SIL865970 [CELDUC]

AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.; AC半导体接触器间距22,5mm紧凑的尺寸和DIN导轨安装。
SIL865970
型号: SIL865970
厂家: celduc-relais    celduc-relais
描述:

AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.
AC半导体接触器间距22,5mm紧凑的尺寸和DIN导轨安装。

半导体
文件: 总4页 (文件大小:267K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
S/CLP/SIL865970/B/21/04/2004  
®
celpac  
page 1 / 4GB  
AC Semiconductor Contactor  
pitch 22,5mm  
SIL865970  
compact size and DIN rail mounting.  
Output : 24-510VAC 32A(*)  
Input : 150-240VAC/DC  
Ready to use Single-Phase Relay: " Install it & Forget it!"  
Zero cross model : 24-510VAC 50A  
back to back thyristors on output -  
TMS2 technology - I2t value > 1500A2s  
Large control range : 150-240VAC/DC  
Green LED visualization on the input.  
Very high immunity : Voltage protection on output  
and input- 4kV according IEC61000-4-4 & 5  
IP20 housing  
Low leakage current (<1mA) and low zero cross  
voltage.  
Mounting and dismounting on DIN rail without any  
tool or directly mountable on panel.  
Designed in conformity with EN60947-4-3  
(IEC947-4-3) and EN60950  
-UL-cUL  
(*) see conditions (thermal curve page 3)  
22A  
400VAC 50hz  
Dimensions :  
Protection  
L1  
SSR  
T1  
Typical  
application:  
A2 A1  
9kW resistor  
Commande  
(AC-51 load)  
on 400 VAC  
Load  
Proud to serve you  
celduc  
All technical caracteristics are subject to change without previous notice.  
Caractéristiques sujettes à modifications sans préavis.  
r e l a i s  
S/CLP/SIL865970/B/21/04/2004  
®
celpac  
page 2 / 4GB  
Control characteristics (at 25°C)  
Input : Ic = f( Uc)  
DC  
8
6
4
2
0
Paramètre / Parameter  
Control voltage : AC control  
Control voltage : DC control  
Control current (@ Uc )  
Release voltage  
Symbol Min  
Nom Max Unit  
Uc  
Uc  
150  
110  
3
230  
240  
240  
7
VAC  
VDC  
mA  
V
Ic  
Uc off  
15  
Input LED  
green  
0
50  
100  
150  
200  
250  
Input immunity : EN61000-4-4  
Input immunity : EN61000-4-5  
2kV  
2KV  
U c (V)  
Output characteristics (at 20°C)  
Parameter  
Conditions  
Symbol  
Ue  
Uemin-max  
Up  
Typ.  
400  
24-510  
1200  
Unit  
Load voltage  
Operating range  
Peak voltage  
V rms  
V rms  
V
Clamping voltage  
Zero cross level  
Latching voltage  
Uclamp  
Usync  
Ua  
820 (@1mA)  
V
V
V
20  
8
Ie nom  
AC-51 nominal current : permanent  
AC-53 nominal current  
Non repetitive overload current  
On state voltage drop (typical value)  
Dynamic resistance (typical value)  
( see Fig. 2 page 3)  
Ie AC-51  
Ie AC-53  
Itsm  
32  
12  
550  
0,9  
8
A rms  
A rms  
A
V
mW  
tp=10ms (Fig. 3)  
@ 25°C  
Vt  
rt  
Output Power dissipation (typical value)  
Pd  
0,81xIe+0,08xIe2  
W
Thermal resistance between junction to air  
Off state leakage current  
Minimum load current  
Turn on time  
Turn off time  
Operating frequency range  
Off state dv/dt  
Rthj/a  
Ilk  
Iemin  
ton max  
toff max  
f
dv/dt  
di/dt  
I2t  
3,3 (2,5)  
K/W  
mA  
mA  
ms  
ms  
Hz  
V/µs  
A/µs  
A2s  
@Ue, 50Hz  
<1  
5
30  
30  
0,1-440  
500  
50  
1500  
Uc nom DC ,f=50Hz  
Uc nom DC ,f=50Hz  
Maximum di/dt non repetitive  
I2t (<10ms)  
Conducted immunity level  
Conducted immunity level  
Short circuit protection  
IEC 1000-4-4 (burst)  
IEC 1000-4-5(schocks)  
FERRAZ  
4kV criterion A  
4kV criterion A  
gRC 25A/32A/50A/63A 14x51  
General characteristics (at 20°C)  
Input to output insulation  
Output to case insulation  
Insulation resistance  
Rated impulse voltage  
Ui  
Ui  
Ri  
Uimp  
4000  
4000  
100 (@500VDC)  
VRMS  
VRMS  
MW  
V
4000  
Protection level / CEI529  
Pollution degree  
-
-
IP20  
2
Vibration resistance 10 -55 Hz according to CEI68 :  
Shocks resistance according to CEI68 ( on DIN rail / with screws)  
Ambient temperature (with no icing or condensation)  
Storage temperature (with no icing or condensation)  
Ambient humidity  
Weight  
double amplitude  
1,5  
30/50  
-30 /+80  
-30/+100  
40 to 85  
mm  
g
°C  
°C  
%
-
-
HR  
260  
g
Conformity  
Conformity  
EN60947-4-3 (IEC947-4-3)  
EN60950 UL/cUL pending  
celduc  
www.celduc.com  
r
e
l
a
i
s
Rue Ampère B.P. 4  
42290 SORBIERS - FRANCE  
E-Mail : celduc-relais@celduc.com  
Fax +33 (0) 4 77 53 85 51  
Service Commercial France Tél. : +33 (0) 4 77 53 90 20  
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19  
S/CLP/SIL865970/B/21/04/2004  
®
celpac  
page 3 / 4/GB  
Thermal specifications .  
Current according ambient temperature :  
45  
40  
35  
30  
25  
20  
15  
10  
5
Ø
The curve "1" gives the limits of the product.  
The temperature reached are acceptable for the com-  
ponents. These values are in compliance with most of  
SSRs manufacturers.  
In a cabinet with a minimum of ventilation or a non  
permanent current, these values are correct.  
1
Ø
The curve "2" gives the limits of the product  
according to EN60947-4-3 with a maximum rise  
temperature of 50°C (@40°C) for a permanent  
working and in air calm ( test during 8 hours).  
2
Ø
For a non permanent current, you can calcule  
the average power = Pd x duty cycle and check the  
rise temperature : Tj = Pd x Rthj/a (Pd and Rthj/a are  
given page 2)). The junction temperature must not  
exceed 125°C at the maximum ambient temperature.  
The maximum current is limited to the size of the  
thyristors = 50A.  
0
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85  
Tambient(°C)  
Ø
The thermal constant (Cth) of the product is 7  
minutes. That means the rise temperature is only 63%  
of the stabilized temperature after a running time of  
7 minutes.  
fig 2  
Surge current : Itsm (Apeak) = f(t) for 50A models with Itsm =550A  
Fig.3  
Overload current .  
1 - No repetitive Itsm is given without voltage  
reapplied . This curve is used for the  
determination of the protection.  
600  
1
400  
2 - Repetitive Itsm is given for inrush current  
with initial Tj = 70°C. In normal working , this  
curve musn't be exceed. Be carefull, the  
repetition of the surge current decrease the  
lifetime SSR's .  
No repetive surge current without voltage reapplied.  
2
200  
0
Repetive surge current with voltage reapplied.  
fig 3  
0,01  
0,1  
1
10  
t (s)  
Mounting and dismounting on DIN rail without any tool.  
Panel Mounting  
M5  
M4  
Mount ing  
88±2mm  
DIN rail connected to  
protection wire (ground) .  
Dismount ing  
12,7mm  
Ø
Warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in  
conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable isolation in the  
event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...).  
celduc  
www.celduc.com  
r
e
l
a
i
s
Rue Ampère B.P. 4  
42290 SORBIERS - FRANCE  
E-Mail : celduc-relais@celduc.com  
Fax +33 (0) 4 77 53 85 51  
Service Commercial France Tél. : +33 (0) 4 77 53 90 20  
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19  
S/CLP/SIL865970/B/21/04/2004  
®
celpac  
page 4 / 4GB  
wires  
torques  
screwdriver  
Connections .  
L
L
(mm2)  
Ø
For the output terminals, the wire cross sections must  
screwdriver  
be adapted to the load current and to the overcurrent protection  
device characteristics. The relay rated voltage must be adapted  
to the mains rated voltage.  
control  
1 x(0,75-->2,5)  
L = 6mm  
0,4N.m  
(0,6N.m max)  
3,5x0,5mm  
Ø
celpac use screw clamp connections.  
Power  
1x(1,5-->16) 1 x(1,5-->10)  
L = 10mm  
1,2N.m  
(1,8N.m max)  
Pozidriv2/  
0,8x5,5 (1x6)  
Mounting  
Ø
Warning : only in vertical position. The user should protect heat sensitive materials as  
well as persons against any contacts with the heatsink. For non vertical mounting , the load  
current must be 50% lower than the rated one . For a good cooling, the SSR needs an air  
convection. Less convection air produces an abnormal heating. Keep a distance between  
the upper SSR and the lower SSR. In case of no space between two SSR ( zero space  
between two SSRs) , please reduce the load current. For further details refer to below :  
Ø Derating current with no space between SSRs  
AC-51 nominal currents are given with a space of 22,5mm between each SSR, for a  
permanent current during a minimum time of 8 hours in air calm according to IEC60947-4-3.  
In case of non permanent currents or in case of SSRs are mounted with no space, you must  
check the heatsink temperature never exceed 90°C. When the SSRs are mounted side to  
side ( no space between each relay) a derating current of 25% must be take into account.  
A forced cooling ( fan inside the cabinet) improves significantly the thermal performances.  
vert ical  
posit ion  
8 0 mm  
Typical application : LOADS  
SIL product is designed mainly for AC-51 résistive load. AC-53 motor current are  
also given . For other loads, check the inrush current at turn ON and possible overvoltages  
at turn OFF or consult us :  
* AC-55b : Incandescent lamps : Inrush current is generally 10 times In during few 10ms.  
So limit the nominal current at about 15A.  
* AC-55a : Electric discharge lamp : These loads often have overcurrent at turn ON and  
overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains.  
* AC-56a : Transformers loads : Very high inrush current up to 100 times In . We advise to  
use random SSR.  
1 ~  
* AC-56b : Capacitors loads : Very high current at turn ON and overvolatge at turn OFF,  
please consult us with 1600V peak SSR with high inrush current.  
Fuse  
Fusible  
Protection :  
2
2
To protect the SSR against a short-circuit of the load , use a fuse with a I t value = 1/2 I t  
value specified page 2. A test has been made with FERRAZ fuse ( see page 2).  
L1  
T1  
It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application  
2
2
note ( SSR protection) and use a SSR with high I t value (5000A s minimum).  
EMC :  
Ø
Immunity :  
We give in our data-sheets, the immunity level of our SSRs according to the main  
standards for this type of products : EN61000-4-4 &5. You can see the high immunity level  
in comparison with the products on the market.  
A1  
A2  
Ø
Emission:  
cont rol  
SSRs are complex devices which must be interconnected with other equipment  
Load  
Charge  
(loads, cables,etc.) to form a system. Because the other equipment or the interconnections  
may not be under the control of celduc it shall be the responsibility of the system integrator  
to ensure that systems containing SSRs comply with the requirements of any rules and  
regulations applicable at the system level. The very low zero cross voltage (<20V) improves  
the conducted emission level in comparison with most of SSR on the market with zero cross  
voltage higher than 50V. Consult celduc laboratory which can make some tests in your  
application.  
N
celduc  
www.celduc.com  
r
e
l
a
i
s
Rue Ampère B.P. 4  
42290 SORBIERS - FRANCE  
E-Mail : celduc-relais@celduc.com  
Fax +33 (0) 4 77 53 85 51  
Service Commercial France Tél. : +33 (0) 4 77 53 90 20  
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19  

相关型号:

SIL867170

AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.
CELDUC

SIL87374X

Transceiver, 1-Func, HERMETIC SEALED MODULE
INFINEON

SIL9-81.8KOHM

RESISTOR, NETWORK, FILM, BUSSED, 0.8W, THROUGH HOLE MOUNT, SIP
VISHAY

SIL9-8560KOHM

RESISTOR, NETWORK, FILM, BUSSED, 0.8W, THROUGH HOLE MOUNT, SIP
VISHAY

SIL9-8560OHM

RESISTOR, NETWORK, FILM, BUSSED, 0.8W, THROUGH HOLE MOUNT, SIP
VISHAY

SIL9-856KOHM

RESISTOR, NETWORK, FILM, BUSSED, 0.8W, THROUGH HOLE MOUNT, SIP
VISHAY

SIL9-856OHM

RESISTOR, NETWORK, FILM, BUSSED, 0.8W, THROUGH HOLE MOUNT, SIP
VISHAY

SIL9-868OHM

RESISTOR, NETWORK, FILM, BUSSED, 0.8W, THROUGH HOLE MOUNT, SIP
VISHAY

SIL9022

HDMI TRANSMIT
SII

SILA180

180W L-Bracket Power Supply for Industrial Equipment
Vitec

SILA180-S05

180W L-Bracket Power Supply for Industrial Equipment
Vitec

SILA180-S08

180W L-Bracket Power Supply for Industrial Equipment
Vitec