SGSA-S Series Enclosures
Datasheet
SGSA-S Series Enclosures for the mounted protection of SGS Grid Sensors and mirrors
•
•
•
•
•
•
Eight models available: four with corner mirrors, four to house SGS Grid Sensors
Models meet ANSI/RIA 15.06 and ISO 13855 standards for beam spacing
Robust aluminum housing with a tough safety yellow finish
Independently adjustable mirrors to simplify alignment
Circular bubble level on top of enclosure with three leveling screws in base
Base allows enclosure to rotate up to 20°
Banner SGSA-S Series Enclosures are designed specifically for use with Banner SGS Grid models. The enclosures are constructed of a powder
coated extruded aluminum housing with an anodized aluminum top plate and mounting base. The enclosures have leveling and rotational positioning
capabilities. Units with mirrors have three adjustment screws per mirror to optimize beam direction. The enclosures are available in eight different
models to accommodate ANSI/RIA 15.06 and ISO 13855 beam spacing standards. The rear-surfaced glass mirrors are rated at 85% efficiency per
mirror and reduce maximum range by 8% per mirror.
Important: Reduced Sensing Range—Sensing range is reduced to 85% efficiency per mirror (8% range per mirror).
WARNING:
•
•
Maintain the required separation distance
Failure to calculate this distance correctly and to maintain minimum separation distance can result in serious injury or
death.
•
The light screen produced by the optical safety system sensors must be placed at a minimum safe distance from the
dangerous motion of the machine being guarded. This necessary minimum distance is called the separation distance
and is discussed in the appropriate Grid manuals.
Models
Number of
Windows
Distance From Floor to
Bottom Window L2
Distance Between
Beams L3
Models
SGS Grid Models
SGSxx4-300Qxx
SGSxx3-400Qxx
SGSxx4-400Qxx
SGSxx2-500Qxx
Enclosure Height L1
1543 mm (60.75 in)
1238 mm (48.78 in)
1618 mm (63.69 in)
1035 mm (40.75 in)
Protected Height
900 mm (35.4 in)
800 mm (31.5 in)
1200 mm (47.2 in)
500 mm (19.7 in)
Application Standard
SGSA4-S300
ANSI/RIA R15.06
ISO 13855
4
3
4
2
300 mm (11.8 in)
300 mm (11.8 in)
300 mm (11.8 in)
400 mm (15.8 in)
300 mm (11.8 in)
400 mm (15.8 in)
400 mm (15.8 in)
500 mm (19.7 in)
SGSA4-S300-M
SGSA3-S400
ANSI/RIA R15.06
ISO 13855
SGSA3-S400-M
SGSA4-S400
ANSI/RIA R15.06
ISO 13855
SGSA4-S400-M
SGSA2-S500
ANSI/RIA R15.06
ISO 13855
SGSA2-S500-M
Model numbers with suffix -M include vertical mirrors for perimeter-guarding applications. For L1, L2, and L3 locations, see Figure 1 on page 1.
Install the Enclosure
145 mm
(5.7")
L3
L2
2X 120
3X 20
15
6X R6.60 mm
R (0.26")
Ø 177.8 mm
(7.00")
3X R83.8 mm
(3.30")
L1
Figure 1. SGSA-S enclosure dimensions
Figure 2. Base dimensions
Original Document
109308 Rev. C
12 April 2019
109308
SGSA-S Series Enclosures
M6 Spring Nut
M6 Lockwasher
M6 Screw
Figure 3. Installation of an SGS Grid System into the SGSA-S enclosure
1. Remove the front panel and top plate.
2. Position the SGS Grid with the mounting brackets over the spring nuts (supplied).
3. Fasten the sensors with the M6 lock washers and screws in four places.
4. Adjust the position of the sensor so that the bottom beam (between end of housing and status indicators) is the proper height above the
floor (see the figure for the proper distance).
5. Reinstall the top plate and front panel.
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge,
any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the
improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER
PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR
FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner
Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such
purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this
document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is
provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明