UA30CAD35PGTI [CARLOGAVAZZI]
Ultrasonic Diffuse, Analogue and Digital Output;型号: | UA30CAD35PGTI |
厂家: | Carlo Gavazzi |
描述: | Ultrasonic Diffuse, Analogue and Digital Output |
文件: | 总4页 (文件大小:344K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Ultrasonic
Diffuse, Analogue and Digital Output
Types UA30CAD......TI
• Cylindrical M30 PBT housing
• Sensing distance: 250-3500 mm
• Power supply: 12 (15) to 30 VDC
• Outputs: 0-10 VDC or 4-20 mA and one switching
output NPN or PNP.
• Linearity error 0.5%
• Repeatability 0.2%
• Beam angle. ±±6
• Protection: Short-circuit, reverse polarity and
overvoltage
• Protection degree IP ±7, Nema 4X
• 2 m cable or M12 plug
Product Description
Ordering Key
UA30CAD35NGM1TI
A family of diffuse ultrasonic
sensors with sensing range
from 250-3500 mm with a
resolution as low as 2.0 mm.
The sensor contains both an
analogue and a digital output.
The output is either 0-10V or
4-20 mA and the digital output
NPN or PNP, NO or NC which
forms a windows detection.
The sensor is the ideal choice Ultrasonic sensor
for distance measurement, Housing style
level measurement, diameter Housing size
measurement or loop control. Housing material
Due to use of microproces- Housing length
sor control the digital filtering Detection principle
makes the sensor immune to Sensing distance
most electromagnetic inter- Output type
ferences.
Output configuration
Connection
Teach-in
Type Selection
Housing
diameter
Connec-
tion
Rated operating
dist. (Sn)
Analog
Output
Digital output
NPN/PNP
Ordering no.
M30
M30
M30
M30
M30
M30
M30
M30
Plug M12
Cable
Plug M12
Cable
Plug M12
Cable
Plug M12
Cable
250-3500 mm
250-3500 mm
250-3500 mm
250-3500 mm
250-3500 mm
250-3500 mm
250-3500 mm
250-3500 mm
4-20 mA
4-20 mA
0-10 V
NPN
NPN
NPN
NPN
PNP
PNP
PNP
PNP
UA 30 CAD 35 NG M1 TI
UA 30 CAD 35 NG TI
UA 30 CAD 35 NK M1 TI
UA 30 CAD 35 NK TI
UA 30 CAD 35 PG M1 TI
UA 30 CAD 35 PG TI
UA 30 CAD 35 PK M1 TI
UA 30 CAD 35 PK TI
0-10 V
4-20 mA
4-20 mA
0-10 V
0-10 V
Specifications
Rated operating distance (Sn) Reference target: 1 mm
metal rolled finish, size
Rated operational voltage (UB)
NG or PG versions
NK or PK versions
12 to 30 VDC
15 to 30 VDC
(ripple included)
200 x 200 mm.
250 - 3500 mm
Blind zone
≤ 250 mm
0.2%
Ripple (Urpp
No-load supply current (Io)
Output current continuous
digital output (Ie)
Max. load capacity 100 nF
)
≤ 5%
Repeatability
Linearity error
Beam angle
Sensitivity
Push-button
50 mA @ UB max
0.5%
±±6
100 mA
Output current short-time
digital output (I)
Max. load capacity 100 nF
P1 (longest setpoint)
P2 (shortest setpoint)
2 mm
100 mA
0.5 mA
10 μA
Resolution
Minimum operational current
digital output (Im)
OFF-state current digital
output (Ir)
Temperature drift
Temperature compensation Yes
Hysteresis (H)
0.1%/6C @ -206 to +706 C
Min. 0.5%
Specifications are subject to change without notice (12.05.2014)
1
UA30CAD..
Specifications (cont.)
Voltage drop digital output (Ud) ≤ 2.2 VDC @ 100 mA
Environment
Installation category
lll (IEC ±0±±4/±0±±4A;
±0947-1)
3 (IEC ±0±±4/±0±±4A;
±0947-1)
IP±7 (IEC ±0529; ±0947-1)
Nema 4X
Protection
Digital output
Short-circuit, overvoltage
pulses and reverse polarity
Overvoltage pulses and
reverse polarity
Pollution degree
Supply
Degree of protection
Analogue output
Overvoltage pulses
Ambient temperature
Operating
Storage
Analog output
NG.. or PG.. types
NK.. or PK.. types
-20° to +70°C (-4° to +158°F)
-35° to +70°C (-31° to +158°F)
4 to 20 mA
0 to 10 VDC
Vibration
10 to 55 Hz, 1.0 mm/±G.
(IEC/EN ±00±8-2-±)
Load
4 to 20 mA
0 to 10 VDC
max. 500 Ω
min. 3 kΩ
Shock
30 g / 11 mS, 3 directions
(IEC/EN ±00±8-2-27)
Carrier frequency
Operating frequency digital
output (f)
Response time OFF-ON
digital output (tON
Response time ON-OFF
digital output (tOFF
Response time analog output ≤ 500 mS
112 kHz
Rated insulation voltage
Housing
Material body
< 500 VAC (rms)
≤ 2 Hz
PBT
Material front
Epoxy-glass resin
Grilamid
Grilamid
TPE
TPE
TPE
)
≤ 250 mS
≤ 250 mS
Material back, plug
Material back, cable
Material push-button
Sealing around push-button
Material sealing front
)
Power ON delay
≤ 500 mS
Connection
Output function, open
collector
Cable
PVC, grey, 2 m,
4 x 0.34 mm2, Ø = 4.7 mm
M12, 4-pin (CON. 14-series)
By sensor type
NPN or PNP
Plug
Output switching function
One open collector transis-
tor and one analogue
Tightening torque
≤ 1.5 Nm
output to be configured as:
- Windows function with
N.O or N.C. output.
- Analogue output with
positive or negative slope.
Weight
Cable version
Plug version
1±0 g
90 g
CE-marking
Approvals
Yes
cULus (UL508)
Indication
Output ON
Echo received
Yellow LED
Green LED
Wiring Diagram
Detection Range
X
Target
Y
Distance (feet)
4.9 6.6
Sensor
BN1
WH2
BN1
WH2
0
1.6
3.3
8.2
9.8 11.5
400
300
200
100
0
15.7
11.8
7.9
BK4
BK4
I
PNP:
U
BU3
BU3
3.9
Voltage
Current
0
BN1
BN1
-100
-200
-300
-400
-3.9
-7.9
-11.8
-15.7
I
BK4
BK4
U
NPN:
WH2
WH2
BU3
BU3
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Distance (m)
2
Specifications are subject to change without notice (12.05.2014)
UA30CAD..
Dimensions
Plug
Cable
89.8
69.6
89.8
69.6
Teach
Teach
Teach
Teach
Yellow
Green
Yellow
Green
10
3
10
3
10
Programming setup
General set up of sensing point P1 (longest distance) and Shortest distance (P2) independent on the sensor type or
function.
1) Mount the sensor in the selected application
2) Place a target in front of the sensor at the maximum required distance (P1), then press shortly on the teach-button,
the Yellow LED switch Off and then On again after maximum 2 seconds. The distance (P1) is now saved in the
sensor, and the target can be moved. I)
3) Place the target at the minimum distance requested (P2), then press shortly on the teach-button, the yellow LED
turn Off then flash 5 times . The distance (P2) is now saved in the sensor and the target can be moved. II)
I) P1 can be set to a maximum exceeding the family specification for the sensor by removing the target in front of
the sensor, push and hold the teach-button more than one second and the sensing distance is set at a unique
distance for this sensor only. Do not use this function for an analogue output.
II) The second switch point can be set to minimum by setting the target within the blind zone close to the sensor
head or by covering the sensor head with your hand while teaching P2.
Sensors with 1 digital output and one analogue output UA..CAD..PG/PK/NG or NK types
1) The factory setting is Normally Open N.O. for the digital output and positive slope for the analogue output.
Digital output
distance
2) To reverse the slope to negative and reverse the N.O. output to Normally Closed N.C. Push the teach-button for 8
second until the yellow LED flash fast release the teach button and the LED will flash 5 times to acknowledge the
change in function.
Digital output
3) To switch back to positive slope or N.O. output, repeat step 2.
Specifications are subject to change without notice (12.05.2014)
3
Installation Hints
To avoid interference from inductive voltage/ Relief of cable strain
current peaks, separate the prox. switch
Protection of the sensing face
Switch mounted on mobile carrier
power cables from any other power cables,
e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
Any repetitive flexing of the
cable should be avoided
A proximity switch should not serve as
mechanical stop
Delivery Contents
Accessories
• Connector type CONM14NF.. series
• Ultrasonic sensor: UA30CAD....
• Installation instruction
• Mounting:
2 x M30 Nuts
2 x rubber washers
• Packaging: Carton box 35 x 107 x 173 mm
4
Specifications are subject to change without notice (12.05.2014)
相关型号:
©2020 ICPDF网 联系我们和版权申明