SQE48T20120-PDAKG [BEL]

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ROHS COMPLIANT, ONE-EIGHTH BRICK PACKAGE-5;
SQE48T20120-PDAKG
型号: SQE48T20120-PDAKG
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ROHS COMPLIANT, ONE-EIGHTH BRICK PACKAGE-5

文件: 总13页 (文件大小:641K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
eatures  
RoHS lead-free solder and lead-solder-exempted  
products are available  
Industry-standard quarter-brick pin-out  
Delivers 240W at 94.5% efficiency  
Withstands 100V input transient for 100ms  
Fixed-frequency operation  
On-board input differential LC-filter  
Start-up into pre-biased load  
No minimum load required  
Meets Basic Insulation requirements  
Fully protected (OTP, OCP, OVP, UVLO)  
Positive or negative logic ON/OFF option  
Low height of 0.44” (11.18mm)  
Weight: 33.3g  
Applications  
Intermediate Bus Architectures  
Data communications/processing  
LAN/WAN  
High reliability: MTBF = 14.3 million hours,  
Servers, Workstations  
calculated per Telcordia SR-332, Method I Case 1  
Safety according to IEC/EN 60950-1 2nd Edition and  
Benefits  
UL/CSA 60950-1 2nd Edition  
High efficiency no heat sink required 1  
Designed to meet Class B conducted emissions per  
FCC and EN55022 when used with external filter  
Industry-standard 1/8th brick footprint: 0.896” x  
2.30” (2.06 in2) - 38% smaller than conventional  
quarter-bricks  
All materials meet UL94, V-0 flammability rating  
Description  
The new iPWERTM high-performance 20A SQE48T20120 DC-DC converter provides a high efficiency single  
output, in a 1/8th brick package that is only 62% the size of the industry-standard quarter-brick. Specifically  
designed for operation in systems that have limited airflow and increased ambient temperatures, the  
SQE48T20120 converter utilizes the same pin-out and Input/Output functionality of the industry-standard quarter-  
bricks. In addition, a heat spreader feature is available (-xxxBx suffix) that provides an effective thermal interface  
for coldplate and heat sinking options.  
The SQE48T20120 converter thermal performance is accomplished through the use of patented/patent-pending  
circuits, packaging, and processing techniques to achieve ultra-high efficiency, excellent thermal management,  
and a low-body profile.  
Low-body profile and the preclusion of heat sinks minimize impedance to system airflow, thus enhancing cooling  
for both upstream and downstream devices. The use of 100% automation for assembly, coupled with advanced  
electronic circuits and thermal design, results in a product with extremely high reliability.  
Operating from a wide-range 36-75V input, the iPWER SQE48T20120 converter provides a fully regulated 12V  
output voltage. Employing a standard power pin-out, the SQE48T20120 converter is an ideal drop-in replacement  
for existing high current eighth-brick and quarter-brick designs. Inclusion of this converter in a new design can  
result in significant board space and cost savings. The designer can expect reliability improvement over other  
available converters because of the SQE48T20120‟s optimized thermal efficiency.  
1
Baseplate/heat spreader option (suffix „-xxxBx‟) facilitates heatsink mounting to further enhance the unit‟s thermal capability.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 1 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Electrical Specifications  
Conditions: TA = 25 ºC, Airflow = 300 LFM (1.5 m/s), Vin = 48 VDC, Cin=100 µF, unless otherwise specified.  
Parameter  
Notes  
Min  
Typ  
Max Units  
Absolute Maximum Ratings  
Input Voltage  
Continuous  
Transient (100ms)  
-0.3  
80  
100  
85  
VDC  
VDC  
°C  
Operating Temperature  
-40  
-40  
-40  
Ambient (TA)  
(Note: 1) Component (TC)  
Baseplate (TB)  
125  
105  
°C  
°C  
(See Derating Curves)  
Storage Temperature  
Isolation Characteristics  
I/O Isolation  
-55  
2,250  
10  
125  
°C  
VDC  
pF  
Isolation Capacitance  
Isolation Resistance  
w/o In/Out capacitor (suffix -xxx0x)  
200  
MΩ  
I/O Isolation  
1,500  
10  
VDC  
pF  
with In/Out capacitor (suffix -xxxKx)  
Isolation Capacitance  
Isolation Resistance  
1,200  
1,500  
MΩ  
Input to Baseplate  
1,500  
1,500  
VDC  
VDC  
w/o In/Out capacitor (suffix -xxxBx)  
Output to Baseplate  
Feature Characteristics  
Switching Frequency  
Output Voltage Trim Range 2  
Remote Sense Compensation 2  
Output Overvoltage Protection (Non-latching)  
450  
n/a  
kHz  
%
n/a  
%
110  
120  
130  
300  
130  
%
(Note: 1) Component (TC)  
Over Temperature Shutdown  
(Non-latching)  
°C  
ms  
Auto-Restart Period  
Applies to all protection features  
Turn-On Time from Vin  
Time from UVLO to Vo=90%VOUT(NOM)  
Resistive load  
Time from ON to Vo=90%VOUT(NOM)  
Resistive load  
Time from UVLO to Vo=90%VOUT(NOM)  
Resistive load, CEXT=10,000µF load  
Time from ON to Vo=90%VOUT(NOM)  
10  
10  
12  
12  
ms  
ms  
ms  
ms  
Turn-On Time from ON/OFF Control  
Turn-On Time from Vin  
(w/ Co max.)  
Turn-On Time from ON/OFF Control  
(w/ Co max.) Resistive load, CEXT=10,000µF load  
ON/OFF Control (Positive Logic)  
Converter Off (logic low)  
Converter On (logic high)  
Converter Off (logic low)  
Converter On (logic high)  
-20  
2.4  
2.4  
-20  
0.8  
20  
VDC  
VDC  
VDC  
VDC  
ON/OFF Control (Negative Logic)  
20  
0.8  
Additional Notes:  
1
Reference Figure E for component (TC and TB) locations.  
This functionality not provided, however the unit is fully regulated.  
2
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 2 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Electrical Specifications (continued)  
Conditions: TA = 25 ºC, Airflow = 300 LFM (1.5 m/s), Vin = 48 VDC, Cin=100 µF, unless otherwise specified.  
Parameter  
Input Characteristics  
Notes  
Min  
Typ  
Max Units  
Operating Input Voltage Range  
Input Undervoltage Lockout  
Turn-on Threshold  
36  
48  
75  
VDC  
33  
31  
34.5  
33  
35.5  
34.5  
VDC  
VDC  
VDC  
ADC  
mA  
Turn-off Threshold  
Lockout Hysteresis Voltage  
Maximum Input Current  
Input Standby Current  
1.0  
2.0  
Po = 240W @ 36VDC In  
Vin = 48V, converter disabled  
Vin = 48V, converter enabled  
7.1  
20  
14  
80  
Input No Load Current (No load on the output)  
mA  
400  
130  
25  
550 mAPK-PK  
Input Reflected-Ripple Current, ic  
250  
50  
20  
mARMS  
mAPK-PK  
mARMS  
dB  
Vin = 48V, 25 MHz bandwidth,  
Po=240W (Fig. 10)  
Input Reflected-Ripple Current, iS  
10  
Input Voltage Ripple Rejection  
Output Characteristics  
Output Voltage Setpoint  
Output Regulation  
120 Hz  
45  
11.76  
11.64  
12.00 12.24  
VDC  
VIN=48V, IOUT=0Amps, TA=25°C  
Over Line  
±12  
±6  
±24  
±12  
mV  
mV  
IOUT=20Amps, TA=25°C  
VIN=48V, , TA=25°C  
Over Load  
Output Voltage Range  
Over line, load and temperature  
12.36  
VDC  
50  
25  
100 mVPK-PK  
IOUT=20Amps,  
CEXT =10 µF tantalum + 1 µF ceramic  
Output Ripple and Noise 25 MHz bandwidth  
50  
VRMS  
IOUT=20Amps (resistive)  
CEXT  
ESR  
0 1  
1
10,000  
µF  
Admissible External Load Capacitance  
mOhm  
Output Current Range  
Current Limit Inception  
RMS Short-Circuit Current  
Dynamic Response  
0
20  
28  
ADC  
ADC  
ARMS  
Non-latching  
20.5  
25  
10  
Non-latching Short = 10 mΩ  
12.5  
Load Change 50%-75%-50% of IOUT Max  
75  
30  
140  
50  
mV  
µs  
CEXT = 10µF tantalum + 1µF ceramic  
48VIN, TA=25°C, 300LFM  
(di/dt = 0.1 A/μs)  
Settling Time to 1% of VOUT  
Efficiency  
%
%
@ 100% Load  
94.5  
95  
@ 50% Load  
Additional Notes:  
1
See “Input & Output Impedance”, Page 4.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 3 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Environment and Mechanical Specifications  
Environmental  
Operating Humidity  
Storage Humidity  
Mechanical  
Weight  
Non-condensing  
Non-condensing  
95  
95  
%
%
33.3  
Vibration  
GR-63-CORE, Sect. 5.4.2  
Half Sinewave, 3-axis  
1
g
g
Shocks  
50  
Reliability  
Telcordia SR-332, Method I Case 1  
50% electrical stress, 40°C components  
MTBF  
14.3  
MHrs  
EMI and Regulatory Compliance  
Conducted Emissions  
CISPR 22 B with external EMI filter network  
Operations  
Input and Output Impedance  
These power converters have been designed to be  
stable with no external capacitors when used in low  
inductance input and output circuits.  
However, in some applications, the inductance  
associated with the distribution from the power  
source to the input of the converter can affect the  
stability of the converter. A 100 µF tantalum  
capacitor with an ESR < 1 across the input is  
recommended to ensure stability of the converter  
overall operating conditions.  
Fig. A: Typ. Circuit configuration for ON/OFF function.  
The positive logic version turns on when the ON/OFF  
pin is at logic high and turns off when at logic low.  
The converter is on when the ON/OFF pin is left  
open. See the Electrical Specifications for logic  
high/low definitions.  
In many end applications, a high capacitance value  
is applied to the converter‟s output via distributed  
decoupling capacitors. The power converter will  
exhibit stable operation with external load  
capacitance up to 10,000 µF.  
The negative logic version turns on when the pin is  
at logic low and turns off when the pin is at logic  
high. The ON/OFF pin can be hard wired directly to  
Vin(-) to enable automatic power up of the converter  
without the need of an external control signal.  
ON/OFF (Pin 2)  
The ON/OFF pin is used to turn the power converter  
on or off remotely via a system signal. There are two  
remote control options available, positive and  
negative logic, with both referenced to Vin(-). A  
typical connection is shown in Figure A.  
The ON/OFF pin is internally pulled up to 5V through  
a resistor. A properly de-bounced mechanical switch,  
open-collector transistor, or FET can be used to  
drive the input of the ON/OFF pin. The device must  
be capable of sinking up to 0.2 mA at a low level  
voltage of 0.8 V. An external voltage source (±20 V  
maximum) may be connected directly to the ON/OFF  
input, in which case it must be capable of sourcing or  
sinking up to 1 mA depending on the signal polarity.  
See the Startup Information section for system timing  
waveforms associated with use of the ON/OFF pin.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 4 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Safety Requirements  
Protection Features  
The converters meet North American and  
International safety regulatory requirements. Basic  
Input Undervoltage Lockout (UVLO)  
Input undervoltage lockout is standard with this  
converter. The converter will shut down when the  
input voltage drops below a pre-determined voltage.  
Insulation is provided between input and output.  
The converters have no internal fuse. If required, the  
external fuse needs to be provided to protect the  
converter from catastrophic failure. Refer to the  
“Input Fuse Selection for DC/DC converters”  
application note on www.power-one-com for proper  
selection of the input fuse. Both input traces and the  
chassis ground trace (if applicable) must be capable  
of conducting a current of 1.5 times the value of the  
fuse without opening. The fuse must not be placed  
in the grounded input line.  
The input voltage must be typically 35V for the  
converter to turn on. Once the converter has been  
turned on, it will shut off when the input voltage  
drops typically below 33V. This feature is beneficial  
in preventing deep discharging of batteries used in  
telecom applications.  
Output Overcurrent Protection (OCP)  
The converter is protected against overcurrent or  
short circuit conditions. Upon sensing an overcurrent  
condition, the converter will shut down.  
Abnormal and component failure tests were  
conducted with the input protected by a 10A fuse. If  
a fuse rated greater than 10A is used, additional  
testing may be required. To protect a group of  
converters with a single fuse, the rating can be  
increased from the recommended value above.  
Once this occurs, it will enter hiccup mode and  
attempt to restart approximately every 300 ms with  
an approximate duty cycle of 5%. The attempted  
restart will continue indefinitely until the overload or  
short circuit condition is removed.  
Once the output current is brought back into its  
specified range, the converter automatically exits the  
hiccup mode and resumes normal operation  
Electromagnetic Compatibility (EMC)  
EMC requirements must be met at the end-product  
system level, as no specific standards dedicated to  
EMC characteristics of board mounted component  
dc-dc converters exist. However, Power-One tests its  
converters to several system level standards,  
primary of which is the more stringent EN55022,  
Output Overvoltage Protection (OVP)  
The converter will shut down if the output voltage  
across Vout(+) and Vout(-) exceeds the threshold of  
the OVP circuitry. The OVP circuitry contains its own  
reference, independent of the output voltage  
regulation loop. Once the converter has shut down, it  
will attempt to restart every 300 ms until the OVP  
condition is removed.  
Information  
technology  
equipment  
-
Radio  
disturbance characteristics - Limits and methods of  
measurement.  
An effective internal LC differential filter significantly  
reduces input reflected ripple current, and improves  
EMC.  
Overtemperature Protection (OTP)  
With the addition of a simple external filter, the  
SQE48T20120 converter will pass the requirements  
of Class B conducted emissions per EN55022 and  
FCC requirements. Refer to Figures 14 15 for  
typical performance with external filter.  
The converter will shut down under an  
overtemperature condition to protect itself from  
overheating caused by operation outside the thermal  
derating curves, or operation in abnormal conditions  
such as system fan failure. The converter will  
automatically restart after it has cooled to a safe  
operating temperature.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 5 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Startup Information (using negative ON/OFF)  
Scenario #1: Initial Startup From Bulk Supply  
VIN  
ON/OFF function enabled, converter started via application  
of VIN. See Figure B.  
ON/OFF  
STATE  
Time  
t0  
Comments  
ON/OFF pin is ON; system front-end power is  
toggled on, VIN to converter begins to rise.  
VIN crosses undervoltage Lockout protection  
circuit threshold; converter enabled.  
Converter begins to respond to turn-on  
command (converter turn-on delay).  
OFF  
ON  
t1  
t2  
t3  
VOUT  
Converter VOUT reaches 100% of nominal value.  
For this example, the total converter startup time (t3- t1) is  
typically 12 ms.  
t
t0  
t1 t2  
t3  
Fig. B: Startup scenario #1.  
Scenario #2: Initial Startup Using ON/OFF Pin  
With VIN previously powered, converter started via  
ON/OFF pin. See Figure C.  
VIN  
Time  
t0  
t1  
Comments  
VINPUT at nominal value.  
Arbitrary time when ON/OFF pin is enabled  
(converter enabled).  
t2  
t3  
End of converter turn-on delay.  
Converter VOUT reaches 100% of nominal value.  
ON/OFF  
STATE  
OFF  
ON  
For this example, the total converter startup time (t3- t1) is  
typically 12 ms.  
VOUT  
Scenario #3: Turn-off and Restart Using ON/OFF Pin  
With VIN previously powered, converter is disabled and  
then enabled via ON/OFF pin. See Figure D.  
Time  
t0  
Comments  
t
VIN and VOUT are at nominal values; ON/OFF pin  
ON.  
t0  
t1 t2  
t3  
t1  
ON/OFF pin arbitrarily disabled; converter  
output falls to zero; turn-on inhibit delay period  
(300 ms typical) is initiated, and ON/OFF pin  
action is internally inhibited.  
Fig. C: Startup scenario #2.  
t2  
ON/OFF pin is externally re-enabled.  
If (t2- t1) ≤ 300 ms, external action of  
ON/OFF pin is locked out by startup inhibit  
timer.  
If (t2- t1) > 300 ms, ON/OFF pin action is  
internally enabled.  
t3  
Turn-on inhibit delay period ends. If ON/OFF pin  
is ON, converter begins turn-on; if off, converter  
awaits ON/OFF pin ON signal; see Figure F.  
End of converter turn-on delay.  
t4  
t5  
Converter VOUT reaches 100% of nominal value.  
For the condition, (t2- t1) ≤ 300 ms, the total converter  
startup time (t5- t1) is typically 312ms. For (t2- t1) > 300 ms,  
startup will be typically 125ms after release of ON/OFF pin.  
Fig. D: Startup scenario #3.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 6 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Characterization  
General Information  
temperature of 125°C as indicated by the thermal  
measurement  
The converter has been characterized for many  
operational aspects, to include thermal derating  
(maximum load current as a function of ambient  
temperature and airflow), efficiency, startup and  
shutdown parameters, output ripple and noise,  
transient response to load step-change, overcurrent,  
and short circuit.  
(ii) The output current at which the temperature at  
the thermocouple locations TC and TC1 do not exceed  
125°C and 110°C respectively. (Figure E)  
(iii) The nominal rating of the converter (20A/240W).  
The following pages contain specific plots or  
waveforms associated with the converter. Additional  
comments for specific data are provided below.  
Thermocouples (TC)  
TC1  
Test Conditions  
All data presented were taken with the converter  
soldered to a test board, specifically a 0.060” thick  
printed wiring board (PWB) with four layers. The top  
and bottom layers were not metalized. The two inner  
layers, comprised of two-ounce copper, were used to  
provide traces for connectivity to the converter.  
Thermocouple (TB)  
Area  
The lack of metallization on the outer layers as well  
as the limited thermal connection ensured that heat  
transfer from the converter to the PWB was  
minimized. This provides a worst-case but consistent  
scenario for thermal derating purposes.  
Fig. E: Locations of the thermocouples for thermal testing.  
Thermal Derating Baseplate Cooled (p/n: -xGxBx)  
All measurements requiring airflow were made in the  
vertical and horizontal wind tunnel using Infrared (IR)  
thermography and thermocouples for thermometry.  
The maximum load current rating vs. baseplate  
temperature is provided in Figure 5.  
The ambient temperature was maintained 85°C,  
with an airflow rate of 30LFM (0.15m/s).  
Ensuring components on the converter do not  
exceed their ratings is important to maintaining high  
reliability. If one anticipates operating the converter  
at or close to the maximum loads specified in the  
derating curves, it is prudent to check actual  
Thermocouple measurements were maximized, as  
above, to the following limits:  
TC 125°C, TC1 110°C & TB 105°C.  
The user should design for TB 105°C.  
operating  
temperatures  
in  
the  
application.  
Thermographic imaging is preferable; if this  
capability is not available, then thermocouples may  
be used. The use of AWG #36 gauge thermocouples  
is recommended to ensure measurement accuracy.  
Careful routing of the thermocouple leads will further  
minimize measurement error. Refer to Figure E for  
the optimum measuring thermocouple location.  
Efficiency  
Figure 6 shows the efficiency vs. load current plot for  
ambient temperature (TA) of 25ºC, airflow rate of  
300LFM (1.5m/s) with vertical mounting and input  
voltages of 36V, 48V, 65V and 75V.  
Power Dissipation  
Figure 7 shows the power dissipation vs. load  
current plot for TA=25ºC, airflow rate of 300LFM  
(1.5m/s) with vertical mounting and input voltages of  
36V, 48V, 65V and 75V.  
Thermal Derating Air Cooled  
Load current vs. ambient temperature and airflow  
rates are given in Figures 2 - 4. Ambient temperature  
was varied between 25°C and 85°C, with airflow  
rates from 30 to 500LFM (0.15 to 2.5m/s).  
Startup  
For each set of conditions, the maximum load  
current was defined as the lowest of:  
Output voltage waveforms, during the turn-on  
transient using the ON/OFF pin for full rated load  
currents (resistive load) are shown with and without  
external load capacitance in and, respectively.  
(i) The output current at which any FET junction  
temperature does not exceed  
a
maximum  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 7 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
iS  
iC  
Ripple and Noise  
H  
source  
inductance  
1
1 F  
Ceramic  
10 F  
Tantalum  
Capacitor  
SQE 48  
100F  
ESR < 1  
electrolytic  
capacitor  
Figure 11 shows the output voltage ripple waveform,  
measured at full rated load current with a 10µF  
tantalum and a 1µF ceramic capacitor across the  
output. Note that all output voltage waveforms are  
measured across the 1µF ceramic capacitor.  
+
DC -DC  
Converter  
Vout  
V source  
Figure 1. Test setup for measuring input reflected ripple  
The input reflected-ripple current waveforms are  
obtained using the test setup shown in Figure 1. The  
corresponding waveforms are shown in Figure 12 and  
Figure 13.  
currents, ic and is.  
Figure 2. Available load current vs. ambient air temperature  
and airflow rates for SQE48T20120 converter  
Figure 4. Power derating of SQE48T20120 converter with  
baseplate option and 0.91” tall horizontal-fin  
heatsink. (Conditions: same as Fig. 2)  
mounted vertically with air flowing from pin 3 to  
pin 1, MOSFET temperature 125 C, Vin = 48 V.  
Figure 3. Power derating of SQE48T20120 converter with  
baseplate option and 0.25” tall horizontal-fin  
heatsink. (Conditions: same as Fig. 2)  
Figure 5. Power derating of SQE48T20120 converter with  
baseplate option and coldplate cooling.  
(Conditions: TB ≤ 105°C, TA ≤ 85°C,  
Air velocity ≤ 30LFM (≤ 0.15m/s), Vin = 48 V.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 8 of 13  
 
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Figure 6. Efficiency vs. load current and input voltage for  
Figure 8. Turn-on waveform at full rated load current  
SQE48T20120 converter mounted vertically with air  
flowing from pin 3 to pin 1 at 300 LFM (1.5 m/s) and  
TA = 25C.  
(resistive) with 10,000 uF output capacitor at Vin =  
48V, triggered via ON/OFF pin. Top trace: ON/OFF  
signal (10V/div.). Bottom trace: Output voltage  
(2V/div.). Time scale: 5ms/div.  
Figure 7. Power dissipation vs. load current and input  
voltage for SQE48T20120 converter mounted  
vertically with air flowing from pin 3 to pin 1 at  
300 LFM (1.5 m/s) and TA = 25C.  
Figure 9. Turn-on waveform at full rated load current  
(resistive) with 10uF tant. + 1uF cer. output  
capacitor at Vin = 48V, triggered via ON/OFF pin.  
Top trace: ON/OFF signal (10V/div.). Bottom trace:  
Output voltage (2V/div.). Time scale: 5ms/div.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 9 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Figure 10. Output voltage response to load current step-  
change (10A 15A 10A) at Vin = 48 V.  
Top trace: output voltage (100mV/div.)  
Bottom: load current (5A/div.).  
Figure 12. Input reflected-ripple current, i (50 mA/div.),  
s
measured through 1 µH at the source at full rated  
load current and Vin = 48 V. Refer to Figure 1 for  
test setup. Time scale: 1 µs/div.  
Current slew rate: 0.1 A/µs. Time scale: 0.1ms/div.  
Co = 10µF tantalum + 1µF ceramic  
Figure 11. Output voltage ripple (50 mV/div.) at full rated  
load current into a resistive load with Co = 10µF  
tantalum + 1µF ceramic and Vin = 48V. Time  
scale: 1µs/div.  
Figure 13. Input reflected ripple-current, i (200 mA/div.),  
c
measured at input terminals at full rated load  
current and Vin = 48 V. Refer to Figure 1 for  
test setup. Time scale: 1 µs/div.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 10 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Comp.  
Des.  
Description  
C1, C2,  
C6  
C3  
L1, L2  
C4, C5  
(2EA, 6 capacitors)  
1uF, 100V ceramic cap  
33uF, 100V electrolytic cap  
0.59mH, Pulse P0353NL  
2,200Pf, ceramic cap  
Figure 14. Typical input EMI filter circuit to attenuate conducted emissions.  
Figure 15. Input conducted emissions measurement (Typ.) of SQE48T20120.  
Conditions: VIN=48VDC, IOUT = 20AMPS  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 11 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Physical Information  
SQE48T Pinout (Through-hole)  
2.300±0.020 [58.42±0.51]  
PIN SHOULDER  
Ø0.096±0.002 [Ø2.44±0.05] 2X  
PIN SHOULDER  
Pad/Pin Connections  
PIN Ø0.040±0.002 [Ø1.02±0.05] 3X  
Ø0.076±0.002 [Ø1.93±0.05] 3X  
Pad/Pin #  
Function  
1
2
3
5
0.896±0.020 [22.76±0.51]  
0.600 [15.24]  
0.300 [7.62]  
0.300 [7.62]  
1
2
3
4
5
VIN (+)  
TOP VIEW  
4
ON/OFF  
VIN (-)  
VOUT (-)  
VOUT (+)  
2.000 [50.80]  
0.148±0.020 [3.76±0.51]  
PIN Ø0.062±0.002 [Ø1.57±0.05] 2X  
0.145±0.020 [3.68±0.51]  
SQE48T Platform Notes  
SIDE VIEW  
NO HEAT SPREADER  
All dimensions are in inches [mm]  
Pins 1-3 are Ø 0.040” [1.02]  
with Ø 0.076” [1.93] shoulder  
Pins 4 and 5 are Ø 0.062” [1.57]  
with are Ø 0.096” [2.44] shoulder  
Pin Material: Brass Alloy 360  
Pin Finish: Tin over Nickel  
HT (-xDx0x, -xDxKx)  
PL  
CL  
CUSTOMER PCB  
SIDE VIEW  
WITH HEAT SPREADER  
HT (-xDxBx)  
CL  
CUSTOMER PCB  
PL  
Min  
Clearance  
[CL]  
Pin Length  
[PL]  
±0.005[±0.13]  
Height  
[HT]  
Special  
Features  
Pin  
Option  
0.440[11.18]  
0.028”  
[0.71]  
0
K
A
B
0.188[4.78]  
0.145[3.68]  
Max  
D
0.500+/-0.020  
[12.70 +/-0.51]  
0.028”  
[0.71]  
B
Heat Spreader Interface Information  
DEPTH NOTE:  
SCREW LENGTH MUST BE SELECTED TO LIMIT HEAT  
SPREADER PENETRATION TO 0.08 [2.0]  
2.300±0.020 [58.42±0.51]  
2.000 [50.80]  
M3 X .5 2X  
SEE DEPTH NOTE  
PIN 1 INDICATOR  
0.896±0.020 [22.76±0.51]  
0.600 [15.24]  
0.148 [3.76]  
TOP VIEW  
0.150 [3.81]  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 12 of 13  
SQE48T20120 DC-DC Converter Data Sheet  
36-75 VDC Input; 12 VDC @ 20A Output  
Converter Part Numbering/Ordering Information  
Maximum  
Height  
[HT]  
Pin  
Length  
[PL]  
Product Input Mounting Rated Output  
Series Voltage Scheme Current Voltage  
ON/OFF  
Logic  
Special  
Features  
RoHS  
G
SQE  
48  
T
20  
120  
-
N
D
A
B
0 2250VDC  
isolation, no CM  
cap  
D   
No Suffix   
RoHS  
lead-solder-  
exemption  
compliant  
Through  
hole  
0.440”  
for  
xxx0x  
xxxKx  
N   
One-  
Eighth  
Brick  
Negative  
T   
Through-  
hole  
K 1500VDC  
isolation,  
(w/CM cap.)  
A   
0.188”  
20 120   
20 ADC 12V  
36-75 V  
Format  
P   
Positive  
G RoHS  
compliant for all  
six substances  
B   
0.145”  
0.520”  
for  
xxxBx  
B Baseplate  
option + „0‟  
above  
The example above describes P/N SQE48T20120-NDABG: 36-75V input, through-hole, 20A@12V output, negative ON/OFF logic, maximum  
height of 0.52”, 0.188” pin length, 2250VDC isolation, integral heat spreader (Baseplate) and RoHS compliant for all 6 substances. Consult  
factory for availability of other options.  
Notes:  
1. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written  
consent of the respective divisional president of Power-One, Inc.  
2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending  
on the date manufactured. Specifications are subject to change without notice.  
MCD10157 Rev. 1.5, 18-Apr-11  
www.power-one.com  
Page 13 of 13  

相关型号:

SQE48T20120-PDB0G

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ROHS COMPLIANT, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGA0

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGAB

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGAK

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGAKG

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ROHS COMPLIANT, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGB0G

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ROHS COMPLIANT, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGBB

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T20120-PGBBG

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, ROHS COMPLIANT, ONE-EIGHTH BRICK PACKAGE-5
BEL

SQE48T30012-NDA0

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-8
BEL

SQE48T30012-NDAL

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-8
BEL

SQE48T30012-NDALG

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

SQE48T30012-NDB0G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL