MAP110 [BEL]
Universal Input 85-264 VAC;型号: | MAP110 |
厂家: | BEL FUSE INC. |
描述: | Universal Input 85-264 VAC |
文件: | 总6页 (文件大小:781K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Bel Power Solutions MAP110 Series of power supplies combines low
cost and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the
CE Mark.
Wide dynamic output current and fixed-frequency operation simplifies
system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are
made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
RoHS Lead-Solder-Exemption Compliant
New 5 V Output Models
Universal Input 85-264 VAC
Industry-Standard Footprint:
7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm)
Input Transient & ESD Compliance to EN61000-4-2/-3/-4
Remote sense and overvoltage protection on single output units and
main output of multiple output units
Options include Over temperature protection, Power Fail signal,
Chassis & Cover
Greater than 134,000 hours MTBF
2
MAP110 Series
CONVECTION
COOLED
OUTPUT
FORCED AIR
OUTPUT
RIPPLE
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
LINE
REGULATION
LOAD
REGULATION
INITIAL SETTING
ACCURACY
MODEL 7
&
CURRENT 1
NOISE 2
CURRENT
MAP110-1005*
MAP110-1012G
MAP110-1024G
5V
12V
4.95V to 5.5V
11.25V to 12.75V
22.8V to 29.2V
16A
7.5A
22A
10A
0.2%
0.1%
0.1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.02V
23.95V to 24.05V
0.5%
0.5%
24V/28V
3.8/3.2A 3
5/4.3A 3
CONVECTION
COOLED
FORCED AIR
OUTPUT
RIPPLE
&
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
LINE
REGULATION
LOAD
REGULATION
INITIAL SETTING
ACCURACY
MODEL 7
OUTPUT
CURRENT 4
NOISE2
CURRENT 4
+5V
+12V
-12V
-5V
4.75V to 5.25V
Fixed
12A/20A PK
5A/9A PK
12A/20A PK
5A/9A PK
0.2%
0.2%
0.2%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.2%
0.3%
0.2%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
-4.75V to -5.25V
5.09V to 5.11V
23.94V to 24.06V
-11.4V to -12.6V
11.4V to 12.6V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
11.4V to 12.6V
5.09V to 5.11V
14.96V to 15.04V
-14.3V to -15.7V
-4.75V to -5.25V
5.09V to 5.11V
23.94V to 24.06V
-14.3V to -15.7V
14.3V to 15.7V
5.09V to 5.11V
11.97V to 12.03V
-4.75V to -5.25V
-11.5V to -12.5V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
23.2V to 24.8V
5.09V to 5.11V
11.97V to 12.03V
MAP110-4000G
Fixed
1A/1.5A PK
1A/1.5A PK
12A/20A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
1%
Fixed
1.5%
0.5%
1%
+5V
4.75V to 5.25V
Fixed
+24V
-12V
+12V
+5V
3A/4.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
MAP110-4001*
MAP110-4002G
MAP110-4003*
MAP110-4004G
MAP110-4010*
Fixed
1%
1A/1.5A PK
12A/20A PK
1A/1.5A PK
12A/20A PK
Fixed
1%
4.75V to 5.25V
Fixed
0.5%
1%
+12V
-12V
+12V
+5V
5A/9A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
Fixed
1%
1A/1.5A PK
12A/20A PK
1A/1.5A PK
12A/20A PK
Fixed
1%
4.75V to 5.25V
Fixed
0.5%
1%
+15V
-15V
-5V
5A/7.3A PK
1A/1.5A PK
5A/7.3A PK
1A/1.5A PK
Fixed
1%
1A/1.5A PK
12A/20A PK
1A/1.5A PK
12A/20A PK
Fixed
1.5%
0.5%
1%
+5V
4.75V to 5.25V
Fixed
+24V
-15V
+15V
+5V
3A/4.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
Fixed
1%
1A/1.5A PK
1A/1.5A PK
Fixed
1%
4.75V to 5.25V
Fixed
12A/20A PK
5A/9A PK
12A/20A PK
5A/9A PK
0.5%
2%
+12V
-5V
Fixed
1A/1.5A PK
3A/4A PK
1A/1.5A PK
3A/4A PK
1.5%
8%
-12V
+5V
Fixed
4.75V to 5.25V
Fixed
12A/20A PK
5A/9A PK
12A/20A PK
5A/9A PK
0.5%
1%
+12V
-12V
+24V
+5V
0.1%
0.1%
MAP110-4011G
MAP110-4015*
Fixed
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1%
0.1%
Fixed
1%
4.75V to 5.25V
Fixed
0.2%
0.1%
0.5%
1%
+12V
tech.support@psbel.com
3
MAP110 Series
0.1%
0.1%
-15V
Fixed
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1%
1%
1%
1%
-14.4V to -15.6V
+15V
Fixed
14.4V to 15.6V
11.55V to
12.45V
+12V
5A/9A PK
5A/9A PK
0.2%
0.5%
0.5%
11.96V to 12.03V
+24V
-12V
+5V
Fixed
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
0.2%
0.2%
0.2%
0.3%
0.2%
0.1%
0.1%
0.3%
0.2%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
MAP110-4200G
Fixed
Fixed
1.5%
0.7%
1%
+3.3V
+5V
3.2V to 3.4V
Fixed
MAP110-4300* 5,6
MAP110-4305* 5,6
-12V
+12V
+3.3V
+5V
Fixed
1%
Fixed
1%
3.2V to 3.4V
Fixed
0.7%
1%
-5V
Fixed
1%
+12V
Fixed
1%
1 With minimum 200LFM forced-air cooling.
2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3 MAP110-1024 output currents are expressed as 24V/28V operation.
4 Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts.
5 Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
6 Maximum operating ambient temperature of 40°C
7 Non-G models use lead solder exemption and are not recommended for new designs.
* Obsolete
MULTIPLE OUTPUT
BOARD ONLY
SINGLE OUTPUT
BOARD ONLY
MULTIPLE OUTPUT
SINGLE OUTPUT
MODEL/OUTPUT OPTION
‘C’-COVER
C’-COVER
Convection Continuous /
Peak
80W/110W
110W
90W/120W
120W
60W/110W
110W
65W/120W
120W
Forced Air 200 LMF
PARAMETER
CONDITIONS / DESCRIPTION
Continuous input range
AC input
MIN
85
NOM
MAX
264
63
UNITS
VAC
Hz
Input Voltage - AC
Input Frequency
47
Lowest AC input voltage when regulation is maintained with full
rated loads.
Brown Out Protection
Hold-up Time
85
VAC
mS
Nominal AC input voltage (110 VAC)
40
20
50% load:
Full rated load:
85 VAC (110W load)
110VAC (110W load)
3.5
2.8
Input Current
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C.
Switching frequency of main transformer, (fixed frequency).
Inrush Surge Current
Operating Frequency
41
25
APK
20
kHz
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2016 Bel Power Solutions & Protection
BCD.00566_AB
4
MAP110 Series
PARAMETER
Efficiency
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Amps
Full load @ 230 VAC (Varies with distribution of loads among
outputs.)
70% typical
Single output models
0
1
Minimum Loads
Multiple output models, V1 + V28
Ripple and Noise
Output Power
Full Load, 20 MHz Bandwidth.
See Model Selection Chart
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
5
5
80
110
Watts
%
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
1
Varies by output, regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to
100% load.
Regulation
See Model Selection Chart
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple
output units).
Transient Response
500
µS
Turn-on Delay
Time required for initial output voltage stabilization.
1
Sec
mS
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
8 Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
V
MAP110-1005G
MAP110-1012G
MAP110-1024G
MAP110-4200G
MAP110-4300G
All other models
6.10
17.3
32.2
13.8
3.7
7.20
20.2
37.8
16.2
4.35
6.75
Provided on single output models and the
main output of multiple output models.
Overvoltage Protection
5.75
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Overload Protection
150
5
200
250
%
mV
mS
Remote Sense
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout
due to loss of input power at 110 VAC. Active low.
Input Power Fail Warning
Over temperature Protection
3
Option, system shutdown due to excessive internal temperature.
CONDITIONS / DESCRIPTION
PARAMETER
MIN
NOM
MAX
UNITS
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Agency Approvals
Input to Chassis
Input to Output (tested by manufacturer only)
2121
4242
Dielectric Withstand Voltage
VDC
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated
EN55022 / CISPR 22 conducted
B
B
A
Electromagnetic Interference,
Conducted
Class
EN55022 / CISPR 22 radiated9
Input Transient Protection
Insulation Resistance
Leakage Current
EN61000-4-5 Level 3
Input to output
2
kV
MΩ
μA
10
Per EN60950, 264 VAC
750
9 The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
tech.support@psbel.com
5
MAP110 Series
PARAMETER
Altitude
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
ASL Ft.
Operating
Non-operating
10k
50k
Derate linearly above 50°C by 2.5% per °C to a max. temp. of 70°C
Operating Temperature
At 100% load:
At 50% load:
0
0
50
70
°C
Storage Temperature
Temperature Coefficient
Relative Humidity
-55
85
±0.05
95
°C
0°C to 70°C (after 15 minute warm-up)
Non-condensing
±0.03
%/°C
%RH
PARAMETER
Dimensions
Weight
CONDITIONS / DESCRIPTION
177.8 x 109.2 x 50.0 mm (7.00 x 4.30 x 1.97 inch)
0.59 kg (1.3 lbs)
Cover
Add ‘C’ suffix to model number (Please check with Factory for availability)
Add ‘P’ suffix to model number. Provides >5 mS typical warning time before main output drops 5%.
Warning time increases at reduced load levels.
Power Fail Signal
Thermal Shutdown
Add ‘T’ suffix to model number. Initiates shut-down in the event of an over temperature condition.
Automatic recovery.
Please consult factory regarding availability of a specific version.
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2016 Bel Power Solutions & Protection
BCD.00566_AB
6
MAP110 Series
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
tech.support@psbel.com
相关型号:
©2020 ICPDF网 联系我们和版权申明