MDU150-4350G [BEL]

AC-DC Power Factor Correction Module,;
MDU150-4350G
型号: MDU150-4350G
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Power Factor Correction Module,

文件: 总8页 (文件大小:1212K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The innovative MPU products incorporate Power Factor Correction  
(PFC) with a low-profile package designed to meet 1U height  
constraints. The MPU150-4530G and MPU150-4350G provide high  
current +3.3 V and +5 V on a single platform to support mixed-mode,  
high-speed digital circuitry. Bel Power Solutions unique dual converter  
architecture combines high reliability with exceptional regulation.  
All multiple output models feature remote sense on outputs V1 and V2  
to provide independent compensation of output cable losses. Other  
standard features include independent current sharing on V1 and V2,  
thermal shutdown, and remote inhibit. Airflow of 300 linear feet per  
minute (LFM) is required to deliver the full power density of 3.0 watts  
per cubic inch.  
The MDU150 Series provides the same benefits as the MPU150  
Series, with nominal 48 volt DC input.  
RoHS Compliant  
Power Factor Correction (PFC)  
Low-profile height fits 1U constraints  
Dual main outputs provide 3.3 V and 5 V for mixed mode applications  
Single wire current sense on outputs V1 and V2  
Remote sense on outputs V1 and V2  
Overtemperature, overload, and overvoltage protection  
Available with metric or SAE mountings  
Greater than 340000 Hours MTBF  
MDU150 models have 48 VDC input  
Asia-Pacific  
Europe, Middle East  
North America  
+86 755 298 85888  
+353 61 225 977  
+1 866 513 2839  
© 2015 Bel Power Solutions, Inc.  
BCD.00603_AA  
2
180 W with 300 LFM Forced-Air Cooling  
MAXIMUM  
OUTPUT  
RIPPLE &  
NOISE  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
LINE  
LOAD  
INITIAL SETTING  
ACCURACY  
MODEL6  
REGULATION REGULATION  
CURRENT 1  
% pk-pk 2  
MPU150-S259G  
MPU150-S262G  
MPU150-S261G  
12V  
24V  
48V  
11.6V to 16V  
22.8V to 29.2V  
45V to 56V  
15A 3  
7.5A 3  
3.75A 3  
0.1%  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
47.9V to 48.1V  
150 W with 300 LFM Forced-Air Cooling - Isolated V3 and V4 can be used as positive or negative outputs  
RIPPLE &  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
OUTPUT  
LINE  
LOAD  
INITIAL SETTING  
ACCURACY  
MODEL6  
NOISE  
CURRENT 1 REGULATION REGULATION  
% pk-pk 2  
+3.3V  
+5V  
3.15V to 3.80V  
5.0V to 5.5V  
35A  
20A  
0.6%  
0.4%  
1.5%  
3%  
1.5%  
1%  
3.28V to 3.32V  
4.98V to 5.02V  
MPU150-3300G  
+12V  
+5V  
Fixed  
2A  
17.5A  
4A  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.8%  
0.6%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
3%  
1%  
3%  
3%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1.5%  
1%  
7%  
7%  
1%  
1.5%  
7%  
7%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1.5%  
1%  
1%  
11.76V to 12.24V  
4.98V to 5.02V  
11.94V to 12.06V  
23.52V to 24.48V  
4.98V to 5.02V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
2.49V to 2.51V  
3.28V to 3.32V  
11.94V to 12.06V  
4.98V to 5.0V  
5.0V to 5.5V  
10.8V to 13.2V  
Fixed  
MPU150-3524G  
MPU150-4000G  
+12V  
+24V  
+5V  
2A  
30A 4  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
2.25V to 3.0V  
3.15V to 3.8V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.80V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
+12V  
12V  
8A  
3A  
5V  
2A  
+2.5V  
+3.3V  
12V  
30A 4  
15A 4  
4A 5  
2A 5  
30A 4  
15A 4  
3A 5  
3A 5  
30A 4  
15A 4  
3A 5  
3A 5  
MPU150-4230G  
MPU150-4350G  
MPU150-4530G  
5V  
+3.3V  
+5V  
3.28V to 3.32V  
5.00V to 5.04V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.94V to 12.06V  
12V  
12V  
+5V  
+3.3V  
12V  
12V  
NOTES:  
1
The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions.  
It is recommended that the airflow be applied from the input side of the power supply blowing towards the output.  
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
Total power of 180 Watts.  
Total current between V1 and V2 is 30A, maximum rating.  
Total current between V3 and V4 is 5A, maximum rating.  
2
3
4
5
6
Non-G models use lead solder exemption and are not recommended for new designs.  
tech.support@psbel.com  
3
150 W with 300 LFM Forced-Air Cooling - Isolated V3 and V4 can be used as positive or negative outputs  
RIPPLE &  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
OUTPUT  
LINE  
LOAD  
INITIAL SETTING  
ACCURACY  
MODEL6  
NOISE  
CURRENT 1  
REGULATION REGULATION  
% pk-pk 2  
+3.3V  
+5V  
3.15V to 3.80V  
5.0V to 5.5V  
N/A  
35A  
20A  
2A  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
2%  
1.5%  
3%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1.5%  
1%  
1%  
3.28V to 3.32V  
4.98V to 5.02V  
11.76V to 12.24V  
4.98V to 5.02V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
2.49V to 2.51V  
3.28V to 3.32V  
11.94V to 12.06V  
4.98V to 5.0V  
MDU150-3300G  
+12V  
+5V  
3%  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
2.25V to 3.0V  
3.15V to 3.8V  
10.8V to 13.2V  
5.0V to 5.5 V  
3.15V to 3.8V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
30A 3  
8A  
1%  
+12V  
12V  
1%  
MDU150-4000G  
MDU150-4230G  
MDU150-4350G  
MDU150-4530G  
3A  
1%  
5V  
2A  
1%  
+2.5V  
+3.3V  
12V  
30A 3  
15A 3  
3A  
2%  
1.5%  
1%  
1.5%  
1%  
5V  
2A  
1%  
1%  
+3.3V  
+5V  
30A 5  
15A 5  
3A 4  
3A 4  
30A 3  
15A 3  
3A 4  
3A 4  
1.5%  
1%  
1.5%  
1%  
3.28V to 3.32V  
5.00V to 5.04V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.94V to 12.06V  
12V  
7%  
7%  
12V  
7%  
7%  
+5V  
0.4%  
0.6%  
0.4%  
0.4%  
1%  
+3.3V  
12V  
1.5%  
7%  
12V  
7%  
NOTES:  
1
The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions.  
It is recommended that the airflow be applied from the input side of the power supply blowing towards the output.  
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
Total current between V1 and V2 is 30A, maximum rating.  
Total current between V3 and V4 is 5A, maximum rating.  
Total current between V1 and V2 is 40A, maximum rating.  
2
3
4
5
6
Non-G models use lead solder exemption  
OPTIONS  
SUFFIXES TO ADD TO PART NUMBER  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts.  
RoHS lead solder exempt  
No RoHS suffix character required.  
RoHS compliant for all 6 substances  
Add “G” as the last character of the part number.  
tech.support@psbel.com  
4
PARAMETER  
CONDITIONS / DESCRIPTION  
Continuous input range.  
AC input.  
MIN  
85  
NOM  
MAX  
264  
63  
UNITS  
VAC  
Hz  
Input Voltage - AC  
Input Frequency  
47  
MPU150-4350G  
All other models  
17.5  
20  
Hold-up Time  
After last AC line peak at 150 watts.  
85 VAC at full rated load.  
ms  
Input Current  
MPU150  
3.0  
35  
ARMS  
Input Protection  
Inrush Surge Current  
Power Factor  
Non-user serviceable internally located AC input line fuse.  
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.  
Per EN61000-3-2.  
APK  
0.95  
W/VA  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
Switching frequency of Power Factor Correction circuit.  
100  
65  
120  
90  
Operating Frequency  
kHz  
60  
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Input Voltage - DC  
Continuous input range.  
36  
75  
VDC  
Lowest DC input voltage that regulation is maintained with full  
rated loads.  
Brown Out Protection  
34  
20  
VDC  
Hold-up Time  
Input Current  
Input Protection  
At 150 watts, over DC input range.  
ms  
36 VDC at full rated load.  
6.4  
ARMS  
Non-user serviceable internally located AC input line fuse.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
100  
70  
Operating Frequency  
Inrush Current  
kHz  
Consult factory.  
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Full Rated Load, 110 VAC.  
Varies with distribution of loads among outputs.  
Efficiency  
65  
75  
%
Minimum load required to maintain  
Triple output models V1  
4
3
0
regulation on, V2 at maximum load.  
Quad output models V1  
Minimum Load, V1  
A
A
Minimum load required on single  
Single output models V1  
output models.  
Minimum load required to maintain  
regulation on V4 at maximum load.  
Quad output models V3  
Triple output models V3  
0.3  
0
Minimum Load, V3  
Ripple and Noise  
Output Power  
Full load, 20 MHz bandwidth.  
See Model Selection Charts  
Watts  
With 300 LFM forced air cooling.  
(Note 1)  
150  
0
Overshoot / Undershoot  
Output voltage overshoot/undershoot at turn-on.  
3
5
%
µs  
Varies by output. Total regulation includes: line changes over  
the specified. Input range, changes in load starting at 20% load  
and changing to 100% load.  
Recovery time, to within 1% of initial set point due to a 50-  
100% load change, 5% max. deviation.  
Regulation  
See Model Selection Charts  
500  
Transient Response  
Turn-on Delay  
Time required for initial output voltage stabilization.  
2
s
Turn-on Rise Time  
Time required for output voltage to rise from 10% to 90%.  
50  
ms  
NOTE 1: This product is not rated for convection applications.  
tech.support@psbel.com  
5
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
2.5 V output, V1  
3.3 V output, V1  
3.3 V output, V2  
5 V output, V1, V2  
12 V output, V2  
12 V output, V3  
MPU150-4350G  
3.3 V output, V1  
3.0  
4.1  
3.8  
6.0  
14  
14  
4.3  
3.25  
4.65  
4.2  
6.4  
16  
19  
4.65  
Latch style overvoltage protection.  
Available on V1, V2, all models,  
and V3 on all models except  
MPU150-3300G.  
Overvoltage Protection  
V
Fully protected against output overload and short circuit.  
Automatic recovery upon removal of overload condition.  
System shutdown due to excessive internal temperature,  
automatic reset.  
Overload Protection  
Overtemperature  
Protection  
TTL compatible signal available for V1. Pull-up resistor  
is 10kΩ.  
Signal is high when output is above the specified limits.  
Signal shall remain low for 20 ms following loss of  
Output Good.  
3.3 V  
5 V  
3.16  
4.75  
3.25  
4.90  
Output Good Signal,  
Low to High Transition  
V
TTL compatible logic signal. Time before regulation dropout  
Input Power Fail Warning due to loss of input power. May be used as independent  
PSOK signal in redundant applications.  
5
ms  
Accuracy of shared current with up to 6 parallel units. Single  
wire current share on V1 and V2 with return via -Sense return.  
Current Share  
10  
%
Available on V1 and V2. Total voltage compensation for cable  
losses with respect to the main output.  
Remote Sense  
500  
mV  
Output voltage is inhibited by application of an external high  
(5V) signal.  
Inhibit  
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Approved to the latest edition of the following standards:  
CSA/UL60950-1, EN60950-1 and IEC60950-1  
Safety Approvals  
Dielectric Withstand  
Voltage  
MPU150  
MDU150  
2600  
1544  
Input to output per EN60950.  
VDC  
Electromagnetic  
Interference  
FCC CFR title 47 Part 15 Sub-Part B - Conducted.  
EN55022 / CISPR 22 Conducted.  
B
B
Class  
ESD Susceptibility  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-2, level 4.  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 3.  
8
kV  
V/M  
kV  
10  
±2  
MPU150: Line to Line  
MPU150: Line to Ground  
1
2
Input Transient Protection Per EN61000-4-5, class 3.  
kV  
MDU150: Line to Line  
MDU150: Line to Ground  
0.5  
0.5  
MΩ  
Insulation Resistance  
Leakage Current  
Input to output.  
Per EN60950.  
10  
22  
1.7  
Dual output MPU150 at 264 VAC  
Single and triple output MPU150 at 264 VAC  
MDU150 at 72 VDC  
mA  
(Not required by EN60950)  
tech.support@psbel.com  
6
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Operating.  
Non-Operating.  
10k  
40k  
50  
Altitude  
ASL Ft.  
At 100% load  
At 50% load  
0
0
Operating Temperature  
°C  
Derate linearly above 50°C by 2.5% per °C.  
70  
Storage Temperature  
Temperature Coefficient  
Relative Humidity  
Shock  
-55  
5
85  
±0.05  
95  
°C  
0°C to 70°C (after 15 minute warm-up).  
Non-Condensing.  
±0.02  
%/°C  
%RH  
GPK  
Peak acceleration.  
20  
Vibration  
Random vibration, 10Hz to 2kHz, 3 axis.  
6
GRMS  
PARAMETER  
Dimensions  
Weight:  
DESCRIPTION  
8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm)  
2 lb (0.89 kg)  
MATES WITH MOLEX:  
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)  
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)  
Figure 1. Mechanical Drawing Single Output  
tech.support@psbel.com  
7
CONNECTOR  
MOLEX SERIES  
41695  
HOUSING  
09-50-8051  
09-50-8051  
09-50-3051  
50-37-5103  
PIN SERIES  
6838  
PINS (LOOSE)  
08-50-0189  
08-50-0106  
08-50-0106  
08-70-1040  
PINS (CHAIN)  
08-50-0187  
08-50-0105  
08-50-0105  
08-70-1039  
WIRE GAUGE  
18-20AWG  
18-20AWG  
18-20AWG  
22-28AWG  
J1  
41695  
2478  
(ALL MODELS)  
2139  
2478  
J300  
5264-N  
5263  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH  
Figure 2. Mechanical Drawing Triple & Quad Output  
tech.support@psbel.com  
8
CONNECTOR  
MOLEX SERIES  
HOUSING  
PIN SERIES  
PINS (LOOSE)  
PINS (CHAIN)  
WIRE GAUGE  
41695  
41695  
2139  
09-50-8051  
09-50-8051  
09-50-3051  
22-01-1022  
22-01-1022  
09-50-8021  
09-50-8021  
09-50-3021  
09-50-8061  
09-50-8061  
09-50-3061  
50-37-5103  
6838  
2478  
2478  
2759  
2759  
6838  
2478  
2478  
6838  
2478  
2478  
5263  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0114  
08-65-0805  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0189  
08-50-0106  
08-50-0106  
08-70-1040  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0113  
08-65-0804  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0187  
08-50-0105  
08-50-0105  
08-70-1039  
18-20AWG  
18-20AWG  
18-20AWG  
22-30AWG  
22-30AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
22-28AWG  
J1 (ALL MODELS)  
5051-N  
5051-N  
41695  
41695  
2139  
J2 (TRIPLE  
OUTPUT)  
J3 (TRIPLE  
OUTPUT)  
41695  
41695  
2139  
J3 (QUAD  
OUTPUT)  
J300  
5264-N  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com  

相关型号:

MDU150-4350M

AC-DC Power Factor Correction Module,
BEL

MDU150-4350MG

AC-DC Power Factor Correction Module,
BEL

MDU150-4530

Power Factor Correction (PFC) Meets EN61000-3-2
POWER-ONE

MDU150-4530G

DC-DC Regulated Power Supply Module, 4 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MDU150-4530M

AC-DC Power Factor Correction Module,
BEL

MDU150-4530MG

AC-DC Power Factor Correction Module,
BEL

MDU1511

Single N-channel Trench MOSFET 30V, 100.0A, 2.4m(ohm)
MGCHIP

MDU1511RH

Single N-channel Trench MOSFET 30V, 100.0A, 2.4m(ohm)
MGCHIP

MDU1512

Single N-channel Trench MOSFET 30V, 100.0A, 3.4m(ohm)
MGCHIP

MDU1512RH

Single N-channel Trench MOSFET 30V, 100.0A, 3.4m(ohm)
MGCHIP

MDU1513

Single N-channel Trench MOSFET 30V, 88.1A, 4.6m(ohm)
MGCHIP

MDU1513URH

Single N-channel Trench MOSFET 30V, 88.1A, 4.6m(ohm)
MGCHIP