T30UXUB [BANNER]
T30UX Series with Analog Output;型号: | T30UXUB |
厂家: | Banner Engineering |
描述: | T30UX Series with Analog Output |
文件: | 总11页 (文件大小:583K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
U-GAGE T30UX Series with Analog Output
Datasheet
Ultrasonic Sensor with TEACH-Mode Configuration
•
1, 2 and 3 m (3.28, 6.56, and 9.84 ft) versions with short dead zones
(10% of max range)
•
•
Built-in temperature compensation
Fast, easy-to-use TEACH-Mode programming; no potentiometer
adjustments
•
•
•
•
•
Configure with either a positive or negative analog output slope
Remote TEACH for security and convenience
Wide operating temperature range of −40° to +70° C (−40° to +158° F)
Choose either 0 to 10V dc or 4 to 20 mA output model
Compact, self-contained, right-angle sensor package with fully
encapsulated electronics
Models
1
Models
Range and Frequency
Cable
Supply Voltage
Analog Output
0 to 10 V dc
4 to 20 mA
Response Time
T30UXUA
T30UXIA
T30UXUB
T30UXIB
T30UXUC
T30UXIC
100 mm to 1 m (3.9 in to 39 in)
224 kHz
45 ms or 105 ms selectable
200 mm to 2 m (7.8 in to 78 in)
174 kHz
0 to 10 V dc
4 to 20 mA
Standard 2 m
(6.5 ft) cable
10 to 30 V dc
92 ms or 222 ms selectable
135 ms or 318 ms selectable
300 mm to 3 m (11.8 in to 118 in)
114 kHz
0 to 10 V dc
4 to 20 mA
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Overview
®
The U-GAGE T30UX is an easy-to-use ultrasonic sensor with extended
Power ON/OFF
LED (Green)
Signal Strength
LED (Red)
range and built-in temperature compensation. Simple push button
configuration provides flexibility for a variety of applications.
Discrete Output
LED (Amber)
Easy-to-see indicator LEDs communicate the status of the sensor. The Green
“Power” LED ON indicates that the sensor is in Run Mode (the sensor’s
normal operating condition). The Red “Signal” LED indicates the target
signal strength. The Amber “Output” LED indicates that the output is
enabled and the sensor is receiving a signal within the window limits. The
Amber “Mode” LED indicates the currently selected mode(fast or slow).
Mode LEDs
(Amber)
Figure 1. Features
1
Only standard 2 m (6.5 ft) cable models are listed. To order the 4-Pin Euro-Style integral QD, add suffix “Q8” to the model number (for example,
T30UXUAQ8). To order the 150 mm (6 in) PUR pigtail cable with 4-Pin threaded Euro-Style QD, add suffix “QPMA” to the model number (for
example, T30UXUAQPMA). To order the 9 m (30 ft) cable, add suffix “W/30” to the model number (for example, T30UXUA W/30). A model
with a QD connector requires a mating cable; see Quick-Disconnect Cables on page 10.
Original Document
141958 Rev. E
19 September 2016
141958
®
U-GAGE T30UX Series with Analog Output
Principles of Operation
Ultrasonic sensors emit one or multiple pulses of ultrasonic energy, which travel through the air at the speed of sound. A
portion of this energy reflects off the target and travels back to the sensor. The sensor measures the total time required
for the energy to reach the target and return to the sensor. The distance to the object is then calculated using the
following formula: D = ct ÷ 2
D = distance from the sensor to the target
c = speed of sound in air
t = transit time for the ultrasonic pulse
To improve accuracy, an ultrasonic sensor may average the results of several pulses before outputting a new value.
Temperature Effects
The speed of sound is dependent upon the composition, pressure and temperature of the gas in which it is traveling. For
most ultrasonic applications, the composition and pressure of the gas are relatively fixed, while the temperature may
fluctuate.
In air, the speed of sound varies with temperature according to the following approximation:
In metric
units:
In English units:
C
=
√
=
C
ft/s
√
49 460 + T
F
20 273 + T
m/s
C
Cm/s = speed of sound in meters per second
TC = temperature in °C
Cft/s = speed of sound in feet per second
TF = temperature in °F
Temperature Compensation
Changes in air temperature affect the speed of sound, which in turn affects the total time for the echo measured by the
sensor. An increase in air temperature shifts both sensing window limits closer to the sensor. Conversely, a decrease in air
temperature shifts both limits farther away from the sensor. This shift is approximately 3.5% of the limit distance for a 20°
C change in temperature.
The T30UX series ultrasonic sensors are temperature compensated. This reduces the error due to temperature by about
90%. The sensor will maintain its window limits to within 2.2% over the -40° to +70° C (−40° to +158° F) operating
range of the sensor.
NOTE:
•
Exposure to direct sunlight can affect the sensor’s ability to accurately compensate for changes
in temperature.
•
If the sensor is measuring across a temperature gradient, the compensation will be less
effective.
Configuration Instructions
Sensor Configuration
Two TEACH methods may be used to configure the sensor:
•
•
Teach individual minimum and maximum limits, or
Use Auto-Window feature to center a sensing window around the taught position.
The sensor may be configured either via its push button, or via a remote switch. Remote configuration also may be used to
disable the push button, preventing unauthorized personnel from adjusting the configuration settings. To access this
feature, connect the white wire of the sensor to 0V dc, with a remote configuration switch between the sensor and the
voltage.
Configuration is accomplished by following the sequence of input pulses. The duration of each pulse (corresponding to a
push button “click”), and the period between multiple pulses, are as “T”: 0.04 seconds < T < 0.8 seconds
Remote line configuration requires a greater than 1 second pause between pulse sequences.
Mode Setup - Response Speed
Analog sensor models can be set up for either “Fast” or “Slow” response time. A button click or pulse on the remote line is:
0.04 s < T < 0.8 s.
1. Enter Response Speed Mode setup mode.
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 141958 Rev. E
®
U-GAGE T30UX Series with Analog Output
Method
Action
Result
Power LED: OFF
Push Button
Push and hold MODE push button for > 2 seconds.
Mode LED: Flashing Amber shows
previously selected mode
Power LED: OFF
T
T
Remote Input
Mode LED: Flashing Amber shows
previously selected mode
T
Double-pulse the remote line.
2. Select the speed.
Method
Action
Result
Power LED: OFF
Mode LED: Amber flashes to indicate
Push Button
Click the MODE button to cycle to the correct selection: Fast or Slow.
Single-pulse to select Slow; double-pulse to select Fast.
currently selected mode (120 second time
2
out )
Power LED: ON Green
Remote Input
Mode LED: ON Amber shows selected
mode (Sensor returns to RUN mode)
3. Save and return to Run mode.
Method
Action
Result
Power LED: ON Green
Push Button
Remote Input
Push and hold the MODE button for more than 2 seconds.
No action is required; the sensor will return to Run Mode.
Mode LED: ON Amber for selected mode
None
Analog Output
The U-GAGE T30UX series sensor may be configured for either a positive or a negative output slope, based on which
condition is taught first (see Figure 2 on page 3). If the near limit is taught first, the slope will be positive; if the far
limit is taught first, the slope will be negative. Banner’s scalable analog output automatically distributes the output signal
over the width of the programmed sensing window.
The U-GAGE T30UX also features a 2-second hold upon loss of the received signal, which is useful for harsh and unstable
applications. In the event of signal loss for longer than 2 seconds, the analog output goes to 3.6 mA or 0V dc, which may
be used to trigger an alarm.
Current-Sourcing Models
Voltage-Sourcing Models
20
10
Positive
Slope
Positive
Slope
Negative
Slope
Negative
Slope
4
0
Near
Window
Far
Window
Near
Window
Far
Window
Target Position
Target Position
Figure 2. Positive and Negative Output Slopes
Teaching Minimum and Maximum Limits
General Notes on Teaching
•
The sensor returns to RUN mode if the first TEACH condition is not registered within 120 seconds after the initial 2
second hold on the Analog button.
2
The sensor will revert to previously saved configuration and return to RUN mode if TEACH is inactive for 120 seconds after the initial 2 second
hold on push button
P/N 141958 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
3
®
U-GAGE T30UX Series with Analog Output
•
•
•
To exit TEACH mode without saving any changes, press and hold the Analog button or remote line longer than 2
seconds (before teaching the second limit). The sensor reverts to the last saved limits.
After the first limit is taught, the sensor remains in TEACH mode until the TEACH sequence is finished or exited by
a 2 second hold on the Analog button or remote line.
A button click or pulse on the remote line is: 0.04 s < T < 0.8 s.
1. Enter TEACH mode.
Method
Action
Result
Power LED: OFF
Output LED: ON
Push Button
Remote Input
Push and hold the Analog push button longer than 2 seconds.
No action required; sensor is ready for first limit teach.
None
2. Teach the first limit.
Method
Action
Position the target for the first limit (120 second time out).
Result
Signal LED: Must be ON Red or Flashing
3
Red
Teach Accepted
Push Button
Power LED: OFF
Output LED: Flashing
“Click” the Analog button.
Teach Not Accepted
Output LED: ON
Signal LED: Must be ON Red or Flashing
Red
Position the target for the first limit.
3
Teach Accepted
Remote Input
Power LED: OFF
Output LED: Flashing
T
Single-pulse the remote line.
Teach Not Accepted
Power LED: ON
3. Teach the second limit.
Method
Action
Result
Signal LED: Must be ON Red or Flashing
Red
Position the target for the second limit (no time out).
Teach Accepted
Output LED: ON
Power LED: ON
Push Button
“Click” the Analog button.
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Signal LED: Must be ON Red or Flashing
Red.
Position the target for the second limit (no time out).
Teach Accepted
Output LED: Turns ON
Power LED: ON
Remote Input
T
Single-pulse the remote line.
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Teaching Limits Using the Auto-Window Feature
Teaching the same limit twice automatically centers a 100 mm window on the taught position .
General Notes on Teaching
•
•
The sensor returns to RUN mode if the TEACH condition is not registered within 120 seconds after the initial 2
second hold on the Analog button.
To exit TEACH mode without saving any changes, press and hold the Analog button or remote line longer than 2
seconds (before teaching the second limit). The sensor will revert to the last saved limits.
3
Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 141958 Rev. E
®
U-GAGE T30UX Series with Analog Output
•
•
After the first limit is taught, the sensor remains in TEACH mode until the TEACH sequence is finished or exited by
a 2 second hold on the Analog button or remote line.
A button click or pulse on the remote line is: 0.04 s < T < 0.8 s.
1. Enter TEACH mode.
Method
Action
Result
Power LED: OFF
Output LED: ON
Push Button
Remote Input
Push and hold the Analog button longer than 2 seconds.
No action required; the sensor is ready for the first limit teach.
None
2. Teach the first limit.
Method
Action
Result
Signal LED: Must be ON Red or Flashing
Red
Position the target for the center of window (120 second time out).
4
Teach Accepted
Push Button
Power LED: OFF
Output LED: Flashing
Click the Analog push button.
Teach Not Accepted
Output LED: ON
Signal LED: Must be ON Red or Flashing
Red
Position the target for the center of window.
4
Teach Accepted
Single-pulse the remote line.
Remote Input
Power LED: OFF
T
Output LED: Flashing
Teach Not Accepted
Output LED: ON
3. Re-teach the limit.
Method
Action
Result
Teach Accepted
Output LED: ON
Power LED: ON
Push Button
Without moving the target, “click” the Analog push button again
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Teach Accepted
Without moving the target, single-pulse the remote line again.
Output LED: ON
Power LED: ON
T
Remote Input
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Remote Line TEACH
General Notes
•
•
Run Mode is the sensor’s normal operating condition
The duration of each Pulse is defined as “T”: 0.04 < T < 0.8 s
T
•
•
•
A Hold will exit TEACH MODE and return to Run Mode with previously saved changes. The duration of a Hold is: T
> 2 s
A Timeout will occur if a condition is not registered within 120 seconds, causing the sensor to return to Run Mode
(during sensor configuration only)
Sensor configuration user feedback shown on Green LED. See flowchart.
4
Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)
P/N 141958 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
5
®
U-GAGE T30UX Series with Analog Output
•
The Red Signal LED will be ON whenever the target is in view.
Power LED ON,
Exit
Run Mode All other LEDs in normal
operating condition
No valid target
1x
TEACH MODE
(1st pulse teaches 1st limit)
Power LED OFF,
Output LED Flashing
2 s Hold
1x
Power LED ON,
Output LED ON
Teach 2nd limit
No valid target
2x
Power LED OFF.
Mode LED Flashing
Output Configuration Menu
1x
2x
3x
Slow Speed (default)
Fast Speed
Slow LED ON
Fast LED ON
Positive Slope
(default)
Flash Power 3x,
Repeat twice
4x
Flash Power 4x,
Repeat twice
Negative Slope
2 s Hold
120 second Timeout
3x
Advanced Sensor
Configuration Menu
Power LED OFF,
Mode LEDs OFF
1x
Push button
enabled (default)
Flash Power 1x,
Repeat twice
2x
3x
Push button
disabled
Flash Power 2x,
Repeat twice
Temp. comp
enabled (default)
Flash Power 3x,
Repeat twice
4x
Temp. comp
disabled
Flash Power 4x,
Repeat twice
2 s Hold
120 second Timeout
4x
8x
Flash Power:
1x for enabled, Repeat twice
2x for disabled, Repeat twice
Toggle push button enable /disable
(legacy method)
Restore factory defaults
All LEDs off for 1 s
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 141958 Rev. E
®
U-GAGE T30UX Series with Analog Output
Wiring
1
3
4
+
10-30V dc
–
Wiring Key
1 = Brown
2 = White
3 = Blue
4-20 mA
or 0-10V
2
Remote
Teach
0-2V dc
4 = Black
Shield*
Cable and QD hookups are functionally identical. It is recommended that the shield wire be connected to earth ground.
Shielded cordsets are recommended for all QD models.
Specifications
Sensing Range
Minimum Window Size
“A” suffix models: 100 mm to 1 m (3.9 in to 39 in)
“B” suffix models: 200 mm to 2 m (7.8 in to 78 in)
“C” suffix models: 300 mm to 3 m (11.8 in to 118 in)
10 mm (0.4 in)
Adjustments
Sensing window limits: TEACH-Mode of near and far window limits
may be set using the push button or remotely via TEACH input.
Response speed selection: Fast or Slow (see Mode Setup - Response
Speed on page 2 or Remote Line TEACH on page 5)
Advanced configuration options: Analog output slope, push button
enabled/disabled, temperature compensation enabled/disabled (see
Remote Line TEACH on page 5)
Ultrasonic Frequency
“A” suffix models: 224 kHz
“B” suffix models: 174 kHz
“C” suffix models: 114 kHz
Supply Voltage
10 to 30 V dc (10% maximum ripple) at 40 mA, exclusive of load
Indicators
Supply Protection Circuitry
See Figure 1 on page 1
Protected against reverse polarity and transient voltages
Loss of Signal Indication
Output Configuration
0 to 10V dc models: Analog output goes to 0V
4 to 20 mA models: Analog output goes to 3.6 mA
Analog Output: 0 to 10V dc or 4 to 20 mA, depending on model
Output Rating
Construction
Analog Voltage Output: 2.5 kΩ min. load resistance; Minimum
supply for a full 10V output is 12V dc (for supply voltages between 10
and 12, V out max. is at least V supply -2)
Analog Current Output: 1 kΩ max. at 24V input; max. load
resistance = (Vcc-4)/0.02Ω
Housing: PBT polyester
Push buttons: polyester
Transducer: epoxy /ceramic composite
Environmental Rating
Leakproof design, ratedIEC IP67 (NEMA 6)
For current output (4-20 mA) models, ideal results are achieved
when the total load resistance
R = [(Vin – 4)/0.020]Ω. Example, at Vin = 24V dc, R ≈ 1 kΩ (1 watt)
Connections
2 m (6.5 ft) or 9 m (30 ft) shielded 4-conductor (with drain) PVC cable,
150 mm (6 in) PUR Euro-style pigtail (QPMA), or 4-pin integral Euro-
style connector (Q8)
Output Protection Circuitry
Protected against short circuit conditions
Temperature Effect
Linearity
0.02% of distance/°C
0.25% of distance
Delay at Power-up
Resolution
500 ms
“A” suffix models: 0.1% of distance (0.5 mm min.)
“B” suffix models: 0.1% of distance (1.0 mm min.)
“C” suffix models: 0.1% of distance (1.5 mm min.)
Output Response Time
“A” suffix models: 45 ms (fast); 105 ms (slow)
“B” suffix models: 92 ms (fast); 222 ms (slow)
“C” suffix models: 135 ms (fast); 318 ms (slow)
P/N 141958 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
7
®
U-GAGE T30UX Series with Analog Output
Operating Conditions
Required Overcurrent Protection
Temperature: −40 °C to +70 °C (−40 °F to +158 °F)
Humidity: 95% at +50 °C maximum relative humidity (non-
condensing)
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements method 201A (vibration:
10 to 60 Hz max., double amplitude 0.06 in, max acceleration 10G).
Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Certifications
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to http://
www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
Application Note
The temperature warmup drift upon power-up is less than 1% of the
sensing distance.
Performance Curves
With Plate Target (Typical)
1-Meter Models
2-Meter Models
3-Meter Models
200 mm
150 mm
100 mm
50 mm
0
8.0"
6.0"
4.0"
2.0"
0
400 mm
300 mm
200 mm
100 mm
0
16.0"
12.0"
8.0"
400 mm
16.0"
12.0"
8.0"
4.0"
0
300 mm
200 mm
100 mm
0
100 x 100 mm
100 x 100 mm
4.0"
100 x 100 mm
0
Width
Width
Width
100 mm
200 mm
300 mm
400 mm
4.0"
8.0"
12.0"
100 mm
200 mm
300 mm
400 mm
4.0"
8.0"
12.0"
16.0"
50 mm
100 mm
150 mm
200 mm
2.0"
4.0"
6.0"
8.0"
16.0"
0
400 mm
(16.0")
800 mm 1200 mm 1600 mm 2000 mm
0
600 mm 1200 mm 1800 mm 2400 mm 3000 mm
(24.0") (48.0") (72.0") (96.0") (120.0")
Distance
0
200 mm
(8.0")
400 mm
(16.0")
600 mm
(24.0")
800 mm 1000 mm
(32.0")
(32.0")
(48.0")
(64.0"
(80.0")
(40.0")
Distance
Distance
With Rod Target (Typical)
1-Meter Models
2-Meter Models
3-Meter Models
200 mm
150 mm
100 mm
8.0"
400 mm
300 mm
200 mm
100 mm
0
16.0"
400 mm
300 mm
200 mm
100 mm
0
16.0"
12.0"
8.0"
4.0"
0
12.0"
8.0"
4.0"
0
6.0"
4.0"
2.0"
0
25 mm Rod
25 mm Rod
25 mm Rod
50 mm
0
10 mm Rod
10 mm Rod
Width
Width
Width
10 mm Rod
100 mm
200 mm
300 mm
400 mm
4.0"
8.0"
12.0"
16.0"
100 mm
200 mm
300 mm
400 mm
4.0"
8.0"
12.0"
16.0"
50 mm
100 mm
150 mm
200 mm
2.0"
4.0"
6.0"
8.0"
0
400 mm
(16.0")
800 mm 1200 mm 1600 mm 2000 mm
(32.0") (48.0") (64.0") (80.0")
Distance
0
600 mm 1200 mm 1800 mm 2400 mm 3000 mm
(24.0") (48.0") (72.0") (96.0") (120.0")
Distance
0
200 mm
(8.0")
400 mm
(16.0")
600 mm
(24.0")
800 mm 1000 mm
(32.0") (40.0")
Distance
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 141958 Rev. E
®
U-GAGE T30UX Series with Analog Output
Maximum Target Rotation Angle
30
1 meter Target Rotation
2 meter Target Rotation
3 meter Target Rotation
20
10
0
Target Rotation
(Degrees)
10
20
30
0
500 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm
(20.0")
(40.0")
(60.0")
(80.0")
(100.0")
(120.0")
Distance
Dimensions
45.0
[1.77"]
22.5
[0.89"]
Ø40.2
[1.58"]
51.1
[2.01"]
63.6
[2.50"]
23.4
[0.92"]
M12 x 1
M30 x 1.5
Max. Torque 2.3 Nm (20 in-lbs.)
ø 15
[0.6"]
Locknut (included with all models)
10
Washer (included with all models)
M30 x 1.5
Ø40
[1.6"]
[0.4"]
Ø39.6
[1.56"]
1.6
[0.06"]
Ø30
[1.2"]
3x 36.1
[1.42"]
5
[0.2"]
P/N 141958 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
9
®
U-GAGE T30UX Series with Analog Output
Accessories
Quick-Disconnect Cables
4-Pin Threaded M12/Euro-Style Cordsets with Shield
Model
Length
Style
Dimensions
Pinout (Female)
MQDEC2-406
MQDEC2-415
1.83 m (6 ft)
4.57 m (15 ft)
44 Typ.
Straight
M12 x 1
MQDEC2-430
9.14 m (30 ft)
2
3
ø 14.5
1
4
MQDEC2-406RA
MQDEC2-415RA
1.83 m (6 ft)
4.57 m (15 ft)
32 Typ.
[1.26"]
1 = Brown
2 = White
3 = Blue
30 Typ.
[1.18"]
Right-Angle
4 = Black
MQDEC2-430RA
9.14 m (30 ft)
M12 x 1
ø 14.5 [0.57"]
Brackets
All measurements are in mm.
SMB30A
SMB1815SF
45
51
•
Right-angle bracket with
curved slot for versatile
orientation
Clearance for M6 (¼ in)
hardware
Mounting hole for 30 mm
sensor
12-ga. stainless steel
•
Swivel with set screws
for mounting sensors by
the cable hub
B
C
B
61
•
•
•
•
•
Black reinforced
thermoplastic polyester
Stainless steel swivel
locking hardware and
hex wrench included
39
A
69
A
25
Hole center spacing: A to B=40
Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5
Hole center spacing: A = 36.0
Hole size: A = ø 5.0, B = ø 15.0
SMB30FA
SMB30SC
67
83.2
•
Swivel bracket with tilt and
pan movement for precise
adjustment
Mounting hole for 30 mm
sensor
12-ga. 304 stainless steel
Easy sensor mounting to
extrude rail T-slot
•
•
•
Swivel bracket with 30 mm
mounting hole for sensor
Black reinforced
B
58
•
thermoplastic polyester
Stainless steel mounting and
swivel locking hardware
included
68.9
36.3
B
•
•
29
A
A
•
Metric and inch size bolt
available
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 -
1.5 x 50
Hole size: B= ø 30.1
10
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 141958 Rev. E
®
U-GAGE T30UX Series with Analog Output
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE
OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval
by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most
recent version of any documentation, refer to: www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明