ACC600-1T24 [BEL]

5 x 8.5 x 1.61 Inch Form Factor (127 x 216 x 41 mm);
ACC600-1T24
型号: ACC600-1T24
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

5 x 8.5 x 1.61 Inch Form Factor (127 x 216 x 41 mm)

文件: 总12页 (文件大小:1279K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The ACC600 Series of open frame power supplies feature a wide  
universal AC input range of 85 264 VAC, offering up to 600 W of  
output power with convection cooling (U-Channel), in a compact  
footprint, with a variety of single output voltages.  
The high efficiency and high power density of the ACC series ensures  
minimal power loss in end-use equipment, thereby facilitating higher  
reliability, easier thermalmanagementand meets regulatory approvals  
for environmentally-friendlyend products.  
These power supplies are ideal for medical, telecom, datacom,  
industrial equipment and other applications.  
5 x 8.5 x 1.61 Inch Form Factor (127 x 216 x 41 mm)  
Convection Cooling Rated  
Universal Input  
Current Sharing Option  
Peak Power Capability  
5 VDC Stand by output  
12 V fan output  
Power Good / Power Fail Signal  
Suitable in POE applications  
Lesser than 1U high  
High voltage output range up to 58 VDC  
N+1 redundant power supply  
Single wire current sharing  
Built in OR-ing diode / FET (- R suffix)  
Instrumentation  
Lighting  
Renewable Energy  
Test and Measurement  
Robotics  
Industrial Applications  
Applied Computing  
Wireless Communication  
2
ACC600 Series  
ACC600-1T12  
U-Channel  
25 A  
17.5 A  
15 A  
ACC600-1T12-H  
ACC600-1T12-P  
ACC600-1T15  
ACC600-1T15-H  
ACC600-1T15-P  
ACC600-1T24  
ACC600-1T24-H  
ACC600-1T24-P  
ACC600-1T30  
ACC600-1T30-H  
ACC600-1T30-P  
ACC600-1T48  
ACC600-1T48-H  
ACC600-1T48-P  
ACC600-1T58  
ACC600-1T58-H  
ACC600-1T58-P  
12 V  
15 V  
24 V  
30 V  
48 V  
58 V  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
U-Channel  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
U-Channel  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
U-Channel  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
U-Channel  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
U-Channel  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
0.0 A  
0.0 A  
0.0 A  
0.0 A  
0.0 A  
0.0 A  
2%  
2%  
2%  
2%  
2%  
2%  
25 A  
17.5 A  
15 A  
25 A  
17.5 A  
15 A  
20 A  
14 A  
12 A  
12.5 A  
8.75 A  
7.5 A  
10.34 A  
7.25 A  
6.2 A  
1
To order product without theredundancy diode option pleaseadd thesuffix-Sxxxto your requiredpart number.  
Please contact thefactory for availability.  
For Ripplemeasurement minimumoutput power requirement is 25 W.  
2
Ripple is peak to peak with 20 MHz bandwidth and10 µF (Electrolyticcapacitor)in parallel with a 0.1 µF capacitor at rated linevoltageand  
load ranges.  
Specifications are for nominal input voltage, 25°C unless otherwise stated.  
Input Voltage  
Universal  
85 264 VAC / 120 390 VDC  
47 63 Hz  
Input Frequency  
Input Current  
120 VAC:  
240 VAC:  
6.5 A max.  
3.2 A max.  
Input Protection  
No Load Power  
In Live & Neutral both  
F16 A / 250 V  
Over entire input range with main output kept  
OFF using RemoteON/OFF  
3 W typ.  
Inrush Current  
Leakage Current  
Touch Current:  
240 VAC:  
25 A max.  
400 µA  
240 VAC / 50 Hz  
< 100 µA  
120 VAC:  
240 VAC:  
0.98  
0.95  
Power Factor  
PFC converter: Variable  
Resonant converter: Variable  
85 kHz typical  
100 kHz typical  
Switching Frequency  
tech.support@psbel.com  
3
ACC600 Series  
Output Voltage  
Standby Output Voltage3  
Refer to Model Selection table for details  
12 V to 58 V  
5 V  
U-Channel  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
600 W  
Output Power4  
Convection Cooled  
420 W  
360 W  
120 VAC:  
240 VAC:  
88% Typical  
93%  
Efficiency  
Hold-up Time  
Line Regulation  
Load Regulation  
120 VAC / 240 VAC:  
8 ms  
± 0.5%  
± 1.0%  
< 10%,  
recovery time < 5 ms  
Transient Response  
50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/μs  
Voltage Adjustment  
Set Point Tolerance  
Rise Time  
± 3%  
± 1%  
<100 ms  
110%  
114%  
Over Current Protection  
Over Voltage Protection  
Short Circuit Protection  
Over Temperature Protection  
Current Share  
Hiccup Type, autorecovery  
Latch Type, AC Power to be recycled for recovery  
Latch Type, AC Power to be recycled for recovery  
Autorecovery  
130 - 140°C primary heat sink  
Up to 3 supplies connected in parallel (optional)  
U-Channel  
Convection  
600 W  
420 W  
360 W  
Cooling  
U-Channel + Slotted Cover  
U-Channel + Plain Cover  
3
Standby output voltage5 V / 1.5 A (convection)with toleranceincluding set point accuracy, lineand loadregulation is +/-10%.Rippleand  
noiseis less than 5%.  
Combinedoutput power of main output,fan supply and standby supply shall not exceed max. power rating.  
4
Conducted Emissions  
Radiated Emissions  
EN 55032  
EN 55032  
Class B  
Class A  
Class B  
With External king core K5BRC 25x12x15-M or equivalent:  
Input Current Harmonics  
Voltage Fluctuation and Flicker  
ESD Immunity  
EN 61000-3-2  
EN 61000-3-3  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
EN 61000-4-11  
Class A  
Pass  
A
Radiated Field Immunity  
Electrical Fast Transient Immunity  
Surge Immunity  
A
A
A
Conducted Immunity  
A
Magnetic Field Immunity  
Voltage Dips, Interruptions  
A
A & B  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00970_B  
4
ACC600 Series  
Input to Output  
Input to Earth  
4000 VDC  
2500 VDC  
Isolation Voltage  
IEC/EN 62368-1, ED 2  
Safety Standard(s)  
Agency Approvals  
CE mark  
UL 62368-1, CSA C22.2 No. 62368-1  
Nemko, UL, C-UL  
Complies with LVD Directive  
Operating Temperature  
Storage Temperature  
Relative Humidity  
Refer to derating curves  
Non-condensing  
-40 to +70°C  
-40 to +85°C  
5% to 95%  
Operating:  
Non-operating:  
16,000 ft.  
40,000 ft.  
Altitude  
MTBF  
Telcordia -SR332-issue 3  
3.37 million hours  
Power Good: Is a TTL signal which goes high after mainoutput reaches 90% of its set value.  
The delay is 0.1 s to 0.5 s  
Power Good / Fail Signal  
Remote Sense  
Power Fail: Thesame signal goes low at least 1ms beforemain output falls to 90% ofset value at AC Power off  
Compensates for 200 mV drop  
Pin 6 & Pin 7 of J3 can be used for Remoteon/off.  
Shorting Pin 6 to Pin 7 enables main output while keeping the pins open disables main output  
Note: Provision of Inhibit RemoteON/OFF is available. +5 V at Pin 7 will switch offthe main output.  
Remote On / Off  
OCP Limit Set  
Pin 8 & Pin 9 of J3 must be left open  
Figure 1. Power Good / Fail Signal Diagram  
tech.support@psbel.com  
5
ACC600 Series  
Pin 1  
Pin 2  
Pin 3  
AC Line  
Neutral  
Earth  
AC Input Connector  
DC Output Connector  
J1  
J2  
TE Connectivity: NC6-P107-03  
6-32 inches Screw Pan HD  
Mating: Designed to accept Ring Tongue Terminal AMP: 8-31886-1,  
wherein one 16 AWG (max) wire can be crimped.  
Note: One Ring TongueTerminal with 16 AWG is recommended for  
current up to 11 A only.  
J2-A  
J2-B  
+VE  
-VE  
Use multiple tongue terminals with wire for more current.  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Pin 9  
Pin 10  
GND  
5V AUX  
PGPF  
VS –  
VS +  
GND  
RMT  
CL2  
Molex: 22-23-2101  
Mating: 22-01-2107; Pins: 08-50-0113  
Signal Connector  
J35  
CL1  
LS  
TE Connectivity AMP Connectors  
Description: CONN HEADERVERT 2 POS 2.54 mm,  
Pin 1  
Pin 2  
+VE  
-VE  
Fan Output6  
J10, J11  
MPN: 640456-2  
Mating: 3-641535-2 / TE Connectivity AMP Connectors  
or: 0022013027 / MOLEX with crimping 08-50-0114 / MOLEX  
5
PSU is suppliedwith J3, pin-6 andpin-7 shortedto enable main output without remoteon/off feature.  
Fan supply output voltageis 12 V / 500 mA with regulation band+/-30 % andRippleis less than 10%. To get 12 V Fan supply output voltage,  
minimum10 % load on Main output voltageis required.  
6
Weight  
Dimensions  
1100 g  
127 x 216 x 41 mm (5.0 x 8.5 x 1.61 inches)  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00970_B  
6
ACC600 Series  
Figure 2. Mechanical drawing - U-Channel  
tech.support@psbel.com  
7
ACC600 Series  
Figure 3. Mechanical drawing - U-Channel + Slotted Cover  
North America  
Asia-Pacific  
+86 755 298 85888  
Europe, Middle East  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00970_B  
8
ACC600 Series  
Figure 4. Mechanical drawing - U-Channel + Plain Cover  
tech.support@psbel.com  
9
ACC600 Series  
Figure 5. Power Derating w.r.t. Input  
Figure 6. Power Derating Curve 12 V  
Convection load: 300 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Figure 7. Power Derating Curve 12 V with Slotted Cover  
Figure 8. Power Derating Curve 12 V with Plain Cover  
Convection load: 210 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Convection load: 180 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00970_B  
10  
ACC600 Series  
Figure 9. Power Derating Curve 15 V  
Convection load: 375 W up to 30 °C  
De-rate between 30-50 °C @ 0.8133% per °C  
De-rate above 50 °C @ 2.5% per °C  
Figure 10. Power Derating Curve 15 V with Slotted Cover  
Figure 11. Power Derating Curve 15 V with Plain Cover  
Convection load: 262.5 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Convection load: 225 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
tech.support@psbel.com  
11  
ACC600 Series  
Figure 12. Power Derating Curve 24 V and above  
Convection load: 600 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Figure 13. Power Derating Curve 24 V and above with Slotted Cover  
Figure 14. Power Derating Curve 24 V and above with Plain Cover  
Convection load: 420 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Convection load: 360 W up to 30 °C  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00970_B  
12  
ACC600 Series  
During the installation and setup of parallel supplies in a system it is important that a single remote sense point be used for all the  
supplies. The remote sense voltage between the supplies must be adjusted to within 1% to ensure the supplies are inside the 1%  
capture window. If the supplies are not initially adjusted inside the capture window the supplies will not current share satisfactorily.  
SET-UP PROCEDURE:  
1. Connect load cables to the outputs of each supply.  
2. Connect the remote sense lines to the load in twisted style. (A common remote sense point must be used for all the supplies  
in parallel).  
3. Connect all the “LS” signal (Pin 10) on the J3 connector between the supplies.  
4. Adjust remote sense voltage of each supply to within 1% of rated output voltage or readjust to required set point. (Adjustment  
to be done with all other parallel supplies off).  
5. Current sharing between the supplies can be verified by monitoring the output current of each supply with a hall effect DC  
current probe. The supplies should share to within 10% of the total load current.  
6. The current share circuit has a capture window voltage of +/- 1% of the rated output voltage. If the output remote sense  
voltage of one of the supplies is adjusted outside the 1% window the supplies will not current share satisfactorily.  
Figure 15. Current Sharing Block Diagram  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY