EI1805PPOPS [CARLOGAVAZZI]

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30;
EI1805PPOPS
型号: EI1805PPOPS
厂家: Carlo Gavazzi    Carlo Gavazzi
描述:

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30

文件: 总3页 (文件大小:108K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Proximity Sensors Inductive  
Thermoplastic Polyester Housing  
Types EI, DC, M12, M18, M30  
• Euronorm thermoplastic polyester housing,  
cylindrical  
• Diameter: M12, M18, M30  
• Flush and non-flush types  
• Long and short body versions  
• Sensing distance: 2 to 15 mm  
• Power supply: 10 to 40 VDC  
• Output: Transistor NPN/PNP, Normally open or Normaly  
closed  
• Protection: Short-circuit, reverse polarity and overload  
• LED-indication for output ON  
• 2 m cable or M12 plug  
Product Description  
Proximity switch in M12, M18 euronorms EN 50 008 and Type  
and M30 polyester housings. EN 50 036.  
Made in accordance with  
Ordering Key  
EI 1808 PPCPL-1  
Housing diameter (mm)  
Rated operating dist. (mm)  
Output type  
Housing material  
Body style  
Plug  
Type Selection DC Types, Cable and M12 Plug  
Housing  
diameter  
Body  
style  
Connection  
Rated  
operating  
dist. (Sn)  
Ordering no.  
Transistor NPN  
Normaly open  
Ordering no.  
Transistor PNP  
Normaly open  
Ordering no.  
Transistor PNP  
Normaly closed  
M12  
M12  
M12  
Long  
Short  
Long  
Cable  
Cable  
Cable  
2 mm 1)  
4 mm 2)  
4 mm 2)  
EI 1202 NPOPL  
EI 1204 NPOPL  
EI 1202 PPOPL  
EI 1204 PPOPS  
EI 1204 PPOPL  
M18  
M18  
M18  
M18  
M18  
M18  
Short  
Long  
Short  
Short  
Long  
Long  
Cable  
Cable  
Cable  
Plug  
Cable  
Plug  
5 mm 1)  
5 mm 1)  
8 mm2)  
8 mm2)  
8 mm2)  
8 mm2)  
EI 1805 PPOPS  
EI 1805 PPOPL  
EI 1808 PPOPS  
EI 1808 PPOPS-1  
EI 1808 PPOPL  
EI 1805 NPOPL  
EI 1808 NPOPS  
EI 1808 NPOPL  
EI 1808 PPCPL  
EI 1808 PPOPL-1 EI 1808 PPCPL-1  
M30  
M30  
M30  
Long  
Short  
Long  
Cable  
Cable  
Cable  
10 mm 1)  
15 mm 2)  
15 mm 2)  
EI 3010 NPOPL  
EI 3015 NPOPS  
EI 3010 PPOPL  
EI 3010 PPCPL  
EI 3015 PPOPL  
1) For flush mounting in metal  
2) For non-flush mounting in metal  
Specifications  
Rated operational volt. (Ue)  
12 to 36 VDC  
10 to 40 VDC (ripple incl.)  
Frequency of operating cycles (f)  
(UB)  
EI 1202 800 Hz  
EI 1204 500 Hz  
EI 1805 500 Hz  
EI 1808 400 Hz  
EI 3010 300 Hz  
EI 3015 100 Hz  
Ripple  
10%  
Rated operational current (Ie)  
Continuous  
200 mA  
Output ON: < 6.5 mA  
Output OFF: < 2.7 mA  
No-load supply current (Io)  
Indication for output ON  
Assured operating dist. (Sa)  
Repeat accuracy (R)  
Hysteresis (H) (Differential travel) 1 to 15% of sensing distance  
Effective operating dist. (Sr)  
Usable operating dist. (S)  
LED, yellow  
Voltage drop (Ud)  
Protection  
2 VDC at max. load  
Reverse polarity, short-circuit,  
transients  
0 Sa 0.81 Sn  
5%  
Transient voltage  
Power ON delay  
700 V/0.5 J  
< 10 ms  
0.9 x Sn Sr 1.1 x Sn  
0.9 x Sr Su 1.1 x Sr  
Specifications are subject to change without notice (10.01.14)  
1
EI, DC, M12, M18, M30  
Specifications (cont.)  
Ambient temperature  
Operating  
Storage  
Weight (cable excluded)  
-25° to +70°C (-13° to +158°F)  
-30° to +80°C (-22° to +176°F)  
EI12 10 g  
EI 1805 18 g  
EI 1808 20 g  
EI 3010 50 g  
EI 3015 70 g  
Degree of protection  
Housing material  
Body  
Back  
IP 67 (Nema 1, 3, 4, 6, 13)  
Grey thermoplastic polyester  
Black polyester  
Tightening torque  
EI 12 1.8 Nm  
EI 18 2.6 Nm  
EI 30 7.5 Nm  
Connection  
Cable  
2 m, 3 x 0.3 mm2, grey PVC,  
oil proof  
M 12 x 1  
Approvals  
CE-marking  
EMC  
UL, CSA  
Yes  
Plug  
Cables for plug (-1)  
CONH1A serie  
Approved acc. to EN 50 080,  
EN 50 081  
Dimensions  
Type  
A
B (Ø mm) C (mm)  
D (mm)  
11  
E (mm)  
F (mm)  
SW (mm)  
EI 1202 XPXPL  
EI 1204 XPXPS  
EI 1204 XPXPL  
M 12 x 1 x 50  
M 12 x 1 x 30  
M 12 x 1 x 50  
10.7  
10.7  
10.7  
50  
34  
54  
5.0  
5.0  
5.0  
8
8
8
17  
17  
17  
11  
11  
EI 1805 XPXPS  
EI 1805 XPXPL  
EI 1808 XPXPS  
EI 1808 XPXPL  
EI 1808 XPXPL-1  
M 18 x 1 x 30  
M 18 x 1 x 50  
M 18 x 1 x 30  
M 18 x 1 x 50  
M 18 x 1 x 50  
16.7  
16.7  
16.7  
16.7  
16.7  
30  
50  
38  
58  
58  
11.6  
11.6  
11.6  
11.6  
13.1  
15.4  
15.4  
15.4  
15.4  
11.9  
8
8
8
8
8
24  
24  
24  
24  
24  
EI 3010 XPXPL  
EI 3015 XPXPS  
EI 3015 XPXPL  
M 30 x 1.5 x 50  
M 30 x 1.5 x 30  
M 30 x 1.5 x 50  
28  
28  
28  
50  
42  
62  
13.6  
13.6  
13.6  
15.4  
15.4  
15.4  
10  
10  
10  
36  
36  
36  
C
D
E
C
D
E
M 12 x 1  
F
F
SW  
SW  
A
LED  
LED  
A
Cable  
Plug  
Wiring Diagrams  
+
+
-
1 BN  
+
+
-
1 BN  
1 BN  
1 BN  
4 BK  
BK  
2
BK  
2
4 BK  
3 BU  
3 BU  
3 BU  
3 BU  
-
-
NPN - Normally open  
NPN - Normally closed  
PNP - Normally open  
PNP - Normally closed  
2
Specifications are subject to change without notice (10.01.14)  
EI, DC, M12, M18, M30  
Installation Hints  
To avoid interference from inductive voltage/  
current peaks, separate the prox. switch  
power cables from any other power cables,  
e.g. motor, contactor or solenoid cables  
Relief of cable strain  
Protection of the sensing face  
Switch mounted on mobile carrier  
Incorrect  
Correct  
The cable should not be pulled  
A proximity switch should not serve as  
mechanical stop  
Any repetitive flexing of the  
cable should be avoided  
Power Supplies  
Power supplies VAC:  
Power supplies VDC:  
> SS 110.  
> SS 130/140.  
Power supplies with amplifier relays: > SV 190.  
Specifications are subject to change without notice (10.01.14)  
3

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY