 mm  
40.0"  
DISTANCE  
DISTANCE  
DISTANCE  
Standard Models:  
Standard Models:  
Standard Models:  
Ø 0.4 mm spot size at 10 mm focus  
Ø 1.5 mm spot size at 15 mm cutoff  
Ø 0.5 mm spot size at 16 mm focus  
Ø 3.0 mm spot size at 30 mm cutoff  
Ø 0.5 mm spot size at 16 mm focus  
Ø 6.5 mm spot size at 50 mm cutoff  
Chemical-Resistant Models:  
Chemical-Resistant Models:  
* Using 18% gray test card: cutoff distance will be  
80% of value shown.  
Using 6% black test card: cutoff distance will be  
60% of value shown.  
Ø 0.4 mm spot size at 8 mm focus  
Ø 1.5 mm spot size at 13 mm cutoff  
Ø 0.5 mm spot size at 14 mm focus  
Ø 3.0 mm spot size at 28 mm cutoff  
* Using 18% gray test card: cutoff distance will be  
95% of value shown.  
Using 6% black test card: cutoff distance will be  
90% of value shown.  
Chemical-Resistant Models:  
* Using 18% gray test card: cutoff distance will be  
90% of value shown. Using 6% black test card:  
cutoff distance will be 80% of value shown.  
Ø 0.5 mm spot size at 14 mm focus  
Ø 6.5 mm spot size at 48 mm cutoff  
* Using 18% gray test card: cutoff distance will be  
70% of value shown. Using 6% black test card:  
cutoff distance will be 50% of value shown.  
Accessories  
Cordsets  
3-Pin Threaded M8/Pico-Style Cordsets  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
PKG3M-2  
PKG3M-5  
PKG3M-7  
PKG3M-9  
PKG3M-10  
PKW3M-2  
PKW3M-5  
2 m (6.56 ft)  
5 m (16.40 ft)  
7 m (22.97 ft)  
9 m (29.53 ft)  
10 m (32.81 ft)  
2 m (6.56 ft)  
35 Typ.  
Straight  
ø 9.5  
M8 x 1  
4
1
3
28 Typ.  
5 m (16.40 ft)  
1 = Brown  
3 = Blue  
4 = Black  
20 Typ.  
Right-Angle  
PKW3M-9  
9 m (29.53 ft)  
M8 x 1  
ø 9.5  
6
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 119223 Rev. K  
®
WORLD-BEAM Q12 Series Sensor  
4-Pin Threaded M8/Pico-Style Cordsets—Single Ended  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
PKG4M-2  
PKG4M-5  
2 m (6.56 ft)  
5 m (16.4 ft)  
35 Typ.  
Straight  
ø 9.5  
PKG4M-9  
9 m (29.5 ft)  
M8 x 1  
4
3
2
1
PKW4M-2  
PKW4M-5  
2 m (6.56 ft)  
5 m (16.4 ft)  
28 Typ.  
1 = Brown  
2 = White  
3 = Blue  
20 Typ.  
Right Angle  
4 = Black  
PKW4M-9  
9 m (29.5 ft)  
M8 x 1  
ø 9.5  
4-Pin Threaded M12/Euro-Style Cordsets—Single Ended  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
MQDC-406  
MQDC-415  
MQDC-430  
1.83 m (6 ft)  
4.57 m (15 ft)  
9.14 m (30 ft)  
44 Typ.  
Straight  
M12 x 1  
ø 14.5  
2
3
MQDC-450  
15.2 m (50 ft)  
1
4
MQDC-406RA  
MQDC-415RA  
MQDC-430RA  
1.83 m (6 ft)  
4.57 m (15 ft)  
9.14 m (30 ft)  
32 Typ.  
[1.26"]  
1 = Brown  
2 = White  
3 = Blue  
30 Typ.  
[1.18"]  
Right-Angle  
4 = Black  
MQDC-450RA  
15.2 m (50 ft)  
M12 x 1  
ø 14.5 [0.57"]  
Brackets  
4 X  
Ø3.3  
SMBQ12T  
SMBQ12A  
Ø3.3  
Right-angle bracket  
20-ga. 300 series stainless  
steel  
Adjustable right-angle  
bracket  
20-ga. 300 series stainless  
steel  
2 X  
Ø3.2  
34  
34  
Ø3.2  
34  
34  
11  
11  
Hole center spacing: A to B = 7.6  
Hole size: A = 3.5 x 8.1, B=ø 3.2  
Hole center spacing: A to B = 7.6  
Hole size: A = 3.5 x 8.1, B=ø 3.2  
Apertures  
Opposed-mode Q12 sensors (standard models only) may be fitted with apertures to narrow or shape the sensor’s effective beam  
to more closely match the size or profile of the objects being sensed. A common example is the use of “line” (or “slot”) type  
apertures to sense thread.  
Note: The use of apertures will reduce the sensing range (see table below).  
P/N 119223 Rev. K  
www.bannerengineering.com - Tel: + 1 888 373 6767  
7
®
WORLD-BEAM Q12 Series Sensor  
Reduced Sensor Range  
(Two Apertures Used)  
Model  
Description  
Pieces  
Circular  
APQ12-.5  
APQ12-1  
APQ12-1.5  
APQ12-2  
0.5 mm (0.02 in) diameter  
1 mm (0.04 in) diameter  
1.5 mm (0.06 in) diameter  
2 mm (0.08 in) diameter  
10  
10  
10  
10  
60 mm (2.4 in)  
190 mm (7.5 in)  
400 mm (15.7 in)  
725 mm (28.5 in)  
Horizontal Slot  
APQ12-.5H  
APQ12-1H  
0.5 mm (0.02 in)  
1 mm (0.04 in)  
10  
10  
350 mm (13.8 in)  
725 mm (28.5 in)  
Vertical Slot  
APQ12-.5V  
APQ12-1V  
0.5 mm (0.02 in)  
1 mm (0.04 in)  
10  
10  
450 mm (17.7 in)  
900 mm (35.4 in)  
Protective Jacket  
APQ12-4S  
APKQ12  
4 mm (0.16 in) square  
10  
18  
2000 mm (78.7 in)  
Kit containing two of each aperture  
above  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or  
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not  
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO  
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES  
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,  
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously  
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the  
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will  
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at  
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:  
www.bannerengineering.com.  
For patent information, see www.bannerengineering.com/patents.  
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)  
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:  
1.  
2.  
This device may not cause harmful interference, and  
This device must accept any interference received, including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are  
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the manufacturer.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

PKG4M-9

Miniature self-contained photoelectric sensors in universal housing
BANNER

PKGS-00GXP1-R

Sensor/Transducer,
MURATA
MURATA

PKGS-00LDP1-R

Analog Circuit,
MURATA
MURATA
MURATA
MURATA

PKGS-25NBP1-R

operating temperature range
MURATA
MURATA
MURATA
MURATA