PLP75 AC-DC Series Data Sheet
75 Watts
Features
•
•
RoHS compliant for all six substances
75 Watts with 5 CFM forced-air cooling
Typical 80% efficiency
•
•
•
•
•
•
•
•
•
65 Watts with convection cooling
85-264 VAC wide-range input
FCC & CISPR 22, Class "B" – Conducted EMI
Power Factor Corrected (meets IEC61000-3-2)
Typical 0.99 power factor
Height meets 1U chassis constraints
Two-year limited warranty
Applications
Safety Agency pending to UL60960-1, CSA 22.2No.
60950-1-03, and TUV EN60950/IEC 60950-1
•
•
•
•
•
•
Telecom, datacom
•
Compliance with EN 61000-4-2 level 4 (ESD),
EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast
Transient/Burst), EN 61000-4-5 class 3 (Surge)
Networking
Industrial
Medical instrumentation
Consumer
Gaming
Description
The PLP75 is a cost-effective and efficient series of AC-DC power supplies suited for telecom, datacom, and many
other applications. The PLP75 Series meets the international information technology safety standards with the CE-
Mark for the European Low Voltage Directive (LVD). Active power-factor-correction (PFC) is a standard feature.
PFC enables the user to comply with EN 61000-3-2 line harmonics requirements. In addition, PFC reduces line
losses and rms input current to help achieve low-cost operation and makes the end product more environmentally
friendly to the end users.
Single-Output Model Selection
Model
Nominal
Output Voltage
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air 1
Peak Output
Current
Total
Ripple &
Noise
Regulation
(Amps) 2
pk-pk % 4
(%) 3
(VDC)
5
PLP75-1003G
PLP75-1005G
PLP75-1012G
PLP75-1024G
PLP75-1048G
0.2 - 13
0.2 - 13
0.1 - 5.4
0.1 - 2.7
0.1 - 1.4
0.2 - 15
0.2 - 15
0.1 - 6.5
0.1 - 3.1
0.1 - 1.6
17.5
16.5
7
1
1
1
1
1
±2
3.3
5
±2
±2
±2
±2
5
5
12
5
3.5
1.8
24
5
48
1
5 CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power
supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side.
2
Peak current duration for less than 30 seconds with a maximum duty cycle of 10%.
3
At 25 °C ambient including voltage set point tolerance, line and load regulation
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4
5
Output is adjustable ±10 % of nominal.
MCD10025 Rev. 1.0
Page 1 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet
75 Watts
ELECTRICAL SPECIFICATIONS
Input Specifications
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
AC Input Voltage
Range
Continuous voltage range
85
100 - 250
264
VAC
DC Input Voltage
Range
Continuous voltage range;
120
47
170
250
63
VDC
Hz
For input above 250 VDC, consult factory.
AC Input
Frequency
50 - 60
Power Factor
Complies with EN61000-3-2 Standard for Line
Current Harmonics
Input current
Inrush current
85 VAC at 75 W
1.5
Amps
rms
115 VAC, Max power, 25 °C
230 VAC, Max power, 25 °C
16
32
A pk
A pk
A
Input fuse
Efficiency
Non-user serviceable internally located AC
input line fuse is provided.
2.5
At maximum output power, nominal line
80
%
MCD10025 Rev. 1.0
Page 2 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet
75 Watts
Output Specifications
Parameter
Conditions/Description
With convection cooling
Min.
Nom.
Max.
Units
1
Output power
Watts
With 5 CFM forced-air cooling
1
1
1
Output DC voltages
Output DC current
Minimum load
Vo1 is adjustable ±10% of nominal.
VDC
A
No damage occurs to the power supply when
operating at zero load.
A
1
Output ripple & noise
CM noise
mV
pk-pk
50
mV
pk-pk
Overshoot
Vo1 overshoot at turn-on
3
%
%
Load transient
Vo1 deviation due to a 50 to 100%
load change at a rate of 1A/µs
±3
Turn-On & Turn-Off
characteristics
Outputs turn ON monotonically.
Turn-on time from AC
ON
Time required for output within regulation after
initial application of AC input.
0.2
0.2
20
1.5
20
Sec
ms
ms
Turn-on Delay
Tme required for output voltage to rise from
10% to 90%.
Hold-up Time
Time Vo1 is required to stay within 95%
regulation after removal of AC measure from
the last peak of the AC line at 115 VAC.
Remote Sense
Not available.
Phase margin.
Gain margin.
Control loop stability
45
10
Degrees
dB
1
See Model Selection tables.
Fault Protection
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
Current Limit set point
Overload protected - power limit.
145
% of
peak
rating
Short-circuit protection
OVP Trip
Provided on all models.
Vo1.
115
125
135
% of set
point
MCD10025 Rev. 1.0
Page 3 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet
75 Watts
Isolation Requirements
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
Input-to-Chassis
2121
VDC
Input-to-Output
4242
VDC
VDC
Output-to-Chassis
Output-to-Output
500
1
1
All outputs share the same common.
EMC Immunity
Parameter
Conditions/Description
ESD
EN 61000-4-2
EN 61000-4-3
Level 4.
RF Susceptibility
Fast Transient/Burst
Surge
Level 3.
Level 3.
Class 3.
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6.
EN 61000-4-8.
EN 61000-4-11.
RF Immunity
Magnetic Fields
Voltage Interruptions
EMC Emmisions
Parameter
Conditions/Description
FCC Part 15
Conducted Class B, Radiated Class A.
CISPR 22
Conducted Class B, Radiated Class A.
and CISPR 11
Environmental Specifications
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
Cooling
Rated for convection and forced-air cooling.
Audible Noise
Operating Temp
0
dBA
ºC
0 ºC to 70 ºC with linear derating to 50% above
50 ºC. Unit will start-up at -20 ºC, but will not
meet all published specifications.
-20
50
70
Altitude
Operating.
Non-Operating.
10K
50K
ASL ft
ASL ft
Storage Temp
Humidity
-40
85
2.4
6
ºC
95% relative humidity @ 40 ºC, non-condensing
Vibration
Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
Grms
Grms
Non-Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
Shock
Operating: half-sine, 11 ±3 ms, 3-axis.
15
40
G
G
Non-Operating: half-sine, 11 ±3 ms, 3-axis.
MCD10025 Rev. 1.0
Page 4 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet
75 Watts
Regulatory & Safety Approvals
Parameter
Conditions/Description
Min.
Nom.
Max.
Units
UL60950-1
Approved.
Approved.
CSA-C22.2,
No. 60950-1-03
EN 60950-1
Approved.
/IEC 60950-1
CE Mark for LVD
CB Approval
Approved.
Approved.
Ground Leakage
Current
At 230 VAC.
1.4
mA
Mechanical Specifications
Parameter
Conditions/Description
Min.
Nom.
Max.
127
76.2
35
Units
mm
Dimensions
Length
Width
mm
Height, including component or component lead
protrusion on the bottom of the PCB.
mm
Power Density
Mounting
Input
With forced-air cooling.
4
W/cu in
(Location/Hardware); see Outline Drawing.
(Location/Connector);
J1 - Molex 26-62-4030 or equivalent.
Ground connector for
plastic chassis
Provided.
Output
(Location/Connector);
J2 - Molex 26-60-4060 or equivalent.
Outline Drawing
Pins/Functions
See Mechanical Drawing.
Weight
0.36
kg
in
1
Mounting distance
0.113
Note
1
The minimum distance from the bottom of the component leads (solder side) or top of the components (component side) to the customer's
metal chassis should be at least 0.113 " (2.85 mm).
MCD10025 Rev. 1.0
Page 5 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet
75 Watts
Mechanical Drawing
J1 - AC CONN.
Pin 1
Pin 2
Pin 3
NEUTRAL
missing pin
LINE
5.00 +/- 02
4.55
Ø 0.16 (4 places)
J2 - DC CON
safety ground
connection point
Pin 1*
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Vo1
Vo1
Pin #1
Vo1
safety ground connection point
DC COM
DC COM
DC COM
J2 - DC output
J1 input
connector
connector
(see pin-out
table)
3.00
+/-.02
Pin #1
2.55
TOP VIEW
fastener
clearance area 4
places)
0.06
1.2
END VIEW
SIDE VIEW
1.37
+/-.02
Printed Circuit Board
0.1
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent
of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
MCD10025 Rev. 1.0
Page 6 of 6
www.power-one.com
相关型号:
©2020 ICPDF网 联系我们和版权申明