HES075YD-ANT92V [BEL]

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, HALF BRICK PACKAGE-9;
HES075YD-ANT92V
型号: HES075YD-ANT92V
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, HALF BRICK PACKAGE-9

文件: 总3页 (文件大小:101K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HES DC/DC Series Data Sheet  
Half-Brick Converters  
Description  
HES single-output DC/DC converters provide up to 150  
watts of output power in an industry-standard, half-brick  
package and footprint. These units feature ultra-high  
efficiency, Class A conducted noise specifications, and  
fixed switching frequency. The HES is designed with  
open-frame packaging, along with planar magnetics to  
provide maximum useable power with minimal thermal  
constraints. The HES is especially suited to harsh  
telecom, networking, and industrial applications, and is  
fully compatible with production board washing processes.  
Features  
• High efficiency  
• Industry standard half-brick • “True-Trim” option  
• Open-frame packaging • 1500V isolation  
• 100°C baseplate operation • Positive or negative  
logic  
• Water washable  
Technical Specifications  
Input  
Voltage Range  
24 VDC Nominal  
48 VDC Nominal  
Reflected Ripple  
18 - 36 VDC  
36 - 72 VDC  
50 mA  
Input Reverse Voltage Protection  
Input Undervoltage Lockout / Hysteresis  
Shunt Diode  
<34V/1V Nom.  
Output  
Setpoint Accuracy  
1%  
Line Regulation V Min. - V Max., I  
Rated  
0.2% V  
Efficiency vs. Load (48V Input)  
in  
in  
out  
out  
Load Regulation I  
Remote Sense Headroom  
Minimum Output Current  
Min. - I  
Max., V Nom.  
0.2% V  
out  
out  
out in  
95  
90  
85  
80  
0.5 VDC  
10 %  
Dynamic Regulation, Loadstep  
Pk Deviation  
Settling Time  
25% I  
out  
4% V  
out  
500 ms  
10%  
75  
HES033ZE  
Voltage Trim Range  
70  
65  
60  
55  
50  
HES075ZG  
HES100ZE  
Short Circuit / Overcurrent Protection  
Current Limit Threshold Range, % of I  
OVP Trip Range  
Shutdown / Hiccup  
110 - 130%  
Rated  
out  
120 - 140% V Nom.  
out  
OVP Type  
Self Recovering  
General  
1
2
3
4
5
6
7
8
9
10  
X10 = LOAD %  
Turn-On Time  
10 ms  
Remote Shutdown  
Positive Or Negative Logic  
Remote Shutdown Reference  
Switching Frequency 2.5 & 3.3, 5V Model  
Isolation  
V Negative  
200 kHz, 300 kHz (Respectively)  
in  
Notes  
MTBF predictions may vary slightly from model to model.  
Input - Output  
Input - Case  
Output - Case  
Temperature Coefficient  
Case Temperature  
1500 VDC  
1050 VDC  
500 VDC  
0.02%/°C  
Specifications typically at 25°C, normal line, and full load, unless  
otherwise stated.  
Soldering Conditions: I/O pins, 260°C, ten seconds; fully  
compatible with commercial wave-soldering equipment.  
Operating Range  
Storage Range  
-40 To +100°C  
-40 To +125°C  
105 To 115°C  
5 g, 10 - 55 Hz  
Thermal Shutdown Range  
Vibration, 3 Axes, 5 Min Each  
Safety: Agency approvals may vary from model to model. Please  
consult factory for specific model information.  
6
MTBF (Bellcore Tr-nwt-000332)  
1.8 X 10 hrs  
Safety  
Weight (Approx.)  
UL 1950, CSA 22.2-950, EN60950  
1.4 oz  
Units are water-washable and fully compatible with commercial spray  
or immersion post wave-solder washing equipment.  
REV. JUL 24, 2003  
Page 1 of 3  
HES DC/DC Series Data Sheet  
Half-Brick Converters  
INPUT VOLTAGE  
(VOLTS)  
INPUT VOLTAGE  
RANGE (VOLTS)  
MAXIMUM INPUT  
CURRENT (AMPS)*  
OUTPUT  
VOLTAGE (VOLTS)  
RATED OUTPUT  
CURRENT (AMPS)  
RIPPLE & NOISE  
pk-pk (mV)  
TYPICAL  
EFFICIENCY**  
MODEL  
HES075YD-A  
HES100YE-AT  
HES033ZE-A  
HES050ZG-A  
HES037ZD-A  
HES050ZE-AN  
HES075ZG-A  
HES050ZD-A  
HES066ZE-AT  
HES100ZG-A  
HES075ZD-A  
HES100ZE-A  
HES150ZG-A  
24  
24  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
18-36  
18-36  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
36-72  
5.5  
7.4  
2.5  
3.3  
3.3  
5
2.5  
3.3  
5
2.5  
3.3  
5
2.5  
3.3  
5
30  
30  
10  
10  
15  
15  
15  
20  
20  
20  
30  
30  
30  
30  
150  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
81%  
83%  
87%  
88%  
86%  
88%  
89%  
86%  
85%  
88%  
82%  
83%  
86%  
80%  
1.13  
1.62  
1.33  
1.69  
2.42  
1.77  
2.26  
3.23  
2.60  
3.33  
4.72  
2.20  
HES063ZC-A  
2.1  
NOTES:  
*
Maximum input current at minimum input voltage, maximum rated output power.  
** At nominal V , rated output.  
in  
MECHANICAL DRAWING  
Pin  
Function  
Thermal Impedance  
Tolerances  
Inches:  
.XX 0.020  
.XXX 0.010  
(Millimeters)  
.X 0.5  
.XX 0.25  
1
2
3
4
5
6
-V  
in  
Natural Convection  
100 LFM  
15.4 °C/W  
12.2 °C/W  
9.3 °C/W  
7.4 °C/W  
6.4 °C/W  
Case  
200 LFM  
On/Off  
300 LFM  
400 LFM  
+V  
-V  
-Sense  
in  
out  
Pin:  
0.002  
0.05  
7
8
9
Trim  
Note:  
(Dimensions as listed unless  
otherwise specified.)  
Thermal impedance data is  
dependent on many environmental  
factors. The exact thermal  
performance should be validated  
for specific application.  
+Sense  
+V  
out  
REV. JUL 24, 2003  
Page 2 of 3  
OPTIONS  
This page is offered as a reference. Consult factory for actual availability of options. When ordering  
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the  
model number. Ordering option examples are located below the options table.  
OPTION  
Negative Logic  
SUFFIX  
APPLICABLE SERIES  
REMARKS  
N
HAS, HBD, HBS, HES, HLS, HLD, LES,  
QBS, QES, QLS, TES, TQD  
TTL "Low" Turns Module ON  
TTL "High" Turns Module OFF  
Lucent-Compatible Trim  
T
HAS, HBD, HBS, HES, HLS, QBS, QES,  
QLS  
Trim  
1
2
3
IAS, LES  
Enable  
IAD, IAS, LES, SMS  
IAS, LES  
Trim and Enable  
Pin Length and Heatsink Options  
0.110" (2.8mm) Pin Length  
Standard Pin Length is 0.180" (4.6mm)  
8
9
All Leaded Models  
All Leaded Models  
0.150" (3.8mm) Pin Length  
0.24" (6.1mm) Horizontal Heatsink  
1H  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
0.24" (6.1mm) Vertical Heatsink  
0.45" (11.4mm) Horizontal Heatsink  
0.45" (11.4mm) Vertical Heatsink  
0.95" (24.1mm) Horizontal Heatsink  
0.95" (24.1mm) Vertical Heatsink  
1V  
2H  
2V  
3H  
3V  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Example Options:  
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.  
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.  
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president  
of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
REV. JUL 24, 2003  
Page 3 of 3  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY