ABC601-1T28-S [BEL]

Universal input voltage range (85 – 305 VAC);
ABC601-1T28-S
型号: ABC601-1T28-S
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

Universal input voltage range (85 – 305 VAC)

文件: 总11页 (文件大小:1057K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The ABC601Series of industrial and medical AC-DCpower supplies  
provides up to 600 W of regulated output power through wide input  
voltage range 85 305 VAC in single outputs of 24, 28, 36 or 48  
VDC.  
The ABC601 Series comes in two packages, U-frame chassis or  
enclosed with a front mounted fan, offering 12 and 5 VSB standby  
outputs and a full set of protection features.  
The ABC601 Series features a built-in I-share circuit for parallel  
operationbetween power units to enhance total power. An optional  
OR-ing external circuit can be provided for N+1 redundant  
operation.  
The ABC601 Series complies with the latest international safety  
standards for IT and medical equipment and displays the CE-Mark  
for the European Low Voltage Directive (LVD).  
Universal input voltage range (85 305 VAC)  
Input surge current limiting  
800 W peak power (up to 10 s)  
High efficiency up to 94%  
24, 28, 36 and 48 VDC standard output voltages  
Low stand-by consumption (<0.35 W)  
Active PFC, EN 61000-3-2 compliant (Class C, >25% load)  
Low earth / touch leakage current  
Fan speed control circuit  
Over temperature, OV, OC and SC protections.  
Stand by +5 V, 1.5 A and auxiliary / fan 12 VDC, 1 A outputs  
Built-in current share signal for parallel operation  
Remote On / Off signal  
Power good and remote sense signals  
Medical safety approval to IEC 60601-1, 2x MoPP protection grade  
BF appliances compatible  
IEC 60601-1-2 4th edition EMC compliant  
IEC 62368-1 standards for Audio Video & IT equipment  
LED lighting approval to UL 8750  
RoHS 3 compliant (Directive EU 2015/863)  
Video Wall Display and SSL Lighting  
Industrial Process Control and Automation  
Telecommunications  
Laboratory / Analysis Equipment  
Test and Measurement Equipment  
Medical Applications  
2
ABC601 Series  
INPUTVOLTAGE NOM. OUTPUT MAX. OUTPUT MAX. OUTPUT  
MODELNUMBER PACKAGE & COOLING  
RANGE  
[VAC]  
VOLTAGE  
[VDC]  
POWER  
[W]  
CURRENT  
[A]  
DIMENSIONS  
Enclosed  
Front Mounted Fan  
U-Chassis  
Convection / Forced Air  
Enclosed  
Front Mounted Fan  
U-Chassis  
Convection / Forced Air  
Enclosed  
Front Mounted Fan  
U-Chassis  
Convection / Forced Air  
Enclosed  
107.0 x 206.0 x 41.0 mm  
4.21 x 8.11 x 1.6 in  
107.0 x 178.5 x 41.0 mm  
4.21 x 7.03 x 1.61 in  
107.0 x 206.0 x 41.0 mm  
4.21 x 8.11 x 1.6 in  
107.0 x 178.5 x 41.0 mm  
4.21 x 7.03 x 1.61 in  
107.0 x 206.0 x 41.0 mm  
4.21 x 8.11 x 1.6 in  
107.0 x 178.5 x 41.0 mm  
4.21 x 7.03 x 1.61 in  
107.0 x 206.0 x 41.0 mm  
4.21 x 8.11 x 1.6 in  
ABC601-1T24-S  
ABC601-1T24  
ABC601-1T28-S  
ABC601-1T28  
ABC601-1T36-S  
ABC601-1T36  
ABC601-1T48-S  
ABC601-1T48  
85 - 305  
85 - 305  
85 - 305  
85 - 305  
85 - 305  
85 - 305  
85 - 305  
85 - 305  
24  
24  
28  
28  
36  
36  
48  
48  
600  
600  
600  
600  
600  
600  
600  
600  
25  
25  
21.4  
21.4  
16.7  
16.7  
12.5  
12.5  
Front Mounted Fan  
U-Chassis  
Convection / Forced Air  
107.0 x 178.5 x 41.0 mm  
4.21 x 7.03 x 1.61 in  
PARAMETER  
DESCRIPTION / CONDITION  
MIN  
85  
NOM  
100-277  
-
MAX  
305  
300  
440  
UNIT  
VRMS  
VDC  
AC Input Voltage  
DC Input Voltage  
Input Frequency  
PS starts and operates at 85 VAC at all load conditions  
170  
47  
440 Hz with reduced PFC and output power rating.  
Consult factory for details.  
50/60  
Hz  
RMS at 180 VAC, maximum load, 50 / 60 Hz  
RMS at 85 VAC, maximum load, 50 / 60 Hz  
4.0  
8.5  
20  
Input Current  
-
-
A
115 VAC  
230 VAC  
-
-
-
-
Inrush Current  
Fusing  
Cold start, 25 °C ambient, full load  
A
A
30  
High breaking, 10 A, 250 V on each AC lines.  
-
-
10  
20% rated load  
50% rated load  
100% rated load  
89  
93  
92  
-
-
-
-
-
-
At 115 VAC  
Efficiency  
%
W
20% rated load  
50% rated load  
100% rated load  
90  
94  
94  
-
-
-
-
-
-
-
-
-
-
-
-
At 230 / 277 VAC  
Power on, 115 VAC, no load  
5
4
0.35  
Input Power Consumption Power on, 230 VAC, no load  
Stand by, 115, 230 VAC, no load  
Power Factor  
THDi  
From 50 to 100% of rated load, 230, 115 VAC, 50 / 60 Hz input voltages.  
From 50 to 100% rated load, 115, 230, 277 VAC 50 / 60 Hz.  
0.90  
-
-
-
-
-
20  
%
Complies with EN 61000-3-2 at 230 VAC, 50/60 Hz, Class A, D.  
Complies with EN 61000-3-2 Class C at 230 VAC, 50/60 Hz, >150 W load.  
Complies with EN 61000-3-3 at nominal voltages and full load.  
Normal conditions  
115 VRMS, 60 Hz  
230 VRMS, 50 Hz  
Harmonic Current  
Fluctuations and Flicker  
-
-
-
-
130  
240  
-
-
-
Earth Leakage Current  
µA  
264 VRMS, 60 Hz (worst case)  
277 VRMS, 60 Hz  
400  
-
-
264 VRMS, 60 Hz  
Touch Leakage Current  
Patient Leakage Current  
Normal Condition (NC)  
-
-
-
-
100  
500  
µA  
µA  
Single Fault Condition (SFC)  
264 VRMS, 60 Hz  
Normal Condition (NC)  
-
-
-
-
100  
500  
Single Fault Condition (SFC)  
tech.support@psbel.com  
3
ABC601 Series  
PARAMETER  
DESCRIPTION / CONDITION  
MIN  
NOM  
MAX  
UNIT  
24  
28  
36  
48  
±0.5% set pointaccuracy  
V1 Output Voltages  
-
-
V
RS+ closed on +V1, RS- closed on V1 RTN, at 20% load.  
Convection cooling (Refer to the de-rating curves below)  
Forced air cooling Refer to the de-rating curves below)  
Peak (less than 10 s, after P_OK high)  
400  
600  
800  
25.0  
21.4  
16.7  
12.5  
V1 Output Power Rating  
V1 Output Current  
W
A
V1: 24 VDC  
V1: 28 VDC  
V1: 36 VDC  
V1: 48 VDC  
V1 Voltage Adjustment Range  
V1 Line Regulation  
Manually by potentiometer  
-
-
-
-
-
-
±5  
±0.1  
±2  
%V1  
%V1  
%V1  
VAC  
VAC  
:
:
85 305 VRMS  
V1 Load-Line-Cross Regulation  
85 305 VRMS; I1: 0 100%  
Rated load, Peak-to-peak, 20 MHz BW.  
(100 nF ceramic, 10 µF tantalum at load) *  
25% load changes at 1 A/µs  
24 V at 1000 µF load / IOUT> 2.5 A  
28 V at 1000 µF load / IOUT> 2.5 A  
36 V at 680 µF load / IOUT> 1.9 A  
48 V at 560 µF load / IOUT> 1.25 A  
5 VSB at 560 µF load / IOUT> 0.1 A  
V1 Ripple and Noise  
-
-
1
%V1  
Transient Response:  
V1, 5VSB  
Voltage Deviation  
%V1  
-
-
±5  
%VSB  
V1 Start-up Rise Time  
V1 Hold-up Time  
85<VIN<305, any load conditions.  
10  
16  
-
-
100  
-
ms  
ms  
At nominal VIN, full load **  
Two units in parallel at I1 rated load.  
V1 Current Sharing Accuracy  
Start-up Delay  
VS-Logic and I-Share signals connected together.  
RS+, RS- signals connected together and to the load  
V1 in regulation after de-asserting PS_Inhibit  
V1 in regulation after AC is applied (worst case: 85 VAC  
45.5  
-
54.5  
%I1  
ms  
-
-
-
-
-
-
-
-
-
-
450  
2050  
1500  
10  
)
5 VSB in regulation after AC is applied (worst case: 85 VAC  
)
%V1  
%VSB  
Turn-on Overshoot  
Minimum Load  
10  
V1, V2, 5VSB  
0
-
-
A
V1: 24 VDC  
V1: 28 VDC  
V1: 36 VDC  
V1: 48 VDC  
-
-
-
-
-
-
-
-
16000  
15000  
12000  
8000  
Maximum Load Capacitance  
µF  
V2 Output Voltage  
V2 Output Current  
5 VSB Output Voltage  
V1 at nominal voltage  
10.5  
12.25  
14.00  
V
A
V
Convection / forced air cooling  
±3% set point accuracy, 20% load.  
-
-
-
1
-
5
Front Mounted Fan models (-S)  
U-Chassis models  
-
-
-
-
1.5  
1.2  
5 VSB Output Current  
A
5 VSB Load, line cross Regulation VAC: 85 305 VRMS; ISB: 0 100%  
-
-
±5  
%VSB  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.01063_B  
4
ABC601 Series  
Natural Convection  
U-Chassis Models  
Vertical Mounting  
180 305 VAC  
Natural Convection  
U-Chassis Models  
Horizontal Mounting  
180 305 VAC  
Forced Air Cooling  
U-Chassis Models  
>500 LFM  
At 180 305 VAC  
>600 LFM  
At 85 180 VAC  
Enclosed Front Mounted  
Fan Models  
85 305 VAC  
Natural Convection  
Any Orientation  
85 305 VAC  
tech.support@psbel.com  
5
ABC601 Series  
Base signals and controls are accessible from signal connector P204.  
SIGNAL  
DESCRIPTION / CONDITION  
MIN  
0
NOM  
MAX  
1.5  
UNIT  
+PS_Inhibit  
Active high. Input low voltage  
-
-
V
V
Input high voltage (IIN = 300 µA)  
3.5  
5.5  
V1 and V2 disabled when PS_Inhibit is pulled high  
5VSB not affected by PS_Inhibit  
V1 and V2 enabled when PS_Inhibit is open or low  
Active low (reverse control, same voltage levels)  
Logic level low(<10 mA sinking)  
-PS_Inhibit  
P_OK *  
-
2.4  
40  
1
-
-
-
-
-
0.7  
5.5  
350  
-
V
Logic level high (100 µA sourcing)  
V
Low to high time after V1 in regulation  
Power down warning time  
ms  
ms  
ms  
5VSB Output  
Active and in regulation after a 85 < VAC < 305 is applied  
5VSB not affected by PS_Inhibit  
-
1500  
* When V1 is On, a P_OK low may indicates V1 under voltage condition. When two ABC601 operate in parallel, P_OK low in oneunit  
indicates that it is not sharing the expected amount of current (current sharing fault). A 10 kΩ internal pull up to 5VSB is used; do not add  
any other external pull up.  
AC/DC INPUT OFF-TO-ON AND ON-TO-OFF TIMINGS  
5VSB On V1 On  
250 ms T1 550 ms  
10 ms T2 100 ms  
3 ms T10 40 ms  
200 ms T3 350 ms  
T4 1 ms  
V1 rise time  
5VSB rise time  
V1 On POWER_OK delay  
Power down warning  
V1 Off 5VSB Off  
T5 0.5 s (V1 load > 25 W)  
T6 15 ms  
AC Off POWER_OK low  
AC_On 5VSB turn on time  
T7 1.5 s  
North America  
Asia-Pacific  
+86 755 298 85888  
Europe, Middle East  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.01063_B  
6
ABC601 Series  
PS_INHIBIT OFF-TO-ON AND ON-TO-OFF TIMINGS  
V1 rise time  
10 ms T2 100 ms  
200 ms T3 350 ms  
T4 1 ms  
V1 On POWER_OK delay  
Power down warning  
PS_Inhibit POWER_OK lowtiming  
PS_Inhibit V1 On delay  
T8 2 ms  
T9 450 ms  
tech.support@psbel.com  
7
ABC601 Series  
PARAMETER  
Input Under Voltage  
Input Fuse  
DESCRIPTION / CONDITION  
Auto-recovering, hiccup mode.  
High breaking, 10 A, 250 V on L and L1.  
MIN  
58  
-
NOM  
MAX  
75  
UNIT  
65  
-
VAC  
A
10  
At nominal input voltages  
V1: Hiccup mode, auto-recovering (>10 s)  
V1: Hiccup mode, auto-recovering (<10 s)  
V2: PTC limiting, auto-recovering.  
5VSB: Hiccup mode, auto-recovering:  
U-Chassis models  
108  
135  
-
-
-
-
132  
163  
-
%I1Rated  
%I1Rated  
Over Current  
1.3  
1.6  
-
-
3.6  
3.6  
A
A
Front Mounted Fan models (-S)  
At nominal input voltages  
V1: Hiccup mode, auto-recovering.  
V2: PTC limiting, auto-recovering.  
5VSB: Hiccup mode, auto-recovering.  
V1, Power shut down, latch off.  
5VSB, Hiccup mode, auto-recovering.  
Short Circuit  
Over Voltage  
-
-
-
120  
-
-
-
145  
150  
%VNOM  
Over Temperature (on primary stage)  
Over Temperature (on secondary side)  
Shut down, latch off.  
-
-
-
°C  
°C  
Hiccup mode, auto-recovering.  
-
-
-
Reinforced (2x MoPP).  
Production tested at 4242 VDC  
Basic (1x MoPP)  
5660  
4000  
2121  
1500  
-
-
-
-
-
-
-
-
VDC  
VAC  
VDC  
VAC  
Isolation: Input-to-Output  
Isolation: Input-to-Earth  
Isolation: V1/5VSB to V2  
Production tested at 2121 VDC  
Basic  
100  
-
-
VAC  
Isolation: Output-to-Earth  
Means of Protection:  
Basic (1x MoPP)  
1500  
-
-
VAC  
2x MoPP (IEC 60601-1 3rd edition) at 100 250 VAC, 50/60 Hz up to 4000 m  
2x MoPP (IEC 60601-1 3rd edition) at 100 277 VAC, 50/60 Hz up to 3000 m  
2x MoOP (IEC 60601-1 3rd edition) at 100 277 VAC, 440 Hz (50/60 Hz)  
1x MoPP (IEC 60601-1 3rd edition) at 100 250 VAC, 50/60 Hz up to 4000 m  
1x MoPP (IEC 60601-1 3rd edition) at 100 277 VAC, 50/60 Hz up to 3000 m  
1x MoOP (IEC 60601-1 3rd edition) at 100 277 VAC, 440 Hz (50/60 Hz)  
1x MoPP (IEC 60601-1 3rd edition) at 100 250 VAC, 50/60 Hz up to 4000 m  
Primary to secondary  
Means of Protection:  
Primary to ProtectionEarth  
Means of Protection:  
1x MoPP (IEC 60601-1 3rd edition) at 100 277 VAC, 50/60 Hz up to 3000 m (U-chassis variant only)  
1x MoOP (IEC 60601-1 3rd edition) at 100 277 VAC, 440 Hz (U-chassis variant only)  
Secondary to Protection Earth  
Equipment Protection Class  
Class I, compatible with BF (Body Floating) ME  
PARAMETER  
DESCRIPTION / CONDITION  
MIN  
NOM  
MAX  
UNIT  
Operating Temperature Range No de-rating up to 50°C  
Operating Temperature Range  
-20  
-
50  
°C  
See derating curves & conditions in the Output Specifications section  
-
-40  
-
-
-
-
70  
°C  
with Derating  
Storage Temperature  
TransportationTemperature  
As per IEC/EN 60721-3-1 Class 1K4  
As per IEC/EN 60721-3-2 Class 2K4  
RH, Non-condensing Operating.  
Non-operating  
85  
°C  
90  
95  
%
%
Humidity  
MoPP (100 250 VAC, 50/60 Hz)  
MoPP (100 277 VAC, 50/60 Hz)  
MoOP, ITE grade  
-
-
-
-
-
-
4000  
3000  
5000  
Operating Altitude  
m
Power de-rating above1800 m  
EN 60068-2-27  
Shock  
Operating:  
Non-Operating: Half sine, 50 g, 11 ms, 3 axes, 6x each (3 positive and 3 negative).  
EN 60068-2-64  
Operating:  
Half sine, 30 g, 18 ms, 3 axes, 6x each(3 positive and 3 negative).  
Sine,10 500 Hz, 1 g, 3 axes, 1 oct/min., 60 min.  
Vibration  
Random, 5 500 Hz, 0.02 g2/Hz, 1 gRMS, 3 axes, 30 min.  
Non-Operating: 5 500 Hz, 2.46 gRMS (0.0122 g2/Hz), 3 axes, 30 min.  
Full Load, 40 °C ambient  
80% Duty cycle, Telcordia SR-332 Issue 2  
MTBF  
300000  
-
-
-
Hours  
Years  
Useful Life  
Nominal VIN, 80% load, 40 °C ambient (IPC9592)  
-
4
North America  
Asia-Pacific  
+86 755 298 85888  
Europe, Middle East  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.01063_B  
8
ABC601 Series  
PERFORMANCE  
CLASS  
PARAMETER  
DESCRIPTION / CONDITION  
STANDARD  
EN 55022 (ITE)  
EN 55011 (ISM)  
EN 60601-1-2 (Medical)  
FCC Part 15  
Conducted  
115, 230, 277 VRMS, Maximum load  
B
EN 55022 (ITE)  
EN 55011 (ISM)  
EN 60601-1-2 (Medical)  
FCC Part 15  
Radiated  
At 10 m distance  
B *  
At 20%, 50% and 100% maximum load.  
Nominal input voltages  
230 VAC input voltage, 50 / 60 Hz  
230 VAC 50 / 60 Hz, >150 W load  
Line Voltage Fluctuation& Flicker  
Harmonic Current Emission  
EN 61000-3-3  
EN 61000-3-2  
EN 61000-3-2  
A, D  
C
* Performance referred to the enclosed package. Radiated emission relevant to the U-Chassis package, should be assessed at system level.  
PARAMETER  
DESCRIPTION / CONDITION  
STANDARD  
EN 60601-1-2, 4th edition  
EN 55024  
TEST LEVEL  
CRITERIA  
Reference standard for the medical version  
Reference standards for ITE  
Reference standard for Industrial/IMS equipment  
EN 61000-6-2  
15 kV air discharge, 8 kV contact,  
ESD  
EN 61000-4-2  
4
3
A
A
at any point of the system.  
10 V/m, 80-1000 MHz, 1 kHz/2 Hz 80% AM.  
Dwell time is 3 sec for 2 Hz modulation  
Dwell time is 1 sec for 1 kKHz modulation  
Radiated Field  
EN 61000-4-3  
EN 61000-4-4  
Electric Fast Transient  
Surge  
±2 kV on AC power port for 1 minute  
3
4
3
A
A
A
±2 kV line to line; ± 4 kV line to earth on AC power port EN 61000-4-5  
Conducted RF Immunity  
10 VRMS, 0.15-80 MHz, 1 kHz, 80% AM  
EN 61000-4-6  
Drop-out to 0% for 10 ms  
Dip to 40% for 5 cycles (100 ms)  
Dip to 70% for 25 cycles (500 ms) EN61000-4-11  
Drop-out to 0% for 5 s  
EN61000-4-11  
EN61000-4-11  
A
A
A
B
200 277 VAC  
100 127 VAC  
:
:
EN61000-4-11  
Dips and Interruptions  
Drop-out to 0% for 10 ms  
Dip to 40% for 5 cycles (100 ms)  
Dip to 70% for 25 cycles (500 ms) EN 61000-4-11  
Drop-out to 0% for 5 s  
EN 61000-4-11  
EN 61000-4-11  
A
A (derate to 150 W)  
A (derate to 400 W)  
B
EN 61000-4-11  
CERTIFICATION BODY SAFETY STANDARDS  
CATEGORY  
Audio Video and Information  
Technology Equipment  
CSA/UL  
CSA C22.2 No. 60950-1, UL 60950-1 and UL 62368-1  
CSA C22.2 No.60601-1, ANSI/AAMI ES60601-1 3rd edition + A1  
Including Risk Management Assessment  
Medical  
UL8750, CSA C22.2 No 250.13  
Lighting  
Audio Video and Information  
Technology Equipment.  
Medical  
IEC IECEE  
CB Certification  
IEC/EN 60950-1 and IEC/EN 62368-1  
IEC/EN 60601-1 3rd edition+A1 Including Risk Management Assessment  
Audio Video and Information  
Technology Equipment  
CE  
Directive 2014/35/EU: Electrical Safety: LowVoltage electrical equipment (LVD)  
Directive 93/42/CEE: Safety Requirement ofthe Medical Device  
Directive 2014/30/EU: Electromagnetic Compatibility (EMC)  
Directive EU 2015/863: RoHS 3  
Medical  
Designed to meet IEC/EN/UL/CSA 61010-1 2nd edition  
tech.support@psbel.com  
9
ABC601 Series  
PARAMETER  
DESCRIPTION / CONDITION  
820 g (1.8 lb)  
1055 g (2.32 lb)  
Weight  
107.0 x 178.5 x 41.0 mm (4.21 x 7.03 x 1.61 in)  
107.0 x 206.0 x 41.0 mm (4.21 x 8.11 x 1.61 in)  
Overall Dimensions  
Figure 1. Mechanical drawing - U-Chassis Model  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.01063_B  
10  
ABC601 Series  
Figure 2. Mechanical drawing Front Mounted Fan Models (-S)  
tech.support@psbel.com  
11  
ABC601 Series  
AC INPUT CONNECTOR P1  
PIN REF.  
FUNCTION  
Molex 26-62-4051  
Mates with  
1
3
5
L1  
L
Molex 09-93-0500 (housing)  
Molex 08-52-0071 (terminal phosphor bronze, tin finishing)  
Use 18 AWG minimum wires  
PE  
DC OUTPUT CONNECTOR P2  
KARSON 520-041-2-1-00  
Or equivalent  
PIN REF.  
1 2  
FUNCTION  
+V1  
3 4  
V1 RTN  
SIGNAL CONNECTOR P3  
PIN REF.  
FUNCTION  
RTN  
Molex 90130-1112  
Mates with  
Molex 90142-0012 (housing)  
Molex 90119-0109 (terminal)  
Use 22-24 AWG wires  
1
2
-V2  
3
+5VSB  
4
+V2  
5
RS-  
6
RS+  
7
+PS_Inhibit  
I-Share  
P_OK  
8
9
10  
11  
12  
VS_Logic  
-PS_Inhibit  
RTN  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.01063_B  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY