QT50R-EU-AFS [BANNER]
R-GAGE® QT50R-AFS Sensor;型号: | QT50R-EU-AFS |
厂家: | Banner Engineering |
描述: | R-GAGE® QT50R-AFS Sensor |
文件: | 总7页 (文件大小:570K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
R-GAGE QT50R-AFS Sensor
Datasheet
Radar-Based Sensors for Detection of Moving and Stationary Targets
•
•
•
•
FMCW (true-presence) radar detects moving and stationary objects
Higher sensitivity and shorter range
Adjustable sensing field — ignores objects beyond setpoint
Easy setup and configuration of range, sensitivity, and output with simple
DIP switches
•
•
•
Sensing functions are unaffected by wind, falling rain or snow, fog, humidity,
air temperatures, or light
Sensor operates in Industrial, Scientific, and Medical (ISM)
telecommunication band
Rugged IP67 housing withstands harsh environments
Protected by US patents
CAUTION: Make No Modifications to this Product
Any modifications to this product not expressly approved by Banner Engineering could void the user's
authority to operate the product. Contact Banner Engineering for more information.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Models
Maximum
Range
Supply
Voltage
1
2
Models
Connection
Telecom Approval
Output
Bipolar NPN/PNP
Telecom approved for Europe, UK,
Australia, New Zealand, China, and Japan
5-wire 2 m
(6.5 ft)
Integral cable
QT50R-EU-AFS
QT50R-KR-AFS
12 to 30V dc
12 to 24 V dc
3.75 m
(12.3 ft)
DIP-switch-selectable N.O.
or N.C.
Telecom approved for South Korea
1
Cabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect fitting, add suffix "Q" to the model number (for example,
QT50R-xx-AFSQ). QD models require a mating cordset; see Quick Disconnect (QD) Cordsets on page 6.
For additional countries, contact Banner Engineering.
2
Original Document
169603 Rev. E
17 August 2016
169603
®
R-GAGE QT50R-AFS Sensor
Overview
The R-GAGE sensor emits a well-defined beam of high-frequency radio
waves from an internal antenna. Some of this emitted energy is
reflected back to the receiving antenna. Signal processing electronics
determine the distance from the sensor to the object based on the
time delay of the return signal. The sensor can be configured (via DIP
switches) to sense objects up to a specific distance, ignoring objects
beyond this distance (also called background suppression).
Setpoint
Figure 2. R-GAGE features
1. Power LED: Green (power ON)
2. Signal Strength LED: Red (flashes in
proportion to the signal strength)
X
Y
D
3. Output LEDs: Yellow (output energized);
Red (configuration)
Figure 1. R-GAGE setpoint
Access the DIP switches behind the threaded cap
on the sensor back (not shown)
R-GAGE setpoint distances, minimum and maximum (sensor will detect objects up to setpoint and ignore objects beyond
the setpoint)
Description
Distance
X
Y
Minimum setpoint distance
Maximum setpoint distance
Dead Zone3
2 m (6.6 ft)
3.75 m (12.3 ft)
D
Sensor Configuration
The sensing zone distance, sensitivity, and output configuration can be selected via the DIP switches on the back of the
sensor. Use the included spanner to open the screw-off cover on the back of the sensor and access the DIP switches.
Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight
seal.
DIP Switch Functions
Switch
1, 2, 3
4, 5
Function
Sensing distance (detects objects from sensor face to this point)
Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern)
Normally open/normally closed output functionality
Response Speed
6
7, 8
DIP switch 1 is on the left and DIP switch 8 is on the right.
3
Typical dead zone: 0.4 m (1.3 ft) for moving and 1.0 m (3.3 ft) for stationary targets, but varies with target reflectivity
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 169603 Rev. E
®
R-GAGE QT50R-AFS Sensor
Distance Settings
Switch 1
Switch 2
Switch 3
Distance
0
0
0
0
0
1
2 m (6.6 ft)
2.25 m (7.4 ft)
2.5 m (8.2 ft)
2.75 m (9.0 ft)
3 m (9.8 ft)
0
1
0
0
1
1
1 *
1
0 *
0
0 *
1
3.25 m (10.7 ft)
3.5 m (11.5 ft)
3.75 m (12.3 ft)
1
1
0
1
1
1
* Default settings
Sensitivity Selection
Switch 4
Switch 5
Sensitivity
4 (Highest)
3 (High)
0*
0
0*
1
1
0
2 (Medium)
1 (Low)
1
1
* Default settings
NOTE: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and
not to narrow the beam width. Narrow-beam R-GAGE sensor models are available.
Output Configuration
* Default settings
Switch 6
NO/NC
NO
0*
1
NC
Response Speed
Switch 7
Switch 8
On (ms)
30
Off (ms)
Total (ms)
100
0
0*
1
0
1*
0
70
50
300
350
30
1000
6000
1030
1
1
120
6120
* Default settings
P/N 169603 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
3
®
R-GAGE QT50R-AFS Sensor
Specifications
Range
Indicators
Power LED: Green (power ON)
The sensor is able to detect a proper object (see Detectable Objects)
from 1 to 3.75 m (3.3 to 12.3 ft), depending on target
Signal Strength LED: Red, flashes in proportion to signal strength.
Steady on at 4x excess gain. Only indicates signal amplitude, not
target distance.
Output LEDs: Yellow (output energized) / Red (configuration)
See Overview on page 2
Supply Voltage
12 to 30 V dc, less than 100 mA, exclusive of load
For KR models: 12 to 24 V dc, less than 100 mA exclusive of load
Detectable Objects
Adjustments
Objects containing metal, water, or similar high-dielectric materials
DIP-switch-configurable sensing distance, sensitivity, response time,
and output configuration
Operating Principle
Frequency modulated continuous-wave (FMCW) radar
Construction
Operating Frequency
Housing: ABS/polycarbonate
Lightpipes: Acrylic
EU, KR Models: 24.050–24.250 GHz, ISM Band
Access Cap: Polyester
Maximum Output Power
ERP: 3.3 mW, 5 dBm
Connections
EIRP: 100 mW, 20 dBm
Integral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD fitting. QD
models require a mating cordset
Supply Protection Circuitry
Operating Temperature
Protected against reverse polarity and transient overvoltages
−40 °C to +65 °C (−40 °F to +149 °F)
Delay at Power-up
Environmental Rating
Less than 2 seconds
IEC IP67
Output Configuration
Certifications
Bipolar NPN/PNP output, 150mA; DIP switch 6 selects N.O. (default) or
N.C. operation
ETSI/EN 300 440
CMIIT Category G
ARIB STD T-73
KC mark - MSIP/RRA
for others, contact Banner Engineering.
Country of Origin: USA
Output Protection
Protected against short circuit conditions
Response Time
DIP switches 7 & 8 select ON/OFF response time
SRD24-IO3B24100.2TR0.1 South Korea Class A Certification
A
(
)
(A
)
,
.
Dimensions
74.1 mm
(2.92")
46.1 mm
(1.82")
37.0 mm
(1.46")
4X Ø4.4 mm
(Ø 0.17")
38.1 mm
(1.50")
33.0 mm
(1.30")
50.8 mm
(2.00")
66.0 mm
(2.60")
19.7 mm
(0.78")
R45.0 mm
(R1.77")
37.0 mm
(1.46")
34.2 mm
(1.35")
M30 X 1.5
ISO-6g
50.8 mm
(2.00")
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 169603 Rev. E
®
R-GAGE QT50R-AFS Sensor
Beam Pattern
Typical Beam Pattern (with BRTR-CC20E Radar
Target, Radar Cross Section = 50 m2)
Typical Beam Pattern (with 4 different targets) at
highest sensitivity level
Left-Right Beam Pattern
Left-Right Beam Pattern
4 m
4 m
4
4
1
2 m
2 m
1
0
-2 m
-4 m
0
-2 m
-4 m
0
2 m
4 m
6 m
8 m
0
2 m
4 m
6 m
8 m
Distance
Distance
1–4: Indicates sensitivity level
1: Weak Object (Radar cross section = 0.25 m2)
2: Car (Radar cross section = 3 m2)
3: Large Truck (Radar cross section = 50 m2)
4: Passenger Train (Radar cross section = 300 m2)
NOTE: The effective beam pattern depends on the sensitivity level and target properties.
Windows
The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the
distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20%
signal reduction when the sensor is placed behind a window.
Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials.
Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and
distance from the sensor to the window.
Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance
between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums,
and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window
materials which can be used at any distance without issue.
Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood
directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the
face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of
the window can be detected as a dielectric boundary.
P/N 169603 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
5
®
R-GAGE QT50R-AFS Sensor
Wiring
Wiring Key:
1 = Brown
1
3
2
4
+
12-30V dc
–
2 = White
Load 1
Load 2
3 = Blue
5
4 = Black
shield (QD cordset)
5 = Gray (Do not connect)
NOTE: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc
common. Shielded cordsets are recommended for all QD models.
Accessories
Quick Disconnect (QD) Cordsets
5-Pin Threaded M12/Euro-Style Cordsets—with Shield
Model
Length
Style
Dimensions
Pinout (Female)
MQDEC2-506
MQDEC2-515
MQDEC2-530
1.83 m (6 ft)
4.57 m (15 ft)
9.14 m (30 ft)
44 Typ.
Straight
2
M12 x 1
1
4
MQDEC2-550
15.2 m (50 ft)
ø 14.5
3
MQDEC2-506RA
MQDEC2-515RA
MQDEC2-530RA
1.83 m (6 ft)
4.57 m (15 ft)
9.14 m (30 ft)
5
32 Typ.
[1.26"]
1 = Brown
2 = White
3 = Blue
30 Typ.
[1.18"]
4 = Black
5 = Gray
Right-Angle
MQDEC2-550RA
15.2 m (50 ft)
M12 x 1
ø 14.5 [0.57"]
NOTE: Pin 5 is not used.
Mounting Brackets
All measurements are in mm
SMB30SC
67
SMB30MM
•
•
•
Swivel bracket with 30 mm
mounting hole for sensor
Black reinforced
•
12-ga. stainless steel bracket
with curved mounting slots
for versatile orientation
Clearance for M6 (¼ in)
hardware
57
70
B
58
C
thermoplastic polyester
•
•
57
B
Stainless steel mounting and
swivel locking hardware
included
Mounting hole for 30 mm
sensor
A
29
A
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 169603 Rev. E
®
R-GAGE QT50R-AFS Sensor
Weather Deflector
QT50RCK
•
•
Required if the R-GAGE is exposed to rain or snow
Prevents buildup of water or ice from interfering with sensor
performance
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE
OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval
by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product
specifications or update documentation at any time. For the most recent version of any documentation, refer to: www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明