WL50SGL20Q [BANNER]

WL50S High-Intensity Work Spot Light;
WL50SGL20Q
型号: WL50SGL20Q
厂家: Banner Engineering    Banner Engineering
描述:

WL50S High-Intensity Work Spot Light

文件: 总5页 (文件大小:287K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
WL50S High-Intensity Work Spot Light  
Datasheet  
General-purpose LED work lighting  
To view or download the latest technical information about this product, including specifications, dimensions, accessories,  
and wiring, see http://www.bannerengineering.com.  
Three lens options, depending on model, to vary spot size  
Illuminates a large area with an even pattern of light and no shadows  
12 to 30 V dc operation  
Cabled and quick-disconnect models available  
50 mm diameter with flat profile and 30 mm mounting base  
Rugged sealed housing rated to IP69K  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to  
serious injury or death. This device does not include the self-checking redundant circuitry necessary  
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an  
energized or de-energized sensor output condition.  
Models  
Model1  
LED Color  
Lumens  
Lux  
Lens Angle  
Connection  
0.5 m  
13780  
8000  
13000  
5460  
2500  
3900  
2000  
1040  
1700  
1 m  
3445  
2000  
3250  
1365  
625  
WL50SWL5Q  
WL50SRL5Q  
WL50SGL5Q  
WL50SWL11Q  
WL50SRL11Q  
WL50SGL11Q  
WL50SWL20Q  
WL50SRL20Q  
WL50SGL20Q  
White, 5000-8300 K  
Red, 620-630 nm  
Green, 520-535 nm  
White, 5000-8300 K  
Red, 620-630 nm  
Green, 520-535 nm  
White, 5000-8300 K  
Red, 620-630 nm  
Green, 520-535 nm  
295  
110  
210  
285  
105  
200  
270  
100  
190  
±5° (smaller,  
more focused  
spot; see graph)  
5 pin Euro integral  
QD connector (use  
with a 4-wire  
mating cordset;  
only 2 wires used  
for connection)  
±11° (larger  
spot; see graph)  
975  
500  
±20° (largest  
spot; see graph)  
260  
425  
1
Integral QD models only are listed. For integral 2 m (6.5') PVC cable, omit suffix Q from model number (example, WL50SWL5). A model with a QD  
requires a mating cordset (see 4-Pin Euro-Style Cordsets on page 3).  
Original Document  
158250 Rev. E  
21 April 2016  
158250  
WL50S High-Intensity Work Spot Light  
Specifications  
Supply Voltage and Current  
Environmental Rating  
Operating voltage: 12 V to 30 V dc  
Current draw: 400 mA maximum  
IEC IP67, IP69K per DIN 40050-9  
NOTE: Do not spray the cable with a  
Supply Protection Circuitry  
high-pressure sprayer or cable damage  
will result.  
Protected against reverse polarity and transient voltages  
Light Source  
Three high-intensity LEDs; see models table for color temperature or  
wavelengths  
Operating Conditions  
20 °C to +50 °C (4 °F to +122 °F)  
95% maximum relative humidity (non-condensing)  
Useful Life  
When operating within specifications, output will decrease less than  
30% after 50,000 hours.  
Vibration and Mechanical Shock  
All models meet Mil. Std. 202F requirements method 201A (vibration:  
10 to 60 Hz max., double amplitude 0.06", maximum acceleration  
10G). Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave.  
Construction  
Black anodized aluminum housing; polycarbonate window; nickel-  
plated QD connector or PVC-jacketed cable; black zinc-plated steel  
mounting nut  
Storage Temperature  
40 °C to +70 °C (40 °F to +158 °F)  
Mounting:  
Certifications  
30 × 1.5 mm thread base mount  
Connections  
Integral 5-pin M12 quick disconnect fitting or 2 m (6.5 ft) integral  
cable, depending on model; 4-pin connecting cordset required for quick  
disconnect fitting models; only 2 wires used  
UL Recognized for  
easy installation in  
control cabinets  
Beam Patterns  
Percentage of Maximum Light Intensity Per  
Lens Type at 0.5 Meter (Typical)  
Percentage of Maximum Light Intensity Per Lens Type at 1  
Meter (Typical)  
100%  
75%  
50%  
100%  
75%  
50%  
25%  
25%  
±5º  
±14˚  
±20º  
±11º ±14º  
±5˚  
±20˚  
±11˚  
0%  
–30  
0%  
60  
–20  
–10  
0
10  
20  
30  
50  
40  
30  
20  
10  
0
10  
20  
30  
40  
50  
60  
Light Pattern From Center (cm)  
Light Pattern From Center (cm)  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 158250 Rev. E  
WL50S High-Intensity Work Spot Light  
Dimensions  
Wiring  
Wiring Key:  
1 = Brown  
3 = Blue  
Female  
Male  
1
1
1
3
+
3
3
12–30 V dc  
4-Pin Euro-Style Cordsets  
4-Pin Threaded M12/Euro-Style Cordsets  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
MQDC-406  
MQDC-415  
MQDC-430  
1.83 m (6 ft)  
4.57 m (15 ft)  
9.14 m (30 ft)  
2
3
44 Typ.  
1
4
Straight  
M12 x 1  
ø 14.5  
1 = Brown  
2 = White  
3 = Blue  
MQDC-450  
15.2 m (50 ft)  
4 = Black  
P/N 158250 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
WL50S High-Intensity Work Spot Light  
4-Pin Threaded M12/Euro-Style Cordsets  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
MQDC-406RA  
MQDC-415RA  
MQDC-430RA  
1.83 m (6 ft)  
4.57 m (15 ft)  
9.14 m (30 ft)  
32 Typ.  
[1.26"]  
30 Typ.  
[1.18"]  
Right-Angle  
MQDC-450RA  
15.2 m (50 ft)  
M12 x 1  
ø 14.5 [0.57"]  
Mounting Brackets  
All measurements are in mm  
67  
45  
SMB30A  
SMB30SC  
Right-angle bracket with  
curved slot for versatile  
orientation  
Clearance for M6 (¼ in)  
hardware  
Mounting hole for 30 mm  
sensor  
12-ga. stainless steel  
Swivel bracket with 30 mm  
mounting hole for sensor  
Black reinforced  
B
C
61  
58  
thermoplastic polyester  
B
Stainless steel mounting and  
swivel locking hardware  
included  
A
29  
69  
A
Hole center spacing: A=ø 50.8  
Hole size: A=ø 7.0, B=ø 30.0  
Hole center spacing: A to B=40  
Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5  
SMB30FA  
SMBAMS30RA  
45  
83.2  
Swivel bracket with tilt and  
pan movement for precise  
adjustment  
Right-angle SMBAMS series  
bracket  
30 mm hole for mounting  
sensors  
Articulation slots for 90°+  
rotation  
12-ga. (2.6 mm) cold-rolled  
steel  
C
53  
A
Mounting hole for 30 mm  
sensor  
B
68.9  
36.3  
B
12-ga. 304 stainless steel  
Easy sensor mounting to  
extrude rail T-slot  
48  
A
Metric and inch size bolt  
available  
Hole center spacing: A=26.0, A to B=13.0  
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0  
Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 -  
1.5 x 50  
Hole size: B= ø 30.1  
45  
SMB30MM  
SMBAMS30P  
57  
70  
12-ga. stainless steel bracket  
with curved mounting slots  
for versatile orientation  
Flat SMBAMS series bracket  
30 mm hole for mounting  
sensors  
C
C
A
93  
57  
Clearance for M6 (¼ in)  
hardware  
Mounting hole for 30 mm  
sensor  
Articulation slots for 90°+  
rotation  
12-ga. 300 series stainless  
steel  
B
B
A
Hole center spacing: A = 51, A to B = 25.4  
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1  
Hole center spacing: A=26.0, A to B=13.0  
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0  
4
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 158250 Rev. E  
WL50S High-Intensity Work Spot Light  
Banner Engineering Corp Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following  
the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture  
which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty  
does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR  
IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A  
PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR  
TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO  
EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR  
ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR  
SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE  
PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY,  
NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any  
obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.  
Copyright Notice  
Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not  
intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product  
warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any  
©
time. For the most recent version of any documentation, refer to: www.bannerengineering.com.  
Banner Engineering Corp. All rights reserved.  
www.bannerengineering.com - Tel: +1-763-544-3164  

相关型号:

WL50SGL5Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SRL11Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SRL20Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SRL5Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWL11PWMQ

WL50S High-Intensity Spot Light - PWM Dimmable

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWL11Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWL20PWMQ

WL50S High-Intensity Spot Light - PWM Dimmable

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWL20Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWL5PWMQ

WL50S High-Intensity Spot Light - PWM Dimmable

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWL5Q

WL50S High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWSSGL11PWMQ

WL50S Stainless Steel High-Intensity Spot Light - PWM Dimmable

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WL50SWSSGL11Q

WL50S Stainless Steel High-Intensity Work Spot Light

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER