CTD-3X8005AXXX [CARLOGAVAZZI]

Accessories AC Current Transformer;
CTD-3X8005AXXX
型号: CTD-3X8005AXXX
厂家: Carlo Gavazzi    Carlo Gavazzi
描述:

Accessories AC Current Transformer

文件: 总2页 (文件大小:555K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Accessories  
AC Current Transformer (max 51x15 mm bus-bar)  
Type CTD-3X  
Bus-bar type current transformer  
0.5 class, currents from 50 to 800 A  
Integrated DIN-rail mounting holder  
Removable panel fixing clips  
Up to 6 Bus-bar isolated fixing screws  
Double screw terminals (up to 8-wire connections)  
Sealable terminal block covers  
Product Description  
Ordering Key  
CTD-3X 800 5A XXX  
Cable/Bus-bar type current Rated primary currents from Model  
transformer with DIN-rail/ 50 A to 800 A.  
bus-bar and panel mounting  
facility.  
Primary current  
Secondary current  
Option  
Optional fixing kit:  
CTD-kit  
Type Selection  
Primary current  
Secondary current  
Option  
From 50 to 800A  
(Refer to Range Table)  
1A  
5A  
XXX: none  
XTX: tropicalization  
Input Specifications  
Operating frequency  
Max. system voltage  
Rated insulation level  
Insulation class  
Short-time current rating  
Ith  
Idyn  
45 to 65 Hz  
0.72 kV  
3 kV/1 min. @ 50 Hz  
E (max 75°C)  
Six plastic caps for  
cable/bus-bar fixing screws.  
Special features  
1 A secondary current,  
Tropicalization  
-25°C to +60°C (-13°F to  
140°F) (R.H. < 90% non  
condensing @ 40°C)  
-30°C to +70°C (-22°F to  
158°F) (R.H. < 90% non  
condensing @ 40°C)  
Working temperature  
Typical 100 In /1 s  
2.5 Ith  
The short-time thermal  
current Ith is anyway limited  
by the cable/bus-bar size  
120%  
5 (Class: 0.5, 1 and 3)  
Storage temperature  
Approvals  
Connection  
Cable cross section area  
CE, cUrus and CSA  
Extended current rating  
Security factor (FS)  
Screw type  
From 1.5 to 6 mm2  
Min/Max screws tightening  
torque relevant to terminal  
block screws:  
General Specifications  
From 1 to 2 Nm  
Standards  
Housing  
According to EN61869-2  
ABS, self-extinguishing:  
UL 94 V-0  
DIN-rail bus-bar  
and panel mounting  
Two terminal block screws.  
Two cable/bus-bar  
fixing screws.  
Two plastic caps for  
cable/bus-bar fixing screws.  
Two panel mounting  
fixing clips.  
Two sealable terminal block  
covers.  
Max screws tightening  
torque relevant to the  
cable/bus-bar fixing screws:  
0,3 Nm  
Mounting  
Protection degree  
Cable diameter  
Bus-bar size  
Horizontal  
Vertical  
IP00  
Standard accessories  
IP20 (with sealable terminal  
block covers + wire terminals)  
Max. 41 mm  
Max. 51x15; 40x20: 32x32 mm  
Max. 40x20 mm  
From 550 to 700 g  
Weight  
Optional accessories  
Extended fixing kit: CTD-kit  
Two panel mounting  
fixing clips.  
Six cable/bus-bar fixing  
screws.  
Output Specifications  
Rated secondary current  
5 A or 1 A  
Specifications are subject to change without notice CTD-3X DS ENG 140116  
1
CTD-3X  
Range Table  
Model CTD-3X from 50A to 200A  
Model CTD-3X from 250A to 800A  
Primary Current  
Burden (VA)  
CL 1  
Primary Current  
Burden (VA)  
A
CL 0.5  
CL 3  
1.75  
2
A
CL 0.5  
3.5  
7
CL 1  
6.5  
10  
CL 3  
10.5  
13  
50 (@60°C/140°F)  
60 (@60°C/140°F)  
70 (@60°C/140°F)  
75 (@60°C/140°F)  
80 (@60°C/140°F)  
100 (@60°C/140°F)  
120 (@60°C/140°F)  
125 (@60°C/140°F)  
150 (@60°C/140°F)  
160 (@60°C/140°F)  
200 (@60°C/140°F)  
250 (@60°C/140°F)  
300 (@60°C/140°F)  
400 (@60°C/140°F)  
500 (@50°C/122°F)  
600 (@50°C/122°F)  
700 (@40°C/104°F)  
750 (@40°C/104°F)  
800 (@40°C/104°F)  
2.5  
3
9
14  
17  
14  
18  
21  
3
17  
21  
24  
2
2.25  
2.5  
3
3.5  
4
22  
26  
29  
24  
28  
31  
4.5  
6
25  
29  
32  
2.25  
2.5  
3
3.5  
4.5  
6.5  
8.5  
Benefits  
1
2
3
4
5
6
7
8
9
10  
• Easy and quick mounting either on a panel or  
on a DIN-rail (see figure 1-2).  
• Protection of screw terminals using specific  
sealable covers to assure always the best  
safety (see figure 3).  
Dimensions (mm)  
30  
• Bridging of current transformer output without  
changing the connection of the secondary, so  
to avoid any output overvoltage during either  
the maintenance or the installation procedure  
(see figure 4).  
• Easy output and earth connection (see fig. 5).  
• Screw terminals compatible with any kind of  
wire terminals (see figure 6-7-8-9).  
• Multiple screws provided with isolation cap  
screws to grant a strong and reliable fixing of the  
current transformer to the bus-bar (see figure  
10).  
63  
38,5  
Wiring Diagram  
S1  
S2  
20,5  
32,5  
40,5  
42  
81,2  
51  
77  
L
P1  
P2  
N
2
Specifications are subject to change without notice CTD-3X DS ENG 140116  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY