LS4001-7RDDB2 [BEL]

AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE;
LS4001-7RDDB2
型号: LS4001-7RDDB2
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE

电源电路
文件: 总27页 (文件大小:598K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
100 Watt AC-DC Converters with PFC  
S Series  
Input voltage range from 85...264 V AC  
1 or 2 isolated outputs up to 48 V DC  
4 kV AC I/O electric strength test voltage  
Universal input voltage range  
Power factor >0.95, harmonics <IEC/EN 61000-3-2  
Input over- and undervoltage lock-out  
Efficient input filter and built-in surge and transient  
suppression circuitry  
Fully isolated outputs  
Outputs overload, open- and short-circuit proof  
No derating over entire operating temperature range  
Safety according to IEC/EN 60950  
LGA  
111  
4.4"  
3 U  
60  
168  
2.4"  
6.6"  
12 TE  
Summary  
The S 4000/S 5000 series of AC-DC converters represents  
a flexible range of power supplies for use in advanced elec-  
tronic systems. Features include full power factor correc-  
tion, high efficiency, high reliability, low output voltage noise  
and excellent dynamic response to load/line changes.  
agencies LGA (Germany) and UL (USA). The UL Mark for  
Canada has been officially recognized by regulatory au-  
thorities in provinces across Canada.  
The converter inputs are protected against surges and tran-  
sients occurring at the source lines. An input over- and  
undervoltage lock-out circuitry disables the outputs if the  
input voltage is outside the specified range. Inrush current  
limitation is included preventing circuit breakers and fuses  
from being damaged at switch-on.  
The case design allows operation at nominal load up to  
71°C in a free air ambient temperature. If forced cooling is  
provided, the ambient temperature may exceed 71°C but  
the case temperature must remain below 95°C under all  
conditions.  
A temperature sensor generates an inhibit signal which  
disables the outputs if the case temperature TC exceeds  
the limit. The outputs are automatically re-enabled when  
the temperature drops below the limit.  
All outputs are overload, open- and short-circuit proof and  
are protected against overvoltages by means of a built-in  
suppressor diode. The outputs can be inhibited by a logic  
signal applied to the connector pin 18 (i). If the inhibit func-  
tion is not used pin 18 must be connected to pin 14 to en-  
able the outputs.  
Various options are available to adapt the converters to in-  
dividual applications.  
The modules may either be plugged into 19" rack systems  
according to DIN 41494, or be chassis mounted.  
LED indicators display the status of the converter and allow  
visual monitoring of the system at any time.  
Full input to output, input to case, output to case and output  
to output isolation is provided. The modules are designed  
and built according to the international safety standards  
IEC/EN 60950 and have been approved by the safety  
Important:  
These products are intended to replace the LS 1000 and  
LS 2000 in order to comply with IEC/EN 61000-3-2.  
Table of Contents  
Page  
Page  
Summary .......................................................................... 1  
Type Survey and Key Data .............................................. 2  
Type Key .......................................................................... 2  
Functional Description...................................................... 3  
Electrical Input Data ......................................................... 4  
Electrical Output Data ...................................................... 6  
Auxiliary Functions ......................................................... 11  
Electromagnetic Compatibility (EMC) ............................ 15  
Immunity to Environmental Conditions........................... 17  
Mechanical Data ............................................................ 18  
Safety and Installation Instructions ................................ 19  
Description of Options.................................................... 22  
Accessories.................................................................... 27  
Edition 01/01.2001  
1/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Type Survey and Key Data  
Non standard input/output configuration or special custom adaptions are available on request. See also: Commercial Infor-  
mation: Inquiry Form for Customized Power Supply.  
Table 1: Type survey LS  
Output 1  
Output 2  
Input Voltage Range  
Ui min...Ui max  
Efficiency 1  
hmin  
Options  
Uo nom  
Io nom  
[A] 2  
Uo nom  
Io nom  
[A] 2  
[V DC]  
[V DC]  
85...255 V AC 6  
[%]  
5.1  
16.0  
8.0  
6.5  
LS 4001-7R  
LS 4301-7R  
LS 4501-7R  
LS 4601-7R  
77  
81  
83  
83  
-9  
E
D
V 5  
P
T
B1  
B2  
12.0  
15.0  
24.0  
4.2  
24.0 3  
30.0 3  
48.0 3  
4.0  
3.2  
2.0  
LS 5320-7R  
LS 5540-7R  
LS 5660-7R  
81  
81  
81  
12.0  
15.0  
24.0  
4.0  
3.2  
2.0  
12.0 4  
15.0 4  
24.0 4  
4.0  
3.2  
2.0  
LS 5320-7R  
LS 5540-7R  
LS 5660-7R  
81  
81  
81  
1 Efciency at Ui nom and Io nom  
.
3 Series connection of output 1 and 2, see: R-Function for differ-  
ent output configurations.  
2 If the output voltages are increased above Uo nom via R-input  
control, option P setting, remote sensing or option T, the output  
currents must be reduced accordingly so that Po nom is not ex-  
ceeded.  
4 Second output semi-regulated.  
5 Option V for LS 4000 types with 5 V outputs.  
6 For DC-input please ask your local Power-One partner.  
Type Key  
Type Key  
L S 5 5 40 -7 E R P D V T B1  
Input voltage range Ui: 85...255 V AC .............................. L  
Series ...............................................................................S  
Number of outputs (4 for single, 5 for double outputs) 4...5  
Single output units:  
Nominal voltage output 1 (main output), Uo1 nom  
5.1 V .................................................... 0, 1, 2  
12 V ............................................................. 3  
15 V ......................................................... 4, 5  
24 V ............................................................. 6  
other voltages .......................................... 7, 8  
Other specifications for single output modules ....... 01...99  
Symmetrical double output units:  
Nominal voltage output 1/output 2, Uo1/2 nom  
12 V/12 V 1 (24 V series conn.).................. 20  
15 V/15 V 1 (30 V series conn.).................. 40  
24 V/24 V 1 (48 V series conn.).................. 60  
other symmetrical voltages ................. 70...99  
Operational ambient temperature range TA:  
25...71°C .................................................. -7  
40...71°C .................................................. -9  
customer specific .................................. -0...-6  
Auxiliary functions and options:  
Inrush current limitation ...............................E  
Output voltage control input ........................ R 2  
Potentiometer (output voltage adjustment)..P 2  
Save data signal (D0...DD, to be specified) D 3  
ACFAIL signal (V2, V3)................................V 3, 4  
Current sharing ............................................ T  
Cooling plate standard case ......................B1  
Cooling plate for longe case 220 mm ........ B2  
1 External wiring of main and second output depending upon the desired output configuration (see: R-Function for different output con-  
figurations).  
2 Feature R excludes option P and vice versa.  
3 Option D excludes option V and vice versa.  
4 Option V available for LS 4000 types with 5V output.  
Edition 01/01.2001  
2/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Functional Description  
The input voltage is fed via an input fuse, an input lter, a  
rectier and an inrush current limiter to a single transistor  
boost converter. This converter provides a sinusoidal input  
current (IEC/EN 61000-3-2, class D equipment) and sour-  
ces a capacitor with a voltage of 360-370 V DC. This ca-  
pacitor sources a single transistor forward converter.  
lter. The control logic senses the main output voltage Uo1  
and generates, with respect to the maximum admissible  
output currents, the control signal for the primary switching  
transistor.  
The second output of double output units is controlled by  
the main output, but has independent current limiting. If the  
main output is driven into current limitation, the second out-  
put voltage will fall as well and vice versa.  
Each output is powered by a separate secondary winding  
of the main transformer. The resultant voltages are rectied  
and their ripples smoothed by a power choke and an output  
P
03001  
16  
18  
20  
22  
12  
4
R
i
D/V  
T
S+  
Y
26  
28  
N
1
3
Y
Y
Vo+  
Ci  
+
6
4
8
Vo–  
10  
2
30  
32  
P~  
14 S–  
Y
24  
+
Fig. 1  
Block diagram of single output converters LS 4000  
P
03002  
16  
R
26  
28  
18 i  
Y
N~  
D
20  
22  
T
1
3
Y
Y
Ci  
+
12  
Vo1+  
4
14  
4
6
Vo1–  
Y
2
Vo2+  
30  
32  
P~  
8
10  
Vo2–  
Y
Y
24  
+
Fig. 2  
Block diagram of symmetrical double output converters LS 5000  
1 Transient suppressor (VDR)  
2 Inrush current limiter (NTC or Opt. E), -9 versions exclude the NTC  
3 Input fuse  
4 Hold-up capacitor  
Edition 01/01.2001  
3/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Electrical Input Data  
General Conditions  
TA = 25°C, unless TC is specied.  
Pin 18 connected to pin 14, Uo adjusted to Uo nom (option P); R input not connected.  
Sense line pins S+ and Sconnected to Vo+ and Vorespectively.  
Table 2: Input data  
Input  
LS  
Characteristics  
Conditions  
min  
85  
typ  
max  
255  
Unit  
Ui  
Operating Input voltage Io = 0...Io nom  
TC min...TC max  
V AC 3,4  
Ui nom Nominal Input voltage  
230  
0.55  
9.0  
1
Ii  
Input current  
Ui nom, Io nom  
Arms  
W
Pi0  
Pi inh  
Ri  
No-load input power  
Idle input power  
Input resistance  
Ui minUi max  
unit inhibited  
TC = 25°C  
10  
5
3.5  
480  
mΩ  
µF  
RNTC NTC resistance 2  
Ci Input capacitance  
3200 4000  
80  
100  
B
120  
Ui RFI Conducted input RFI  
Radiated input RFI  
EN 55022  
Ui nom, Io nom  
B
Ui abs Input voltage limits  
without damage  
400  
400  
400  
400  
V DC  
Vp  
1 With double output modules, both outputs loaded with Io nom  
.
2 Valid for -7 versions with NTC, (-9 versions exclude the NTC). Initial switch-on cycle. Subsequent switch-on/off cycles increase the in-  
rush current peak value.  
3 AC frequency range 47...63 Hz.  
4 For DC-input please ask your local Power-One partner.  
Input Fuse  
Reverse Polarity Protection  
A fuse mounted inside the converter protects the module  
against severe defects. (If operated from a DC-source this  
fuse may not fully protect the module when the input volt-  
age exceeds 200 V DC! In applications where the convert-  
ers operate at source voltages above 200 V DC an external  
fuseora circuit breaker at system level should be installed!)  
Should the input voltage to the unit be supplied from a DC  
source the built-in bridge rectier provides reverse polarity  
protection. (For DC-input operation, please consult your lo-  
cal Power-One partner.)  
Inrush Current Limitation  
The modules of the versions -7, incorporate an NTC resis-  
tor in the input circuitry which at initial turn on reduces  
the peak inrush current value by a factor of 5...10 to protect  
connectors and switching devices from damage. Subse-  
quent switch-on cycles within short periods will cause an  
increase of the peak inrush current value due to the warm-  
ing-up of the NTC resistor. See also: E option.  
Table 3: Fuse Specication  
Module  
Fuse type  
Fuse rating  
LS 1  
slow-blow  
SP T  
4 A, 250 V  
1 Fuse size 5 × 20 mm  
Input Under-/Overvoltage Lock-out  
If the input voltage remains below approx. 65 V AC or ex-  
ceeds approx. 280 V AC an internally generated inhibit sig-  
nal disables the output(s). When checking this function the  
absolute maximum input voltage rating Ui abs should be  
considered! Between Ui min and the undervoltage lock-out  
level the output voltage may be below the value defined in  
table: Output data (see: Technical Information: Measuring  
and Testing).  
Inrush Current Peak Value  
The inrush current peak value (initial switch-on cycle) can  
be determined by following calculation:  
Ui rms 2  
Iinr p = ––––––––––––––––  
(Rs ext + Ri + RNTC  
)
04001  
Rs ext Iinr p  
Ri  
RNTC  
Input Transient Protection  
A VDR together with the input fuse and a symmetrical input  
lter form an effective protection against high input tran-  
sient voltages.  
Ci  
Ui rms  
Fig. 3  
Equivalent circuit diagram for input impedance.  
Edition 01/01.2001  
4/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Input Inrush Current Characteristic  
Static Input current Characteristic  
li [Arms  
]
Iinr [A]  
04005  
04006  
3
2.5  
2
130  
100  
1.5  
1
Ui = 255 Vrms  
Ui = 115 Vrms  
Ui [V AC]  
300  
0.5  
50  
100  
150  
200  
250  
Fig. 6  
50  
1
Input current versus input voltage at Io nom  
Power Factor, Harmonics  
Power factor correction is achieved by controlling the input  
current waveform synchronously with the input voltage  
waveform. The power factor control is active under all oper-  
ating conditions.  
0
1
2
3 t [ms]  
Fig. 4  
Power Factor  
Theoretical input inrush current versus time at Ui 255 Vrms  
and 115 Vrms, Rext = 0.  
04004  
1
0.95  
Harmonic Currents  
0.9  
The harmonic distortion is well below the limits specified in  
IEC/EN 61000-3-2, class D.  
Ui = 230 V AC  
0.85  
Ui = 85 V AC  
I [mA/W]  
3.5  
0.8  
0.75  
0.7  
04042  
i
3.0  
Limit class D according  
to IEC/EN 61000-3-2  
0.2  
0.4  
0.6  
0.8  
1
Io/Io nom  
0
2.5  
Fig. 7  
2.0  
1.5  
1.0  
0.5  
Power factor versus output current at Ui 230 V AC and  
85 V AC.  
Harm.  
0
3
5
7
9
11  
13 15  
17 19  
Fig. 5  
Harmonic currents at the input, IEC/EN 61000-3-2,  
class D. Ui = Ui nom, Io = Io nom  
.
Edition 01/01.2001  
5/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Electrical Output Data  
General Conditions  
TA = 25°C, unless TC is specied.  
Pin 18 (i) connected to pin 14 (S/Vo1), Uo adjusted to Uo nom (option P), R input not connected.  
Sense line pins 12 (S+) and 14 (S) connected to pins 4 (Vo1+) and 8 (Vo1) respectively.  
Table 4a: Output data single output modules  
Output  
LS 4001  
5.1 V  
LS 4301  
12.0 V  
LS 4501  
15.0 V  
LS 4601  
24.0 V  
Characteristics  
Conditions  
min typ max min typ max min typ max min typ max Unit  
Uo  
Output voltage  
Ui nom, Io nom  
5.07  
5.13 11.93  
12.07 14.91  
15.09 23.86  
24.14  
V
Uop  
Overvoltage protection  
(supressor diode)  
7.6  
21  
26.5  
6.5  
43.5  
4.2  
Io nom Output current 1  
Ui min...Ui max  
TC min...TC max  
16.0  
8.0  
A
IoL  
uo  
Output current limit 2  
Ui min...Ui max  
16.2  
8.2  
6.7  
4.4  
5
Output Low frequency Ui nom, Io nom  
2
2
5
2
5
2
5
mVpp  
voltage  
noise  
IEC/EN 61204  
BW = 20 MHz  
Switching freq.  
Total  
15  
50  
40  
40  
40  
DUo U Static line regulation  
Ui min...Ui nom  
Ui nom...Ui max  
Io nom  
,
,
±5  
±12  
±15  
±24 mV  
DUo I Static load regulation  
Ui nom, Io =  
(0.1...1) Io nom  
20  
24  
30  
48  
3
uo d  
Dynamic Voltage  
Ui nom, Io =  
±170  
±150  
±150  
±100  
load  
deviation  
I
o nom 1/  
2
Io nom  
regulat.  
IEC/EN 61204  
3
t d  
Recovery time  
0.3  
0.4  
0.4  
0.3  
1.5  
ms  
aUo  
Temperature coefficient Ui min...Ui max  
of output voltage 4  
0...Io nom  
0.5  
-1.5  
-1.5  
mV/K  
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-  
rents should be reduced accordingly so that Po nom is not exceeded.  
2 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.  
3 See: Typical dynamic load regulation of Uo1 and Uo2.  
4 Negative temperature coefcient (0...3 mV/cell and K) available on request.  
5 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-  
tion: Measuring and Testing)  
Edition 01/01.2001  
6/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Table 4b: Output data double output modules  
Output  
LS 5320  
24 V (2 × 12 V)  
LS 5540  
30 V (2 × 15 V)  
LS 5660  
48 V (2 × 24 V)  
(Outputs connected in Series)  
Characteristics  
Conditions  
min  
typ  
24.0  
38  
max  
min  
typ  
30.0  
48  
max  
min  
typ  
48.0  
74  
max  
Unit  
V
Uo  
Output voltage 2  
Ui nom, Io nom  
Uop  
Overvoltage protection  
(supressor diode)  
Io nom Output current 1  
Ui min...Ui max  
TC min...TC max  
4.0  
3.2  
2.0  
A
IoL  
uo  
Output current limit 4  
Ui min...Ui max  
4.2  
3.4  
2.1  
7
Output Low frequency Ui nom, Io nom  
3
3
5
mVpp  
voltage  
noise 3  
IEC/EN 61204  
BW = 20 MHz  
Switching freq.  
Total  
15  
15  
20  
100  
100  
150  
DUo U Static line regulation  
Ui min...Ui max  
Io nom  
±12  
±15  
±24  
mV  
DUo I Static load regulation  
Ui nom, Io =  
(0.1...1) Io nom  
40  
60  
96  
5
uo d  
Dynamic Voltage  
Ui nom, Io =  
±250  
±200  
±150  
load  
deviation  
I
o nom 1/  
2
Io nom  
regulat.  
IEC/EN 61204  
5
t d  
Recovery time  
0.3  
0.3  
0.3  
ms  
aUo  
Temperature coefficient Ui min...Ui max  
of output voltage 6  
0...Io nom  
2.2  
2.2  
2.6  
mV/K  
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-  
rents should be reduced accordingly so that Po nom is not exceeded.  
2 Series connection for Uo nom = 24 V, 30 V or 48 V, see: R-Function for different output configurations.  
3 Shortest possible wiring for series connection at the connector.  
4 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.  
5 See: Typical dynamic load regulation of Uo1 and Uo2.  
6 Negative temperature coefcient (0...-3 mV/cell and K) available on request.  
7 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-  
tion: Measuring and Testing)  
Edition 01/01.2001  
7/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Table 4c: Output data double output modules  
Output  
LS 5320  
12 V/12 V  
LS 5540  
15 V/15 V  
(Outputs independently loaded) 1  
Characteristics  
Conditions  
Output 1  
Output 2  
Output 1  
Output 2  
min typ max min typ max min typ max min typ max Unit  
2
Uo  
Output voltage  
Ui nom, Io nom  
11.93  
12.07 11.82  
12.18 14.91  
15.09 14.78  
15.23  
V
A
Uop  
Overvoltage protection  
(supressor diode)  
19  
19  
24  
24  
Io nom Output current 3  
Ui min...Ui max  
TC min...TC max  
4.0  
4.0  
3.2  
3.2  
IoL  
uo  
Output current limit 4  
Ui min...Ui max  
4.2  
4.2  
3.4  
3.4  
8
Output Low frequency Ui nom, Io nom  
3
3
3
3
mV  
pp  
voltage  
noise  
IEC/EN 61204  
BW = 20 MHz  
Switching freq.  
Total  
12  
80  
12  
40  
10  
10  
40  
100  
DUo U Static line regulation  
Ui min...Ui nom  
Ui nom...Ui max  
Io nom  
±12  
±12  
±15  
±15 mV  
5
5
DUo I Static load regulation  
Ui nom, Io =  
(0.1...1) Io nom  
48  
60  
5
6
uo d  
Dynamic Voltage  
Ui nom, Io =  
±100  
±100  
load  
deviation  
I
o nom 1/  
2
Io nom  
regulat.  
IEC/EN 61204  
6
t d  
Recovery time  
0.3  
0.3  
ms  
aUo  
Temperature coefficient Ui min...Ui max  
of output voltage 7  
0...Io nom  
1.5  
1.5  
mV/K  
Table 4d: Output data double output modules  
Output  
LS 5660  
24 V/24 V  
1 Depending upon the desired out-  
put configuration the wiring should  
be made as shown in: R-Function  
for different output configurations.  
2 Same conditions for both outputs.  
3 If the control voltages are in-  
creased above Uo nom via R-input  
control, option Psetting, remote  
sensing or option T, the output  
currentsshould be reduced ac-  
cordingly so that Po nom is not ex-  
ceeded.  
(Outputs independently loaded) 1  
Characteristics  
Conditions  
Output 1  
Output 2  
min typ max min typ max Unit  
2
Uo  
Output voltage  
Ui nom, Io nom  
23.86  
24.14 23.64  
24.36  
V
A
Uop  
Overvoltage protection  
(supressor diode)  
37  
37  
Io nom Output current 3  
Ui min...Ui max  
TC min...TC max  
2.0  
2.0  
IoL  
uo  
Output current limit 4  
Ui min...Ui max  
2.1  
2.1  
4 See: Output Voltage Regulation of  
Single or Double Output Modules  
with Outputs 1 and 2 Connected  
in Series.  
8
Output Low frequency Ui nom, Io nom  
3
3
mVpp  
voltage  
noise  
IEC/EN 61204  
BW = 20 MHz  
Switching freq.  
Total  
10  
10  
40  
5 Condition for specified output.  
Other output loaded with constant  
current Io = Io nom. See: Output  
voltage regulation of double out-  
put units.  
100  
DUo U Static line regulation  
Ui min...Ui nom  
Ui nom...Ui max  
Io nom  
,
,
±24  
±24 mV  
6 See: Typical dynamic load regula-  
5
DUo I Static load regulation  
Ui nom, Io =  
(0.1...1) Io nom  
96  
5
tion of Uo1 and Uo2  
.
7 Negative temperature coefficient  
(0....3 mV/cell and K) available  
on request.  
6
uo d  
Dynamic Voltage  
Ui nom, Io =  
±80  
load  
deviation  
I
o nom 1/  
2
Io nom  
regulat.  
IEC/EN 61204  
8 Measured according to IEC/EN  
61204 sub clause 3.10 with a  
probe acc. to annex A of the same  
standards.  
6
t d  
Recovery time  
0.3  
ms  
aUo  
Temperature coefficient Ui min...Ui max  
of output voltage 7  
0...Io nom  
0.5  
mV/K  
Edition 01/01.2001  
8/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Thermal Considerations  
Parallel or Series Connection of Units  
If a converter is located in free, quasi-stationary air (con-  
vection cooling) at the indicated maximum ambient tem-  
perature TA max (see table: Temperature specifications) and  
is operated at its nominal input voltage and output power,  
the temperature measured at the Measuring point of case  
temperature TC (see: Mechanical Data) will approach the  
indicated value TC max after the warm-up phase. However,  
the relationship between TA and TC depends heavily on the  
conditions of operation and integration into a system. The  
thermal conditions are influenced by input voltage, output  
current, airflow and temperature of surrounding compo-  
Single or double output units with equal nominal output volt-  
age can be connected in parallel without any precautions  
using option T.  
With option T (current sharing), all units share the current  
approximately equally.  
Single output units and/or main and second outputs of dou-  
ble output units can be connected in series with any other  
(similar) output.  
Note:  
Parallel connection of double output units should always  
include both, main and second output to maintain good  
regulation of both outputs.  
nents and surfaces. TA max is therefore, contrary to TC max  
,
an indicative value only.  
Not more than 5 units should be connected in parallel.  
Series connection of second outputs without involving  
their main outputs should be avoided as regulation may  
be poor.  
Caution: The installer must ensure that under all operat-  
ing conditions TC remains within the limits stated in the  
table: Temperature specifications.  
The maximum output current is limited by the output with  
the lowest current limitation if several outputs are con-  
nected in series.  
Notes: Sufficient forced cooling or an additional heat sink  
allows TA to be higher than 71°C (e.g. 85°C) if TC max is not  
exceeded.  
For -7 or -9 units at an ambient temperature TA of 85°C with  
only convection cooling, the maximum permissible current  
for each output is approx. 40% of its nominal value as per  
figure.  
Output Voltage Regulation of Single or Double Output  
Modules with Outputs 1 and 2 Connected in Series  
Uo  
Uo nom  
05001  
Io/Io nom  
0.98  
Forced cooling  
1.0  
0.9  
0.8  
0.7  
Convection cooling  
0.5  
0.6  
Io1  
TC max  
0.5  
IoL  
0.4  
0.3  
0.2  
0.1  
Io  
Io nom  
0
0.5  
1.0  
0
Fig. 9  
o1 vs. Io1 (typ.) of single output units  
T [°C]  
A
T
50  
60  
70  
80  
90  
100  
A min  
U
Fig. 8  
Output current derating versus temperature for -7 and -9  
units.  
Output Voltage Regulation of Double Output Modules  
Output 1 is under normal conditions regulated to Uo1 nom  
,
Thermal Protection  
independent of the output currents.  
A temperature sensor generates an internal inhibit signal  
which disables the outputs if the case temperature exceeds  
TC max. The outputs are automatically re-enabled if the tem-  
perature drops below this limit.  
Uo2 is dependent upon the load distribution. If both outputs  
are loaded with more than 10% of Io nom, the deviation of  
Uo2 remains within ±5% of the value of Uo1. The following 3  
gures show the regulation with varying load distribution. If  
Io1 = Io2 or the two outputs are connected in series, the de-  
viation of Uo2 remains within ±1% of the value of Uo1 pro-  
vided that a total load of more than 10% of Io nom is applied.  
It is recommended that continuous operation under simul-  
taneous extreme worst case conditions of the following  
three parameters be avoided: Minimum input voltage,  
maximum output power and maximum temperature.  
Two outputs of a single S 5000 module connected in paral-  
lel will behave like the output of a S 4000 module; the paral-  
leled output is fully regulated. No precautions are neces-  
sary in using the R-input and the test sockets.  
Output Protection  
Each output is protected against overvoltage which could  
occur due to a failure of the control circuit by means of a  
voltage suppressor diode which, under worst case condi-  
tions, may become a short circuit. The suppressor diodes  
are not designed to withstand externally applied over-  
voltages. Overload at any of the two outputs will cause a  
shut-down of both outputs. A red LED indicates the over-  
load condition.  
Edition 01/01.2001  
9/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
[V] Uo2  
Dynamic Load Regulation  
Uo1  
05083  
05005  
13  
Io1 =100%  
Io1 = 50%  
Io1 = 10%  
Uo1d  
Ur  
Ur  
12.5  
12.0  
11.5  
11  
Uo1d  
td  
td  
t
Uo2  
Uo2d  
10.5  
0.4  
0.6  
0.8  
0
0.2  
1
Io2/Io2 nom  
t
t
Io1/Io1 nom  
Io2/Io2 nom  
Fig. 10  
1
LS 5320: DUo2 (typ.) vs. Io2 with different Io1.  
0.5  
<10 µs  
<10 µs  
[V] Uo2  
05084  
0
16.5  
Io1 = 100%  
Io1  
Io1  
Fig. 14  
=
=
50%  
10%  
16  
15.5  
15  
Typical dynamic load regulation of Uo1 and Uo2.  
Hold-up Time versus Output Power  
time [ms]  
180  
05013  
14.5  
14  
160  
140  
120  
100  
80  
13.5  
0
0.2  
0.4  
0.6  
0.8  
1
Io2/Io2 nom  
Fig. 11  
LS 5540: DUo2 (typ.) vs. Io2 with different Io1.  
60  
[V] Uo2  
05085  
40  
27  
Io1 = 100%  
20  
Io1  
Io1  
=
=
50%  
10%  
26  
25  
24  
23  
22  
21  
0
0
0.2  
0.4  
0.6  
0.8  
1
Io /Io nom  
Fig. 15  
Hold-up time th versus output power.  
Efciency versus Load  
Efficiency  
0.90  
05014  
0.4  
0
0.2  
0.6  
0.8  
1
Io2/Io2 nom  
0.80  
Fig. 12  
Ui = 230 V AC  
Ui 85 V AC  
0.70  
0.60  
0.50  
0.40  
0.30  
LS 5660: DUo2 (typ.) vs. Io2 with different Io1.  
=
Switching Frequency versus Load  
Frequency [kHz]  
05008  
80  
70  
60  
0
0.2  
0.4  
0.6  
0.8  
1
Io/Io nom  
Fig. 16  
Efciency versus load at Ui; 230 V AC and 85 V AC  
50  
40  
30  
20  
10  
0
0.2  
0.4  
0.6  
0.8  
1
1.2  
load [Io/Io nom  
0
]
Fig. 13  
Switching frequency versus load. (The boost converter at  
the input stage has a xed frequency of 100 kHz)  
Edition 01/01.2001  
10/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Auxiliary Functions  
Sense Lines  
i Inhibit for Remote On and Off  
(Only for single output units 5.1 V, 12 V, 15 V, 24 V)  
Note: With open i input: Output is disabled (Uo = off).  
The outputs of the module may be enabled or disabled by  
means of a logic signal (TTL, CMOS, etc.) applied between  
the inhibit input i and the negative pin of output 1 (Vo1). In  
systems with several units, this feature can be used, for ex-  
ample, to control the activation sequence of the converters.  
If the inhibit function is not required, connect the inhibit pin  
18 to pin 14 to enable the outputs (active low logic, fail  
safe). For output response refer to: Hold-up Time and Out-  
put Response.  
This feature enables for compensation of voltage drops  
across the connector contacts and if necessary, across the  
load lines. If the sense lines are connected at the load  
rather than directly at the connector, the user should ensure  
that Uo max (between Vo1+ and Vo1) is not exceeded. We  
recommend connecting the sense lines directly at the fe-  
male connector.  
For further information, please refer to: Application Notes .  
To ensure correct operation, both sense lines (S+ and S)  
should be connected to their respective power outputs  
(Vo1+ and Vo1) and the voltage difference between any  
sense line and its respective power output pin (as meas-  
ured on the connector) should not exceed the following val-  
ues:  
06031  
Vo+  
i
Vi+  
Iinh  
Uinh  
Table 6: Maximum Voltage compensation allowed using  
sense lines  
Vo–  
Vi–  
Output  
voltage  
Total voltage difference Voltage difference  
Fig. 17  
Definition of Uinh and Iinh  
between sense lines and  
their respective outputs  
between  
Voand S–  
.
5.1 V  
<0.5 V  
<1.0 V  
<0.25 V  
<0.25 V  
Iinh [mA]  
Uinh = 2.4 V  
U
inh = 0.8 V  
12 V, 15 V  
2.0  
1.6  
1.2  
If the output voltages are increased above Uo nom via R-in-  
put control, option P setting, remote sensing or option T, the  
output currents must be reduced accordingly so that  
Po nom is not exceeded.  
0.8  
0.4  
Important: The output terminals Vo1+ and Vo1must  
always be connected to the load before connecting the  
sense lines S+ and S, otherwise the unit will be dam-  
aged.  
Uo = on  
Uo = off  
0
0.4  
0.8  
Uinh [V]  
50  
30  
10  
0
10  
30  
50  
Fig. 18  
Typical inhibit current Iinh versus inhibit voltage Uinh  
Table 5: Inhibit characteristics  
Characteristic  
Conditions  
min typ max Unit  
Uinh Inhibit Uo = on Ui minUi max 50  
0.8  
50  
V
voltage  
Uo = off  
2.4  
Iinh Inhibit current  
Uinh = 0  
400 µA  
tr  
tf  
Rise time  
30  
depending on Io  
ms  
Fall time  
06001  
Uo/Uo nom  
1
0.1  
0
t
tf  
tr  
Inhibit  
1
t
0
Fig. 19  
Output response as a function of inhibit control  
Edition 01/01.2001  
11/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Programmable Output Voltage (R-Function)  
As a standard feature, the modules offer an adjustable out-  
put voltage, identied by letter R in the type designation.  
The control input R (pin 16) accepts either a control voltage  
Uext or a resistor Rext to adjust the desired output voltage.  
When not connected, the control input automatically sets  
If the output voltages are increased above Uo nom via R-  
input control, option P setting, remote sensing or option  
T, the output current(s) should be reduced accordingly so  
that Po nom is not exceeded.  
The R-input (as well as option P) is related to the main  
output.  
the output voltage to Uo nom  
.
a) Adjustment by means of an external control voltage Uext  
between pin 16 (R) and pin 14:  
With double output units the second output follows the  
value of the controlled main output. Resistor values as  
indicated for the single output units should be used.  
The control voltage range is 0...2.75 V DC and allows an  
output voltage adjustment in the range of approximately  
For correct output voltage adjustment of double output  
units the external wiring of the outputs should be accord-  
ing to g.: R-Function for different output configuration  
depending upon the desired output conguration.  
0...110% Uo nom  
U
.
Uext = –––o––– • 2.5 V (approximate formula)  
Uo nom  
b) Adjustment by means of an external resistor:  
In case of parallel connection the output voltages should  
Depending upon the value of the required output voltage  
the resistor shall be connected  
be individually set within a tolerance of 1...2%.  
06003  
Vo1+  
R
N
either: Between pin 16 and pin 14 (Uo < Uo nom) to  
achieve an output voltage adjustment range of approxi-  
mately 0...100% Uo nom  
+
16  
14  
Module  
Module  
Uext  
S–  
or: Between pin 16 and pin 12 (Uo > Uo nom) to achieve  
an output voltage adjustment range of approximately  
Vo1–  
P
N
100...110% Uo nom  
.
Vo1+  
Warning:  
S+  
R
12  
Uext shall never exceed 2.75 V DC.  
R'ext  
Rext  
16  
14  
The value of R'ext shall never be less than the lowest  
value as indicated in table R'ext (for U0 >U0 nom) to avoid  
damage to the unit!  
S–  
Vo1–  
P
Remarks:  
Fig. 20  
Output voltage control for single output units LS 4000 by  
means of the R input  
The R-Function excludes option P (output voltage ad-  
justment by potentiometer).  
Table 7a: Rext for Uo < Uo nom; approximative values (Ui nom, Io nom, series E 96 resistors); R'ext = ∞  
Uo nom = 5.1 V  
Uo (V) Rext [k]  
Uo nom = 12 V  
Uo [V] 1  
Uo nom = 15 V  
Uo [V] 1  
Uo nom = 24 V  
Uo [V] 1  
Rext [k]  
Rext [k]  
Rext [k]  
0.806  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
4.5  
5.0  
0.432  
0.976  
1.65  
2.61  
3.83  
5.76  
8.66  
14.7  
30.1  
200  
2
3
4
5
6
7
8
9
10  
11  
4
6
8
10  
12  
14  
16  
18  
20  
22  
0.806  
1.33  
2
2.87  
4.02  
5.62  
8.06  
12.1  
20  
2
4
6
8
9
10  
11  
12  
13  
14  
4
8
0.619  
1.47  
2.67  
4.53  
6.04  
8.06  
11  
16.2  
26.1  
56.2  
4
6
8
10  
12  
14  
16  
18  
20  
22  
8
12  
16  
20  
24  
28  
32  
36  
40  
44  
1.33  
2
2.87  
4.02  
5.62  
8.06  
12.1  
20  
44.2  
12  
16  
18  
20  
22  
24  
26  
28  
42.2  
Table 7b: Rext for Uo > Uo nom; approximative values (Ui nom, Io nom, series E 96 resistors); Rext = ∞  
Uo nom = 5.1 V  
Uo [V] R'ext [k]  
5.15 432  
Uo nom = 12 V  
Uo [V] 1  
Uo nom = 15 V  
Uo [V] 1  
Uo nom = 24 V  
R'ext [k]  
R'ext [k]  
Uo [V] 1  
R'ext [k]  
12.1  
12.2  
12.3  
12.4  
12.5  
12.6  
12.7  
12.8  
13.0  
13.2  
24.2  
24.4  
24.6  
24.8  
25.0  
25.2  
25.4  
25.6  
26.0  
26.4  
1820  
931  
619  
475  
383  
316  
274  
243  
196  
169  
15.2  
15.4  
15.6  
15.8  
16.0  
16.2  
16.4  
16.5  
30.4  
30.8  
31.2  
31.6  
32.0  
32.4  
32.8  
33.0  
1500  
768  
523  
392  
316  
267  
232  
221  
24.25  
24.5  
24.75  
25.0  
25.25  
25.5  
25.75  
26.0  
48.5  
49.0  
49.5  
50.0  
50.5  
51.0  
51.5  
52.0  
52.5  
52.8  
3320  
1690  
1130  
845  
698  
590  
511  
442  
402  
383  
5.2  
5.25  
5.3  
215  
147  
110  
5.35  
5.4  
88.7  
75  
5.45  
5.5  
64.9  
57.6  
26.25  
26.4  
1 First column: single output units or double output units with separated outputs, second column: outputs in series connection  
Edition 01/01.2001  
12/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
R-Function for different output configurations  
06004  
06005  
+
Vo2+  
+
4
Vo2+  
Vo2+  
Vo2–  
Vo2–  
Vo1+  
Vo1–  
4
6
Vo2+  
Vo2–  
Vo2–  
Vo1+  
Vo1–  
6
8
12 V  
15 V  
24 V  
1
Uo1  
24 V  
30 V  
48 V  
8
1
Uo1  
10  
12  
14  
10  
12  
2
14  
16  
Rext R'ext  
Rext R'ext  
16  
R
R
Fig. 21a  
Fig. 21b  
LS 5000 with H15 connector. R-input for output voltage  
control. Wiring for output voltage 24 V or 30 V or 48 V with  
main and second output connected in series.  
LS 5000 with H15 connector. R-input for output voltage  
control. Wiring for output voltage 12 V or 15 V or 24 V  
with main and second output connected in parallel.  
06006  
06007  
+24/+30/+48 V  
0 V  
Vo2+  
Vo2+  
Vo2–  
Vo2–  
Vo1+  
Vo1–  
4
6
Vo2+  
Vo2+  
Vo2–  
Vo2–  
Vo1+  
Vo1–  
+
4
6
1
1
Uo2  
12/15/24 V  
8
8
Uo2  
+12/+15/+24 V  
0 V  
Uo1  
10  
12  
+
10  
12  
2
1
1
Uo1  
+12/+15/+24 V  
+
14  
16  
14  
16  
Rext R'ext  
Rext R'ext  
R
R
Fig. 21c  
Fig. 21d  
LS 5000 with H15 connector. R-input for output voltage  
control. Wiring of main and second output for two output  
voltages Uo1 and Uo2: +12 V and +24 V or +15 V and  
+30 V or +24 V and +48 V.  
LS 5000 with H15 connector. R-input for output voltage  
control. Wiring of main and second output for two sym-  
metrical output voltages Uo1 and Uo2: ±12 V or ±15 V or  
±24 V.  
1 A ceramic multilayer capacitor connected across the load re-  
duces ripple and spikes.  
06008  
+
Vo2+  
Vo2+  
Vo2–  
Vo2–  
Vo1+  
Vo1–  
4
6
2 Shortest possible wiring for series connection at the female con-  
nector  
12 V  
15 V  
24 V  
1
1
Uo2  
8
+
10  
12  
12 V  
15 V  
24 V  
Uo1  
Remarks:  
14  
16  
Rext R'ext  
Double output units tted with H15 connectors have the  
output pins of the second output, pins 4/6 and 8/10, inter-  
nally paralleled.  
R
It is recommended that pins 4/6 and 8/10 be directly paral-  
leled at the female connector as well to reduce the voltage  
drop across the connector.  
Fig. 21e  
LS 5000 with H15 connector. R-input for output voltage  
control. Wiring of main and second output for two output  
voltages Uo1 and Uo2: 12 V/12 V or 15 V/15 V or  
24 V/24 V, the outputs are galvanically isolated.  
Please note: Uo2 varies depending upon its own load and  
the load on output 1.  
Edition 01/01.2001  
13/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Display Status of LEDs  
06002  
Uo1 > 0.95...0.98Uo1 adj  
Fig. 22  
OK  
i
LEDs "OK", "i" and "Io L"status versus input voltage  
Conditions: Io £ Io nom, TC £ TC max, Uinh £ 0.8 V  
i uv = undervoltage lock-out, Ui ov = overvoltage lock-out  
Io L  
Ui  
U
Ui uv Ui min  
Ui max Ui ov Ui abs  
Uo1 > 0.95...0.98Uo1 adj  
Uo1 < 0.95...0.98Uo1 adj  
OK  
Io L  
LEDs "OK" and "Io L"status versus output current  
Conditions: Ui min...Ui max, TC £ TC max, Uinh £ 0.8 V  
Io  
Io nom  
IoL  
i
i
LED "i"versus case temperature  
Conditions: Ui min...Ui max, Io £ Io nom, Uinh £ 0.8 V  
TC  
TC max  
Uinh threshold  
TPTC threshold  
LED "i"versus Uinh  
Conditions: Ui min...Ui max, Io £ Io nom, TC £ TC max  
Ui inh  
+0.8 V  
+2.4 V  
+50 V  
-50 V  
LED off  
LED Status undefined  
LED on  
Test Sockets (Main output only )  
Battery Charging/Temperature Sensor  
Test sockets for measuring the output voltage Uo1 are lo-  
cated at the front of the module. The positive test socket is  
protected by a series resistor (see: Functional Description,  
block diagrams). The voltage measured at the test sockets  
is approximately 30 mV lower than the value measured at  
the output terminals.  
The LS are intended for lead acid battery charger applica-  
tions. For an optimum battery charging and life expectancy  
of the battery an external temperature sensor may be con-  
nected to the R-input. The sensor is mounted as close as  
possible to the battery pole and adjusts the output voltage  
of the LS unit according to the temperature of the battery  
(which is related to the load of the battery and the ambient  
temperature).  
In case of double output units externally connected in se-  
ries for Uo = 24 V, 30 V or 48 V the monitored output volt-  
age is 12 V, 15 V or 24 V respectively.  
Depending on the cell voltage and the temperature coeffi-  
cient of the battery, different sensor types are available.  
For more information please ask Power-One.  
Cell voltage [V]  
2.40  
06123  
Uo max  
2.35  
2.30  
Uz = 2.27 V, 3.5 mV/K  
2.25  
2.20  
Uz = 2.23 V, 3.5 mV/K  
Uo nom  
2.15  
[°C]  
20 25 30 35 40 45 50  
2.10  
0
5
10 15  
Fig. 17  
Dependance of output voltage vs. temperature for defined  
temperature coefficient.  
Edition 01/01.2001  
14/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Electromagnetic Compatibility (EMC)  
A metal oxide VDR together with an input fuse and an input  
filter form an effective protection against high input tran-  
sient voltages which typically occur in most installations.  
The S series has been successfully tested to the following  
specifications:  
Electromagnetic Immunity  
Table 8: Immunity type tests  
Phenomenon  
Standard 1  
Level  
Coupling  
mode 2  
Value  
applied  
Waveform  
Source  
imped.  
Test  
procedure  
In  
Per-  
oper. form. 3  
4
Voltage surge  
IEC 60571-1  
i/c, +i/i  
800 Vp  
1500 Vp  
3000 Vp  
4000 Vp  
7000 Vp  
1.5 Ubatt  
100 µs  
50 µs  
5 µs  
100 Ω  
1 pos. and 1 neg.  
voltage surge per  
coupling mode  
yes  
1 µs  
100 ns  
1 s  
4
Supply related  
surge  
RIA 12  
B
+i/i  
0.2 Ω  
5 Ω  
1 positive  
surge  
yes  
4
Direct transient  
C
D
E
F
G
H
J
+i/c, i/c  
960 Vp  
1800 Vp  
3600 Vp  
4800 Vp  
8400 Vp  
1800 Vp  
3600 Vp  
4800 Vp  
8400 Vp  
10/100 µs  
5/50 µs  
5 pos. and 5 neg.  
impulses  
yes  
0.5/5 µs  
0.1/1 µs  
0.05/0.1 µs  
5/50 µs  
100 Ω  
Indirect coupled  
transient  
o/c, +o/c  
0.5/5 µs  
0.1/1 µs  
0.05/0.1 µs  
1/50 ns  
K
L
Electrostatic  
discharge  
(to case)  
IEC/EN  
61000-4-2  
4
contact discharge 8000 Vp  
330 Ω  
10 positive and  
10 negative  
discharges  
yes  
A
air discharge  
15000 Vp  
Electromagnetic IEC/EN  
3
4
antenna  
10 V/m  
AM 80%  
1 kHz  
n.a.  
801000 MHz  
yes  
yes  
A
A
field  
61000-4-3  
Electromagnetic ENV 50204  
field,  
pulse modulated  
50% duty cycle,  
200 Hz repetition  
frequency  
900 ±5 MHz  
Electrical fast  
transient/burst  
IEC/EN  
61000-4-4  
capacitive, o/c  
2000 Vp bursts of 5/50 ns 50 Ω  
1 min positive  
1 min negative  
transients per  
coupling mode  
yes  
A
A
2.5/5 kHz over  
15 ms; burst  
period: 300 ms  
i/c, +i/i  
direct  
4000 Vp  
Surge  
IEC/EN  
61000-4-5  
3
4
i/c  
+i/i  
2000 Vp  
2500 Vp  
1.2/50 µs  
12 Ω  
2 Ω  
5 pos. and 5 neg.  
surges per  
yes  
yes  
A
A
i/c, +i/i  
10/700 µs  
40 Ω  
150 Ω  
Conducted  
disturbances  
IEC/EN  
61000-4-6  
3
i, o, signal wires  
10 Vrms  
(140 dBµV)  
AM 80%  
1 kHz  
0.15...80 MHz  
1 Related and previous standards are referenced in: Technical Information: Standards.  
2 i = input, o = output, c = case.  
3 A = Normal operation, no deviation from specifications, B = Normal operation, temporary deviation from specs possible.  
4 Test in progress, please consult factory.  
Note: Previous standards are referenced in: Technical In-  
formation: Standards  
Edition 01/01.2001  
15/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Electromagnetic Emission  
[dBµV]  
90  
07063  
[dBµV/m]  
50  
07038  
A
80  
70  
60  
50  
40  
30  
20  
10  
0
A
B
40  
B
30  
20  
10  
[MHz]  
0
MHz  
Fig. 23  
Fig. 24  
Typical disturbance voltage (quasi-peak) at the input accord- Typical radiated electromagnetic field strength (quasi-  
ing to CISPR 11/22 and EN 55011/22, measured at  
i nom and Io nom  
peak) according to CISPR 11/22 and EN 55011/22, nor-  
malized to a distance of 10 m, measured at Ui nom and  
U
.
Io nom  
.
Edition 01/01.2001  
16/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Immunity to Environmental Conditions  
Table 9: Environment specifications  
Test method  
Standard  
Test conditions  
Status  
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
IEC/DIN IEC 60068-2-3  
MIL-STD-810D section 507.2 Relative humidity:  
Duration:  
Temperature:  
40 ±2 °C  
%
56 days  
Unit not  
operating  
93 +2/-3  
Shock  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-27  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
100 gn = 981 m/s2  
6 ms  
18 (3 each direction)  
Unit  
operating  
Bump  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-29  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
40 gn = 392 m/s2  
6 ms  
6000 (1000 each direction)  
Unit  
operating  
Vibration  
(sinusoidal)  
IEC/EN/DIN EN 60068-2-6  
Acceleration amplitude:  
0.35 mm (10...60 Hz)  
5 gn = 49 m/s2 (60...2000 Hz) operating  
10...2000 Hz  
Unit  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Fn  
Kb  
Vibration  
broad band  
random  
IEC 60068-2-64  
DIN 40046 part 23  
MIL-STD-810D section 514.3 Acceleration magnitude:  
Test duration:  
Acceleration spectral density: 0.05 gn2/Hz  
Unit  
operating  
Frequency band:  
5...500 Hz  
4.97 gn rms  
3 h (1 h each axis)  
(digital dontrol)  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
IEC/EN/DIN IEC 60068-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30°C)  
Unit not  
operating  
2 h per cycle  
40°C, 93% rel. humidity  
22 h per cycle  
3
Table 10: Temperature specications, values given are for an air pressure of 800...1200 hPa (800...1200 mbar)  
Temperature  
Standard -7  
Option -9  
Characteristics  
Conditions  
min  
25  
25  
40  
max  
71  
min  
40  
40  
55  
max  
71  
Unit  
TA Ambient temperature  
TC Case temperature  
TS Storage temperature  
Ui min...Ui max  
Io = 0...Io nom  
°C  
95  
95  
Not operational  
100  
100  
Table 11: MTBF  
Values at Specied  
Type  
Ground Benign  
Ground Fixed  
Ground Mobile  
Unit  
Case Temperature  
40°C  
40°C  
70°C  
50°C  
MTBF 1  
LS 4000/5000  
514'000  
88'000  
38'000  
35'000  
h
1 Calcualted in accordance with MIL-HDBK217F.  
Edition 01/01.2001  
17/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Mechanical Data  
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.  
European  
Projection  
7 TE  
5 TE  
3.27  
171.93 (DIN 41494)  
50  
M4  
Measuring point of  
case temperature T  
C
(+/)  
Test jacks  
Option P (U )  
o
to  
Option D (U  
)
Option D (U )  
ti  
LED i (red)  
LED OK (green)  
LED IoL (red)  
= Ø 3.5  
= Ø 4.1  
8
152  
8
30  
60  
Front plate  
Back plate  
Main face  
168.5 ±0.5  
Note:  
d 15 mm, recommended minimum distance to  
next part to ensure proper air circulation at full  
output power.  
free air locations: the module should be moun-  
ted with ns in vertical position to achieve a  
maximum air ow through the heat sink.  
Fig. 25  
Aluminium case S02 with heatsink, black finish and self  
cooling, weight: Approx. 1.25 kg  
7 TE  
3.27  
4 TE  
50  
5
158  
M 4  
Measuring point of  
case temperature TC  
5
47.2  
17.3  
133.4  
168 ±0.5  
171.93 (DIN 41494)  
Note: Long case with option B2, elon-  
gated by 60 mm for 220 mm rack depth,  
is available on request. (No LEDs, no  
test jacks.)  
Fig. 26  
Aluminium case S02 with option B1 (cooling plate), black  
finish and self cooling. Total weight: Approx. 1.15 kg  
Edition 01/01.2001  
18/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Safety and Installation Instructions  
Installation Instructions  
Connector Pin Allocation  
The S series AC-DC converters are components, intended  
exclusively for inclusion within other equipment by an in-  
dustrial assembly operation or by professional installers. In-  
stallation must strictly follow the national safety regulations  
in compliance with the enclosure, mounting, creepage,  
clearance, casualty, markings and segregation require-  
ments of the end-use application.  
The connector pin allocation table defines the electrical  
potentials and the physical pin positions on the H15 con-  
nector. Pin no. 24, the protective earth pin present on all LS  
AC-DC converters is leading, ensuring that it makes con-  
tact with the female connector first.  
10002  
Connection to the system shall be made via the female con-  
nector H15 (see: Accessories). Other installation methods  
may not meet the safety requirements.  
The AC-DC converters are provided with pin no. 24 ( ),  
which is reliably connected with their case. For safety rea-  
sons it is essential to connect this pin with the protective  
earth of the supply system.  
32  
4
Type H15  
Fig. 27  
An input fuse is built-in in the connection from pins no. 30  
and 32 (P ) of the unit. Since this fuse is designed to pro-  
tect the unit in case of an overcurrent and does not neces-  
sarily cover all customer needs, an external fuse suitable  
for the application and in compliance with the local require-  
ments might be necessary in the wiring to one or both input  
potentials, pins nos. 26 and 28 and/or nos. 30 and 32.  
View of modules male H15 connector  
Table 12: H15 Connector pin allocation  
Pin Connector type H 15  
No. LS 4000  
LS 5000  
Vo2+  
Vo2+  
Vo2–  
Vo2–  
Vo1+  
Vo1–  
R 1  
4
Vo1+  
Vo1+  
Vo1–  
Vo1–  
S+  
Output 1  
Output 1  
Output 2  
Output 2  
6
Important: Whenever the inhibit function is not in use,  
pin no. 18 (i) should be connected to pin no. 14 (S/Vo1)  
to enable the output(s).  
8
10  
12  
14  
16  
18  
20  
Do not open the modules, or guarantee will be invali-  
dated.  
Sense  
Output 1  
Output 1  
Control of Uo1  
Inhibit  
S–  
Sense  
Due to high current values, all LS units provide two inter-  
nally parallel connected contacts for certain paths (pins 4/6,  
8/10, 26/28 and 30/32, respectively). It is recommended to  
connect load and supply to both female connector pins of  
each path in order to keep the voltage drop across the con-  
nector pins to an absolute minimum and to not overstress  
the connector contacts if currents are higher than  
approx. 8 A. The connector contacts are rated 8 A over the  
whole temperature range.  
R 1  
Control of Uo1  
Inhibit  
i
i
D
Save data  
ACFAIL  
D
Save data  
V 3  
22  
T
Current sharing  
T
Current sharing  
Protective earth  
24 2  
26  
Protective earth  
Neutral  
N
N
P
P
N
N
P
P
Neutral  
Phase  
Make sure that there is sufficient air flow available for con-  
vection cooling. This should be verified by measuring the  
case temperature when the unit is installed and operated in  
the end-use application. The maximum specified case tem-  
perature TC max shall not be exceeded. See also: Thermal  
Considerations.  
28  
30  
Phase  
32  
1 Feature R excludes option P and vice versa  
2 Leading pin (pregrounding)  
3 Option D excludes option V and vice versa  
Check for hazardous voltages before altering any connec-  
tions.  
Ensure that a unit failure (e.g. by an internal short-circuit)  
does not result in a hazardous condition. See also: Safety  
of operator accessible output circuit.  
Protection Degree  
Condition: Female connector fitted to the unit.  
IP 30: All units except those with option P, and except  
those with option D or V with potentiometer.  
Cleaning Agents  
IP 20: All units fitted with option P, or with option D or V with  
potentiometer.  
In order to avoid possible damage, any penetration of  
cleaning fluids is to be prevented, since the power supplies  
are not hermetically sealed.  
Edition 01/01.2001  
19/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Standards and Approvals  
All AC-DC converters correspond to class I equipment.  
They are UL recognized according to UL 1950, UL recog-  
nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA  
approved to IEC/EN 60950 standards.  
The use in a pollution degree 2 environment  
The UL 1950 recognition limits the minimum input voltage  
to Ui = Ui min + 5 V AC = 90 V AC if the case temperature  
exceeds 90°C.  
The units have been evaluated for:  
Building in  
Basic insulation between input and case, based on 250 V  
AC and 400 V DC  
The AC-DC converters are subject to manufacturing sur-  
veillance in accordance with the above mentioned UL,  
CSA, EN and with ISO 9001 standards.  
Double or reinforced insulation between input and output,  
based on 250 V AC and 400 V DC  
Basic insulation between output and case based on  
200 V AC and DC  
Operational insulation between output and output  
Connecting the input to a primary or secondary circuit  
which is subject to a maximum transient rating of 2500 V  
(overvoltage category III based on a 110 V primary cir-  
cuit, overvoltage category II based on a 230 V primary  
circuit).  
Isolation  
The electric strength test is performed as factory test in ac-  
cordance with IEC/EN 60950 and UL 1950 and should not  
be repeated in the field. Power-One will not honour any  
guarantee claims resulting from electric strength field tests.  
Important: Testing by applying AC voltages will result in  
high and dangerous leakage currents flowing through  
the Y-capacitors (see fig.: Block diagram).  
Table 13: Isolation  
Characteristic  
Input to  
case  
Input to Output to Output to  
Unit  
output  
case  
output  
Electric  
strength  
test voltage  
Required according to  
IEC/EN 60950  
1.5  
2.1  
2.8  
2.0  
3.0 1  
kVrms  
4.2 1  
kV DC  
Actual factory test 1 s  
5.6 1  
1.4  
1.0  
0.14  
0.1  
AC test voltage equivalent  
to actual factory test  
4.0 1  
kVrms  
Insulation resistance at 500 V DC  
>300  
>300  
>300  
>100 2  
MΩ  
1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.  
2 Tested at 100 V DC.  
For creepage distances and clearances refer to: Technical Information: Safety.  
Leakage Currents in AC-DC operation  
Leakage currents flow due to internal leakage capacitance  
and RFI suppression Y-capacitors. The current values are  
proportional to the mains voltage and nearly proportional to  
the mains frequency and are specified at an input voltage of  
254 V (50 Hz) where phase, neutral and protective earth  
are correctly connected as required for class I equipment.  
Under test conditions the leakage current flows through a  
measuring instrument (MI) as described in fig.: Measuring  
instrument for earth leakage current tests, which takes into  
account impedance and sensitivity of a person touching  
unearthed accessible parts. The current value is calculated  
by dividing the measured voltage by 500 . If inputs of S-  
units are connected in parallel, their individual leakage cur-  
rents are added.  
1500 Ω  
MI  
500 Ω  
10062  
P
Vo+  
P
N
N
Vo–  
10 kΩ  
220 nF  
MI for  
earth  
leakage  
current  
22 nF  
V
Fig. 28  
Fig. 29  
Measuring instrument (MI) for earth leaking current tests  
according to IEC/EN 60950.  
Test set-up  
Edition 01/01.2001  
20/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
Table 14: Leakage currents  
Characteristic  
Class I  
Unit  
LS 4000...LS 5000  
Maximum earth  
leakage current  
Permissible according to IEC/EN 60950  
Specified value at 254 V, 50 Hz  
3.5  
mA  
0.82  
Safety of operator accessible output circuit  
If the output circuit of an AC-DC converter is operator ac-  
cessible, it shall be an SELV circuit according to the IEC/EN  
60950 related safety standards.  
to IEC/EN 60950 up to a configured output voltage (sum of  
nominal voltages if in series or +/configuration) of 36 V.  
However, it is the sole responsibility of the installer to as-  
sure the compliance with the relevant and applicable safety  
regulations. More information is given in: Technical Infor-  
mation: Safety.  
The following table shows a possible installation configura-  
tion, compliance with which causes the output circuit of an  
S series AC-DC converter to be an SELV circuit according  
Table 15: Safety concept leading to an SELV output circuit  
Conditions  
AC-DC converter  
Installation  
Result  
Nominal voltage  
Grade of insulation  
between input and output  
provided by the AC-DC converter  
Measures to achieve the resulting  
safety status of the output circuit  
Safety status of the AC-DC  
converter output circuit  
Mains  
Double or reinforced  
Earthed case 1 and installation  
SELV circuit  
250 V AC  
according to the applicable standards  
1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950.  
10021  
Fuse  
+
~
Mains  
AC-DC  
con-  
verter  
SELV  
Fig. 30  
Fuse  
~
Schematic safety concept. Use fuses and earth connec-  
tion as per Installation Instructions and table Safety con-  
cept leading to an SELV output circuit.  
Earth connection  
Description of Options  
Table 16: Survey of options  
Option  
9  
Function of option  
Characteristic  
Extended operational ambient temperature range  
Electronic inrush current limitation circuitry  
Potentiometer for fine adjustment of output voltage  
Input and/or output undervoltage monitoring circuitry  
Input and/or output undervoltage monitoring circuitry  
Current sharing  
TA = 40...71°C  
E
Active inrush current limitation  
P 1  
Adjustment range +10/-60% of Uo nom, excludes R input  
Safe data signal output (D0...DD)  
D 2  
V 2 3  
T
ACFAIL signal according to VME specifications (V0, V2, V3)  
Interconnect T-pins if paralleling outputs (5 units max.)  
B1, B2  
Cooling plate  
Replaces standard heat sink, allowing direct chassis-mounting  
1 Function R excludes option P and vice versa  
2 Option D excludes option V and vice versa  
3 Only available if main output voltage Uo1 = 5.1 V  
-9 Extended Temperature Range  
P Potentiometer  
Option 9 extends the operational ambient temperature  
range from 25...71°C (standard) to 40...71°C. The power  
supplies provide full nominal output power with convection  
cooling. Option -9 excludes inrush current limitation by  
NTC.  
The potentiometer provides an output voltage adjustment  
range of +10/60% of Uo nom and is accessible through a  
hole in the front cover. This feature enables compensation  
for voltage drops across the connector and wiring. Option P  
is not recommended if units are connected in parallel.  
Option P excludes the R-function. With double output units  
both outputs are affected by the potentiometer setting (dou-  
bling the voltage setting if the outputs are in series).  
If the output voltages are increased above Uo nom via R-in-  
put control, option P setting, remote sensing or option T, the  
output current(s) should be reduced accordingly so that  
Po nom is not exceeded.  
Edition 01/01.2001  
21/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
11003  
E Inrush Current Limitation  
Vo+  
The converters may be supplemented by an electronic cir-  
cuit (option E, replacing the standard built-in NTC) to  
achieve an enhanced inrush current limiting function.  
Load  
Vo–  
Vo+  
Table 17: Inrush current characteristics with option E  
Vo–  
Characteristics  
Ui = 230 V AC  
LS  
Unit  
Vo+  
typ  
max  
25.3  
50  
Vo–  
Iinr p  
tinr  
Peak inrush current  
Inrush current duration  
A
Fig. 33  
35  
ms  
An example of poor wiring for connection in parallel  
11011  
2
Vo+  
N
1
1
Control  
S+  
T
FET  
LS 4000  
3
S–  
Rectifier  
RS  
Ci  
Vo–  
RI  
P
N
Load  
Fig. 31  
2
Vo+  
Option E block diagram  
S+  
T
11002  
1
1
Ii [A]  
20  
3
LS 4000  
S–  
Capacitor Ci  
fully charged  
Vo–  
P
15  
10  
5
max. 5 units connected in parallel  
1 Leads should have equal length and cross sections and should  
run in the same cable loom.  
Normal operation  
(FET fully conducting)  
2 Diodes recommended in redundant operation only  
3 DC common point  
0
Fig. 34  
Paralleling of single output units using option T with the  
sense lines connected at the load  
5  
10  
Power bus  
tinr  
10 20 30 40 50 60 70 80  
+
t [ms]  
Vo2+  
0
Vo2–  
Fig. 32  
T
Inrush current with option E, Ui = 230 V AC, Po = Po nom  
11037  
Module  
Vo1+  
Precaution:  
Vo1–  
Subsequent switch-on cycles at start-up are limited to  
max. 10 cycles during the rst 20 seconds (cold unit)  
and at continuing on/off (TC = 95°C) max. 1 cycle every  
8 sec.  
Load  
Vo2+  
Vo2–  
T
T Current Sharing  
Module  
This option ensures that the output currents are approxi-  
mately shared between all paralleled modules and in-  
creases system reliability. To use this facility, simply inter-  
connect the T pins of all modules and make sure, that  
pin 14, the Spin (S 4000) or the Vo1pins (S 5000) are  
also connected together. The load leads should have equal  
length and cross section to ensure equal voltage drops. Not  
more than 5 units should be connected in parallel. If output  
voltage adjustment is requested we strongly recommend to  
use the R-input instead of option P, as with option P the re-  
quired setting accuracy is difcult to achieve. The output  
voltages must be individually set prior to paralleling to  
within a tolerance of 1...2% or the R pins should be con-  
nected together.  
Vo1+  
Vo1–  
max. 5 units in parallel connection  
Fig. 35  
Paralleling of double output units using option T with  
Power bus.  
Edition 01/01.2001  
22/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
D Undervoltage Monitor  
threshold level Uti is adjusted in the factory. The threshold  
level Uto is either adjusted by a potentiometer, accessible  
through a hole in the front cover, or factory adjusted to a  
xed value specied by the customer.  
The input and/or output undervoltage monitoring circuit op-  
erates independently of the built-in input undervoltage lock-  
out circuit. A logic "low" (JFET output) or "high" signal (NPN  
output) is generated at pin 20 as soon as one of the moni-  
tored voltages drops below the preselected threshold level  
Ut. The return for this signal is Vo1. The D output recovers  
when the monitored voltage(s) exceed(s) Ut + Uh. The  
Option D exists in various versions D0...DD as shown in the  
following table.  
Table 18: Undervoltage monitoring functions  
Output type  
Monitoring  
Minimum adjustment range  
of threshold level Ut  
Uti Uto  
Typical hysteresis Uho [% of Ut]  
JFET  
NPN  
Ui  
Uo1  
for Ut min...Ut max  
Uho  
D1  
D2  
D3  
D4  
D0  
D5  
D6  
D7  
D8  
D9  
no  
yes  
yes  
no  
yes  
no  
-
3.5...40 V 1  
-
2.5...0.6  
-
355V DC 4  
2
2
yes  
yes  
yes  
yes  
355V DC 4  
(0.95...0.985 Uo1  
(0.95...0.985 Uo1  
3.5...40 V 3  
3.5...40 V 3  
)
)
"0"  
-
"0"  
no  
-
2.5...0.6  
2.5...0.6  
yes  
355V DC 4  
DD  
yes  
yes  
355V DC 4  
3.5...40 V 1  
2.5...0.6  
1 Threshold level adjustable by potentiometer  
2 Fixed value. Tracking if Uo1 adjusted via R-input, option P or sense lines.  
3 The threshold level permanently adjusted according to customer specication ±2% at 25°C. Any value within the specied range is  
basically possible but causes a special type designation in addition to the standard option designations (D0/D9)!  
4 Option D monitors the boost regulator output voltage. The trigger level is adjusted in the factory to 355 V DC.  
11006  
JFET output (D0D4):  
Vo1+  
Connector pin D is internally connected via the drain-  
source path of a JFET (self-conducting type) to the nega-  
tive potential of output 1. UD 0.4 V (logic low) corresponds  
to a monitored voltage level (Ui and/or Uo1) <Ut. The cur-  
rent ID through the JFET should not exceed 2.5 mA. The  
JFET is protected by a 0.5 W Zener diode of 8.2 V against  
external overvoltages.  
R
p
I
D
D
U
D
Ui, Uo1 status  
Ui or Uo1 < Ut  
D output, UD  
Vo1–  
low, L, UD 0.4 V at ID = 2.5 mA  
high, H, ID 25 µA at UD = 5.25 V  
Fig. 36  
Ui and Uo1 > Ut + Uh  
Option D0...D4: JFET output, ID 2.5 mA  
11007  
Vo1+  
NPN output (D5...DD):  
Connector pin D is internally connected via the collector-  
emitter path of a NPN transistor to the negative potential of  
output 1. UD < 0.4 V (logic low) corresponds to a monitored  
voltage level (Ui and/or Uo1) > Ut + Uh. The current ID  
through the open collector should not exceed 20 mA. The  
NPN output is not protected against external overvoltages.  
UD should not exceed 40 V.  
R
p
I
D
D
U
D
Ui, Uo1 status  
Ui or Uo1 < Ut  
D output, UD  
Vo1–  
high, H, ID 25 µA at UD = 40 V  
low, L, UD 0.4 V at ID = 20 mA  
Fig. 37  
Option D5...DD: NPN output, Uo1 40 V, ID 20 mA  
Ui and Uo1 > Ut + Uh  
Table 19: D-output logic signals  
Version of D  
Ui < Ut resp. Uo < Ut  
Ui > Ut + Uh resp. Uo > Ut  
Conguration  
JFET  
D1, D2, D3, D4, D0  
D5, D6, D7, D8, D9, DD  
low  
high  
low  
high  
NPN  
Edition 01/01.2001  
23/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
D-signal with respect to input and output voltage versus time:  
Input voltage monitoring  
NPN  
UD  
11044  
UD high  
3
3
3
3
UD low  
0
t
ID  
ID high  
ID low  
0
t
JFET UD  
UD high  
UD low  
0
t
1
4
4
4
th  
tlow min  
tlow min  
tlow min  
thigh min  
Uo1  
Uo1 nom  
1
th  
1
0.95  
t
t
0
Uci [V DC]  
358  
355  
0
Input voltage failure  
Switch-on cycle  
Input voltage sag  
Switch-on cycle and subsequent  
input voltage failure  
Output voltage monitoring  
NPN UD  
2
UD high  
UD low  
0
t
t
ID  
ID high  
ID low  
0
UD  
JFET  
UD high  
UD low  
0
t
t
4
tlow min  
1 Hold-up time see section Electrical Input Data.  
2 With output voltage monitoring, hold-up time th = 0.  
3 The signal will remain high if the D output is connected to  
an external source.  
Uo1  
Uo1 nom  
Uto +Uho  
Uto  
4 tlow min = 100...170 ms, typically 130 ms.  
0
Output voltage failure  
Fig. 38  
Relationship between Uci, Uo1, UD, Uo1/Uo nom versus time  
Edition 01/01.2001  
24/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
V ACFAIL Signal (VME)  
V output (V2, V3):  
Available for units with Uo1 = 5.1V  
Connector pin V is internally connected to the open collec-  
tor of a NPN transistor. The emitter is connected to the  
negative potential of output 1. UV 0.6 V (logic low) corre-  
sponds to a monitored voltage level (Ui and/or Uo1) <Ut.  
The current IV through the open collector should not ex-  
ceed 50 mA. The NPN output is not protected against ex-  
ternal overvoltages. UV should not exceed 60 V.  
This option denes an undervoltage monitoring circuit for  
the input or input and main output voltage equivalent to op-  
tion D and generates the ACFAIL signal (V signal) which  
conforms to the VME standard.  
The low state level of the ACFAIL signal is specied at a  
sink current of IV 48 mA to UV 0.6 V (open-collector out-  
put of a NPN transistor). The pull-up resistor feeding the  
open-collector output should be placed on the VME back  
plane.  
Ui, Uo1 status  
Ui or Uo1 < Ut  
V output, UV  
low, L, UV 0.6 V at IV = 50 mA  
high, H, IV 25 µA at UV = 5.1 V  
After the ACFAIL signal has gone low, the VME standard  
requires a hold-up time th of at least 4 ms before the 5.1 V  
output drops to 4.875 V when the output is fully loaded.  
This hold-up time th is provided by the internal input capaci-  
tance. See also g.: Hold-up Time versus Output Power.  
Ui and Uo1 > Ut + Uh  
11009  
Vo1+  
Table 20: Undervoltage monitor functions  
R
p
I
V output  
Monitoring  
Minimum adjustment  
V
(VME compatible)  
Ui  
Uo1  
range of threshold level  
V
Uti  
no 355V DC 1  
Uto  
U
V
V2  
V3  
yes  
yes  
2
yes 355V DC 1 0.95...0.985 Uo1  
Vo1–  
1 Option D monitors the boost regulator output voltage. The trig-  
ger level is adjusted in the factory to 355 V DC.  
Fig. 39  
Output conguration of options V2 and V3  
2 Fixed value between 95% and 98.5% of Uo1  
.
Option V operates independently of the built-in input under-  
voltage lock-out circuit. A logic "low" signal is generated at  
pin 20 as soon as one of the monitored voltages drops be-  
low the preselected threshold level Ut. The return for this  
signal is Vo1. The V output recovers when the monitored  
voltage(s) exceed(s) Ut + Uh. The threshold level Uti is ad-  
justed in the factory to 355 V DC. The threshold level Uto  
either is adjusted during manufacture to a determined cus-  
tomer specied value.  
Edition 01/01.2001  
25/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
11045  
Input voltage monitoring  
2
2
2
tlow min  
tlow min  
tlow min  
V2  
UV  
3
3
3
UV high  
4
2
4
2
UV low  
t
0
tlow min  
tlow min  
V3  
UV  
3
3
3
UV high  
UV low  
t
0
1
1
th  
th  
Uo1  
5.1 V  
4.875 V  
2.0 V  
0
t
Uci [V DC]  
358  
355  
t
0
Input voltage failure  
Switch-on cycle  
Input voltage sag  
Switch-on cycle and subsequent  
input voltage failure  
Output voltage monitoring  
V2 UV  
UV high  
4
4
UV low  
t
t
0
2
tlow min  
V3 UV  
UV high  
3
3
4
UV low  
0
Uo1  
5.1 V  
4.875 V  
2.0 V  
0
t
1 VME request: minimum 4 ms  
2 tlow min = 40...200 ms, typically 80 ms  
3 UV level not dened at Uo1 < 2.0 V  
Ui  
4 The V signal drops simultaneously with the output voltage if the  
pull-up resistor RP is connected to Vo1+.  
The V signal remains high if RP is connected to an external  
source.  
Uti + Uhi  
Uti  
t
0
Output voltage failure  
Fig. 40  
Relationship between Uci, Uo1, UV, IV and Uo1/Uo nom ver-  
sus time.  
Edition 01/01.2001  
26/27  
Cassette Style  
100 Watt AC-DC Converters  
S Series PFC  
B1 Cooling Plate (see: Mechanical Data)  
Where a cooling surface is available, we recommend the  
use of a cooling plate (option B1) instead of the standard  
heatsink. The mounting system should ensure sufcient  
cooling capacity to guarantee that the maximum case tem-  
perature TC max is not exceeded. The cooling capacity is cal-  
culated by:  
(100% h)  
PLoss = –––––––––– (Uo Io)  
h
Efciency η see: Type survey.  
Elongated case for 220 mm rack depth: Option B2.  
Accessories  
A variety of electrical and mechanical accessories are  
available including:  
Front panels for 19" rack mounting, Schroff and Intermas  
systems.  
Mating H15 connectors with screw, solder, fast-on or  
press-fit terminals.  
Connector retention facilities.  
Code key system for connector coding.  
Chassis mounting plates for mounting the 19" cassette to  
a chassis/wall where only frontal access is given.  
Universal mounting bracket for DIN-rail or chassis moun-  
ting.  
For more detailed information please refer to: Accessory  
Products.  
Front panels  
H15 female connector,  
Code key system  
Chassis mounting bracket S  
Mounting plate,  
Connector retention clips  
Universal mounting bracket for DIN-rail mounting.  
Edition 01/01.2001  
27/27  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY