MPU200/MDU200 Series Data Sheet  
Features  
RoHS lead free solder and lead solder exempted products  
are available  
Power Factor Correction (PFC) meets EN61000-3-2  
Same size, airflow, and construction as MPU150/MDU150  
with over 33% more power  
Single-wire current sense on quad model outputs V1 and V2  
Remote sense on quad model outputs V1 and V2  
Current share and N+1 redundancy (standard on all models)  
Overtemperature, overload, and overvoltage protection  
Available with SAE mountings  
MDU200 models have 48 VDC input  
Description  
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products  
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series,  
200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power  
applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital  
circuitry.  
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature  
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.  
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote  
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.  
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 VDC input.  
AC Input, Single-Output Model Selection  
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 2)  
PEAK OUTPUT  
CURRENT (NOTE 2) REGULATION  
LINE  
LOAD  
REGULATION  
RIPPLE & NOISE  
%p-p (NOTE 3)  
INITIAL SETTING  
ACCURACY  
MODEL  
MPU200-1012G  
MPU200-1024G  
MPU200-1048G  
12V  
24V  
48V  
11.6V to 16V  
22.8V to 29.2V  
45V to 56V  
17.0A  
8.35A  
4.2A  
19.0A  
9.4A  
4.7A  
0.1%  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
47.9V to 48.1V  
AC Input, Multiple-Output Model Selection  
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)  
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 2)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 3)  
INITIAL SETTING  
ACCURACY  
MODEL  
+5V  
+3.3V  
12V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
30A (Note 4)  
15A (Note 4)  
8A (Note 5)  
4A (Note 5)  
0.4%  
0.6%  
0.4%  
0.4%  
1%  
1.5%  
10%  
10%  
1%  
1.5%  
1%  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.60V to 12.40V  
MPU200-4530  
12V  
1%  
NOTES: 1) This product is not rated for convection applications.  
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be  
applied from the input side of the power supply blowing towards the output.  
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
4) Total current for V1 and V2 is not to exceed 35A.  
5) Total power on V3 and V4 is not to exceed 100W.  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
Ordering Information:  
OPTIONS  
SUFFIXES TO ADD TO PART NUMBER  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M3 x 0.7 mounting inserts. Consult factory for availability.  
Isolation Diode  
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.  
Consult factory for availability.  
RoHS lead solder exemption  
No RoHS suffix character required.  
RoHS compliant for all 6 substances  
Add “G” as the last character of the part number.  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 1 of 6  
www.power-one.com  
MPU200/MDU200 Series Data Sheet  
DC Input, Single Output Model Selection  
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 2) CURRENT (NOTE 2) REGULATION  
PEAK OUTPUT  
LINE  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 3)  
INITIAL SETTING  
ACCURACY  
MODEL  
MDU200-1012G  
12V  
24V  
11.6V to 16V  
17.0A  
8.35A  
19.0A  
9.4A  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
MDU200-1024G  
(NOTE 4)  
22.8V to 29.2V  
MDU200-1048G  
48V  
45V to 56V  
4.2A  
4.7A  
0.1%  
1%  
1%  
47.9V to 48.1V  
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
MPU200 Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
85  
NOM  
MAX  
264  
63  
UNITS  
Input Voltage - AC  
Input Frequency  
Hold-up Time  
Continuous input range.  
VAC  
Hz  
AC input.  
47  
After last AC line peak at 200 watts  
85 VAC at full rated load.  
15  
ms  
Input Current  
4.0  
35  
ARMS  
Input Protection  
Inrush Surge Current  
Power Factor  
Non-user serviceable internally located AC input line fuse.  
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.  
Per EN61000-3-2.  
APK  
0.95  
100  
65  
W/VA  
Operating Frequency  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
Switching frequency of Power Factor Correction circuit.  
120  
90  
kHz  
60  
MDU200 Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
36  
NOM  
MAX  
UNITS  
VDC  
VDC  
ms  
Input Voltage - DC  
Brown Out Protection  
Hold-up Time  
Continuous input range.  
75  
Lowest DC input voltage that regulation is maintained with full rated loads.  
At 200 watts, over DC input range.  
34  
15  
Input Current  
36 VDC at full rated load.  
8.35  
ARMS  
Input Protection  
Inrush Surge Current  
Operating Frequency  
Non-user serviceable internally located AC input line fuse.  
Consult factory.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
100  
70  
kHz  
NOTES:1) This product is not rated for convection applications.  
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be  
applied from the input side of the power supply blowing towards the output.  
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
4) Derating is required on output voltages above 27VDC. Consult factory.  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 2 of 6  
www.power-one.com  
MPU200/MDU200 Series Data Sheet  
Output Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Efficiency  
Full Rated Load, 110 VAC (MPU) or 48VDC (MDU).  
Varies with distribution of loads among outputs.  
65  
75  
%
Minimum Load, V1  
Minimum Load, V3  
Minimum load required to maintain regulation on,  
V2 at maximum load.  
Minimum load required on single output models.  
Quad output model V1  
Single output models V1  
3
0
A
A
Minimum load required to maintain regulation on  
V4 at maximum load.  
Quad output model V3  
0.3  
Ripple and Noise  
Overshoot / Undershoot  
Regulation  
Full load, 20 MHz bandwidth.  
See Model Selection Charts  
5
Output voltage overshoot/undershoot at turn-on.  
%
Varies by output. Total regulation includes: line changes over the specified.  
input range, changes in load starting at 20% load and changing to 100% load.  
See Model Selection Charts  
Transient Response  
Recovery time, to within 1% of initial set point due to a 50-100% load change,  
5% max. deviation.  
500  
2
μs  
Turn-on Delay  
Time required for initial output voltage stabilization.  
s
Turn-on Rise Time  
Time required for output voltage to rise from 10% to 90%.  
MPU200  
MDU200  
50  
80  
ms  
Interface Signals and Internal Protection  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Overvoltage Protection  
Latch style overvoltage protection.  
MPU200-4530 3.3V output  
MPU200-4530 5V output  
MPU200-4530 12V output  
3.8  
6.0  
14  
4.2  
6.4  
19  
V
MDU200/MPU200-1012 V1 17.0  
MDU200/MPU200-1024 V1 32.0  
MDU200/MPU200-1048 V1 58.0  
20.5  
38.0  
62.7  
Overload Protection  
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.  
System shutdown due to excessive internal temperature, automatic reset.  
Overtemperature Protection  
Output Good Signal  
(Transision from  
Low to High)  
TTL compatible signal available for V1. Internal pull-up resistor is 475.  
Signal is high when output is above the specified limits. Signal shall  
remain low for 20 milliseconds following loss of Output Good.  
3.3V 3.16  
5V 4.75  
3.25  
4.95  
V
MDU200/MPU200-1012 12V 10.5  
MDU200/MPU200-1024 24V 21.5  
MDU200/MPU200-1048 48V 43.0  
11.9  
23.5  
47.0  
Input Power Fail Warning  
Current Share  
Remote Sense  
Inhibit  
TTL compatible logic signal. Time before regulation dropout due to loss of input  
power. May be used as independent PSOK signal in redundant applications.  
5
ms  
%
Accuracy of shared current with up to 6 parallel units. Single wire current share  
on V1 and V2 with return via -Sense return.  
10  
Available on V1 and V2. Total voltage compensation for cable losses with  
respect to the main output.  
500  
mV  
Output voltage is inhibited by application of an external high (5V) signal.  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 3 of 6  
www.power-one.com  
MPU200/MDU200 Series Data Sheet  
Safety, Regulatory, and EMI Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL60950,CSA 22.2 NO. 60950, and EN60950-1 (TÜV).  
Input to output per EN60950.  
(Approved)  
Dielectric Withstand Voltage  
MPU200 2600  
MDU200 1414  
VDC  
Electromagnetic Interference  
FCC CFR title 47 Part 15 Sub-Part B - Conducted.  
EN55022 / CISPR 22 Conducted.  
B
B
Class  
ESD Susceptibility  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-2, level 4.  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 3.  
8
kV  
V/M  
kV  
10  
±2  
Input Transient Protection  
Per EN61000-4-5, class 3.  
MPU200:  
Line to Line  
1
MPU200:  
MDU200:  
MDU200:  
Line to Ground  
Line to Line  
Line to Ground  
2
0.5  
0.5  
kV  
Insulation Resistance  
Leakage Current  
Input to output.  
Per EN60950.  
10  
MV  
mA  
MPU200 Quad Output Model  
MPU200 Single Output Models  
2.2  
1.7  
N/A  
MDU200 at 72 VDC  
(Not required by EN60950)  
Environmental Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Altitude  
Operating.  
Non-Operating.  
10k  
40k  
ASL Ft.  
ASL Ft.  
Operating Temperature  
At 100% load  
At 50% load  
0
0
50  
70  
°C  
°C  
Derate linearly above 50°C by 2.5% per °C.  
Storage Temperature  
Temperature Coefficient  
Relative Humidity  
Shock  
-55  
85  
±0.05  
95  
°C  
0°C to 70°C (after 15 minute warm-up).  
Non-Condensing.  
±0.02  
%/°C  
%RH  
GPK  
5
Peak acceleration.  
20  
Vibration  
Random vibration, 10Hz to 2kHz, 3 axis.  
6
GRMS  
Options  
DESCRIPTION  
NOTES  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M3 x 0.7 mounting inserts. Consult factory for availability.  
Isolation Diode  
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for  
availability.  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 4 of 6  
www.power-one.com  
MPU200/MDU200 Series Data Sheet  
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)  
OUTPUTS:  
SINGLE OUTPUT  
8-32 SCREW  
CONNECTIONS  
(4PL)  
+V1  
RTN  
INTERFACE CONNECTIONS (J300)  
PIN  
MDU200  
DC  
V1,V.  
10. +S, V1  
9. -S, V1  
ADJ.  
INPUT  
J1  
5
+
8. CURRENT SHARE, V1  
7. NO CONNECTION  
+
4
3
2
1
6. NO CONNECTION  
5. NO CONNECTION  
4. OUTPUT GOOD, V1  
3. POWER FAIL WARNING  
2. INHIBIT  
MPU200  
J1  
1. SIGNAL GROUND  
AC  
L
1
3
5
INPUT  
N
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS  
ON 2.50mm CENTERS.  
MATES WITH MOLEX:  
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)  
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)  
3
TBD  
NOTE:  
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)  
ON THE FOUR BOTTOM MOUNTING HOLES.  
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)  
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING  
HOLES.  
MOLEX  
SERIES  
41695  
41695  
2139  
PIN  
PINS  
PINS  
WIRE  
CONNECTOR  
J1  
HOUSING  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,  
WITH CLEAR FINISH  
SERIES (LOOSE)  
(CHAIN)  
GAUGE  
09-50-8051  
09-50-8051  
09-50-3051  
6838 08-50-0189 08-50-0187 18-20AWG  
2478 08-50-0106 08-50-0105 18-20AWG  
2478 08-50-0106 08-50-0105 18-20AWG  
J300  
5264-N  
50-37-5103  
5263 08-70-1040 08-70-1039 22-28AWG  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 5 of 6  
www.power-one.com  
MPU200/MDU200 Series Data Sheet  
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)  
3
TBD  
NOTE:  
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)  
ON THE FOUR BOTTOM MOUNTING HOLES.  
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)  
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING  
HOLES.  
MOLEX  
SERIES  
PIN  
SERIES  
PINS  
(LOOSE)  
PINS  
(CHAIN)  
WIRE  
GAUGE  
CONNECTOR  
HOUSING  
41695  
41695  
2139  
5051-N  
5051-N  
41695  
41695  
2139  
09-50-8051  
09-50-8051  
09-50-3051  
22-01-1022  
22-01-1022  
09-50-8021  
09-50-8021  
09-50-3021  
09-50-8061  
09-50-8061  
09-50-3061  
50-37-5103  
6838  
2478  
2478  
2759  
2759  
6838  
2478  
2478  
6838  
2478  
2478  
5263  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0114  
08-65-0805  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0189  
08-50-0106  
08-50-0106  
08-70-1040  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0113  
08-65-0804  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0187  
08-50-0105  
08-50-0105  
08-70-1039  
18-20AWG  
18-20AWG  
18-20AWG  
22-30AWG  
22-30AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
22-28AWG  
J1  
(ALL MODELS)  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,  
WITH CLEAR FINISH  
J2  
(TRIPLE OUTPUT)  
J3  
(TRIPLE OUTPUT)  
41695  
41695  
2139  
J3  
(QUAD OUTPUT)  
J300  
5264-N  
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components  
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective  
divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
MCD10010 Rev. 1.1, 27-Jan-10  
Page 6 of 6  
www.power-one.com  

相关型号:

MDU200-1048G

Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE

MDU200-1048G

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MDU2511S

Single N-channel Trench MOSFET 30V, 188A, 1.7m(ohm)
MGCHIP

MDU2511SVRH

Single N-channel Trench MOSFET 30V, 188A, 1.7m(ohm)
MGCHIP

MDU28C

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC

MDU28C-10

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC

MDU28C-100

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC

MDU28C-100A1

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC

MDU28C-100B1

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC

MDU28C-100M

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC

MDU28C-100MD1

ACTIVE DELAY LINE, TRUE OUTPUT, DFP14, LOW PROFILE, SMD-14
DATADELAY

MDU28C-100MD4

DUAL, HCMOS-INTERFACED FIXED DELAY LINE
ETC