R55FVBQ [BANNER]
R55F Series Fiber-Optic Color Mark Sensors;型号: | R55FVBQ |
厂家: | Banner Engineering |
描述: | R55F Series Fiber-Optic Color Mark Sensors |
文件: | 总12页 (文件大小:333K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
R55F Series Fiber-Optic Color Mark Sensors
For Plastic and Glass Fiber Optics
R55F Series Sensor Features
•
•
Outstanding color contrast sensitivity; detects 16 levels of gray scale.
Depending on beam color, reliably detects the toughest color mark contrasts,
including 20% yellow against white.
•
•
Fast, 50-microsecond response.
Choose from infrared or one of four visible beam colors: red, blue, green and
white.
•
•
Fibers mount in small and otherwise inaccessible areas.
Easy push-button programming options include Static TEACH, Static Single-Point
TEACH, Dynamic TEACH and Remote TEACH; plus manual sensitivity adjustment.
•
•
Non-volatile memory.
Glass fiber models function well in harsh environments typically associated with
printing processes.
•
Plastic fiber models function well in applications that require repeated flexing of
the fibers.
•
•
•
•
Fibers install quickly without tools.
Bipolar (NPN/PNP) outputs with three Delay settings (0, 20 or 40 milliseconds).
Choice of integral cable or QD connector models.
Mounts flat or to 35 mm DIN rail; two brackets included with sensor (one for
angle mount, one for flat mount).
R55F Series Sensor Overview
The R55F Fiber-Optic Sensor was developed to provide simplicity of operation and
access to tight areas for color mark (registration) sensing applications. The R55F is a
technological advancement from earlier R55 models.
R55F sensors feature TEACH mode sensitivity adjustment, by presenting the light and
the dark sensing conditions to the sensor. In addition, sensitivity may be fine-tuned at
any time by simply clicking the “+” or “-” buttons on the sensor. The ten-element signal
strength light bar clearly displays the relative received signal strength.
The bipolar (one NPN and one PNP) outputs may be programmed to include a 20 or
40-millisecond pulse stretcher (OFF Delay), if required. Both TEACH mode sensitivity
adjustment and output SETUP are accomplished using the push-buttons on the sensor,
or by supplying input pulses via the Remote Teach input.
TEACH mode has two options: Static TEACH and Dynamic TEACH. Static TEACH is
used to manually set the two sensing conditions individually or to program a specific
condition to be sensed (single-point TEACH). Dynamic TEACH provides a means for
teaching a series of conditions on-the-fly; the R55F “averages” the sensing events and
automatically sets (and periodically updates via the adaptive threshold feature) the
switch point between light and dark conditions.
Printed in USA
05/01
P/N 57945 rev. B
R55F Series Fiber-Optic Color Mark Sensors
Visible Red, 650 nm
Visible Green, 525 nm
Visible Blue, 475 nm
Visible White, 450-650 nm
Infrared, 880 nm
Advantages of glass fiber optics for color mark sensing:
• Randomly mixed bifurcated fiber bundles produce the best optics for color mark sensing.
• Bundle of small fibers may be shaped at sensing end tip to match the color mark shape.
• Best chemical resistance.
R55F Series Glass Fiber-Optic Sensor Models
Model
Number
Supply
Voltage
Output
Type
Maximum Sensing Distance
For black-to-white contrast
Cable*
Visible Red, 650 nm
R55FV
0.060" dia. Bundle: 28 mm (1.1")
0.125" dia. Bundle: 110 mm (4.3")
5-wire 2 m (6.5') cable
5-pin Euro-style QD
R55FVQ
Visible Green, 525 nm
R55FVG
0.060" dia. Bundle: 12 mm (0.5")
0.125" dia. Bundle: 50 mm (2.0")
5-wire 2 m (6.5') cable
5-pin Euro-style QD
R55FVGQ
Visible Blue, 475 nm
R55FVB
Bipolar
NPN/PNP
0.060" dia. Bundle: 12 mm (0.5")
0.125" dia. Bundle: 50 mm (2.0")
5-wire 2 m (6.5') cable
5-pin Euro-style QD
10 to 30V dc
R55FVBQ
Visible White, 450 - 650 nm
0.060" dia. Bundle: 12 mm (0.5")
R55FVW
R55FVWQ
Infrared, 880 nm
R55F
5-wire 2 m (6.5') cable
5-pin Euro-style QD
0.125" dia. Bundle: 50 mm (2.0")
0.060" dia. Bundle: 40 mm (1.6")
0.125" dia. Bundle: 140 mm (5.5")
5-wire 2 m (6.5') cable
5-pin Euro-style QD
R55FQ
Advantages of plastic fiber optics for color mark sensing:
• Plastic fibers may be repeatedly flexed.
• Low cost.
Visible Red, 650 nm
Visible Green, 525 nm
Visible Blue, 475 nm
• Most models may be cut to fit in the field.
Visible White, 450-650 nm
R55F Series Plastic Fiber-Optic Sensor Models
Model
Number
Supply
Voltage
Output
Type
Maximum Sensing Distance
For black-to-white contrast
Cable*
Visible Red, 650 nm
R55FP
5-wire 2 m (6.5') cable
5-pin Euro-style QD
0.040" dia. Fibers: 60 mm (2.4")
0.040" dia. Fibers: 28 mm (1.1")
0.040" dia. Fibers: 28 mm (1.1")
R55FPQ
Visible Green, 525 nm
R55FPG
5-wire 2 m (6.5') cable
5-pin Euro-style QD
R55FPGQ
Bipolar
NPN/PNP
10 to 30V dc
Visible Blue, 475 nm
R55FPB
5-wire 2 m (6.5') cable
5-pin Euro-style QD
R55FPBQ
Visible White, 450 - 650 nm
R55FPW
5-wire 2 m (6.5') cable
5-pin Euro-style QD
0.040" dia. Fibers: 28 mm (1.1")
R55FPWQ
* 9m (30') cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., R55FV W/30). A model with a QD
connector requires a mating cable (see page 11).
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 2
R55F Series Fiber-Optic Color Mark Sensors
Glass Fiber Installation Procedure:
Plastic fibers
shown; procedure
is identical for
glass fibers
1) Check to see that a rubber o-ring is pre-installed on each fiber control end.
2) Slide the fiber clip to the open position (A).
B
3) Insert one fiber end into each port (B). Push firmly on the fiber ends to compress
the o-rings and align the grooves in the fiber ends with the slot in the fiber clip.
Fiber
Clip
4) Slide the fiber clip back into place, locking the fibers into position (C).
C
A
Plastic Fiber Installation Procedure:
NOTE: R55F sensors accept 0.75, 1.0, and 1.5 mm (0.03", 0.04", and 0.06") core
diameter plastic fibers.
1) Cut the “control ends” (sensor ends) of the plastic fiber(s) to the desired length
per the procedure which accompanies the fiber assembly.
2) If not already done, separate bifurcated fibers by approximately 2" from the control
ends.
Figure 1. Installing fibers into the R55F
Series sensor
3) Slide the fiber clip to the open position (A).
4) Insert the fiber ends into each port and push them in as far as they will go (B).
5) Slide the fiber clip back into place, locking the fibers into position (C).
Fiber Optic Mounting Considerations
Mount the sensing end of the fiber optic assembly so that the light image is totally
contained within the boundaries of the color mark to be sensed. The light image is
made smaller by moving the sensing tip closer to the surface of the material to be
sensed.
When sensing marks on shiny (specular) materials, such as metal, plastic or glossy
paper, mount the sensing tip of the fiber at approximately 15° from perpendicular to
the material surface to minimize strong direct reflections.
Isolate the fiber mounting from vibration. Also, maintain mechanical stability of the
surface to be sensed (e.g., stabilize web flutter at the sensing point).
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 3
R55F Series Fiber-Optic Color Mark Sensors
Using the R55F Series Sensor
RUN Mode
Dynamic
TEACH (+)
Push Button
Output
Conducting
LED
Delay
Configuration
Indicator LED
10-Segment
Light Bar
Normal operation of the R55F is called RUN mode. The LED indicators (see
Figure 2) operate as follows in RUN mode:
Switch
Point
LO
(Light Operate)
LED*
Output Conducting LED: ON when outputs are active
Static
TEACH (-)
Push Button
Delay Configuration Indicator LED: OFF No OFF Delay is programmed
DO
(Dark Operate)
LED*
ON 20 or 40-ms OFF Delay is programmed
Light Operate LED: ON to indicate Light Operate configuration
* Either LO or DO LED is ON
whenever sensor has power
and is in RUN mode
Dark Operate LED: ON to indicate Dark Operate configuration
(NOTE: Since either one of these is always ON when the sensor is operating, the
combined Light/Dark Operate LEDs also provide a functional Power-ON indication.)
Figure 2. R55F Series sensor features
10-Segment Light Bar: indicates signal strength, with respect to the sensing
threshold (“Switch Point”).
TEACH Modes
The sensitivity of the R55F may be quickly optimized by using one of two available TEACH modes: Static TEACH or Dynamic
TEACH. Either may be performed using the push buttons on the sensor, or remotely, using a remote switch or process controller
connected to the sensor’s gray wire (see page 8). Either a sensing window or a specific point may be taught.
Static TEACH
In Static TEACH mode, the sensor learns the light condition and the dark condition, each one time. Sensitivity is automatically set
to place the switch point midway between the two conditions. In addition, the condition taught first becomes the output ON
condition.
Sensitivity may be adjusted at any time when the sensor is in RUN mode by clicking the “+” and “-” buttons. Each click translates
to 1/2 segment on the signal strength light bar. For best sensing reliability, the light and dark conditions should register equally
distant from the switch point on the signal strength light bar.
Single-Point TEACH
The R55F sensor also may be taught a single specific target, using an alternate Static TEACH procedure. The sensor will sense
only the mark taught and will ignore signals both stronger and weaker. The sensitivity to the taught mark then may be adjusted up
or down.
To perform single-point TEACH, place the target in front of the sensor. Press and hold the “Static” button until the LO and DO
LEDs begin to flash, then double-click the Static button. If the single point was successfully taught, the two center sections of the
bar graph will flash.
Manually adjust the sensitivity by clicking either the “+” or “-” button; the bar graph will flash two segments centered about the
sensing point. If the sensitivity is increased (-), the two lighted segments will become closer together, and farther apart if the
sensitivity is decreased (+). If the segments do not flash while the sensitivity is being adjusted, the setting has reached its
maximum and cannot be adjusted further.
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 4
R55F Series Fiber-Optic Color Mark Sensors
Static TEACH Procedure - Push Button
See page 8 for Remote
TEACH procedures
Push Button
Resulting Indicator Status
LO and DO: Alternately flash green
Press and Hold ≥ 2 seconds
Press and hold STATIC button
until LO and DO indicators
alternately flash, then release
button.
: ON amber (indicating ready to
teach output ON condition)
SETUP
Switch Point
Light Bar: Goes OFF
TEACH Condition #1
(Output ON state)
LO and DO: Alternately flash Green
Single-click
: OFF (indicating ready to teach
output OFF condition)
SETUP
Present the output ON sensing
condition and single-click
STATIC button.
Switch Point
Light Bar: Remains OFF
Contrast accepted: one of the ten
segments flashes for three seconds to
indicate relative contrast, and then the
sensor enters RUN mode.
TEACH Condition #2
(Output OFF state)
Single-click
SETUP
Present the output OFF
sensing condition and single-
click STATIC button.
Switch Point
Contrast too low: every other segment
flashes for three seconds to indicate low
contrast, and the sensor returns to TEACH
Condition #1.
Signal Strength
Light Bar
NOTES:
1) The sensor will return to RUN mode if either TEACH condition is not registered within 90 seconds. Also,
TEACH mode may be cancelled by pressing and holding the push button for ≥ 2 seconds. In either case, the
sensor will revert to the previous conditions taught (i.e., exit without save).
2) If the sensing conditions are accepted at the end of TEACH Condition #2, the signal strength light bar flashes
one of its ten segments for three seconds to indicate relative sensing contrast. The higher the flashing
segment, the higher the measured sensing contrast. High contrast relates directly to sensing reliability. High-
contrast sensing applications are most tolerant of sensing variables, such as web flutter or variations in color
mark color or print density.
Static Single-Point TEACH Procedure - Push Button
Push Button
Resulting Indicator Status
LO and DO: Alternately flash green
Press and Hold ≥ 2 seconds
Press and hold STATIC button
until LO and DO indicators
alternately flash, then release
button.
: ON amber (indicating ready to
teach output ON condition)
SETUP
Switch Point
Light Bar: Goes OFF
LO or DO: depending on condition of
TEACH Condition to be
Sensed (Output ON state)
taught
Double-click
SETUP
: OFF
Present the output ON sensing
condition and double-click
STATIC button.
Switch Point
Light Bar: Two center segments are lit
if TEACH was successful.
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 5
R55F Series Fiber-Optic Color Mark Sensors
Dynamic TEACH
Dynamic TEACH is used to program sensitivity during actual machine run conditions. During
Dynamic TEACH, the R55F samples many color marks against their background material and
automatically sets the sensitivity at the optimum level. Dynamic TEACH activates the sensor’s
adaptive threshold system, which continuously tracks minimum and maximum signal levels, and
automatically maintains centering of the switch point between the light and dark conditions. The
adaptive threshold system remains in effect during RUN mode to automatically adjust for changes
in the light or the dark conditions.
When Dynamic TEACH mode is used to program sensitivity, the output ON state must be assigned
to either the light or dark condition using the SETUP mode (see page 7).
Sensitivity may be adjusted at any time when the sensor is in RUN mode by clicking the “+” and “-”
buttons. However, when a manual adjustment is made, the adaptive threshold system is disabled
(cancelled).
Dynamic TEACH Procedure - Push button
See page 8 for Remote
TEACH procedures
Push Button
Resulting Indicator Status
LO and DO: Alternately flash green
: OFF
Press and Hold ≥ 2 seconds
Press and hold DYNAMIC
button until LO and DO
indicators alternately flash.
SETUP
Switch Point
Light Bar: Goes OFF
Continue to Depress
While Sensor Samples
Light and Dark Conditions
LO and DO: Alternately flash green
: OFF
Continue depressing the
DYNAMIC button while
sampling light and dark
sensing conditions.
SETUP
Light Bar: Remains OFF
Switch Point
Contrast accepted: one of the ten
segments flashes for three seconds to
indicate relative contrast, and the sensor
enters RUN mode.
Release
Release the DYNAMIC button
when finished sampling light
and dark sensing conditions.
SETUP
Contrast too low: five light bar segments
flash for three seconds to indicate low
contrast, and sensor reverts to the
previously taught conditions.
Switch Point
NOTES:
1) If the sensing conditions are accepted at the end of Dynamic TEACH, the signal strength light bar flashes one
of its ten segments for three seconds to indicate relative sensing contrast. The higher the flashing segment,
the higher the measured sensing contrast. High contrast relates directly to sensing reliability. High contrast
sensing applications are most tolerant of sensing variables, such as web flutter or variations in color mark
color or print density.
2) If the sensor does not measure enough contrast at the end of Dynamic TEACH, every other segment of the
signal strength light bar flashes in unison for three seconds to warn of unacceptably low contrast, and the
sensor returns to RUN mode with its previously taught conditions.
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 6
R55F Series Fiber-Optic Color Mark Sensors
SETUP Mode
SETUP mode is used to configure sensor output response for:
- Light or Dark operate
+
DYNAMIC
- 20- or 40-millisecond pulse stretcher (OFF delay), if required.
OFF
Delay
Press and Hold
Both Push Buttons
LO
It will be necessary to access SETUP mode only if the settings which result from
TEACH mode programming are not the settings required for the application. The
status LEDs indicate the output response configuration when the sensor is in RUN
mode, as follows:
DO
STATIC
–
- LO indicator ON = output is light operate
- DO indicator ON = output is dark operate
- OFF Delay indicator ON = either 20- or 40-millisecond delay is programmed
- OFF Delay indicator OFF = no output delay is programmed
Figure 3. SETUP mode
To change the output response settings;
1) Press and hold BOTH push buttons until the signal strength light bar turns OFF.
2) Click EITHER push button to toggle through the six possible settings
indicated as follows:
Delay
Indicator
LO
Indicator
DO
Indicator
Output Configuration
Light operate with no delay
OFF
Flashing
ON
ON
ON
OFF
OFF
OFF
ON
Light operate with 20 ms delay
Light operate with 40 ms delay
Dark operate with no delay
ON
OFF
OFF
OFF
OFF
Dark operate with 20 ms delay
Dark operate with 40 ms delay
Flashing
ON
ON
ON
3) Press and hold both push buttons until the signal strength light bar turns ON,
indicating return to RUN mode.
NOTE: If SETUP mode programming is interrupted and remains inactive for 30
seconds, the sensor returns to RUN mode with the most recent settings
(i.e., exit and save current selection).
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 7
R55F Series Fiber-Optic Color Mark Sensors
Remote Programming
The gray wire of the R55F may be connected to a remote switch or to a process
controller to:
0.04 < T < 0.8 sec
Switch Open
- Set sensitivity via either Static or Dynamic TEACH mode
- Set output response via SETUP mode
- Disable the push button functions
Switch Closed
to dc common
A remote programming switch is connected between the gray wire and dc common (see
Hookup diagrams on page 11). The switch may be either a normally-open contact, or an
open-collector NPN transistor with its emitter connected to dc common.
Figure 4. Input pulse timing
Remote programming is accomplished using a specified sequence of input pulses.
The duration of each pulse is defined as:
0.04 seconds < T < 0.8 seconds (40 ms < T< 800 ms)
Remote Static TEACH Mode
Present
Output ON
Condition
Present
Output OFF
Condition
1) Present the Output ON condition to the fiber sensing end and pulse the Remote
TEACH input once.
T
T
2) Wait at least 0.8 seconds, present the Output OFF condition, and pulse the Remote
TEACH input once.
> 0.8 sec
If sensing contrast is adequate, the sensor flashes one segment of the signal strength
light bar for 3 seconds to indicate relative contrast, and then enters RUN mode.
Figure 5. Static TEACH mode
If contrast is too low, the sensor flashes five segments of the signal strength light bar
in unison to warn of unacceptably low contrast, and returns to re-teach the Output ON
condition (Step 1).
Present
Output ON
Condition
Double-Click
T
Remote Static Single-Point TEACH
The single-point TEACH may also be performed using the remote wire. Present the
target and single-click the remote wire. Wait for at least 0.8 second, then double-click
the remote wire. If the TEACH is successful, the sensor will flash the middle two LEDs
of the bar graph, and return to RUN mode.
T
T
T
> 0.8 sec
Figure 6. Static Single-Point TEACH mode
Remote Dynamic TEACH Mode
1) Hold the TEACH input low for > 2 seconds
TEACH Light
and Dark
2) Continue holding the TEACH input low while presenting light and dark sensing
conditions. Open switch when finished teaching.
> 2 sec
Conditions
If sensing contrast is adequate, the sensor flashes one segment of the signal strength
light bar for 3 seconds to indicate relative contrast, and then enters RUN mode.
If contrast is too low, the sensor flashes five segments of the signal strength light bar
in unison to warn of unacceptably low contrast, and returns to RUN mode with its
previously taught conditions.
Figure 7. Dynamic TEACH mode
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 8
R55F Series Fiber-Optic Color Mark Sensors
T
etc.
Remote SETUP Mode
T
T
T
T
T
1) To enter SETUP mode, pulse once, wait 0.04 to 0.8 seconds, then pulse again.
> 0.8 sec
> 0.8 sec
> 0.8 sec
2) Wait > 0.8 seconds, then enter sequential pulses to toggle between the six
output configuration choices (see page 7). Spacing between sequential pulses
must be > 0.8 seconds.
Two pulses
to Enter
SETUP
Sequential
pulses to toggle
between configuration choices
Figure 8. SETUP mode
3) To exit SETUP mode, hold the TEACH input low for > 2 seconds.
T
T
T
Locking Out (Disabling) the Push Buttons
T
T
T
T
Pulse four times to enable
or disable push button
Pulse four times to disable (or to re-enable) the push buttons.
Figure 9. Push button lockout
R55F Series Sensor Dimensions
Plastic Fiber
10.0 mm
(0.39")
12.9 mm
(0.51")
Glass Fiber
10.0 mm
(0.39")
30.0 mm
(1.18")
12.9 mm
(0.51")
Quick-Disconnect
Models
Cabled
Models
25.0 mm
(0.99")
24.5 mm
(0.97")
+
+
DYNAMIC
DYNAMIC
85.4 mm
(3.36")
OFF
Delay
OFF
Delay
35.0 mm
(1.40")
U
SETUP
LO
DO
LO
DO
STATIC
STATIC
–
–
4.5 mm
(0.18")
11.6 mm
(0.46")
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 9
R55F Series Fiber-Optic Color Mark Sensors
R55F Series Sensor Specifications
Supply Input
10 to 30V dc (10% maximum ripple) at less than 70 mA, exclusive of load
Protected against reverse polarity and transient voltages
Bipolar (NPN and PNP)
Supply Protection Circuitry
Output Configuration
150 mA max each output @ 25°C (derate ≈ 1 mA per °C increase)
OFF-state leakage current: < 5 µA @ 30V dc
ON-state saturation voltage: PNP Output < 1V @ 10 mA and 1.5V @ 150 mA
NPN Output < 200 mV @ 10 mA and 1V @ 150 mA
Output Rating
Output Protection
Output Response
Protected against false pulse on power-up and continuous overload or short-circuit of outputs.
50 microseconds
NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time.
Using push buttons (“+” Dynamic and “-” Static):
Manually adjust Switch Point using “+” or “-” buttons
Dynamic TEACH (teach on-the-fly) sensitivity adjustment
Static TEACH sensitivity adjustment
Light operate/Dark operate
OFF Delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds
Adjustments
(see pages 4 - 9)
Using Remote TEACH input (gray wire):
Dynamic TEACH (teach on-the-fly) sensitivity adjustment
Static TEACH sensitivity adjustment
Light operate/Dark operate
OFF Delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds
Push button lockout for security
10-segment (green) light bar indicates signal strength
Light Operate (green)
Dark Operate (green)
Indicator LEDs
Construction
Outputs Conducting (yellow)
OFF Delay (green): SETUP Mode: OFF — no delay
Flashing — 20 ms delay
RUN Mode: OFF — no delay
ON — 20 or 40 ms Delay
ON — 40 ms delay
Housing: Black ABS/polycarbonate blend; nylon fiber clip
mounts to standard 35 mm DIN rail
1 stainless steel right angle bracket and 1 PBT polyester bracket for mounting to flat surfaces also included
with sensor
Environmental Rating
Connections
IEC IP67; NEMA 6
Power: 2 m or 9 m PVC-jacketed 5-conductor cable or 5-pin Euro-style quick-disconnect (QD) connector
Fibers: Fiber clip (no tool required)
Temperature: -10° to +55° C (+14° to 131° F)
Maximum Relative Humidity: 90% at 50° C (non-condensing)
Operating Conditions
Application Notes
• Do not mount the fiber tip directly perpendicular to shiny surfaces; position it at approximately a 15° angle
in relation to the sensing target
• Minimize web or product “flutter” whenever possible to maximize sensing reliability
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 10
R55F Series Fiber-Optic Color Mark Sensors
R55F Series Sensor Hookups
Cabled Models
Quick-Disconnect Models
bn
bn
bu
wh
+
+
10-30V dc
–
10-30V dc
–
bu
wh
Load
Load
Load
bk
gy
bk
gy
Load
Remote Teach
Remote Teach
Mounting Brackets
Both brackets are included with sensor.
• Side-mounting bracket
SMBR55FRA
• Flat-mounting bracket
• Molded PBT polyester
SMBR55F01
• 19 ga stainless steel
7.2 mm
4x 5.0 mm
(0.28")
3.5 mm
(0.14")
(0.20")
40.0 mm
(1.58")
15.0 mm
(0.59")
29.5 mm
(1.16")
2x ø5.4 mm
(0.21")
(0.18")
6.0 mm
(0.24")
4.5 mm
65.0 mm
(2.56")
35.0 mm
(1.40")
50.8 mm
(2.00")
20.0 mm
(0.79")
35.0 mm
(1.38")
4x R2.5
(0.10")
30.4 mm
(1.20")
7.5 mm
(0.30")
2.5 mm
(0.10")
10.0 mm
(0.40")
4.5 mm
(0.18")
50.8 mm
(2.00")
64.0 mm
(2.52")
Quick-Disconnect (QD) Cables
Style
Model
Length
Connector
White Wire
MQDC1-506
MQDC1-515
MQDC1-530
MQDC1-506RA
MQDC1-515RA
MQDC1-530RA
2 m (6.5')
5 m (15')
9 m (30')
2 m (6.5')
5 m (15')
9 m (30')
Straight
Straight
Straight
Right-angle
Right-angle
Right-angle
Brown Wire
Blue Wire
Gray Wire
Black Wire
5-Pin Euro
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
page 11
R55F Series Glass and Plastic Fiber-Optic Color Mark Sensors
Euro-Style Field-Wireable Connectors
Contacts: Gold-plated; 4-pin models rated 250V ac/dc max., 4 A max.; 5-pin models rated 50V ac/dc max., 4A max.
Cable Diameter: 4.0 to 5.0 mm (0.16 to 0.20")
Temperature: -25° to +90°C (-13° to +194°F)
Environmental Rating: NEMA 6P, IP 67
Style
Model
Gender
Dimensions
Pin-out
60 mm
(2.4")
10 mm
(0.4")
20 mm
(0.8")
FIC-M12M5
Male
15.0 mm
(0.59")
M12 x 1
5-Pin
Straight
60 mm
(2.4")
10 mm
(0.4")
20 mm
(0.8")
FIC-M12F5
Female
Male
15.0 mm
(0.59")
M12 x 1
20 mm
(0.8")
41 mm
(1.6")
FIC-M12M5A
M12 x 1
30.5 mm
(1.20")
5-Pin
Right-angle
20 mm
(0.8")
FIC-M12F5A
Female
15.0 mm
(0.59")
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
!
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current
Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any
other warranty either expressed or implied.
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明