EXP [BULGIN]
EXP Series EXPlora - Hazardous Area; EXP系列探险 - 危险区域型号: | EXP |
厂家: | ELEKTRON COMPONENTS LTD. |
描述: | EXP Series EXPlora - Hazardous Area |
文件: | 总5页 (文件大小:3325K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
EXPLORA
EXP Series EXPlora - Hazardous Area
IP68
Terminals
Sealing Gasket
O Ring
Contact Insert
O Ring
O Ring
O Ring
Locking Ring
Main Body
Retaining
Nut
Panel Body
Contact Insert
Terminals
Cable Gland
Gland Cage
Gland Nut
ᔢ
ᔢ
ᔢ
ᔢ
ATEX approval for Zone 2 and Zone 22 applications
Independently tested
ᔢ
ᔢ
ᔢ
‘Scoop proof’ contacts
Field termination - screw terminations
Positive locating keyways - cannot be
mis-connected
ATEX Coding:
II 3 GD
ATEX Classification:
Ex nA IIC T6 Gc
Ex tc IIIC T85˚C Dc
ᔢ
Sealing caps available to maintain IP68 rating of
unmated connectors
ᔢ
ᔢ
ATEX Certificate No:
Baseefa09ATEX0232X
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
Compact design
IP68 rating tested at 1.054kg/sq cm (15lb/sq in)
10m depth for 2 weeks
Easy assembly - no special tools required
Single or 3 phase applications
Cost effective solution
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
Up to 18A, 600V ac/dc rating
2, 3, 4, 5, 7 and 10 pole
Cable acceptance from 7 to 22mm O/D
Leading earth contact for 3, 4, 5 & 7 pole versions
Trailing Neutral on 5 pole
Two cable connector versions for 15mm and 22mm
(maximum) cable diameters
Plug or socket connection in each body style
Water and dustproof to IP68 when mated
ᔢ
Separate strain relief on large cable version
www.bulgin.co.uk
1
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
FLEX CABLE CONNECTOR
ᔢ
ᔢ
Mates with in-line flex or
panel mounting versions
Positive, fast acting locking
ring - can be turned with a
gloved hand
ᔢ
ᔢ
Plug or socket versions
EXP-0 Series13-15mm cable
dia. acceptance as standard,
7-13mm with additional
gland pack
EXP-0911
ᔢ
ᔢ
EXP-A Series 20-22mm cable
dia. acceptance as standard,
14-20mm with additional
gland pack
Strain Relief Clamp
(EXP-A Series only)
EXP-A911
Flex Cable
Standard Cable
Large Cable
Description
Standard Cable
Large Cable
Description
EXP-0911/02/P
EXP-0911/03/P
EXP-0911/04/P
EXP-0911/05/P
EXP-0911/07/P
EXP-0911/10/P
EXP-A911/02/P
EXP-A911/03/P
EXP-A911/04/P
EXP-A911/05/P
EXP-A911/07/P
EXP-A911/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0911/02/S
EXP-0911/03/S
EXP-0911/04/S
EXP-0911/05/S
EXP-0911/07/S
EXP-0911/10/S
EXP-A911/02/S
EXP-A911/03/S
EXP-A911/04/S
EXP-A911/05/S
EXP-A911/07/S
EXP-A911/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
IN-LINE FLEX CABLE CONNECTOR
ᔢ
Mates with either EXP-0911
or EXP-A911 connectors
ᔢ
ᔢ
Plug or socket versions
EXP-0 Series13-15mm cable
dia. acceptance as standard,
7-13mm with additional
gland pack
ᔢ
ᔢ
EXP-A Series 20-22mm cable
dia. acceptance as standard,
14-20mm with additional
gland pack
Strain Relief Clamp
(EXP-A Series only)
EXP-0921
EXP-A921
In-Line Flex Cable
Standard Cable
Large Cable
Description
Standard Cable
Large Cable
Description
EXP-0921/02/P
EXP-0921/03/P
EXP-0921/04/P
EXP-0921/05/P
EXP-0921/07/P
EXP-0921/10/P
EXP-A921/02/P
EXP-A921/03/P
EXP-A921/04/P
EXP-A921/05/P
EXP-A921/07/P
EXP-A921/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0921/02/S
EXP-0921/03/S
EXP-0921/04/S
EXP-0921/05/S
EXP-0921/07/S
EXP-0921/10/S
EXP-A921/02/S
EXP-A921/03/S
EXP-A921/04/S
EXP-A921/05/S
EXP-A921/07/S
EXP-A921/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
www.bulgin.co.uk
2
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
PANEL MOUNTING CONNECTOR
ᔢ
Mates with EXP-0911 and
EXP-A911 connectors
ᔢ
ᔢ
ᔢ
ᔢ
Single hole fixing
Anti-rotation key
High grade sealing gasket
3-7mm panel thickness
EXP-0931
Panel Mounting
EXP-0931/02/P
EXP-0931/03/P
EXP-0931/04/P
EXP-0931/05/P
EXP-0931/07/P
EXP-0931/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0931/02/S
EXP-0931/03/S
EXP-0931/04/S
EXP-0931/05/S
EXP-0931/07/S
EXP-0931/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
FLANGE MOUNTING CONNECTOR
ᔢ
ᔢ
ᔢ
Mates with EXP-0911 and
EXP-A911 connectors
Supplied with high grade
sealing gasket
Supplied with sealing
grommets for panel fixing
screws (M6 thread
recommended)
EXP-0941
Flange Mounting
EXP-0941/02/P
EXP-0941/03/P
EXP-0941/04/P
EXP-0941/05/P
EXP-0941/07/P
EXP-0941/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0941/02/S
EXP-0941/03/S
EXP-0941/04/S
EXP-0941/05/S
EXP-0941/07/S
EXP-0941/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
www.bulgin.co.uk
3
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
Sealing Caps
ACCESSORIES
ᔢ
Heavy duty sealing caps to
maintain IP68 rating of
unmated connectors, with
stainless steel straps
EXP-0990
Heavy duty sealing cap for use with
EXP-0911/xx/x and EXP-A911/xx/x
EXP-0991
EXP-0992
Heavy duty sealing cap for use with
EXP-0921/xx/x and EXP-A921/xx/x
Heavy duty sealing cap for use with
EXP-0931 and EXP-0941
Gland Packs
EXP-0990, EXP-0991, EXP-0992
EXP-0980
Pack of 3 additional cable glands for
EXP-0911 and EXP-0921 to suit cable sizes;
11-13mm, 9-11 and 7-9mm dia.
EXP-A980
Pack of 3 additional cable glands for
EXP-A911 and EXP-A921 to suit cable sizes;
18-20mm, 16-18 and 14-16mm dia.
PART NO SYSTEM
EXP-09 x x / xx / x / x
Series Designation
09 = Standard Cable Accommodation (7-13mm)
A9 = Large Cable Accommodation (14-22mm)
Body Styles
1 = Flex, 2 = Flex In-line,
3 = Panel, 4 = Flange Panel
Contact Termination
1 = Screw Terminal
Number Contacts
02 = 2 pole, 03 = 3 pole, 04 = 4 pole,
05 = 5 pole, 07 = 7 pole, 10 = 10 pole
Contact Type
P = Plug, S = Socket
Cable Acceptance
EXP-0 version:
EXP-A version:
Blank = 13-15mm Yellow cable gland (standard)
Blank = 20-22mm Yellow cable gland (standard)
3 = 11-13mm
2 = 9-11mm
1 = 7-9mm
Black cable gland
White cable gland
Dark Grey cable gland
9 = 18-20mm
8 = 16-18mm
7 = 14-16mm
Black cable gland
White cable gland
Dark Grey cable gland
Example:
EXP-0911/07/P/3 = Flex cable connector with standard cable accommodation body, seven
pin contacts, with gland to suit 11-13mm cable.
www.bulgin.co.uk
4
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
SPECIFICATION
Electrical:
Mechanical:
No Poles:
2, 3, 4, 5
18A
7
10
10A
Sealing:
IP68, EN60529:2001 tested @
1.054kg/sq.cm. (15lb/sq.in.) 10m depth for
2 weeks
Current Rating:
16A
Voltage Rating:
600Vac/dc
430Vac/dc
250Vac/dc
Cable Acceptance:
EXP-0911 - EXP-0921 13 - 15mm O/D standard,
7-13mm with gland pack
EXP-A911 - EXP-A921 20 - 22mm O/D standard,
14 - 20mm with gland pack
Contact Resistance:
Insulation Resistance:
Dielectric strength:
AC Breakdown voltage:
Ambient Temperature Range:
Standards:
<10mΩ (initial)
6
>10 MΩ (@ 500V dc)
2
Contact Accommodation:
2.5 to 4mm (13 to10AWG) conductor,
2.2kV ac min
6kV
single or multi stranded
Termination:
Axial screw terminals
–20°C to +55°C
Cable Retention force:
22mm dia, 150N
15mm dia, 150N
7mm dia, 80N
ATEX Zone 2 and Zone 22
IEC60079-0:2007
IEC60079-15:2005
Gland Nut Torques:
EXP-0 range
ATEX Coding:
II 3 GD
13-15mm (Yellow - std.)
11-13mm (black)
9-11mm (white)
7-9mm (dark grey)
EXP-A range
3.16Nm (28 lb/in)
3.16Nm (28 lb/in)
3.16Nm (28 lb/in)
3.16Nm (28 lb/in)
ATEX Certificate No:
ATEX Classification:
Baseefa09ATEX0232X
Ex nA IIC T6 Gc
Ex tc IIIC T85˚C Dc
20-22mm (Yellow - std.)
18-20mm (black)
16-18mm (white)
14-16mm (dark grey)
3.16Nm (28 lb/in)
3.16Nm (28 lb/in)
3.16Nm (28 lb/in)
3.16Nm (28 lb/in)
Materials:
Body Mouldings:
Flammability Rating:
UV Resistance:
Contacts:
Polyester
Tightening Torques:
Panel mount nut
Flange & Bulkhead
fixing screws
UL94V-0
2.25 Nm
0.9 Nm
To EN50021:1999
Machined Solid Brass, Nickel plated
O Rings:
Nitrile
Panel Sealing Gasket:
Silicone Rubber
Compliant
Dimensions:
Overall dimensions of connectors when mated together
EXP-0911 + EXP-0921
EXP-A911 + EXP-A921
230 mm max.
270 mm max.
CONTACT LAYOUT
EXP-0911 + EXP-0931
EXP-A911 + EXP-A931
135 mm max. (to panel)
175 mm max. (to panel)
EXP-0911 + EXP-0941
EXP-A911 + EXP-A941
145 mm max. (to panel, mid point on flange)
174 mm max. (to panel, mid point on flange)
2 pole
5 pole
3 pole
7 pole
4 pole
10 pole
www.bulgin.co.uk
5
相关型号:
©2020 ICPDF网 联系我们和版权申明