16200-2 [COOPER]
Splicer blocks;型号: | 16200-2 |
厂家: | COOPER BUSSMANN, INC. |
描述: | Splicer blocks |
文件: | 总4页 (文件大小:1335K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical Data 10534
Effective June 2016
Splicer blocks
Catalog number example:
16204-3 is a 3-pole 16204
Where:
•ꢀ
The prefix “16204” defines the block’s lineside
and loadside characteristics (i.e., conductor port
per pole that accepts 2/0 - #14 Cu, or 2/0 - #12
Al conductors).
•ꢀ
The suffix “3” in this example defines this as a
three-pole block.
•ꢀ
See the catalog number tables for details on the
available lineside/loadside characteristics.
How to order:
From the catalog number tables, select the catalog
number that defines the desired lineside/loadside
port and conductor characteristics.
Add to the catalog number the suffix that defines
the desired pole configuration. Note, you must
select from the available number of poles for
each catalog number. These appear in the second
column of the catalog number tables.
Catalog symbols:
•ꢀ
160__-(poles)
Specifications:
•ꢀ
162__-(poles)
Ratings
•ꢀ
163__-(poles)
•ꢀ
•ꢀ
Volts: 600 V
165__-(poles)
•ꢀ
Amps: 115 to 760 A
Description:
•ꢀ
SCCR: up to 200 kA* (see table for SCCR by
catalog number)
Bussmann® series splicer blocks allow for
*
Maximum SCCR contingent upon the application of an
upstream current-limiting overcurrent protective device.
See table for fusing requirements.
increasing or decreasing wire size within a circuit
to accommodate different connections from the
power source to the branch load.
Flammability rating
Splicer blocks are available for wire sizes up to 500
kcmil and amp ratings up to 760 A.
•ꢀ
UL 94 V0
They are UL® Recognized to UL 1059 and rated for
use in UL 508A industrial control panels.
Agency information
•ꢀ
UL 1059 Recognized, Guide XCFR2, File E62622
These blocks are factory configured from 1- to
4-poles (catalog number dependent) with optional
covers available to enhance safety (order covers
separately).
CSA® Certified, Class 6228-01, File 15364
•ꢀ
Conductors†
•ꢀ
Stranded 75°C copper and aluminum
•ꢀ
Higher temperature rated conductors permitted
with appropriate derating
† As specified in the catalog number table.
Optional covers
•ꢀ
See table for catalog numbers specific to each
block
Technical Data 10534
Splicer blocks
Effective June 2016
Catalog numbers:
Lineside
Loadside
Current
No. of rating
poles (A)
Wires Torque
Wires Torque
Line/load port
configuration
Wire size
per
N•m
Ports/ Wire size
per
N•m
Ports/ SCCR Catalog
(Str/ferrule unless noted)*
port
(Lb-in)
Pole
(Str/ferrule unless noted)*
port
(Lb-in)
pole
(kA)
number
#2 - #3 Cu/Al (Str)
#4 - #6 Cu/Al (Str)
#8 Cu/Al (Str)
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
2
5.6 (50)
5.1 (45)
4.5 (40)
4.0 (35)
5.6 (50)
5.1 (45)
4.5 (40)
4.0 (35)
#2 - #3 Cu/Al (Str)
#4 - #6 Cu/Al (Str)
#8 Cu/Al (Str)
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
2
5.6 (50)
5.1 (45)
4.5 (40)
4.0 (35)
5.6 (50)
5.1 (45)
4.5 (40)
4.0 (35)
1, 2, 3 115
1, 2, 3 150
1
1
10
16200-_**
#10 - #14 Cu (Str)
1/0 - #3 Cu (Str)
#4 - #6 Cu (Str)
#8 Cu (Str)
#10 - #14 Cu (Str)
1/0 - #3 Cu (Str)
#4 - #6 Cu (Str)
#8 Cu (Str)
1
1
1
1
10
10
16201-_
#10 - #14 Cu (Str)
2/0 - #1 Cu/Al (Str)
#2 - #8 Cu/Al
#10 - #14 Cu (Str)
2/0 - #1 Cu/Al (Str)
#2 - #8 Cu/Al
12.4 (110)
4.0 (35)
12.4 (110)
4.0 (35)
#10 - #12 Al (Str)
#10 - #14 Cu
#10 - #12 Al (Str)
#10 - #14 Cu
2, 3, 4 175
16000-_**
#4 - #8 Cu/Al
#4 - #8 Cu/Al
13.6 (120)
12.4 (110)
4.0 (35)
13.6 (120)
12.4 (110)
4.0 (35)
#10 - #14 Cu
#10 - #14 Cu
2/0 - #1 Cu/Al (Str)
#2 - #8 Cu/Al
2/0 - #1 Cu/Al (Str)
#2 - #8 Cu/Al
#10 - #12 Al (Str)
#10 - #14 Cu
#10 - #12 Al (Str)
#10 - #14 Cu
1, 2, 3 175
1
1
200†
16204-_
#4 - #8 Cu/Al
#4 - #8 Cu/Al
13.6 (120)
13.6 (120)
#10 - #14 Cu
#10 - #14 Cu
2, 3, 4 255
1, 2, ,3 255
250kcmil - #6 Cu
250kcmil - #6 Cu
1
1
42.4 (375)
42.4 (375)
1
1
250kcmil - #6 Cu
250kcmil - #6 Cu
1
1
42.4 (375)
42.4 (375)
1
1
10
10
16003-_**
16301-_
350kcmil - 2/0 Cu/Al (Str)
1/0 Cu/Al (Str)
1
350kcmil - 2/0 Cu/Al (Str)
1/0 Cu/Al (Str)
1
1-2
1-2
2, 3, 4 310
31.1 (275)††
1
31.1 (275)††
1
10
16005-_**
#1 - #6 Cu/Al
1-2
#1 - #6 Cu/Al
1-2
350kcmil - 2/0 Cu/Al (Str)
1/0 Cu/Al (Str)
1
350kcmil - 2/0 Cu/Al (Str)
1/0 Cu/Al (Str)
1
1-2
1-2
1, 2, ,3 310
1, 2, ,3 380
31.1 (275)††
56.5 (500)
1
1
31.1 (275)††
56.5 (500)
1
1
10
10
16303-_
16306-_
#1 - #6 Cu/Al
1-2
#1 - #6 Cu/Al
1-2
500kcmil - 4/0 Cu/Al (Str)
3/0 - 1/0 Cu/Al (Str)
1
500kcmil - 4/0 Cu/Al (Str)
3/0 - 1/0 Cu/Al (Str)
1
1-2
1-2
#1 - #6 Cu/Al
1-2
#1 - #6 Cu/Al
1-2
350kcmil - 2/0 Cu/Al (Str)
1/0 Cu/Al (Str)
1
350kcmil - 2/0 Cu/Al (Str)
1/0 Cu/Al (Str)
1
1-2
1-2
2
1-2
1-2
2
1, 2, ,3 620
1, 2, ,3 760
31.1 (275)††
56.5 (500)
2
2
31.1 (275)††
56.5 (500)
2
2
10
10
16500-_
16504-_
#1 - #4 Cu/Al
#1 - #4 Cu/Al
#6 Cu/Al
#6 Cu/Al
500kcmil - 4/0 Cu/Al (Str)
3/0 - 1/0 Cu/Al (Str)
1
500kcmil - 4/0 Cu/Al (Str)
3/0 - 1/0 Cu/Al (Str)
1
1-2
1-2
#1 - #6 Cu/Al
1-2
#1 - #6 Cu/Al
1-2
*
75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule
(customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
** Not covered by CSA certification.
See table below for the tested upstream overcurrent protective devices necessary for achieving this SCCR.
†
††ꢀTorqueꢀratingꢀforꢀdualꢀwireꢀandꢀferruleꢀapplicationꢀisꢀ30.5ꢀN•mꢀ(270ꢀLb-in).
Short-Circuit Current Rating (SCCR) data for block 16204-_:
Conductors (AWG)
Fuse class/Bussmann series symbol/ampacity
RK1
RK5
T
Catalog
number
No. of
poles
J
LPN-RK (250 V), FRN-R (250 V), JJN (300 V),
Minimum enclosure
FRS-R (600 V) JJS (600 V) SCCR size
60 200 200 kA 16 x 16 x 6.75
Lineside
Loadside
2/0 - #8
LPJ
LPS-RK (600 V)
16204-_
1, 2, 3 2/0 - #8
200
200
2
Eaton.com/bussmannseries
Splicer blocks
Technical Data 10534
Effective June 2016
Dual wire port application
Ferrule terminal application
•ꢀ
•ꢀ
Rated for dual wire port application to increase the possible
Bussmann series splicer blocks are rated for use with UL Listed
ferrules (see catalog number table for details). Ferrule ratings
apply to copper wire only.
number of lineside and loadside connections. E.g., 16303-1 can
accept two wires into the lineside port (1/0 - #6 Cu/Al) and two
wires per port (2 connections per pole total) on the loadside lug
(1/0 - #6 Cu/Al).
•ꢀ
•ꢀ
Ferrule applications allow for the use of a broader range of
conductor stranding and simulate a more efficient, solid wire
connection with the PDB terminal port.
•ꢀ
Dual wire applications are only viable when using two wires of
the same size, stranding, and insulating and conductor material in
the same port.
Always use UL Listed ferrules in accordance with the
manufacturer’s specifications and instructions.
Dimensions — in
160_ blocks
4.12" (2-Pole)
5.37" (3-Pole)
6.62" (4-Pole)
0.69"
3.62" (2-Pole)
4.87" (3-Pole)
6.12" (4-Pole)
0.25"
0.50"
Lineside
2.12"
2.75"
1.002.00"
0.38"
1.38"
Loadside
0.27" Dia. (2 holes)
Slot 0.22" x 0.38" (4 places)
162_, 163_ and 165_ blocks
C
D
F
E
E
J H
Lineside
A
G
B
L C'Bore
K Dia.
Loadside
Catalog
number
prefix
A
B
C1
C2
C3
D
E
F
G
H
J
K
L
162_
163_
165_
2.88 2.25 1.07 1.88 2.70 1.75 0.82 0.54 0.32 0.84 0.31 0.20
0.41
4.0
5.5
3.38 1.98 3.60 5.21 3.32 1.62 0.99 0.31 0.88 0.35 Slot 0.20” wide x 0.41” long Slot 0.42” wide x 0.62” long
4.75 3.11 5.76 8.48 2.94 2.69 1.55 0.36 1.19 0.44 Slot 0.20” wide x 0.33” long Slot 0.41” wide x 0.53” long
Eaton.com/bussmannseries
3
Technical Data 10534
Splicer blocks
Effective June 2016
Optional covers
Electrical safety can be enhanced by installing optional covers.
From the table below, order the cover catalog number that matches
the block catalog number.
Block catalog number
16000-2
16000-3
16000-4
16003-2
16003-3
16003-4
16005-2
16005-3
16005-4
16200-1
16200-2
16200-3
16201-1
16201-2
16201-3
16204-1
16204-2
16204-3
16301-1
16301-2
16301-3
16303-1
16303-2
16303-3
16306-1
16306-2
16306-3
16500-1
16500-2
16500-3
16504-1
16504-2
16504-3
Poles
2
Cover catalog number
CPB160-2*
CPB160-3*
CPB160-4*
CPB160-2*
CPB160-3*
CPB160-4*
CPB160-2*
CPB160-3*
CPB160-4*
CPB162-1*
CPB162-2*
CPB162-3*
CPB162-1*
CPB162-2*
CPB162-3*
CPB162-1*
CPB162-2*
CPD162-3*
CPDB-1*
3
4
2
3
4
2
3
4
1
2
3
1
2
3
1
2
3
1
2
CPDB-2*
3
CPDB-3*
1
CPDB-1*
2
CPDB-2*
3
CPDB-3*
1
CPDB-1*
2
CPDB-2*
3
CPDB-3*
1
CPDB165**
CPDB165**
CPDB165**
CPDB165**
CPDB165**
CPDB165**
2
3
1
2
3
*
Cover catalog number provides one individual cover for each block.
** Order one cover for each pole.
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once
a product has been selected, it should be tested by the user in all possible applications.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
For Eaton’s Bussmann series
Eaton.com
product information,
call 1-855-287-7626 or visit:
Eaton.com/bussmannseries
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton and Bussmann are valuable trademarks
of Eaton in the U.S. and other countries. You
are not permitted to use the Eaton trademarks
Eaton.com/bussmannseries
without prior written consent of Eaton.
Follow us on social media to get the
latest product and support information.
© 2016 Eaton
All Rights Reserved
Printed in USA
CSA is a registered trademark of the Canadian
Standards Group.
Publication No. 10534 — BU-MC16057
June 2016
UL is a registered trademark of the
Underwriters Laboratories, Inc.
Eaton.com/bussmannseries
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明