PLP75-1048G [BEL]

AC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT;
PLP75-1048G
型号: PLP75-1048G
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT

文件: 总6页 (文件大小:87K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PLP75 AC-DC Series Data Sheet  
75 Watts  
Features  
RoHS compliant for all six substances  
75 Watts with 5 CFM forced-air cooling  
Typical 80% efficiency  
65 Watts with convection cooling  
85-264 VAC wide-range input  
FCC & CISPR 22, Class "B" – Conducted EMI  
Power Factor Corrected (meets IEC61000-3-2)  
Typical 0.99 power factor  
Height meets 1U chassis constraints  
Two-year limited warranty  
Applications  
Safety Agency pending to UL60960-1, CSA 22.2No.  
60950-1-03, and TUV EN60950/IEC 60950-1  
Telecom, datacom  
Compliance with EN 61000-4-2 level 4 (ESD),  
EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast  
Transient/Burst), EN 61000-4-5 class 3 (Surge)  
Networking  
Industrial  
Medical instrumentation  
Consumer  
Gaming  
Description  
The PLP75 is a cost-effective and efficient series of AC-DC power supplies suited for telecom, datacom, and many  
other applications. The PLP75 Series meets the international information technology safety standards with the CE-  
Mark for the European Low Voltage Directive (LVD). Active power-factor-correction (PFC) is a standard feature.  
PFC enables the user to comply with EN 61000-3-2 line harmonics requirements. In addition, PFC reduces line  
losses and rms input current to help achieve low-cost operation and makes the end product more environmentally  
friendly to the end users.  
Single-Output Model Selection  
Model  
Nominal  
Output Voltage  
Min-Max Output  
Current (Amps),  
Convection  
Min-Max Output  
Current (Amps),  
Forced Air 1  
Peak Output  
Current  
Total  
Ripple &  
Noise  
Regulation  
(Amps) 2  
pk-pk % 4  
(%) 3  
(VDC)  
5
PLP75-1003G  
PLP75-1005G  
PLP75-1012G  
PLP75-1024G  
PLP75-1048G  
0.2 - 13  
0.2 - 13  
0.1 - 5.4  
0.1 - 2.7  
0.1 - 1.4  
0.2 - 15  
0.2 - 15  
0.1 - 6.5  
0.1 - 3.1  
0.1 - 1.6  
17.5  
16.5  
7
1
1
1
1
1
±2  
3.3  
5
±2  
±2  
±2  
±2  
5
5
12  
5
3.5  
1.8  
24  
5
48  
1
5 CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power  
supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side.  
2
Peak current duration for less than 30 seconds with a maximum duty cycle of 10%.  
3
At 25 °C ambient including voltage set point tolerance, line and load regulation  
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
4
5
Output is adjustable ±10 % of nominal.  
MCD10025 Rev. 1.0  
Page 1 of 6  
www.power-one.com  
PLP75 AC-DC Series Data Sheet  
75 Watts  
ELECTRICAL SPECIFICATIONS  
Input Specifications  
Parameter  
Conditions/Description  
Min.  
Nom.  
Max.  
Units  
AC Input Voltage  
Range  
Continuous voltage range  
85  
100 - 250  
264  
VAC  
DC Input Voltage  
Range  
Continuous voltage range;  
120  
47  
170  
250  
63  
VDC  
Hz  
For input above 250 VDC, consult factory.  
AC Input  
Frequency  
50 - 60  
Power Factor  
Complies with EN61000-3-2 Standard for Line  
Current Harmonics  
Input current  
Inrush current  
85 VAC at 75 W  
1.5  
Amps  
rms  
115 VAC, Max power, 25 °C  
230 VAC, Max power, 25 °C  
16  
32  
A pk  
A pk  
A
Input fuse  
Efficiency  
Non-user serviceable internally located AC  
input line fuse is provided.  
2.5  
At maximum output power, nominal line  
80  
%
MCD10025 Rev. 1.0  
Page 2 of 6  
www.power-one.com  
PLP75 AC-DC Series Data Sheet  
75 Watts  
Output Specifications  
Parameter  
Conditions/Description  
With convection cooling  
Min.  
Nom.  
Max.  
Units  
1
Output power  
Watts  
With 5 CFM forced-air cooling  
1
1
1
Output DC voltages  
Output DC current  
Minimum load  
Vo1 is adjustable ±10% of nominal.  
VDC  
A
No damage occurs to the power supply when  
operating at zero load.  
A
1
Output ripple & noise  
CM noise  
mV  
pk-pk  
50  
mV  
pk-pk  
Overshoot  
Vo1 overshoot at turn-on  
3
%
%
Load transient  
Vo1 deviation due to a 50 to 100%  
load change at a rate of 1A/µs  
±3  
Turn-On & Turn-Off  
characteristics  
Outputs turn ON monotonically.  
Turn-on time from AC  
ON  
Time required for output within regulation after  
initial application of AC input.  
0.2  
0.2  
20  
1.5  
20  
Sec  
ms  
ms  
Turn-on Delay  
Tme required for output voltage to rise from  
10% to 90%.  
Hold-up Time  
Time Vo1 is required to stay within 95%  
regulation after removal of AC measure from  
the last peak of the AC line at 115 VAC.  
Remote Sense  
Not available.  
Phase margin.  
Gain margin.  
Control loop stability  
45  
10  
Degrees  
dB  
1
See Model Selection tables.  
Fault Protection  
Parameter  
Conditions/Description  
Min.  
Nom.  
Max.  
Units  
Current Limit set point  
Overload protected - power limit.  
145  
% of  
peak  
rating  
Short-circuit protection  
OVP Trip  
Provided on all models.  
Vo1.  
115  
125  
135  
% of set  
point  
MCD10025 Rev. 1.0  
Page 3 of 6  
www.power-one.com  
PLP75 AC-DC Series Data Sheet  
75 Watts  
Isolation Requirements  
Parameter  
Conditions/Description  
Min.  
Nom.  
Max.  
Units  
Input-to-Chassis  
2121  
VDC  
Input-to-Output  
4242  
VDC  
VDC  
Output-to-Chassis  
Output-to-Output  
500  
1
1
All outputs share the same common.  
EMC Immunity  
Parameter  
Conditions/Description  
ESD  
EN 61000-4-2  
EN 61000-4-3  
Level 4.  
RF Susceptibility  
Fast Transient/Burst  
Surge  
Level 3.  
Level 3.  
Class 3.  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6.  
EN 61000-4-8.  
EN 61000-4-11.  
RF Immunity  
Magnetic Fields  
Voltage Interruptions  
EMC Emmisions  
Parameter  
Conditions/Description  
FCC Part 15  
Conducted Class B, Radiated Class A.  
CISPR 22  
Conducted Class B, Radiated Class A.  
and CISPR 11  
Environmental Specifications  
Parameter  
Conditions/Description  
Min.  
Nom.  
Max.  
Units  
Cooling  
Rated for convection and forced-air cooling.  
Audible Noise  
Operating Temp  
0
dBA  
ºC  
0 ºC to 70 ºC with linear derating to 50% above  
50 ºC. Unit will start-up at -20 ºC, but will not  
meet all published specifications.  
-20  
50  
70  
Altitude  
Operating.  
Non-Operating.  
10K  
50K  
ASL ft  
ASL ft  
Storage Temp  
Humidity  
-40  
85  
2.4  
6
ºC  
95% relative humidity @ 40 ºC, non-condensing  
Vibration  
Operating: Random vibration; 5 to 500 Hz  
(10 minutes, each axis).  
Grms  
Grms  
Non-Operating: Random vibration; 5 to 500 Hz  
(10 minutes, each axis).  
Shock  
Operating: half-sine, 11 ±3 ms, 3-axis.  
15  
40  
G
G
Non-Operating: half-sine, 11 ±3 ms, 3-axis.  
MCD10025 Rev. 1.0  
Page 4 of 6  
www.power-one.com  
PLP75 AC-DC Series Data Sheet  
75 Watts  
Regulatory & Safety Approvals  
Parameter  
Conditions/Description  
Min.  
Nom.  
Max.  
Units  
UL60950-1  
Approved.  
Approved.  
CSA-C22.2,  
No. 60950-1-03  
EN 60950-1  
Approved.  
/IEC 60950-1  
CE Mark for LVD  
CB Approval  
Approved.  
Approved.  
Ground Leakage  
Current  
At 230 VAC.  
1.4  
mA  
Mechanical Specifications  
Parameter  
Conditions/Description  
Min.  
Nom.  
Max.  
127  
76.2  
35  
Units  
mm  
Dimensions  
Length  
Width  
mm  
Height, including component or component lead  
protrusion on the bottom of the PCB.  
mm  
Power Density  
Mounting  
Input  
With forced-air cooling.  
4
W/cu in  
(Location/Hardware); see Outline Drawing.  
(Location/Connector);  
J1 - Molex 26-62-4030 or equivalent.  
Ground connector for  
plastic chassis  
Provided.  
Output  
(Location/Connector);  
J2 - Molex 26-60-4060 or equivalent.  
Outline Drawing  
Pins/Functions  
See Mechanical Drawing.  
Weight  
0.36  
kg  
in  
1
Mounting distance  
0.113  
Note  
1
The minimum distance from the bottom of the component leads (solder side) or top of the components (component side) to the customer's  
metal chassis should be at least 0.113 " (2.85 mm).  
MCD10025 Rev. 1.0  
Page 5 of 6  
www.power-one.com  
PLP75 AC-DC Series Data Sheet  
75 Watts  
Mechanical Drawing  
J1 - AC CONN.  
Pin 1  
Pin 2  
Pin 3  
NEUTRAL  
missing pin  
LINE  
5.00 +/- 02  
4.55  
Ø 0.16 (4 places)  
J2 - DC CON  
safety ground  
connection point  
Pin 1*  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Vo1  
Vo1  
Pin #1  
Vo1  
safety ground connection point  
DC COM  
DC COM  
DC COM  
J2 - DC output  
J1 input  
connector  
connector  
(see pin-out  
table)  
3.00  
+/-.02  
Pin #1  
2.55  
TOP VIEW  
fastener  
clearance area 4  
places)  
0.06  
1.2  
END VIEW  
SIDE VIEW  
1.37  
+/-.02  
Printed Circuit Board  
0.1  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent  
of the respective divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
MCD10025 Rev. 1.0  
Page 6 of 6  
www.power-one.com  

相关型号:

PLP75-3000G

AC-DC power supplies suited for telecom
POWER-ONE

PLP75-3001G

AC-DC power supplies suited for telecom
POWER-ONE

PLP75-3003G

AC-DC power supplies suited for telecom
POWER-ONE

PLP75-3300G

AC-DC power supplies suited for telecom
POWER-ONE

PLP75-3301G

AC-DC power supplies suited for telecom
POWER-ONE

PLPV811DBVT

Nanopower Operational Amplifiers
TI

PLPV812DGKT

Dual Channel Precision 425nA Nanopower Operational Amplifiers 8-VSSOP -40 to 125
TI

PLQ

RF PLL Synthesizer
RALTRON

PLQ08

FAST RECOVERY RECTIFIER DIODES
STMICROELECTR

PLQ08RL

1A, 80V, SILICON, SIGNAL DIODE
STMICROELECTR

PLQ1

FAST RECOVERY RECTIFIER DIODES
STMICROELECTR

PLQ16L8-5A

Fuse-Programmable PLD
ETC